You are on page 1of 54

Case Studies of Soft-Story Retrofits Using

Different Design Guidelines


SEAONC Special Projects Initiative Report
By
Jonathan Buckalew, Bruce Maison, Brian McDonald,
Marko Schotanus, and David McCormick
December 2015

ABSTRACT
San Francisco has passed a mandatory retrofit ordinance targeting multi-unit soft, weak, or
open front (SWOF) buildings. Ordinance 66-13 allows use of multiple guidelines. It is up to the
structural engineer to work with the building owner and decide which of these guidelines to
use. Unfortunately, it is not possible for a practicing engineer to evaluate the merits of each
guideline within the scope of a typical SWOF retrofit project. This may result in choosing a
guideline based on prior familiarity or perceived ease of use.

The goal of this study is to illustrate the outcomes of using these different guidelines on retrofit
case studies based on Ordinance 66-13. In this way engineers can be better informed when
advising their clients. First, the study retrofits two sample buildings to three of the
methodologies allowed by San Francisco’s Ordinance: ASCE 41-13, IEBC A4, and the recently
released FEMA P807. The second part of the project provides insight into the FEMA P807
guideline by evaluating the ASCE 41-13 and IEBC A4 retrofits using P807. Lastly, the retrofits are
analyzed by computer (SAPwood) and collapse fragility curves developed using incremental
dynamic analyses. These curves quantify how each retrofit reduces the sample building’s
probability of collapse.

While the different guidelines may satisfy the ordinance, this study found that they produce
retrofits that can vary significantly. For the two sample buildings, based on static push-over
curves, the lateral strength required by FEMA P807 is significantly smaller than that required by
ASCE 41-13 and IEBC A4.The ASCE 41 and IEBC A4 retrofits were not controlled by strength
checks alone, but required additional strength in order to meet certain demand-to-capacity
ratios (for ASCE-41: D/C < 3 to allow use of linear static procedures), and story drift
requirements (IEBC A4). However, it was found that even without these additional checks, the
retrofit strength required by P-807 was still significantly less than those from ASCE-41 and IEBC
A4. This study can be used to better understand the different guidelines and help select the one
that best suits their client’s objective.

1
Contents
1. Acknowledgement and Disclaimer
2. Introduction
3. Special Projects Initiative Overview
4. Guideline Comparison
5. Analysis and Retrofit Assumptions
6. Building 1 Results
7. Building 2 Results
8. Incremental Dynamic Analyses
9. Conclusions

Appendix A – SAPwood Material Backbone Curves


Appendix B – SAPwood Pushover Curves

2
1. ACKNOWLEDGEMENT AND DISCLAIMER

This study was undertaken as the 2013 Special Projects Initiative of the Structural Engineers
Association of Northern California (SEAONC). SEAONC’s Special Projects Initiative is intended to
provide financial support for innovative projects that will serve SEAONC and its members
through initiatives that improve and promote structural engineering practice.

All opinions and conclusions expressed herein are solely those of the authors. While the
information presented in this document is believed to be correct, neither the author, nor
SEAONC, its Board, committees, editors, or individuals who have contributed to this document
make any warranty, expressed or implied, or assume any legal liability or responsibility for the
use, application of, and/or reference to opinions, findings, conclusions, or recommendations
expressed herein. The material presented in this document should not be used or relied upon
for any specific application without competent examination and verification of its accuracy,
suitability, and applicability by qualified professionals. Users of information from this document
assume all liability arising from such use.

3
2. INTRODUCTION

Soft, weak, or open front (SWOF) wood structures might pose a significant threat to public
safety. As cities and government organizations work to identify these buildings, structural
engineers must be ready to provide expertise on how to best mitigate these potentially
dangerous buildings. San Francisco has initiated a mandatory retrofit program that has three
methodologies that can be used.

The first is ASCE 41-13 “Seismic Evaluation and Retrofit of Existing Buildings” (ASCE 41-13). It is
a comprehensive standard for retrofitting buildings to meet various performance objectives,
but it is not written explicitly for SWOF structures (Ordinance 66-13 has modifications to ASCE
41 such as restricting upgrades to the first story only). The second is Appendix Chapter A4 of
the “2012 International Existing Building Code” (IEBC A4-12), which uses simplified procedures
that focus on eliminating the soft/weak story irregularity. IEBC A4 is not intended for evaluation
of the expected performance of an existing structure.

The last option that recently became available (published in 2012) to structural engineers is
FEMA P807/ ATC 71-1 – “Seismic Evaluation and Retrofit of Multi-Unit Wood-Frame Buildings
with Weak First Stories” (FEMA P807). FEMA P807 does not require the designer to perform an
explicit structural analysis, but instead relies on regression equations created from thousands
of nonlinear response history analyses performed on (hypothetically) similar models. The
regression equations are intended to be used in lieu of a nonlinear analysis.

Motivation for this project comes from Ordinance 66-13 from San Francisco. Ordinance 66-13
allows use of multiple retrofit guidelines, each with their own design criteria and unique
performance objectives. It is up to the structural engineer and building owner to decide which
of these guidelines to use. Unfortunately, it is not possible for a practicing engineer to evaluate
the merits of each guideline within the scope of a typical SWOF retrofit project (e.g. performing
trial designs with each). This often results in choosing a guideline based on prior familiarity or
perceived ease of use.

4
3. SPECIAL PROJECTS INITIATIVE OVERVIEW

The goal of this project is to assist engineers by providing a basis by which the guidelines can be
judged so as to best suit the client’s objectives. Two buildings are used for this project. Building
1 is a typical midblock SWOF building from the pre-war era (before 1930). It is a three-story
structure with retail on the ground floor and apartments on the top two floors. Building 2 is a
corner building similar to the corner buildings that failed in the Marina District of San Francisco
during the Loma Prieta Earthquake. It is a four-story building with parking on the first floor and
apartments on the upper three floors. The project is organized into three parts.

The first part is a retrofit comparison, where in each building was retrofitted to satisfy the
provisions of the three guidelines specified in Ordinance 66-13.

The second part is a benchmarking comparison, where each retrofit was evaluated using the
FEMA P807 guideline. FEMA P807 is a new guideline that has not yet been widely tested. This
benchmarking will establish where an ASCE41-13 and IEBC A4-12 retrofits fall on the FEMA
P807 spectrum. A quantitative comparison, based on a common evaluation method, can be
made from the results of this section.

The last part of the project evaluates each retrofit using nonlinear incremental dynamic analysis
(IDA). The retrofits were modeled using the NEES software Seismic Analysis Program for
Woodframe structures (SAPWood1). Results from the IDAs were used to create collapse fragility
curves. The performance of each retrofit was quantified based on building collapse, not
probability of exceeding a drift limit used in the FEMA P807 methodology.

It must be emphasized that all analyses necessitate numerous assumptions in the computer
models that have a direct influence on results. In particular, there is currently no industry
consensus on the load-drift (backbone) curves for many of the materials found in wood-frame
buildings. P-807, SAPWood, and ASCE 41-13 prescribe backbone curves that differ significantly,
and a recent review indicates all of these might be conservative2.

1
John van de Lindt; Shiling Pei (2010), "SAPWood," https://nees.org/resources/sapwood.
2
Maison, B., McDonald, B., McCormick, D., Schotanus, M., and Buckalew, J., 2014. Commentary on FEMA P-807 for
Retrofit of Wood-Frame Soft-Story Buildings, Earthquake Spectra, Vol. 30, No. 4, November.

5
4. GUIDELINE COMPARISON

The following sections outline key differences between the three guidelines as used in this
study. All comparisons below are based on the linear static methods used to retrofit the sample
buildings. Both case study buildings had SWOF conditions in their first story. Note that
Ordinance 66-13 uses the terminology “target story” to identify the portion of the building that
requires evaluation or retrofit. For this report the terms “ground floor” or “first level” are used
in lieu of “target story”.

4.1 Guideline Overview

ASCE 41-13 ASCE 41-13 is a comprehensive standard used to evaluate and retrofit
existing structures. It is intended for all building sizes and type.
IEBC A4 IEBC A4-12 is a prescriptive retrofit code created specific for wood frame
structures with a soft, weak, or open front. A4 gives no credit to existing
vertical elements that are not sheathed with structural panels.
FEMA P807 FEMA P807 is a new retrofit guideline that utilizes a performance-based
engineering approach. It relies on results from numerous nonlinear analyses
as contained in regression equations to evaluate the strength of a soft story
building. P807 was not put through an industry consensus process like ASCE
41.
Table 4.1 – Ordinance 66-13 Guideline Overview

4.2 Performance Objectives

ASCE 41-13 Life safety in the BSE-1E event (20%/50yr earthquake). This results
in a short period spectral acceleration of about 85% of Sds or
0.57Sms ([2/3]*0.85 = 0.57) for San Francisco3. Sds and Sms per ASCE
7-10 definitions.
IEBC A4 Prescriptive retrofit based on 75% of current code forces for new
construction. This results in a short period spectral acceleration of
0.5*Sms ([2/3]*0.75 = 0.5).
FEMA P807 30% probability of exceedance at 0.5Sms. Probability of exceedance
refers to the chance the building story drift will exceed a drift limit
that might suggest collapse.
Table 4.2 – Ordinance 66-13 Guideline Performance Objectives

The performance objectives shown above are based on Ordinance 66-13. It is important to
recognize that each retrofit has different objectives, and thus they result in different retrofits
that are not equivalent in terms of seismic safety. The engineer should inform their clients of
this information to select a guideline to best fit their client’s objective.

3
Pekelnicky R., and Poland C, ASCE 41-13: Seismic Evaluation and Retrofit of Existing Buildings, SEAOC 2012
Convention Proceedings

6
Note that ASCE 41-06 is also allowed by Ordinance 66-13, but is not one of the guidelines used
in this project.

4.3 Material Strengths

ASCE 41-13 was developed to cover a wide range of materials and building types. It contains
acceptance criteria and material strengths for all parts of the load path including diaphragms,
connections, lateral system elements, and foundations.

ASCE 41 states that the strength of dissimilar materials in wall assemblies shall not be combined
unless test data is available [ASCE 41-13, 12.4.1]. However, the commentary for the same
section refers to FEMA P807 for further information on the effects of combining dissimilar
materials. For this study, the commentary is interpreted to allow combinations of dissimilar
materials using the same procedures as FEMA P807.

IEBC A4-12 bases material strengths on code values for new construction. New retrofit
elements are designed and detailed using current code provisions for new construction. Unlike
the other guidelines, IEBC A4 does not permit the use of gypsum or plaster products to resist
lateral loads on the ground floor [IEBC A4-12, A403.9.1]. This is an important aspect for the case
study buildings since their lateral force resisting systems consists mostly of plaster-on-wood-
lath partition walls.

FEMA P807 allows use of and provides backbone curves for both wood structural panels and
gypsum/plaster walls. The backbone data is provided up to 5% drift (after this point all
materials are assumed to have no strength). P807 accounts for and encourages existing
materials to be used and combined with new retrofit elements. Guidelines for creating
composite load-drift curves are provided in P807 section 4.5.1.

FEMA P807 does not provide strength or stiffness properties for diaphragms, connections, or
foundations. The guideline recommends designing these elements to develop the strength of
the wall or moment frame used in the evaluation/retrofit analysis (FEMA P807, section 6.5.1).
For this study, the acceptance criteria for these elements come from ASCE 41-13 or the
International Building Code (IBC) depending on whether existing or new elements are being
utilized. See tables 4.3 and 4.3A for a summary of material strength assumptions used by each
of the guidelines.

7
Material tables provided for lateral system elements, diaphragms,
ASCE 41-13 foundations, and connections. Dissimilar materials were combined
using FEMA P807 rules.
Material strengths taken as those for new construction. Gypsum and
IEBC A4
plaster products cannot be used to resist lateral loads in the story.
Material tables provided for wall elements. No material tables
FEMA P807
provided for diaphragms, connections, or foundations.
Table 4.3 – Material Strengths Summary

ASCE 41-131 IEBC A4 FEMA P8073


Plaster on wood lath 400 plf 0 plf 538 plf
Horizontal sheathing 80 plf 0 plf 171 plf
Stucco 350 plf 0 plf 333 plf
Gypsum wallboard 100 plf 0 plf 213 plf
Wood structural panel (WSP) 1530 plf2,4 1020 plf2 1496 plf
(10d @ 4” O.C.)
Table 4.3A – Wall Sheathing Material Strengths Used in Study5

Table 4.3A Notes:


1. Expected strengths for shear wall elements based on ASCE 41-13 Table 12-1. Per section 12.3.2.2.1 Strength
values for WSP obtained from National Design Specification for Wood Construction (NDS).
2. 1020 plf design strength for WSP obtained from Table 4.3A of NDS Special Design Provisions for Wind and
Seismic (assuming 15/32” thick Structural 1 panels with 10d@4” spacing).
3. Peak material strength values listed in table are obtained from load-drift curve data on Table 4-1 of FEMA P807.
Only peak strength values recorded above.
4. Expected strength values for deformation-controlled actions shall be permitted to be based on 1.5 times the
yield strength [1.5*1020plf = 1530plf] per section 12.3.2.2.1 of ASCE 41-13,
5. Values in Table 4.3A represent a single layer of sheathing for one side of a wall. These values are double when
both sides of the wall are sheathed.

4.4 Strength Design Checks

This study based ASCE-41-13 retrofits on Linear Static Procedures (LSPs) since this is the
approach expected to be used in design office practice for retrofit of wood buildings (rather
than non-linear or dynamic procedures). LSPs require two local strength checks. The first is a
standard demand capacity ratio (DCR) check (mkQCE > QUD) to ensure that individual elements
are not overstressed (ASCE 41-13, Section 7.5.2.2). The second strength check limits the DCR
(QUD/QCE) to 3.0 for a linear analysis where any structural irregularities are present [ASCE 41-13,
Section 7.3.1.1]. The intent of the provision is to limit the demand amplifying effects of the
structural irregularity that a linear analysis might not capture. Even if the soft story irregularity
is mitigated in the retrofit, an out-of-plane discontinuity may still exist. This structural
irregularity occurs when an element of the seismic force resisting system in one story is offset
out-of-plane relative to an element in an adjacent story. For typical SWOF buildings majority of
the interior walls of the second story do not continue to the foundation. It should be noted that

8
ASCE 41-06 contains a similar provision except the DCR limit is capped to 2.0 [ASCE 41-06,
Section 2.4.1.1]

Two options are available when the DCR limit prevents a linear analysis from being used (i.e.
QUD/QCE >3.0). The first option is to use a nonlinear analysis, where there is no DCR limit based
on the presence of a structural irregularity. This option is consistent with the original intent of
the provision. The second option is to over-retrofit the ground floor to push the DCRs below 3.0
and validate the linear analysis. The second option is utilized in this study to keep the analysis
assumptions and computational requirements similar among the different guidelines. This
option, based on budgetary restraints, will likely reflect the expected practice in a design office.

IEBC A4 retrofits based on linear static analyses require one local strength check. This check is
based on new construction code acceptance criteria (φVn>Vu; φMn>Mu) and verifies that
individual elements are not overstressed.

FEMA P807 deviates from traditional design and does not perform stress checks individual
elements. It takes a more holistic approach by utilizing the ultimate strength of all the ground
floor elements to develop a capacity. This capacity is then compared to the earthquake demand
to determine if the building is adequate. Table 4.4 summarizes the different strength checks
required by the three guidelines.

9
Base shear: [ASCE 41-13, 7.4.1.3.1]
Vb= C1C2CmSaW
C1 = inelastic displacement modification factor
C2 = cyclic stiffness degradation modification factor
Cm = effective mass factor

Local strength check: [ASCE 41-13, 7.5.2.2.1]


ASCE 41-13 (applied
mkQCE > QUD
only to the 1st story)
m factor varies:
~3-4 for plywood, gypsum, wood sheathing [ASCE 41-13, Table 12-3]
6 for steel moment frame - Flexure [ASCE 41-13, Table 9-5]

Linear elastic analysis check: [ASCE 41-13, 7.3.1.1]


QUD/QCE < 3.0

Base shear: [75% new code, IEBC A4-12, A403.3]


Vb = 0.75(SDS/[R/I])W
R = 6.5 [wood panel shear walls; ASCE 7-10, Table 12.2.1 only if the
extreme soft story irregularity is eliminated, otherwise the lowest
IEBC A4-12
value for all floors would govern]

Local strength check:


φVn > Vu; φMn > Mu
Global strength check: [FEMA P807, 5-6; AB-107, B1.2.6.1]
Sc>Sa, where Sc is the short period spectral capacity, and Sa is the
FEMA P807 spectral demand taken as 0.5Sms per ASCE 7-10. This check is
deemed satisfied with a 30% probability of exceedance on drift
limits.
Table 4.4 – Strength Design Checks Summary

10
4.5 Drift Design Checks

ASCE 41-13 retrofits do not require any checks on story drift.

IEBC A4 limits the inelastic drift of the first story to 2.5% of the story height [IEBC A4, section
A403.4]. This limit is calculated ignoring the existing plaster, gypboard, and stucco walls on the
ground floor.

FEMA P807 does not check drift explicitly, but drift limits are built into the methodology. The
performance objective is the probability of exceeding a drift limit representing onset of
strength loss. This limit ranges from 1.25% to 4% depending on the building materials. The
strength degradation ratio (Cd) determines the onset of strength loss drift limit. If Cd is equal to
0 then 1.25% will be the drift limit. If Cd is equal to 1.0 then 4% will be the strength limit. The
actual Cd for a building is determined by an interpolation between these two limiting cases
depending on upon the materials in the building.

ASCE 41-13 No explicit drift limit for linear static analysis


IEBC A4-12 2.5% maximum inelastic story drift
No explicit drift check (drift limits from 1.25% to 4% implicit to
FEMA P807 methodology). This implicit check is deemed satisfied with a 30%
probability of exceedance on drift limits (AB-107, B1.2.6.1).
Table 4.5 – Drift Design Checks Summary

4.6 Diaphragm Assumptions

Both ASCE 41-13 and IEBC A4-12 have similar checks to identify the diaphragm rigidity.
Typically, the diaphragm of the second floor for an existing SWOF building is classified as a rigid.
The soft story irregularity implies the deformations of the first story will be large with respect to
the deflections of the diaphragm.

If the diaphragm deflects more than twice the first story drift, then the diaphragm is flexible. If
the diaphragm deflects less than half the first story drift, then the diaphragm is rigid. Anywhere
in between the diaphragm is considered stiff [ASCE 41-13, section 7.2.9.1]. If a diaphragm is
rigid, then additional torsion amplification factors need to be checked [ASCE 41-13, section
7.2.3.2.2; ASCE 7-10, section 12.8.4].

FEMA P807 assumes the diaphragm is rigid and does not require the engineer to check the
rigidity of the diaphragm. The background analyses used to derive the regression equations
assumed a rigid diaphragm.

11
5. ANALYSIS AND RETROFIT ASSUMPTIONS

5.1 Analysis Assumptions

The sample buildings were assumed to be located in San Francisco on stiff soil (site class D) with
an MCE spectral acceleration of 1.5g. While the buildings are located near adjacent structures,
the effects of pounding were not included in the analyses.4 The buildings are assumed to be on
a flat site (partially embedded structures sometimes cannot be evaluated using P807 due to the
presence of concrete retaining walls.) The following table summarizes the loads assumed for
each building.

Floor and Roof Dead Load 20 psf (horizontal area)


Interior Partitions Dead Load 20 psf (horizontal area)
Exterior Wall Self Weight 20 psf (vertical area)
Live Load (not used in P-delta) 40 psf (horizontal area)
Table 5.1 – Building Load Assumptions

The calculations were performed in EXCEL spreadsheets. The analyses for ASCE 41-13 and IEBC
A4-12 retrofits assumed LSPs. The LSP was chosen for several reasons. This type of analysis
would be consistent with what a typical engineer would use given the scope of the first story
retrofit. It also simplifies comparisons between different retrofits and identifying what
controlled each retrofit. LSP made the computational effort involved of ASCE 41-13 and IEBC
A4-12 more comparable to FEMA P807. Note that other analysis types (linear dynamic,
nonlinear static, and nonlinear dynamic) are also viable options for ASCE 41-13.

The second floor diaphragm is assumed to be rigid across all of the guidelines. This is a built into
the FEMA P807 methodology and was also used for ASCE 41-13 and IEBC A4-12 retrofits. The
additional loads due to accidental (e.g. artificial 5% mass offsets) and inherent (actual) torsion
were considered in the ASCE 41-13 and IEBC A4-12 retrofit [ASCE 41-13, Section 7.2.3.2.1; ASCE
07-10, Section 12.8.4.2]. Only inherent torsion is considered in FEMA P807. Based on the
calculations, the increase in demand due to combined torsion (inherent and accidental) is on
the order of 5-7%.

P-delta effects were considered in the ASCE 41-13 and IEBC A4-12 retrofits. To avoid analysis
iterations (since P-delta lateral forces depend on story drifts), a simplified factor was used
based on the IEBC A4-12 drift limit of 2.5%. For the EXCEL calculations, the global base shear
demand was increased by 0.025W to account for P-delta effects. This assumes the first story
reaches 2.5% drift and imposes an additional lateral load equal to 0.025 times the gravity load.
Note that this is conservative where the final story drifts are less than 2.5%.

4
For further information regarding the effects of pounding between adjacent structures see Maison, McDonald,
and Schotanus, Pounding of San Francisco-Type Midblock Buildings, Earthquake Spectra, Vol. 29, No. 3, Aug. 2013.

12
5.2 Retrofit Assumptions

In order to perform the project within the time and budget constraints, only the first floor
retrofits from different guidelines were compared. Other parts of the load path were not
checked. It was assumed that the diaphragm, connections, collectors, and foundation elements
could develop the full capacity of the first floor lateral elements.

Retrofits were designed assuming wood shear walls (10d@4”) and steel special moment frames
pinned at the base. The retrofit elements are located to maintain the existing wall layout and
openings. It was also assumed that existing conditions would not restrict placement or sizing of
new elements. In actual buildings, aspects such as ceiling space, wall cavity size, space above
garage doors, and location of utility meters could influence the retrofit design. Note that the
decision to use special moment frames versus intermediate, ordinary moment frames, or
cantilever columns will dramatically impact the ASCE 41-13 and IEBC A4-12 retrofits by reducing
the ‘R’ and ‘m’ factors.

The existing wall elements were assumed to be of good quality construction and not having
environmental deterioration (e.g. rot). No ASCE 41-13 reduction factors were applied to
material strengths specified in the different guidelines (i.e. ASCE 41 knowledge factor, kappa =
1.0). Note that the knowledge factor for ASCE 41-13 varies from 0.75 to 1.0 depending on how
much data from the existing building has been collected (drawings, field investigations and
testing, etc.). See ASCE 41-13 section 6.2.4 for more information on knowledge factors.

13
6. MID-BLOCK BUILDING RESULTS

Building 1 Overview

Building 1 represents a mid-block building in San Francisco. The first floor has two retail spaces
that extend the length of the building, (Figure 6.1). The front of the building consists of doors
and large windows facing the street that create the open front that Ordinance 66-13 targets.
Each upper floor contains four apartment units for a total of eight units in the building (Figure
6.3). Fundamental periods of the building varied from 0.65 sec (unretrofitted) to 0.29 sec (when
retrofitted).

Figure 6.1 – Building 1 Street Side Elevation

14
Figure 6.2 – Building 1 First Floor Plan

Figure 6.3 – Building 1 2nd and 3rd Floor Plans

Building 1 Retrofits (Part 1)

The following retrofits were created using the Ordinance 66-13 performance objectives
outlined in Table 4.2. Each retrofit that follows shows a plan layout identifying the location of
the retrofit elements and what percent of existing walls have a single layer of wood structural
panel (WSP). This percentage is calculated assuming that each side of the wall can have a layer
of sheathing. For example a wall with sheathing along one side will only have 50% of the wall
sheathed. See Figure 6.4 for a layout of the existing walls. There are 386 ft of walls in the X-
direction and 118 ft in the Y-direction (i.e., there are 386 ft of X-direction walls, so there is 772
ft of wall that can be sheathed with a single layer of WSP [2x386’]). Note that window and door
openings shown as dashed lines below are included in the total wall length. The moment
frames are not included in the % wall sheathed calculation.

15
Figure 6.4 – Building 1 Existing Wall Layout in First Story

A retrofit satisfying FEMA P807 is shown in Figure 6.5. Note that other retrofit layouts for the Y
direction are possible. No retrofit was required in the X direction due to large number of
existing walls; hence 0% of the walls were sheathed. Note for FEMA P807, as well as ASCE 41, it
is necessary to check existing anchorage to the foundation for existing walls that are assumed
to be part of the lateral system. This could result in substantially more scope than shown
below. The Y direction required a single moment frame along the open front and 23% of the
walls sheathed with new WSP (54 ft of 236 ft). In the Y-direction the global DCR (ultimate
strength ratio) for the retrofit is 0.92.

Figure 6.5 – Building 1 FEMA P807 Retrofit in First Story

16
A retrofit satisfying IEBC A4-12 is shown in Figure 6.6. IEBC A4-12 does not permit the use of
gypsum, stucco, or plaster to resist lateral loads. The retrofit is designed relying only on new
elements. 13% of the walls required WSP sheathing in the X direction (99 ft of 772 ft) and 53%
of the total walls were sheathed in the Y direction with new WSP (124 ft of 236 ft). Most of the
walls in the Y direction are narrow and the 2.5% drift limit controlled the design of the retrofit.
The design (not ultimate) strength DCRs of the retrofitted structure are approximately 0.80 in
the X direction. This implies about 25% strength was added to limit drift.

Figure 6.6 – Building 1 IEBC A4 Retrofit

A retrofit satisfying ASCE 41-13 is shown in Figure 6.7. 4% of the walls require sheathing in the X
direction (34 ft of 772 ft) and 51% of the total walls are sheathed in the Y direction with new
WSP. The retrofit is controlled by the DCR limit for linear analyses (see section 4.4 for
explanation). The ultimate strength DCRs (including m factors) were around 0.80 in the X
direction. This implies about 25% extra ultimate strength was added to the retrofit to justify the
use of LSP.

17
Figure 6.7 – Building 1 ASCE 41-13 Retrofit in First Story

See Table 6.1 for a summary of the different retrofits. The total length of WSP is based on a
single layer of sheathing (double layered WSP walls will be counted for twice its length). Note
that the ASCE 41-13 and IEBC A4-12 retrofits were over-strengthened to meet analysis and drift
limitations, respectively.

The strength DCRs for the ASCE 41-13 and IEBC A4-12 retrofits were on the order of 0.80,
implying about 25% additional strength added to the ground floor to meet other guideline
criteria (note that ASCE 41-13 DCR uses ultimate values and IEBC A4-12 uses design values). To
see what the retrofits would look like without the additional criteria multiply the % of wall
sheathed in the Y-direction by 0.75 (the reduction would bring the strength DCRs closer to 1.0).
This results in around 40% of the walls still require sheathing. Even without these additional
criteria, the FEMA P807 retrofit is still less extensive than ASCE 41-13 and IEBC A4-12 (24%
versus 40% of wall lengths).

Y - Direction X - Direction
Guideline % Walls Total Length of MF MF % Walls Total Length of
(Y-Dir.) WSP (Y-Dir.) Beam Column (X-Dir.) WSP (X-Dir.)
FEMA P807 24% 56 ft W12x35 W12x35 0% 0 ft
IEBC A4-12 53% 124 ft W16x50 W14x61 13% 99 ft
ASCE 41-13 51% 120 ft W14x53 W12x58 4% 34 ft
Table 6.1 – Building 1 Retrofit Summary

Building 1 FEMA P807 Comparison (Part 2)

This section evaluates the different Building 1 retrofits described above using the FEMA P807
methodology. The original material strength assumptions made for the ASCE 41-13 and IEBC
18
A4-12 were changed to the ultimate values as defined in FEMA P807 to provide a consistent
comparison. The most notable difference will be that the existing nonconforming walls of
plaster/gypsum were included in the evaluation of the IEBC A4-12 retrofit.

Figure 6.8 shows the FEMA P807 push over curves for the X direction using the three different
criteria5. The push over curves were created via EXCEL spreadsheet calculations as the sum of
the individual component backbone curves. Note that the P-delta effect is not reflected in the
graphs (including the P-delta would progressively reduce the curves with increasing drift ratio).
The existing building and FEMA P807 retrofit lines coincide because there was no retrofit
required in this direction. The IEBC A4-12 retrofit produced the strongest retrofit in this
direction. This makes sense because the original IEBC A4 retrofit was checked ignoring the
existing walls and now is being evaluated using the existing materials. The light blue dashed line
shows 1.3 times the strength of the second story. This line represents the “need-not-exceed”
cap that was added to Ordinance 66-13 (P807 also has a cap in the form of an equation that
typically yields a value of 1.3) to make all three methodologies similar and prevent over
strengthening the first floor. For this direction an engineer using IEBC A4-12 to develop the
retrofit could take advantage of this need-not-exceed limit.

Figure 6.8 – FEMA P807 X direction pushover curves

Figure 6.9 shows the FEMA P807 push over curves for the Y direction of Building 1 using the
three different criteria. In this direction the existing structure is clearly identified as being
inadequate. It is useful to note the existing structure has zero strength at 2% drift. For each
retrofit this means that any strength beyond 2% drift will come from the retrofitted elements.

5
The push-over curves show limited ductility by having rapid drop-off in load at about 6 inch roof level
displacement (1.5% drift). There is evidence that the P807 material backbone curves are conservative. See
footnote 2 for discussion.

19
For Building 1 there is a significant gap between FEMA P807 and the other two retrofits. Both
ASCE 41-13 and IEBC A4-12 retrofits have more than twice the first story strength of the FEMA
P807 retrofit. It is important to remember that the ASCE 41-13 and IEBC A4-12 retrofit designs
were not controlled by strength. They both were over strengthened to meet other
requirements. However, even without the over-strengthening, the P807 retrofit has lower
strength versus those using ASCE 41-13 or IEBC A4-12.

Figure 6.9 – FEMA P807 Y direction pushover curves

20
Table 6.2 summarizes the important FEMA P807 parameters to help interpret the push over
curves above. The percent of wall sheathed values are repeated from Part 1 here for reference
purposes. Sc is the spectral capacity and is calculated from the regression equations in FEMA
P807. This value should be compared with the spectral acceleration of the site to validate if the
structure is adequate. The strength degradation ratio (Cd) is a measurement of ductility and is
included to better understand which drift limit corresponding to onset of strength loss, see
section 4.5 for more information about Cd. Lastly, V1 is the peak first story ultimate strength
using FEMA P807 material values. FEMA P807 has a cap on the first story strength to prevent
over strengthening the ground floor thereby pushing the failure to the second floor. This value
is around 1.25 to 1.3 times the strength of the second story. For Building 1 the cap is set at 312
kips in the X-direction and 226 kips in the Y-direction. The values underlined below exceed
these limits. The engineer could potentially “take advantage” of the 1.3V2 need-not-exceed
limit that is included in Ordinance 66-13. According to P807, not limiting the first story retrofit
strength means that the building safety is controlled by an upper story failure so that further
strengthening of the first story does not increase the safety of the building – the building safety
is controlled by the upper stories.

X - Direction Y - Direction
% WallsX Sc,x Cd,x V1,x % WallsY Sc,y Cd,y V1,y
Existing 0% 0.90g 0.16 272k 0% 0.21g 0.13 47k
FEMA P807 0% 0.90g 0.16 272k 24% 0.82g 0.98 100k
IEBC A4-12 13% 1.45g 0.56 354k 53% 2.03g 1.00 268k
ASCE 41-13 5% 1.14g 0.32 300k 51% 1.91g 1.00 242k
Notes: 1) Underlined text indicates where the shear strength provided exceeds the need not exceed limits of FEMA
P807 and Ordinance 66-13. This corresponds to 312 k and 226 k in the x and y direction, respectively.

Table 6.2 – FEMA P807 Evaluation Summary

21
7. CORNER BUILDING RESULTS

Building 2 Overview

Building 2 represents a typical corner building for San Francisco (Figure 7.1). The first floor
consists of two large garages and a lobby, see Figure 7.2. The top three stories contain
apartments, see Figure 7.3. The fundamental periods of the building varied from 0.55 sec
(unretrofitted) to 0.34 sec (when retrofitted).

Figure 7.1 – Building 2 Elevation

Figure 7.2 – Building 2 First Floor Plan

22
Figure 7.3 – Building 2 Typical Upper Floor Plans

Building 2 Retrofits (Part 1)

The following retrofits were created using the performance objectives outlined in Ordinance
66-13 (see section 4.1 and 4.2). Each retrofit that follows shows a plan layout identifying the
location of the retrofit elements and what percent of existing walls have a single layer of WSP.
As for Building 1, this percentage is calculated assuming that each side of the wall can have a
layer or sheathing. For example a wall with sheathing along one side will only have 50% of the
wall sheathed. See Figure 7.4 for a layout of the existing walls. There are 149 ft of walls in the X-
direction and 181 ft in the Y-direction. (i.e., there are 149 ft of X-direction walls, so there is 298
ft of walls that can be sheathed with a single layer of WSP [2x149’]). Note window and door
openings shown as dashed lines below are included in the total wall length. The moment
frames are not included in the % wall sheathed calculation. Note that a nominal moment frame
was added below a discontinuous wall along the east side of the building. The same moment
frame (W12x26 beam and column) were used for all the Building 2 retrofits.

Figure 7.4 – Building 2 Existing Wall Layout

23
The retrofit satisfying FEMA P807 is shown in Figure 7.5. The X direction required two moment
frames along the open front and 22% of the walls sheathed (81 ft of 362 ft). The Y direction
required 13% of the walls to be sheathed with new WSP (40 ft of 298 ft). The global DCR
(ultimate strength ratios) for the retrofit varied from 0.96 to 0.99.

Figure 7.5 – Building 2 FEMA P807 Retrofit

A retrofit satisfying IEBC A4-12 is shown in Figure 7.6. IEBC A4-12 does not permit the use of
gypsum or plaster materials to resist lateral loads. The retrofit is designed relying only on new
elements. 30% of the walls required sheathing in the X direction (88 ft of 298 ft) and 45% of the
total walls were sheathed with WSP in the Y direction (161 ft of 362 ft). Most of the walls in
Building 2 are significantly longer than those in Building 1. The longer walls are much stiffer
than the short ones from Building 1 and the retrofit is controlled by the strength of the walls,
not their deflection. The design strength (not ultimate) DCRs for the WSP walls in this retrofit
range from 0.87 to 1.00

24
Figure 7.6 – Building 2 IEBC A4-12 Retrofit

A retrofit satisfying ASCE 41-13 is shown in Figure 7.7. In the X direction, 51% of the walls
required sheathing (152 ft of 298 ft) and 60% of the total walls required sheathing in the Y
direction (220 ft of 362 ft). Similar to Building 1, the retrofit is controlled by the DCR limit for
linear analyses (see Section 4.4 for more information). The ultimate strength DCRs (including m
factors) were around 0.75. This implies there is about 30% extra ultimate strength was added to
the retrofit to justify the use of LSP.

Figure 7.7 – Building 2 ASCE 41-13 retrofit

25
See Table 7.1 for a summary of the different retrofits. Note that the ASCE41-13 retrofit was
over-strengthened to meet analysis requirements.

Similar to Building 1, the ultimate strength DCRs for the ASCE 41-13 retrofit were on the order
of 0.75, implying about 25% additional strength added to the first story to meet other guideline
criteria. To see what the retrofit would look like without the additional criteria multiply the % of
wall sheathed by 0.75 (the reduction would bring the strength DCRs closer to 1.0). This results
in 46% and 38% of the walls still require sheathing for the Y and X direction respectively. Even
without these additional criteria, the FEMA P807 retrofit is still less extensive than the ASCE 41-
13 retrofit.

Y – Direction X - Direction
Guideline % Walls Total Length of % Walls Total Length of MF MF
(Y-Dir.) WSP (Y-Dir.) (X-Dir.) WSP (X-Dir.) Beam Column
FEMA P807 22% 81 ft 13% 40 ft W12x30 W12x30
IEBC A4-12 45% 161 ft 30% 88 ft W16x50 W14x68
ASCE41-13 61% 220 ft 51% 152 ft W16x50 W14x61
Table 7.1 – Building 2 Retrofit Summary

Building 2 FEMA P807 Comparison (Part 2)

This section evaluates the different Building 2 retrofits described above using the FEMA P807
methodology. The original material strength assumptions made for the ASCE 41-13 and IEBC
A4-12 will be changed to the ultimate strength values as defined in FEMA P807. The most
notable difference will be that the existing walls (having nonconforming plaster and gypsum
materials) will be included in the evaluation of the IEBC A4-12 retrofit.

Figure 7.8 shows the FEMA P807 push over curves for the X direction of Building 2. The push
over curves were created via EXCEL spreadsheet calculation as the sum of the individual
component backbone curves. Note that the P-delta effect is not reflected in the graphs
(including P-delta would progressively reduce the curves with increasing drift ratio). The ASCE
41-13 retrofit produced the strongest retrofit in this direction. The original IEBC A4-12 retrofit
was checked ignoring the existing walls and now is being evaluated using the existing materials.
The light blue dashed line shows 1.3 times the strength of the second story. This line represents
the “need-not-exceed” cap that was added to the ordinance to prevent over strengthening the
first floor. For this direction an engineer using ASCE 41-13 to develop the retrofit could take
advantage of this need-not-exceed limit. However, note that limiting the first story retrofit
strength per P807 and Ordinance 66-13 means that the building safety is controlled by an upper
story failure so that further strengthening of the first story does not increase the safety of the
building – the building safety is controlled by the upper stories.

26
Figure 7.8 – FEMA P807 X direction pushover curves

Figure 7.9 shows the FEMA P807 push over curves for the Y direction of Building 2. In this
direction the existing structure is clearly identified as being inadequate. It is useful to note the
existing structure has zero strength at 2% drift. For each retrofit this means that any strength
beyond 2% drift will come from entirely the retrofitted elements.

Figure 7.9 – FEMA P807 Y direction pushover curves

Table 7.2 summarizes the important FEMA P807 parameters to help interpret the push over
curves above. The percent of wall sheathed values are repeated from Part 1 here for reference
purposes. The spectral capacity, Sc, is calculated from the regression equations in FEMA P807.
This value should be compared with the spectral acceleration specified by the Ordinance to

27
validate if the structure is adequate. The strength degradation ratio (Cd) is a measurement of
ductility and is included to better understand which drift limit corresponding to onset of
strength loss, see Section 4.5 for more information about Cd. Lastly, V1 is the peak first story
ultimate strength FEMA P807 material values. FEMA P807 has a built in cap on the first story
strength to prevent over strengthening the ground floor and pushing the failure to the second
floor. This value is around 1.25 to 1.3 times the strength of the second story. For Building 2 to
cap is set at 338 kips in the X-direction and 311 kips in the Y-direction. The values highlighted in
red below exceed these limits and could potentially take advantage of the 1.3V2 need-not-
exceed limit that is included in Ordinance 66-13.

X - Direction Y - Direction
% WallsX Sc,x Cd,x V1,x % WallsY Sc,y Cd,y V1,y
Existing 0% 0.23g 0.00 93k 0% 0.30g 0.00 127k
P807 15% 0.79g 0.94 160k 22% 0.77g 0.77 206k
IEBC A4 30% 1.28g 0.98 288k 45% 1.30g 0.94 306k
ASCE 41 60% 1.83g 1.00 419k 61% 1.68g 0.98 376k
Notes: 1) Underline text indicates where the shear strength provided exceeds the need not exceed limits of FEMA
P807. This corresponds to 338 k and 311 k in the x and y direction, respectively.

Table 7.2 – FEMA P807 Evaluation Summary

28
8. Incremental Dynamic Analyses

Incremental dynamic analysis (IDA) is a parametric study used to better understand how a
particular building performs under dynamic loading. An IDA is typically defined using two
properties; intensity measure and damage measure. The intensity measure is the variable that
will be scaled for each analysis. For this project the intensity measure is the short period
spectral acceleration. The damage measure is a variable that can be identified in the analysis
results. This measure varies depending on the goal of the particular analysis and examples
include base shear, node rotations, and peak inter-story drifts. For this project inter-story drift
was chosen to better understand the difference between onset of strength loss limits assumed
by FEMA P807 and collapse as predicted by the analytical model.

The goal of the IDAs is to develop a collapse fragility curve for a particular building. This curve
quantifies the probability of exceeding the damage measure (collapse) for different intensity
levels (short period acceleration). Probability of collapse is approximated as the number of
ground motions that cause the structural model to collapse. For example, if 3 of 22 ground
motions result in collapse at a particular spectral acceleration a 14% probability of collapse can
be inferred. Collapse fragility curves will be used to better understand the different retrofits
produced by each of the three guidelines. This will provide a way to measure how each retrofit
improved building performance. The IDAs will also be used to identify how close the onset of
strength loss drift limit from FEMA P807 is to collapse.

IDA Assumptions

The building retrofits were modeled and analyzed using SAPwood6. SAPwood is a structural
analysis program developed as part of the NEESWood program to better understand the
seismic performance of wood frame structures. The retrofits were analyzed using a bi-
directional model that assumes 3 degrees of freedom and a rigid diaphragm per level (two
translational and one rotational). 22 pairs of “far-field” ground motions from ATC 63 were
chosen for this project (44 total records). These records were chosen because FEMA P807 was
developed using the same ground motions.

There are two different ways to scale ground motions for IDAs. The first is to scale the
individual ground motions until the average response spectrum matches the target spectrum
(FEMA P807 used this approach in its development). This procedure results in an average
response spectrum that matches the target spectrum, but does not guarantee the same
spectral acceleration at a particular period for each ground motion record. The second way is to
scale the individual ground motions to a specific spectral acceleration at the period of the
undamaged structure. This procedure will ensure that all the ground motions will be scaled to a
single spectral acceleration value, but the average of the ground records will not match a code
response spectrum. For this project the second procedure was primarily used because
SAPwood is set up to scale the individual ground motions in this way. It probably does not

6
John van de Lindt; Shiling Pei (2010), "SAPWood," https://nees.org/resources/sapwood.

29
matter much which approach is used since relative comparisons are made across the different
retrofit designs. Four spring models are available in SAPwood: linear spring model, bilinear
spring model, SAWS-type 10-parameter hysteretic model, and a 16-parameter evolutionary
parameter hysteretic model. See Table 8.1 for a summary of which spring models were used for
each element.

Existing materials 10-parameter hysteretic model


Plywood shear walls 16-parameter hysteretic model
Steel moment frames Bilinear model
P-delta column Bilinear model
Table 8.1 – SAPwood element model summary

The backbone curve parameters in the SAPwood model were adjusted to match curves
provided in FEMA P807 (but had more ductility assigned, see Appendix A). The curves have the
same strength peak strength as the FEMA P807 curves. The one modification made was to
provide additional ductility to the curves. Instead of having zero strength at 2% (non-ductile
materials) or 5% (ductile materials) drift, the curves were extended to be more realistic per the
judgment of the authors. However, they still may be conservative, see footnote 2 for more
discussion on this aspect. See Appendix A for the backbone curves used in the SAPwood
analysis. P-delta affects were accounted for by using an elastic spring with negative stiffness in
each story. The stiffness was calculated by taking the weight of the floors above and dividing it
by the story height. Collapse is defined as a lateral instability occurring in any of the stories. This
was signaled by a very large story drift in either building principle direction or failure to
converge in an analysis run.

IDA Results

ASCE 7-10 defines the performance of a code building as having a 10% chance of collapse for an
MCE event (Sa = 1.5g). In the past, existing buildings were often retrofitted using 75% of code
level forces. Currently there is no codified probabilistic performance objective for retrofits. For
the purposes of this project a 75% code fragility curve was developed by targeting a 10%
chance of collapse at 75% of MCE (assumed here as having Sa = 1.125g) event. See Figure 8.1 for
code collapse curves. A beta value of 0.4 was used to develop to curves in Figure 8.1. This value
was comparable to the beta values observed in the SAPwood results that considered only the
earthquake record-to-record uncertainty (as opposed to a beta reflecting the total collapse
uncertainty including aspects such as design requirements and modeling uncertainties). The
following curves were developed based on material strengths as defined in FEMA P807. Using
other material property assumptions could dramatically impact the results.

30
Probability of Collapse Curves
1
0.9
0.8
Probability of Collapse

0.7
0.6
0.5
0.4
0.3
0.2 75% Code at Sms=1.5

0.1 Code at Sms=1.5

0
0 0.5 1 1.5 2 2.5 3 3.5 4
Short Period Spectral Acceleration
Figure 8.1 – Building Code Collapse Fragility Curves

The following results are based on the computer analyses results from SAPwood. The code
fragility curves from Figure 8.1 are repeated in Figure 8.2 for reference. The four new curves
shown on Figure 8.2 are the collapse fragility curves for each of the four models (Existing, FEMA
P807, ASCE 41-13, and IEBC A4-12). The curves were computed as follows. At each short period
spectral value, 22 earthquake analyses were performed (using both X and Y-direction
earthquake components), and the number of runs having collapsed was used to compute the
collapse probability. A fragility curve was then fitted to the data across the various spectral
values. Based on these curves there is a dramatic improvement in the seismic performance of
Building 1, as seen by how far the retrofit curves lie to the right side of the existing building
curve. For example, at Sa = 1g the probability of collapse was reduced from 85% to 35% (FEMA
P807) or 15% (ASCE 41-13 and IEBC A4-12). While the performance is improved from the
existing condition, they retrofits fall short of the 75% code line.

31
Building 1, Collapse Fragility Curves
1.0
0.9
0.8
Probability of Collapse

0.7
0.6
0.5
ASCE 41-13
0.4
Existing
0.3 FEMA P807
0.2 IEBC A4-12
75% Code at Sms=1.5
0.1
Code at Sms=1.5
0.0
0 0.5 1 1.5 2 2.5 3 3.5 4
Short Period Spectral Acceleration
Figure 8.2 – Building 1 Collapse Fragility Curves

The curves shown on Figure 8.2 identify the probability of collapse, but do not distinguish which
direction or floor caused the structure to collapse. Tables 8.2 and 8.2a identifies the collapse
direction and floor for each of the earthquakes for the retrofitted models (each earthquake is
scaled until it produced collapse). The existing building collapses in the Y-direction of the first
floor for all ground motions (consistent with the SWOF deficiency) and is not included in the
table below. For Building 1, all of the FEMA P807 models failed at the first floor. The ASCE 41-13
and IEBC A4-12 models had more than half of their failures occur in the second floor. These
results suggest the first floor of ASCE 41-13 and IEBC A4-12 retrofits did not reach their full
strength before the second floor failed. Note that the ASCE 41-13 and IEBC A4-12 retrofits do
not take advantage of the Ordinance 66-13 provision that the first story retrofit strength need
not exceed 1.3 times the strength of the second story.

32
Earthquake FEMA P807 ASCE 41-13 IEBC A4-12
Retrofit Retrofit Retrofit
st nd nd
1 1 Floor (Y) 2 Floor (Y) 2 Floor (Y)
st st
2 1 Floor (X) 1 Floor (X) 1st Floor (X)
3 1st Floor (Y) 1st Floor (Y) 2nd Floor (Y)
4 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
5 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
st nd
6 1 Floor (Y) 2 Floor (Y) 2nd Floor (Y)
7 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
8 1st Floor (X) 2nd Floor (Y) 2nd Floor (Y)
9 1st Floor (Y) 1st Floor (X) 2nd Floor (Y)
10 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
st st
11 1 Floor (X) 1 Floor (X) 1st Floor (X)
12 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
13 1st Floor (X) 2nd Floor (Y) 2nd Floor (Y)
14 1st Floor (Y) 1st Floor (Y) 1st Floor (Y)
15 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
st nd
16 1 Floor (Y) 2 Floor (Y) 2nd Floor (Y)
17 1st Floor (X) 2nd Floor (Y) 1st Floor (X)
18 1st Floor (X) 1st Floor (X) 1st Floor (X)
19 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
20 1st Floor (Y) 1st Floor (Y) 1st Floor (Y)
st st
21 1 Floor (X) 1 Floor (X) 2nd Floor (Y)
22 1st Floor (Y) 1st Floor (Y) 1st Floor (Y)
Table 8.2 – Building 1 Collapse Locations

Failure FEMA P807 ASCE 41-13 IEBC A4-12


Location Retrofit Retrofit Retrofit
1st Floor (Y) 15 4 3
st
1 Floor (X) 7 5 4
nd
2 Floor (Y) 0 13 15
nd
2 Floor (X) 0 0 0
Table 8.2a – Building 1 Collapse Summary

The FEMA P807 guidelines have a provision to prevent over-strengthening the ground floor
thereby moving the failure to the second floor. Based on the previous pushover plots, the ASCE
41-13 and IEBC A4-12 retrofits exceeded this maximum first story strength, suggesting that the
second story could be at risk for excessive damage. Based on the SAPwood analysis, this
occurred for several of the ASCE 41-13 and IEBC A4-12 models. It should be noted that some of
the earthquakes did result in a first story failure for the ASCE 14-13 and IEBC A4-12 models. This
suggests that the designs are near the “tipping point” that provides just enough strength to the
first story before pushing failures to the second story.

33
To better understand the strength of the first story without a second story failure a separate set
of retrofit models were analyzed. These additional models added very stiff elements to the
second, third and fourth floor of Building 1. The addition of these elements isolates the
strength of the first stories and will result in collapse fragility curves based on the first story
strength alone (similar to how the retrofits were designed).

Building 1 (Rigid Upper Stories),


1.0
Probability of Collapse Curves
0.9
Probability of Collapse

0.8
0.7
0.6
0.5
Existing
0.4 FEMA P807
0.3 ASCE 41-13
0.2 IEBC A4-12
75% Code at Sms=1.5
0.1
Code at Sms=1.5
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Short Period Spectral Acceleration
Figure 8.3 – Building 1 Collapse Fragility Curves with Rigid Upper Stories

Figure 8.3 shows the collapse fragility curves for the models with rigid upper stories. All of the
models showed an improvement in seismic performance when the upper stories were made
rigid. Part of this increase in strength is due to the reduced effects of P-delta. The upper floors
do not drift relative to the floor below and the negative stiffness spring does not increase
demands on the first story. The other reason for the increased strength lies in the location of
the failure. The original ASCE 31-14 and IEBC A4-12 models for Building 1 had over half of the
earthquakes cause failure in the second level, not allowing the first floor to reach its full
strength. With the second story failure removed, the models showed an increase in strength.
Also note that the ASCE 41-13 and IEBC A4-12 retrofits shifted to the right of the 75% code
curve. When the first floor is taken in isolation of the upper floors it can meet the current
standard for retrofitting existing buildings (75% of current code). For example, at Sa = 1g, the
probability of collapse was reduced from 60% to 15% (FEMA P807) or 4% (ASCE 41-13 and IEBC
A4-12). The 75% code has a 6% probability of collapse.

Table 8.3 compares the retrofits in terms of their median short period spectral acceleration
capacities. The median is the spectral value (at the building’s fundamental period) of the scaled
earthquake suite that results in collapse for 50% of the analysis runs (11 out of 22 earthquake
runs). Comparisons at the median are independent of the beta uncertainty parameter. Retrofits

34
based on ASCE 41-13 and IEBC A4-12 have similar capacities about 20 to 30% greater than that
for the FEMA P807 retrofit.

Case Collapse in Any Collapse Restricted


Story Permitted1 to First Story2
Existing As-Built 0.60g 0.88g
FEMA P807 1.18g 1.69g
ASCE 41-13 1.54g 2.08g
IEBC A4-12 1.56g 2.15g
Notes:
Median spectral acceleration is the value that results with 50% of
the scaled earthquake records having collapse.
1
Analyses with computer models having the ability to collapse in
any story.
2
Analyses with the upper stories modeled as strong and rigid so
that collapse could occur only in the first story.
Table 8.3: Building 1 median short period spectral accelerations for collapse.

Similar to Figure 8.2, Figure 8.4 shows the collapse fragility curves for Building 2. All three
retrofits greatly decreased the probability of collapse. For example at Sa = 1g the probability of
collapse was reduced from 85% to 35% (ASCE 41-13) or 20% (FEMA P807 and IEBC A4-12).
These probabilities are larger than that from 75% code (6%).

Note that, unlike Building 1, Building 2 shows an inverse relationship between push over curve
strength and collapse probability. Figures 7.8 and 7.9 of this report identified the ASCE 41-13
retrofit as having the strongest retrofit as measured by a FEMA P807 pushover curve. The IEBC
A4-12 retrofit was the second strongest, followed by the FEMA P807 retrofit. This order is
reversed on the collapse fragility curves shown in Figure 8.4. The FEMA P807 retrofit has then
best performance of the three retrofits, followed by IEBC A4-12 and ASCE 41-13.

35
Building 2 Collapse Fragility Curves
1.0
0.9
0.8
Probability of Collapse

0.7
0.6
0.5
0.4 ASCE 41-13
Existing
0.3 FEMA P807
0.2 IEBC A4-12
0.1 75% Code at Sms=1.5
Code at Sms=1.5
0.0
0 0.5 1 1.5 2 2.5 3 3.5 4
Short Period Spectral Acceleration
Figure 8.4 – Building 2 Collapse Fragility Curves

The reason for this inverse relationship between the push over curve and the collapse
probability plot can be found in the location of the building failure. For Building 2, the FEMA
P807 retrofit collapse mechanism is in the first story. For the ASCE 41-13 and IEBC A4-12
retrofits the second story failed before the first story could reach its peak strength. The collapse
locations are noted in Table 8.4 and 8.4a below. The results support the FEMA P807 philosophy
that over strengthening the first floor could negatively impact the overall building performance.

36
Earthquake FEMA P807 ASCE 41-13 IEBC A4-12
Retrofit Retrofit Retrofit
st nd nd
1 1 Floor (Y) 2 Floor (X) 2 Floor (X)
st nd
2 1 Floor (X) 2 Floor (X) 2nd Floor (X)
3 1st Floor (Y) 2nd Floor (Y) 1st Floor (Y)
4 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
5 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
st nd
6 1 Floor (Y) 2 Floor (Y) 2nd Floor (Y)
7 1st Floor (X) 2nd Floor (Y) 2nd Floor (Y)
8 1st Floor (X) 2nd Floor (X) 2nd Floor (X)
9 1st Floor (Y) 2nd Floor (X) 2nd Floor (Y)
10 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
st nd
11 1 Floor (X) 2 Floor (X) 2nd Floor (X)
12 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
13 1st Floor (X) 2nd Floor (Y) 2nd Floor (Y)
14 1st Floor (Y) 2nd Floor (Y) 1st Floor (Y)
15 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
st nd
16 1 Floor (Y) 2 Floor (Y) 2nd Floor (Y)
17 1st Floor (X) 2nd Floor (X) 2nd Floor (X)
18 1st Floor (X) 2nd Floor (X) 2nd Floor (X)
19 1st Floor (Y) 2nd Floor (Y) 2nd Floor (Y)
20 1st Floor (Y) 2nd Floor (Y) 1st Floor (Y)
st nd
21 1 Floor (X) 2 Floor (X) 2nd Floor (X)
22 1st Floor (Y) 2nd Floor (Y) 2nd Floor (X)
Table 8.4 – Building 2 Collapse Locations

Failure FEMA P807 ASCE 41-13 IEBC A4-12


Location Retrofit Retrofit Retrofit
1st Floor (Y) 14 0 3
st
1 Floor (X) 8 0 0
nd
2 Floor (Y) 0 14 11
nd
2 Floor (X) 0 8 8
Table 8.4a – Building 2 Collapse Summary

Similar to Building 1, a second set of models are analyzed with rigid elements in the upper
stories. This will isolate the effects of the over strengthening that occurred in the ASCE 41-13
and IEBC A4-12 retrofits. See figure 8.4 for the collapse fragility curves generated by the second
set of models with rigid upper stories.

37
Building 2 (Rigid Upper Stories),
Collapse Fragility Curves
1.0
0.9
0.8
Probability of Collapse

0.7
0.6
0.5
0.4 Existing
FEMA P807
0.3 ASCE 41-13
0.2 IEBC A4-12
0.1 75% Code at Sms=1.5
Code at Sms=1.5
0.0
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Short Period Spectral Acceleration
Figure 8.4 – Building 2 Collapse Fragility Curves with Rigid Upper Stories

When the second floor failures are removed from the possible failure mechanisms the results
become similar to that of Building 1. The best seismic performance comes from ASCE 41-13,
followed by IEBC A4-12 and FEMA P807. This pattern is consistent with the push-over curves
noted earlier in the report (Figures 7.8 and 7.9). Interestingly, once the second floor is removed
from the equation, all three retrofits essentially meet or exceed the 75% code curve that was
developed to represent the standard practice for retrofitting existing structures.

Table 8.5 compares the retrofits in terms of their median short period spectral acceleration
capacities. When collapse is permitted in any story, FEMA P807 has the largest capacity that is
about 10 to 25% greater than those from ASCE 41-13 and IEBC A4-12. However, when collapse
is restricted to the first story, the trend is reversed with ASCE 41-13 and IEBC A4-12 having
capacities that are about 10 to 25% greater than that for FEMA P807. This reversal is due to
collapses occurring in the upper stories for the ASCE 41-13 and IEBC A4-12 retrofits.

38
Case Collapse in Any Collapse Restricted
Story Permitted1 to First Story2
Existing As-Built 0.61g 0.76g
FEMA P807 1.45g 1.83g
ASCE 41-13 1.16g 2.30g
IEBC A4-12 1.36g 2.06g
Notes:
Median spectral acceleration is the value that results with 50% of
the scaled earthquake records having collapse.
1
Analyses with computer models having the ability to collapse in
any story.
2
Analyses with the upper stories modeled as strong and rigid so
that collapse could occur only in the first story.
Table 8.5: Building 2 median short period spectral accelerations for collapse.

IDA Discussions

The fragility curves showed that the seismic performance of each retrofit varied between the
two buildings. For Building 1, the results of the collapse fragility curve are similar to the FEMA
P807 pushover curves where the IEBC A4-12 retrofit had the largest first story strength
followed by ASCE 41-13 and FEMA P807. Building 2, on the other hand, showed an inverse
relationship between the pushover curve strength and seismic performance (as measured by
the collapse fragility curves). For Building 2 the FEMA P807 retrofit had the best seismic
performance, while having the lowest strength as measured by the pushover curve. The cause
of this relationship is related to the collapse mechanism of the building.

Looking at the Building 2 ASCE 41 and IEBC A4 retrofits, the majority of the collapses occurred
in the second floor of the building. This is due to the strength and ductility of the upper stories
relative to those for the first story. Progressively increasing the strength and ductility of the first
story eventually results with the second story becoming the weak link in the building. When this
occurs, collapse in the upper story happens before the first story reaches its full retrofit
strength. This concept of over strengthening the first floor and increasing damage in the second
floor is part of the FEMA P807 methodology.

To better understand this phenomenon, a second set of models analyzed in SAPwood that
isolated the first story of each retrofit by adding rigid elements to the upper floors. This
eliminated the chance of a second story failure that was observed in the ASCE 41-13 and IEBC
A4-12 retrofits for Building 2. Once the upper story failure modes were removed, the seismic
performance of the ASCE 41-13 and IEBC A4-12 Building 2 retrofits significantly improved and
surpassed the performance of the FEMA P807 retrofit.

It is not clear that having a restriction on over-strengthening the first story is an appropriate
design consideration. The value of this restriction depends on how accurate the actual

39
capacities (strength and ductility) of the first and second stories can be calculated. Currently,
there is no industry consensus on the backbone curves for many of the materials found in
wood-frame buildings, and this is especially true for the older non-conforming material types
(e.g., lath-and-plaster partitions) that dominate the upper stories in the case study buildings.
ASCE 41-13, SAPwood and P807 all prescribe backbone curves that can differ significantly. It is
relevant to note that FEMA P807 admits that their backbone curves for their low-displacement
capacity materials (e.g., lath-and-plaster partitions) are difficult to imagine as reflecting reality,
and that more testing is needed (P-807 Section E.2.4). Should the upper story strength be
underestimated thereby placing an artificial limit on the first story retrofit strength, then the
overall seismic safety of the building is compromised (versus a retrofit not having an over-
strengthening restriction).

To illustrate the above conundrum, consider the median spectral accelerations for Building 2
(Table 8.6). A first story “over-strengthening restriction” might limit the upgrade to the values
in column (a) of Table 8.6 since the second story is perceived to be the weak link. However, if
the actual upper story strength was underestimated, then it is possible the first story could be
retrofitted so that the values in column (b) apply. The over-strengthening restriction could
result in a retrofitted building having about one-half the capacity when comparing columns (a)
and (b). The trade-off involves the possible savings in retrofit cost offered by having an over-
strengthening restriction versus the possible increased collapse risk by limiting the first story
upgrade.

Case (a) Collapse in Any (b) Collapse Restricted (a) divided by (b)
Story Permitted to First Story
ASCE 41-13 1.16g 2.30g 0.50
IEBC A4-12 1.36g 2.06g 0.66
Table 8.6: Building 2 median short period spectral accelerations for collapse (from Table 8.5).

It is the authors’ experience that there are few instances of upper story failures occurring in
actual earthquakes, and this is especially true for wood-frame buildings. Prediction of upper
story collapse is highly dependent on the modeling assumptions and material strength
properties. There is not a clear consensus on which material strength curves are “correct” and
properties vary between different guidelines. Note that the material strengths used in the
analysis are based on the FEMA P807 material properties (but has more ductility assigned, see
Appendix A).

Overall, the fragility curves for the various retrofits fell short of 75% of code level. Based on the
material strengths from FEMA P807 with modified ductility and the buildings chosen for this
project it appears that 75% code cannot be achieved by a first story only retrofit. When more
retrofit elements are added to the first story for Building 2 (as illustrated by going from a P807
retrofit to the ASCE 41-13 retrofit), collapse risk is not reduced. The second floor is driving the
collapse of the building. It should be noted that the collapse risk for both buildings were
dramatically reduced, even if they fell short of the 75% of code retrofit standard for existing
buildings.

40
9. CONCLUSION

San Francisco’s mandatory retrofit ordinance allows use of different approaches for retrofit
design that includes ASCE 41-13, IEBC A4-12, and FEMA P807. It should be noted that other
performance objectives do exist that go beyond those specified in the ordinance.

Based on the assumptions made in this project, ASCE 41-13 required the most extensive
retrofit, followed by IEBC A4-12 and FEMA P807. IEBC A4-12 and ASCE 41-13 have additional
provisions related to building drift and analysis limitations that need to be satisfied and these
can result with additional strengthening in the first floor. However, even without these
additional criteria, the retrofits satisfying ASCE 41-13 and IEBC A4-12 guidelines were still more
extensive than those based on FEMA P807.

Results from the SAPwood incremental dynamic analysis (IDA) for the collapse performance of
the two buildings were mixed. Building 1 showed that the ASCE 41-13 retrofit recorded the
largest first story push over strength and had the best seismic performance. Building 2 showed
that the ASCE 41-13 retrofit recorded the largest first story push over curve strength, but had
the least favorable IDA performance of the three retrofits. This resulted from the second story
of Building 2 collapsing before the first story can reach its peak retrofit strength. Once the
second floor was removed as a possible failure mechanism, the ASCE 41-13 retrofit for Building
2 outperformed the other two retrofits (IEBC A4-12 and FEMA P807) in IDA. More thought
should be given to the appropriateness of the FEMA P807 concept that limits the first story
retrofit depending on the calculated capacity of the upper stories since this has great
uncertainty due to industry current lack of knowledge. Further studies should be performed to
validate the FEMA P807 philosophy that over strengthening the first floor can decrease seismic
performance and if certain building layouts/sizes are more susceptible to this phenomenon.

Based on FEMA P807 material assumptions, the SAPwood results of the two sample buildings
suggest a first story retrofit will likely not be able to reach the 75% of current code standard for
existing building retrofits. When additional strength was added to the ASCE 41-13 and IEBC A4-
12 retrofits for Building 2 (without strengthening the upper floors), a second story collapse
mechanism occurred and reduced the overall seismic performance of the building. While falling
short of the 75% current code fragility curve, all of the retrofits greatly reduced the collapse risk
of the buildings. Note that these results are based on the material strength curves provided by
FEMA P807. Other guidelines (ASCE 41-13 and IEBC A4-12) have different assumptions for
material strength, as noted in section 4, and could produce different results.

It is challenging to compare the performance of each of the retrofits, because it is dependent


on the analysis assumptions. The building code allows the use of four different analyses (linear
static, linear dynamic, non-linear static, and non-linear dynamic). Each of these options will
produce different designs that all meet the performance objective of the code. Likewise the
three guidelines used in this study produced different retrofits based on different assumptions.
ASCE 41-13 is intended to cover all building types, ages, and materials. It is a comprehensive
tool to be used for first floor retrofits of wood frame buildings and it is not surprising that it

41
appears to be the most conservative of the three. FEMA P807, on the other hand, is a very
specific tool that was developed to target a small subset of the housing stock. It is not surprising
that these documents produced different results.

It is important to recognize that the retrofits and associated conclusions made in this study are
highly dependent on the analysis and design assumptions. Regarding analysis modeling, there is
currently no consensus on the load-drift (backbone) curves for many of the materials found in
wood-frame buildings. P807 and ASCE 41-13 prescribe backbone curves that differ significantly,
and a recent review indicates all of these might be conservative (see footnote 2 on page 5 for
discussion). Regarding design aspects, if the IEBC A4-12 Building 1 retrofit used WSP with
10d@2” O.C., instead of 10d@4” O.C., then drift might not have controlled the design. Also,
fixing the base of the moment frame could sufficiently stiffen the ground floor and require a
flexible diaphragm assumption. Using a special versus an ordinary moment frame will also
impact the design loads depending on which guideline is used. Varying the retrofit elements,
analysis assumptions, and location of retrofit elements could change the results presented in
this study. Note that other parts of the building load path not checked in this study
(diaphragms, connections, hold downs, and foundations) could significantly impact the results
of the study.

This study is intended to help provide a basis by which the engineer can judge which guideline
would best suit their client’s goals. The authors trust this study can be used to better
understand the different guidelines and select the one that best suits the client’s needs.

42
Appendix A – SAPwood Material Backbone Curves

The following figures are provided to illustrate the material curve assumptions made for the
SAPwood IDA analyses. The curves used for the SAPwood analyses are based on the FEMA P807
curves. FEMA P807’s assumption of zero residual strength at 1.25% and 5% drift for non-ductile
and ductile materials respectively is very conservative. Additional ductility was added to each
material based on the judgment of the authors (however, these still may be conservative, see
footnote 2 on page 5 for discussion).

(1) 10d@4" Plywood Wall


30000

20000

10000
Strength (lbs)

Hysteresis Loop
0
SAPwood Curve
-10 -5 0 5 10
P807 curve
-10000

-20000

-30000
% Drift

Figure A.1 – Single layer of 10d@4” O.C.

43
(2) 10d@4" Plywood Wall
25000
20000
15000
10000
Strength (lbs)

5000
Hysteresis Loop
0
SAPwood Curve
-10 -5 0 5 10
-5000
P807 curve
-10000
-15000
-20000
-25000
% Drift

Figure A.2 – Double layer of 10d@4” O.C.

(1) wood lath (1) horz. sheathing


10000
8000
6000
4000
Strength (lbs)

2000
Sample Hysteresis Loop
0
SAPwood Curve
-10 -5 0 5 10
-2000
P807 curve
-4000
-6000
-8000
-10000
% Drift

Figure A.3 – One Layer of Wood Lathe on Plaster, One layer of Horizontal Sheathing

44
(2) wood lath
80000

60000

40000

20000
Strength (lbs)

Sample Hysteresis Loop


0
SAPwood Curve
-10 -5 0 5 10
-20000 P807 curve

-40000

-60000

-80000
% Drift

Figure A.4 – Two Layers of Wood Lathe of Plaster

Moment Frame
150000

100000

50000
Strength (lbs)

0 Sample Hysteresis Loop


-10 -5 0 5 10 SAPwood Curve
-50000

-100000

-150000
% Drift

Figure A.5 – Steel Moment Frame

45
Appendix B – SAPwood Pushover Curves

The following figures show the first story pushover curves produced from the SAPwood models.
The loading pattern monotonically displaced the second floor of each building to a 7% drift. The
loading protocol was applied to each direction independently. The SAPwood curve includes P-
delta. For simplicity an average overturning factor was used for the wall input into SAPwood, as
opposed to having an individual factor for each wall. This averaging, in tandem with the added
P-delta effects, creates small discrepancies between the two curves. A single averaged
overturning factor is used across the different retrofits for each building in both directions. The
resulting discrepancy occurs across the different retrofits. For example, building 1 in the X-
direction shows the P807 curve slightly higher for all four models. The P807 pushover curves
from part 2 of the project are also included for reference.

B1 (E) - Pushover Curve (Y-Dir)


60000
50000
40000
30000
Story Shear (lbs)

20000
10000
SAP wood
0
P807 (E Bldg)
-10000 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0

-20000
-30000
-40000
-50000
Building Drift (%H)

Figure B.1 – Building One No Retrofit (Y-Direction) Pushover Curves

46
B1 (E) - Pushover Curve (X-Dir)
300000

250000

200000
Story Shear (lbs)

150000
SAP wood
100000 P807 (E Bldg)

50000

0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
-50000
Building Drift (%H)

Figure B.2 – Building One No Retrofit (X-Direction) Pushover Curves

47
B1 (P807) - Pushover Curve (Y-Dir)
120000

100000
Story Shear (lbs)

80000

60000
SAP wood
40000 P807 (P807 Retrofit)

20000

0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.3 – Building One FEMA P807 Retrofit (Y-Direction) Pushover Curves

B1 (P807) - Pushover Curve (X-Dir)


300000

250000

200000
Story Shear (lbs)

150000

100000 SAP wood


P807 (P807 Retrofit)
50000

0
0.0 2.0 4.0 6.0 8.0
-50000

-100000
Building Drift (%H)

Figure B.4 – Building One FEMA P807 Retrofit (X-Direction) Pushover Curves

48
B1 (ASCE 41) - Pushover Curve (Y-Dir)
300000

250000
Story Shear (lbs)

200000

150000
SAP wood
100000 P807 (ASCE 41 Retrofit)

50000

0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.5 – Building One ASCE 41-13 Retrofit (Y-Direction) Pushover Curves

B1 (ASCE 41) - Pushover Curve (X-Dir)


350000

300000

250000
Story Shear (lbs)

200000

150000 SAP wood


P807 (ASCE 41 Retrofit)
100000

50000

0
0.0 2.0 4.0 6.0 8.0
-50000
Building Drift (%H)

Figure B.6 – Building One ASCE 41-13 Retrofit (X-Direction) Pushover Curves

49
B1 (IEBC A4) - Pushover Curve (Y-Dir)
350000

300000

250000
Story Shear (lbs)

200000

150000 SAP wood


P807 (IEBC A4 Retrofit)
100000

50000

0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.7 – Building One IEBC A4-12 Retrofit (Y-Direction) Pushover Curves

B1 (IEBC A4) - Pushover Curve (X-Dir)


400000
350000
300000
Story Shear (lbs)

250000
200000
SAP wood
150000
P807 (IEBC A4 Retrofit)
100000
50000
0
0.0 2.0 4.0 6.0 8.0
-50000
Building Drift (%H)

Figure B.8 – Building One IEBC A4-12 Retrofit (X-Direction) Pushover Curves

50
B2 (E) - Pushover Curve (Y-Dir)
200000

150000

100000
Story Shear (lbs)

50000 SAP wood


P807 (E Bldg)
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
-50000

-100000
Building Drift (%H)

Figure B.9 – Building Two No Retrofit (Y-Direction) Pushover Curves

B2 (E) - Pushover Curve (X-Dir)


120000
100000
80000
Story Shear (lbs)

60000
40000
SAP wood
20000
P807 (E Bldg)
0
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
-20000
-40000
-60000
Building Drift (%H)

Figure B.10 – Building Two No Retrofit (X-Direction) Pushover Curves

51
B2 (P807) - Pushover Curve (Y-Dir)
300000

250000
Story Shear (lbs)

200000

150000
SAP wood

100000 P807 (P807 Retrofit)

50000

0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.11 – Building Two FEMA P807 Retrofit (Y-Direction) Pushover Curves

B2 (P807) - Pushover Curve (X-Dir)


250000

200000
Story Shear (lbs)

150000

SAP wood
100000
P807 (P807 Retrofit)

50000

0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.12 – Building Two FEMA P807 Retrofit (X-Direction) Pushover Curves

52
B2 (ASCE 41) - Pushover Curve (Y-Dir)
500000
450000
400000
350000
Story Shear (lbs)

300000
250000
SAP wood
200000
P807 (ASCE 41 Retrofit)
150000
100000
50000
0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.13 – Building Two ASCE 41-13 Retrofit (Y-Direction) Pushover Curves

B2 (ASCE 41) - Pushover Curve (X-Dir)


500000
450000
400000
350000
Story Shear (lbs)

300000
250000
SAP wood
200000
P807 (ASCE 41 Retrofit)
150000
100000
50000
0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.14 – Building Two ASCE 41-13 Retrofit (X-Direction) Pushover Curves

53
B2 (IEBC A4) - Pushover Curve (Y-Dir)
350000

300000

250000
Story Shear (lbs)

200000

150000 SAP wood


P807 (IEBC A4 Retrofit)
100000

50000

0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure B.15 – Building Two IEBC A4-12 Retrofit (Y-Direction) Pushover Curves

B2 (IEBC A4) - Pushover Curve (X-Dir)


450000
400000
350000
Story Shear (lbs)

300000
250000
200000 SAP wood
150000 P807 (IEBC A4 Retrofit)
100000
50000
0
0.0 2.0 4.0 6.0 8.0
Building Drift (%H)

Figure A.16 – Building Two IEBC A4-12 Retrofit (X-Direction) Pushover Curves

54

You might also like