Whalen Uy Residences 2CS-1 125.00 125.00 3.00 Ksi 40 Ksi 10 12.00 0.50 M

This document provides design parameters and calculations for the reinforcement of a one-way cantilever slab. The slab has a length of 0.5m, thickness of 125mm, and width of 1000mm. Design parameters include a concrete compressive strength of 20.69MPa and steel yield strength of 275.80MPa. Loads on the slab include dead loads of 7.63kPa and factored live loads of 3.07kPa. Calculations determine the required reinforcement ratios and areas at different points on the slab, as well as proposed bar sizes and spacing to meet the requirements.

Uploaded by

William Provido
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
164 views1 page

Whalen Uy Residences 2CS-1 125.00 125.00 3.00 Ksi 40 Ksi 10 12.00 0.50 M

This document provides design parameters and calculations for the reinforcement of a one-way cantilever slab. The slab has a length of 0.5m, thickness of 125mm, and width of 1000mm. Design parameters include a concrete compressive strength of 20.69MPa and steel yield strength of 275.80MPa. Loads on the slab include dead loads of 7.63kPa and factored live loads of 3.07kPa. Calculations determine the required reinforcement ratios and areas at different points on the slab, as well as proposed bar sizes and spacing to meet the requirements.

Uploaded by

William Provido
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

DESIGN OF ONE WAY SLAB CANTILEVER

PROJECT: WHALEN UY RESIDENCES DEFLECTION CHECK: Grade 40 Grade 60


TITLE : 2CS-1 L/360 Actual W 7.258487 0.002 0.0018
2.083333 0.032598 Ig 1.63E+08 B 1000 1000
DESIGN PARAMETERS Ie 81380208 T 125.00 125.00
Pass
F'c = 20.69 MPa = 3.00 ksi 4700of f'c 21375.96 As 250 225
Fy = 275.80 MPa = 40 ksi Diameter 10 12.00
Length (L) = 0.50 m OEC SS BEC CANT 78.53982 113.0973
Minimum thickness of slab if M 14 8 16 2
Simply supported (L) = 25.00 mm ~ 50.00 mm C 10 10 11 2
One end continous (L) = 20.83 mm ~ 25.00 mm D 24 24 11 2 spacing 314.1593 502.6548
Both ends continous (L) = 17.86 mm ~ 25.00 mm
Cantilever (L) = 50.00 mm ~ 50.00 mm
Diameter of bar = 10.00 mm
Depth (d) = 100.00 mm
t = 125.00 mm
b = 1,000.00 mm

LOADINGS
Dead Load
Imposed load (Factored) = 7.63 KPa 1.2 3.36 Add'l Load
Live Load (Factored) = 3.07 KPa 1.6 1.92

Total Moment including / Mom constant


@ midspan / 2 = 1.34 KN-m 0.19 128/9
@ continous end / 2 = 1.34 KN-m 0.33 8
@ discontinous end / 2 = 1.34 KN-m 0.06 h31/3

Required rho
rho required @ midspan = 0.00054134
rho required @ continous end = 0.00054134
rho required @ discontinous end = 0.00054134

Reinforcement compare to temp. required


As required @ midspan = 54.13 mm² < 225.00 mm²
As required @ continous end = 54.13 mm² < 225.00 mm²
As required @ discontinous end = 54.13 mm² < 225.00 mm²

using dia. 10.00 mm A= 78.54 mm²


Steel reinforcement
spacing @ midspan = 349.07 mm > 300.00 mm
spacing @ continous end = 349.07 mm > 300.00 mm
spacing @ discontinous end = 349.07 mm > 300.00 mm

adopt
@ midspan = 10.00 mm @ 300.00 mm o.c.
@ continous end = 10.00 mm @ 300.00 mm o.c.
@ discontinous end = 10.00 mm @ 300.00 mm o.c.