You are on page 1of 14

Operation, technical Classification Page

and maintenance

VDL 6000/FASS
manual Unclassified 1 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

Operating, technical and


maintenance manual

CNSS-05-1187-E

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 2 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

TABLE OF CONTENTS
1 SCOPE......................................................................................................................... 4
1.1 Identification ........................................................................................................ 4
1.2 Contact CNS Systems......................................................................................... 6
1.3 Acronyms and Abbreviations............................................................................. 6
1.4 Applicable standards .......................................................................................... 6
2 VDL 6000/FASS DESCRIPTION ................................................................................. 7
2.1 Hardware and software configurations ............................................................. 7
3 INSTALLATION ........................................................................................................... 7
4 SETTING TO WORK.................................................................................................... 8
4.1 Initial settings ...................................................................................................... 8
4.1.1 Ground connection......................................................................................... 8
4.1.2 Input power .................................................................................................... 8
4.1.3 Antenna connections...................................................................................... 8
4.2 Configuration....................................................................................................... 8
5 OPERATION ................................................................................................................ 9
5.1 Start-up ................................................................................................................ 9
5.2 Shutdown............................................................................................................. 9
5.3 Operational modes.............................................................................................. 9
5.3.1 Off mode ........................................................................................................ 9
5.3.2 On/Standby mode .......................................................................................... 9
5.3.3 Maintenance mode....................................................................................... 10
5.3.4 Service modes ............................................................................................. 10
5.4 Sentences .......................................................................................................... 10
5.5 Monitoring and control of the VDL 6000/FASS ............................................... 12
6 MAINTENANCE ......................................................................................................... 13
6.1 Periodic planned maintenance......................................................................... 13
6.2 Recommended spare parts .............................................................................. 13
6.3 Electrical fuses .................................................................................................. 13
6.3.1 AC fuse ........................................................................................................ 13

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 3 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

6.3.2 DC fuses ...................................................................................................... 14

TABLE OF FIGURES
Figure 1, VDL 6000/FASS in Basic configuration................................................................................................................................... 4
Figure 2, VDL 6000/FASS in Advanced Configuration with redundant FAS ................................................................................... 5

LIST OF TABLES
Table 5-1, Modes of the VDL 6000/FASS................................................................................................................................................ 9
Table 5-2, VDL 6000/FASS input / output sentences .........................................................................................................................10
Table 6-1, Periodic planned maintenance – VDL 6000/FASS ............................................................................................................13

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 4 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

1 SCOPE

1.1 Identification
This Installation manual is intended for the VDL 6000/FASS (Fixed AIS Station System) and is applicable for both Basic
and Advanced configurations.

Figure 1, VDL 6000/FASS in Basic configuration

VDL 6000/FASS in Basic configuration are available with different hardware and software features. The trade names of the
different hardware configurations of the VDL 6000/FASS Basic are VDL 6500-1X, there X specify the different hardware
configuration. The trade names of the different software features of the VDL 6000/FASS Basic are described by the
software part number SW 6500-2X, where X specifies the different software features. Irrespective of hardware configuration
and software features all requirements according to IEC 62320-1 are fulfilled.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 5 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

Figure 2, VDL 6000/FASS in Advanced Configuration with redundant FAS

VDL 6000/FASS in Advanced configuration are available with different hardware and software features. The trade names
of the different hardware configurations of the VDL 6000/FASS Advanced are VDL 6500-2X, there X specify the different
hardware configuration. The trade names of the different software features of the VDL 6000/FASS Advanced are described
by the software part number SW 6500-2X, there X specify the different software features. Irrespective of hardware
configuration and software features all requirements according to IEC 62320-1 are fulfilled.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 6 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

1.2 Contact CNS Systems


Address: C.N.S. Systems AB
St. Larsgatan 32 B
SE-582 24 Linköping
SWEDEN

Telephone: +46 13 35 22 90
FAX: +46 13 35 22 99
Email: info@cns.se
Web: www.cns.se

1.3 Acronyms and Abbreviations

Acronym Description

FAS Fixed AIS Station, i.e. the radio transceiver in the VDL
6000/FASS

FASS Fixed AIS Station System

LAN Local Area Network

MCT Monitor and Control Tool

PI Presentation interface

1.4 Applicable standards


IEC 62320-1:2007 Maritime Navigation and Radio Communication Equipment and Systems – Automatic
Identification System Part 1
AIS Base Stations – Minimum operational and performance requirements, methods of
testing and required test result.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 7 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

2 VDL 6000/FASS DESCRIPTION

Warning
This is a class A* product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.

* Class A refers to the European Standard EN55022 (Information Technology Equipment – Radio disturbance
characteristics, Limits and methods of measurement).

2.1 Hardware and software configurations


Hardware and software configurations are described in the VDL 6000/FASS Product Specification.

3 INSTALLATION
Installation shall be performed according to the Installation manual.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 8 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

4 SETTING TO WORK
When the VDL 6000/FASS is installed in compliance with the Installation manual the following setting-to-work procedures
shall be performed.

4.1 Initial settings


Before starting the VDL 6000/FASS some initial settings need to be checked/adjusted. The following items shall be
checked/adjusted:

4.1.1 Ground connection


Check that the VDL 6000/FASS is connected to the ground plane of the building as described in the Installation manual.

Connection of the Ground Bolt is a mandatory procedure and shall be done before connecting
any other cables to the VDL 6000/FASS

4.1.2 Input power


Check that the VDL 6000/FASS is connected to the main power supply as described in the Installation manual.

4.1.3 Antenna connections


Check that the GPS antenna cable is connected to the VDL 6000/FASS as described in the Installation manual.
Check that the VHF antenna cables are connected to the VDL 6000/FASS as described in the Installation manual.
The VDL 6000/FASS Base station operates in simplex mode.

4.2 Configuration
Configuration of the VDL 6000/FASS shall be done according to the Monitor and control tool manual. For specific details
of configuration, VDL reservations, messages, etcetera please advice IEC 62320-1.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 9 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

5 OPERATION

5.1 Start-up
The VDL 6000/FASS is started in the following way:
1. Push the main power switch to the ON function.
2. Check that the FAS(s) is being powered.

5.2 Shutdown
The VDL 6000/FASS is shutdown in the following way:
1. In the advanced configuration, select shutdown in the MCT and wait for the “It is now safe to turn off the power”
dialog.
2. Push the main power switch to OFF or use the IP relay when applicable.

5.3 Operational modes


The VDL 6000/FASS includes the following modes:
Table 5-1, Modes of the VDL 6000/FASS

Mode Clarification

Off The VDL 6000/FASS is inoperable and without power.

On/Standby The VDL 6000/FASS is powered and performing initializing or closing


procedures. It is operating but services are not provided.

Normal The VDL 6000/FASS is in operational mode and all services are enabled.

Downgraded The VDL 6000/FASS is in operational mode but some or all services are
disabled.

Degraded The VDL 6000/FASS is in operational mode, but a service or a subunit is not
working properly.

Maintenance The VDL 6000/FASS is in maintenance mode, it is possible to change


configurations etc.

5.3.1 Off mode


The Off mode applies when the VDL 6000/FASS is not powered and not in operation.

5.3.2 On/Standby mode


When the VDL 6000/FASS is started-up or shutdown it is automatically transferred to On/Standby mode, which is a
transitional mode that is passed through at initializing and closing down procedures.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 10 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

5.3.3 Maintenance mode


When the VDL 6000/FASS is in maintenance mode, it is possible to perform configuration activities and update of
software.
The VDL 6000/FASS is operational but services are not provided.
Maintenance mode is announced via the Monitor and control tool.

5.3.4 Service modes


In service mode, the VDL 6000/FASS is operating and providing one or more of the implemented services.
When the VDL 6000/FASS is in service mode, the Monitoring and control subsystem will monitor the status and function
of all subsystems and provide monitoring data via the keyboard/display or by local or remote access.

5.3.4.1 Normal mode


When the VDL 6000/FASS is in normal mode, it is fully operational and provides all requested services.

5.3.4.2 Downgraded mode


When the VDL 6000/FASS is in downgraded mode, at least one of the implemented services is disabled.

5.3.4.3 Degraded mode


When the VDL 6000/FASS is in degraded mode, a failure condition has been detected in either a service and/or subsystem.

5.4 Sentences
Following sentences are supported by the VDL 6000/FASS. X indicates input to, or output from, the VDL 6000/FASS. Q
indicates that the sentence may be externally requested using th IEC 61162-1 query sentences.
Table 5-2, VDL 6000/FASS input / output sentences

Sentence Input Input Output Output Description


independent dependent independent dependent

ABK X Addressed and binary broadcast


acknowledgement

ABM X Addressed binary ad safety related


message

ACA X Q AIS regional channel assignment


message

ACM X Preparation and initiation of an


AIS Base Station addressed
channel message (VDL Message
22)

ACK X X Acknowledge alarm

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 11 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

ADS X X AIS device Status (output interval


configured by BCE and upon
status change)

AGA X Preparation and initiation of an


AIS Base Station broadcast of a
group assignment message (VDL
Message 23)

ALR X X Set alarm state

AIR X AIS interrogation request (VDL


Message 15)

ASN X Preparation and initiation of an


AIS Base Station broadcast of
assignment VDL 16 Message

BBM X Broadcast binary message

BCE X X Q Q General Base Station


configuration extended

BCF X X Q Q General Base Station


configuration

CAB X X Q Q Control AIS Base Station

DLM X Q Data Link Management slot


allocations for Base Station (VDL
Message 20 – FATDMA
resevations)

ECB X Q Configure broadcast rates for Base


Station messages with epoch
planning support

FSR X X Farme summery of AIS reception,


defined by SPO

SID X X Installation of a station’s


identification

SPO X X Q Q Select AIS device’s reception


processing and output

TFR X X Transmit feed-back report - Base


Station report on status of
requested transmission. Automatic
status response of TSA+VDM

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 12 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

TSA X X Transmit Slot Assignment – Used


to identify AIS tiome slot used to
transmit the content of a VDM
sentence

TSP X Transmit slot Prohibit

TSR X Transmit Slot Prohibit status


Report. Automatic status response
of TSP.

VDM X X X X VHF Data-link message

VDO X X VHF Data-link Own-vessel


message

VER Q Q Version information abaout


equipment. Provided in response
to ABQ.

VSI X X VDL signal Information, defined


by SPO.

5.5 Monitoring and control of the VDL 6000/FASS


Monitoring and control of the VDL 6000/FASS is described in the Monitor and control tool manual.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 13 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

6 MAINTENANCE
The occurrence of any equipment failure should be reported to CNS Systems as soon as possible.

6.1 Periodic planned maintenance


In order to assure a continued and safe operation it is recommended to perform maintenance as defined in Table 6-1.

Table 6-1, Periodic planned maintenance – VDL 6000/FASS

Maintenance object Maintenance action Maintenance Comment


interval

VDL 6000/FASS Visual inspection: Check – once


every year
• Check that no fuses are
blown.
• Remove dust from air
intake and air outtake.
• Check that all external
interface cables are
properly attached.
VDL 6000/FASS The VDL 6000/FASS includes Check – once When needed, the VDL 6000/FASS
fans two fans. Check that they are every year fans can be replaced with spare fan
operating correctly. units
Note: The fans are temperature
controlled.

6.2 Recommended spare parts


The list of spare parts recommended for local storage includes:
• VDL 6000/FAS (radio transceiver),
• Controller (if included in configuration),
• Power Supply Unit.
• Fan
All parts of the VDL 6000/FASS can be separately ordered from CNS Systems. The part number of the VDL 6000/FASS,
shall then be used for identification of the parts included in the specific configuration. The part number can be found in the
identification label located at the rear side.

6.3 Electrical fuses


6.3.1 AC fuse
The main power external interface includes one 5x20mm slow 6.3 A fuse.
When the fuse is blown, the reason for this must always be investigated before the replacement fuse is installed.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E
Operation, technical Classification Page

and maintenance
manual Unclassified 14 (14)
Date
2008-01-11
Document No. Issue
CNSS-05-1187 E

6.3.2 DC fuses

6.3.2.1 Automatic fuses (Applicable for part number VDL 6070-NN-10)


All VDL 6000/FASS with part number VDL 6070-NN-10 includes a number of (depending on configuration) automatic
fuses located on the rear side.
When a fuse is blown, the reason for this must always be investigated before the fuse is restored (this is done by pushing the
knob of the fuse back into un-blown position).

6.3.2.2 Glass tube fuses (Applicable for all other part numbers)
All VDL 6000/FASS with part number VDL 6070-NN-11, -12, -13… and VDL 6500-NN includes a number of (depending
on configuration) glass tube fuses located on the rear side.
When a fuse is blown, the reason for this must always be investigated before the fuse is replaced.
All DC fuses are 5x20mm 5A fast glass tube fuses. One spare fuse is mounted on the rear side.

_______________________________________________________________________________________________________________________________________________
This document and attachments shall remain our property. They may not without our written consent, either in their original state or with any changes, be copied or reproduced,
disclosed to or delivered to anyone unauthorized nor used for other purposes than what has been confirmed by C.N.S. Systems AB in writing.

BL0004E