You are on page 1of 3

Integrated Membranes Solutions Design Software, 2018

Created on: 14/7/2020 11:21:38

Concentrate Recirculation
Project name GSL 5TPD Page : 1/3
Calculated by Jugal Permeate flow/train 0.20 m3/h
HP Pump flow 0.89 m3/h Raw water flow/train 0.67 m3/h
Feed pressure 50.3 bar Permeate recovery 22.47 %
Feed temperature 25.0 °C(77.0°F) Total system recovery 30.00 %
Concentrate recirculation 0.22 m3/h Element age 3.0 years
Feed water pH 7.03 Flux decline %, first year 7.0
Chem dose, mg/l, - None Fouling factor 0.88
Specific energy 7.74 kwh/m3 SP increase, per year 10.0 %
Pass NDP 13.3 bar
Average flux rate 13.4 lmh
Feed type Sea Surface Conventional

Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 0.2 0.9 0.7 13.4 0.1 16.3 1.05 0 0 50.2 496.7 SWC5-LD-4040 2 1 x 2M
Ion (mg/l) Raw Water Feed Water Permeate Water Concentrate 1
Hardness, as CaCO3 0.00 0.00 0.000 0.0
Ca 0.00 0.00 0.000 0.0
Mg 0.00 0.00 0.000 0.0
Na 14000.00 15460.24 195.515 19907.6
K 0.00 0.00 0.000 0.0
NH4 0.00 0.00 0.000 0.0
Ba 0.000 0.000 0.000 0.0
Sr 0.000 0.000 0.000 0.0
H 0.00 0.00 0.001 0.0
CO3 0.00 0.00 0.000 0.0
HCO3 0.11 0.12 0.003 0.2
SO4 0.00 0.00 0.000 0.0
Cl 22000.00 24295.64 301.337 31286.4
F 0.00 0.00 0.000 0.0
NO3 0.00 0.00 0.000 0.0
PO4 0.00 0.00 0.000 0.0
OH 0.01 0.01 0.000 0.0
SiO2 0.00 0.00 0.000 0.0
B 0.00 0.00 0.000 0.0
CO2 0.01 0.01 0.01 0.01
NH3 0.00 0.00 0.00 0.00
TDS 36000.11 39756.00 496.86 51194.23
pH 7.03 7.06 5.88 7.15

Saturations Raw Water Feed Water Concentrate Limits


CaSO4 / ksp * 100, % 0 0 0 400
SrSO4 / ksp * 100, % 0 0 0 1200
BaSO4 / ksp * 100, % 0 0 0 10000
SiO2 saturation, % 0 0 0 140
CaF2 / ksp * 100, % 0 0 0 50000
Ca3(PO4)2 saturation index 0.0 0.0 0.0 2.4
CCPP, mg/l 0.00 0.00 0.00 850
Ionic strength 0.61 0.68 0.87
Osmotic pressure, bar 28.5 31.4 40.5

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.228.87 %

Email : imsd-support@hydranauticsprojections.net
Integrated Membranes Solutions Design Software, 2018

Created on: 14/7/2020 11:21:38

Concentrate Recirculation
Project name GSL 5TPD Page : 2/3
Calculated by Jugal Permeate flow/train 0.20 m3/h
HP Pump flow 0.89 m3/h Raw water flow/train 0.67 m3/h
Feed pressure 50.3 bar Permeate recovery 22.47 %
Feed temperature 25.0 °C(77.0°F) Total system recovery 30.00 %
Concentrate recirculation 0.22 m3/h Element age 3.0 years
Feed water pH 7.03 Flux decline %, first year 7.0
Chem dose, mg/l, - None Fouling factor 0.88
Specific energy 7.74 kwh/m3 SP increase, per year 10.0 %
Pass NDP 13.3 bar
Average flux rate 13.4 lmh
Feed type Sea Surface Conventional
Pass - Perm. Flow / Vessel Flux DP Flux Beta Stagewise Pressure Perm. Element Element PV# x
Stage Flow Feed Conc Max Perm. Boost Conc TDS Type Quantity Elem #
m3/h m3/h m3/h lmh bar lmh bar bar bar mg/l
1-1 0.2 0.9 0.7 13.4 0.1 16.3 1.05 0 0 50.2 496.7 SWC5-LD-4040 2 1 x 2M

Permeate Permeate
Pass - Element Feed Pressure Conc NDP Water Water Beta Permeate (Stagewise cumulative)
Stage no. Pressure Drop Osmo. Flow Flux TDS Ca Mg Na Cl
bar bar bar bar m3/h lmh
1-1 1 50.3 0.06 36.4 15 0.1 16.3 1.05 385.2 0 0 151.575 233.612
1-1 2 50.2 0.05 40.5 10.5 0.1 10.5 1.04 496.7 0 0 195.469 301.266

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.228.87 %

Email : imsd-support@hydranauticsprojections.net
Integrated Membranes Solutions Design Software, 2018

Created on: 14/7/2020 11:21:38

Concentrate Recirculation
Project name GSL 5TPD Page : 3/3
Temperature : 25.0 °C Element age, P1 : 3.0 years

Stream No. Flow (m3/h) Pressure (bar) TDS (mg/l) pH Econd (µs/cm)
1 0.670 0 36000 7.03 54978
2 0.890 0 39756 7.06 60370
3 0.890 50.3 39756 7.06 60370
4 0.690 50.2 51194 7.15 76653
5 0.220 0 51194 7.15 76653
6 0.470 0 51194 7.15 76653
7 0.200 0 497 5.88 1124

Product performance calculations are based on nominal element performance when operated on a feed water of acceptable quality. The results shown on the printouts produced by this program are
estimates of product performance. No guarantee of product or system performance is expressed or implied unless provided in a separate warranty statement signed by an authorized Hydranautics
representative. Calculations for chemical consumption are provided for convenience and are based on various assumptions concerning water quality and composition. As the actual amount of chemical
needed for pH adjustment is feedwater dependent and not membrane dependent, Hydranautics does not warrant chemical consumption. If a product or system warranty is required, please contact your
Hydranautics representative. Non-standard or extended warranties may result in different pricing than previously quoted. Version : 2.228.87 %

Email : imsd-support@hydranauticsprojections.net