This document provides specifications for a heat exchanger including:
- Dimensions of 10 x 102.36 inch unit with 93.794 square feet of surface area
- Performance details like inlet/outlet temperatures and pressures for the shell and tube sides
- Construction details such as materials, pipe sizes, baffle spacing, and code requirements
- Weight and remarks section
This document provides specifications for a heat exchanger including:
- Dimensions of 10 x 102.36 inch unit with 93.794 square feet of surface area
- Performance details like inlet/outlet temperatures and pressures for the shell and tube sides
- Construction details such as materials, pipe sizes, baffle spacing, and code requirements
- Weight and remarks section
This document provides specifications for a heat exchanger including:
- Dimensions of 10 x 102.36 inch unit with 93.794 square feet of surface area
- Performance details like inlet/outlet temperatures and pressures for the shell and tube sides
- Construction details such as materials, pipe sizes, baffle spacing, and code requirements
- Weight and remarks section
Released to the following HTRI Member Company: US Units
PT. AIR SURYA RADIATOR MADE WIDANA Job No. Customer PT. PERTAMINA EP Reference No. Address SUBANG FIELD - PERTAMINA EP ASSET 3 Proposal No. Plant Location SP BAMBU BESAR Date 3/23/2021 Rev Service of Unit HEAT EXCHANGER (BBS-HE-101) Item No. Size 10 x 102.36 inch Type BEM Horizontal Connected In 1 Parallel 1 Series Surf/Unit (Gross/Eff) 93.794 / 90.243 ft2 Shell/Unit 1 Surf/Shell (Gross/Eff) 93.794 / 90.243 ft2 PERFORMANCE OF ONE UNIT Fluid Allocation Shell Side Tube Side Fluid Name COOLING WATER FEED GAS Fluid Quantity, Total lb/hr 26501 11745 Vapor (In/Out) 11744 11320 Liquid 26501 26501 0.8442 424.29 Steam 30.020 8.4283 Water 0.2943 22.428 Noncondensables 0.0561 0.0561 Temperature (In/Out) F 44.60 53.60 120.00 77.00 Specific Gravity 1.0013 1.0002 0.9907 0.6374 Viscosity cP 1.4247 1.2339 0.0134 V/L 0.5519 0.0127 V/L 0.1982 Molecular Weight, Vapor Molecular Weight, Noncondensables Specific Heat Btu/lb-F 1.0112 1.0102 0.3565 V/L 1.0097 0.3558 V/L 0.5702 Thermal Conductivity Btu/hr-ft-F 0.3335 0.3385 0.0139 V/L 0.3658 0.0125 V/L 0.0799 Latent Heat Btu/lb 481.31 128.30 Inlet Pressure psia 64.696 419.70 Velocity ft/sec 1.17 13.07 Pressure Drop, Allow/Calc psi 5.000 0.812 5.000 0.779 Fouling Resistance (min) ft2-hr-F/Btu 0.00102 0.00102 Heat Exchanged 244424 Btu/hr MTD (Corrected) 45.7 F Transfer Rate, Service 59.23 Btu/ft2-hr-F Clean 77.19 Btu/ft2-hr-F Actual 65.78 Btu/ft2-hr-F CONSTRUCTION OF ONE SHELL Sketch (Bundle/Nozzle Orientation) Shell Side Tube Side Design/Test Pressure psig 75.000 / 97,5 500.00 / 650 Design Temperature F 100.00 165.00 No Passes per Shell 1 2 Corrosion Allowance inch 0.1250 0.1250 Connections In inch 1 @ 2.9000 1 @ 3.8260 Size & Out inch 1 @ 2.9000 1 @ 3.8260 Rating Intermediate @ @ Tube No. 42 OD 1.0000 inch Thk(Avg) 0.0830 inch Length 8.530 ft Pitch 1.2500 inch Tube Type Plain Material SA-213 TP316 Tube (S) S31600 Tube pattern 30 Shell SA-106 B Pipe (S) K03006 ID 10.000 OD 10.750 inch Shell Cover SA-516 70 Pl. K02700 Channel or Bonnet SA-106 B Pipe (S) K03006 Channel Cover SA-516 70 Pl. K02700 Tubesheet-Stationary SA-516 70 Pl. K02700 Tubesheet-Floating Floating Head Cover Impingement Plate None Baffles-Cross Carbon steel Type Single-Seg. %Cut (Diam) 32 Spacing(c/c) 5.9812 Inlet 7.3750 inch Baffles-Long Seal Type None Supports-Tube U-Bend Type None Bypass Seal Arrangement pairs seal strips Tube-Tubesheet Joint Expanded (2 grooves) Expansion Joint Type None Rho-V2-Inlet Nozzle 412.22 lb/ft-sec2 Bundle Entrance 276.94 Bundle Exit 277.23 lb/ft-sec2 Gaskets-Shell Side Spiral Wound Metal (SS) Tube Side Spiral Wound Metal (SS) - Floating Head Spiral Wound Metal (SS) Code Requirements ASME TEMA Class R Weight/Shell 1323.3 lb Filled with Water 1648.0 lb Bundle 372.76 lb Remarks: