cua 21a, sv 0) < } Ur U-Covalence | Spesaty Maes Cop. | PROCEDURE QUALIFICATION AND TESTING OF HEAT SHRINK SLEEVE | | PPS120 FOR BUMI, BULAN, SURIYA WELLHEAD PLATFORMS, GAS | | COMPRESSION MODULE AND { BMA-CKR, SYA-CKR, BLA-CKR PIPELINES OF CARIGALI-HESS OPERATING COMPANY SDN BHD i Saipem BMA, BLA, SYA 0, | Eat GAS FIELD DEVELOPMENT PROJECT | O=Covalence \_/Spesiaty Materials Corn | Location: PPSC Yard, Kuantan, Malaysia People present: 1. James Nelson ~ CHOC 2. smal - CHOC. 3. Ezaddin - Kencana 4. Parkidas Benedict ~ Salpem 5. Manjoor Sahib Hussein - HMIS Coorperation 8 Haironi Talib ~ HMS Cooreration 7. Eddy Alaerts — Covalence 8. Rejeev Sharma ~ Covalence APPLICATION Batch no of sleeve: GO7074 Installation of PPS120M Sleeve was carried out on 20° 3LPP coated pipe as per the Field Joint POT Procedure (HSS), document no: BBS-FJC-PR-0002, Testing: 1. "Holiday Detection Test ~was carried out at 1SkV. The sleeve passed ine same, 2. Peel Test~3 peel test was cairied out and the values are as follows: Beal vaive (Ibsinch) 57.5 80 1 575 i Equiament 41. Type of Temperature Gauge: Flukes1 Calibration valcty date: November 2007 2. Type of Peel Gauge: SalteriMeti Calibration validity date: November 2007 3, Holiday Detector. SPY 760-1400 Registration No: PPSC/QC/SHD/009 Witness S80GK & zanat sn, Coating Inspecoe Kencana HL Witnessed by: exles|oz | fe i Saipem