DESIGN OF ONE WAY SLAB CANTILEVER
PROJECT: WHALEN UY RESIDENCES DEFLECTION CHECK: Grade 40 Grade 60
TITLE : 2CS-1 L/360 Actual W 7.258487 0.002 0.0018
2.083333 0.032598 Ig 1.63E+08 B 1000 1000
DESIGN PARAMETERS Ie 81380208 T 125.00 125.00
Pass
F'c = 20.69 MPa = 3.00 ksi 4700of f'c 21375.96 As 250 225
Fy = 275.80 MPa = 40 ksi Diameter 10 12.00
Length (L) = 0.50 m OEC SS BEC CANT 78.53982 113.0973
Minimum thickness of slab if M 14 8 16 2
Simply supported (L) = 25.00 mm ~ 50.00 mm C 10 10 11 2
One end continous (L) = 20.83 mm ~ 25.00 mm D 24 24 11 2 spacing 314.1593 502.6548
Both ends continous (L) = 17.86 mm ~ 25.00 mm
Cantilever (L) = 50.00 mm ~ 50.00 mm
Diameter of bar = 10.00 mm
Depth (d) = 100.00 mm
t = 125.00 mm
b = 1,000.00 mm
LOADINGS
Dead Load
Imposed load (Factored) = 7.63 KPa 1.2 3.36 Add'l Load
Live Load (Factored) = 3.07 KPa 1.6 1.92
Total Moment including / Mom constant
@ midspan / 2 = 1.34 KN-m 0.19 128/9
@ continous end / 2 = 1.34 KN-m 0.33 8
@ discontinous end / 2 = 1.34 KN-m 0.06 h31/3
Required rho
rho required @ midspan = 0.00054134
rho required @ continous end = 0.00054134
rho required @ discontinous end = 0.00054134
Reinforcement compare to temp. required
As required @ midspan = 54.13 mm² < 225.00 mm²
As required @ continous end = 54.13 mm² < 225.00 mm²
As required @ discontinous end = 54.13 mm² < 225.00 mm²
using dia. 10.00 mm A= 78.54 mm²
Steel reinforcement
spacing @ midspan = 349.07 mm > 300.00 mm
spacing @ continous end = 349.07 mm > 300.00 mm
spacing @ discontinous end = 349.07 mm > 300.00 mm
adopt
@ midspan = 10.00 mm @ 300.00 mm o.c.
@ continous end = 10.00 mm @ 300.00 mm o.c.
@ discontinous end = 10.00 mm @ 300.00 mm o.c.