DX330 L/M/V

SERIES
Universal Intelligent Controller for Screw Air Compressor
Please experience DOTECH’s technology based on simplicity,
multi-function and safety!!

Easier
Faster
Safer

DOTECH, INC http://www.dotech21.com


DX330
DX330 efficiently controls screw type air compressor based on microprocessor, gives users an alarm
against trip by checking the status of the machine in advance and offers users the information for
maintenance and let them treat it quickly and easily.
Also, it is the cutting-edge electronic controller mounted with VSD (Variable Speed Drive) based on
PID control system, which can help users to save more than maximum 30% of the energy costs.

- Reducing the energy costs using VSD (Variable Speed Drive)


Using inverter, the revolution of motor can be freely set up by either a microprocessor or users,
so it is possible to start and stop flexibly. Also, it has users reduce energy cost by getting efficient and
economic operation cost comparing with existing air compressor with other controllers.
- Applying for the large size graphic LCD displayed by multi-language (Korean, English, Chinese and Japanese, etc.)
- Easy analyzing for the trouble by storing up to maximum 160 numbers of trip alarm history (Black box function)
- Notifying the information and expected time for PM (preventative & maintenance)
and exchanging RSP (recommended spare parts) schedule
- Automatic recovering from CPU down caused by noise
- Various analogue output function (Inverter speed control, discharged pressure & air temperature transmission, etc.)
- Establishing the most optimized system embedding high-function and high-efficiency in spite of monolithic small size
- Providing perfect interface with upper systems by mounting RS485 communication,
MODBUS RTU international standard protocol

INVERTER OUTPUT

45.0 Hz COMPUTER
TOUCH SCREEN

INVERTER

45
7.5 24.8
18:20
지열출구저온
02

DX330

K
M
C

45
7.5 24.8
18:20
지열출구저온
02

AIR COMPRESSOR
le as e ex pe ri en ce D O TECH’s technology
P
our best to
which is always doing
pr oa ch to yo u ba se d on the best
ap
y
function and reliabilit
oller!!
in field of digital contr

DOTECH, INC

Model Types

Input Ouput
Type Communications Real Time Clock
Digital Temperature 4~20mAdc Digital Analog

L 10 1 1 4 X RS 485(1)
DX330
M 10 3 2 12 X RS 485(1) O

V 10 3 2 12 3 RS 485(2) O

Basic Specification

Power Input Power AC24V 50/60Hz, DC24V CPU ATmega 128, 16MHz
CPU, LCD
Specification Power
Max. 20VA LCD 240 X 128 pixel, LED Backlight
Consumption
Storage
Installation Installation Place Indoor Installation Temperature -30 ~ 80 ℃
Environmen Operation Environmen Operation
Temperature -10 ~ 60 ℃ Humidity No Condensation 5 ~ 95%

Related Product Information

DX380 Multi-Compressor Control Unit (Maximum 8sets)

DA - 32 Multi-Compressor Control Unit (Maximum 32sets, Touch Screen Type)

DA -100 DX330 Monitoring & Trend System

Related Product DPR-TH020-P6D100L : Discharge Air Temperature, Oil Reclaimer Temperature.


Information Exclusive Temperature Sensor
DPR-TH1-ET : Ambient Temperature Sensor

Pressure Sensor DP500 Series : Discharge Air Pressure, Oil Reclaimer Pressure

DX330 Exclusive Transformer 24069001 : AC220V / 24(30VA)


Wiring Diagram MAX AC240V
330M,V Model

30

330M,V Model

Inverter
330V Moel

330V Model

DOTECH,INC. http://www.dotech21.com 6F, JOONGANG-ILBO, 778 Wonsi-Dong, Danwon-Gu, Ansan-Si,


DOTECH
SENSING & CONTROL business@dotech21.com Gyeonggi-Do, Korea TEL : +82-31-495-3767 / FAX : +82-31-495-3917
Menu Structure

00:Operation State 01: Basic Operation Setup 02: Operation Plan Setup 03: Trip Alarm History 04:PM Information 05: Trip Range Setup 06:Alarm Ran

00: Discharge Temp. 00: Unload Pressure 00: Sun. Run-Stop Event #1 00: Dust Filter cleaning 00: Discharge Temp. High 00: Discharge Te

01: Discharge Press. 01: Load Pressure 01: Mon. Run-Stop Event #2 01: Suction Filter change 01: Discharge Press. High 01: Discharge Pr

02: Ambient Temp. 02: Auto-stop Delay Time 02: Tue. Run-Stop Event #3 02: Oil Filter change 02: Oil Reclaimer Temp. High 02: Oil Reclaime

03: Oil Reclaimer Press. 03: Manual Stop Delay Time 03: Wed. Run-Stop l 03: Lub. Oil change 03: Oil Reclaimer Press. High 03: Oil Reclaime

04: Oil Reclaimer Temp. 04: Start Delay Time 04: Thu. Run-Stop Event #160 04: Cooler Cleaning 04: Differential Press. High 04: Differential P

05: Differential Press. 05: Drain Time 05: Fri. Run-Stop 05: Overhaul 05: Ambient Tem

06: Total Run Hours 06: Drain Interval 06: Sat. Run-Stop * Possibility to display
TILL, PASS, EXCEED and
07: Motor Run Hours 07: Cooling Fan Run Temp.
CYCLE for PM
08: Motor On/Off Times 08: Cooling Fan Stop Temp.
09: Loaded Hours 09: LCD Backlight Mode
10: LoadingTimes
11: Inverter Control ★
12: Discharge Press.
Retrans. ★
13: Discharge Temp.
Retrans. ★
※ The indication of ‘★’ is only available for DX330V.

Discharge Air Temperature


Display for Operation State
Run Hours
Loaded Hours
bar ℃

45
Load / Unload Ratio (%)

7.5
Discharge Pressure State Ambient Temperature
Oil Pressure
Oil Temperature
Inverter Controlled Output
Load 123 h
Current Time
Digital Output State CM CY CD SOL NP N10 N11 N12 08: 20 Counted Time
Alarm Message
Run / Stop Mode LOC PRE EMER STAND-BY Equipment Operation State
Run / Stop Information,
Flickering
Digital Input State EMS OFC OCC REV OFP AFP OAP AEL AES 02 Equipment Operation Code Loc RUN Loc STP
Net RUN Net STP
Rem RUN Rem STP
Loaded Run Mode Equipment State Lock Signal
S.D STP
(GOOD, MAINTEN, ALARM, S-DOWN, INHIBIT)

When you push key, it shows run hours, loaded hours, load / unload duty ratio, ambient temperature, oil reclaimer temperature,
oil reclaimer pressure, inverter output, frequency in shifts.

Basic Operation Setup


▶ Unload Pressure : 7.0 bar
Load Pressure : 6.5 bar
Menu Constitution
Auto-Stop Delay Time : 300 h
Menu Selection Manual Stop Delay Time : 30 h
Operation State Start Delay Time Setup : 10 h
Basic Operation Setup
Operation Plan Setup
Trip Alarm History
Trip Alarm History
00 040102 15:55 Initial Power Input
01 040102 16:10 Operation Start
02 040102 16:30 Fan Motor Overload
03 040102 16:30 Operation Start
04 040102 16:45 X Fan Motor Overload Trip Alarm State
Fan Motor Overload 040102 16:30
In Operation(Y/D) Ambient Temperature: 30℃
Discharge Air : 4.5bar 35℃
ID (10~1):
N (12~1):
ge Setup 07: Failure Setup 08:Operation Method Setup 09: VSD Operation Setup ★ 10: Manual Test Mode 11: Equipment 12: Delivery
Environment Setup Environment Setup

emp. High 00: Discharge 00: Y-Delta Transfer Time 00: VSD Control Mode 00: Manual Operation Mode 00: Trip Alarm History Delete 00: Test Mode
ress. High Temp. Low 01: Load Delay Time 01: Maximum Speed 01: Compressor Motor MCM 01: Operation Record Delete 01: B1 Input
r Temp. High 01: Oil Reclaimer 02: Reload Delay Time 02: Minimum Speed 02: Compressor Motor MS 02: Ambient Temp. Sensor Use 02: B2 Input
r Press. High Press. Low 03: Differential Press. 03: Optimum Speed 03: Compressor Motor MD 03: Oil Reclaimer Press. Use 03: B3 Input
Detect Delay 04: Unloaded Speed
Press. High 04: Load SOL. Valve Output 04: Oil Reclaimer Temp. Use 04: B4 Input
04: Load Commend Mode 05: Current Speed
mp. High Command (Hz) 05: Multi Function N9 05: Discharge Press. Correction 05: B5 Input
05: Starting Mode 06: Multi Function N10 06: Oil Reclaimer Press. Correction 06: B4 4mA
06: mA Output Value
06: Power Return Restart 07: Multi Function N11 07: Ambient Temp. Correction 07: B4 20mA
07: Proportional Band
07: Network ID 08: Integral Time 08: Multi Function N12 08: Discharge Temp. Correction 08: B5 4mA
08: Network BPS 09: Dead Band 09: Inverter Control ★ 09: Oil Reclaimer Temp. Correction 09: B5 20mA
10: Jerk Ratio 10: Discharge Press. 10: Min. Discharge Press. 10: Y1 4mA ★
11: Inverter Speed Range Retrans. ★
11: Max. Discharge Press. 11: Y1 20mA ★
12: Inverter Maximum 11: Discharge Temp.
12: Min. Oil Reclaimer Press. 12: Y2 4mA ★
Frequency Retrans. ★
13: Max. Oil Reclaimer Press. 13: Y2 20mA ★
14: Multi Function N9 14: Y3 4mA ★
15: Multi Function N10 15: Y3 20mA ★
16: Multi Function N11 16: ADC F/T
17: Multi Function N12 17: DAC F/T

Dimensions

230
23 45 204
20

Cutout Size : 192 X 130 (mm)


150
15

90
Mount Hole : 5pie X 4 EA

Operation Button Function

Run/Stop Run (Green) or Stop (Red)

Reset during trip


Reset (The trip having automatic reset function is not necessary
to Pushing the button)

Menu Go to “setup” and/or “state” when pushing the button

Enter Select or Save

UP/DOWN Upward (Increase) and/or Downward (Decrease)

Cancel Return to the previous menu or the initial screen