You are on page 1of 3

AD26.20-W-4002A Electronic power shift (EPS) diagnosis fault memory (fauld code list) 11.11.

97
TRANSMISSION 714.4 in MODEL 650.###, 651.###, 652.###, 653.###, 654.### ## as of 957417
TRANSMISSION 714.7, 715.2 in MODEL 655.###, 656.###, 657.###, 658.###, 659.### ## as of 962863

p When repairing, no control units (with MB part


end number 19, 20, 13 and 14) for old cabling
should be installed with new cabling!
Electronic power shift (EPS), diagnosis AD26.20-W-2001C
previous knowledge
Fault memory
Fault code A Possible cause Note Test step / remedy
EPS EPS
display display
with FDS,
HHT
0 200 Control unit Troubleshooting with HHT AD26.20-W-6001-35C
and 79 I79
I I0I Splitter solenoid valve 1 (MS1) - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-10B
Socket box test AD26.20-W-6001-55A
2 I02 Splitter solenoid valve 2 (MS2) - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-10C
Socket box test AD26.20-W-6001-55A
3 203 Solenoid valve MUB - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-08B
Socket box test AD26.20-W-6001-55A
4 204 Solenoid valve MUE - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-08C
Socket box test AD26.20-W-6001-55A
5 205 Solenoid valve MGB - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-08D
Socket box test AD26.20-W-6001-55A
6 206 Solenoid valve MGE - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-08E
Socket box test AD26.20-W-6001-55A
7 207 Solenoid valve MG1 - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-09B
Socket box test AD26.20-W-6001-55A
8 208 Solenoid valve MG2 - Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-09C
Socket box test AD26.20-W-6001-55A
9 209 Solenoid valve MR1 -* Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-11B
Socket box test AD26.20-W-6001-55A
I0 2I0 Solenoid valve MR2 -* Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-11C
Socket box test AD26.20-W-6001-55A
II III Splitter sensor (SSP) - Troubleshooting with HHT AD26.20-W-6001-05B

© Daimler AG, 6/29/17, G/06/16, ad26.20-w-4002a, Electronic power shift (EPS) diagnosis fault memory (fauld code list) Page 1 of 3
TRANSMISSION 714.4 in MODEL 650.###, 651.###, 652.###, 653.###, 654.### ## as of 957417 TRANSMISSION 714.7, 715.2 in MODEL 655.###, 656.###, 657.###, 658.###, 659.### ## as ...
Socket box test AD26.20-W-6001-05D
I2 2I2 Gear sensor (SGG) - Troubleshooting with HHT AD26.20-W-6001-02B
Socket box test AD26.20-W-6001-02D
I3 2I3 Gate sensor (SGE) - Troubleshooting with HHT AD26.20-W-6001-04B
Socket box test AD26.20-W-6001-04D
I4 2I4 Range sensor (SRA) - Troubleshooting with HHT AD26.20-W-6001-03B
Socket box test AD26.20-W-6001-03D
I5 2I5 Clutch sensor (SKU) - Troubleshooting with HHT AD26.20-W-6001-01B
Socket box test AD26.20-W-6001-01D
I6 2I6 Shift control unit voltage - Troubleshooting with HHT AD26.20-W-6001-06D
Actual values (with HHT only) AD26.20-W-3005-01A
Socket box test AD26.20-W-6001-06F
AD26.20-W-6001-06G
AD26.20-W-6001-06H
I7 II7 Splitter solenoid valve 1 (MS1) -//-, ( +) Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-10D
Socket box test AD26.20-W-6001-55A
AD26.20-W-6001-57A
I8 II8 Splitter solenoid valve 2 (MS2) -//-, ( +) Only recognized as current fault during
actuation of defective circuit (with
corresponding shift process).
Troubleshooting with HHT AD26.20-W-6001-10E
Socket box test AD26.20-W-6001-55A
AD26.20-W-6001-57A
I9 2I9 Solenoid valve MUB -//- Fault code can also be triggered by brief
short-circuit to positive (e.g. with short-circuit
to another solenoid valve cable, affected
solenoid valve is temporarily actuated as
well).
Troubleshooting with HHT AD26.20-W-6001-08F
Socket box test AD26.20-W-6001-55A
20 220 Solenoid valve MUE -//- Fault code can also be triggered by brief
short-circuit to positive (e.g. with short-circuit
to another solenoid valve cable, affected
solenoid valve is temporarily actuated as
well).
Troubleshooting with HHT AD26.20-W-6001-08G
Socket box test AD26.20-W-6001-55A
2I 22I Solenoid valve MGB -//- Fault code can also be triggered by brief
short-circuit to positive (e.g. with short-circuit
to another solenoid valve cable, affected
solenoid valve is temporarily actuated as
well).
Troubleshooting with HHT AD26.20-W-6001-08H
Socket box test AD26.20-W-6001-55A
22 222 Solenoid valve MGE -//- Fault code can also be triggered by brief
short-circuit to positive (e.g. with short-circuit
to another solenoid valve cable, affected
solenoid valve is temporarily actuated as
well).
Troubleshooting with HHT AD26.20-W-6001-08I
Socket box test AD26.20-W-6001-55A

23 223 Solenoid valve MG1 -//-, + Troubleshooting with HHT AD26.20-W-6001-09D


Socket box test AD26.20-W-6001-55A
AD26.20-W-6001-57A
24 224 Solenoid valve MG2 -//-, + Troubleshooting with HHT AD26.20-W-6001-09E
Socket box test AD26.20-W-6001-55A
AD26.20-W-6001-57A
25 225 Solenoid valve MR1 -//- Fault code can also be triggered by brief
short-circuit to positive (e.g. with short-circuit
to another solenoid valve cable, affected
solenoid valve is temporarily actuated as
well).
Troubleshooting with HHT AD26.20-W-6001-11D
Socket box test AD26.20-W-6001-55A
26 226 Solenoid valve MR2 -//- Fault code can also be triggered by brief
short-circuit to positive (e.g. with short-circuit
to another solenoid valve cable, affected
solenoid valve is temporarily actuated as
well).
© Daimler AG, 6/29/17, G/06/16, ad26.20-w-4002a, Electronic power shift (EPS) diagnosis fault memory (fauld code list) Page 2 of 3
TRANSMISSION 714.4 in MODEL 650.###, 651.###, 652.###, 653.###, 654.### ## as of 957417 TRANSMISSION 714.7, 715.2 in MODEL 655.###, 656.###, 657.###, 658.###, 659.### ## as ...
Troubleshooting with HHT AD26.20-W-6001-11E
Socket box test AD26.20-W-6001-55A
27 I27 Splitter sensor (SSP) -//-, + Troubleshooting with HHT AD26.20-W-6001-05C
Socket box test AD26.20-W-6001-05D
AD26.20-W-6001-05E
28 228 Gear sensor (SGG) -//-, + Troubleshooting with HHT AD26.20-W-6001-02C
Socket box test AD26.20-W-6001-02D
AD26.20-W-6001-02E
29 229 Gate sensor (SGE) -//-, + Troubleshooting with HHT AD26.20-W-6001-04C
Socket box test AD26.20-W-6001-04D
AD26.20-W-6001-04E
30 230 Range sensor (SRA) -//-, + Troubleshooting with HHT AD26.20-W-6001-03C

Socket box test AD26.20-W-6001-03D


AD26.20-W-6001-03E
3I 23I Clutch sensor (SKU) -//-, + Troubleshooting with HHT AD26.20-W-6001-01C
Socket box test AD26.20-W-6001-01D
AD26.20-W-6001-01E
27-3I I27 mit Splitter sensor, gear, gate, range, clutch -//-, Troubleshooting with HHT AD26.20-W-6001-05C
+
228-23I
Socket box test AD26.20-W-6001-56A
32 232 Shift control unit voltage -//-, + Troubleshooting with HHT AD26.20-W-6001-06E
Actual values (with HHT only) AD26.20-W-3005-01A
Socket box test AD26.20-W-6001-06F
AD26.20-W-6001-06G
AD26.20-W-6001-06H

© Daimler AG, 6/29/17, G/06/16, ad26.20-w-4002a, Electronic power shift (EPS) diagnosis fault memory (fauld code list) Page 3 of 3
TRANSMISSION 714.4 in MODEL 650.###, 651.###, 652.###, 653.###, 654.### ## as of 957417 TRANSMISSION 714.7, 715.2 in MODEL 655.###, 656.###, 657.###, 658.###, 659.### ## as ...

You might also like