MISR UNIVERSITY FOR SCIENCE AND TECHNOLOGY
FACULTY OF ENGINEERING
ELECTRICAL POWER AND MACHINES DEPARTMENT

Industrial Electronics
PME 414
HOMEWORK Exam. #1
Relay logic can be used to control the extension and retraction of a pneumatic (air)
cylinder. The figure shows a drill press that uses an air cylinder to move a drill up
and down through its drilling cycle. The cycle begins with the drill at the top of its
stroke. The air cylinder is retracted and the drill motor is turned off. When the start
button is depressed momentarily, the extend solenoid is energized and retract
solenoid is de-energized so that air is moved to the air cylinder to make it extend,
which causes the drill to move down. The drill motor is turned on by the drill motor
starter during the down stroke. When the drill is extended to its full down stroke, it
will strike a limit switch that will open and cause the retract solenoid to be de-
energized, and the cylinder retracts moving the drill back to the up position.
REQUIRED:
THE RELAY LOGIC THAT IS USED TO CONTROL THE EXTENSION AND
THE RETRACTION OF THE AIR CYLINDER TO MOVE A DRILL
THROUGH ITS STROKE.
In the relay logic diagram:
- Limit switch LS1 is NO
- Limit switch LS2 is NC
- Three control relays can be used CR1, CR2, CR3
- Two solenoids , Extend SOL and Retract SOL
- One motor starter Drill motor starter.