OWNER’S MANUAL

Downloaded from www.Manualslib.com manuals search engine


This manual applies to the
following models

Contents

ENGLISH
51AKB 010 Page
Control panel .................................................... 1
51AKC 013 Accessories supplied ....................................... 1
General information ......................................... 2
Correct use .................................................... 2/3
Preparing to use ............................................... 4
Cooling with dehumidification ......................... 5
Dehumidification ............................................... 6
Fan only ............................................................ 7
Cleaning ............................................................ 7
Read this instruction manual In case of .......................................................... 8
thoroughly before using
the air conditioner.

Control panel

9 10 11 12 9

1
8 TURBO
2
3
7 SILENT
4
5

1. OFF position 7. Low fan speed


2. TURBO cooling 8. High fan speed
3. Mode selector 9. Alarm indicator light
4. SILENT cooling 10. Fan speed indicator lights
5. Dehumidification 11. Cooling indicator light
6. Thermostat 12. Dehumidification indicator light

Accessories supplied

1
2 1. Mounting brackets for the outdoor unit
3 2. Screws, nuts and washers for fixing
the mounting brackets
3. Fastening strap with suction cup
4 4. Strap with spring-clips

GB - 1
Downloaded from www.Manualslib.com manuals search engine
General information

Unit installation table “Operating limits” of the unit owner’s Choosing the installation site
manual, will immediately invalidate the unit
Read this instruction manual thoroughly warranty. • Choose an area free from obstructions which
before installing the unit and keep it for may cause irregular air distribution and/or return.
• It is recommended to install a circuit breaker
further consultation even after installation. • Choose a position that allows for the clearances
or a 16 A safety fuse upstream of the supply required (see “Correct use” section).
• This unit complies with the following outlet.
directives: • Look for a position in the room which
- low-voltage 73/23/CEE; Unit operation assures the best possible air distribution.
- electromagnetic compatibility 89/336/CEE; Positions to avoid:
• In order to avoid electric shock, fire or injury, • Exposed to direct sun.
- PED Pressure Equipment 97/23/CE; stop the unit in case of abnormal events
- energy labelling 2002/31/CE. • Too close to heat sources.
(such as smell of burning) and call Carrier • On humid walls or positions with water
• For safety reasons, installers are required to Service for further instructions. hazard, e.g. laundry premises.
read the general information carefully. • Do not place containers filled with liquids or • Exposure to oil vapours (e.g. kitchens,
• Follow all the instructions below to ensure other objects onto the unit. workshops).
safety. • Where curtains or furniture may obstruct free
• Inspect the unit for damage due to improper Maintenance air circulation.
transport. In case of damage, file an WARNING:
immediate claim with the shipping company. Unit disposal:
disconnect the mains power supply prior
• Do not install or use damaged equipment. to any maintenance operations or prior to • At the end of its life, the air conditioner must
• To prevent fire, explosion or injury, do not handling any internal parts of the unit. be delivered to a special collection centre or
operate the unit near dangerous substances to the dealer for the refrigerant disposal.
or close to naked light equipment. • A routine maintenance should be carried out • All of the manufacturing and packaging
• Ensure that national safety code on the unit to check the correct operation of materials used for this unit are compatible
requirements have been followed for the the electric connections and protection with the environment and can be recycled.
main supply circuit. Follow all current devices. • Dispose of the packaging material in
national safety code requirements for the • A damaged power cord of units equipped accordance with local requirements.
installation. with quick-connection couplings of the Y-type
• Make sure a connected ground wire is in must be replaced by the manufacturer or its SPLIT unit performance:
place. after-sales service. The unit is designed to operate within the following
• Check that voltage and frequency of the • Maintenance operations must be carried out temperature limits according to the standards:
mains power supply are those required for by specially trained personnel. Cooling: (EN14511:2004)
the unit to be installed; the available power • Do not attempt to repair, move, modify the Indoor temperature
must be adequate to operate any other unit on your own. To avoid electric shock or Max. 32°C d.b.* / 23°C w.b.*
appliances connected to the same line. fire make sure these operations are carried Min. 21°C d.b.* / 15°C w.b.*
• The manufacturer declines any liability from out by qualified personnel only. Outdoor temperature:
damage resulting from modifications in the • Contact the qualified service if one of the Max. 46°C - Min. 21°C
unit or errors in the electrical or hydraulic following events takes place: Dehumidification:
connections. - hot or damaged power supply cable; Max 32°C d.b.* / 24°C w.b.*
Failure to observe the installation - unusual noise during operation; Min. 18°C d.b.* / 14°C w.b.*
instructions, or use of the unit under - frequent operation of the protection devices; * d.b. - dry bulb temperature -
conditions other than those indicated in the - unusual smell (such as smell of burning). * w.b. - wet bulb temperature

Correct use

The air conditioner models The compact, light weight


51AKB010 consist of two outdoor unit is placed
units connected by a flexible outdoors.
tube of 1.8 metre length.
Models 51AKC013 sare
provided with a flexible tube
of 3.6 metre length and
quick coupling connections
that allow the units to be
disconnected up to a
maximum of six times
without impairing air
conditioning performance.
This operation must
always be carried out by
qualified and authorized The elegant portable indoor unit may be
personnel. positioned conveniently in the room to be air conditioned.

IMPORTANT The outdoor unit


At first start-up of the unit proceed may be hung on
as follows: the back of the
indoor unit with the
• take out the water tank at the rear flexible tube neatly
of the air conditioner coiled, but never
• remove the adhesive tape strip kinked, to allow air
• replace the tank correctly in its conditioner to be
position moved from room
to room. It is
If the above procedure is not followed, recommended to
the unit will not operate and indicate a move the unit
fault. holding the front
panel as illustrated.

GB - 2
Downloaded from www.Manualslib.com manuals search engine
Correct use
ENGLISH

5 MIN.

ITALIANO
Do not obstruct the sides, front and rear
Always disconnect the cable from the grille with curtains or other objects.
power socket before moving or cleaning Do not put objects on the unit.
the unit. When switching off or moving the unit to The distance between the return air grills
Never use the plug to switch the unit on or another place wait at least 5 minutes and any walls, furniture or obstructions of
off. before restarting the air conditioner. all kinds must be at least 100 mm.

60°
10°
Adjusting the air flow direction
The air conditioner has a guide vane
at the top that can be adjusted to any
angle between 10° (partially closed)
and 60° (fully open).
Depending on the angle, the air flow
direction changes as shown.
Never use the air conditioner with the
guide vane closed.
To change the room temperature turn:
the thermostat knob clockwise to lower
the temperature and counterclockwise to
raise it.

When the unit is not in use, coil the


power cord, hang it on the hook supplied
Never let the outdoor unit hang on Never move either unit by pulling on the and hung the outdoor unit on the back of
the flexible tube. flexible tube. the indoor unit.

If required, the air conditioner can be


installed with the outdoor unit hunging
from a window sill, using the supplied
accessories.

Air Quality Filter (if included)


The Air Quality Filter permits to obtain
cleaner air, purified from pollen,
bacteria, tobacco smoke etc.

GB - 3
Downloaded from www.Manualslib.com manuals search engine
Preparing to use

1 2

Outdoor section may be placed on the ground or a balcony or


Place the outdoor unit outside, ensuring that air can circulate hung from a window sill using the straps and bracket
freely around and through the unit. provided.

For window sill installation use the supplied bracket and screws.
Fix the bracket to the waindow sill as shown.

4 5 6

Secure the casing to the bracket with Making a cut-out of 35 x18 mm in the
the spring-clips at the end of the straps. The flexible tube can be trapped between lower window or door frame to
Adjust the length of the straps so that the two shutters set ajar. accomodate the flexible tube allows the
casing is level. This will help with the For this solution, use the window suction unit to be used with the window or door
discharge of the condensate water. cup supplied, as shown. closed.

GB - 4
Downloaded from www.Manualslib.com manuals search engine
Cooling with dehumidification
ENGLISH
1 2

ITALIANO
Place the flexible tube between two
shutters set ajar.
Place the outdoor unit outside, ensuring that air can circulate freely around Hold the hose end in position with the
and through the unit. fastening strap and suction cup.

3 4 5

The appliance is now ready for cooling.


The unit has two fresh air outlets,
so that the desired room temperature
Plug the unit in. Open the air flow direction guide vane. is reached quickly.

6 7 8

TURBO

SILENT

Set the thermostat to maximum


Turn the mode selector to TURBO cooling by turning the control knob The cooling mode indicator light
cooling or to SILENT cooling. clockwise. on the control panel is illuminated.

9 10 11

TURBO

SILENT

When the desired room temperature


is reached turn the thermostat control In this way the desired room To switch the unit off, turn the mode
knob counterclockwise until the cooling temperature is automatically selector counterclockwise to the
indicator light switches off. maintained. symbol .

GB - 5
Downloaded from www.Manualslib.com manuals search engine
Dehumidification

1 2

TURBO

SILENT

The dehumidification only function should be used if you want


to remove moisture from the room air without lowering the
temperature. Plug the unit in.
Place the unit in the space to be dehumidified (room, garage, Open the air flow direction guide vane.
cellar or storeroom). Turn the mode selector to the dehumidification symbol.

3 4 5

TURBO

SILENT

If the two red indicator lights


on the control panel light up,
The dehumidification indicator light this shows that the condensate water
on the control panel is illuminated. collection tank is full.
The air conditioner removes moisture from If this is the case the unit automatically To empty the tank, switch the unit off by
the air without lowering the temperature. switches off. turning the mode selector to the symbol.

6 7 8

Take out the full water tank on the rear


Remove the plug from the power Remove the outdoor unit if it is attached to side of the air conditioner and empty it.
supply socket. the indoor unit. Then replace it correctly in its position.

9 10 11

5 MIN.
In certain applications a floor drain may
If the dehumidification mode be provided and it may be easier to use • Connect the drain tube to the floor drain
is again required, plug in the unit the drain tube to remove the condensate using a rubber tube.
and wait 5 minutes before water directly. Proceed as follows: After use remember to put the plug into
again turning the mode selector • pull out the 60 mm long condensate the drain tube and to replace
to the dehumidification symbol. drain tube and remove the plug. the tube in its position.

GB - 6
Downloaded from www.Manualslib.com manuals search engine
Fan only
ENGLISH
1 2 3

TURBO

ITALIANO
SILENT

If the air conditioner is to be used in the


fan only mode (ventilation) the outdoor
unit can be placed either outside or Plug the unit in. Turn the mode selector to the high or low
inside the room. Open the air flow direction guide vane. fan speed symbol.

4 5

The unit will now operate in the fan


only mode.
The room air is drawn in through the
side grilles of the air conditioner,
filtered and cleaned and then returned
to the room through the front and rear
air supply grilles.

The fan speed indicator light on the


control panel is illuminated.

Cleaning

OL
PETR

Periodically clean the air filters in the


sides of the unit.
To pull out the filters from their position When bringing the outdoor unit indoors
use the tab on the outside edge. tilt it to drain any remaining condensate.

First clean the filters with a vacuum Empty the remaining condensate water
To clean the appliance use only a damp cleaner then rinse and dry the filters. through the drain tube at the back of
cloth and soap. Reinsert the filters correctly in their the indoor unit, then plug the tube and
Never use spray or flammable liquids. position. stow it.

GB - 7
Downloaded from www.Manualslib.com manuals search engine
In case of…

... the water collection tank is correctly


inserted in its position.
If the unit is not used for extended
periods:
• Empty the remaining condensate water
If the unit appears not to be operating through the drain tube at the back of the
correctly, before calling a service ... the main switch is switched on, that unit.
technician please check that... the power supply is not interrupted and • Clean the filters.
that the unit is correctly plugged in. • Hung the outdoor unit on the back of the
... the operating instructions in the indoor unit.
literature have been followed. ... the filters are not dirty. • Cover the air conditioner

...use of quick-connect
couplings for fixed installation.
TURBO

Models 51AKC013 are provided


Ø 60 mm

with quick coupling connections


that allow the units to be SILENT

disconnected up to a maximum of
six times without impairing the
performance of the air conditioner.
This operation must always be
carried out by qualified and
authorized personnel. Switch the unit off, turning the mode
To disconnect proceed as follows: selector counterclockwise to symbol
and remove the plug from the power
supply socket.

Disconnect the
electrical connector.
Disconnect the
ground wire of the
outdoor section using
a Philips screwdriver.
Loosen the fixing
clamp of the small
tube that takes
condensing water to
the outdoor unit,
taking care to
discharge the
remaining
condensate water
Using the special tool, unscrew the into a pan or the
fixing screw and remove the closing indoor unit collection
cover. tank.

With a screwdriver, unscrew partially the 4 screws of the


fixing bracket flexible pipe.
Using two fixed wrenches (24 mm on turning nut and 19 or
21 mm on fixed parts) operate on the turning nut, unscrew
and remove the quick coupling connections.
Remove the 4 screws of the fixing bracket flexible pipe.
Protect the connection end parts with caps. Position the
outdoor unit outside in the desired position passing the
flexible pipe through the hole (Ø 60 mm) in the wall.
The two parts of the air conditioner should remain split for
the shortest possible time.
For unit re-assembling repeat the previous operations in
reverse order.
For re-connection of the quick coupling, apply a tightening
torque of 23 to 27 Nm.

GB - 8
Downloaded from www.Manualslib.com manuals search engine
L010126H61 - 0405

Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1

The manufacturer reserves the right to change any product specifications without notice.

April, 2005. Supersedes January, 2005. Printed in Italy