You are on page 1of 1

Design calculation sheet

Project no: Date: Sheet no.: 1 of 1 Computed by:

Subject: Residential Avenue Checked by:

ROOF-Rain water drainage -Corner RA-10 Approved by:

A x R x 0.0104
GPM = 6383 0.75 x 0.0104 => GPM = 49.8

A x R / 3600
L/S = 593 x 19.05 / 3600 => L/S = 3

R = Rainfall Intensity in ("/hr) in gpm formula or (mm/hr) in metric formula


A = Roof Area in (ft2) in gpm formula or (m2) in metric formula

Selection :

Roof Drain Vertical Leader Requirements for Horizontal


Roof Areas at Various Rainfall Rate
Hourly Rainfall in Inches
Leaders 1 11/2 2 21/2 3 4 5 6 7 8
Pipe Size Roof Area Sq. Ft.
2" 50 2,880 1,920 1,440 1,150 960 720 575 480 410 360
3" 82 8,880 5,860 4,400 3,520 2,930 2,200 1,760 1,470 1,260 1,100
4" 110 18,400 12,700 9,200 7,360 6,130 4,600 3,680 3,070 2,630 2,300
5" 125 34,600 23,050 17,300 13,840 11,530 8,650 6,920 5,765 4,945 4,325
6" 150 54,000 36,000 27,000 21,600 18,000 13,500 10,800 9,000 7,715 6,750
8" 200 116,000 77,400 58,000 46,400 38,680 29,000 23,200 19,315 16,570 14,500
Hourly Rainfall in mm
Leaders 25 40 50 65 75 100 125 150 175 200
Pipe Size Roof Area Sq. mt.
2" 50 268 178 134 107 89 67 53 45 38 33
3" 82 825 545 409 327 272 204 164 137 117 102
4" 110 1,710 1,180 855 684 570 428 342 285 244 214
5" 125 3,216 2,143 1,608 1,286 1,072 804 643 536 460 402
6" 150 5,019 3,346 2,510 2,008 1,673 1,255 1,004 837 717 627
8" 200 10,782 7,194 5,391 4,313 3,595 2,696 2,156 1,795 1,540 1,348
Table 1

ALLOWABLE FLOW
Horizontal Storm Drain Slope per Foot
Pipe Size Vertical Leaders 1/8" (1%) 1/4" (2%) 1/2" (4%)
Inches mm GPM L/S GPM L/S GPM L/S GPM L/S
2" 50 30 2 12 1 17 1 24 2
3" 82 90 6 36 2 51 3 72 5
4" 110 192 12 78 5 111 7 157 10
5" 125 348 22 142 9 201 13 284 18
6" 150 566 36 231 15 327 21 462 29
8" 200 1220 77 498 31 705 44 996 63
10" 250 2200 139 902 57 1275 80 1804 114
12" 300 - - 1467 92 2076 131 2934 185
15" 375 - - 2666 168 3774 238 5332 336
Table 2
No. or risers required = 4