Professional Documents
Culture Documents
1/4
SYSTEM INFORMATION
System Structure
TECHNICAL INFORMATION
Reaction to Fire Bfl-S1 (DIN EN 13501-1)
2/4
APPLICATION INFORMATION
Consumption Sikafloor® MultiDur EB-24 system (~ 2–4mm)
Coating System Product Consumption
Primer 1 x Sikafloor®-156 /- ~ 0.3–0.5 kg/m²
161
Wearing coat Sikafloor®-263 SL ~ 4 kg /m2 ( 2 kg/m²
or Sikafloor®-264 filled binder + 2 kg/m² quartz
1:1 with quartz sand sand)
0.06–0.3mm
Broadcast in excess quartz sand 0.3 – 0.8 ~ 4–6 kg/m²
mm
Top coat 1–2 × Sikafloor®-264 ~0.6–0.8 kg/m²
PRODUCT INFORMATION
Packaging Please refer to the individual Product Data Sheet
Shelf Life Please refer to the individual Product Data Sheet
Storage Conditions Please refer to the individual Product Data Sheet
3/4
MAINTENANCE LOCAL RESTRICTIONS
Please note that as a result of specific local regula-
CLEANING tions the performance of this product may vary from
Please refer to the Information Manual Sikafloor®- country to country. Please consult the local Product
Cleaning Regime Data Sheet for the exact description of the application
fields.
FURTHER DOCUMENTS
ECOLOGY, HEALTH AND SAFETY
Please refer to :
▪ Sika® Information Manual Mixing & Applications of For information and advice on the safe handling, stor-
Flooring systems age and disposal of chemical products, users shall refer
▪ Sika® Information Manual Evaluation and Prepara- to the most recent Safety Data Sheet (SDS) containing
tion of Surfaces for Flooring systems physical, ecological, toxicological and other safety-re-
lated data.
LIMITATIONS
LEGAL NOTES
▪ Do not apply Sikafloor® MultiDur EB-24 on sub-
strates with rising moisture. The information, and, in particular, the recommenda-
▪ Freshly applied Sikafloor® MultiDur EB-24 must be tions relating to the application and end-use of Sika
protected from damp, condensation and water for at products, are given in good faith based on Sika’s cur-
least 24 hours. rent knowledge and experience of the products when
▪ The incorrect assessment and treatment of cracks properly stored, handled and applied under normal
may lead to a reduced service life and reflective conditions in accordance with Sika’s recommenda-
cracking. tions. In practice, the differences in materials, sub-
▪ For exact colour matching, ensure the Sikafloor®-264 strates and actual site conditions are such that no war-
in each area is applied from the same control batch ranty in respect of merchantability or of fitness for a
numbers. particular purpose, nor any liability arising out of any
▪ Under certain conditions, underfloor heating or high legal relationship whatsoever, can be inferred either
ambient temperatures combined with high point from this information, or from any written recom-
loading, may lead to imprints in the resin. mendations, or from any other advice offered. The
▪ If heating is required do not use gas, oil, paraffin or user of the product must test the product’s suitability
other fossil fuel heaters, these produce large quantit- for the intended application and purpose. Sika re-
ies of both CO2 and H2O water vapour, which may ad- serves the right to change the properties of its
versely affect the finish. For heating use only electric products. The proprietary rights of third parties must
powered warm air blower systems. be observed. All orders are accepted subject to our
current terms of sale and delivery. Users must always
refer to the most recent issue of the local Product Data
VALUE BASE Sheet for the product concerned, copies of which will
All technical data stated in this Product Data Sheet are be supplied on request.
based on laboratory tests. Actual measured data may
vary due to circumstances beyond our control.
SikafloorMultiDurEB-24_en_GB_(09-2017)_4_1.pdf