Spyder Raking SRM 2 4 Assembly Manual 1 4
Spyder Raking SRM 2 4 Assembly Manual 1 4
12
7
10
11
4
3
2
1
13 B18.2.3.1M - Hex cap screw, M8 x M8 x 40mm Bolt for Splice 4 10 ft/lbs 40mm
AW SRM 2.4 Assembly Manual
0
1.25 x 40 --40N
14 Metal Roof Foot Gasket Rubber Mounting Gasket 8
(Metal Roof's Only) SCALE: 1:18 SHEET 1 OF 8
5 4 3 2 1
Mounting Foot to SRM Rail 2
Note:
14
The bolt hole on the foot Note:
must ALWAYS be on the
high end of the slope. Rubber Foot Gasket only
applies to metal roof's. It is not tel: 905-532-0770 520 Applewood Cresent
required for asphalt roof's. fax: 905-532-0593 Vaughan ON, L4K 4B4
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
ITEM PART NUMBER DESCRIPTION QTY THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
NO. PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
1 SRM EXTRUDE 2.4 Spyder Rail (10', 17', 20') 2 AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
4 SRM FOOT 1.0 Aluminum Foot 8
B18.2.3.4M - Hex flange screw, DWG. NO. REV
5 M8 x 1.25 x 16 --16N M8 x 16mm Serrated Flange Bolt 8 Drawn By
At MAX height,
minimum engagement
for teeth on foot to be 2
Note:
Depending where the SRM Foot
lands, it may need to be trimmed
at minimum height.
www.sentinelsolar.com
2.98" MAX
5.15" MAX
1.25" MIN
3.41" MIN
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
Drawn By
DWG. NO. REV
AW SRM 2.4 Assembly Manual
0
Bottom of Rail Bottom of Module
SCALE: 1:1 SHEET 3 OF 8
5 4 3 2 1
Foot Placement 4
Refer to Module
Specifications
36-48"
To match
purlin/strapping
spacing, if applicable.
48" 24"
Note: Actual dimensions to match truss spacing
tel: 905-532-0770 520 Applewood Cresent
If truss spacing is less than 36", foot fax: 905-532-0593 Vaughan ON, L4K 4B4
placement can be staggered as
shown. Anymore than 36", every www.sentinelsolar.com
truss/blocking must be used.
PROPRIETARY AND CONFIDENTIAL
EVERY TRUSS UNDER THE SOLAR THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
SYSTEM IS TO BE PENETRATED PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
Drawn By
DWG. NO. REV
AW SRM 2.4 Assembly Manual
0
SCALE: 1:15 SHEET 4 OF 8
5 4 3 2 1
Mounting Inverters 5
7
10
Note:
WEEB washer is optional, grounding
8 the inverter can also be done using
a #6 bare copper wire or what is
recommended by electrician.
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
ITEM PART NUMBER DESCRIPTION QTY AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
NO. Sentinel Solar IS PROHIBITED.
7 Enphase M 215 Inverter 3
DWG. NO. REV
8 Weeb SMC Grounding WEEB Washer 3 Drawn By
Note:
This only applies if there are additional rows
and therefore may not apply to all systems.
40.00 21.5
May differ depending on module
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Solar. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
These dimensions are approximate. The 21.5" from the Sentinel Solar IS PROHIBITED.
end of the rail includes a 2.25" space so that the first
panel does not sit at the edge of the rail. Drawn By
DWG. NO. REV
Inverters mount so they are approximately centered AW SRM 2.4 Assembly Manual
0
under their corresponding panel.
SCALE: 1:20 SHEET 6 OF 8
5 4 3 2 1
Installing Modules 7
Note:
Dual and Single module
clamps use this 'ClicLoc'
connection system.
A
As the bolt tightens, the 'bell'
raises and spreads the claws
which then grab the rail.
Be sure to keep all the panels Torque to 5 ft/lbs
flush at the ends and
centered between the rails.
12
10
11
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
SCALE 1 : 10 ITEM
AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
Sentinel Solar IS PROHIBITED.
2 6
Building your own splice can be done by THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF Sentinel Power Sysetms Inc. ANY REPRODUCTION IN
using any off-cut piece of rail and drilling 2
PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
holes with the use of the groove in the Sentinel Solar Corp. ISPROHIBITED.
channel as a guide.
Drawn By
DWG. NO. REV
AW Splice Assembly 2.4
0
SCALE: 1:5 SHEET 1 OF 1
5 4 3 2 1
Asphalt Roof Installation 10
Foot Detail
Optional flashing kit can be used as added
protection over mounting foot and lag screws.
An appropriate sealant/adhesive is to be used
to secure the flashing to the roof.
1.
00
Use rubber backed washer to seal
bolt head to top of mounting foot
Use an appropriate
sealant/adhesive to seal foot
to roof surface
Use 5/16" x 3" galvanized lag screws
to secure mounting foot to roof.
Minimum thread length of 2"
Roof Sheeting
Roof Truss
tel: 905-532-0770 520 Applewood Cresent
fax: 905-532-0593 Vaughan ON, L4K 4B4
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
Use 5/16" x 3" galvanized lag screws Height of panels can be fully
to secure mounting foot to roof. adjusted for height differences
Minimum thread length of 2" in the roof along the length of
the rail. Height variance of
Minimum engagement of 2" into approximately 1 3/4" is
roof truss, blocking, or purlins. possible.
If blocking is used, it is to match top
cord.
Use rubber backed washer to seal
bolt head to top of mounting foot
Roof Sheeting
www.sentinelsolar.com
PROPRIETARY AND CONFIDENTIAL
1 4
2 5
24.0 48.0
11.0 48.0
1 2 4 5
24.0 48.0
3.0 1 2 4 5
48.0
24.0 48.0
6.0 1 3 1 6 7
48.0