You are on page 1of 6

OFFICE OF THE BLDG.

OFFICIAL
LAND USE & ZONING
LOT 14 BLK 6
ROAD
4 LINE & GRADE
1
PERSPECTIVE
ARCHITECTURAL
ROAD
LOT 17
STRUCTURAL
3
SITE 2
LOT 18 BLK 6 SANITARY
SITE DEVELOPMENT PLAN
SCALE: 1:100 M ELECTRICAL
MECHANICAL
VICINITY MAP
2 ( TWO ) STOREY RESIDENTIAL BUILDING MR. AND MRS CIPRIANO M. TAULANI
AS SHOWN
A
JEAN MARGARETTE M. RAVAGO
MULAWIN, ORANI, BATAAN
1
1 2 3 1 2 3
7.00 7.00
3.50 3.50
3.50 3.50
PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE
A A

1.00
sto. LAUNDRY/
D3
1.60

1.60

DIRTY KITCHEN
APEX

1.00
3.00

0.30
PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

OPEN W3
TOP OF RB
W3 SHO. LAV.
1.50

1.50

3.00
W4 W.C D4
W3
W3 BEDROOM 1
PARAPET WALL PARAPET WALL CANOPY

2.70
SINK FIREWALL
D2 CLOSET
2.15

2.15

STOVE

W4
SLAB
SHO. 0.30

1.50
LAV.
W.C 1st FLR. LVL
11.00

C.R
B B
6.00

D2
D3
CLOSET

3.00
SLAB SLAB W5
DINING MASTER'S FIREWALL

3.50
BEDROOM
W3
0.30
5.75

5.75

GF / FFL
RD LVL
PROPERTY LINE
PROPERTY LINE

W2
C C CANOPY
LIVING
R E A R E L E V A T I O N

PROPERTY LINE
1
2.00

SLAB A 1 SCALE 1:1 M

3.50
D1
W1
D D CANOPY
1.46

1.46
PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE
3.50 3.50 3.50 3.50
7.00 7.00
1 SECOND FLOOR PLAN 1 GROUND FLOOR PLAN
A 1 SCALE 1:1 M A 1 SCALE 1:1 M
APEX APEX APEX

1.00

1.00

1.00
PARAPET WALL PARAPET WALL PARAPET WALL
0.30 0.30 0.30
TOP OF RB TOP OF RB TOP OF RB

2.70

2.70

2.70
0.30 0.30 0.30
1st FLR. LVL 1st FLR. LVL 1st FLR. LVL

3.00

3.00

3.00
0.30 0.30 0.30
GF / FFL GF / FFL GF / FFL
RD LVL RD LVL RD LVL
1 LEFT SIDE ELEVATION 1 F R O N T E LE V A TI O N 1 RIGHT SIDE ELEVATION
A 1 SCALE 1:1 M A 1 SCALE 1:1 M A 1 SCALE 1:1 M
2 ( TWO ) STOREY RESIDENTIAL BUILDING MR. AND MRS CIPRIANO M. TAULANI
AS SHOWN
A
JEAN MARGARETTE M. RAVAGO
MULAWIN, ORANI, BATAAN 2
1 2 3 1 2 3
0.40
10mm. DIA. HOR. RSB
7.00 7.00 @EVERY 3 LAYERS OF CHB
10mm DIA. HOR. RSB
@EVERY 3 LAYER OF CHB 5" THK. CHB.
3.50 3.50
3.50 3.50 10mm DIA.VER. RSB
@0.80m O.C
B1 / RB B1 / RB TB / WF TB / WF
A A 5" THK. CHB. 3-10mm. DIA. RSB
1.00
B1 / RB B1 / RB C3F3 TB / WF TB / WF
TB / WF

TB / WF
1.60

1.60

TB / WF 3-10mm. DIA. RSB NGL


C2F2 C2F2
3.00
B1 / RB

B1 / RB

B1 / RB

B1 / RB

TB / WF TB / WF
PROPERTY LINE
SLAB
PROPERTY LINE

TB / WF 10mm. DIA. RSB. TRANSV. BARS 10mm. DIA. RSB TRNSV. BARS
SLAB
SPACED @ 0.30m. O.C
TB / WF

TB / WF
1.50

1.50

SPACED@ 0.30m O.C

3.00
TB / WF

TB / WF

TB / WF

TB / WF
B1 / RB
B1 / RB

B1 / RB
B1 / RB
TB / WF 10 mm Ø TEMP. BARS
SPACED @ 0.40 M.OC
BOTHWAYS
0.40
TB / WF
TB / WF TB / WF
PLAN SECTION
TB / WF

TB / WF
2.15

2.15

TB / WF TB / WF
B2
B2

B2
B2

B2
B2

SLAB SLAB
DETAILS OF WF

1.50
11.00

B1 B1 TB / WF TB / WF
B B SCALE: 1:100 M
6.00

B1 B1 TB / WF TB / WF
C2F2 C1F1 C1F1
0.20
4-12MM Ø HOR. BAR

3.50
10mmØ HOR RSB

TB / WF

TB / WF
0.15
TB / WF

TB / WF

TB / WF

TB / WF
B2
B2

B2
B2

B2
B2

SLAB W/ 10MM STIRRUPS 12mmØ VERT. RSB


10 mm Ø TEMP. BARS SPACED @ 1 - .05, SPACED @ EVERY 3
SPACED @ 0.40 M.OC
@ 0.60 M.OC
5.75

5.75

BOTHWAYS 2 - .10, 3 - .15 LAYER OF CHB


SLAB 10 mm Ø TEMP. BARS
REST @ 0.25MTS O.C.
SPACED @ 0.40 M.OC
PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

BOTHWAYS
B1 TB / WF
C B1
C TB / WF
6-12MM Ø HOR. BAR
W/ 10MM STIRRUPS

TB / WF

TB / WF
C1F1 SPACED @ 1 - .05,
2.00

2 - .10, 3 - .15 REST


RB2
TB / GB1a / GB1b / RB1 @ 0.25MTS O.C.

3.50
6-12MM Ø HOR. BAR
D
B1
B1
D
TB / WF
TB / WF
BEAM DETAILS W/ 10MM STIRRUPS
C2F2 C1F1
SCALE: 1:25
SPACED @ 1 - .05,
1.46

1.46 2 - .10, 3 - .15 REST


@ 0.25MTS O.C.
PROPERTY LINE STRUCTURAL GENERAL NOTES:
PROPERTY LINE 1. GENERAL NOTES & TYPICAL STRUCTURAL DETAILS SHALL APPLY TO ALL
3.50 3.50 3.50 3.50
UNLESS OTHERWISE SHOWN OR NOTED.
2. THE CONTRACTOR SHALL EXAMINE THE DRAWINGS AND SHALL NOTIFY
THE ENGINEER OR ARCHITECT OF ANY DISCREPANCIES HE MAY FIND
TB / WALL DETAIL
7.00 7.00 BEFORE, PROCEEDING WITH THE WORK OR DURING THE CONSTRUCTION.
3. ITS SHALL BE THE CONTRACTORS RESPONSIBILITY TO PROVIDE THE
SCALE: 1:25 M
ADEQUATE SHORING AND BRACING OF STRUCTURE FOR ALL LOADS THAT
MAYBE IMPOSED DURING THE CONSTRUCTION.
4. SPECIAL NOTE: DIMENSIONS INDICATED ON THE STRUCTURAL DRAWINGS
1 F R A M I N G P L A N 1 F O U N D A T I O N P L A N SHALL BE COORDINATED WITH THE ARCHITECTURAL.
DRAWINGS: ARCHITECTURAL DRAWINGS SHALL BE USED TO DETERMINE
A 1 SCALE 1:1 M A 1 SCALE 1:1 M DETAILS CONFIGURATION ELEVATIONS, OPENINGS, JOINTS, SLOPES, ETC.
1.20 1.20 1.20
VARIES VARIES 6-16 mmØ VERTICAL 6-16 mmØ VERTICAL
0.35 0.35 0.35
BARS W/ 10 mm Ø STIRRUPS BARS W/ 10 mm Ø STIRRUPS
6-16 mmØ VERTICAL
BARS W/ 10 mm Ø STIRRUPS
LAP SPLICE ARE ALLOWED LAP SPLICE ARE ALLOWED
L/3 ONLY IN THIS PORTION L/3 L/3 ONLY IN THIS PORTION L/3
6 - 16 mm Ø BOTTOM 6 - 16 mm Ø BOTTOM
6 - 16 mm Ø BOTTOM
BARS BOTHWAYS BARS BOTHWAYS
BARS BOTHWAYS
TYPICAL BEAM DETAIL
SCALE: NTS
6-16 mmØ VERTICAL 6-16 mmØ VERTICAL 6-16 mmØ VERTICAL
BARS W/ 10 mm Ø STIRRUPS BARS W/ 10 mm Ø STIRRUPS BARS W/ 10 mm Ø STIRRUPS
L/7 12mm DIA. LONGITUDINAL BOTTOM 10mm DIA. TOP BARS SPACED @ 0.20m L/7
BARS SPACED @ 0.14M O.C O.C. BOTHWAYS
6 - 16 mm Ø BOTTOM
6 - 16 mm Ø BOTTOM 6 - 16 mm Ø BOTTOM BARS BOTHWAYS
12mm DIA. EXTRA BARS 10mm DIA. TRANSVERSE BOTTOM BARS BOTHWAYS BARS BOTHWAYS
SPACED @ 0.28M O.C BARS SPACED @ 0.20m O.C
BEAM BEAM
L/4 L/2 L/4 0.30 0.30 0.30
L/1
DETAILS OF SLAB
1:100 MTRS.
CF DETAILS
SCALE: 1:25
2 ( TWO ) STOREY RESIDENTIAL BUILDING MR. AND MRS CIPRIANO M. TAULANI
AS SHOWN
S
JEAN MARGARETTE M. RAVAGO
MULAWIN, ORANI, BATAAN 1
1 2 3 1 2 3
7.00 7.00
2"X4" C-PURLINS
3.50 3.50 3.50 3.50
2"X2" TOP & BOTTOM
PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE
ANGLE BAR
A
1.60

1.60

GA # 26 PRE-PAINTED
3.00

3.00
HT1 HT1 HT1 HT1 HT1 HT1
LONG SPAN ROOFING
1.50

1.50

2-2"X4" C-FACIA
PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

PROPERTY LINE

PARAPET WALL PARAPET WALL CANOPY PARAPET WALL PARAPET WALL CANOPY
A 11 2 " X 1 1 2" WEB MEMBER
2.15

2.15

ANGLE BAR
SLAB SLAB
PURLINS
3" DIA. PVC DOWNSPOUT ON
B
BLOW -UP DETAILS GA #26 PRE-PAINTED GUTTER
6.00

6.00
SCALE: NTS W/ WIRE MESH
SLAB SLAB SLAB SLAB
5.75

5.75

B C
PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

PROPERTY LINE
2.00

2.00
SLAB SLAB
D
1.46

1.46
C PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE
3.50 3.50 3.50 3.50 3.07
7.00 7.00
D
1 R O O F F R A M I N G 1 R O O F P L A N 1
H T 1 D E T A I L S
A 1 SCALE 1:1 M A 1 SCALE 1:1 M A 1 SCALE 1:1 M
1.00 0.80 0.80 1.00
1.50 1.50 1.20 0.50 1.50 0.60
1 W INDOW S SC H EDULE 1 D O O R S S C H E D U L E
A 1 SCALE 1:1 M A 1 SCALE 1:1 M
2 ( TWO ) STOREY RESIDENTIAL BUILDING MR. AND MRS CIPRIANO M. TAULANI
AS SHOWN
S
JEAN MARGARETTE M. RAVAGO
MULAWIN, ORANI, BATAAN 2
1 2 3
7.00
2.50
3.50 3.50
PROPERTY LINE PROPERTY LINE
A
1.00

sto. LAUNDRY/
1.60

DIRTY KITCHEN
SHO. LAV.
1.50

3.00

W.C
PROPERTY LINE

S.V
SINK
PLAN
2.15

LAV.
SHO. 1.45 0.90
1.50

LAV.
W.C
11.00

C.R
B W.C
3.50
5.75

PLUMBING ISOMETRIC LAYOUT


SCALE: NTS
C CANOPY
3.50

D
PROPERTY LINE

CANOPY SV 0.40
1.46

SECTION
PROPERTY LINE
SEPTIC VAULT DETAIL
TO MAIN
SEWER
3.50 3.50 0.50
SCALE: 1:30 M
7.00 0.11
0.28
0.11
1 P L U M B I N G L A Y O U T
A 1 SCALE 1:1 M
GENERAL NOTES:
GRADES OF HORIZONTAL PIPINGS RUN ALL HORIZONTAL PIPINGS IN PERPECT ALIGNMENT AND AT A FORM GRADE
NOT LESS THAN TWO PERCENT (2).
CHANGE IN DIRECTION ALL CHANGE IN DIRECTION SHALL BE MADE BY APPROPRIATE USE OF FORTY-FIVE DEGREES (45°)
WYES, LONG SWEEP QUARTER BEND, SIXTH-EIIGHT OR SIXTEENTH BEND. WHEN THE CHANGE OF FLOW IS FROM
PLAN
HORIZONTAL TO VERTICAL A SINGLE 1/8 BEND COMBINATION MAYBE USED ON VERTICAL STACKS AND SHORT QUARTER
BENDS MAYBE USED ON WASTE LINE, TEE AND CROSSES MAYBE USED IN BENT PIPES.
LEGEND: PROHIBITED FITTINGS NO DOUBLE HUB OR TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL AND WASTE LINES, THE
DRILLINGS AND TAPPING OF HOUSE DRAIN, WASTE OR VENT PIPES AND USED OF SADDLE HUB AND BEND ARE
GATE VALVE
WATER METER PIPE CLEAN-OUTS
SEWER LINE CLEAN-OUTS ARE REQUIRED UNDER THE FOLLOWING CONDITIONS:
WATER LINE a) EVERY CHANGE OF HORIZONTAL DIRECTION EXCEEDING TWENTY TWO AND ONE-HALF DEGREES (22 1/2 ).
CO CLEAN OUT b) ONE AND ONE-HALF METERS (1.50m) INSIDE THE PROPERTY LINES BEFORE THE HOUSE DRAINAGE CONNECTION.
LAV LAVATORY c) EVERY FIFTEEN METERS (15.00m) IN HORIZONTAL RUN OF PIPES.
SHO SHOWER d) AT THE END OF ANY HORIZONTAL PIPE LINES. SECTION
FD FLOOR DRAIN
WC
KS
WATER CLOSET
KITCHEN SINK
SEPTIC VAULT

THE DIGESTION CHAMBER OF SEPTIC VAULT MUST BE WATERPROOFED.


NOT LESS THAN 0.30 METER OF AIR SPACE MUST BE LEFT BETWEEN THE TOP OF THE SEWAGE AND THE UNDER PART OF
CATCH BASIN DETAIL
SV VAULT ROOF SLAB. SCALE: 1:30 M
NO SEPTIC VAULT SHALL BE CONSTRUCTED UNDER THE BUILDING.
ALL PLUMBING WORKS SHALL BE UNDER THE SUPRVISION OF A LICENSED MASTER PLUMBER AND A LICENCED PLUMBING
CONTRACTOR.
2 ( TWO ) STOREY RESIDENTIAL BUILDING MR. AND MRS CIPRIANO M. TAULANI
AS SHOWN
P
JEAN MARGARETTE M. RAVAGO
MULAWIN, ORANI, BATAAN 1
7.00 7.00 7.00 7.00
3.50 3.50 3.50 3.50
3.50 3.50 3.50 3.50
PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE

1.00
1.00

S1
7
1.60

1.60
3
1.60

1.60

S1
S2

3.00
3.00

S1 6

PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

5
EF
4 S1
1.50

1.50
1.50

1.50

3.00
3.00

PARAPET WALL PARAPET WALL


1
EF
S1
2.15

2.15
2.15

2.15

SLAB SLAB EF

1.50
1.50

11.00
11.00

11.00

C.R C.R
S1

6.00
S2
6.00

12.46
S2
SLAB SLAB SLAB SLAB

3.50
3.50

5.75

5.75
5.75

5.75

PROPERTY LINE
PROPERTY LINE

PROPERTY LINE
PROPERTY LINE

S2

PROPERTY LINE
PROPERTY LINE

2.00
2.00

SLAB SLAB

3.50
3.50
CANOPY CANOPY

1.46

1.46
1.46

1.46

M
PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE
3.50 3.50 3.50 3.50 3.50 3.50 3.50 3.50
7.00 7.00 7.00 7.00
1
2nd FLR. LIGHTING LAYOUT 1
1st FLR. LIGHTING LAYOUT 1
2nd FLR. POWER LAYOUT 1
1st FLR. POWER LAYOUT
A 1 SCALE 1:1 M A 1 SCALE 1:1 M A 1 SCALE 1:1 M A 1 SCALE 1:1 M
SCHEDULE OF LOAD ELECTRICAL GENERAL NOTES:
1. ALL ELECTRICAL WORKS HEREIN SHALL BE EXECUTED IN ACCORDANCE
M WITH THE LATEST EDITION OF THE PHIL. ELECTRICAL CODE (PEC). THE NEW
C.K.T. NO. QTY DESCRIPTION W V A
AMPERE
PROTECTION SIZE OF WIRE & SIZE OF CONDUIT
ELECTRICAL ENGINEERING LAW (R.A. 7920). LAWS AND ORDINANCES OF THE
LOCAL GOVERNMENT UNIT AND RESOLUTIONS OF THE LOCAL POWER UTILITY COMPANY
1 7 LIGHTING OUTLET 700 220 3.18 15A 2
2-2.0 mm THHN @ 15mm Ø 2. ALL WIRING SHALL BE IN RIGID STEEL CONDUIT FOR SERVICE LINES AND PVC
FOR LOAD SIDE CONDUIT IN CONFORMANCE WITH EXISTING ELECTRICAL CODE
2 8 LIGHTING OUTLET 800 220 3.63 15A 2
2-2.0 mm THHN @ 15mm Ø MAIN ACB:
30 AT, 2P,230V LEGEND: 3. PANEL BOARDS AND OVERCURRENT PROTECTION ENCLOSURES SHALL BE
NEMA-1 FOR INDOOR AND NEMA-3 FOR OUTDOOR USE,UNLESS S[ECIFIED
3 8 LIGHTING OUTLET 800 220 3.63 15A 2
2-2.0 mm THHN @ 15mm Ø 15 AT 20 AT
SERVICE ENTRACE 4. POWER SERVICE TO THE BUILDING SHALL 230V.,60Hz.,2-WIRE, 1 PHASE.
4 4 LIGHTING OUTLET 400 220 1.81 15A 2
2-2.0 mm THHN @ 15mm Ø
LIGHTING OUTLET 1 20 AT 20 AT
2 LIGHTING OUTLET
CONTROL PANEL
5. ALL WIRING INSTALLATION SHALL BE CONCEALED FROM VIEW
6. UNLESS OTHERWISE INDICATED BRANCH CIRCUIT CONDUCTORS SHALL NOT BE
SMALLER THAN 2.0 mm DIA. SOLID COPPER,MEDIUM DRAWN,TW TYPE 600 VOLTS
5 13 CONVENIENCE OUTLET 2340 220 10.63 20A 2-3.5 mm 2 THHN @ 15mmØ LIGHTING OUTLET 3 4 LIGHTING OUTLET M WATT METER
7. MINIMUM SIZE OF CONDUCT SHALL BE 25 mm DIA. FOR RCS 20mm FOR PVC
6 3 CONVENIENCE OUTLET 540 220 2.45 20A 2-3.5 mm 2 THHN @ 15mmØ LIGHTING OUTLET
CONVENIENCE OUTLET 5 6 CONVENIENCE OUTLET
CONVENIENCE OUTLET
8. NO BRANCH CIRCUIT CONDUCTORS SHALL BE LOADED MORE THAN 80% OF
ITS RATED CAPACITY
7 1 ACU 2300 220 10.45 20A 2-3.5 mm 2 THHN @ 15mmØ 2
9. EMPTY CONDUIT OF SIZE AS REQUIRED,SHALL BE PROVIDED IN PANEL BOARD
ACU ACU
7 8 1 C.K.T NUMBER
UNLESS OTHERWISE NOTED
8 1 ACU 2300 220 10.45 20A 2-3.5 mm 2 THHN @ 15mmØ ACU
10. MOUNTING HEIGHT OF PANEL AND DIVICES ARE AS FOLLOW:
POWER LINE
9 1 SPARE 2000 220 9.09 20A 2-3.5 mm 2 THHN @ 15mmØ
SPARE 9 10 SPARE
S1 ONE GANG SWITCH A. WALL SWITCHES 1400 mm
S2 TWO GANG SWITCH B. WALL CONVENIENCE OUTLET 300 mm
C. COUNTER TOP OUTLET 300 mm
10 1 SPARE 2000 220 9.09 20A 2-3.5 mm 2 THHN @ 15mmØ S3 THREE GANG SWITCH
D. WALL AIR CONDITIONER OUT 300 mm
E. PANEL BOARD 1830 mm
MAIN / TOTAL 64.41 11. CONDUIT /RACES SHALL BE ADEQUATELY SUPPORTED AS REQUIRED AIN CONFORMANCE
WITH THE CURRENT ELECTRICAL CODE.
12. DISTRIBUTION PANEL SHALL BE READILY ACCESSIBLE THAT NO OBSTACLE SHOULD
TOTAL COMPUTATION: BLOCK ACCESS TO THE CIRCUIT BREAKER OF FUSES.
(64.41 X 80% D.F.) + ( 25 % X 10 ) =54.02 AMP.
USE: 60 AMPS A.F. MOULDED CASE CIRCUIT BREAKER ( MAIN ) ONE-LINE DIAGRAM 13. SUPERVISION OF THE INSTALLATION SHALL BE DIRECTLY ADMINISTERED BY A DULY
LICENSED ELECTRICAL PRATITIONER IN CONFORMANCE WITH R. A. 7920
USE: 2- 14 mm² THHN @ 30 mm Ø
2 ( TWO ) STOREY RESIDENTIAL BUILDING MR. AND MRS CIPRIANO M. TAULANI
AS SHOWN
E
LEOPOLDO M. HERNANDEZ JR.
MULAWIN, ORANI, BATAAN 1