FILTRATION
FA-1 series
Spin-on filters
Technical Information
Filtrec elements are tested also according to ISO 2942, ISO 23181 and ISO 3968
w w w. f i l t r e c . c o m FA-1 series
Ordering information
SUCTION (n.b. for return & inline see page 6)
LINE
MEDIA
000 no element
C10 cellulose ß10 µm (C) >2
C25 cellulose ß25 µm (C) >2
G10 microglass fiber ß12 µm (C) >1000
G25 microglass fiber ß27 µm (C) >1000
T60 wire mesh 60 µm
T125 wire mesh 125 µm
ELEMENT
SEALS
B NBR
CONNECTION
BY-PASS
0 no by-pass
S 0,25 bar / 3,6 psi
00 no indicator
R7 pressure/vacuum gauge -1÷5 bar /-14,5÷72,5 psi
S1 vacuum gauge indicator scale 0÷-1 bar / 0÷-14,5 psi
S4 visual vacuum switch -0,2 bar /-2,9 psi
S13 vacuum switch -0,2 bar / -2,9 psi SPDT
FA-1 series
2
Overall dimensions
FA-1-10/11 FA-1-20/21
L1
L1
B1
B1
A
A
A
A
ØA1
ØA2
H1
H1
H2
H2
ØA1
L2
L2
R
element removal R
element removal
B2
Ø F x Depth Ø F x Depth
FA-1-30/31 FA-1-40/41
B2
ØA1
B1
ØA2
H1
H2
2 MOUNTING HOLES
Ø F x Depth
H1
ØA2 ØA2
A
ØA1 ØA1
H2
L2
ØA2
H1
H2
ØA1
R
L2 element removal
3 MOUNTING HOLES
R
element removal Ø F x Depth
L1
Indicator port 1/8”
L1
B3
B1
D1
Nominal size
CODE A A1 A2 B1 B2 B3 D1 F H1 L1 R WEIGHT ELEMENT H2 L2
FA-1-10 3/4” 3/4” 192 1,3 Kg A-1-10 148 96
--- 22 38 95 20
FA-1-11 BSP BSP 257 1,5 Kg A-1-11 213 96
M8x15
FA-1-20 1 1/4” 1 1/4” 1 1/2” 249 1,9 Kg A-1-20 182 128
30 50 --- --- 133
FA-1-21 BSP BSP 16-UN 295 2,2 Kg A-1-21 228 128
FA-1-30 1 1/2” 218 3,6 Kg 2x A-1-20
70 65 140 40
FA-1-31 BSP 262 3,8 Kg 2x A-1-21
--- --- M10x15 ---
FA-1-40 1 1/2” 267 5,0 Kg 2x A-1-20
46 150 60 284 132
FA-1-41 BSP 313 5,2 Kg 2x A-1-21
For different thread options please contact Filtrec Customer Service. FA-1 series
3
Pressure drop diagrams
The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow
rate. This ideally should not exceed 0,2 bar (2,9psi).
PRESSURE DROP THROUGH Housing
THE FILTER HOUSING
Flow rate (gpm)
∆p (bar)
∆p (psi)
3
∆p (bar)
∆p (psi)
∆p (psi)
Flow rate (l/min) Flow rate (l/min)
∆p (bar)
∆p (psi)
∆p (psi)
∆p (psi)
The above diagrams have been obtained at the FILTREC laboratory, according to the ISO 3968 specification, with mineral oil having 30 cSt
viscosity and 0,86 Kg/dm3 density.
In case of discrepancy, please check contamination level, viscosity and features of the oil in use and the sampling points of the differential
pressure.
FA-1 series
4
Clogging indicator
The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by
the filter element.
The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value
setting.
N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator
alarm must be considered at normal working temperature only.
30 Ø40
SYMBOL CODE SCALE
1/8” BSP
12
Housing in black ABS material
Multipurpose product: this gauge can also be used as pressure gauge
on return filters.
VACUUM GAUGE
1/8” BSP
30 Preferential option
VACUUM SWITCH
SPDT CONTACTS
FA-1series
5
Ordering information
000 no element
G03 microglass fiber ß4,5 µm (C) >1000
G06 microglass fiber ß7 µm (C) >1000
G10 microglass fiber ß12 µm (C) >1000
G25 microglass fiber ß27 µm (C) >1000
C10 cellulose ß10 µm (C) >2
C25 cellulose ß25 µm (C) >2
ELEMENT
SEALS
B NBR
CONNECTION
BY-PASS
0 no by-pass
R 1,7 bar/ 24,6 psi
00 no indicator
R6 visual pressure switch 1,3 bar / 18,9 psi
R7 pressure/vacuum gauge -1÷5 bar /-14,5÷72,5 psi
R9 pressure gauge 0÷4 bar / 0÷58 psi
R12 pressure gauge indicator scale 0÷16 bar / 0÷232 psi
R13 pressure switch 1,3 bar / 18,9 psi SPDT
Z1 differential visual indicator 1,3 bar / 18,9 psi
For FA-1-3x only
Z2 differential electric visual indicator 1,3 bar / 18,9 psi
For FA-1-4x only Z20 differential visual indicator 1,3 bar / 18,9 psi
FA-1 series
6
Overall dimensions
FA-1-10/11 FA-1-20/21
L1
L1
B1
B1
A
A
A
A
ØA1
H1
ØA2
H1
H2
H2
ØA1
L2
L2
R
element removal R
element removal
Indicator port 1/8”
Indicator port 1/8”
2 MOUNTING HOLES
Ø F x Depth
B2
2 MOUNTING HOLES
B2
Ø F x Depth
FA-1-30/31 FA-1-40/41
B2
ØA1
B1
ØA2
H1
H2
2 MOUNTING HOLES
Ø F x Depth
H1
ØA2 ØA2
ØA1 ØA1
H2
L2
ØA2
H1
H2
ØA1
R
L2 element removal
R 3 MOUNTING HOLES
element removal Ø F x Depth Differential indicator port
B2
D1
Nominal size
CODE A A1 A2 B1 B2 B3 D1 F H1 L1 R WEIGHT ELEMENT H2 L2
FA-1-10 3/4” 3/4” 192 1,3 Kg A-1-10 148 96
--- 22 38 95 20
FA-1-11 BSP BSP 257 1,5 Kg A-1-11 213 96
M8x15
FA-1-20 1 1/4” 1 1/4” 1 1/2” 249 1,9 Kg A-1-20 182 128
30 50 --- --- 133
FA-1-21 BSP BSP 16-UN 295 2,2 Kg A-1-21 228 128
FA-1-30 1 1/2” 218 3,6 Kg 2x A-1-20
70 65 140 40
FA-1-31 BSP 262 3,8 Kg 2x A-1-21
--- --- M10x15 ---
FA-1-40 1 1/2” 267 5,0 Kg 2x A-1-20
46 150 60 284 132
FA-1-41 BSP 313 5,2 Kg 2x A-1-21
For different thread options please contact Filtrec Customer Service.
FA-1 series
7
Pressure drop diagrams
The total Pressure Drop (Dp) value is obtained by adding the Dp values of filter housing and filter element at the given flow
rate. This ideally should not exceed 0,5 bar (7,2psi).
PRESSURE DROP THROUGH Housing
THE FILTER HOUSING
Flow rate (gpm)
∆p (bar)
∆p (psi)
The Pressure Drop through the filter element is related
both to the internal diameter of the filter element and to
the filter media; this value is affected by the oil viscosi-
ty in a roughly proportional way: e.g. when the Dp
value from the curve is 0,2 bar and a 46 cSt oil is used,
Flow rate (l/min)
the corresponding value is 0,31(=0,2 x 46/30) bar.
Element A-1-10-.. Element A-1-11-..
Flow rate (gpm) Flow rate (gpm)
∆p (bar)
∆p (bar)
∆p (psi)
∆p (psi)
Flow rate (l/min) Flow rate (l/min)
∆p (bar)
∆p (psi)
∆p (psi)
∆p (psi)
1.6 24
16
0.8
8
0.0
0 60 120 180 240 300
Flow rate (l/min)
The above diagrams have been obtained at the FILTREC laboratory, according to the ISO 3968 specification, with mineral oil having 30 cSt
viscosity and 0,86 Kg/dm3 density.
In case of discrepancy, please check contamination level, viscosity and features of the oil in use and the sampling points of the differential
pressure.
FA-1 series
8
Clogging indicator
The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by
the filter element.
The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value
setting.
N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator
alarm must be considered at normal working temperature only.
The clogging indicator registers the pressure upstream the filter element:
•with the VISUAL indicator a value higher than 1,3 bar indicates the need of element replacement.
•with the ELECTRIC indicator an electrical switch is activated when the set value 1,3 bar is reached.
1/8” BSP
30
PRESSURE GAUGE
PRESSURE SWITCH
SPDT CONTACTS
BSP
• AC: 250 V 3 A inductive, 2 A resistive contacts switch only, simply connecting 1 and
• Protection: IP65, connector DIN43650 3 or 1 and 2 only, respectively.
• SPDT contacts
Preferential option
FA-1series
9
Clogging indicator
The Pressure Drop (Dp) through the filter increases during the system operation due to the contaminant retained by
the filter element.
The filter element must be replaced when the indicator shows an alarm and before the Dp reaches the by-pass value
setting.
N.B. in cold start conditions a false alarm can be caused by higher oil viscosity due to low temperature; the indicator
alarm must be considered at normal working temperature only.
The differential clogging indicator registers the pressure upstream and downstream the filter element and activates a
signal when the differential pressure reaches the set value:
•in the VISUAL indicator the signal is given by a green sector switching into red.
•in the ELECTRIC VISUAL indicator, further to the green to red visual indication, an electrical switch is activated.
N.B. the set value of the clogging indicator must always be lower than the set value of the by-pass valve.
Ø30
SYMBOL CODE SETTING
Z1 1,3 bar (18,9 psi)
38
30
Visual indicator:
28
O-RING
O-RING 30
M20x1,5
• Max voltage: 250V AC - 30V DC
Ø28
SYMBOL CODE SETTING
Z20 1,3 bar (18,9psi)
24
33
Visual indicator:
23
M18x1,5
FA-1 series
10
User Tips
FIXING HOLES
IDENTIFICATION LABEL
IN
BY-PASS VALVE
BOWL TIGHTENING TORQUE
FILTER HEAD OUT
FA-1-xx 3/4 turn
INDICATOR PORT
INDICATOR TIGHTENING TORQUE
R6-R7-R9-R12-R13
30 Nm
S1-S2-S3-S4
Z1-Z2-Z20 30 Nm
FILTER CARTRIDGE
Installation Maintenance
Make sure that the filter is connected in the correct Before unscrewing the cartridge, ensure that the
IN-OUT flow direction (shown by an arrow on the system is switched off and there is no residual
filter head). pressure in the filter.
The filter housing should be preferably mounted with Unscrew the cartridge by turning it anticlockwise.
the bowl downward; the filter head should be Verify the correct part number of the FILTREC replace-
properly secured using the threaded fixing holes on ment cartridge, particularly concerning the micron
the filter head; verify that no tension is present on the rating. Ensure that the mounting face is clean, lubrica-
filter after mounting. te the gasket of the replacement cartridge prior to
Make sure that enough space is available for element assembly. Spin on new cartridge until it reaches the
replacement and that the clogging indicator is in a mounting face and tighten for 3/4 turn.
easily viewable position. If an electrical indicator is
used, make sure that it is properly wired.
Never run the system without a filter element fitted.
We recommend the stocking of a spare FILTREC
filter element for timely replacement when required.
WARNING
Make sure that Personal Protective Equipment (PPE) is worn during installation and maintenance operation.
FA-1 series
11
CT05-rev.02-03/17