Allengers High Frequency C-Arm's are incorporated using the latest state-of-the-art "High Frequency Technology (40
KHz)", in which there is minimal production of non useful / harmful X-Rays thus providing the user with the following
advantages :

Advantage of HF Generators:
Gives 70%-80% more output. Set KV
(Line Frequency)
40 KV 2 Pulse
Negligible soft-radiation hence skin dose is low. High Ripple
0 1 CYCLE
Output wave form is practically constant at peak
value, thus the output is very efficient.
Less exposure time is required to obtain the Set KV
(High Frequency)
optimum dose for a particular radiograph. 14 KHz
40 KV
The HF X-Ray generator also ensures exact Medium Ripple
0 1 CYCLE
reproducibility of exposure parameters.

Set KV
(High Frequency)
Useful X-Rays 40 KV 40 KHz
Low Ripple
Skin Dose 0 1 CYCLE
X-Rays Not Useful

We strongly recommend the following


Models for special applications :
Allengers HF 46/49 - ORTHO & General applications.
Allengers HF 49R - URO, GASTRO, NEURO &
SPINAL injuries.

Specially designed to fulfill most demanding


application of Surgeons & Technicians.
Innovative Features Include :
Self diagnostic program to cut the service downtime of equipment.
Back-up circuitry for enhanced performance & reliability.
Feather touch control panel for ease of operation & disinfection.
Automatic Brightness Stabilizer (ABS) - to enable one to see the best image.
Thermal safety of tube head monoblock.
Full compatibility with ESWL.
Iris collimator with/without parallel shutter (optional).
Laser centering device (optional).
Dose area product meter (optional).
After sale service - lightening response with a solution. 64 Frame Memory with Trolley
CONTROL PANEL
Our various C-Arm models have very compact soft touch control panels employing
Micro-Processor circuitry for unparalleled reliability & the symbolic switches
makes them highly user friendly.

24 23

0.1 0.2 0.3 0.5 0.6

2 S 22

COLLIMATOR
-HF49 0.8 1.0 1.5 2.0 3.0
21
X-RAY O/L
3 MODE

FLUORO
RDY EXP 20
EMERGENCY FLUORO
1 2 3 4 5

4
SELF DIAGNOSTICS 19
6 7 8 9 10
WARNING : THIS X- RAY UNIT MAY BE DANGEROUS TO THE
PATIENT AND THE OPERATOR UNLESS SAFE EXPOSURE
FACTORS AND OPERATING INSTRUCTIONS ARE OBSERVED

6 ON OFF HD EXP

7
mA KV
9" 6" 4.5"
8 F R 000 ABS

9 10 11 12 13 14 15 16 17 18

1. C-Arm up/down switches on 13. Fluoro mA display.


both sides of console.
14. KV (inc/dec) switches.
2. Collimator control switches.
15. KV display.
3. Pulse fluoro selection switch
with indicators. 16. Automatic Brightness Stabilizer
(ABS) switch/indicator.
4. Switches/Indicators for (L/R,
U/D) movements of image. 17. High definition fluoro ON
5. Image rotation switches. switch / indicator.

6. Machine ON switch. 18. High definition fluoro


exposure switch.
7. Machine OFF switch/indicator.
8. Mode selection (F/R) 19. Self diagnostic indicators.
switch/indicators. 20. Emergency fluoro (ready /
9. Fluoro exposure switch. exposure) switches.
10. Fluoro timer reset switch. 21. X-Ray & Overload indicators.
11. Fluoro timer display. 22. Radiographic mAs display.
12. I.I. mode selection switch with 23. mAs (inc/dec) selection switches.
indicators [Normal, (Zoom-1,
Zoom-2 incase of multi field I.I.)]. 24. X-Ray switch (radiography).
MAJOR TECHNICAL SPECIFICATIONS

Allengers HF-46 Allengers HF-49 Allengers HF-46R Allengers HF - 49R


PARAMETERS (Upgradable to DSA)
HF X-Ray Generator 40 KHz. High Freq. 40 KHz. High Freq. 40 KHz. High Freq. 40 KHz. High Freq.
Max Power Output 3.5 KW 3.5 KW 6 KW 6 KW
Fluoro / Radiographic KV 40 to 110 KV 40 to 110 KV 40 to 120 KV 40 to 120 KV
Fluoro mA (Normal Mode) 0.1 to 3 mA 0.1 to 3 mA 0.1 to 5 mA 0.1 to 5 mA
Fluoro Timer 5 min. cumulative 5 min. cumulative 5 min. cumulative 5 min. cumulative
Radiographic mA 30 mA 30 mA 30 to 100 mA 30 to 100 mA
Radiographic Timer 0.1 to 3 seconds 0.1 to 3 seconds 0.1 to 3 seconds 0.1 to 3 seconds
H. D. Mode (Max. mA) 7.5 mA 7.5 mA 10 mA 10 mA
(Optional)

Tube Head Mono block with stn. Mono block with stn. Mono block with rot. Mono block with rot.
(Monoblock) anode X-Ray tube anode X-Ray tube anode X-Ray tube anode X-Ray tube
X-Ray Tube Focal Spots Dual Dual Dual Dual
Focal Spot Size Small : 0.6 mm2 Small : 0.6 mm2 Small : 0.3 mm2 Small : 0.3 mm2
Large : 1.5 mm2 Large : 1.5 mm2 Large : 0.6 mm2 Large : 0.6 mm2

Imaging System
Image Intensifier Tube 6" (150 mm) 9"(230 mm) 6" (150 mm) 9" (230mm) Triple
with Power Supply Unit Dual field (optional) Triple field Dual field (optional) field (very high res.)
X-Ray Round Grid 6" - 8:1, 100 LPI 9" - 8:1, 100 LPI 6" - 8:1, 100 LPI 9" - 8:1, 100 LPI
OPTIONAL : 12" I. I.

CCD Camera ½" B/W CCD camera of very high resolution with special lens, CCIR standard - 625 lines

Monitors (2 Nos.) 15" Monitors of high resolution with image rotation mounted on a mobile trolley.
For HF49 / HF49 R - 17" / 19" CRT / LCD Monitors - Optional. (Monitor type & size
is user selectable).

IMAGE MEMORY

The C-Arms can be supplied with any one of the following Image Memories as per users intended applications:

64 Frame Memory (64 F) : Last image hold, recursive filter, negative image & I.R. remote.

100 Frame Memory (PS 100) : With this the data can be transferred to a PC for permanent storage.

Digital Image Processor (DIP) : Having frame grabber card & special medical imaging software with 10,000 image
storage, CD writer, offline digital subtraction, roadmap contrast enhancement, quad view, patient I.D. etc.

Specialized Models:
C-Arm with DIP-IQ imaging Memory.

C-Arm with 1K x 1K format.


(for detailed specifications please refer product data sheet).

The C-Arms can be configured & supplied in different combinations of image intensifiers,
CCD cameras, monitors, image memories as per users specifications.
DIMENSIONS

Mobile Trolley

317
WIG WAG MOVEMENT
12.5
0
485
824

25
0
12.50

1220
700

1093 ~ 1313

Orbital Movement
900+300

Rotational
Movement
3600
R560
Horizontal Center
Movement 220 mm R485
1760 ~ 2190

of C
50

950

92.7
577.5
Vertical Movement
430 mm
430

FOCAL
50

SPOT
160

159

1208 566 ~ 786


1774 ~ 1994
Net weight : 410 Kg (Appx.)
All Dimensions in mm.

C-ARM MECHANICALS
Focus Screen Distance 950 mm Wig Wag (Panning) ± 12.50 (250 total)

Clearance 800 mm C-Arm Rotation 3600

Vertical Movement of 'C' (Motorized) 430 mm Arc Orbital Movement 900+300


(Circ. Movement)
Horizontal Movement 220 mm

OTHER FEATURES POWER REQUIREMENT


- Steering handle for movement. - Foot operated Lock for C-Arm. 230V AC (±10%), Single phase,
- Emergency Stop. - Exposure Indicator. - Foot Switch. 50/60 Hz., 15 Amps,
- Locks for wig wag, Horizontal, Circular & Rotational movements. Independent Earthing.

For detailed technical specifications, please refer to the respective product data sheets / quotation.
QUALITY & SAFETY CERTIFICATIONS

Passion For Excellence...


Our Leading Edge

Represented by:
AMSL/VOL-7(04/10)

MANUFACTURED & MARKETED BY:

ALLENGERS MEDICAL SYSTEMS LTD.


S.C.O. 212-213-214, SECTOR 34-A, CHANDIGARH -U.T. 160 022 (INDIA) www.allengers.com
DOMESTIC SALES : INTERNATIONAL SALES : EUROPEAN REPRESENTATIVE :
Ph : +91 172 3012280-84 Ph : +91 172 3012285, 3012287 JMC Medical Sprl (Mr. Jean Marc Claeys)
Fax : +91 172 2621913 Fax : +91 172 2621912 58, Avenue du Parc de Woluwe, B-1160 Bruxelles, Belgium
sales@allengers.net exports@allengers.net Tel. : 00/32.2.672.56.44 Fax : 00/32.3.662.29.92 E-mail : jmc@beon.be

For detailed technical specifications, please refer to the respective product data sheets / quotation.
Due to continuous product improvements, specifications and appearance are subject to change without prior notice.

You might also like