UGDC Chemical Laboratory Department

Monthly Integrity Report


Apr. 2009
Report No: Int-2009-04
Sample H2S ppm CO2 Mol% WDP °C
Sample Location CO2 Mol% WDP °C Max. value/ Max. valu
Frequency wt. as S
Month Month
Daily
El Gamil Feed Gas
(Averaged)
0.7343 <0.1 N/A 0.7741 N/A
Daily
Ha’py Feed Gas
(Averaged)
0.2770 <0.1 N/A 0.3838 N/A
Daily
Feed Mix
(Averaged)
0.6852 <0.1 +7.27 0.6944 +10.20
Daily
D/S Dehydration
(Averaged)
0.6874 <0.1 -77.63 0.6983 -74.60
Chlorides
H2O wt %
ppm
Liquid from Inlet Separator 02-V-01 Monthly No level in the inlet separator
Coalescer (2)Liquid from

Pre-Filter 03-LV-20 8.90 387.5


03-F-05
03-LV-23 8.78 290.0
03-LV-30 9.35 220.0
Monthly
Filter
Coalescer
03-F-06 03-LV-26 8.20 242.0

Chlorides Mercaptan
H2O wt %
ppm ppm-wt
Cold Drain Drum Liquid 96-V-02 Monthly No level
Warm Drain Drum Liquid 96-V-01 Monthly 8.56 50.69 8.5
H2O ppm- Acid No.
BS&W ml
wt mg KOH/g

Hot Oil Quarter 112 0.068 <0.025

H2O ppmv.

Absorber Bottoms Yearly ---


TDS ppm pH

Outlet Regen Gas KO Drum 03-V-03 Every 2 Months 75 4.42


Remarks:
(1) All the samples were collecting from new filter coalescor drains & were one phase.

Date: 7/05/2009
Hesham Hashim
UGDC Chemical Laboratory Department