You are on page 1of 54

SHEER

LEVEL MEASUREMENT INSTRUMENTS POWER 159

Level Measurement
Instruments
Our level instruments offering continues to grow to meet your application needs. Lesman can provide you with every-
thing from the simplest float-type mechanical switch to radar level transmitters that work in tanks obstructed by ladders,
mixers, and baffles. Not sure which will fit your process best? We can help. Just fill out an level application datasheet and
fax it to us. We’ll review your information and help you find the perfect instrumentation to fit your process.

Due to manufacturer agreements, not all products are available in all geographic areas and markets.

Flow Measurement
Prices See Due to manufacturer agreements, not all products

Instruments
are available in all geographic areas and markets.
Start at Page

Switches
GEMS Bottle and Float Switches $104 160
Kobold Float-Type Level Switches $23 161
Siemens CLS100 Two-Wire Capacitance Point Level Switch $163 164
Siemens CLS200 Capacitance Point Level Detection Switches $305 166

Solids Flow and Motion


Siemens CLS300 Capacitance Point Level Switches for Harsh Environments $425 168
Siemens CLS500 Capacitance Point Level Switch for Extreme Conditions $465 170
Siemens LPS200 Rotating Paddle Switch for Bulk Solids $245 162
Siemens LVS200 Vibrating Fork Switch for Bulk Solids $370 163
Siemens ULS200 Ultrasonic Point Level Detection Switch $620 172

Transmitters
Honeywell ST3000 Flange Mount Smart Transmitter for Liquid Level $1503 181
MTS Sensors Magnetostrictive Gauges for Liquids Level $1200 178
Sartorius (formerly GWT) PanCake® Load Cells for Level by Weight Call 174

Rotary and Electric


Actuator Motors
Siemens EnviroRanger ERS500 Liquid Level Monitor $1520 193
Siemens Hydroranger 200 Wastewater Monitoring and Control System $1195 192
Siemens MiniRanger Plus Single-Channel Continuous Level Transceiver $810 187
Siemens MultiRanger 100/200 Ultrasonic Continuous Level Transceivers $1175 170
Siemens Probe Ultrasonic Continuous Level Transmitter for Liquid Level $750 186
Siemens SITRANS LC300 Capacitance Continuous Level Transmitters $492 182
Siemens SITRANS LC500 Capacitance Continuous Level Transmitters $465 184
Siemens SITRANS LR200 Radar for Continuous Bulk Liquid Storage Levels $1155 204

Combustion Safety
Siemens SITRANS LR300 Microwave Pulse Radar for Continuous Level $1595 206

and Efficiency
Siemens SITRANS LR400 Long Range FM Radar for Difficult Applications $2790 209
Siemens SITRANS LU01/LU02 Long Range Ultrasonic Transceivers $1600 194
Siemens SITRANS LU10 Multipoint Long Range Ultrasonic Transceiver $4480 196
Siemens SITRANS Probe LR Radar for Liquid Level $995 203
Siemens SITRANS Probe LU Ultrasonic Transmitter for Liquid Level $800 188
Siemens SITRANS P DS III Pressure Transmitter as a Bubbler for Liquid Level $2990 180
Siemens SITRANS P MPS Submersible Pressure Transmitter for Liquid Level $380 177
US Filter Loop Powered Submersible Level Transmitter $700 177
and Communications
Wireless Instruments

WIKA LS-10 Submersible Transmitter for Liquid Level $349 176

Accessories
Siemens Echomax Ultrasonic Level Transducers $365 198
Siemens FMS Series Mounting Brackets for Echomax Ultrasonic Sensors $95 200
Siemens SIMATIC PDM Configuration Software Utility $70 147
Siemens SmartLinx™ Communications Interface Modules $510 201
FLOAT Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
160 SWITCHES Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Low-Cost Float-Type Level Switches


Assemble Your Own 1- or 2-Station High Reliability in a Low-Cost Switch
Level Switch with Fabri-Level® Kits 1/8”
NPT
With a 1” diameter float, this switch
is ex­tremely compact and ideal for use
Contains everything you need for where space is limited. Polysulphone
complete assembly of a 1- or 2-station models are best suited to water-based,
level switch unit for pipe-plug mount- neutral liquids, and offer highly
9/16”
ing in a tank.
Flow Measurement

reliable SPST, 20VA switch­ing at


Each Kit Contains: a low cost. Switch action can be
Instruments

1 Tube Connector set normally open or nor­mally


1 9/16” closed by inverting the float on
1 Tube End Fitting
the unit’s stem.
1 Mounting Plug (2” NPT) 1”
2 Extension Tubes (10”) Model Selection Guide
2 Level Stations (Switch, Wetted Specific Pressure Operating Catalog
Tube, and Float) Material Gravity Max. Temp (°F) Number Price
3 Tube Unions Polypropylene 0.72 min. 150 PSI -40° to 150° NCP-2554 $23.00
Solids Flow and Motion

Model Selection Guide


GEMS Fabri-Level® Switch Kit Catalog No. Price Stainless Steel Float Stands
Brass Fittings/Buna-N Floats 24576 $297.00
All 316 Stainless Steel Fittings/Floats 24577 621.00 Up to Extreme Conditions
Turn up the heat (to 300° F max.) — no
sweat! With its 316 stainless steel stem
General Purpose Float Switches mount and float, this SPST, 20VA switch
handles pressures up to 400 PSI with a 0.73
Buna-N floats deliver excellent buoyancy and long life in minimumliquid specific gravity.
most water and oil applications. Reed switches are housed
in rugged brass or stainless steel stems. NCB series switches Model Selection Guide
support operating temperatures to 180°F for oil, 225°F Specific Operating Catalog
for water, as well as a maximum pressure of 150 PSI. Gravity Temp. °F Number Price
Rotary and Electric
Actuator Motors

NCB-1054: Compact float and mount for tight spaces. 0.73 min. -40° to 300° NCS-5214 $74.00
NCB-1000: 1/8” mount and a mid-sized float for greater * Actuation level nominal (based on 1.0 liquid specific
buoyancy force. gravity and N.O. dry circuit — dimension will vary for
N.C. circuit).
NCB-4000: Largest float displacement for highest buoyant
forces. Larger stem and mount withstand rough service.
Great for high viscosity liquids. Floats for Small Tanks
Model Selection Guide Size makes this SPST 20VA float switch ideal for shal-
Stem/Mount Material
low tanks or restricted spaces.Pressure and temperature
Float Size Specific (‑40° to 300° F) capa­bilities are better than with Buna-N
(H x Dia.) Gravity Switch Brass Stainless Steel
or engineered plastic floats.
1” Sq. 0.50 min. 20 VA, SPST NCB-1064 $37.00 NCB-1054 $52.00
Combustion Safety

1.75” x 1.2” 0.58 min. 100 VA, SPST NCB-1094 46.00 NCB-1084 56.00 Model Selection Guide
and Efficiency

1.88” Sq. 0.55 min. 100 VA, SPST NCB-5134 56.00 NCB-5124 68.00 Specific Pressure Catalog
Gravity Max. Number Price
0.80 min. 150 PSI NCS-1074 $44.00
Bottle Switch Solves Access Problems
Bottle-type level switches are great for large
tanks, or where access to the inside is impractical or Stop Nuisance Switching
impossible.These units mount completely outside of Liquids sloshing around can cause a float to bob up
the tank, at the level actuation point. Think of them and down rapidly, if the liquid surface is in contact with
as an ideal working enviroment — totally removed the float.This creates nuisance switching, an off/on condi-
from the goings-on inside your tank. tion that wears on your patience and your reed switch. A
and Communications
Wireless Instruments

Brass housing and 316 stainless steel float are suit- slosh shield creates a pocket of calm liquid, so the switch
able for use in oil- or water-based liquids. Set these can operate as designed.
switches for N.O. or N.C. oper­ation by inverting the Construction: Wetted materials: Stainless steel, beryllium
float in the unit stem. copper, nickel, Buna-N. Slosh shield: Lucite
Environment: Operating tem- Model Selection Guide
Model Selection Guide perature: -40° to 140° F. Min.
Float Specific Pressure Operating Catalog Catalog
liquid specific gravity: 0.55. Max. Shielded Switch Number Price
Material Gravity Max. Temp (°F) Number Price pressure: 150 PSI
Normally Open 43765 $104.00
316 SS 0.75 min. 500 PSI -40° to 300° 172625 $191.00 Switch: SPST, 20 VA Normally Closed 43760 104.00
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan FLOAT

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
SWITCHES 161

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Float-Type Level Switches
Tethered Float Switches for Liquid Level 5.90”
1”
Kobold tethered float switches can easily moni- • For all types of liquids
tor liquid levels. You can use pairs of these float
switches to control fill levels, using one for minimum limit and • SPTD mercury switch
one for maximum. • Polyethylene or Teflon
NSP and NST switches can be installed wherever magnetic liquid • Temperatures to 320°F,

Flow Measurement
level switches are unsuitable due to the risks of the float jamming Pressures to 30 PSIG
with dirt particles or media buildup and deposits on the float.

Instruments
The float consists of a hollow cylinder with an integral SPTD Need a float switch
contact switch, which can be connected as normally open or in stainless steel or 2.17”
normally closed. The contact operates when the level rises above polypropylene? Call us.
or falls below the horizontal float position. The switching point is
fixed by installing the switch horizontally at the required position, 4.72”
or by clamping the cable to the tank or vessel. Model Selection Guide
Material Maximum Catalog
NSP models come standard with 6 feet of PVC cable, but canbe
Float Cable Cladding Pressure Temperature Number Price
ordered with Silicone, Oilflex, or Teflon cable. NST models come
with 6 feet of Teflon-coated PVC cable, but can be ordered with Polyethylene PVC 30 PSIG 190°F NSP-5101 $137.00

Solids Flow and Motion


Teflon Teflon 15 PSIG 320°F NST-5101 728.00
all-Teflon cable instead.

Side-Mounting Level Switches for High/low level control systems are easy
Inaccessible Tank Tops and Bottoms with GEMS components!
Flip-Pak®: 120 VAC, 5Amp, control
• Low cost, compact design pumps, motors, solenoid valves,
• NEMA 4 brass or stainless and more!
steel housing, 304 SS float Automated control for only $99.00!
• Factory-set normally Order model number 28196.
open switch contact;
Move the reed switch for normally closed action

Rotary and Electric


Actuator Motors
• Maximum pressure to 230 PSIG Mount anywhere along
vertical section of the tank.
Chemical-Resistant Level Switch
Kobold NV liquid level switches can be
installed wherever a compact device is
needed for monitoring fluid levels.
A cylindrical 304 stainless steel float is
located at one end of a horizontal balance
arm. Float movements are transmitted through the balance arm to a permanent • Perfect for tanks with inacces-
magnet at the opposite end, which then actuates a reed contact located within a sible tops or bottoms
moveable brass or stainless steel housing. • NEMA 6 protection rating

Combustion Safety
The reed contact switches on or off depending on the position of the permanent • Great chemical resistance: Polypropylene or PVDF

and Efficiency
magnet and the switch housing. The SPST switch is set as normally open at the
factory, but can be set to normally closed in the field. • Maintenance-free, easy to install
• Normally open or normally closed switch contact
Specifications
Specifications
Maximum Conditions: Temperature: 230° F; Pressure: 230 PSIG
Maximum Operating Conditions: Temperature: Polypro­pylene:
Process Connection: 1/2” or 3/4” NPT 175°F;PVDF:212°F;Pressure: 145 PSIG;Fluid Density: Poly­propylene:
Materials: Housing and sleeve: Brass or 304 SS; Float, plate spring, and bellows: 304 SS; 0.6 g/ml; PVDF: 0.95 g/ml
Contact sleeve: Polyamid; Cable: 5 ft. PVC; O-ring: Brass units: Buna-N, SS units: Viton Materials: Float, housing: Polypropylene or PVDF; Fittings: 1/2”
Reed Switch: SPST, N/O (factory-set), or N/C; Max. contact rating: 60 VA, 60 watt; 250 NPT or bulkhead; Orientation: Horizontal ±30°; Cable: 3 ft. PVC,
VAC @ 2A AWG 20/2
and Communications
Wireless Instruments

Reed Switch: Gas encapsulated; N/O or N/C; Max. voltage: 250 VAC;
Model Selection Guide Max. Current: 1.5A; Max. power: 50 watts
Float Size Specific Min. Fluid Housing Material
Model Selection Guide
L x Diam. Gravity Density Brass Stainless Steel
Housing Fittings Catalog Number Price
1” x 0.87” 0.75 min. 0.72 g/ml NV-5101 $156.00 NV-5201 $214.00
Polypropylene 1/2” NPT NKP-2401 $30.00
2” x 0.87” 0.66 min. 0.63 g/ml NV-5103 156.00 NV-5203 221.00 Bulkhead NKP-6401 30.00
PVDF 1/2” NPT NKP-2501 57.00
Bulkhead NKP-6501 57.00
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
162 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Rotary Paddle Switch for Bulk Solids


SITRANS LPS200 Paddle Switch
• Proven paddle switch technology for bulk solids
• High integrity mechanical switch
• Switch-selectable power supply
• Unique friction clutch mechanism prevents damage caused by falling materials
Flow Measurement

• Stainless steel 1-1/4” NPT or 1-1/2” BSP threaded connection


Instruments

• Hinged paddle option for use with low-density materials


• Simple installation through process connection — Either paddle fits into small threaded
nozzle — fits where other manufacturer’s models won’t
• High temperature model and optional extension kit available
How It Works:
• Motorized paddle rotates in free air • Transferred torque activates switch
• Material contact stops rotation • Clutch avoids gear failure/replacement
Solids Flow and Motion

The new SITRANS LPS200 is an electromechanical rotary paddle switch Ordering Instructions
for level detection of powder and granular solids. Make one selection from each table section below. Check the availability
The paddle switch technology detects full, empty, or demand condi- column to be sure the unit you need is available. A finished catalog number
tions on materials like grain, feed, cement, plastic granulate, and wood looks like this: 7ML5710-1AA31-1AA0
chips. The LPS paddle switch can handle bulk densities as low as 100 g/l
with the standard measuring vane , or 35g/l with the hinged vane. Please submit orders to: Siemens,
Model Selection Guide c/o Lesman Instrument Company
A low revolution geared motor with slip clutch drives a rotating vane Avail-
that senses the presence of material at the LPS mounted level. As mate- Description Model ability Price
rial comes into contact with the rotating paddle, rotation stops, which All models come standard with stainless steel 1.25” NPT threaded process con-
changes the microswitch state. When the paddle is no longer covered, nection and CSA, FM, and ATEX approvals
rotation resumes and the relay reverts to its normal condition.
Rotary and Electric

LPS200 Rotating Paddle Switch: Compact Length 7ML5710- ↓ $245.00


Actuator Motors

The LPS200 comes in a variety of configurations, including compact, LPS200 Rotating Paddle Switch: Extended Length 7ML5712- ↓ 270.00
extended, and cable extension. The LPS200 standard vane is effective Input Switch Selectable, 1 Rev/Min 1 _ _ _ _- • • 0.00
in most applications, or it can be configured with a hinged vane for Voltage Switch Selectable, 5 Rev/Min 2 _ _ _ _- • • 0.00
increased sensitivity for light materials. Process Up to 176°F (80°C) _ A _ _ _- • • 0.00
Temperature Up to 428°F (220°C) _ B _ _ _- • 170.00
Specifications Process Up to 7.25 PSI _ _ A31- • • 0.00
Temperature: -4° to 176°F (-20° to 80°C); Optional: -4° to 428°F (-20° to 220°C) Pressure Up to 145 PSI _ _ B31- a a 0.00
Max. Pressure: 7 PSI (0.5 bar); Optional: 145 PSI (10 bar) Extension Standard Length 6.5” 1 _ _ _ • 0.00
Length Standard length 8.5” 1 _ _ _ • 0.00
Minimum Material Density (depends on shaft/vane coverage): Standard
Vane: 100 to 200 g/l; Hinged Vane: 35 to 70 g/l Measuring Boot Shaped, 35 x 106mm _ AA0 • • 0.00
Vane Hinged Vane, 65 x 210mm _ BA0 • • 35.00
Power: Jumper selectable; 115 VAC, ±15%, 50-60 Hz, 4 VA, 230 VAC, ±15%, 50
Combustion Safety

Hz, 6 VA, or 24 VDC, ±15%, 2.5 W Note A: Not available with process temperature option B.
and Efficiency

Alarm Output:Relay 5A at 250 VAC, noninductive Description Model Price


Material: Enclosure: Epoxy coated aluminum, NEMA 4/IP65; Process connec­ LPS200 Cable Extension Version 7ML5714- $305.00
tion: 1-1/4” NPT, stainless steel; Conduit entry: 2 x 1/2” NPT; Measuring shaft Input Switch Selectable, 1 Rev/Min 1 _ _ _ _- 0.00
and vane: Stainless steel Voltage Switch Selectable, 5 Rev/Min 2 _ _ _ _- 0.00
Approvals: FM/CSA Class II, Div. 2, Groups E–G; Process Up to 176°F (80°C) _ A _ _ _- 0.00
ATEX II 1/2 D (dust explosion); CE Temperature Up to 428°F (220°C) _ B _ _ _- 170.00
Process Up to 7.25 PSI _ _ A31- 0.00
Accessories Pressure Up to 145 PSI (Note A) _ _ B31- 0.00
Catalog Measuring Boot Shaped, 35 x 106mm 1 _ _ _ 0.00
and Communications
Wireless Instruments

Description Number Price Vane Hinged Vane, 65 x 210mm 2 _ _ _ 35.00


Instruction Manual 7ML1998-5FS61 $10.00 Extension Standard Length, 2000 mm _ AA0 0.00
Motor Gear/PLC-Multivoltage 7ML1830-1KG 115.00 Cable Length 1000–2000 mm _ BA0 35.00
Replacement Vane, Boot Shape, 35 x 106 mm 7ML1830-1KH 10.00 Add a Z to the end Cable Length 2050–3000 mm _ CA0 45.00
Hinged Vane, 65 x 210 mm 7ML1830-1KJ 40.00 of the model number, Cable Length 3050–4000 mm _ DA0 55.00
Rope Extension Kit, 2M 7ML1830-1KK 140.00 and on the next line, Cable Length 4050–5000 mm _ EA0 65.00
add Code Y01: Total Cable Length 5050–6000mm _ FA0 75.00
Rigid Extension Kit: Spring coupling, rigid tube extension, and required pins. Insertion Length= Cable Length 6060–7000mm _GA0 85.00
500, 400, and 300mm 7ML5711-0AA 30.00 ”(length) mm.” Cable Length 7050–10000mm _HA0 115.00
Length 1000, 900, 800, 700, and 600 mm 7ML5711-1AA 40.00 Note A: Not available with process temperature option B.
1500, 1400, 1300, 1200, and 1100mm 7ML5711-2AA 50.00
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578 POINT LEVEL 163

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Vibrating Fork Switch for Bulk Solids
SITRANS LVS200 Vibratory Switch
• High resistance to mechanical forces • Low frequency, low energy operation
• Suitable for low density materials: standard • Best self-cleaning properties
version 20 g/l (1.3 PCF), liquids/solids inter- • Won’t burrow into the material
face version 60 g/l (3 PCF)
• High or low level alarm in solids — Simple
• Extension lengths to 4000mm (157”)

Flow Measurement
failsafe high/low selection

Instruments
Vibrating Fork Technology
As soon as you apply power, the LVS200 forks material contact,and the resulting signal falls below
vibrate. The forks are very active and sensitive at the sensitivity threshold.
the tip — not at the base — to help resist detecting The forks vibrate at a high amplitude or displace-
material buildup between the forks. ment, but with low energy. This ensures reliable
A dual crystal pack is directly coupled to the detection of even the lightest material, and avoids
vibrating legs to generate high amplitude, low the tendency to burrow and lose contact.
frequency (125 Hz) vibration, providing optimum The factory sensitivity setting suits most ap-
self-cleaning characteristics during operation.

Solids Flow and Motion


plications, especially for light materials. For higher
A third passive crystal senses the fork vibration. density materials, the operating sensitivity can be
Relays activate when fork vibration is damped by switched lower to avoid some material adhesion.

The SITRANS LVS200 is an electromechanical vibratory switch for level Ordering Instructions
detection of powder and granular solids. Make one selection from each table section below. Check the availability
The SITRANS LVS200 is an excellent solution for low bulk density, low column to be sure the unit you need is available. A finished catalog number
humidity/adhesion, and free flowing applications. This unit is ideal for looks like this: 7ML5720-1AB11-0AA0
new installations or for replacing: Please submit orders to: Siemens,
• Diaphragm-based switches subject to rupture Model Selection Guide c/o Lesman Instrument Company

• Problematic rotating paddle switches Description Model Price


All models come standard with19–235 VAC, 19–55 VDC input voltage, 1.5” NPT
• Electrostatic discharge sensitive switches

Rotary and Electric


threaded process connection, and CSA, FM, and ATEX approvals.

Actuator Motors
• Material dielectric sensitive switches SITRANS LVS200 Vibrating Point Level Switch 7ML5720- $370.00
• Switches that require special application configuration or multiple Extension Standard Length, 230 mm -1AB11- 0.00
The standard LVS200 detects high or low levels of dry bulk solids in Extension Length 300–500 mm -1AB12- 225.00
Add a Z to the end Extension Length 550–750 mm -1AB13- 225.00
bins, silos, or hoppers. The liquid/solid interface version can also detect of the model number, Extension Length 800–1000 mm -1AB14- 225.00
settled solids within liquids or solids in confined spaces, like feed pipes. and on the next line, Extension Length 1050–1250 mm -1AB15- 300.00
It is designed to ignore liquids in order to detect the interface between add Code Y01: Total Extension Length 1300–1500 mm -1AB16- 335.00
a solid and a liquid. A pipe extension version is available with either the Insertion Length= Extension Length 1550–1750 mm -1AB17- 375.00
standard or liquid/solid interface electronics and fork, separated by a ”(length) mm.” Extension Length 1800–2000 mm -1AB18- 410.00
customer-supplied 1” pipe. Extension Length 2050–2250 mm -1AB21- 450.00
Use 50mm Extension Length 2300–2500 mm -1AB22- 485.00
The LVS has a compact design, and can be top- or side-mounted. The increments. Extension Length 2550–2750 mm -1AB23- 525.00

Combustion Safety
vibrating fork design ensures the lines are kept clean. The unique design Extension Length 2800–3000 mm -1AB24- 560.00

and Efficiency
of the fork and crystal assembly eliminates false high level readings. Extension Length 3050–3250 mm -1AB25- 600.00
Extension Length 3300–3500 mm -1AB26- 635.00
Extension Length 3550–3750 mm -1AB27- 675.00
Specifications Extension Length 3800–4000 mm -1AB28- 710.00
Material Density: 20 g/l (1.3 lb/ft3) min.; Liquid/Solid interface version: 60
Catalog
g/l (3 lb/ft3) Description Number Price
Process Temperature: -40° to 302°F (-40° to 150°C); CSA Class II, Group G: -40° These models come standard with19–235 VAC, 19–55 VDC input voltage,
to 284°F (-40° to 140°C), CSA temperature code T3B stainless steel 1.5” NPT threaded process connection, and CE approval. 1” pipe
Pressure: 145 PSI maximum extensions supplied by customer.
Sensitivity: High or low, switch selectable SITRANS LVS200 Pipe Extended Model 7ML5724-1AB11- $575.00
and Communications

Application Dry Bulk Solids (125 Hz) 1AA0 0.00


Wireless Instruments

Measuring Frequency: 125 Hz; Liquid/Solid interface version: 350 Hz


Type Liquid/Solid Interfaces (350 Hz) 2AA0 130.00
Power: 19-230 VAC, ±10%, 50-60 Hz, 8 VA or 19-55 VDC, ±10%, 1.5 W
Alarm Output: Relay delay: Approx. 1 second from loss of vibration; Approx.
1 to 2 seconds from resumption of vibration; Relay failsafe: High or low,
Accessories
switch selectable; Relay 8A at 250 VAC, noninductive Catalog
Description Number Price
Material: Enclosure: Epoxy coated aluminum, NEMA 4/Type 4/IP65; Process
connection: 1.5” NPT; Sensor: Stainless steel; Conduit entry: 1/2” NPT Instruction Manual 7ML1998-5FT61 $10.00
Replacement Electronics Module (125Hz) 7ML1830-1KL 180.00
Approvals: FM/CSA Class II, Div. 1, Groups E–G, Class Replacement Electronics Module (350Hz) 7ML1830-1KM 180.00
III; ATEX II 1/2 D (Dust Explosion Proof ); CE 2” NPT Sliding Sleeve 7ML1830-1JN 170.00
CAPACITANCE Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
164 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Capacitance Point Level Detection Sensors


• Very short (4”) insertion length
• Suitable for use with conductive
Ask Yourself...
or nonconductive process media • Do you have to stock more than one point level switch
— one for liquids and one for solids?
• Accurate, repeatable switchpoint
due to advanced tip-sensing • Do you have constant maintenance issues or mechanical
technology repairs on your detection switches?
• Does your process medium change its physical properties
Flow Measurement

• Extremely high chemical resistance


— temperature, moisture content, purity, or concentra-
Instruments

• Level detection independent of


tion?
tank wall or pipe system
• Do your instrument technicians have to readjust setpoints
• Simple setup procedure, verification
or alarm switches?
with built-in LEDs
• Does your current level probe keep you from using more
• Precision 20-turn potentiometer for
of the tank for your process?
adjustable sensitivity
• Two level outputs: Two-wire current If you answered YES to any of these questions, the Pointek
loop detection and solid-state tran- CLS100 could be the answer you’ve been looking for.
Solids Flow and Motion

sistor relay
• Low maintenance costs. No moving parts
• Can be connected directly to most PLCs One Model Does It All
• Intrinsically safe and dust/ The Pointek CLS100 is only 6.6” long, with a 4” insertion length, and a
ignition-proof models 3/4” NPT process connection, so the unit can be installed in very tight
CLS100
spaces, including small batch tanks, silos, and flow pipe line systems.
The CLS100 can be used in a wide range of liquids, solids, slurries (con-
ductive or nonconductive), and interfaces. In installations where there is
The Pointek CLS100 is the first, low-cost, two-wire level detection a high risk of explosion, certified intrinsically safe or dust-ignition-proof
switch that delivers accurate and repeatable operation in liquids, solids, models are available.
slurries, interfaces, and foam. The CLS100 sensor is insensitive to vapor In many applications, one CLS100 unit can replace several level de-
stratification, partial or full vacuum, dust, carbon dioxide, high liquid tection measurement technologies — conventional capacitance and
Rotary and Electric
Actuator Motors

viscosities, and coatings. mechanical devices (paddle switches, floats, tuning forks, and conduc-
Its remarkably small size and high resistance to chemicals, together tivity switches). As alternate technology backups are required for level
with an intrinsically safe design, make the Pointek CLS100 the perfect applications, the CLS100 is the perfect low-cost choice.
choice in a wide range of applications. In short, the Pointek CLS100
simplifies product selection, ordering, installation, maintenance, and Simple to Install and Operate
spare parts stocking. Just mount the Pointek CLS100 on the application,connect the two-wire
Unlike conventional capacitance level switches, the CLS100 functions current loop to the power supply, and adjust the detection level. That’s
independently of a reference electrode. And, because the CLS100’s tech- it! No special tools needed. In most applications, you don’t even have to
nology doesn’t require a metallic tank wall as the second con­ductor, it shut down the process to install and commission the CLS100.
works in nonmetallic tanks as well as metal ones. The 20-turn potentiometer and status LEDs make tuning easy.You can
The CLS100 comes standard with two separate level outputs, a two- even adjust the sensor in air, to detect almost any product.
Combustion Safety

wire current loop output (4/20 or 20/4 mA), and a solid-state transistor. Because it has no moving parts to wear or replace,the one-piece CLS100
and Efficiency

It can connect directly to most PLCs, so you won’t need to mess with requires very little maintenance to stay in operation.And,since one model
external switch amplifiers or interfaces. works in several applications, you can reduce your spares inventory, and
reduce the time it takes to train instrument technicians on the care and
Tip-Sensitive Technology maintenance of each application’s sensor.
An oscillator with a maximum measurement frequency of about 5.5 With its 3/4” NPT process connection, the CLS100
MHz is integrated in the CLS100 probe section. As soon as the fre­quency can easily be retrofitted to your current process. It
threshold is passed, the switchpoint of the unit is triggered. If you choose, can be used to replace almost any existing DC- or
you can set the trip point to activate an output at the slightest change DC-loop-powered level switch, and you won’t have
in sensor capacitance. Because only the probe’s tip is sensitive to signal to run new cable to make it work!
change, the CLS100 achieves a very accurate and repeatable switchpoint.
and Communications
Wireless Instruments

Tank walls, varying product quality, vapor, or dust have a negligible effect ABS Enclosure with 1/2” NPT Conduit
on the unit’s reliability.
Connection — Only $32!
Chemical and Vibration Resistant Looking for Type 4, NEMA 4X, IP65 enclosure protec-
The CLS100 electrodes and oscillator are fully integrated into the active tion? Add an ABS enclosure to your CLS100.
detection part of the chemically resistant PVDF/Kynar probe. This fully With this option,you can attach electrical conduit to
potted design ensures operating reliability in a vibrating environment (to the CLS100 and wire power into the 5-point terminal
4g), like an agitating tank. The CLS100 can be used in applications where block inside an impact-resistant ABS housing. It has
temperatures reach up to 257° F and in environments with a maximum a 1/2” NPT conduit connection, and a transparent lid
pressure resistance of 365 PSI (25 bar). for viewing the LED.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CAPACITANCE

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
POINT LEVEL 165

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Ordering Instructions
Not sure which level technology is Select one option from each table section below. A completed catalog
right for you? Take a look at our level number looks like this: 7ML5501 - _ _ _ _ _
technology selector on page 183.
Please submit orders to: Siemens,
Find your application and Model Selection Guide c/o Lesman Instrument Company
media conditions, and let our Catalog Price

Flow Measurement
reference guide you to the right Description Number Each
instrumentation for your process. Capacitance Point Level Detection Sensor,

Instruments
3/4” NPT Thread 7ML5501 - $163.00
General Purpose 0AA _ _ 0.00
Approvals Dust/Ignition-Proof 0AB _ _ 20.00
Specifications Intrinsically Safe 0AC _ _ 75.00
Models: Standard, dust/ignition-proof, Standard Integrated Cable _ _ _ 10 0.00
intrinsically safe Versions ABS Enclosure Version _ _ _ 30 32.00
Modes of Operation: High/low Options Integrated Cable, Kynar Probe Body _ _ _ 50 60.00
ABS Enclosure, Kynar Probe Body _ _ _ 60 86.00
Switchpoint Repeatability: 0.08”
Accessories
Operating Frequency: 5.5 MHz

Solids Flow and Motion


Sensguard, 3/4” NPT (PPS) 7ML1830-1DL 50.00
Dielectric Constant: 1.5 min. Stainless Steel Tag (Single Text Line) PBD-45000786 35.00
Temperature Range: -40° to 257° F English Instruction Manual 7ML1998-5QJ81 15.00
Pressure (Vessel) Range: 0 absolute to 2500 CLS Flange, 3/4” Thread for Mounting
kPa (25 bar or 365 PSI) gauge any 3/4” NPT Pointek CLS Level Switch 7ML1500-0_ _0 0.00
Adjustment Potentiometer: 20-turn Pressure Rating (ANSI B16.5)
150 Lbs. (_ A) 300 Lbs. (_ B) 600 Lbs. (_ C)
Current Loop Output: Measurement:
4/20 mA or 20/4 mA loop supplied; Current Flanged 1” (A _) $160.00 $195.00 $205.00
Reversible: By polarity change power sup- Process 1.5” (B _) 195.00 225.00 245.00
Connection 2” (C _) 230.00 260.00 300.00
ply; Load: 600Ω max. @ 24 VDC
Size 3” (D _) 275.00 335.00 360.00
Solid-State Switch: Output: Galvani­cally 4” (E _) 330.00 425.00 505.00
isolated, 100 mA max. load current; Switch
voltage: 28 VAC/40 VDC max.

Rotary and Electric


Actuator Motors
Integrated Enclosure: Housing (Electron­ CLS100 Through the “Looking Glass”
ics)/Connection: AISI 316L stainless steel;
Ingress Protection: Type 4X/NEMA 4X/IP65;
Connection: 4 conductor,22 AWG,shielded,
3.3 ft. black polyester cable
Signal Indicators: LEDs for adjustment
control, output status, and power
Power Supply: Standard/Dust/Ignition-Proof
Models: 10-33 VDC; Intrinsically Safe Models: 10-30 VDC
Sensor Probe: PVDF Kynar®, 4” insertion length, 3/4” NPT or 1” BSPT process
connection

Combustion Safety
Approvals: Standard/Dust/Ignition-Proof Models: CE/KEMA/FM.CSA approvals

and Efficiency
(Class II, III, Div. 1, Groups E, F, G); Intrinsically Safe Models: CE/CENELEC/FM.
CSA approvals (Class I, Div. 1, Groups A-D) CLS100 has been field-tested in many applications. It’s sensitive enough to
measure levels accurately through tank windows and site glasses made
SensGuard Chemical-Resistant Probe Cover of plastic, glass, or fiberglass. It works with a heavy material buildup on
Specifications the sensor (like chocolate or dust), and even in sludge interfaces. Want a
Pressure Range: Full vacuum to 25 bar (FV to 365 PSI) demo? Call us!
Temperature Range: -40º to 125º C (-40º to 257º F)
Construction: Polyphenylene Sulfide, fiberglass filled
Output/Wiring
Process Connections: External: 3/4” NPT and 1” BSPT; In- Solid-State Switch
and Communications
Wireless Instruments

ternal: 3/4” NPT White Standard Version: 250 VAC/300


Insert Length: 2.75” VDC, 100 mA max.
White Intrinsically Safe Version:
Flexural Strength: 315 lbs. 30 VAC/DC max.
Vsupply/mA Loop
Red + Vsupply: Standard: 10-33 VDC,
Intrinsically Safe: 10-30 VDC
Black – mA Loop: Presence=20 mA,
Absence=4 mA
Reverse polarity to invert output
CAPACITANCE Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
166 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Pointek CLS200: Capacitance Point Level Detection Sensors


Models
Choose from several configurations, including rigid, sanitary and cable
sensors. While the base unit remains constant, each model can have a
different selection of process connections, extensions, and approvals.
Both standard and extended length units are designed to operate in
CLS200 clean-in-place (CIP) applications in the food industry.
Flow Measurement

Standard Models: Suitable for use in virtually any point level detection
Instruments

application.With a minimum insertion length of just 4 inches compared


with 14 inches on competitive products, the standard model can be
easily installed in small diameter pipes. In tank applications, content
capacity can be maximized.
Sanitary Models: Meet industry requirements for temperatures exceed-
ing 212° F. The process connection is a sanitary standard tri-clamp.
Wetted parts of 316L stainless steel and PVDF (Kynar®) are 3A compli-
ant and food-grade safe.
Extended Models: Available in both cable and rigid versions. When it is
Solids Flow and Motion

Pointek CLS capacitance point level detection devices: not possible to penetrate the tank wall near the bottom, Pointek CLS
cable versions provide excellent application flexibility through the
• Work accurately without a reference electrode. use of cable extension, protected by a PVDF jacket.
• Detect a single, high, or low level for liquids, solids, slurries, or Effective in both liquids and solids, these versatile units can also be
foam (any material with a dielectric constant >1.5). used for level detection and for interface detection (e.g. oil/water) in
• Work in a vessel of any shape, constructed of conductive or large storage tanks. Cable can be supplied at lengths up to 115 feet to
nonconductive material. meet specific application requirements.
• Operate in temperatures up to 257° F. Rigid versions have short or extended rod lengths up to 18 feet. An
adjustable sliding process mount is available.
• Accept voltage from 12 to 250 VAC/DC, without jumpers.
Options
How is our capacitance offering different?
Thermal Isolator (Thermopart): In applications where the ambient
• Compact design and 3.9” insertion length, so you can use
Rotary and Electric

temperature of the transmitter can exceed 185° F due to hot processes.


Actuator Motors

more of your tank for product. The isolator extension raises the enclosure approximately 4” above
• Adjustable insertion lengths: Slide coupling lets you put the process fitting.
more probe into the process. Process Connections: Process connection sizes range from 3/4” to 1.5
NPT and 1” to 3” sanitary flange.
• Mounting options: 3/4”, 1”, 1.5” NPT, 3A sanitary, and flanges.
Adjustable Sliding Process Mount: For applications where the exact
• Electronics tested to 4G vibration levels in three dimensions. level sensing point is in doubt, a sliding process sealing gland is avail-
• Flame-, explosion-, and dust/ignition-proof approvals. able to provide exact adjustment of the sensor’s position.

Take A Look Inside! See what makes Pointek different.


Combustion Safety

NEMA 4/IP65 Aluminum Enclosure No Relay Chatter!


and Efficiency

The cast aluminum enclosure is Epoxy coated An adjustable output delay prevents chatter
to provide additional chemical resistance. RE- when material is at the critical detection level.
move the lid to gain access to wiring, dip switch It is adjusted by a single potentiometer and
settings, and LED functions. applied to both the SPDT relay and transistor
outputs.
Alarm/Control Functions and Failsafe
Operation It can also be applied when entering or leaving
alarm. The delay can be tem­porarily disabled to
The SPDT relay provides normally open and confirm output operation, without readjusting
normally closed contacts.You can use the failsafe the delay setting.
relay operation for alarm purposes to alarm
and Communications

LED Indicators
Wireless Instruments

on material detection or instrument power


interruption. The Power On, Sensor Status, and Output
The solid-state relay connection (300 VDC or Material Sensitivity Adjustment Status LED indicators provide a simple way to
250 VAC at 100 mA max.) is polarity insen­sitive Reduces Spare Parts verify performance during installation.
for simplified wiring, and galvan­ically isolated When you’re detecting a sticky conductive Power On confirms that power is supplied to
for circuit protection. material, you can easily adjust the material level the unit. Sensor Status indicates that material
You can add a relay across the power source detection switchpoint. For maximum flexibility, has been detected. Output Status shows the
to generate a two-wire output based on the both a range selection switch and potentiom- change in output state.
drawn power supply current. eter are provided.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CAPACITANCE

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
POINT LEVEL 167

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Common Specifications Ordering Instructions
Supply Voltage: 12 to 260 VAC/DC, any polarity, galvanically isolated Select one option from each table section below. A complete catalog
Power Consumption: 2VA/2 Watts number looks like this: 7ML5502 - _ _ _ _ _ - _ _ _ _ - _ _ _ _ . _
Signal Indicators: 3 LEDs provide adjustment, output status, and power Please submit orders to: Siemens,
Adjustment: Potentiometers: 2, for adjustment of time delay and sensitivity; Model Selection Guide c/o Lesman Instrument Company
Switches: 1 SPST dip switch for time delay select. Failsafe high/low, and time Catalog Price
delay test/adjust, high low sensitivity Description Number Each

Flow Measurement
Temperature Range: -40° to 185°F operation and storage CLS200 Capacitance Point Level Detection Sensor 7ML5502 - $305.00

Instruments
Materials: Process Connection: 316L Stainless Steel; Probe: PPS (Ryton); En- Standard Compact, 3.9” Insertion Length (Note 1) 0X _ _ _ - 0.00
closure: Epoxy Coated Aluminum (NEMA 4X, 7/9, IP65) Extended Rod, 10” Insertion Length (Note 1) 1A _ _ _ - 40.00
Extended Rod, 14” Insertion Length 1B _ _ _ - 90.00
Switch Point Repeatability: 0.08”; Hysteresis: 0.08” Extended Rod, 20” Insertion Length 1C _ _ _ - 100.00
Dielectric Constant: 1.5 minimum Extended Rod, 30” Insertion Length 1D _ _ _ - 135.00
Extended Rod, 40” Insertion Length 1E _ _ _ - 165.00
Operating Frequency: 5 MHz maximum
Extended Cable, Length 118” Insertion Length (Note 1) 2A _ _ _ - 50.00
Cable Entry: 1/2” NPT; Cable Gland: PG 13.5 (available) Extended Cable, Length 236” Insertion Length (Note 1) 2B _ _ _ - 80.00
Sanitary Compact, 3.9” Insertion Length (Note 1) 3A _ _ _ - 150.00
Output Functions
Threaded, 3/4” NPT _ _ A _ _ - 0.00
Relay Contact: Form C SPDT, NC or NO contact selectable

Solids Flow and Motion


Threaded, 1” NPT _ _ B _ _ - 20.00
Contact Load: 10 mA/50 VDC min., 50A/30 VDC max.; 8A/250 VAC max. Process Threaded, 1.5” NPT _ _ C _ _ - 45.00
Connection Threaded, 1.25” NPT _ _ K _ _ - 30.00
Switching Capacity: 2000VA/150 Watt max.
Sanitary, 1” Flange _ _ R _ _ - 0.00
Solid-State Switch: Galvanically isolated, with sensor failure detection Sanitary, 1.5” Flange _ _ S _ _ - 10.00
Safety: Non-polarity sensitive (no wiring errors) Sanitary, 2” Flange _ _ T _ _ - 20.00
Sanitary, 2.5” Flange _ _ V _ _ - 30.00
Load: 2 Watt max. Load Current: 100 mA max. Sanitary, 3” Flange _ _ W _ _ - 40.00
Switch Voltage: 250 VAC/300 VDC max.; Voltage Drop: Less than 1 Volt Approvals General Purpose _ _ _10 - 0.00
Time Delay: (On/Off ) 1-60 seconds CSA/FM Dust/Ignition Proof, Zone 10 _ _ _ 20 - 15.00
FM Explosion Proof Cl 1, Div 1, Grps A-D _ _ _ 30 - 30.00
Approvals: General Purpose; Dust/Ignition-Proof: CSA/
FM Class II, Div. 1, Group E, F, G, Class III; Flame-Proof; None 0AA0 0.00
FM Class I, Div. 1, Groups A-D; Explosion-Proof: CSA Thermal Isolator 0BA0 45.00
Class I, Div. 1, Groups A-D PVDF (Kynar) Probe Body 0CA0 35.00

Rotary and Electric


Options Thermal Isolator and PVDF Probe Body 0DA0 80.00

Actuator Motors
Standard Model Extended Rigid Model Sliding Coupling 0EA0 160.00
Thermal Isolator and Sliding Coupling 0FA0 210.00
Process Connections: 3/4” NPT Process Connections: 3/4” NPT Sliding Coupling, PVDF Probe Body 0GA0 250.00
Maximum Length: 4” Maximum Length: 216” Thermal Isolator, PVDF Probe Body, and
Resistance: 365 PSI maximum Resistance: 365 PSI maximum Sliding Coupling 0HA0 265.00
Pointek CLS Flanges, 3/4” Thread for Mounting
Sanitary Model Extended Cable Model Any 3/4” NPT Pointek CLS Level Switch 7ML1500-0_ _ 0 0.00
Process Connections: 1”, 1.5” or 2” Process Connections: 3/4” NPT Pressure Rating (ANSI B16.5)
Tri-Clamp Maximum Length: 1,378” 150 Lbs. (_ A) 300 Lbs. (_ B) 600 Lbs. (_ C)
Maximum Length: 4” Tensile Strength: 396 Lbs. max Flanged 1” (A _) $160.00 $195.00 $200.00
Process 1.5” (B _) 195.00 225.00 245.00
Resistance: 365 PSI maximum Resistance: 150 PSI maximum

Combustion Safety
Connection 2” (C _) 230.00 260.00 300.00
Size 3” (D _) 275.00 335.00 360.00

and Efficiency
4” (E _) 330.00 425.00 505.00
Use the CLS in More Applications Spare Parts and Accessories
Aluminum Enclosure 7ML1830-1DA $107.00
than Ever Before 1/2” HF Cable Gland (GP, Dust/Ignition-Proof ) 7ML1830-1JA 10.00
With the SensGuard abrasive- and chemical- 1/2” HF Cable Gland (Explosion-Proof ) 7ML1830-1JB 18.00
resistant cover for the CLS standard probe. Thermal Isolator PBD-C21013 54.00
Safety Barrier 7ML1830-1DH 60.00
• NPT threaded process connection sizes Amplifier/Power Supply 7ML1830-1DJ 215.00
• Handles pressure ranges form full vacuum to 365 PSIG, Phoenix 2-Wire Trip Device 7ML1830-1DK 105.00
temperatures from -40° to 257° F 3/4” NPT Ryton SensGuard (PPS) Cover 7ML1830-1DL 50.00
English Instruction Manual 7ML1998-5AR01 10.00
and Communications
Wireless Instruments

CLS200, Standard Compact Model, 3.9”


Notes 1 Available only with Options A to D.
Insertion Length, 3/4” NPT Threaded Due to contractual agreements with our manufacturers, some products are not
Connection, General Purpose Approval available in all areas or markets. Call Lesman for more information.
7ML5502-0XA10-0AA0........................$305.00
CLS200, Standard Compact Model, 3.9” Insertion Length, 3/4”
NPT Threaded Connection, FM Explosion-Proof Class I, Div 1,
Groups A-D Approval
7ML5502-0XA50-0AA0...........................................................................$335.00
CAPACITANCE Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
168 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Pointek CLS300: Capacitance Point Level Detection Sensors


The Technology Behind the Performance
The Pointek CLS300 is based on the patented, field-proven LC500
level measurement technology. It combines active shield technology
with a wide input range, temperature stability, and inverse frequency
operation. The active shield is electrically isolated from an active
measurement section.The active measurement section becomes the
frequency-determining component for the triangular wave oscillator
Flow Measurement

in the transmitter.
Instruments

When the capacitance increases or decreases with the level of


material, the measuring frequency changes inversely.The same signal
is also connected to the active shield portion of the probe, effectively
eliminating the electrical potential difference between the shield and
the measurement section. The probe will not be affected by changes
in vapor concentration, dust, or condensation.
The CLS300 will provide accurate level detection even in highly
conductive materials with build-up on the probe.
Solids Flow and Motion

Thermal
CLS300 isolator
eliminates Fully potted
effect of transmitter
Features process unaffected by
temperature condensation,
• One design fits all, even in harsh and heavy duty environ­ dust, or
ments; suitable for high pressures and high temperatures in vibration
liquids, solids, slurries, and interfaces
• All wetted parts made of stainless steel and PFA, Teflon, or
ceramics for high-chemical resistance
• High-sensitivity probe provides accurate level detection
without the effects of conductive material buildup. Works Explosion and flame-proof
epoxy coated enclosure
Rotary and Electric

equally well in wood chips or tomato sauce!


Actuator Motors

with two inlets


• Patented LC500 active technology for reliable point level de-
tection, unaffected by vapor concentration, product deposits,
dust, and condensation
Butterfly plate significantly improves
• Simple threshold/air calibration for rapid, cost-effective switchpoint repeatability in low
setup with LED verification dielectric materials (εr<4.0)
• Universal galvanically isolated power supply and one univer-
sal transmitter provide low cost of ownership and minimal
Dimensions
requirements for stocking spare parts
• Multiple switch outputs provide relay, solid state (transistor),
Combustion Safety

or two-wire point detection with one design, including time


and Efficiency

delays for on/off

The Pointek CLS300 offers accurate, reliable level detection even in


harsh, heavy duty industrial applications with high pressures and high
temperatures.
It’s effective in liquids,solids,slurries,interfaces,and applications involv-
ing viscous (conductive and nonconductive) materials. The fully potted
transmitter is unaffected by condensation, dust, or vibration.
All metal parts are made of stainless steel, with a PFA Teflon shield sec-
and Communications

tion for high chemical resistance. For higher temperature applications,


Wireless Instruments

ceramics can be supplied. Materials with low or high dielectric properties High-
are accurately detected, and the unique active shield helps in ignoring Standard Temperature
the effects of buildup. Model Model
Its unique modular design provides for a wide range of configurations,
process connections, extensions, and approvals to meet the precise
temperature and pressure requirements of specific applications. The Cap Cable
modular design makes it easy to specify and reduces stocking require- (All Models) Model
ments. A wide range of probe configurations is available, including rod
and cable/rope models.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CAPACITANCE

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
POINT LEVEL 169

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Specifications Ordering Instructions
Approvals: FM (Class I, Div. 1, Groups A-D, Class II/III, Div. 1 Grps Select one option from each table section below. A complete catalog
E-G (Dust/Ignition Proof ), CE, CSA (Class I, Div. 1, Grps A-D, Class number looks like this: 7ML5503 - _ _ _ _ _ - _ _ _ _ . _ - N
II/III, Div. 1, Grps E-G (Dust/Ignition Proof )), NRTL/C, CENELEC
EEx d [ia] IIC, T6..T4 Please submit orders to: Siemens,
Model Selection Guide c/o Lesman Instrument Company
Probe
Catalog Price
Probe Lengths: Rod version: 14” to 40”; Rope/cable version: 20” to 985”

Flow Measurement
Description Number Each
Wetted Parts: AOSO 316L/PFA/Peek; High-temperature version: AISI 316L/ CLS300 Capacitance Point Level Detection Sensor 7ML5510 - $425.00

Instruments
ceramics AI203 (99.7%)
Standard Compact, 14” Insertion Length 0X _ _ _ - 0.00
Tensile Force: 4,188 lbs. max. Extended Rod, 20” Insertion Length 1A _ _ _ - 28.00
Pressure Range: 511 PSIG Extended Rod, 30” Insertion Length 1B _ _ _ - 56.00
Extended Rod, 40” Insertion Length 1C _ _ _ - 72.00
Temperature Range: -40° to 398°F; High-temperature version: -40° to 752°F Extended Cable, 118” Insertion Length 2A _ _ _ - 12.00
Dielectric Constant: 1.5 min. Extended Cable, 236” Insertion Length 2B _ _ _ - 67.00
Enclosure: Epoxy coated, NEMA 4/Type 4/IP65 Extended PFA Cable, 118” Insertion Length (Note 1) 3A _ _ _ - 134.00
Extended PFA Cable, 236” Insertion Length (Note 1) 3B _ _ _ - 263.00
Process Connection: NPT/BSPT/JIS
Threaded, 3/4” NPT (Note 2) _ _ A _ _ - 0.00
Power Supply and Transmitter Process Threaded, 1” NPT (Note 2) _ _ B _ _ - 20.00

Solids Flow and Motion


Connection Threaded, 1.5” NPT _ _ C _ _ - 46.00
Supply Voltage: 12-250 VAC/VDC any polarity galvanically isolated Threaded, 1.25” NPT _ _ K _ _ - 27.00
Power Consumption: 2 VA/2 Watt General Purpose _ _ _ 1 _ - 0.00
Wiring Connections: Max. 0.009”; Temperature range: -40° to 185°F Approvals Dust/Ignition-Proof, Zone 10, CSA, FM _ _ _ 2 _ - 15.00
Signal Indicators: 3 LEDs for adjustment control, output status and power Explosion-Proof, CENELEC _ _ _ 3 _ - 25.00
None _ _ _ _ A - 0.00
Adjustment Potentiometers: 2 PCS, for time delay and sensitivity
Thermal Isolator _ _ _ _ B - 43.00
Adjustment Switches: 5 PST dip switch for time delay select.Failsafe high/low Butterfly Plate (Note 3) _ _ _ _ C - 75.00
and time delay test/adjust, high/low sensitivity Options Thermal Isolator and Butterfly Plate (Note 3) _ _ _ _ D - 118.00
Sensitivity: 1% max. change in actual capacitance High Pressure Version _ _ _ _ E - 125.00
High Pressure Version and Thermal Isolator _ _ _ _ F - 168.00
Temperature Drift: 0.2% max. of actual capacitance value High Pressure Version and Butterfly Plate _ _ _ _ G - 200.00
Measurement Frequency: 600 kHz max. High Pressure Version, Thermal Isolator, and

Rotary and Electric


Butterfly Plate _ _ _ _ H - 243.00
E.S.D. Protection (kV): Protected to 55 kV continuous discharge

Actuator Motors
Pointek CLS Flanges, 3/4” Thread for Mounting
Output Functions Any 3/4” NPT Pointek CLS Level Switch 7ML1500-0_ _0 0.00
Relay Contact (with Signal Failure Detection): Contact: Form C SPDT (se- Pressure Rating (ANSI B16.5)
lectable NC or NO contact); Max. contact load: DC: 5A/30 VDC; AC: 8A/250 150 Lbs. (_ A) 300 Lbs. (_ B) 600 Lbs. (_ C)
VAC (cosn=1); Max. switching capacity: 150 Watt/2000 VA; Min. contact load: Flanged 1” (A _) $160.00 $195.00 $200.00
10 mA/5 VDC; Time delay (on and/or off ): 1-60 seconds Process 1.5” (B _) 195.00 225.00 245.00
Solid-State Switch (with Signal Failure Detection): Output: Galvanically Connection 2” (C _) 230.00 260.00 300.00
isolated; Safety: Non-polarity sensitive transmitter; Max. load: 2 Watt; Max. Size 3” (D _) 275.00 335.00 360.00
switch voltage: 250 VAC/300 VDC; Max. load current: 100 mA; Voltage drop: 4” (E _) 330.00 425.00 505.00
Below 1 Volt typical at 50 mA; Time delay (on and/off ): 1-60 seconds. Spare Parts and Accessories
Two-Wire Switch: With customer-supplied external trip devices Aluminum Enclosure 7ML1830-1DA $107.00

Combustion Safety
1/2” HF Cable Gland (GP, Dust/ Ignition-Proof ) 7ML1830-1JA 10.00

and Efficiency
1/2” HF Cable Gland (Explosion-Proof ) 7ML1830-1JB 18.00
Wiring Diagram CLS300 Driver PBD-C31010 68.00
Safety Barrier 7ML1830-1DH 60.00
Amplifier/Power Supply 7ML1830-1DJ 215.00
Phoenix 2-Wire Trip Device 7ML1830-1DK 105.00
English Instruction Manual 7ML1998-5CK04 10.00

Notes
1 Do not select PFA cable version if process temperature exceeds 392°F.
2 Available with rod versions only.
3 Butterfly plate available for use with cable versions only.
and Communications
Wireless Instruments

See instruction manual for detailed wiring, available for free download
at www.lesman.com
CAPACITANCE Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
170 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Pointek CLS500 Point Level Switch for Extreme Conditions


Features Pointek CLS500 is a 2-wire ca-
pacitance point level switch for
• Wide range of applications in high pressure detecting interface solids, liquids,
CLS500
and temperature, chemically aggressive, and slurries, and viscous materials in
other extreme process environments critical conditions of extreme pressure. It uses a unique, frequency-based
• Viscous, conductive and non-conductiveliq- measurement system and patented Active-Shield technology to deliver
uids, solids, slurries, and interfaces highly accurate, repeatable results. The measurement is unaffected by
Flow Measurement

moisture, vapors, foam, temperature and pressure variations, or material


• Smart transmitter with patented Active Shield build-up around the mounting glands.
Instruments

technology and variable frequency oscillator


The CLS500 combines a sophisticated, easy-to-adjust transmitter
• Integrated local display for commis- (MSP-2002-1) with a measurement electrode and process seal designed
sioning and service or remote adjust- to accommodate numerous configurations. The advanced electronics
able programming and control via Hart® and integrated local display provide for one-point calibration without
interrupting the process, and the probe shield design eliminates the
• Analog (2-wire) 4 to 20 mA output
need for frequent recalibration.
• 2-state functionality (4 to 20 mA/20 or 4 mA) Pointek CLS500 can be used as a pump controller, by connecting the
• Adjustable hysteresis on/off for solid-state output 2-state mA output and/or the solid state switch to a relay, and activating
and for current signal; Damping function a pump via an auxiliary power circuit.
Solids Flow and Motion

• Signal current (measurement/detection) according The CLS500 Probe


to NAMUR NE 43 The probe (electrode) comprises a measurement section and an active
• Full range of local/remote diagnostics shield section. This electrode connects to the capacitance detector por-
• Pre-detection of trip point for high safety tion of the two-wire loop powered electronic transmitter.The transmitter
requirements module is mounted in a powder-coated aluminum enclosure which
provides reliable operation in environments with dust, moisture and
• Polarity-insensitive current loop high-frequency interference.
• General purpose, dust ignition proof, explosion proof and • The standard Pointek CLS500 insulated electrode is designed for
intrinsically safe approved models use in both conducting and non-conducting liquid applications
• Most electrodes consist of an active shield portion and a measure-
ment portion that combine to form the complete electrode. (Not
Rotary and Electric

the case for electrodes with ceramic/enamel insulation.)


Actuator Motors

Standard S-Series (Threaded) Standard S-Series (Flange) • The sum of the active shield length and the measurement length is
the total insertion length
• The active shield design provides continuous immunity from
changes in conditions at the top of the vessel where levels of va-
pors, dust, and condensation may be constantly changing
• The design of the active shield isolates the starting capacitance due
to temperature and pressure fluctuations that could cause small
changes in the seal geometry
• The end seal is formed as an integral part of the electrode insula-
tion, giving smooth and uniform characteristics (tested to 55 kV)
Combustion Safety

• Standard single cone seal


and Efficiency

Table of Standard Combinations CLS500 Probe Version


Series S Series HT
Threaded Standard Standard
Flange Standard Standard
Process Stainless steel AISI 316L Standard Standard
Connection Duplex steel Standard
and Communications

Material Hastelloy* B2 or C22 Standard


Wireless Instruments

Monel 400 Standard


Probe P.F.A. Standard
Installations Enamel Standard Standard
Rod Maximum rod length
Length 1000mm/39” 1000mm/39”
Process Maximum pressure (Bar/PSI)** 200/2900 525/7665
Conditions Maximum temperature*** 392°F/200°C 400°F/752°C
* Flange is AISI-316L stainless steel with a 5 mm welded Hastelloy plate
** Depends on temp. range *** Depends on pressure range
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CAPACITANCE

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
POINT LEVEL 171

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Specifications
User Interface ground lug
Measurement Range: 0 to 330 pF
instrument protective label
Span: Minimum 1 pF system
Measurement Frequency: 420 kHz ground
solid state switch relay
Accuracy: Deviation <0.1% of actual measurement value measuring signal (any polarity)
Non Linearity and Reproducibility: 0.1% full scale and actual measure- (mini-coaxial
cable)

Flow Measurement
ment respectively
Temperature Stability: Greater of 0.15 pF (0 pF) or <0.25% (typical <0.1%)

Instruments
actual measurement value over full temperature range ground connection
point for instru- 4-20 mA current
Process Connection: NPT thread; ANSI, DIN flat-faced flanges ment system loop connection
(any polarity)
Process Material: AISI 316 L standard; C 22.8 N, Monel 400, Hastelloy C22,
Duplex optional
Safety: Current signalling according to NAMUR NE 43; 3.6 or 22 mA, probe Enclosure: Aluminum, epoxy coated Type 4X/NEMA 4X/IP65; 2 x 1/2” NPT
input ESD protected to 55 kV, inputs/outputs fully galvanically isolated, cable entry
polarity-insensitive current loop, fully potted, integrated safety barrier Temperature Rating: -328° to 392°F (-200° to 200°C), up to 752°F (400°C)
Diagnostics: Includes fault alarm when primary variable (PV) out of limits, optional

Solids Flow and Motion


system failure in measurement circuit, deviation between A/D and D/A Supply Voltage: 12 to 33 VDC (30 VDC for IS model)
converter, checksum, watch dog and self-checking facility probe
Loop Current: 3.6 to 22 mA / 22 to 3.6 mA (2-wire current loop)
Probe Length: Rod version: up to 1000 mm (216”) with 16 or 24 mm diam-
Environmental: Location: indoor/outdoor; Altitude: 2000 m maximum;
eter probe
Ambient Temperature: -40° to 185°F (-40° to 85°C) standard, -40° to 158°F
Diameter: 16 mm (0.63”) or 24 mm (0.95”) rod (-40° to 70°C) for T6, -40° to 185°F (-40° to 85°C) for T5 to T1 ATEX explo-
Probe Installation: PFA, Enamel sion proof; Relative humidity: suitable to outdoor; Installation category: II;
Pollution degree: 4
Function Rotary Switch: Positions 0 to 9, A to F
Approvals: CE; FM/CSA: Class I, II & III, Div. 1 Groups
Remote Communication: HART® Foundation A-D (Intrinsically Safe), Class I, Div. 2, Class II, Div. 2,
Pressure Rating: FV to 50 bar (725 PSI), up to 525 bar (7665 PSI) optional Class III, Div. 1 & 2 (Hazardous Locations); FM: Class
I, II & III, Div. 1 Groups A-D (Explosion Proof ); 3A Sanitary

Rotary and Electric


Model Selection Guide

Actuator Motors
Ordering Instructions
Make one selection from each table below. A complete catalog number Catalog
looks like this: 7ML5601 - _ _ _ _ _-_ _ AO_Z Description Number Price
Pointek CLS 500, S-series, welded flange
Model Selection Guide 2-wire capacitance point level detection instru-
Catalog ment, PFA probe insulation, 316L SS connection 7ML5602 - $465.00
Description Number Price Electronic None 0_ _ _ _ - 0.00
Pointek CLS 500, S-series, threaded Transmitter MSP2002-1 (330 pF) 1____- 760.00
2-Wire capacitance point level detection instru- Connection 2” ANSI, 150 lb _ AA1 _ - 0.00
ment, PFA probe insulation, 316L SS connection 7ML5601- $465.00 Type and 2” ANSI, 300 lb _AB1 _ - 13.00
Electronic None 0_ _ _ _ - 0.00 Rating 3” ANSI, 150 lb _ BA1 _ - 30.00
3” ANSI, 300 lb _ BB1 _ - 70.00

Combustion Safety
Transmitter MSP2002-1 (330 pF) 1____- 760.00
4” ANSI, 150 lb _CA1 _ - 60.00

and Efficiency
Process 3/4” Threaded NPT _ AA1 _ - 0.00 4” ANSI, 300 lb _CB1 _ - 145.00
Connection 1” Threaded NPT _ BA1 _ - 0.00 6” ANSI, 150 lb _DA1 _ - 135.00
Size 1 1/4” Threaded NPT _ CA1 _ - 0.00 6” ANSI, 300 lb _DB1 _ - 365.00
1 1/2” Threaded NPT _ DA1 _ - 0.00 Note: For other flange sizes or pressure ratings, please call for availability and pricing.
2” Threaded NPT _EA1 _ - 0.00
Approvals General Purpose _ _ _ _1 - 0.00
Approvals General Purpose _ _ _ _1- 0.00 NI/DIP- FM/CSA (Class I, Div. 2,
NI/DIP- FM/CSA (Class I, Div. 2, Group A-D; Class II, Div. 1,
Grps A-D; Class II, Div. 1, Grps E-G) _ _ _ _2 - 60.00 Group E-G) _ _ _ _2 - 60.00
IS- FM/CSA (Class I, Div. 1, Grps A-D) _ _ _ _3- 120.00 IS- FM/CSA (Class I, Div. 1, Grps A-D) _ _ _ _3 - 120.00
XP- FM/CSA (Class I, Div. 1, Grps A-D) _ _ _ _5- 165.00 XP- FM/CSA (Class I, Div. 1, Grps A-D) _ _ _ _5 - 165.00
Probe/Electrode Diameter Probe/Electrode Diameter
and Communications

16mm Rigid Rod, 1000 mm max length 1_ _ _ - _ 0.00


Wireless Instruments

16mm Rigid Rod, 1000 mm Max Length 1_ _ _- _ 0.00


Rigid Thermal Isolator _ AA0-Z 90.00 Rigid thermal isolator _ AA0 - Z 0.00
Options Total Insertion Length Y01 _ _ _ _ 2.50/25mm Options Total Insertion Length Y01 _ _ _ _ 2.50/25mm
Active Shield Length (50mm Min.) Y02 _ _ _ _ 0.00 Active Shield Length (50mm Min.) Y02 _ _ _ _ 0.00
Stainless Steel Tag (Max. 20 Char) Y15 (text) 35.00 Stainless Steel Tag (Max. 20 Char) Y15 (text) 35.00
Test certificate B (Meets DIN 50049 §3.1 Test certificate B (Meets DIN 50049 §3.1
and EN 10204) C12 100.00 and EN 10204) C12 100.00
Instruction Manual 7ML1998-5GG01 16.00 Instruction Manual 7ML1998-5GG01 16.00

Call for pricing on single piece flange and high-temp configurations.


ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
172 POINT LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Pointek ULS200: Ultrasonic Point Level Detection Sensor


The perfect point level backup device for
ULS200 your capacitance applications.

Features ULS settings. No modification or replacement units are required. (Stan­


dardizing on the Pointek ULS for all your applications could bring you
• Noncontacting point level detection on significant savings.)
bulk solids (0.8 to 9.8 ft.), liquids and slurries
Flow Measurement

The noncontacting Pointek ULS200 is virtually immune to the problems


(0.8 to 16.4 ft.) inherent to most contacting level detection devices and is unaffected by
Instruments

• Type 6, NEMA 6/IP67 polycarbonate or the presence of suspended solids in a liquid application.

Ideal forrol!
aluminum enclosure The ULS200 system combines the sensor and the electronics in a
t
sump con
• Built-in temperature compensation single, lightweight body. The ultrasonic sensor continuously emits sonic
pulses that are reflected as echoes from the target surface. By measuring
• Two-button setup, simple cable-entry the time delay between transmitted and reflected pulses, the levels at
wiring, and a self-cleaning sensor preset points are detected.
• AC or DC power supply
Installation Couldn’t be Simpler
• Sanitary version available, with an industry
Just mount the compact Pointek ULS200 unit on the top of the vessel
standard flange
Solids Flow and Motion

with a standard 2” fitting, connect it to the appropriate AC or DC power


supply, set detection levels using the two built-in programming keys.
That’s it! No need to shut down the process or fill/empty the vessel. The
Siemens’ Pointek ULS200 delivers superior performance while sanitary model is easy to remove and clean — a key requirement for
dramatically reducing your maintenance, downtime, and equipment food and beverage processes.
replacement costs.
Wide Application Versatility
Unmatched Performance To meet the need for configurations that are effective in standard
This low-cost, ultrasonic switch is capable of noncontacting detection processes as well as class/zone approved applications, the Pointek
of two distinct levels on liquids, slurries and solids. It works effectively ULS200 enclosure can be ordered in polycarbonate or aluminum with
on bulk solids applications up to 9.8 ft. and on liquids and slurries up to a chemically-resistant Tefzel or Kynar-Flex sensor. This extends the unit’s
16.4 ft, without ever touching the process. Unlike contacting point level usage to chemical, petrochemical and water, and wastewater industries,
devices, there is no material buildup or plugging on the sensor, eliminat- where more rigorous approval levels are required.
Rotary and Electric

ing many problems associated with invasive mechanical devices such


Actuator Motors

When compared to other point level detection products, the Pointek


as bubblers and floats. ULS200, with its unique and powerful features, delivers a cost-effective
Its rugged integrated design (which combines both the sensor and solution at an extremely low cost of ownership.
the electronics in one durable package), and absence of moving parts
provide virtually maintenance-free operation. The Sonic Intelligence® Advantage
One unit can provide both high and low level detection which results To ensure consistently reliable data, echoes are processed by Siemens’
in a reduced initial investment as well as a low ongoing cost of owner- proven Sonic Intelligence® software.Using advanced filtering techniques,
ship.The two adjustable switch outputs are programmable for high-high, this software differentiates between the real and false echoes reflected
high-low, and low-low level alarms. from obstructions and acoustical or electrical noise. It also captures weak
“true” echoes in difficult environments.
The use of ultrasonic technology for point level detection means that
there is no need to specify the length of the wetted part on installation. The Pointek ULS ultrasonic sensor continuously emits sonic pulses
Combustion Safety

If your application specification changes, simply adjust the Pointek that are reflected from the target surface. By measuring the time delay
and Efficiency

between transmitted and reflected pulses,levels are constantly monitored.


To optimize accuracy,the Pointek ULS output is auto­matically temperature
compensated before conversion to distance.
In Case of Emergency... For Clean-In-Place
Application Flexibility
You can use your Pointek ULS200 as a high-level
emergency shutoff switch! A three-step regimen is used in this CIP
application to clean all pipework and ves-
It’s a good engineering practice to have a backup high- sels used in making ice cream products.
level switch that uses a different technology than your The ULS200 is mounted on stainless
continuous level devices. steel tanks that contain various water and
and Communications
Wireless Instruments

Look at all the ULS200 offers... chemical com­binations. The unit is then
set to de­tect two different levels.
• Two independent settings that allow for high- and low-
level switch points from a single unit One output controls an inlet valve. The
second controls a pump.
• Noncontacting, self-cleaning sensor, made of Tefzel®
The ULS unit detects both high and
or Kynar-Flex® low levels within a tolerance set by the
• Polycarbonate or Epoxy enclosure available hysteresis, and can be reprogrammed
• Simple, push-button setup easily, at any time.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
POINT LEVEL 173

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Note: The ultrasonic Pointek ULS200 is intended Not sure which level technology is
to be a primary measure­ment and control device. right for you? Take a look at our level
For overfill or level safe protection, Siemens ad- technology selector on page 183.
vises using Pointek contacting technology, like the Find your application and
CLS200 on pages 164 to 165 of this catalog. media conditions, and let our

Flow Measurement
reference guide you to the right
instrumentation for your process.

Instruments
Specifications Dimensions
Operations
Ordering Instructions
Detection Range: Liquids: 0.8 to 16.4 Select one option from each table following. A complete catalog number
ft. Solids: 0.8 to 9.8 ft. looks like this: 7ML1510 - _ _ _ _ _
Operating Modes: High, low, high-
high, high-low, low-low level indi- Please submit orders to: Siemens,
c/o Lesman Instrument Company
cation Model Selection Guide
Repeatability: 0.25% of full range Catalog

Solids Flow and Motion


Resolution: 0.1” Description Number Price
Echo Processing: Patented Sonic ULS200: Ultrasonic Point Level Detection Sensor 7ML1510 - $620.00
Intelligence® software 24 VDC, Relay Output 1 _ _ _ _ 0.00
Power 24 VDC, Transistor Output 2 _ _ _ _ 0.00
Memory: Nonvolatile EEPROM
100 to 230 VAC, Relay Output 3 _ _ _ _ 90.00
Operating Pressure: 30 PSI (200 Approvals CE, FM (Note 1) _ G _ _ _ 45.00
kPa or 2 bar) CE, CSA, NRTL/C, FM _ H _ _ _ 0.00
Sensor Beam Angle: 10° at 3db Process 2” NPT ETFE _ _ A _ _ 30.00
boundary Connection 2” NPT PVDF Copolymer _ _ E _ _ 0.00
Ambient/Process Temperature: Housing/ Polycarbonate, 1/2” NPT _ _ _02 0.00
-40° to 140°F. Metal mounting: -5° Cable Entry Aluminum, 1/2” NPT _ _ _04 110.00
to 140°F. FMS200 Universal Box Bracket 7ML1830-1BK 95.00
Parts and Universal Adaptor, 2” NPT 7ML1830-1BT 110.00

Rotary and Electric


Outputs

Actuator Motors
Accessories Sanitary, 4” Clamp 7ML1830-1BR 55.00
AC Version: 2 form C (SPDT) contacts, rated 5A at 250 VAC noninductive Polycarbonate Lid PBD-22100329 10.00
DC Version: 2 nonpolarized transistor switches rated 48 VDC, 100 mA max. Aluminum Lid PBD-54001366 25.00
or 2 form C (SPDT) contacts, rated 5A at 48 VDC English Instruction Manual 7ML1998-1AS01 10.00
Note 1: For hazardous applications, available only with aluminum
Display Information housing option 04.
LCD: Displays three 0.35” digits for programming distance between sensor
face and material. Multi-segment graphic for operation status.
ULS200, 100 to 230 VAC, Relay Output,
Programming: 2 keys CE, FM Approvals, 2” NPT Tefzel Process
Installation Connection, 1/2” NPT Aluminum
Housing/Cable Entry
Power Supply: 18 to 30 VDC, 3W max. or 100 to 230 VAC max. 7ML1510-3GA04...................................$895.00

Combustion Safety
Terminal Block Wiring: 14 gauge solid/16 gauge stranded max.

and Efficiency
ULS200, 100 to 230 VAC, Relay Output, CE Approval, 2” NPT
Cable Entry (2 connections): Polycarbonate enclosure: PG 13.5 or 1/2” NPT. PVDF Copolymer Process Connection, 1/2” NPT Aluminum
Aluminum enclosure: 1/2” NPT or PG 13.5 Housing/Cable Entry
Sensor Mounting: Threaded: 2” NPT, 2” BSP or PF2. 7ML1510-3GE04.....................................................................................$865.00

Integrated Enclosure
Electronics: Material: Polycarbonate or Epoxy coated aluminum with gasket.
Ingress protection: Type6/NEMA 6/IP67. Sensor: ETFE or PVDF
Environmental: Location: Indoor/outdoor;Altitude: 6562
ft. max.; Install­ation category: II; Pollution degree: 4 Need more information?
Learn all you need to
and Communications

Approvals: CE, 3A, CSA, FM. For hazardous applica-


Wireless Instruments

tions: CSA, FM Class I, Div 1, Zone 1, Class III, CENELEC know about Siemens level
instrumentation by visiting
www.lesman.com.

Due to contractual agreements with our manufacturers, some


NOTE: products are not available in all areas or markets. Call Lesman
Inside Sales for more information.
LEVEL BY Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
174 WEIGHT Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Load Cells for Level by Weight


Features
• Easy mounting
• Only 25/35 mm installation height
• Hermetically welded seal IP68 equilvalent to NEMA 6
• Stainless steel construction
Flow Measurement

• Direct 4 to 20 mA output (LA)


Instruments

• CENELEC Ex-version available (LE)


• Level control for liquid and bulk materials

a load cell?
This is the perfect solution to all your level control requirements: Ready to order
help
Sartorius’ revolutionary PanCake® technology for level-by-weight ap-
Call Lesman fotr model
plications. This system is extremely durable for the utmost precision gh
picking the ri t for your
and mounting kiion.
in most applications. It works independent of material properties and
the surrounding environment. Retrofitting is fast and easy. PanCake
technology is tried and tested in many installations, and is available at
applicat
Solids Flow and Motion

an affordable price.
Conventional level control instrumentation can lead to errors of 5% and
Specifications
more. In extreme cases this could result in interruption of the associated Load Cell Construction: Hermetically sealed,welded stainless steel construc-
process. New PanCake level-by-weight technology gives extremely ac- tion, filled with Polyurethane
curate readings better than 1% in “real-life” applications over a complete Material: 500kg; 10t: 1.4021 (DIN), 420 S 37 (B.S.); 16t: 1.4542 (DIN), S 604/S
range of capacities up to more than 35,000 pounds. 622 (B.S.), 17 to 4 pH (Int.)
Exceptionally price competitive, the PanCake system offers not only Protection: IP68, IEC 529, equilvalent to NEMA 6. The load cell can be sub-
great technical advantages, it also offers exceptional value for the merged in water to a depth of 1.5m for 10,000 hours.
money. Compared to ultrasonic or radar systems, savings of up to 50% Cable: Robust, flexible, screened; Sheath: Thermopl, Elastomer; Color: gray
are possible. (LE: blue, LA/LAC: green); Diameter: 5mm, wires 4 x 0.35 mm2; Length: 5m;
The extremely reliable, tough and durable design of sensors and the Bending radius: ≤ 50mm
use of high quality materials lead to unequaled reliability, even under Certificate of Conformity: EEx ia IIC T6 (PTB Nr. Ex-00.E.2040, II 2G EEx ia II
Rotary and Electric

harsh industrial conditions.Maintenance or recalibration is rarely needed, T6 (PBTB 00 ATEX 2039)


Actuator Motors

except in case of mechanical changes to the tank.


The high quality sensor maintains calibration for years, without drift Technical Data L LA/LAC LE
or creep. The stainless steel housing is hermetically sealed by welding Accuracy Class 0.5%
and complies to the highest rating (IP68) for 10,000 hours at 1.5m (5’), Minimum Dead Load 0%Emax 5%Emax 0%Emax
equivalent to NEMA 6. Safe Overload 150%Emax 100%Emax 150%Emax
PanCake Capabilities Destructive Load 300%Emax
The model LA provides 4 to 20 mA output for direct connection to Rated Output 2.0 16mA 2.0
process instrumentation or PLCs/DCS. Models L and LE featuring mV/V Tolerance on Rated Output < 4
output are connected via Sartorius transmitters and indicators. Usually Tolerance on Zero Signal < 4 4mA <4
only one PanCake is required (three legs). If two are used (four legs) you Repeatability Error <0.1
Combustion Safety


still require only one input channel in your PLC or Process Indicator by Creep During 30 Minutes <0.1
and Efficiency


simply switching the two outputs in parallel. Non-Linearity <0.25 <0.25 <0.25
Hysterisis <0.15
Temperature Effect on Zero <0.15%Cn/10K
Temperature Effect on Output <0.1%Cn/10K <0.1%Cn/10K <0.1%Cn/10K
Input Impedance 645±60Ω 645±60Ω
Watch our website for Output Impedance 635±15Ω 635±15Ω
more information Insulation Impedance >5000x10Ω >5000x10Ω
on Sartorius load cells, Recommended Supply Voltage 4 to 21V 20 to 28V 4 to 24V
scales, and precision
Maximum Supply Voltage 32V 28V 25V
and Communications

batching systems.
Wireless Instruments

Ambient Temperature -10° to 70°C -30° to 55°C -10° to 55°C


(Nominal) (Nominal) (Nominal)
-30° to 95°C -30° to 70°C -30° to 95°C
(Usable) (Usable) (Usable)
Storage Temperature -40° to 95°C -40° to 80°C -40° to 95°C
Permissable Eccentricity 10mm
Vibration Resistance 20g, 100h, 10 to 150 Hz
Air Pressure Effects ≤20g/kPa
Nominal Deflection Up to 2t <0.1/16t <0.2mm
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan LEVEL BY

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
WEIGHT 175

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Precise for All Materials
The new PanCake level-by-
weight technology determines
Easy to Install
Just lift one leg of the vessel
for a little more than an inch,
Why Use a Load Cell for Level?
the actual content of a vessel slide the PanCake into the gap, Easy Start Up... Better Performance... Low Maintenance
directly in kilograms or pounds. setup is ready, in many instances Calibration without weights — Competitors calibration of 50,000lb
With one sensor for all materials, without additional mounting vessel normally takes 4 to 6 hours. There are usually no weights avail-
it provides reliable readings of kits, complicated mechani- able . Sartorius calibration time is less than 20 minutes.
the material measured. There is cal conversion of the vessel,
No shimming or corner adjustments — Sartorius PanCake only takes 5
one sensor for all materials. or changes to the pipework.

Flow Measurement
minutes, by hand rotating the load cell to determine whether or not
Easy to start up. No calibration there is a load. Only a minimal 1% of the load is required.

Instruments
weights required.
No resistors or trim pots in the junction box — Resistors and poten-
tiometers tend to be temperature and moisture sensitive. This can
affect system accuracy.
Matched load cells — All Sartorius load cells are totally matched and
can be replaced without the need for re-calibration.
No influence from the effect of mixers (moving center of gravity)— Due
to matched load cells and unique mounting design
No side load effects due to temperature expansion of the vessel
—Side forces are taken by the mounting kits which have freedom

Solids Flow and Motion


Example 1: Formation of foam Example 1: The vessel is lifted at one for temperature expansion.
and bubbles, phase transition and side only. The resulting inclination
evaporation may affect others, but is small enough not to disturb the Load cells have lighting protection — Special strain gauge design in
not PanCake. readings. combination with our junction box makes it possible.
Stainless steel and hermetically sealed — The load cells can be sub-
merged in water under 5 feet for 10,000 hours.
Special load cell cable for harsh environments — No PVC insulation,
PTFE is used for high chemical resistance and a Kevlar fiber for “Pull
Protection.”
High Ω load cell design — 650 to 1200Ω input resistance for minimizing
the effect of cabling on accuracy and higher signal under intrinsically
safe conditions
NOW limited LIFETIME WARRANTY on most STAR Line load cells

Rotary and Electric


Actuator Motors
Load cells remain within all specifications up to a usable load of 150
to 200% of nomial
Example 2: Material sticking to the Example 2: One leg of the vessel All controls are designed with a built-in test function and can be
wall of a vessel, variable moisture is just shortened by an inch. No “calibrated without weights.”
content and deviations in particle inclination occurs.
size, but PanCake gets it right. We offer a wide range of weighing and batching solutions, from
simple indication to complex batching systems.

Combustion Safety
and Efficiency

Example 3: Material cones from Example 3: The vessel is lifted


filling or discharging, but cannot leg-by-leg, one leg is supported by
comprise readings of PanCake. PanCake. Other legs are leveled out
by adding shimming plates.
and Communications
Wireless Instruments

Sartorius Accuracy Class is calculated using these criteria: Hysteresis, lin-


earity, temperature effects on zero and span, repeatability, and creep.

Such a small These compression load cells are available with several accuracies:
PR6201 (Left): 0.25% to 0.5%; 0.04% to 0.05%; or 0.015%
solution to a PR6211 (Center): 0.04% to 0.05%
PR6241 (Right): 0.04% to 0.05%; 0.015%; or 0.008%
big problem! Looking for a high accuracy load cell? Call Lesman!
LIQUID LEVEL Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
176 TRANSMITTERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Submersible Liquid Level Transmitters


Features Model Selection Guide
• Standard ranges available from stock Pressure Maximum Burst** Catalog Price
Range Pressure* Pressure Number Each
• Rated IP68 for permanent submersion LS-10: 316 SS, Polyurethane, Polyamid wetted parts,
• 4-20 mA two-wire output signal G1/2B pressure connection, 4-20 mA output. Select cable
length below and append to catalog number.
• Vented polyurethane cable withstands
Dimensions 0-100”WC 30 PSI 30 PSI 4262761 $349.00
Flow Measurement

220 pounds of strain 0-150”WC 30 PSI 30 PSI 4262779 349.00


• Custom cable lengths available
Instruments

0-250”WC 60 PSI 60 PSI 4262787 349.00


0-5 PSI 30 PSI 30 PSI 4262809 349.00
WIKA LS-10 submersible liquid level transmitters 0-10 PSI 60 PSI 60 PSI 4262817 349.00
and transducers are engineered for a wide variety 0-15 PSI 70 PSI 70 PSI 4262825 349.00
of industrial and municipal liquid level measure- 0-25 PSI 145 PSI 145 PSI 4262883 349.00
0-30 PSI 145 PSI 145 PSI 4262841 349.00
ment applications. Each transmitter undergoes
0-50 PSI 245 PSI 245 PSI 4262850 349.00
extensive quality control testing and calibration 0-100 PSI 500 PSI 500 PSI 4262868 349.00
to achieve an accuracy ±0.25% full scale.
5’ 4347868 0.00
The printed circuit boards use state-of-the- 10’ 4347876 12.50
art surface mount technology for protection 15’ 4347885 25.00
Solids Flow and Motion

against mechanical shock and vibration. Each is 20’ 4347893 37.50


tempera­ture compensated to assure accuracy 25’ 4347906 50.00
and long term stability when exposed to severe 30’ 4347915 62.50
temp­erature variations. 35’ 4347923 75.00
40’ 4347931 87.50
The LS-10 features a watertight,vented polyure­ 45’ 4347949 100.00
thane cable that can withstand over 220 pounds of Vented Polyurethane 50’ 4347957 112.50
strain.This allows the transmitter to be supported Cable (Append to 55’ 4347966 125.00
without any additional cabling. The LS-10 meets Transmitter Part Number 60’ 4347974 137.50
NEMA 6P and IP 68 requirements for submersion e.g., 4262850/4360903) 65’ 4347982 150.00
up to 300 feet. 70’ 4347990 162.50
75’ 4348006 175.00
e Submersible e.
80’ 4348016 187.50
Intrinsically Saf
el Also Availabl
s
Don ’t 85’ 4348024 200.00
Rotary and Electric

Transmitter Mod to orde r 90’ 4348032 212.50


Actuator Motors

fo rg et
Call for Pricing.
ant 95’ 4360903 225.00
a dessic 100’ 4348040 237.50
dryi ng 110’ 4348058 262.50
cartrid
ge . 120’ 4348066 287.50
LevelGuard™ Anti-Clog Accessories
Attachment for Submersible Stainless Steel LevelGuard™
Desiccant Drying Cartridge
50077091 395.00
9836700 14.00
Liquid Level Transmitters Vent Tube Filter 7193131 10.00
Cable Clamp 2074257 21.00
Features Additional Weight 1524399 65.00
Cable Junction Box 2459686 75.00
• For lift stations, wet wells, and other level applications 1/2” NPTF Cable Conduit Adapter 2289718 25.00
Combustion Safety

• All 316 stainless steel construction for durability Notes


and Efficiency

• 2” diameter diaphragm provides excellent * Maximum pressure, causing no permanent changes in


sensitivity specifications but may lead to adjustable zero/span shifts.
• Birdcage-style enclosure protects diaphragm ** Burst pressure, leading to destruction of transmitter.
from physical damage and turbulence Need a cable longer than 120 feet?
• Added weight prevents unwanted transmitter Call for pricing and availability.
movement

The WIKA LevelGuard attachment is designed for dif-


ficult level sensing applicatoins where sludge, slurry, or turbulence may be present.
and Communications
Wireless Instruments

The large 2” diaphragm provides excellent sensitivity and performance, even when
used to monitor extremely low liquid levels, or when the assembly is buried in a layer
of sludge or slurry. The cable supplied with the WIKA LS-10 submersible transmitter is
designed to withstand more than 200 pounds of strain, so no additional support or
conduit connections are required.

Visit www.lesman.com for more details, and shop online


through our secure web store.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan LIQUID LEVEL

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TRANSMITTERS 177

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Submersible Pressure Transmitter for Liquid Level
Features
• Transmitter for hydrostatic depth measurement
• Piezoresistive flush-mounted sensor
• Stainless steel sensor and enclosure SITRANS P MPS pressure transmitters have a flush-mounted piezoresis-
• 4-20 mA two-wire output tive sensor with stainless steel diaphragm, for measuring liquid levels in
wells, tanks, channels, and dams.

Flow Measurement
• 0.3% accuracy
On one side of the sensor, the diaphragm is exposed to the hydrostatic

Instruments
• Easy installation with junction box or cable hanger pressure, which is proportional to the submersion depth.This pressure is
compared with atmospheric pressure. Pressure compensation is carried
Specifications out using the vent pipe in the connection cable.
Measuring Range Maximum Working Pressure The liquid column’s hydrostatic pressure acts on the diaphragm, and
0–2 m (0–6 ft) H2O 1.4 bar (20.3 psi) 14 m (42 ft) H2O transmits the pressure to the sensor’s piezoresistive bridge.
0–4 m (0–12 ft) H2O 1.4 bar (20.3 psi) 14 m (42 ft) H2O
0–6 m (0–18 ft) H2O 3.0 bar (43.5 psi) 30 m (90 ft) H2O Ordering Instructions
0–10 m (0–30 ft) H2O 3.0 bar (43.5 psi) 30 m (90 ft) H2O Select one option from each table following. A complete catalog number
0–20 m (0–60 ft) H2O 6.0 bar (87.0 psi) 60 m (180 ft) H2O looks like this: 7MF1570 - _ _ _ _ _

Solids Flow and Motion


Zero and Span: Influence of Ambient Temperature: 1–6 m (3–18 ft) H2O:
0.45%/10 K fullscale;≥6 m (18 ft) H2O:0.3%/10 K full scale;Long-Term Stability: Please submit orders to: Siemens,
1–6 m (3–18 ft) H2O: 0,25% full scale; ≥6 m (18 ft) H2O: 0.2% full-scale Model Selection Guide c/o Lesman Instrument Company

Ambient Operating Temperature: 14°–176 °F (-10°–80 °C) Catalog


Description Number Price
Material: Sensor/Casing: Stainless steel, mat. No. 1.4571/316 Ti; Gasket: Viton;
Connecting Cable: PE/HFFR sheath (non-halogen) SITRANS P MPS Submersible Transmitter for Level 7MF1570 - $380.00
0–2m H2O, 10m Cable 1CA01 0.00
Degree of Protection to DIN EN: IP68 0–4m H2O, 10m Cable 1DA01 0.00
Electrical Connection: Cable with 2 conductors with screen and vent pipe, 0–6m H2O, 25m Cable 1EA01 89.00
strength cord (max. 300 N (67.44 lbf ) Range/ 0–10m H2O, 25m Cable 1FA01 89.00
Cable 0–20m H2O, 25m Cable 1GA01 89.00
Power Supply: Terminal voltage on pressure transmitter: 10–36 V DC Length 0–6 Ft H2O, 32 Ft Cable 1KA01 0.00
Explosion Protection: Intrinsic safety “i” TÜV 03 ATEX 2004X; Identification: 0–12 Ft H2O, 32 Ft Cable 1LA01 0.00
0–18 Ft H2O, 82 Ft Cable 1MA01 89.00
Ex II 1 G EEx ia IIC T4

Rotary and Electric


0–30 Ft H2O, 82 Ft Cable 1NA01 89.00

Actuator Motors
Junction Box: For connecting the transmitter cable; Enclosure: Polycarbon- 0–60 Ft H2O, 82 Ft Cable 1PA01 89.00
ate, with vent pipe for atmospheric pressure and screw for cable strength Accessories Plastic Junction Box, IP54 7MF1570-8AA 47.50
cord; Electrical Connection: 2x 3-way (28–18 AWG); Cable Entry: 2x M20x1.5; Carbon Steel Cable Hanger 7MF1570-8AB 11.90
Degree of protection to DIN EN 60529: IP54 Download the SITRANS P MPS operation manual from
Cable Hanger: For mounting the transmitter; Galvanized steel, polyamide www.lesman.com

Loop-Powered Submersible Model Selection Guide


Select (1) sensor, (2) cable, and (3) breather assembly to complete unit.
Level Transmitter Catalog
• Easy, trouble-free installation Description Number Price

Combustion Safety
1.5 PSI Sensor (3.5 Ft H2O) 6012950011 $800.00

and Efficiency
• 2-5/8” Teflon-coated Buna-N diaphragm A1000i Sensor 5 PSI Sensor (11.5 Ft H2O) 6012950012 800.00
• FM/CSA Intrinsically safe, Class I, Div. 1, Sub-Assembly 15 PSI Sensor (34.7 Ft H2O) 6012950013 800.00
Group A-D rated with approved barrier 30 PSI Sensor (69.3 Ft H2O) 6012950014 800.00
20’ cable 6012640002 744.00
• Electronic components are electronically Polyethylene 30’ cable 6012640003 804.00
and physically isolated from sensed media Cable 40’ cable 6012640004 864.00
Assembly 60’ cable 6012640006 984.00
Specifications 80’ cable 6012640008 1104.00
Output: 4-20 mA 100’ cable 6012640010 1234.00
Accuracy: 0.25% full scale, long term stability: 0.2% full scale/year GSCL breather bag assembly kit (required) 6012880001 60.00
Dual breather bags (2) for over 85’ 6012880002 100.00
and Communications
Wireless Instruments

Max Overpressure Range: 1.5 PSI 8X full scale; 5.0 PSI 4X full scale; 15 PSI TCB junction box with breather 6012910002 319.00
& 30 PSI 2X full scale IS2-2 intrinsic safety barrier; 4-20 mA output 6013150006 515.00
Temperature Range: -40° to 185°F (Liquid must remain fluid) B100 9G CL3 stainless steel mounting clamps 6011340001 78.00
Materials: Housing: 316 Cast Stainless Steel, Teflon® coated; Sensing head: Suspension pipe mount (no SS cable/clamps) 6014180001 250.00
Two layer diaphragm with Teflon and Buna-N; Exposed materials: 316 cast 316 SS cable suspension mounting kit: 21’ 6014400020 60.00
stainless steel, Teflon-coated, PVC, synthetic rubber and Urethane; Cable: 316 SS cable suspension mounting kit, 31’ 6014400030 75.00
Heavy-duty Polyethylene, vent tube, shielded 18 AWG conductors 316 SS cable suspension mounting kit, 41’ 6014400040 90.00
316 SS cable suspension mounting kit, 61’ 6014400060 115.00
Atmosphere Ventilation: No-maintenance sealed breather system 316 SS cable suspension mounting kit, 81’ 6014400080 140.00
Power Required: 9-30 VDC (750Ω load @ 24VDC) 316 SS cable suspension mounting kit, 101’ 6014400100 165.00
LIQUID LEVEL Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
178 TRANSMITTERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Magnetostrictive Gauges for Liquid Level Measurement


MTS’ Level Plus® M-Series liquid level gauges offer you unsurpassed
flexibility to meet most process application conditions. M-Series gauges
are modular in design, offering you a selection of electronics housing
styles, sensor pipe styles, and materials of construction.
The M-Series gauge features a removable sensing element. At any
time, without disturbing the operation of your process, you can remove
the sensor element and electronics housing.
Prices
Flow Measurement

Rigid gauges, available in lengths to 25 feet, come standard with rigid


Start at
Instruments

sensor elements. The rigid sensor pipe style comes with an end plug.

$1200
Flexible gauges are available in lengths up to 40 feet, and come stan-
dard with flexible sensor elements. Flexible pipe models can be ordered
with bottom-fixing hooks, weights, or magnets. Optional flexible sensor
elements can be ordered with rigid pipe configurations.
Up to two 4–20 mA loops are available for analog indication of level,
interface, and temperature. HART® communication allows the M-Series
gauge to indicate and display all three measurement variables simul-
taneously.
Solids Flow and Motion

Setup, calibration, and diagnostics are available from any point in


the loop using a standard HART handheld programmer. An optional
Features on-board display and keypad is also provided for local indication and
programming.
• For foam, interface, and emulsions
The M-Series gauges can also incorporate an RTD for spot temperature
• For liquid levels with specific gravity <1.9 measurement of your process.
• Ultralow dielectric constant
• Level and temperature in one probe Specifications
• 1/32” accuracy Output: 4-20 mA, 2 loops with HART interface
• Built-in 100-point strapping table for temperature-adjusted Range: Flexible: 120”–480” (3050–11890 mm); Rigid: 20”–300” (508–7620 mm)
mass/volume calculations Non-Linearity: Flexible: 0.035% full scale (independent BSL) or 1/32“ (0.794
Rotary and Electric

mm); Rigid: 0.020% full scale (independent BSL) or 1/32” (0.794 mm)
• Rigid model for tanks up to 25 feet tall
Actuator Motors

Repeatability: Flexible: Up to 0.01% full scale or 0.015” (0.381 mm); Rigid: Up


• Flexible model for tanks from 25 to 65 feet tall to 0.005% full scale or 0.005” (0.127 mm)
• HART® communications Operating Temperature: Sensor: -40° to 257°F (-40° to 125°C); Electronics:
-30° to 160°F (-34° to 71°C)
Humidity: 0 to 100% R.H., non-condensing
Principle of Magnetostriction Vessel Pressure: Dependent on float pressure rating
The liquid level gauge is composed
Input Voltage: 10.5–36.1 VDC; Reverse polarity protection by series diode
of three concentric members. The
outermost member is a protective, Transient Protection: Stage 1: Line-to-ground surge suppressors; 2500
media-compatible outer pipe that Amps peak (8/20 µsec) Stage 2: Line-to-line and line-to-ground transient
withstands aggressive or harsh pro- suppressors; 1500 Watts peak (10/1000 µsec)
Combustion Safety

cess industry applications. Calibration: Zero Adjustment: Anywhere within the active length; Span: Full
and Efficiency

scale ≥ 0.5 ft. (152 mm) from zero


The middle element has an RTD
mounted on it for accurate tempera- Temperature Output: 4-20 mA from Pt1000Ω RTD at 0°C; Accuracy: ±2.7 °F
ture measurement. (±1.5°C); Repeatability: ±0.18°F (0.1°C); Drift: ±0.9°F (0.5°C) per year; Calibra-
tion: Zero Adjustment: -40° to 255 °F (-40 to 124°C); Span: 45° to 300°F (7.2°
The heart of the gauge design is the to 149°C) full scale
innermost element — the waveguide
Wetted Materials: 316L stainless steel
— a formed element made of a pro-
prietary magnetostrictive material. Length (including housing): 20” to 40 ft. (508 to 12,192 mm)
A low current interrogation pulse Mounting: Adjustable fitting, 3/4” NPT (rigid), 1” NPT (flex)
is generated in the gauge elec- Wiring: 2-wire connection, shielded cable or twisted pair to screw terminals
and Communications
Wireless Instruments

tronics, and transmitted down the through a 3/4” NPT conduit opening. NEMA 4X, 15 ft. (457 cm) pigtail inte-
waveguide, creating an electromagnetic field along the length of gral cable or Daniel Woodhead (P/N 70807SS) 6-pole Male 1/4”–18; MNPT
the waveguide. key-way receptacle.
When this magnetic field interacts with the permanent field of a Optional Display: 16 digits, 0.5” (12.7mm); Measured variables: Level 1, Level
magnet mounted inside the float,a torsional strain pulse (or waveguide 2 and temperature; Update rate: 3 sec
twist) results. The waveguide twist is detected as a return pulse. HART® Communications: 1200 bps; 1 start bit, 1 stop bit, 8 data bits, 1 odd
The time period between the initiation of the interrogation pulse parity bit; digital frequency 1200 to 2200 Hz
and the detection of the return pulse is used to determine the level Approvals: FM/CSA; Explosion Proof: Class I, Groups B-D, Class II, Groups E-G,
measurement with a high degree of accuracy and reliability. Div 1, NEMA 4X (in explosion-proof housing); Intrinsically Safe: Class I, Groups
A-D, Class II, Groups E-G, Div 1, NEMA 4X
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan LIQUID LEVEL

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TRANSMITTERS 179

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
LESMAN
Instrument Company
Name: ____________________________________________________
Company: _ _______________________________________________
Street: ____________________________________________________

www.lesman.com City: _ _______________________ State: __________ Zip: __________


Phone: ( ____ )________________ Fax: ( ____ )___________________
Bensenville Office Milwaukee Office
Phone: 800-953-7626 Phone: 800-837-1700 E-mail Address: _ ___________________________________________
Fax: 630-595-2386 Fax: 262-790-5579 This is a: ■ Request for Quote ■ Order: PO#_________________

Flow Measurement
E-mail: sales@lesman.com Quantity Needed: _ ____________ Date Required: _____/_____/____

Instruments
Contact: _______________________________ Ext. _________ Shipping Method: _____________ Partials Accepted: ■ Yes ■ No

Magnetostrictive
Gauge Choose the style gauge you need. Then fill in the yellow boxes
below (order length, 4 mA, and 20 mA location) with the appropriate
Application Datasheet values for your installation and process.

Solids Flow and Motion


Rotary and Electric
Actuator Motors
Gauges <48” Gauges >48”
Inactive Sensor<25’ Sensors 25’–40’
Zones 316SS, Hastelloy C 2.9” 2.9”
Inactive Zone 3.0” 3.8”
Teflon 4.2” 5.2”

Combustion Safety
and Efficiency
Model #: _______________________________ Quantity:____________ Signal Output: 4-20 mA
Loop 1 (Check One) n Level 1 n Level 2 n Temperature
Sensor Pipe Material: _________________________________________
Loop 2 (Check One) n Level 1 n Level 2 n Temperature
Housing Type (Check One): n None n NEMA 4X
n Single Cavity n Single Cavity with Display Alarm Setting (Check One) n Low (3.8 mA) n High (21.5 mA)
n Dual Cavity n Dual Cavity with Display Approval Required (Check One):
Flange/Process Connection: _ __________________________________ n FM n CSA n Explosion-Proof n Intrinsically Safe
Market Description (Check One)
and Communications
Wireless Instruments

Level 1 Float Part No:_ ________________________________


n FB Food and Beverage n PR Petroleum Production
Float Material:_ ___________________________________________
n CH General Chemical n RE Petroleum Refining
Pressure:_________________________________________________
n HP High Value Petrochemicals n PB Pharmaceutical/Biotech
Specific Gravity:___________________________________________
n LP LPG/LNG n SG Sight Glass
Level 2 Float Part No:_ ________________________________ n PE Petrochemical n SV Solvents
Float Material:_ ___________________________________________ n MA Petroleum Marketing n TR Transportation
Pressure:_________________________________________________ n PL Petroleum Pipeline n US Ultrapure Chemicals/
Specific Gravity:___________________________________________ Semiconductor
BUBBLER Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
180 SYSTEMS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Using a Siemens Transmitter as a Bubbler for Liquid Level


The bubbler system is an inexpensive but accurate means of mea-
suring the fluid level in open or vented containers, especially those in
harsh environments such as cooling tower sumps, swimming pools,
reservoirs, vented fuel tanks, drain sumps, or air washers. The system
consists of a source of compressed air, air flow restrictor, sensing tube,
and pressure transmitter. The only component of the bubbler system
that is exposed to the elements is the sensing tube. All other compo-
Flow Measurement

nents can be remotely located in a protected area.


Instruments

91-HF Combination
SITRANS P Pressure Filter-Regulator Advantages
Transmitters
• Not affected by foam or turbulence
Series 62 Constant
Differential Relay • Can be used in small diameter pipes
• Easy to understand/proven technology
Air Bubbler Theory
• Large installed base
1 A constant flow of pressurized air is applied to the tube
2 A pressure transducer monitors the air pressure in the tube Common Applications
3 The pressure in the tube is equal to the pressure at the bot- • Determine head through a flume or weir
Solids Flow and Motion

tom of the tank • Level in a lift station


4 The liquid level equals the pressure in the tube divided by • Tank level when foam is present
the density of the liquid • Can be used with atmospheres other than air
5 As long as the material density remains constant, the pres-
sure is proportional to the liquid level in the tank

SITRANS P Pressure Transmitters Series 62 Constant-Differential Relay


• Gage Pressure Transmitters used • Provides constant air flow volumetric rate
for vented or open top vessels • Eliminates the effects of variations
Rotary and Electric
Actuator Motors

• Differential Pressure Transmitters in the plant air supply


used for pressurized or sealed • Includes rotometer for air flow
vessels indication
• Supply Pressure: Maximum: 150
“SITRANS P” psig; minimum: 5 psi above highest
output pressure required
t Siemens • Rotometer Pressure: 200 psig max
Learn more abou
r gage pressure • Materials: Relay: Aluminum, brass, stainless steel, Neoprene,
transmitters fo differential Buna-N; Rotometer: Glass, stainless steel, polycarbonate, boro-
on 152–153 and 6–157.
Combustion Safety

silicate, Viton, and Kynar®


pressure on 15
and Efficiency

Ordering Instructions
91-HF Combination Filter-Regulator Make one selection from each table section below. A complete part number looks like
• Output: 0–120 psig (0–800 kPa) this: Bubbler-100-Switch
• Supply Pressure: 150 psig max. Model Selection Guide
• Flow Capacity: 22 SCFM at 100 Catalog
psig (33 m3/Hr at 700 kPa) Description Number Price
• Exhaust Capacity: 0.1 SCFM Siemens Bubbler System — Assembled and ready to be installed.
and Communications
Wireless Instruments

with downstream pressure 5 Price includes 24” x 24” Hoffman concept enclosure with a DP
transmitter, constant differential relay and filter regulator. BUBBLER- $2990.00
psig above setpoint (0.17 m3/Hr
Range 1-100” H2O Transmitter 7MF4433-IDA22-1AC6-Z+A01 -100- 0.00
at 35 kPa) 2.4-240” H2O Transmitter 7MF4433-1EA22-1AC6-Z+A01 -240- 0.00
• Materials: Diecast aluminum alloy, 6.4-640” H2O Transmitter 7MF4433-1FA22-1AC6-Z+A01 -640- 0.00
irridite and baked epoxy finish, Options Pressure Switch — Lets you know if you’ve lost plant air -Switch 240.00
nitrile elastomer and Nylon fabric diaphragm, Pressure Switch and Horn — Gives both a switch to wire
nitrile elastomer valve seat plug back to plant alarming systems and a audible alarm
for local notification -Switch/Horn 340.00
• Port Size: (In, Out, and Gauge) 1/4” NPT Level Indication Panel -Indicator 275.00
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan LIQUID LEVEL

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TRANSMITTER 181

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Flange Mounted Smart Transmitter for Liquid Level
Ordering Instructions
Make one selection from each table section below. Check the restriction letters to be
sure the unit you need is available. A finished catalog number looks like this:
STF924-A2C-00000-CC1C-XXXX
“STF924”
Model Selection Guide
Description Model Avail. Price

Flow Measurement
0-25 to 0-400” H2O / 0-25 to 0-1000 mbar STF924 ↓ $1503.00

Instruments
0-5 to 0-100 PSI / 0-0.35 to 0-7 bar STF932 ↓ 1624.00
0-25 to 0-400" H2O / 0-25 to 0-1000 mbar STF92F ↓ 1409.00
Flush Carbon Steel Reference Head, 316 SS Vent/Drain
Mount Valve, Barrier Diaphragm, Diaphragm Plate A _ _ • 0.00
316 SS Reference Head, Vent/Drain Valve, Barrier
Diaphragm, and Diaphragm Plate E _ _ • 48.00
316 SS Reference Head, Vent/Rain Valve, Hastelloy
C Barrier Diaphragm, Diaphragm Plate F _ _ • 201.00
All Hastelloy C Wetted Parts J _ _ • 689.00
Extended Mount, All 316 Stainless Steel Wetted Parts R _ _ • 260.00

Solids Flow and Motion


Pseudo CS Reference Head, 316 SS Vent/Drain Valve,
Flange Barrier Diaphragm, Diaphragm Plate A _ _ • 0.00
Features Fill Silicone _ 1 _ • • 0.00
• Flush, flange, extended mounts available Fluid C T F E _ 2 _ • • 63.00
Process 1⁄4” NPT Ref. HD, High Pressure Side Flange _ _ A • • 0.00
• 16:1 or 20:1 turndown ratio Conn. 1⁄2” NPT (w/ Adapter), High Pressure Side Flange _ _ H t t 0.00
• 4-20 mA or digital output No Selection 0_ _ _ _ • • 0.00
Flange 3” ANSI Class 150, Carbon Steel _1_ _ _ • 0.00
• Configurable with Hart® handheld or Honeywell SFC 3” ANSI Class 150, 304 Stainless Steel _A_ _ _ • 154.00
Smart Field Communicator 4” ANSI Class 150, 304 Stainless Steel _D_ _ _ • 227.00
• Most popular options shown here. Call if you don’t Pseudo 3” ANSI Class 150, Vent/Drain, 316 Stainless Steel _R_ _ _ • 106.00
see what you need. Flange 3” ANSI Class 300, No Vent/Drain, 316 SS _P_ _ _ • 0.00
No Selection _ _0_ _ • 0.00

Rotary and Electric


Actuator Motors
Gasket Flush Design, 316 Stainless Steel _ _1_ _ g 0.00
Ring Flush Design, Hastelloy C _ _2_ _ g 366.00
Specifications Exended Design, 316 Stainless Steel _ _5_ _ v 0.00
Turndown Ratio: STF924,92F: 16:1; STF932: 20:1 No Selection _ _ _00 • 0.00
Flush _ _ _ F0 h 0.00
Recommended Minimum Span: STF924,92F: 25” H2O (37.5 mbar);
Model STF932: 5 PSI (0.35 bar) Extension 2” long _ _ _C0 v 126.00
1.87” Diameter(for 2”, 3” or 4” spud) 4” long _ _ _D0 v 138.00
Zero Elevation and Supression: No limit (except minimum span) 6” long _ _ _E0 v 154.00
from 0 Abs. to ±100% URL. Specs valid from -100% to 100% URL.
Explosion Proof Class I, Div. 1, Gr A–D
Accuracy: Analog mode: Model STF924,92F: Greater of ±0.10% cali- FM Dust-Ignit Proof Class II, III, Div. 1, Gr E–G 1C • • 0.00
brated span or upper range value (URV). 0.05 + 0.05(50”H2O/span Approval Non-Incendive Class I, Div. 2, Gr A–D
“H2O) in % span. STF932,93F: Greater of ±0.10% calibrated span or Intrinsic Safety Class I, II, III, Div. 1, Gr A–G
URV, terminal based. 0.05 + 0.05(30 PSI/span PSI) in % span. Digital

Combustion Safety
None 00 • • 0.00
mode: STF924, 92F: ±0.075% span; STF932, 93F: ±0.075% span.

and Efficiency
Adapter Flange – 1⁄2” NPT ST Steel S3 • • 13.00
Combined Zero and Span Temperature Effect per 28°C (50°F): Adapter Flange – 1⁄2” NPT Hastelloy C T3 b • • 67.00
STF924, 92F: ±0.6% span; STF932, 93F: ±0.6% span Lightning Protection LP • • 60.00
Options Analog Meter (0-100 even, 0-10 Sq. Rt.) ME • • 161.00
Combined Zero and Span Static Pressure Effect per 300 PSI (21 Smart Meter (Digital) SM • • 161.00
bar): STF924, 92F: ±0.40% of span; STF932, 93F: ±0.25% span HART® Communications Protocol HC • • 42.00
Output (Two-Wire): 4 to 20 mA, or digital communications NACE A-286SS Bolts & Nuts for Head/Adapters CR • • 82.00
Supply Voltage Effect: 0.005% span per volt Restrictions
Damping Time Constant: Adjustable from 0 to 32 seconds b Options not available together. Select only one.
RFI Protection: Negligible effect (20 to1000 MHz at 30 V/meter) g Available only with body styles A_ _, E_ _, F_ _, J_ _
h Not available with Table 2 meter body selections R_ _, S_ _, and extended design
and Communications

Electronic Housing: Low copper aluminum; NEMA 4 (watertight)


Wireless Instruments

and NEMA 7 (explosion-proof ). selection _ _5_ _ from Table 3 flange assemblies.


t Select the adapter flanges from Table 3 options (S1 or T1)
Process Connections: Reference leg side: 1⁄4” NPT female (1⁄2” NPT
with adapter);Tank side: Flange:3”or 4”,Class 150 or 300 ANSI; DN80- v Available only with Table 2 meter body selection R_ _.
PN40 or DN100-PN40 DIN flange; Extended diaphragm: 2”,4”,or 6”;
Sanitary flange: 4” sanitary tank spud, Ladish 4” Tri-Clamp Windows® Configuration
Wiring: Accepts up to 16 AWG (1.5mm diameter) Software Available!
Hazardous Conditions: Meets requirements of explosion-proof See Page 146.
and intrinsically safe systems for North American Class I, Groups
A–D, Division I (explosion-proof systems, Groups B–D only),
CAPACITANCE Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
182 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Sitrans LC300 Capacitance Continuous Level


The new SITRANS LC300 is a cost effective instrument for level mea-
surement in high accuracy applications. It performs in liquids, bulk solids
SITRANS LC300 and slurries, including viscous (conductive or non-conductive) materials,
even in challenging environments involving vapor and dust.
The LC300 is a 2-wire level measurement instrument combining a
Features sophisticated, yet easy-to-adjust microprocessor with field-proven Poin-
• Accurate and cost-effective level tek CLS300 Probes. It is available in two versions: rod and cable/rope. All
Flow Measurement

measurement wetted parts are made of stainless steel with a PFA Teflon insulator for
high chemical resistance.
Instruments

• Shear- and abrasion-resistant probe


The LC300 probe is normally mounted on the vessel top or through
• 2-wire loop powered isolated 4-20mA the tank wall at the detection level (if used as a Point Level switch). The
• Integrated local display cable version is designed for top mounting.The cable suspends vertically
so that it reaches into the process at the desired detection level for high
• Push-button calibration or low detection alarm.
• Patented Active-Shield Sitrans LC300 combines high accuracy and reliability with low
capacitance technology maintenance and ease of installation. The unique inverse-frequency
• Fully adjustable range: level, damping approach to capacitance technology provides high resolution and
and diagnostics long-term stability. The patented Active-Shield technology protects the
Solids Flow and Motion

measurement from the effects of moisture, vapors, foam, temperature


• Current signaling according to NAMUR or pressure variations and material build up. Its advanced electronics
NE 43 provide for simple calibration, and its integrated local display make
• Corrosion-resistant construction and wet- on-site installation and set up easy. The two-wire transmitter complies
ted parts with NAMUR NE 43 for current signaling.
• 82 ft. (25 m) maximum insertion length Modular construction features a full range of NPT connections and DIN
and ANSI flanges, as well as corrosion-resistant PFA and 315L stainless
• Sanitary rod optional steel wetted parts to suit virtually any application.
Not sure if the LC300 is right for you? The LC300 uses a switched power supply circuit that makes the most
efficient use of available power present on the terminals. If the signal
Complete a level application datasheet on current is low (4 mA), the terminal voltage will increase due to a voltage
page 439 and send it to Lesman. We’ll help you drop of other components in the loop. If the signal current is high (20
find the perfect fit for your process.
Rotary and Electric

mA), the terminal voltage will decrease.


Actuator Motors

Specifications Dimensions
Media: Liquids, bulk solids, slurries with a 1.5 minimum dielectric constant Rod Cable/Rope
Measurement Range: 0-3300 pF; minimum span 3.3 pF Version Version
Measurement Frequency: 600 kHz maximum
Accuracy: <0.5% of actual measurement value
Temperature Stability: 0.25% of actual capacitance value
Nonlinearity/Reproducibility: <0.4% /full scale and actual value
Current Signaling: According to NAMUR NE 43, signal 3.8 to 20.5mA, fault
≤ 3.6 or ≥ 21mA (22mA)
Combustion Safety

Output Current Loop: Continuous signal 4 to 20mA/20 to 4mA


and Efficiency

Probe Diameter: Rod Version: 0.75” with or without PFA jacket; Rope/Cable
Version: 0.24” without PFA jacket, 0.35 “ with
Probe Lengths: Rod: 14” to 40”; Rope/Cable: 20” to 985”
Active Shield Length: Rod: 3.94”; Rope/Cable: 4.92”
Maximum Tensile Force: 1900kg (4188 lbs); Horizontal: 30Nm (rod version)
E.S.D Probe Protection (kV): Protected to 55kV continuous discharge
Wetted Parts: AISI 316L/PFA/PEEK™
User Interface: Display local LCD, 4 digits capable of displaying numbers
0 to 9 and limited alpha characters
and Communications
Wireless Instruments

Wiring Connections: Maximum 2.5mm2 (PED/97/23/EC)


Process Connection: Threaded: 3/4” to 11/2” NPT; Flanges: 1” to 4” ANSI
Enclosure: Aluminum and epoxy coated construction; NEMA 4/Type
4/IP65; 2 x 1/2” NPT cable inlet
Process Conditions: -14.6 to 511 psig (-1 to 35 Barg) pressure range;
-40° to 392°F (-40° to 200°C)
Supply Voltage: 9-32 VDC any polarity, 2-wire loop (9V @ 22mA)
Environmental: Indoor/outdoor location, 2000m max. altitude, -40° to
185°F (-40° to 85°C), relative humidity suitable for outdoors (Type 4/
NEMA 4/IP65 enclosure), installation category II, pollution degree 4
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CAPACITANCE

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 183

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Ordering Instructions
Make one selection from each table below. A complete catalog number
What’s the Right Level Technology?
looks like this: 7ML5605 - _ _ _ _ _-Z Need help figuring out which level measurement
instrumentation to use in your process? Start with the
Model Selection Guide reference charts below. Find your media type, process
conditions, and tank design to
Avail- Catalog Key
help narrow down your choices.
Description ability Number Price ▲ Excellent: Recommended.
Depending on your application,
SITRANS LC300, Threaded Connection ↓ 7ML5625 - $492.00 l Good: Works in most cases.
there may be more than one tech-
SITRANS LC300, Welded Flange Connection ↓ 7ML5626 - 492.00 u Fair: Works, but others are better.

Flow Measurement
nology for you.
Version (For process connections 1-1/4” and larger) Dont’t forget to include ▼ Poor: Do not use.

Instruments
Insertion Length (Option Y01_ _ _ _ below.)
Rod, PFA Insulated, 300–1000 mm • • 0A _ _ _ - 80.00

Vibratory Fork
Rotary Paddle
Rod, PFA Insulated, 1001–2000 mm • • 1A _ _ _ - 160.00

Capacitance
Point Level

Ultrasonic
Rod, PFA Insulated, 2001–3000 mm • • 2A _ _ _ - 240.00
Rod, PFA Insulated, 3001–4000 mm • • 3A _ _ _ - 320.00 Technologies

Floats
Rod, PFA Insulated, 4001–5000 mm • • 4A _ _ _ - 400.00
Rod, PFA Insulated, Stilling Well, 300–1000 mm • • 0B _ _ _ - 200.00 Media Properties
Rod, PFA Insulated, Stilling Well, 1001–2000 mm • • 1B _ _ _ - 400.00 Liquids - Clean l ▼ ▼ ▲ ▲
Rod, PFA Insulated, Stilling Well, 2001–3000 mm • • 2B _ _ _ - 600.00
Liquids - Coating ▼ ▼ ▼ l ▲
Rod, PFA Insulated, Stilling Well, 3001–4000 mm • • 3B _ _ _ - 800.00
Slurries ▼ ▼ ▼ l ▲

Solids Flow and Motion


Rod, PFA Insulated, Stilling Well, 4001–5000 mm • • 4B _ _ _ - 1000.00
Cable, PFA Insulated, Weighted, 1000–2000 mm • • 0E _ _ _ - 40.00 Liquid/Liquid Interfaces ▼ ▼ ▼ ▲ ▼
Cable, PFA Insulated, Weighted, 2001–4000 mm • • 1E _ _ _ - 80.00 Liquid/Solid Interfaces ▼ ▼ ▼ ▼ ▼
Cable, PFA Insulated, Weighted, 4001–6000 mm • • 2E _ _ _ - 120.00 Solids - Low Dust ▼ l l l l
Cable, PFA Insulated, Weighted, 6001–8000 mm • • 3E _ _ _ - 160.00 Solids - High Dust ▼ l l l ▼
Cable, PFA Insulated, Weighted, 8001–10000 mm • • 4E _ _ _ - 200.00 Process Environment
Cable, Non-Insulated, Weighted, 1000–2000 mm • • 0F _ _ _ - 10.00 Vapors l ▼ ▼ l ▼
Cable, Non-Insulated, Weighted, 2001–4000 mm • • 1F _ _ _ - 20.00 Foam u ▼ ▼ u ▼
Cable, Non-Insulated, Weighted, 4001–6000 mm • • 2F _ _ _ - 30.00
Temp >350°F ▼ ▼ ▼ ▼ ▼
Cable, Non-Insulated, Weighted, 6001–8000 mm • • 3F _ _ _ - 40.00
Cable, Non-Insulated, Weighted, 8001–10000 mm • • 4F _ _ _ - 50.00 Pressure >50PSI l ▼ ▼ l ▼
Vacuum l ▼ ▼ l ▼
Process Connection Size
Turbulence ▼ ▼ l l l
3/4” NPT Thread (Rod Versions Only) • _ _ A0 _ - 0.00 Tank Design and Structural Properties
1” NPT Thread (Rod Versions Only) • _ _ B0 _ - 20.00 Agitators ▼ ▼ l l l

Rotary and Electric


1.5” NPT Thread • _ _ C0 _ - 46.00

Actuator Motors
Obstructions l l l l l
1.25” NPT Thread • _ _ K0 _ - 27.00
1”, ANSI, 150 lb, AISI 316L Stainless Steel • _ _ A1 _ - 156.00
1”, ANSI, 300 lb, AISI 316L Stainless Steel • _ _ A2 _ - 190.00

Magnetostrictive
1”, ANSI, 600 lb, AISI 316L Stainless Steel • _ _ A3 _ - 200.00

Head Pressure
1.5”, ANSI, 150 lb, AISI 316L Stainless Steel • _ _ B1 _ - 188.00

Capacitance
1.5”, ANSI, 300 lb, AISI 316L Stainless Steel • _ _ B2 _ - 220.00 Continuous Level

Ultrasonic
Load Cells

1.5”, ANSI, 600 lb, AISI 316L Stainless Steel • _ _ B3 _ - 240.00


Bubbler
Technologies

Radar
2”, ANSI, 150 lb, AISI 316L Stainless Steel • _ _ C1 _ - 224.00
2”, ANSI, 300 lb, AISI 316L Stainless Steel • _ _ C2 _ - 251.00
Media Properties
2”, ANSI, 600 lb, AISI 316L Stainless Steel • _ _ C3 _ - 290.00
3”, ANSI, 150 lb, AISI 316L Stainless Steel • _ _ D1_ - 267.00 Liquids - Clean ▲ ▲ ▲ ▲ ▲ ▲ ▲
3”, ANSI, 300 lb, AISI 316L Stainless Steel • _ _ D2_ - 326.00 Liquids - Coating ▲ ▼ u ▼ l ▲ ▲
3”, ANSI, 600 lb, AISI 316L Stainless Steel • _ _ D3_ - 352.00 Slurries ▲ ▼ l ▼ l ▲ ▲

Combustion Safety
4”, ANSI, 150 lb, AISI 316L Stainless Steel • _ _ E1_ - 321.00 Liquid/Liquid Interfaces ▼ ▼ ▼ ▲ ▲ l ▼

and Efficiency
4”, ANSI, 300 lb, AISI 316L Stainless Steel • _ _ E2_ - 413.00 Liquid/Solid Interfaces ▼ ▼ ▼ ▼ ▼ ▲ ▼
4”, ANSI, 600 lb, AISI 316L Stainless Steel • _ _ E3_ - 490.00 Solids - Low Dust u ▼ ▼ ▼ u ▲ u
General Purpose • • ____1- 0.00 Solids - High Dust u ▼ ▼ ▼ u ▼ ▲
Dust Ignition Proof, CSA/FM • • Liquid - Shifting Specific Gravity ▼ ▼ ▼ ▼ ▲ ▲ ▲
Approvals (Class II, III Div 1, Group E-G T4) • • ____2- 15.00 Dielectric <2 ▲ l u l ▼ ▲ l
Explosion Proof, CSA/FM 183 • • Shifting Dielectric ▲ l ▲ l ▼ ▲ ▼
(Class I Div 1, Group A-D) • • ____4- 80.00 Process Environment
Enclosure Epoxy-Coated Aluminum, IP65 • • 0 _ _ _ 0.00 Vapors l l l l l ▼ ▲
Epoxy-Coated Aluminum, IP68 • • 2 _ _ _ 30.00 Foam u u l ▲ ▼ ▼ ▼
None • • _ AA _ 0.00 Temp >350°F ▲ l l ▼ l ▼ ▲
and Communications

Options Thermal Isolator • • _ BA _ 45.00


Wireless Instruments

Pressure >50PSI ▲ ▼ l ▲ l ▼ ▲
Mounting Eye 2 • • _ CA _ 49.00 Vacuum ▲ ▼ l ▲ l ▼ ▲
Thermal Isolated, Mounting Eye 2 • • _ DA _ 94.00 Turbulence ▲ u l u ▼ l l
Transmitter None • • _ _ _ 0 -135.00 Tank Design and Structural Properties
3300 pF, (2-Wire 4-20 mA Loop) • • _ _ _ 1 0.00 Agitators ▲ u l u ▼ l l
Total Insertion Length • • Y01 _ _ _ _ 0.00 Obstructions ▲ u l u l l l
Add-Ons Stainless Steel Tag (Max. 20 Char) • • Y15 (text) 35.00
Instruction Manual • • 7ML1998-5HE01 5.25 Still not sure what you need? Fill out a level application
Electronic Transmitter Kit • • 7ML1830-1KN 270.00 datasheet on page ___ and fax it to Lesman for an
Notes: 2 Available on cable versions only. engineering review.
CONTINUOUS Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
184 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Sitrans LC500 Capacitance Continuous Level Detection System


What Makes LC500 Different?
Active shield technology provides low initial capacitance for higher sensitivity in materi-
als with low dielectrics, and higher resolution for greater measurement accuracy. Active
shield eliminates the drift associated with condensation and stray capacitance buildup
between the electronics and the measuring surface.
LC500’s accuracy is stated as a percent of the measured value, not as a percent of span
or range. This allows for tighter level control, especially critical when you’re measuring
Flow Measurement

levels of high-cost products or when your process requires close level tolerances. You’ll
Instruments

be able to more closely monitor maintenance and safety situations, like tank overflows
or hazardous materials backups.
Even with a limited number of probes, the LC500 offers the broadest range of tempera-
ture and pressure applications of any manufacturer in the industry. Probes can withstand
temperature extremes of -328° to 752°F and pressures from full vacuum to 7,665 PSI. The
rugged probe design ensures long life, increased up-time, and reduced maintenance.
It’s easy to calibrate an LC500 probe. An LC500 can be configured wet or dry with the
probe in place, using switch configuration in the electronics box, a
Hart® handheld or a Hart HPC01 pocket communicator.
Solids Flow and Motion

The MSP2002 two-wire loop-powered transmitter includes


galvanically isolated measurement circuits that prevent ground loops. A fully potted
transmitter reduces the effects of moisture in the transmitter housing and provides
strong resistance to vibration. The certified transmitter housing permits use in installa-
tions requiring explosion/flameproof or intrinsically safe approvals.
You can calibrate the 4-20 mA span with the press of a button.Using a HART communica-
tor, DCS, or laptop remote setup in non-hazardous area provides enhanced safety for plant
personnel. You can monitor the loop current locally without interrupting loop wiring.
The MSP2002 transmitter includes HART protocol for comm­unications and local or
remote setup.The HART system provides information on measured variables, tag numbers,
range and span settings, and other diagnostic information.
Choose from many probe configurations and materials, including rigid rod and flow-
• Reliable, Accurate Level Measurement
Rotary and Electric

through electrode models, to find the combination perfect for your application.
Actuator Motors

— Active shield technology offers high accu- The LC500 probe is unaffected by vapors, product deposits, dust, or condensation, and
racy, stability, repeatability, and linearity and is it performs in: Liquids oil, water, chemicals, acids, caustics, beverages; Solids granulate,
unaffected by vapors, product deposits, dust, sugar, coal dust, plastics; Interfaces high pressure coalescers, glycol regenerators, heater
and condensation treaters, desalters, separators, storage tanks, gas and oil tankers, floating production stor-
• One Universal Transmitter — Single two- age offshore (FPSO) ships; Slurries adhesives, paper pulp, glucose, drilling mud
wire current loop 4-20 mA transmitter fits a Transmitter Specifications
number of probes Measurement Range: 0 to 3300 picofarad; Span: 3.3 picofarad min
• Simple, Push-Button Calibration — Rapid, Supply Voltage: Max: 33 VDC; Min: 12 VDC at 3.6 mA, 9.5 VDC at 22 mA
cost-effective commissioning with quick, easy Measurement Current: 3.6 to 22 mA/22 to 3.6 mA (2-wire loop powered)
installation
Combustion Safety

Temperature Range: Without thermal isolator: -328° to 392°F (-200° to 200°C); With thermal
• Can be Used in Conductive and Noncon-
and Efficiency

isolator: Depends on temperature range of the probe


ductive Materials — Chemi­cal resistant and Temperature Stability: Greater of 0.15 pF or 0.1% actual measurement value over full range.
suitable for high pres­sure and high tempera- Accuracy: <0.1% of actual measurement value; Nonlinearity/Reproducibility: <0.1% full scale
ture applications
Features: Polarity protection input circuit; E.S.D. protected; Galvanically isolated measurement
• Smart Transmitter (HART® Protocol) — For circuit; Fully potted with Epoxy resin
fast, easy on-site or remote commissioning/in- Diagnostics: Includes fault alarm when primary variable (PV) out of limits; system failure in
spection measurement circuit; deviation between A/D and D/A converter; check sum; watch dog;
• Safety Approvals — Suitable for use in measurement current out of range
extreme conditions and FM/CSA approved for Measurement Current Signaling: NAMUR NE 43
use in hazardous areas
and Communications

Approvals: CE: Complies with requirements of E.C.C. as per EN 55011


Wireless Instruments

and EN 50082-2; Cenelec: EEx ia IIC T6...T4, EEx ia IIB T6-T4 (intrinsically
nership
Low Cost of Ow
safe), EExd [ia] IIC T6-T4 (explosion proof ), Ex nC IIC T4 (non-sparking
proof ); Class I-II, Div. 2, Class III, Div. 1-2 (hazardous locations); FM: Class
✓ Lower maintenance costs due to measure-
■ I-III, Div. 1, Groups A-D (explosion proof ); 3A sanitary
ment stability and probe robustness (con- For help with your application, fill out the capacitance
stant dielectric, no frequent calibrations) application datasheet on page 438 and fax it to Lesman
✓ Reduced stocking requirements and training
■ for an engineering review. If you know you need an
✓ Reduced downtime (no frequent calibrations)
■ LC500, use the LC500 datasheet on page 442.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan CONTINUOUS

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 185

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Standard Combinations of LC500 Probes
Features Series S Series D Series SD Series DD Series HP Interface Sanitary
Process Threaded ✓ ✓
Connection Flanged ✓ ✓ ✓ ✓ ✓ ✓
Types Tri-Clamp ✓
Sanitary Thread ✓
Process Stainless Steel AISI 316L ✓ ✓ ✓ ✓ ✓ ✓ ✓

Flow Measurement
Connection Carbon Steel C22.8 N ✓ ✓ ✓
Materials Duplex Steel ✓

Instruments
Hastelloy1 B2 or C22 ✓
Monel 400 ✓
Tantalum ✓
Probe PFA ✓ ✓ ✓ ✓ ✓ ✓ ✓
Insulations PE2 ✓
Ceramic ✓ ✓
Length Max Rod Length 216” 216” 216” 216” 100” N/A 216”
Parameters Max Cable Length 1378” 1378” 1378” 1378” N/A 1378” N/A
Max Pressure3 2900 PSI 2175 PSI 2175 PSI 2175 PSI 7613 PSI 73 PSI 145 PSI
Max Temperature3 392°F 392°F 392°F 392°F 842°F 212°F 392°F

Solids Flow and Motion


1 Flange made of AISI-316L SS with a 0.19” welded Hastelloy plate. 2 For general purpose applications only. 3 Depends on range.

Level/Interface — Ordering Instructions Sanitary Models — Ordering Instructions


Make one selection from each table below. A complete catalog number Make one selection from each table below. A complete catalog
looks like this: 7ML5514 - _ _ _ _ _ - _ _ _ _ - Z - _ _ _ _ number looks like this: 7ML553_ - _ _ _ _ _ - _ _ _ _ - Z - _ _ _ _

Please submit orders to: Siemens, Please submit orders to: Siemens,
Model Selection Guide c/o Lesman Instrument Company Model Selection Guide c/o Lesman Instrument Company
Catalog Catalog
Description Number Price Description Number Price
LC500-S Continuous Contacting Level and Interface LC500 Continuous Contacting Sanitary Level and Interface Measurement

Rotary and Electric


Measurement Transmitter, S-Series Seal 7ML5514 - $465.00 Transmitter, Tri-Clamp Coupling, S-Series Seal, PFA Insulation, 316L Probe

Actuator Motors
Electronic None 0 _ _ _ _ - 0.00 0.63” Rod Version 7ML5534 - 465.00
Transmitter MSP2002-2 (3300pF) 1 _ _ _ _ - 760.00 0.95” Rod Version 7ML5535 - 570.00
3/4” Thread, NPT _ AA0 _ - 0.00 Electronic None 0 _ _ _ _ - 0.00
Process 1” Thread, NPT _ BA0 _ - 5.00 Transmitter MSP2002-2 (3300pF) 1 _ _ _ _ - 760.00
Connection 1.25” Thread, NPT _ CA0 _ - 11.00 Process 2” O.D., Welded Clamp Diameter _ BA10 - 10.00
Size 1.5” Thread, NPT _ DA0 _ - 15.00 Connection 3” O.D., Welded Clamp Diameter _ CA10 - 15.00
2” Thread, NPT _ EA0 _ - 20.00 4” O.D., Welded Clamp Diameters _ DA10 - 25.00
Probe PFA (316L Stainless Steel) _ _ _ _ 1 - 0.00 General Purpose 0A _ _ - 0.00
Insulation PFA(Hastelloy C) _ _ _ _ 2 - 200.00 Approvals FM/CSA Non-Incendive Hazardous Area 0E _ _ - 60.00
Enamel (316L Stainless Steel) (Note 1) _ _ _ _ 3 - 1380.00 FM/CSA Intrinsically Safe 0F _ _ - 120.00
FM Explosion Proof 0G _ _ - 165.00
None 0 _ _ _ - 0.00

Combustion Safety
Stilling Well 1.42”, 316SS (Connection D or E) 1 _ _ _ - 3.00/In Thermal None _ _ A1 - 0.00
Isolator or Rigid Isolator (Transmitter Exceeds 185°F) _ _ B1 - 50.00

and Efficiency
Diameter 1.9”, 316SS (Connection E) 2 _ _ _ - 4.00/In
(Note 2) 1.42”, Hastelloy C (Connection D or E) 3 _ _ _ - 10.00/In Remote Remote Mounted Electronics with 79”
1.9”, Hastelloy C (Connection D or E) 4 _ _ _ - 11.00/In Mounted Cable and Mounting Bracket _ _ C1 - 125.00
Electronics Remote Mounted Electronics with 158”
General Purpose _ A _ _ - 0.00 Cable and Mounting Bracket _ _ E1 - 150.00
Approvals Non-incendive Hazardous Area _ B _ _ - 60.00
(Note 3) Intrinsically Safe _ C _ _ - 120.00 Enter Total Insertion Length and Active Shield Length Z-
Explosion Proof _ E _ _ - 150.00 Probe 0.95” Rod (specify length in inches) Y01 _ _ _ _ 2.50/In
Options Active Shield Length in Inches Y02 _ _ _ _ 0.00
Probe 0.63” Rod (138” Max.) _ _ A _ - 0.00
Diameter 0.95” Rod (217” Max.) _ _ B _ - 50.00 English Instruction Manual 7ML1998-5GE01 15.75
Thermal None _ _ _ 0 - 0.00 Notes
Isolator or Rigid Isolator (Exceeds 185°F) _ _ _ 1 - 90.00 1 Available with probe/electrode diameter C only.
and Communications
Wireless Instruments

Remote Remote Mount Electronics with Maximum length 60”.


Mounted 79” Cable, Mounting Bracket _ _ _ 2 - 125.00 2 Stilling well choice to be the same material as the
Electronics Remote Mount Electronics with process connection material option selected above.
158” Cable, Mounting Bracket _ _ _ 4 - 150.00
Enter Total Insertion Length and Active Shield Length Z-
Probe PFA Insulation (specify in Inches) Y01 _ _ _ _ 2.00/In
Length Enamel Insulation (specify in Inches) Y01 _ _ _ _ 23.00/In
Need a HART® handheld
Active Shield Length in Inches Y02 _ _ _ _ 0.00 communicator or an RS-232 to HART
modem? See page 147.
ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
186 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

The Probe: Ultrasonic Continuous Level Transmitter


Siemens brings you a much easier way to measure
liquid levels without the problems of invasive
mechanical devices — The Probe!
Features
• Noncontacting Award-Winning Integrated Design: This sleek, durable package combines
the sensor and electronics in a single molded body. Electronics are potted
• Proven ultrasonic technology in rugged PVC; the wetted part, encasing the transducer and temperature
Flow Measurement

• One-piece design sensor, is made of injection-molded Tefzel, a fluoropolymer inert to most


Instruments

chemicals. The seamless sensor housing resists buildup and cleans easily.
• Easy to install and calibrate It is ideal for corrosive environments and in applications where cleaning
• Measurement reliability and washdowns are frequent.
• Versatile range of options Sonic Intelligence™: The Probe provides ultrasonic measurement reliability,
maintenance-free operation, and Sonic Intelligence. Siemens’ advanced
• Low maintenance
software effectively discriminates between real and false echoes to add to
• Built-in temperature compensation the inherent accuracy of the unit. So, the Probe meets your needs in the de-
• Two-year guarantee manding applications where conventional contacting methods can fail.
Simplicity: Bolt, clamp, or screw the unit to the mounting surface above the
Solids Flow and Motion

material being monitored.You won’t need to empty the tank.And,unlike load


“Milltronics Probe” cells, there are no special mechanical considerations. Because the compact
one-piece unit houses both sensor and electronics, you can connect wiring
easily through one of the two cable entry knockouts.
Two-Step Calibration: Open the Probe’s hinged lid to access the control panel
Specifications Dimensions for calibration push-buttons and data display. With the material at its cor-
Measurement Range: 0.8 ft. to 16.4 ft. (0.8 responding 4 mA (low) level, push the 4 button twice. With the material at
ft. to 26.2 ft. extended range for 3-wire its corresponding 20 mA (high) level, press the 20 button twice. That’s it!
models)
Low Maintenance Costs: Probe’s ultrasonics and advanced design lower
Operating Conditions: Temperature: -40° maintenance costs dramatically in comparison to competitive technologies.
to 140°F contin-uous (-5°F with metallic There are no mechanical moving parts and, as a result, the unit requires no
mount). Built-in temperature compensa- periodic maintenance due to fouling or wear.
tion. Pressure: 14.5 PSI (in vessel) max.
Rotary and Electric

static.
Actuator Motors

mA Output: Range: 4–20 mA;Accuracy: 0.25% Ordering Instructions


target range (air); Resolution: 0.125”; Load- Make one selection from each table section below. A complete catalog number
ing: 3-Wire: 750Ω max. @ 24 VDC; 2-Wire looks like this:7ML1201 - _ _ _ _ _
Loop-Powered: 800Ω @ 28 VDC max. load.
Please submit orders to: Siemens,
Power: 3-Wire: 18–30 VDC supply, 5w (200 Model Selection Guide c/o Lesman Instrument Company
mA @ 24 VDC) max. consumption; 2-Wire Loop Powered: 23–28 VDC
Catalog
supply, 0.75w (25 mA @ 28 VDC) max. consumption
Description Number Price
Selectable Damping: Immediate, 5m-, 1 m- or 0.03m/min. The Probe: Ultrasonic Level Transmitter 7ML1201 - $750.00
Beam Angle: 10° @ -3 dB boundary. Measuring 16.5 Feet (5 meter) 1 _ _ _ _ 0.00
Integrated Housing: Electronics: Molded PVC; Transducer: Seamless Range 26 Feet (8 meter) 2 _ _ _ _ 50.00
Combustion Safety

Tefzel® or Kynar Flex. Sensor ETFE (Tefzel), 2” NPT _ A _ _ _ 30.00


and Efficiency

Enclosure Rating: IP65, NEMA 4X, Type 4 ETFE, 2” BSP _ B _ _ _ 27.00


ETFE, PF2 _ C _ _ _ 27.00
Mounting: 2” threaded NPT
PVDF Copolymer (Kynar Flex), 2” NPT _ E _ _ _ 0.00
Cable Entry: Two 0.87” holes for 0.5” conduit connector. PVDF Copolymer, 2” BSP _ F _ _ _ 0.00
Approvals: 3-Wire: CSA, FM approved for general use, CE; PVDF Copolymer, PF2 _ G _ _ _ 0.00
2-Wire Loop-Powered: CSA approved for general use, In- Model and 3 Wire, 24 VDC, CSA/CE/FM _ _ E00 0.00
trinsically safe (IS version only), CSA/FM Class I and II, Div. Approval 2 Wire, CE _ _ F00 0.00
1, Groups A-G, BASEEFA/CENELEC EExiaIICT4, CE. (Note 1) 2 Wire, IS, ATEX, CSA, FM _ _ G00 200.00
Accessories
Power Supply, 24 VDC, 200 mA, for Two Probes PBD-24900034 220.00
and Communications

Power Supply, 24 VDC, 100 mA, for One Probe PBD-24900016 115.00
Wireless Instruments

Paper Tag PBD-45000673 25.00


Stainless Steel Tag PBD-51028073 35.00
Universal Box Bracket Mounting Kit 7ML1830-1BK 95.00
Universal Mounting Adapter for 3” Flange, 2” NPT 7ML1830-1BT 110.00
Catalog Instruction Manual for 24 Volt 3-Wire Probe 7ML1998-1GD61 15.00
Description Number Price Instruction Manual for 2-Wire Probe 7ML1998-1GC61 15.00
The Probe Ultrasonic Level Sensor: In-Stock! 7ML1201- $750.00 Note 1: Two-wire models available with 16.5 foot range only.
5M, 2” NPT ETFE, 24 VDC 3-Wire, CSA/CE/FM 1AE00 30.00
5M, 2” NPT ETFE, 2-Wire, CE 1AF00 30.00 Due to contractual agreements with our manufacturers, some products are
5M, 2” NPT PVDF, 2-Wire, CE 1EF00 0.00 NOTE: not available in all areas or markets. Call Lesman for more information.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 187

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
MiniRanger Plus Ultrasonic Level Transmitter
“Milltronics Miniranger”

Specifications
Operating Range: Liquids: From 1 to 50 ft. (0.3 to 15m); Solids: From 1 to 25
ft. (0.3 to 10m) (Subject to Application Approval)
Accuracy: Greater of 0.25% range or 0.24”; Resolution: 0.08” over full range

Flow Measurement
Echo Processing: Patented Sonic Intelligence™ software.

Instruments
Measurement Response: Selectable from 0.1 m/min to 1020m/min.
Intelligent Sensing Made Simple! Operating Temperature: Electronics: -40 to 140°F (-40 to 60°C)
• Low cost of ownership; No maintenance Power: 100/115/200/230V ±15%, switch selectable; 50/60 Hz, 15 VA
• Ranges — Liquids: 50 ft.; Solids: 25 ft. mA Output: Optically isolated 0/4-20 mA.
• Optically isolated 4-20 mA output; 2 alarms Relay Output: 2 alarm/pump control relays,1 Form C SPDT contact
per relay, rated 5A at 230 VAC non-inductive hard gold plate.
• Remote programming
Approvals: CE, CSA, FM.
• Available in rack-, panel-, and wall-mount models
Wall Mounted Enclosure: Chemical resistant polyester/polycar-

Solids Flow and Motion


bonate alloy. Size: 9 x 5 x 2.75”. Rated IP65, NEMA 4X.
Siemens’ MiniRanger Plus comes in streamlined, low-cost rack- and
panel-mount models that will fit into your existing system. Both models Display: 1.5 x 4” multifield LCD with bargraph
offer you the reliability and exceptional performance of the wall-mount Transducers: Echomax XPS10, XPS15, XCT, XCT12 transducers. STH.
unit, with added convenience and adaptability. Transducer Cable Extension: Up to 1200 ft. with RG-62A/U coaxial cable.
This low-cost, single-point ultrasonic level monitor uses the same
advanced Sonic Intelligence™ echo processing software found in our
more sophisticated systems.It comes with two relays and a true isolated
4-20mA output — just what you need to get the job done right without A complete level transmitter system includes:
the tangles, plugging, and downtime associated with contacting pres- 1. Transceiver
2. Transducer (see pages 198 and 199)
sure transmitters, bubblers, capacitance probes, and floats. 3. Additional cable and optional flanges, as necessary
The MiniRanger Plus can control a two-pump lift station, or one 4. Aiming kits, software, and communications, as needed
pump and a high alarm shutoff, or a high and a low alarm, or any other

Rotary and Electric


combination of pumps and alarms.

Actuator Motors
Ordering Instructions
Make one selection from each table section below. Complete catalog numbers
Choose Your Transducer look like this:7ML1016 - _ _ _ _ _ - _ _ _ _ and 7ML1841 - _ _ _ _ _
Siemens offers several Echomax transducers
used in harsh environments at temperatures Please submit orders to: Siemens,
from ‑40° to 203° F. High temperature Model Selection Guide c/o Lesman Instrument Company
XCT8 and XCT12 models are rated for Catalog
temp­eratures as high as 293° F. Description Number Price
Built-in temperature compensation is MiniRanger Plus: Ultrasonic Transceiver Electronics 7ML1016 - $810.00
standard with any Echomax transducer. No additional cable is needed, Wall 1_ _ _ _ - 0.00
so you save on wiring and installation costs. An optional submersible Mounting Rack 2_ _ _ _ - 80.00
shield assures valid readings, even when the transducer is immersed Panel 3_ _ _ _ - 171.00

Combustion Safety
in flood conditions. Input and Universal Power Supply, 9–250VAC/DC _ A _ _ _ - 0.00

and Efficiency
Outputs 4 to 20 mA, Isolated Analog Output _ _ A _ _ - 0.00
Dolphin Plus Configuration Software Standard Volume _ _ _ 11 - 0.00
Laptop Programming: Perform a com­plete Feature Volume Calculations and Level _ _ _ 21 - 100.00
setup via an optical link with Siemens patented Software Flow Calculations and Level _ _ _ 31 - 100.00
Dolphin Plus Windows-based software.You can Approvals CE, CSA (for Wall Mount Only) 0AA1 0.00
change any parameter, back up and restore CE, CSA, FM (for Rack/Panel Versions) 0AA2 0.00
parameters to a PC disk, and update the soft- Paper Tag PBD-45000673 25.00
ware in flash memory, all without opening the Stainless Steel Tag PBD-51028073 35.00
wiring panel. Accessories Terminal Block for Rack Mount Unit 7ML1830-1JL 110.00
Dolphin prompts you with the relevant parameter descriptions and English Instruction Manual 7ML1998-1CJ02 15.00
and Communications
Wireless Instruments

online help needed to program the host unit.Complete parameter setup Dolphin Plus Configuration Software 7ML1841- 200.00
for each unit can be saved to and restored from a floppy disk, or dupli- No Options -0AA00 0.00
cated for programming multiple units with the same configuration. Options With RS485 to RS232 Link -1AA00 110.00
With Comverter -0AA11 175.00
With RS485 to RS232 Link, Comverter -1AA11 275.00

Need help finding the right level system for your process?
Take a look at our Level Technology Selector on page 183 to narrow down your choices. Then, complete an application
datasheet on page 438 and fax it to Lesman. We’ll have an engineer review your process and specify the best instrument fit to
meet your needs. Call us toll free or visit www.lesman.com for a copy of the datasheet.
ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
188 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

SITRANS Probe LU for Ultrasonic Level Measurement


Features
• Continuous level measurement up to 12 m (40 ft) range
• Easy installation and simple startup — set two parameters and go!
• Patented Sonic Intelligence signal processing
• Auto False-Echo Suppression for fixed obstruction avoidance
• Short blanking distance, even on long range applications
Flow Measurement

• Programming using Siemens’ infrared intrinsically safe handheld programmer, HART®


Instruments

communicator, or Siemens SIMATIC PDM software and a laptop PC


• ETFE or PVDF transducers for chemical compatibility
• Built-in alphanumeric display — visible through the transparent lid
SITRANS Probe LU is a two-wire loop powered ultrasonic transmitter for level, volume, and flow
monitoring of liquids in storage vessels and simple process vessels, as well as in open channels.
The Probe LU is ideal for level monitoring in the water/wastewater industry and for overseeing
chemical storage vessels.
Solids Flow and Motion

Siemens took the time-tested Milltronics Probe and applied new revolutionary features — includ-
ing the latest microprocessor and communication technologies.The low noise transmitter and noise
shield result in an excellent signal-to-noise ratio, providing higher accuracy and reliability.
You can choose a SITRANS Probe LU with either an ETFE or a PVDF transducer to suit the chemi-
cal conditions of your application. Both have built-in temperature sensors, to compensate for the
varying process temperatures in your application.
Using the handheld infrared programmer, you can set up the unit or change configurations
without ever opening the lid — even in hazardous areas.

Siemens’ Self-Learning Echo


Rotary and Electric

Suppression Technology
Actuator Motors

Features
• Patented self-learning algorithm is standard in all Siemens non-
contacting instruments
• No laptop PC or special software required
• Five-minute setup eliminates false echoes
• Accessible via $100 infrared handheld programmer
The Simple Solution
You’ll run Siemens’ self-learning algorithm when the tank is empty Before
Combustion Safety

or near empty.
and Efficiency

To implement the automatic obstruction suppression feature with the


handheld programmer, you need to know (a) where the actual level is
and (b) the distance from the transducer face to the material level.
1. On the handheld, select parameter P838 and key in the distance from
the transducer face to the material level minus 0.5m.
2. Select parameter P837, press 2, and press ENTER.
After a few seconds, the level device calculates the new echo profile,
and automatically modifies the filter around the area of the obstruction
to ignore its echo.
and Communications
Wireless Instruments

Before: The BLUE line represents the echo being returned to the level
instrument, including all echoes from obstructions. The RED line repre-
sents a default filter applied by the unit to suppress the nominal noise
returned with the echo. The first echo could be from an agitator or tank
brace. The second signal is the data you really want: the reflection from
the surface of the level being measured.
After: The level unit is instructed to“learn”where the obstructions (false
After
echoes) are between the device and the level of the material.The RED line
represents the“learned filter”that is set above the false echoes, screening
them out. All that’s left is the “true” echo from the material surface.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 189

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Programming Profiles for Accurate Tank Level Monitoring
Problem: The original ultrasonic measuring devices for making the equipment operate made several
purchased for this new sewage treatment plant visits to the job site to relocate and reconfigure the
wouldn’t accurately measure level. units in an attempt to make them work. The contrac-
tor couldn’t satisfy the performance requirements
User’s Existing Business Results demanded by the engineering team. Costs kept
• False Echoes: False echo signals from fixed and adding up, and measurements still weren’t accurate.
moving obstructions in a sludge concentrator

Flow Measurement
made the device unable to provide reliable level Business Results After Installation

Instruments
measurement. • The original units were replaced with Siemens
• Meeting Performance Requirements: The contractor responsible SITRANS Probe LU ultrasonic level units. The self-learning feature
was used to ignore the obstructions that produced false echoes.
Read this and other customer success stories Each unit was up and running just 15 minutes after installation.
at www.lesman.com/success/css_application.htm

Dimensions Connecting the Probe LU

Solids Flow and Motion


Rotary and Electric
Specifications Ordering Instructions

Actuator Motors
Measuring Range: 10” to 20’ (6M) or 10” to 40’ (12M); Blanking Distance: 10” Make one selection from each table section below. A complete catalog
(0.25M); Beam Angle: 10° at -3 dB boundary number looks like this:7ML5221 - _ _ _ _ _
Accuracy: Greater of ±0.15% range or ±0.25”; Repeatability: ≤3 mm (0.12”); Please submit orders to: Siemens,
Resolution: ≤3 mm (0.12”) Model Selection Guide c/o Lesman Instrument Company
Frequency: 54 KHz (ultrasonic) Catalog
Description Number Price
Update Time: <5 seconds
SITRANS Probe LU: Ultrasonic Level Transmitter 7ML5221 - $800.00
Output: 4-20 mA; Accuracy: ±0.02 mA
Measuring 20 Ft (6M) ETFE 2A _ _ _ 50.00
Temperature: Ambient: -40 to 176 °F (-40 to 80 °C); Process temperature at Range 20 Ft (6M) PVDF Copolymer 2B _ _ _ 00.00
flange or threads: -40 to 185 °F (-40 to 85 °C) 40 Ft (12M) ETFE 2C _ _ _ 250.00
Temperature Compensation: Built in to compensate over full range 40 Ft (12M) PVDF Copolymer 2D _ _ _ 190.00

Combustion Safety
and Efficiency
Power: Nominal 24 V DC with max. 550Ω; 30 V DC max.; 4 to 20 mA Commun- HART® and 4-20 mA Output _ _ A1 _ 0.00
ication Profibus _ _ A2 _ 150.00
Enclosure: PBT polymer, hard-coated polyether imide lid; Type 4X/NEMA
4X, Type 6/IP68 protection Approvals General Purpose FM, CSA, CE _ _ _ _ 1 0.00
(Note 1) Intrinsically Safe FM, ATEX _ _ _ _ 2 200.00
Sensor: EFTE (Tefzel) or PVDF (Kynar®) FM Class I Div 2 _ _ _ _ 4 0.00
Process Connection: Threaded: 2” NPT, BSP, or G/PF; Flange: 3” universal Accessories
Cable Inlets: Two 1/2” NPT threads Intrinsically Safe Handheld Programmer 7ML5830-2AH 100.00
Design: Rotating head aligns with conduit for easy wiring, and adjusts for Universal Mounting Adapter for 3” Flange, 2” NPT 7ML1830-1BT 110.00
optimal visibility English Instruction Manual 7ML1998-5HT02 20.00
Quick-Start Guide 7ML1998-5QR81 25.00
Local Display: Alphanumeric display, visible through the transparent lid
HART® Modem for Use with PC and Simatic PDM 7MF4997-1DA 355.00
and Communications
Wireless Instruments

Communication: HART® standard, integral to analog output; Configuration Note 1: Approval Option 1 only available with Profibus communication
using Siemens SIMATIC PDM (PC) or HART handheld communicator, or
Siemens infrared hand programmer
See page 147 for details and pricing on Simatic PDM.
Programming: Set up for use with as few as two parameters. No echo profile
required at startup; Built-in volume conversion for eight most common Looking for low-cost radar level detection?
tank shapes including custom linearization table See the SITRANS Probe LR on page 203.
Approvals: ATEX Ex II 1 G, EEx ia IIC T4, SIRA certificate 01ATEX2147; ATEX
hazardous area II 1G EEx ia IIC T4; FM Class 1, Div. 1, Groups A-D (barrier Due to contractual agreements with our manufacturers, some
required); Class II, Div. 1, Groups E-G; Class III; CSA Class I, Div. 1, Groups A-D NOTE: products are not available in all areas or markets. Call Lesman for
(barrier required); Class II, Div. 1, Group G; Class III more information.
ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
190 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

MultiRanger 100/200 Ultrasonic Level Transceiver System


MultiRanger Innovation:
Direct
Built-in Control Algorithms
r
retrofit fo MultiRanger MultiRanger
your old Control/Monitoring Functions 100 200
s
Milltronic er
MultiRang Fixed or Alternating Pump Sequences ✓ ✓
Plus
Pump Service Ratio Predetermination ✓
Flow Measurement

Next Pump Duty Assist or Backup Assist Only ✓


Instruments

Pump Starts/Running Hours ✓ ✓


Point Level Contact Override ✓ ✓
100-230 VAC or 12-30 VDC ✓ ✓
Dual Point Measurement Option ✓ ✓
Level, Rate, Temperature, Fault Alarms Some ✓
Advanced Pump Control Modifiers ✓ Many
“Milltronics Multiranger”
Pumped Volume Total ±5% Accuracy
Solids Flow and Motion

Volume Conversion ✓
• Dual point or single point monitoring option Open Channel Flow Conversion/Totaling ✓
• MultiRanger 200 functions include open channel flow moni- Two 4-20 mA Outputs ✓ ✓
toring, volume, pump control, pump volume 3 or 6 Relays, 2 Discrete Outputs ✓ ✓
• Digital communications, with built-in Modbus RTU over 4-20 mA Alternate Level Input ✓
RS485 connection, and easy compatibility with PLCs using RS232/RS485 Modbus Ports ✓ ✓
SmartLinx® interface modules SmartLinx Module Compatible ✓ ✓
• Compatible with Dolphin Plus software for easy parameter
setup, diagnostics, and viewing of echo profiles
• Advanced echo-processing software offers fine-tuning pa- The new generation of Siemens MultiRanger ultrasonic level transceiver
rameters for superior measurement reliability offers unsurpassed reliability, digital communications, and the latest
Rotary and Electric
Actuator Motors

• Improved signal-to-noise ratio for enhanced reliability technology features in a cost-effective package. This multi-functional
level monitor is ideal for appli­cations up to 50 feet.
• Use the MultiRanger 200’s 4-20 mA input to connect to an-
MultiRanger 100 offers cost-effective level monitoring. MultiRanger
other level measurement device
200 provides high performance measurement of level, flow, and volume
• Overfill protection feature: a float, point level detector, or conversion, with additional alarm and pump control functions.
contact device wired into MultiRanger will override the level MultiRanger now has digital communications with built-in Modbus
monitor as a failsafe against overfilling RTU and an RS485 port. It readily connects to Profibus-DP, Allen-Brad-
• System protection: mA outputs are isolated from ground to ley Remote I/O, and Devicenet through Siemens SmartLinx® interface
protect your equipment, PLCs, and chart recorders modules. Using an external modem, you can connect remotely by phone
line to collect data from the MultiRanger.
• Easy diagnostics let you download the program or echo
MultiRanger stores all instrument configuration, operation, and proc­
Combustion Safety

profile and e-mail it to a service technician for review


ess data in Modbus registers for easy acquisition and modifi­cation using
and Efficiency

any common interface or SCADA software.This lets you remotely access


MultiRanger Innovation: Over/Underfill Prevention data and functions, such as level and temperature values, alarm and
Automatic system overrides on measurement fault detection.The sys- control setpoint adjustment, pump usage data for remote main­tenance
tem assumes user-defined level and corresponding operation when: scheduling, and instrument status and diagnostics.
• Self-detected loss of echo (LOE): Damaged transducer or cable, MultiRanger includes six time-varying-threshold (TVT) curves,10 echo-
excessive signal attenuation processing algorithms,echo profile shaping,and filters.This enhances the
• Point level device input: Transducer blanking encroachment, foam reliability of the level reading, facilitates more difficult applications, and
on monitored surface, obstruction detection assists with equipment servicing. As you select parameters during setup,
it automatically selects the best algorithms for your application.
SmartLinx Interface Modules Several new features offer enhanced performance. MultiRanger lets
and Communications
Wireless Instruments

• Enable direct connection to a PLC you connect a float, point level detector, or contact device to override
or data communications network the level instrument as a failsafe against overfilling. In addition, an mA
without external interfaces input is standard on the MultiRanger 200, allowing you to connect a
• Can be field installed at any time, or non-ultrasonic device. The two mA outputs are isolated from ground
replaced with another protocol if fu- to protect equipment, PLCs, and chart recorders.
ture bus connection needs change
• Available for Allen-Bradley Remote View or download full specifications and operation
I/O, Profibus DP, Modbus RTU, Devi-
ceNet, and telephone modem manuals at www.lesman.com
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 191

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Specifications Compatible Echomax Transducers
Range: 1 to 50 ft. (depending on transducer)
XPS-10/10F
Accuracy: Greater of 0.25% of maximum
XPS-15/15F
Resolution: Greater of 0.1% program range or 0.08”
Inputs (Model 200 Only): mA analog: 0-20 mA or 4-20 mA, from alternate
XCT-8, XCT-12
device, scalable; Discrete: 10-50 VDC switching level; logical 0 = <0.5 VDC, XRS-5
logical 1 = 10-50 VDC; 3 mA max. draw

Flow Measurement
Dimensions
Outputs: mA outputs: 0-20 mA or 4-20 mA; Transducer drive: 315V peak, 44

Instruments
KHz; Relays: Three: 2 Form A/ 1 Form C; Six: 4 Form A/2 Form C. (All relays
rated at 5 Amp at 250 VAC, non-inductive.)
Temperature: Compensation: ‑58° to 30°F; Source: Integral transducer sensor,
TS-3 temperature sensor, programmable fixed temperature; Error: Sensor:
0.09% range; Fixed: 0.17%/°C deviation from programmed value
Display: 4” x 1.5” multi-field backlit LCD
Programming: Handheld programmer or PC with Dolphin Plus software
Communication: RS232 running Modbus RTU or ASCII via RJ11 connector,
RS485 running Modbus RTU or ASCII via terminal blocks

Solids Flow and Motion


Power Supply: AC model: 100-230 VAC ±15%, 50/60 Hz, 36 VA
(17W); DC Model: 12-30 VDC (20W)
Cable: Signal to be 2-3 copper conductors, twisted with
shield (braided screen preferred), drain wire 300V, 0.5mm2
(22-18 AWG)
Enclosure: Polycarbonate Type X/NEMA 4X, IP65
Environment: Indoor/outdoor; Altitude: 6561 ft.; Installation
category: II; Pollution degree: 4
Approvals (Pending): CE, FM, UL Listed; CSA Class I, Div. 2 Grp.
A-D, Class II, Div. 2 Grp. F-G, Class III

Rotary and Electric


Actuator Motors
Ordering Instructions
Make one selection from each table below. A complete catalog number looks like this:
7ML5033 - _ _ _ _ _ - _ _
MultiRanger 100 for Level, Wall Mount, AC Input
Voltage, Single Point, SmartLinx-Ready, 3 Relays, CE, Please submit orders to: Siemens,
CSA, Approved Model Selection Guide c/o Lesman Instrument Company
7ML5033-1AA00-1A.....................................................$1195.00 Catalog
MultiRanger 200 for Level, Volume, and Flow, Wall Description Number Price
Mount, AC Input Voltage, Single Point, SmartLinx- MultiRanger: Transceiver Electronics 7ML5033 - $1175.00
Ready, 3 Relays, CE, CSA, Approved
Model MultiRanger 100, Level Measurement Only 1 _ _ _ _ - 0.00
7ML5033-2AA00-2A................................................$No Match! MultiRanger 200, Level, Volume, and Flow 2 _ _ _ _ - 275.00

Combustion Safety
and Efficiency
Mounting Wall, Standard Enclosure _ A _ _ _ - 0.00
A complete level transmitter system includes: Panel Mount _ C _ _ _ - 55.00
1. Transceiver Input 100 to 230 VAC _ _ A _ _ - 0.00
2. Transducer (compatible with ST-H, XRS-5, XPS‑10, XPS‑10F, Voltage 12 to 30 VDC _ _ B _ _ - 0.00
XPS‑15, XPS‑15F, XCT‑8, and XCT‑12) Software Single Point System _ _ _ 0 _ - 0.00
3. Additional cable lengths, as necessary Dual Point System _ _ _ 1 _ - 220.00
4. Handheld programmer/calibrator
Data SmartLinx Ready (No Module) _ _ _ _ 0 - 0.00
5. Optional flanges, as necessary Communi- SmartLinx A-B Remote I/O Module _ _ _ _ 1 - 700.00
6. Aiming kits, software, and communications, as necessary cations SmartLinx Profibus-DP Module _ _ _ _ 2 - 510.00
SmartLinx Devicenet Module _ _ _ _ 3 - 510.00
Need help finding the right Output 3 Relays: 2 Form A, 1 Form C (250 VAC) 1 _ 0.00
and Communications
Wireless Instruments

Relays 6 Relays: 4 Form A, 2 Form C (250 VAC) 2 _ 110.00


level system for your process?
See page 438 of this catalog for a copy of the Siemens level Approvals CE, CSA, FM Pending, UL Listed Pending _ A 0.00
datasheet. Complete the form and fax it to Lesman. We’ll English Instruction Manual 7ML1998-5FB04 35.00
have an engineer review your process and specify the best Quick-Start Guide 7ML1998-5QD82 15.00
instrument fit to meet your needs. MultiRanger 100/200Handheld Programmer 7ML1830-2AK 100.00
Accessories SmartLinx Allen-Bradley Remote I/O Disk 7ML1830-1AD03 15.00
SmartLinx Profibus DP Data Disk 7ML1830-1AQ03 10.00
Due to contractual agreements with our manufacturers, SmartLinx Devicenet Data Disk 7ML1830-1BH02 20.00
NOTE: some products are not available in all areas or markets.
Call Lesman for more information.
192 WASTEWATER
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
Phone: 800-953-7626 • 630-595-8400 Phone: 800-837-1700 • 262-790-5578
MONITORING www.lesman.com
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

HydroRanger 200 Wastewater Monitoring and Control System


Features Specifications
• Single point level monitor- Range: 1 to 50 ft. (dependent on transducer)
ing for wet wells, weirs, and Accuracy: Greater of 0.25% of maximu range or 0.24”
flumes Resolution: Greater of 0.1% program range (defined as the empty distance
• Six relays standard to the face of the transducer plus any range extenson) or 0.08”
• Digital communications Inputs: mA analog: 0-20 mA or 4-20 mA, from alternate device, scalable;
Flow Measurement

with RS485/Modbus RTU Discrete: 10-50 VDC switching level; logical 0 = <0.5 VDC, logical 1 = 10-50
VDC; 3 mA max. draw
Instruments

• Compatible with Dolphin Outputs: mA outputs: 0-20 mA or 4-20 mA., max. loading 750Ω, 0.1% relolu-
Plus configuration software Direct retrofit tion; Transducer drive: 315V peak; Relays: Six: 4 Form A/2 Form C. (All relays
SmartLinx® communication for your old rated at 5 Amp at 250 VAC, non-inductive.)
modules Milltronics
s
HydroRanger Plu
Temperature: Compensation: Range: ‑58° to 30°F; Source: Integral trans-
• Anti-grease ring/tide mark ducer sensor, TS-3 temperature sensor, programmable fixed temperature;
buildup Error: Sensor: 0.09% of range; Fixed: 0.17% °C deviation from programmed
value
Display: 4” x 1.5” multi-field backlit LCD
Programming: Primary: Handheld programmer; Secondary: PC running
Solids Flow and Motion

HydroRanger is a non-contacting level monitoring controller that Dolphin Plus software


features advanced relay alarming, differential level measurement, open Communication: RS232 running Modbus RTU or ASCII via RJ-11 connec-
flow monitoring, and volume conversion. tor, RS485 running Modbus RTU or ASCII via terminal blocks, SmartLinx®
For water authorities, municipal water, and wastewater plants, HydroR- compatible with RS485 modem kit
anger is an economical, low-maintenance solution delivering control Power Supply: AC model: 100-230 VAC ±15%, 50/60 Hz, 36 VA (17W); DC
efficiency and productivity needed to meet today’s exacting standards. Model: 12-30 VDC (20W)
It offers single-point monitoring with 6 relays standard, as well as digital Transducers: Echomax® series and ST-H series
communications with built-in Modbus RTU via RS485.
Enclosure: Polycarbonate Type X/NEMA 4X, IP65
HydroRanger is compatible with Dolphin Plus, allowing for PC con-
Cable: Transducer and mA output signal to be 2-3 copper conductors, twisted
figuration and setup. Sonic Intelligence® advanced echo-processing with shield (braided screen preferred), drain wire 300V, 0.5 to 0.75mm2
software provides increased reading reliability. (22-18 AWG)
HydroRanger uses Siemens continuous ultrasonic echo ranging tech- Environment: Location: Indoor/outdoor; Altitude: 6561 ft.; Installation cat-
Rotary and Electric

nology to monitor water and wastewater of any consistency up to 50


Actuator Motors

egory: II; Pollution degree: 4


feet in depth. Achievable resolution is 0.1% with accuracy to 0.25% of
Dimensions (HWD): 9.45” x 6.325” x 3.58”
range. Unlike contacting devices, HydroRanger is immune to problems
caused by suspended solids, harsh corrosives, grease or silt in the efflu- Approvals (Pending): CE (EMC performance available on request), FM, CSA,
ent, reducing downtime. UL Listed; CSA Class I, Div. 2 Grp. A-D, Class II, Div. 2 Grp. F-G, Class III

Compatible Transducers Ordering Instructions


XPS-10/10F Make one selection from each table section below. A complete catalog number
looks like this: 7ML5034 - _ _ _ _ _
XPS-15/15F
Combustion Safety

XCT-8, XCT-12
and Efficiency

Please issue all orders to: Siemens,


XRS-5 Model Selection Guide c/o Lesman Instrument Company.
For more on Echomax transducers, see pages 198–199. Catalog
Description Number Price

Dolphin Plus Software Makes HydroRanger 200 Wastewater Monitor/Control System


Mounting Wall, Standard Enclosure
7ML5034 -
1 _ _ _ _ -
$1195.00
0.00
Setup a Snap! Panel Mount 3 _ _ _ _ - 55.00
Dolphin Plus is a Windows®-based Input 100 to 230 VAC _ A _ _ _ - 0.00
program that allows complete param- Voltage 12 to 30 VDC _ B _ _ _ - 0.00
eter setup and downloading from the Feature Single Point System _ _ A _ _ - 0.00
and Communications
Wireless Instruments

HydroRanger through a laptop or other Software Dual Point System _ _ B _ _ - 220.00


PC.Dolphin Plus prompts the user during Data SmartLinx Ready (No Module) _ _ _ 0 _ - 0.00
operation with the relevant parameter Communi- SmartLinx A-B Remote I/O Module _ _ _ 1 _ - 700.00
descriptions and online help needed to cations SmartLinx Profibus-DP Module _ _ _ 2 _ - 510.00
program the host unit. SmartLinx Devicenet Module _ _ _ 3 _ - 510.00
Complete parameter setup for each Approvals CE, CSA, FM, UL Listed _ _ _ _ 1 0.00
unit can be saved to and restored from Handheld Programmer 7ML1830-2AK 100.00
a floppy disk, or duplicated for program- Accessories Dolphin Plus Remote Programming Kit 7ML1841-1AA00 310.00
ming multiple units with the same configuration. See page 187 for Additional English Instruction Manual 7ML1998-5FC01 35.00
ordering information. All models ship with one English user’s manual. *Approvals pending.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan WASTEWATER

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
MONITORING 193

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
EnviroRanger ERS500: For Liquid Level Monitoring
• Monitors level in liquid applications up to 50 feet
• Monitors flow in flumes, weirs, or open channels
• Calculates pumped volume to accuracy within 5%
• Built-in communications interface (Modbus RTU/ASCII)
• Controls any combination of pumps, gates, and alarms
• Integrates pumps and components for effective liquid

Flow Measurement
level monitoring and control

Instruments
• Tracks data for trend analysis Lift station
• Logs time, date, duration, and volume of up to 20 occurrenc- control in a
es of combined sewer overflows single box!
• Logs pump run time and number of pump starts
• Automatically cleans bar screens ERS500
• Generates scheduled reports or reports on demand or by
exception to help you optimize your system’s effectiveness

Solids Flow and Motion


• AC or DC power with rack, panel, or wall mounts available
• System configuration and diagnostics with Dolphin Plus
Windows®-based software
• ECT, EnviroRanger Configuration Toolkit software for ad-
vanced configuration with graphics templates and datalog-
ging functions

Specifications Ordering Instructions


Power: AC: 100-230 VAC ±15%, 50/60 Hz, 36 VA (17W); DC: 12-30 VDC (20W) Make one selection from each table below. A complete catalog number looks
Environmental: Location: Rack/Panel mount:Indoor;Wall mount:Indoor/out- like this: 7ML1001 - _ _ _ _ _ - _ _ _ _

Rotary and Electric


Actuator Motors
door; Altitude: 6,561 feet; Ambient temperature: -5° to 122°F; RH: Rack/Panel
mount: 80% RH for temperatures to 122°F; Wall mount: Suitable for outdoor Please submit orders to: Siemens,
(Type 4X,NEMA 4X,IP65 enclosures); Installation category: II;Pollution degree: Model Selection Guide c/o Lesman Instrument Company
Rack/Panel mount: 2; Wall mount: 4 Catalog
Scan Points: 1 or 2 points Description Number Price
Range: 1 feet to 50 feet, dependent on transducer EnviroRanger ERS500 Ultrasonic Level Meter 7ML1001- $1520.00
Accuracy: Greater of 0.25% of maximum range or 0.24” Panel 1 _ _ _ _ - 165.00
Mounting Rack 2 _ _ _ _ - 0.00
Resolution: Greater of 0.1% of program range (empty distance to face of Wall (Standard Enclosure) 3 _ _ _ _ - 0.00
transducer plus range extension) or 0.24”
Input 100 to 230 VAC _ A _ _ _ - 0.00
Memory: 1 MB static RAM with battery backup, 1 MB flash EEPROM Voltage 12 to 30 VDC _ B _ _ _ - 0.00

Combustion Safety
Programming: Primary: Dolphin Plus; Secondary: Handheld programmer Software Single Point Continuous Level _ _ A _ _ - 0.00

and Efficiency
Display: Backlit LCD; Rack/Panel: 3” x 0.8”; Wall Mount: 4” x 1.5” Dual Point Continuous Level _ _ B _ _ - 275.00
Enclosure: Rack Mount: DIN 3U/21HP,4-rail plug-in unit,fits standard 3U/84HP SmartLinx Ready (No Module) _ _ _ 0_ - 0.00
(19”) sub-rack; Panel Mount: Fits DIN 43700 72 x 144 standard panel cutout Data SmartLinx Profibus-DP Module _ _ _ 1_ - 510.00
on 4.33” centers; Wall Mount: Polycarbonate NEMA 4X, IP65 Modules SmartLinx A-B Remotge I/O Module _ _ _ 2_ - 700.00
SmartLinx Devicenet Module _ _ _ 3_ - 510.00
Temperature Compensation: Integral transducer sensor, TS-3 temperature
Protocol Modbus RTU/ASCII Communications _ _ _ _ 1- 0.00
sensor,programmable fixed temperature; Error: 0.09% range; Fixed: 0.17%/°C
deviation from programmed temperature Auxiliary None 0 _ _ _ 0.00
Memory 1 MB Static RAM, Data Logging Module 1 _ _ _ 140.00
Communications: RS232 running Dolphin software, Modbus RTU protocol,
and ASCII. SmartLinx compatible, RS485, RS232 to ECT Tool Kit 2 Analog IN, 2 Analog OUT _ B_ _ 0.00
Auxiliary 4 Analog IN _ C_ _ 110.00
Cable: Signal to be 2 to 3 copper conductors, twisted, with foil shield, drain I/O (With 4 Analog OUT _ D_ _ 110.00
and Communications
Wireless Instruments

wire, 300 V 0.5 to 0.75 mm2 (22 to 18 AWG) RS485 Port) 8 Digital IN _ E_ _ 55.00
Transducers: Echomax® series and ST-H series 8 Digital IN, 2 Analog OUT, 2 Analog IN* _ F_ _ 220.00
Approvals: CSA NRTL/C, CE, and UL Manuals English Instruction Manual _ _ A _ 0.00
Approvals CSA NRTL/C, CE, UL _ _ _ 2 0.00
Accessories Hand Programmer 7ML1830-2AG 100.00
Find more information about Siemens’ EnviroRanger ECT Configuration Toolkit CD PBD-51035226 275.00
ERS500 at www.lesman.com. Additional ECT Software License PBD-51035225 250.00
Need help with your application? See page 441 or ECT Configuration Demo CD PBD-24194462 15.00
download an ERS500 application datasheet. Ships with one user’s manual. * Available on wall mounted models only.
ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
194 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

SITRANS LU Long Range Ultrasonic Level Transmitters


Replaces... Sonic Intelligence™
Field-proven in over 200,000 applications, these patented echo
processing algorithms digitize the sonic echo profile of the vessel
to differentiate between the true echo, reflected from the media
surface, and false echoes generated by bin obstructions and
acoustical or electrical noise.
Flow Measurement

Replaces... It’s artificial intelligence with smarts.


Instruments

To process the raw echo profile reliably in constantly changing and


hostile environments, this advanced software uses curve shaping,
statistical analysis, echo reform, and digital filters to remove electri-
cal interference and narrow echoes.
• It recognizes echo patterns from bin obstructions such as lad-
ders and seams and discounts them.
• It recognizes and ignores the rise time of electrical spikes.
• It recognizes random acoustic reflections from agitator blades
AiRanger SPL For solids
Solids Flow and Motion

and ignores them.


or liquids! • It reconstructs fragmented echoes caused by high air turbulence
The SITRANS LU01 (formerly the AiRanger SPL) system is designed to and broken reflective surfaces to ensure stable measurement
reliably monitor static or dynamically changing level of liquids, slurries, or in hostile conditions.
solids in processes involving high temperatures,harsh chemicals,caustics,
steaming solids, and fine powders in virtually all primary and secondary
industries. Fly ash, sawdust, hot stone, black liquor, plastic pellets, chalk, SITRANS LU models directly to popular industrial buses.You have remote
and carbon black are a few examples of process versatility. two-way access to all instrument data required for improved productivity
The LU01 monitors bulk solids and liquid level in a single vessel ranging without additional wiring,maintenance,and support costs.The SmartLinx
in height from 1 to 200 feet. It uses the same advanced echo process- module can be ordered with the unit today or field installed later, so you
ing techniques and transducer design that made Siemens the leader in have complete flexibility to build the industrial communications network
continuous, noncontacting ultrasonic technology. you need now or in the future.
Rotary and Electric

Temperature sensors, built into the Echomax® transducers or mounted Peripheral Communications Options: With a BIC II communications
Actuator Motors

separately automatically com­pen­sate for changes in sound velocity converter, all measured data from the SITRANS LU systems can be sent
caused by temperature changes.The SITRANS LU02 (AiRanger DPL Plus) to a host computer, PLC or DCS equipped with an RS232 or RS422 port
combines the economy of a single-point unit with the flexibility that using Modbus ASCII protocol.
comes with a multi-frequency capability. One monitor to scan liquids, Faster Scanning, Faster Monitoring: Data — processed up to 10
solids or both, in any two bins of differing size, shape, and configuration. times faster than conventional systems — is continuously displayed in
The electronics are so powerful it is possible to place the unit up to 1200 both numeric and icon formats on an easy-to-read LCD.
feet from its transducers.
• A bargraph shows rapidly changing levels at a glance.
Easy Setup and Operation • Two icons indicate if the vessel is filling or emptying.
The SITRANS LU02 is shipped from the factory pre-calibrated for typical • The point number being scanned is visually displayed.
liquid and solid applications without the need for detailed setup. Select
• Arrows flash when two-way communication is underway (BIC II).
Combustion Safety

a single parameter to switch between liquid and solid materials, enter


and Efficiency

the bin dimensions and the control unit is up and running. Echomax Transducers: Utterly reliable.Models available to meet wide
temperature range requirements. Lower cost of ownership. Echomax
Simplified Programming transducers are immune to most chemicals and can be installed in the
Fine -tuning for your process is simplified with Quick Start parameters. vessel, eliminating the need for elaborate and expensive mounting ar-
You can program to display either level, space, distance, or volume in rangements. In most cases, the integral temperature sensor eliminates
the engineering unit of your choice. Just one entry adjusts the tracking the need and cost of a discrete sensor. Echomax transducers can be con-
speed for changing material levels in any bin. You can view program nected using only shielded, twisted pair, or coaxial cable, substantially
values during setup and operation, so you don’t have to shut down the reducing wiring costs.
process or switch between different display modes to interrogate it. Four Alarm/Control Relays: SPDT relay contact reduces (or eliminates)
Level, temperature, and mA output values can all be selected through external relay logic required. Each relay can be programmed indepen-
and Communications

the keypad.The programmer communicates with the electronics through dently, with alarm and control functions assigned exactly as you need.
Wireless Instruments

a non-invasive infrared interface. Independent alarm ON and OFF setpoints for level, temperature, and
rate of change alarms provide maximum flexibility. A fixed 2% hysteresis
Streamlined Communications Solutions automatically prevents relay chatter for IN or OUT of Bounds alarms.
You can use the handheld programmer for infrared communication Single mA Output: The scalable mA output easily adjusts to suit ap-
with the electronics, or configure and diagnose the instrument remotely plication and controls,reducing external control equipment required.The
with Siemens’ Windows®-based Dolphin Plus software and a laptop or SPL’s single mA output can be programmed for 0-20 or 4-20 mA directly
standard PC. or inversely proportional, and independently scalable to level, space, dis-
Built-in Digital Communications Capability. . .with a Difference: tance, or volume. You won’t need to buy additional equipment to invert
Siemens’plug-in SmartLinx™ interface modules make it simple to link the or convert the output to work with other system components.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 195

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Specifications
Range (Level): From 1 ft. to 200 ft. max. Outputs
Accuracy: 0.25% of target range subject to application. Single mA Output: 0-20 or 4-20 mA,
Resolution: Greater of 0.1% of target range or 0.08”. scalable 0.1% resolution 350Ω max.
load (common ground) or 750Ω max.
Memory: EEPROM (non-volatile). No backup battery required. load (floating common) or 600Ω iso-
Programming: Removable magnetic base programmer commun­icating lated (LIS-1 required).

Flow Measurement
through an infrared interface or Dolphin interface. Relays: Four alarm/control relays;one form
C SPDT contact per relay, rated 5A at 250

Instruments
Display
VAC, non-inductive.
Panel: Graphic 2” x 5” LCD for measurement readings and operating status.
(two numeric displays and icons). Physical Description
Measurement Reading: Level, space or distance in cm, mm, ft., in., %, or any Enclosure: Type 4X/NEMA 4X/IP65 polycar-
other units as programmed. Volume in desired units. bonate enclosure. 11.2”W x 8.2”H x 3.6”D.
Operating Status: Level bargraph,alarm,data communication,filling/empty- Approval: CE, CSA (NRTL/C)
ing, temperature, rate of change, etc. Compatible Transducers: Echomax®: XPS 10,15, 30, 40; XCT 8, 12; XLS 30,
Temperature 60; XLT 30, 60; Ultrason®: STH
Cable: Transducer: RG-62U Coax­ial for extensions to 1,200 ft. Run in grounded

Solids Flow and Motion


Ambient Temperature: -5° to 122°F
metal conduit, separate from other wiring. TS-3: Belden 8760 2 wire
Compensation: -58° to 302°F. Integral sensor in Echomax® transducers shielded/twisted, 18 AWG or equivalent, good to 1,200 ft.
compensates for temp­erature-induced sound velocity variation.
Programmer: Power: 9V (ANSI/NEDA 1604, PP3 or equivalent); Keypad: 20
Temperature Error: 0.09% of range with compensation. 0.31% per °F devia- keys, tactile feedback; Interface: Non-invasive, infrared.
tion from programmed temperature.

A complete level transmitter system includes: Ordering Instructions


1. Transceiver Make one selection from each table below. A complete catalog number looks like this:
2. Transducer (see pages 198 and 199) 7ML5004 - _ _ _ _ _ - 1AA
3. Additional cable lengths
4. Handheld programmer/calibrator Please issue all orders to: Siemens,
Model Selection Guide

Rotary and Electric


5. Optional flanges, as necessary c/o Lesman Instrument Company.

Actuator Motors
6. Aiming kits, software, and communications, as Catalog
necessary Description Number Price
SITRANS LU Long Range Ultrasonic Level Transceivers 7ML5004 - $1600.00
Need help choosing the right Version LU01, Single Point 1 _ _ _ _ - 0.00
level system for your application? LU02, Dual Point 2_ _ _ _ - 200.00
Complete an application datasheet and fax it to Lesman. Input Voltage AC, Voltage Selector Switch _A_ _ _ - 0.00
We’ll have an engineer review your process and specify the Software Standard Feature Software _ _ A _ _- 0.00
best instrument fit to meet your needs. See page 438 or visit Standard Application Software _ _ _ 1 _ - 0.00
our website for a copy of the datasheet. SmartLinx Ready (No Module) _ _ _ _ 0 - 0.00
Data SmartLinx A-B Remote I/O Module _ _ _ _ 1 - 700.00
Communi- SmartLinx Profibus-DP Module _ _ _ _ 2 - 510.00

Combustion Safety
cations SmartLinx Modbus-RTU Module _ _ _ _ 3 - 510.00

and Efficiency
SmartLinx Devicenet Module _ _ _ _ 4 - 510.00
SmartLinx Modem Module _ _ _ _ 6- 510.00
Enclosure Standard - 1_ _ 0.00
Documentation English Instruction Manual - _ A _ 0.00
Approvals CSA NRTL/C, FM - _ _ A 0.00
Handheld Programmer 7ML1830-2AN 100.00
LU01 Main Mother Card, Comms-Ready PBD-51034706 1210.00
Accessories LU01 Daughter Card, Comms-Ready PBD-51033907 970.00
LU02 Main Mother Card, Comms-Ready PBD-51034443 1250.00
LU02 Daughter Card, Comms-Ready PBD-51033908 970.00
and Communications
Wireless Instruments

Display Card PBD-51033909 275.00


Additional SITRANS LU01 7ML1998-1BE01 13.30
Manuals SITRANS LU02 7ML1998-1BD01 25.00
For Echomax ultrasonic transducers compatible with Smartlinx Allen-Bradley Remote I/O 7ML1998-1AP03 15.00
the SITRANS LU series,turn to pages 198 and 199. Smartlinx Profibus DP 7ML1998-1AQ03 10.00

SITRANS LU01, AC Power, Standard SITRANS LU02, AC Power, Stan­dard


Feature Software, SmartLinx Ready Feature Software, SmartLinx Ready
7ML5004-1AA10-1AA....................... $1600.00 7ML5004-2AA10-1AA....................... $1800.00
ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
196 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Multichannel Ultrasonic Level Transmitter


AiRanger XPL

Streamlined Peripheral
Communications Options
Integration of the LU10 into your plant
Flow Measurement

control system is simple. When an analog


Instruments

output is needed for control or display,


the SITRANS LU AO,with ten 0–20 or 4–20
Replaces... mA current outputs can be remotely
mounted up to 5,000 feet from the XPL
unit. For hardwired alarms, the SITRANS
LU SAM provides twenty high and low alarm contacts.
You can double the capacity by adding a second unit. High and low
alarm assignments are flex­ible, so you can set three or four in an active
bin or a single alarm in a vessel. Both the LU AO and LU SAM are set up
through the removable programmer on the SITRANS LU10.
Solids Flow and Motion

Noncontacting Ultrasonic Transducers


• Temperatures as high as 300° F.
We’ll go to any length to measure up! Ranges from 12” to 200 feet.
With the introduction of the SITRANS LU10 (formerly the AiRanger XPL
• Faces and flanges for acids, corrosives, and sanitary use.
Plus), control and measurement efficiency in multiple tank applications
have been taken to new levels of performance. Their reliability has been • Maintenance-free unit with self-cleaning radiating surface.
field-proven in extremely high temperatures, as well as steamy, dusty, and • Totally enclosed, no moving parts.
corrosive environments. Acids, caustics, and fine powders are just a few
examples of difficult applications where these systems have the edge. • No bin-top electronics required.
If your processes demand reliable level measurement data in 1 to 10 • Approvals for hazardous areas.
vessels of any shape or size, in any liquid or bulk solid, and in any environ-
See
• Large echo-capture area. Pages
Rotary and Electric

ment, a single SITRANS LU10 has the flexibility to get the job done.
Actuator Motors

Noncontacting ultrasonic transduc-


198 and
Easy Setup and Operation ers provide safe,efficient meas­ure­ment
199!
The SITRANS LU10 is shipped from the factory pre-calibrated for typical of levels from a few inches to 200 feet,
liquid and solid applications without the need for detailed setup. Select on materials ranging from corrosive
a single parameter to switch between liquid and solid materials, enter liquids to dry bulk solids. EchoMax
the bin dimensions and the control unit is up and running. transducers enable the SITRANS
Fine-tuning for your process is simplified with Quick Start parameters. LU10 transmitter system to operate
You can program to display either level, space, distance, or volume in effectively, even in the presence of dust, steam, bin obstructions, and
the engineering unit of your choice. Just one entry adjusts the tracking environmental noise.
speed for changing material levels in any bin. You can view program
values during setup and operation, so you don’t have to shut down the The Long Shot XLS/XLT Series: These rugged, aluminum transducers
Combustion Safety

process or switch between different display modes to interrogate it. have the range for deep, narrow bins up to 200 feet. In liquids or bulk
and Efficiency

Level, temperature, and mA output values can all be selected through solids, from boiler condensate, to hot tar, they deliver reliability at a
the keypad.The programmer communicates with the electronics through cost per point that makes them the obvious choice. With increased
a non-invasive infrared interface. signal sensitivity and a maximum operating pressure of 120 PSI, you
are in control in difficult applications. A beam angle of 5º makes aim-
Command and Control ing in processes with steep angles of repose less critical for reliable
From the factory to the front office, you can use your laptop computer monitoring. All models have a sealed aluminum face to withstand
for setup and operation with Siemens’software and patented two-way IR noisy, abusive environments.
— without opening the box or making electrical connections.Parameters Hermetically Sealed XPS and XCT Series: XPS and XCT units are encapsulated
can be viewed, altered, uploaded to the LU10, or downloaded to disk. with chemically resistant Kynar® and hermetically sealed so they can be
The BIC II communications converter provides the same link to a host immersed, are resistant to steam, and, without glued joints, withstand at-
and Communications

tack by harsh chemicals. Compact transducers are easily installed without


Wireless Instruments

computer, PLC, or control system for both control units.


flange mounting.
Faster Scanning, Faster Monitoring The Sure Shot XPS Series: Effective to 130 feet, as diverse as bauxite slurry
Supported by an internal 16 bit, 16.7 MHz processor, these transceivers and liquid sulfur, four versatile models have excellent chemical immunity
now process and display data up to 10 times faster than conventional and require reduced aiming. For high-dust applications, XPS per­formance
systems. All the information you need, in numeric and icon formats, is is increased with water-resistant, closed-cell poly­propylene foam facing.
displayed continuously on the easy-to-read display: a bargraph displays XCT Series: For extremely hot, corrosive environments, the XCT series are ef-
liquid and solid levels at a glance; two icons indicate if the bin is filling or fective in food and chemical applications where contamination is a major
emptying; the point number being scanned is displayed visually; arrows concern. They are food-safe, noncontacting, and immune to most acids,
indicate when two-way communication is active. alkalies, and solvents, with a range to 40 feet.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 197

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Specifications A complete level system includes:
Need help finding the right
Power: 100/115/200/230 VAC ±15%, jumper 1. Transceiver level system for your process?
selective; 50/60Hz, 15VA. 2. Transducer (see pages 198 and 199)
Copy the level application datasheet from
Channels: Max. 10 active channels per LU10 unit. 3. Additional cable lengths
page 438. Fill it out and fax it to Lesman.
4. Handheld programmer/calibrator We’ll have an engineer review your process
Range: 1 to 200 feet, depending on transducer.
5. Additional electronic modules and specify the best Siemens system to
Span: 196 ft max., 2” min.
6. Optional flanges and aiming kits as needed meet your needs.

Flow Measurement
Accuracy: Greater of 0.25% range or 0.24”; Reso- 7. Software and communications as needed
lution: Greater of 0.1% range or 0.08”.

Instruments
Temperatures: Operating: -5° to 140°F; Electron-
ics: -5° to 122°F; Process: -40° to 300°F
Ordering Instructions
Temperature Compensation: Common temp Make one selection from each table section below. A complete catalog number looks like this:
sensor input; Option T1B-10 temp sensor input 7ML5007 - _ _ _ _ _ - 1A
board to provide independent compensation
per channel. Please submit orders to: Siemens, c/o Lesman
Volume Conversion: User-selected units for 8 Model Selection Guide Instrument Company.
common tank shapes. Catalog
Display: 2” x 5” graphic LCD. Two 4-digit 0.7” Description Number Price

Solids Flow and Motion


numeric displays. SITRANS LU10 Long-Range Ultrasonic Level Transceiver Electronics 7ML5007 - $4480.00
Programmer: Removable, non-intrusive infrared Input Voltage AC, Voltage Selector Switch 1_ _ _ _ - 0.00
programmer with magnetic retainer, general Software Standard Feature Software _ A _ _ _- 0.00
purpose ABS plastic enclosure. Standard Application Software _ _ A _ _ - 0.00
Enclosure: NEMA 4X polycarbonate, stainless SmartLinx Ready (No Module) _ _ _ 0 _ - 0.00
steel screws; Optional NEMA 7 cast aluminum Data SmartLinx A-B Remote I/O Module _ _ _ 1 _ - 700.00
Communications SmartLinx Profibus-DP Module _ _ _ 2 _ - 510.00
Cable: For extensions to 333 ft. total, use 18 AWG
SmartLinx Modbus-RTU Module _ _ _ 3 _ - 510.00
shielded twisted pair cable. For extensions to SmartLinx Devicenet Module _ _ _ 4 _ - 510.00
1,200 feet max., use RG-62 A/U coaxial cable. SmartLinx Modem Module _ _ _ 6 _ - 510.00
Transducer Drive: 44 kHz, 315V peak pulses Temperature None _ _ _ _ 0 - 0.00
of max. 1 mSec duration typical; 22 kHz, 150V Option Standard (TIB9) _ _ _ _ 1 - 217.00
peak pulses of max. 1.7 mSec. duration typical;
Enclosure Standard - 1_ 0.00

Rotary and Electric


or 13 kHz, 150V peak pulses of max 1.7 mSec.

Actuator Motors
duration typical; Max. repetition rate: 200 Approvals CE, CSA, FM - _ A 0.00
mSec/transmit. SITRANS LU SAM: 20 Relay Output Alarm Module 7ML5811-1A 1530.00
Analog Output: Programming only, no on- SITRANS LU AO: 10 Output Module 7ML5810-1A 1150.00
board output. Optional modules. Handheld Programmer 7ML1830-2AN 100.00
TIB-9 Temperature Card 7ML1830-1CN 240.00
Data Link: Transmit only; Single ±20 mA bi-polar Accessories Communications Ready Main Mother Card PBD-51034734 3415.00
current loop @ 4800 baud. 10,000 feet max Communications Ready Daughter Card PBD-51034437 1810.00
loop. Loading: 3 peripheral devices max. Display Card PBD-51033419 275.00
Relay Outputs: Programming only, no on-board SITRANS LU10 Instruction Manual 7ML1998-5AN02 20.00
relays. Optional SAM-20 satellite alarm module. SITRANS LU SAM Instruction Manual 7ML1998-5CF02 10.00
SITRANS LU AO Instruction Manual 7ML1998-5CE01 10.00
Analog and Relay Output Modules Additional SmartLinx Allen-Bradley Remote I/O Instruction Manual 7ML1998-1AP03 15.00

Combustion Safety
AO-10 Output: 10 analog outputs.Isolated 0–20 or Instruction SmartLinx Profibus DP Instruction Manual 7ML1998-1AQ03 10.00

and Efficiency
4–20 mA into 750Ω max., 0.1% resolution. Manuals SmartLinx Devicenet Instruction Manual 7ML1998-1BH02 10.00
SmartLinx Modbus Instruction Manual 7ML1998-1BF01 10.00
SAM-20 Output: 20 multipurpose relays. One SmartLinx Modem Instruction Manual 7ML1998-1BG01 10.00
Form C SPDT contact per relay, rated 5A @ 220
VAC non-inductive. Communication output
±20 mA bi-polar current loop (input retrans­
mission), 1 receiving unit max. load. 304 SS
Power: 100/115/200/230 VAC ±15%. Easy Ordering Instructions
Aimer Make one selection from each table below. A complete catalog number looks
Input: Data link communications from AiRanger like this: 7ML1830 - _ _ _
XPL Plus. ±20 mA bipolar current loop, 4800
baud rate, non-polarized.
Model Selection Guide
and Communications
Wireless Instruments

Display: 1 power/comms status LED; 20 relay


status LEDs (SAM-20). Catalog
Description Number Price
Memory: 10 minutes minimum data retention.
Easy Aimer: Aim Transducers for Optimal Performance 7ML1830 - $0.00
Operating Temperature: -5° to 140°F Aluminum, NPT with 1.5” Galvanized Coupling* 1AN 95.00
Enclosure (HWD): Standard open polycarbonate Aluminum, NPT with 1” Galvanized Coupling 1AP 95.00
board (7.6” x 10.2” x 2.3”); Optional NEMA 4X Aluminum, NPT with 3/4” x 1” PVC Coupling 1AQ 95.00
polycarbonate board (8.2” x 11.2” x 3.6”). 304SS, NPT with 1.5” Coupling* 1AT 415.00
304SS, NPT with 1” Coupling 1AU 415.00
Interconnection Cable: Belden 8760, 1 pair
shielded/twisted, 18 GA. * For use with XPS-30 or XPS-40 transducers only.
ULTRASONIC Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
198 TRANSDUCERS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Echomax Ultrasonic Level Transducers Please submit orders to: Siemens, c/o Lesman
Instrument Company

Transducers Compatible with All Siemens Continuous Ultrasonic Transmitter Systems


Beam Measuring Temperature Flange Cable Catalog
Angle Distance Range Type Series Length Number Price
For Wet Applications: Blue Kynar Housing and Aluminum Sensor Face. ATEX and FM Approvals. 1” NPT Mounting Thread.
6° 1 to 50 Ft -40 to 203°F XPS-15 5M 7ML1118-0BA30 $640.00
6° 1 to 50 Ft -40 to 203°F XPS-15 10M 7ML1118-0CA30 665.00
6° 1 to 50 Ft -40 to 203°F XPS-15 30M 7ML1118-0EA30 695.00
Flow Measurement

6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15-6 5M 7ML1118-0BD30 885.00


6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15-6 10M 7ML1118-0CD30 910.00
Instruments

Features 6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15-6 30M 7ML1118-0ED30 940.00


• Two-way dynamic im- 6° 1 to 50 Ft -40 to 203°F 8” CPVC Flange XPS-15-8 5M 7ML1118-0BE30 940.00
6° 1 to 50 Ft -40 to 203°F 8” CPVC Flange XPS-15-8 10M 7ML1118-0CE30 965.00
pedance matching pro- 6° 1 to 50 Ft -40 to 203°F 8” CPVC Flange XPS-15-8 30M 7ML1118-0EE30 995.00
vides high output and 12° 1 to 33 Ft -40 to 203°F XPS-10 5M 7ML1115-0BA30 455.00
sensitive echo capture 12° 1 to 33 Ft -40 to 203°F XPS-10 10M 7ML1115-0CA30 480.00
• Unique unidriver con- 12° 1 to 33 Ft -40 to 203°F XPS-10 30M 7ML1115-0EA30 570.00
struction gives highest 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10-3 5M 7ML1115-0BC30 575.00
temperature operation 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10-3 10M 7ML1115-0CC30 580.00
12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10-3 30M 7ML1115-0EC30 630.00
available in any ultrason- 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10-4 5M 7ML1115-0BD30 600.00
Solids Flow and Motion

ic system: 150º C (300º F) 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10-4 10M 7ML1115-0CD30 625.00
• Uniformity as close 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10-4 30M 7ML1115-0ED30 655.00
as 1 foot, so you can 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10-6 5M 7ML1115-0BE30 695.00
depend on short-range 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10-6 10M 7ML1115-0CE30 720.00
reliability 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10-6 30M 7ML1115-0EE30 750.00
For Corrosive and Wet Applications: Blue Kynar Housing, Teflon-Coated Aluminum Sensor Face. ATEX and FM Approvals.
• Reliable in liquids and
solids from 1 to 200 feet 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10T-3 5M 7ML1115-2BC30 660.00
12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10T-3 10M 7ML1115-2CC30 685.00
• No moving parts to 12° 1 to 33 Ft -40 to 203°F 3” CPVC Flange XPS-10T-3 30M 7ML1115-2EC30 715.00
cause downtime 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10T-4 5M 7ML1115-2BD30 685.00
• Simple, economical 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10T-4 10M 7ML1115-2CD30 710.00
installation 12° 1 to 33 Ft -40 to 203°F 4” CPVC Flange XPS-10T-4 30M 7ML1115-2ED30 740.00
12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10T-6 5M 7ML1115-2BE30 780.00
• Mounting location is
Rotary and Electric

12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10T-6 10M 7ML1115-2CE30 805.00


Actuator Motors

more flexible, so ob- 12° 1 to 33 Ft -40 to 203°F 6” CPVC Flange XPS-10T-6 30M 7ML1115-2EE30 835.00
stacles can be avoided 6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15T-6 5M 7ML1118-2BD30 970.00
6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15T-6 10M 7ML1118-2CD30 995.00
• Chemically resistant 6° 1 to 50 Ft -40 to 203°F 6” CPVC Flange XPS-15T-6 30M 7ML1118-2ED30 1025.00
• Hermetically sealed 6° 1 to 50 Ft -40 to 203°F 8” CPVC Flange XPS-15T-8 5M 7ML1118-2BE30 1025.00
models immune to dust, 6° 1 to 50 Ft -40 to 203°F 8” CPVC Flange XPS-15T-8 10M 7ML1118-2CE30 1050.00
steam, turbulence, cor- 6° 1 to 50 Ft -40 to 203°F 8” CPVC Flange XPS-15T-8 30M 7ML1118-2EE30 1080.00
rosives For Dusty or Corrosive Applications: Blue Kynar Housing, Aluminum Sensor Face, Foam Facing. CSA and FM Approvals.
• Aiming is less critical 12° 1 to 33 Ft -40 to 203°F 1” NPT Mounting Thread XPS-10P 1M 7ML1115-1AA31 497.00
12° 1 to 33 Ft -40 to 203°F 1” NPT Mounting Thread XPS-10P 10M 7ML1115-1CA31 517.00
• 1” NPT conduit connec- 12° 1 to 33 Ft -40 to 203°F 1” NPT Mounting Thread XPS-10P 30M 7ML1115-1EA31 547.00
tion with NEMA 4 ingress 6° 1 to 50 Ft -40 to 203°F 1” NPT Mounting Thread XPS-15P 1M 7ML1118-1AA31 678.00
Combustion Safety

protection (except XRS-5, 6° 1 to 50 Ft -40 to 203°F 1” NPT Mounting Thread XPS-15P 10M 7ML1118-1CA31 698.00
and Efficiency

which has IP-68 rating) 6° 1 to 50 Ft -40 to 203°F 1” NPT Mounting Thread XPS-15P 30M 7ML1118-1EA31 721.00
• Models available with For Hazardous Environments: Blue Kynar Housing, Aluminum Sensor Face. FM (Class 1, Division 1) Approval.
CSA, FM, CE, 3A, and FDA 1” NPT Mounting Thread.
approvals 12° 1 to 33 Ft -40 to 203°F XPS-10F 5M 7ML1170-1BA10 555.00
12° 1 to 33 Ft -40 to 203°F XPS-10F 10M 7ML1170-1CA10 580.00
12° 1 to 33 Ft -40 to 203°F 3” ANSI Flange XPS-10F-3 5M 7ML1170-1BB10 675.00
12° 1 to 33 Ft -40 to 203°F 3” ANSI Flange XPS-10F-3 10M 7ML1170-1CB10 700.00
12° 1 to 33 Ft -40 to 203°F 4” ANSI Flange XPS-10F-4 5M 7ML1170-1BC10 700.00
12° 1 to 33 Ft -40 to 203°F 4” ANSI Flange XPS-10F-4 10M 7ML1170-1CC10 725.00
12° 1 to 33 Ft -40 to 203°F 6” ANSI Flange XPS-10F-6 5M 7ML1170-1BD10 795.00
12° 1 to 33 Ft -40 to 203°F 6” ANSI Flange XPS-10F-6 10M 7ML1170-1CD10 820.00
and Communications
Wireless Instruments

12° 1 to 33 Ft -40 to 203°F 8” ANSI Flange XPS-10F-8 5M 7ML1170-1BE10 850.00


12° 1 to 33 Ft -40 to 203°F 8” ANSI Flange XPS-10F-8 10M 7ML1170-1CE10 875.00
6° 1 to 50 Ft -40 to 203°F XPS-15F 5M 7ML1171-1BA10 745.00
6° 1 to 50 Ft -40 to 203°F XPS-15F 10M 7ML1171-1CA10 770.00
6° 1 to 50 Ft -40 to 203°F XPS-15F 30M 7ML1171-1DA10 800.00
6° 1 to 50 Ft -40 to 203°F 6” ANSI Flange XPS-15F-6 5M 7ML1171-1BB10 990.00
6° 1 to 50 Ft -40 to 203°F 6” ANSI Flange XPS-15F-6 10M 7ML1171-1CB10 1015.00
6° 1 to 50 Ft -40 to 203°F 6” ANSI Flange XPS-15F-6 30M 7ML1171-1DB10 1045.00
6° 1 to 50 Ft -40 to 203°F 8” ANSI Flange XPS-15F-8 5M 7ML1171-1BC10 1045.00
Echomax 6° 1 to 50 Ft -40 to 203°F 8” ANSI Flange XPS-15F-8 10M 7ML1171-1CC10 1070.00
6° 1 to 50 Ft -40 to 203°F 8” ANSI Flange XPS-15F-8 30M 7ML1171-1DC10 1100.00
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TRANSDUCERS 199

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Transducers Compatible with All Siemens Continuous Ultrasonic Transmitter Systems
Beam Measuring Temperature Flange Type Cable Catalog
Angle Distance Range ANSI 150# Series Length Number Price XRS-5
For Caustic Liquids and Slurries: Polypropylene Housing, Hypalon Rubber Sensor Face. CE, CSA, FM, ATEX Approvals.
1” NPT Mounting Thread. Teflon Facing Available on Flanged Models— Call Lesman.
10° 1 to 16.5 Ft -4 to 149°F XRS-5 5M 7ML1106-1AA20-0A $365.00
10° 1 to 16.5 Ft -4 to 149°F XRS-5 10M 7ML1106-1BA20-0A 390.00

Flow Measurement
10° 1 to 16.5 Ft -4 to 149°F XRS-5 30M 7ML1106-1CA20-0A 420.00
10° 1 to 16.5 Ft -4 to 149°F 3” ANSI Flange XRS-3 5M 7ML1106-1AA20-0B 485.00

Instruments
10° 1 to 16.5 Ft -4 to 149°F 3” ANSI Flange XRS-3 10M 7ML1106-1BA20-0B 510.00
10° 1 to 16.5 Ft -4 to 149°F 3” ANSI Flange XRS-3 30M 7ML1106-1CA20-0B 540.00
• Built-in temperature
10° 1 to 16.5 Ft -4 to 149°F 4” ANSI Flange XRS-4 5M 7ML1106-1AA20-0C 510.00 compensation automa­
10° 1 to 16.5 Ft -4 to 149°F 4” ANSI Flange XRS-4 10M 7ML1106-1BA20-0C 535.00 tically adjusts for velocity
10° 1 to 16.5 Ft -4 to 149°F 4” ANSI Flange XRS-4 30M 7ML1106-1CA20-0C 565.00 variations caused by air
10° 1 to 16.5 Ft -4 to 149°F 6” ANSI Flange XRS-6 5M 7ML1106-1AA20-0D 605.00 temperature changes in
10° 1 to 16.5 Ft -4 to 149°F 6” ANSI Flange XRS-6 10M 7ML1106-1BA20-0D 630.00 the vessel, ensuring opti-
10° 1 to 16.5 Ft -4 to 149°F 6” ANSI Flange XRS-6 30M 7ML1106-1CA20-0D 660.00 mum accuracy from ‑4º to
For High Temperature Corrosive and Wet Applications: White Kynar Housing, Aluminum Sensor Face. ATEX, FM, CENELEC, and 149º F (‑20° to 65º C)
FDA Food-Grade Approvals. 1” NPT Mounting Thread. • Narrow beam pattern

Solids Flow and Motion


12° 1 to 26 Ft -40 to 293°F XCT-8 1M 7ML1132-0AA40 620.00 with negligible side lobes
12° 1 to 26 Ft -40 to 293°F XCT-8 10M 7ML1132-0CA40 705.00 gives reliable performance
12° 1 to 26 Ft -40 to 293°F XCT-8 30M 7ML1132-0EA40 870.00 over full temperature
6° 1 to 40 Ft -40 to 293°F XCT-12 1M 7ML1136-0AA30 790.00
6° 1 to 40 Ft -40 to 293°F XCT-12 10M 7ML1136-0CA30 875.00
range, even in narrow
6° 1 to 40 Ft -40 to 293°F XCT-12 30M 7ML1136-0EA30 1040.00 tanks.
For FM Class I, Div 1 Liquid and Solid Applications, including Hazardous, Corrosive and Wastewater Environments. Tefzel Base • Low ringing cuts
and Lid Epoxy Fitted Joint). CE, CSA, CENELEC Approvals. blanking distance to a
12° 1 to 33 Ft -40 to 164°F 2” NPT Mounting Thread ST-H 5M 7ML1100-0AA20 525.00 minimum, so you can use
12° 1 to 33 Ft -40 to 164°F 2” NPT Mounting Thread ST-H 10M 7ML1100-0BA20 550.00 the full tank capacity and
12° 1 to 33 Ft -40 to 164°F 2” NPT Mounting Thread ST-H 30M 7ML1100-0CA20 580.00 eliminate the need for tall
standpipes
• Closed cell foam is im-

Rotary and Electric


Transducers Compatible Only with Siemens LU (AiRanger) Series Ultrasonic Transmitters mune to moisture and

Actuator Motors
temperature-independent
Beam Measuring Temperature Cable Catalog
Angle Distance Range Flange Type Series Length Number Price • High sensitivity across
For Wet Applications: Blue Kynar Housing, Aluminum Sensor Face. CSA, FM Approvals. 1-1/2” NPT Mounting Thread. the transducer face
improves performance
6° 2 to 100 Ft -40 to 203°F XPS-30 5M 7ML1123-0BA50 $935.00
6° 2 to 100 Ft -40 to 203°F XPS-30 10M 7ML1123-0CA50 960.00
on solids and is especially
6° 2 to 100 Ft -40 to 203°F XPS-30 30M 7ML1123-0EA50 990.00 effective for long shots up
6° 2 to 100 Ft -40 to 203°F 6” CPVC Flange XPS-30-6 5M 7ML1123-0BD50 1180.00 to 200 feet
6° 2 to 100 Ft -40 to 203°F 6” CPVC Flange XPS-30-6 10M 7ML1123-0CD50 1205.00 • Self-cleaning, low main-
6° 2 to 100 Ft -40 to 203°F 6” CPVC Flange XPS-30-6 30M 7ML1123-0ED50 1235.00 tenance. Condensa­tion,
6° 2 to 100 Ft -40 to 203°F 8” CPVC Flange XPS-30-8 5M 7ML1123-0BE50 1235.00 liquid, and dust won’t
6° 2 to 100 Ft -40 to 203°F 8” CPVC Flange XPS-30-8 10M 7ML1123-0CE50 1260.00
build up on the active

Combustion Safety
6° 2 to 100 Ft -40 to 203°F 8” CPVC Flange XPS-30-8 30M 7ML1123-0EE50 1290.00
transducer face

and Efficiency
6° 2 to 300 Ft -40 to 203°F XPS-40 5M 7ML1127-0BA50 1040.00
For Corrosive and Wet Applications: Blue Kynar Housing, Aluminum Sensor Face. ATEX, FM Approvals.
6° 2 to 100 Ft -40 to 203°F 6” CPVC Flange XPS-30T-6 5M 7ML1123-2BD50 1350.00
6° 2 to 100 Ft -40 to 203°F 6” CPVC Flange XPS-30T-6 10M 7ML1123-2CD50 1375.00
6° 2 to 100 Ft -40 to 203°F 6” CPVC Flange XPS-30T-6 30M 7ML1123-2ED50 1405.00
6° 2 to 100 Ft -40 to 203°F 8” CPVC Flange XPS-30T-8 5M 7ML1123-2BE50 1405.00
6° 2 to 100 Ft -40 to 203°F 8” CPVC Flange XPS-30T-8 10M 7ML1123-2CE50 1430.00
6° 2 to 100 Ft -40 to 203°F 8” CPVC Flange XPS-30T-8 30M 7ML1123-2EE50 1460.00
For Dusty or Corrosive Applications: Blue Kynar Housing, Aluminum Sensor Face and Foam Facing. CSA, FM Approvals.
6° 2 to 100 Ft -40 to 203°F 1-1/2” NPT Mtg. Thread XPS-30P 5M 7ML1123-1BA50 1020.00
6° 2 to 100 Ft -40 to 203°F 1-1/2” NPT Mtg. Thread XPS-30P 10M 7ML1123-1CA50 1045.00
and Communications
Wireless Instruments

6° 2 to 100 Ft -40 to 203°F 1-1/2” NPT Mtg. Thread XPS-30P 30M 7ML1123-1EA50 1075.00
6° 2 to 130 Ft -40 to 203°F 1-1/2” NPT Mtg. Thread XPS-40P 5M 7ML1127-1BA50 1210.00

Need an aiming kit or field mounting hardware


for your level sensor? See page 197.
We’ve got all you need.
See page 200 for field mounting kits.
MOUNTING Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
200 BRACKETS Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Mounting Brackets for Ultrasonic Sensors


Features Compatible With
• Rugged, stainless steel suitable for indoor and outdoor use Probe (FMS-200 Only) ULS200 (FMS-200 Only)
• Saves time and expense of building custom brackets XPS-15 XPS-10 XPS-15F XPS-10F
• Each kit includes mounting hardware XCT-12 XCT-8 XRS-5 ST-H
Flow Measurement

Echomax mounting
Instruments

FMS-200 Universal Box Bracket Kit Includes Order


Allows any unit with a threaded 1” or 2” connection to be Two 1” mounting nuts 7ML1830-1BK
mounted 8” to 12” out from a wall or beam. The unique One 2” mounting nut $95.00
box design also acts as a sun shield for the transducer.
Solids Flow and Motion

FMS-210 Wall Mount Channel Bracket Kit Includes Order


Allows any transducer with a threaded 1” connection to Four 1/4” lock washers 7ML1830-1BL
be mounted 5” to 19” out from a wall or beam. Two 1” mounting nuts $130.00
Two 2” mounting nuts
Four M6x12 bolts

FMS-220 Extended Channel Bracket Kit Includes Order


Rotary and Electric

7ML1830-1BM
Actuator Motors

Allows any transducer with a threaded 1” connection to Four 1/4” lock washers
be mounted 13” to 39” out from a wall or beam. Two 1” mounting nuts $220.00
Four M6x12 bolts
Two M6x30 bolts

FMS-310 Floor Mount Channel Bracket Kit Includes 7ML1830-1BN


Allows any transducer with a threaded 1” connection Four 1/4” lock washers $210.00
to be mounted from 19” high and from 22” out past the Two 1” mounting nuts
mounting. Four M6x12 bolts
Combustion Safety

One M8x50 bolt


and Efficiency

FMS-320 Floor Mount Extended Channel Kit Includes Order


Bracket Four 1/4” lock washers 7ML1830-1BP
Allows any transducer with a threaded 1” connection to Two 1” mounting nuts $300.00
be mounted from 19” high and from 16” to 43” out past Six M6x12 bolts
the mounting. Two M6x30 bolts
One M8x50 bolt
and Communications
Wireless Instruments

FMS-350 Floor Mount Bridge Channel Bracket Kit Includes Order


Allows any transducer with a threaded 1” connection to Four 1/4” lock washers 7ML1830-1BQ
be mounted from 19” high, anywhere along a 65” beam. Two 1” mounting nuts $500.00
This bracket is well-suited for large OCM applications by Twelve M6x12 bolts
providing a very stable mount for the transducer above Three M6x30 bolts
a flume or weir. Two M8x50 bolts
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan ULTRASONIC

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 201

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
SmartLinx™ Communications Interface Modules
Allen-Bradley
PLC-5/250™

etwork
Makes N on Easy!
icati
Commun

Flow Measurement
Instruments
Allen-Bradley
Remote I/O

SmartLinx modules SmartLinx™ Modem Module Now Available


Features Siemens modem module connects a SmartLinx-compatible device to a

Solids Flow and Motion


• Connects directly to standard Allen-BradleyRemote I/O (blue Modbus RTU/ASCII master device via a standard modem connection and an
hose), Siemens Profibus DP, Devicenet, and Modbus RTU RJ11C plug, at baud rates from 1200 to 14400.
systems. No extra wiring, boxes, or third-party protocols. The modem module is compatible with Modbus RTU/ASCII instru­ments
that use function codes 03, 06, and 16. Like other SmartLinx modules, the
• Plugs directly into any SmartLinx-ready transceiver. modem card can be added, at any time, to a SmartLinx-ready transceiver
• Uses standard PLC data transfer techniques — block in the field.
transfer or discrete I/O — with minimum demand on PLC
resources.
• Provides all status and measurement data from the instru-
ment. And, in block transfer mode, it supports writing of all
appropriate parameters from the connected control unit.

Rotary and Electric


• Can be added later, or switched out for another SmartLinx

Actuator Motors
module — if you change PLC systems or protocols.

With SmartLinx, any Siemens SITRANS LU transceiver can Please issue all orders to: Siemens,
talk to the most popular industrial communication networks c/o Lesman Instrument Company.
— including the Allen-Bradley Remote I/O or Siemens Profi-
Model Selection Guide
bus-DP. Better yet, SmartLinx modules connect compatible Catalog
Description Number Price
Siemens transceivers directly onto the PLC network, so you
don’t have to buy or maintain any intermediary hardware, SmartLinx Modbus RTU Module
software, or wiring. Module for SITRANS LU01/LU02/LU10 7ML1830-1CR $510.00
Instruction Manual 7ML1998-1BF01 10.00
SmartLinx system operation supports both block transfer
SmartLinx for Allen-Bradley Remote I/O Modules
and discrete I/O modes, and permits full read access to all

Combustion Safety
Module for SITRANS LU01/LU02/LU10 7ML1830-1CP 700.00
instrument data. When the SmartLinx SITRANS LU is in block

and Efficiency
Module for Rack and Panel Mount EnviroRanger 7ML1830-1HP 700.00
transfer mode, you can even write modifiable parameters Module for Wall Mount EnviroRanger, Accumass BW500
directly to the transceiver. or SF500, MultiRanger 100/200 or HydroRanger 7ML1830-1HS 700.00
Using SmartLinx,all level readings (up to 10 with the SITRANS Data Disk 7ML1830-1CK 25.00
Instruction Manual 7ML1998-1AP03 15.00
LU10), as well as some status bits and healthy/failed bits are
available to your communication network host. Other param- SmartLinx for Profibus-DP Modules
eters may be read 10 at once, and written one at a time. The Module for SITRANS LU01/LU02/LU10 7ML1830-1CQ 510.00
Module for Rack and Panel Mount EnviroRanger 7ML1830-1CS 510.00
interface works just like the keypad: The host (PLC) writes the
Module for Wall Mount EnviroRanger, Accumass BW500 or
parameter number and point number of the desired parameter, SF 500, MultiRanger 100/200 or HydroRanger 7ML1830-1HR 510.00
and then writes the new parameter value. Data Disk 7ML1830-1CL 25.00
Even if you’re not ready to connect your SITRANS LU to a Instruction Manual 7ML1998-1AQ03 10.00
and Communications
Wireless Instruments

PLC — but you think you might want to in the future — you SmartLinx for DeviceNet Modules
can still buy the SmartLinx-compatible model. When you do Module for SITRANS LU01/LU02/LU10 7ML1830-1CT 510.00
want to connect your LU01, LU02, or LU10 into your network, Module for Rack and Panel Mount EnviroRanger 7ML1830-1HQ 510.00
you can order the SmartLinx module that matches your PLC’s Module for Wall Mount EnviroRanger, Accumass BW500 or
communications protocol. The module slides directly into the SF 500, MultiRanger 100/200 or HydroRanger 7ML1830-1HT 510.00
Data Disk 7ML1830-1CM 25.00
transceiver unit, and can be installed by qualified personnel
Instruction Manual 7ML1998-1BH02 10.00
whenever you’re ready to use it.
SmartLinx Modem Module
Module for SITRANS LU01/LU02/LU10 7ML1830-1HN 510.00
Instruction Manual 7ML1998-1BG01 10.00
RADAR Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
202 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Comparing Siemens Radar Instrumentation

Need Help?
Fill out a radar
level application
datasheet on page
Flow Measurement

440 and fax it


Instruments

to Lesman for an
engineering review.
t Two-wire loop powered
Prices star pulse radars for bulk
at $ 9 9 5 ! liquid chemical storage Long range FM radar
in simple process vessels for difficult and dusty
and tank farms. Probe LR Pulse radar for liquids applications, low
has a plastic enclosure and slurries in tanks dielectric liquids,
— ideal for chemical with agitators, or narrow vessels
applications. LR200 has obstructions and requiring a smaller
Solids Flow and Motion

an aluminum enclosure. healing coils. beam angle.

SITRANS Probe LR/LR200 SITRANS LR300 SITRANS LR400


Range 66 ft. (20m) 66 ft. (20m) 147ft. (20m)
Frequency 6.3 GHz 6.3 GHz 24 GHz FMCW
Dielectric >3 (for <3 use waveguide >3 (for <3 use waveguide >1.6
Constant antenna or stillpipe) antenna or stillpipe)
Accuracy ±the greater of 0.1% range or 10mm ±the greater of 0.15% range or 15mm ≤±15mm at 0.26m to 2m, ≤±5mm
at 2m to 10m, ≤±mm at 10m to 45m
Repeatability ±5mm ±2mm (range <3m), ±3mm (range 5m), ±1mm
Rotary and Electric
Actuator Motors

±5mm (range <10m), ±10mm (range 20m)


Analog 4 to 20 mA ±0.02 mA accuracy Optically isolated 4 to 20 mA into Optically isolated 4 to 20 mA
Output max. 550Ω @ 24 VDC 450Ω max. ±0.02 mA resolution into 600Ω max.
Relay Relay, NCC or NOC function, max.
DC 50V, max. 200 mA, rating 5W
Local Multi-segment alphanumeric liquid crystal Multi-graphic liquid crystal for Alphanumeric liquid crystal
Display with bar graph (representing level) readout and entry for readout and entry
Commun- HART, Infrared handheld programmer HART, Modbus, Profibus PA,
ications SIMATIC PDM Infrared handheld programmer, HART, Profibus PA, SIMATIC PDM
SIMATIC PDM, RS485
Flat-faced flanges: stainless steel, 80, 100,
Process 1.5” NPT, BSP, or G (polypropylene), Flanges, sanitary, threaded 150mm (3, 4, 6”), bolt hole pattern to ANSI,
Combustion Safety

Connections flanges, sanitary DIN and JIS sizes; Stainless Steel Ball/Swivel-
and Efficiency

Type Easy Aimer


Antenna Hermetically sealed polypropylene rod.
Standard: 100mm (4”) shield for max. Rod: Teflon® (PTFE); Other 74mm diameter horn antenna;
100mm (4”) nozzle; Optional: 250mm antenna types available; 93mm diameter horn antenna;
(10”) long shield; Rod: Teflon® (PTFE); Other Purge optional Purge optional
antenna types available; Purge optional
Enclosure Probe LR: PBT polymer, hard-coated polyether Epoxy-coated aluminum or Polyester powder-coated diecast aluminum;
imide lid; Type 4X/NEMA 4X, Type 6/IP68; 316 stainless steel; Ingress protection: Type 4X/NEMA 4X,
LR200: Aluminum, polyester powder-coated; Ingress protection: Type 4X/ Type 6/NEMA 6, IP67
Type 4X/NEMA 4X, NEMA 6, IP67 protection NEMA 4X, Type 6/NEMA 6, IP67
Power 4 to 20 mA loop powered Universal AC/DC power supply
and Communications
Wireless Instruments

Ambient -40° to 176°F (-40° to 80°C) -40° to 140°F (-40° to 60°C) -40° to 140°F (-40° to 65°C)
Temperature
Process -40° to 392°F (-40° to 200°C) process -40° to 392°F (-40° to 200°C) -40° to 392°F (-40° to 200°C);
Temperature connections type dependent -40° to 482°F (-40° to 250°C) optional
Vessel Pressure Up to 40 bar (600 PSI) process connections type dependent
Approvals CE, CSAUS/C, FM, ATEX, CE, CSAUS/C, FM, ATEX, Industry Canada, CE, CSAUS/C, FM, ATEX,
Industry Canada, FCC, R&TTE, 3A FCC, R&TTE, Lloyd’s Register, 3A Industry Canada, FCC, R&TTE, BZT
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan RADAR

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 203

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
SITRANS Probe LR for Bulk Liquid Storage Levels
Features SITRANS Probe LR is a two-wire, loop-powered 6.3GHz radar transmit-
• Uni-construction polypropylene rod ter for level and volume monitoring of liquids and slurries in storage
antenna standard and process vessels. The Probe LR is ideal for applications with chemical
vapors, temperature gradients, vacuum or simple pressure, such as tank
• Easy installation, simple startup — just set farms,chemical storage, digesters, and long-range applications. Probe LR
two parameters and go! was designed for measuring liquid levels in bulk storage vessels, simple
• Programming using intrinsically safe hand- process vessels with gentle agitation, liquids, and slurries.

Flow Measurement
held programmer, Simatic PDM software and SITRANS Probe LR has a range of 1 to 65 feet (0.3 to 20m), and is avail-
a PC, or HART® handheld communicator

Instruments
able in two versions: general purpose (for non-hazardous locations), and
• Patented Sonic Intelligence signal processing intrinsically safe (with suitable IS barrier) for harsher environments.
• Extremely high signal-to-noise ratio — for Probe LR is designed for safe and simple programming,using the intrin-
sically safe hand programmer, without having to open the instrument’s
superior quality echoes, even in turbulent lid.It has a standard uni-construction, hermetically sealed, polyproplyene
and long-range applications rod antenna that offers excellent chemical resistance. It also has a high
• Automatic false-echo suppression algorithm signal-to-noise ratio for improved reliability.
for true tank level readings Startup is easy,with as few as two parameters
• Low noise transmitter and low noise for basic operation. You can make parameter
v e l changes using the hand programmer,a HART®

Solids Flow and Motion


Rad a r le shield — less interference from electri-
handheld communicator, or with a PC and Sie-
for $ 9 9 5 ! cal noise, stronger echo, longer range,
mens Simatic PDM configuration software.
and short blanking distance
The local alphanumeric display is standard
• Make simple configuration changes with the to all Probe LR models. There’s a primary dis-
infrared handheld programmer — no need play showing engineering units or percent of
to open the enclosure, connect wires, or plug level, distance, or volume; a secondary display
in modules for local programming for mA, temperature, signal status, faults, and parameter values, and an
• Rugged, encapsulated design is corrosion, active bargraph to show material level.
vibration, and high impact resistant. An echo status indicator ensures that your echo is reliable. If the echo
confidence drops below the echo confidence threshold, the failsafe timer
• Electronics head rotates for easy wiring and starts running. When the timer expires, a Loss of Echo status shows on
repositioning during installation. the display. When a valid reading is received, the level reading display

Rotary and Electric


Actuator Motors
returns to normal operation.
SITRANS Probe LR The SITRANS Probe LR is the best choice for mounting in metallic
stillpipes and side pipes to measure the levels of clean free-flowing liq-
uids. A pipe bottom deflector can be used on low dK materials to allow
readings at lower levels.
Radar Handles Corrosive Environments
Application: Level monitoring of brine storage tanks. Not sure if the Probe LR is for you?
Problem: Existing transmitting strapping gauge was unreliable Fill out a radar level application datasheet
and maintenance-intensive. on page 440 and fax it to Lesman.
User’s Existing Business Results

Combustion Safety
• Costly Spills: Continuous level measurement is essential on
Ordering Instructions

and Efficiency
brine storage tanks to alert operators of high- or low-level con-
Make one selection from each table section. Completed catalog numbers
ditions, so they can adjust throughput and avoid spills. will look like this: 7ML5430-_ _ _ _0
• Instrumentation Failures: Ultrasonic transmitters were not
able to perform the needed measurements. The output signal Please submit orders to: Siemens,
of a competitor’s radar device wasn’t stable at high level condi- Model Selection Guide c/o Lesman Instrument Company
tions and failed shortly after installation. The corrosive iodine Catalog
destroyed the radar unit’s aluminum enclosure and electronics. Description Number Price
Sitrans Probe LR: PBT Enclosure, 2x0.5” NPT Cable Inlet 7ML5430- $995.00
Business Results After Installation Antenna 1.5” NPT, Integral 100mm Shield 0A _ _ _ 0.00
• SITRANS Probe LR, with its plastic enclosure, was able to stand 1.5” NPT, Integral 250mm Shield 0D _ _ _ 100.00
up to the corrosive environment, the brine temperature (120° to
and Communications
Wireless Instruments

Approvals FM, CSA General Purpose _ _ B _ _ 0.00


140°F), vapors, and continuous brine spray without error. (Note 3) FM Class I, II, III, Div 1, Grps A–G
• During its first six weeks in service, the Probe LR worked Intrinsically Safe (with Suitable Barrier) _ _ D _ _ 0.00
without error, even when the display window was covered with Output Hart Communications and 4-20 mA _ _ _ 10 0.00
brine crystals and discolored by the iodine brine. It even with- Accessories
stood a lightning storm, which had ruined the old gauges. It has Intrinsically Safe Handheld Programmer 7ML5830-2AH 100.00
become the plant standard for level monitoring in brine tanks. HART® Modem for PC/Simatic PDM 7MF4997-1DA 355.00
Read this and other customer success stories SIEMENS Barrier, ATEX II 1 G, EEx ia
SITRANS Probe LR Instruction Manual
7NG4122-1AA10
7ML1998-5HR01
145.00
15.00
at www.lesman.com/success/css_application.htm SITRANS Probe LR Quick-Start Manual 7ML1998-5QP81 20.00
RADAR Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
204 LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

SITRANS LR200 for Bulk Liquid Storage Levels


Dimensions
Flow Measurement
Instruments

SITRANS LR200 is ideal for chemical


storage applications. The infrared intrinsically safe hand-
held programmer lets you program See the LR300
the SITRANS LR200 in hazardous for details
areas, without opening the cover. on horn and
antenna
Features configuration
Solids Flow and Motion

• 2-wire loop-powered radar offers low-cost installation.


• Low frequency of 6.3 GHz offers high immunity against con-
densation or deposits.
• Patented infrared intrinsically safe handheld programmer.
You don’t have to open the cover — exposing the terminals
to the elements and corrosion — to plug in any program-
ming modules.
• Standard built-in display has a primary reading, an auxiliary
reading and a level bargraph.
• The rotating head swivels to line up with conduit or wiring Visit www.lesman.com
for complete specifications
Rotary and Electric

connections. After installation, just rotate the head to the


Actuator Motors

desired position for easy display viewing. This feature will as- on all the LR200 models.
sist to reduce false echoes in the vessel. After orientation, the
head can be locked into place for permanent use. Uni-construction, polypropylene rod offers superior
chemical resistance with only one material to consider for
• Very high signal-to-noise ratio for reliable performance to chemical compatability.
ranges of 66 ft. (20m). Ample excess signal to tolerate issues
siest
like condensation, turbulence, or low dielectrics. LR200 is the ea
The SITRANSkind to install. Setup can
• “Uni-construction” polypropylene rod antenna option. The
instrument of itits meters,
threads and the rod antenna are made of the same material et ed w h as few as two para ’s a cost-
be compl fo r an echo profile. It accurate
and hermetically sealed to prevent chemical ingress. The in-
with no ne ed bl e,
providing relia titive price.
ternal shield ensures that no nozzle noise will be introduced
effective choice a very compe
Combustion Safety

by the installation. A 100mm (4”) shield length is standard; a measurement at


and Efficiency

250mm (10”) version is also available.


• Flange adapter version offers modular fit with other process
connections and antenna options. LR200

• Built in HART® communications.


• Easy-to-program and diagnose with Programming Options
SIMATIC® PDM configuration software. L: Siemens’ intrinsically-safe handheld programmer; R: Siemens’ RS-232 to
• Advanced Sonic Intelligence signal-processing software HART® modem for SIMATIC PDM. See page147 for Simatic PDM software.
including Auto False-Echo Suppression, featuring automatic
and Communications
Wireless Instruments

detection and suppression of echoes from tank obstructions.


• Rugged, encapsulated enclosure is submersible and corro-
sion resistant. The potted design provides an extremely high
level of shock and vibration resistance.

Condensed specifications on page 202. Visit our


website for full details.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan RADAR

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
LEVEL 205

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Ordering Instructions
Find the table for the model you need. Then, make one selection from Please submit orders to: Siemens, c/o Lesman Instrument Company
each table section. Completed catalog numbers will look like these:
7ML5422-_ _ _ _0 7ML5423-__ _ _ _ - 0 _ _ _
7ML5424-_ _ _ _ _- 0 _ _ _ 7ML5425- _ _ _ _ _ - 0 _ _ _ Model Selection Guide — Sanitary Model
Catalog
Description Number Price
Model Selection Guide — UniConstruction Rod Antenna Sitrans LR200 Sanitary Version 6ML5424- $1210.00
Catalog Rod One Piece, PTFE Teflon 0 _ _ _ _- 780.00

Flow Measurement
Description Number Price Antenna One Piece, UHMW-PE 1 _ _ _ _- 0.00
Sitrans LR200 Uni-Construction PP Rod Antenna Model 7ML5422- $1155.00

Instruments
Process 2” Tri-Clamp, Rod Antenna Only _ AA0 _- 919.00
Antenna Polypropylene, Integral 100mm Shield, Connection 3” Tri-Clamp, Rod Antenna Only _ AB0 _- 1043.00
Type 1.5” NPT 0A _ _ _ 0.00 4” Tri-Clamp, Rod Antenna Only _ AC0 _- 1346.00
Polypropylene, Integral 250mm Shield, Process No Gasket _ _ _ _ 0- 0.00
1.5” NPT 0D _ _ _ 100.00 Seal/Gasket Mounting Clamp with Gasket (Note 4) _ _ _ _ 1 65.00
Approvals FM General Purpose _ _ B _ _ 0.00 Output Hart Communications and 4-20 mA 0A _ _ 0.00
(Note 3) FM Class I, II, Div 1, Grp A–G, Intrinsically Safe _ _ D _ _ 0.00 Profibus PA 0B _ _ 150.00
FM Class I, Div 2, Grp A–D _ _ F _ _ 0.00 Approvals FM General Purpose _ _ B _ 0.00
FM Class I, II, III, Div 1, Grp A–G _ _ J _ _ 0.00 (Note 3) FM/IS: Class I, II, Div 1, Grp A–G _ _ D _ 0.00
Output Hart Communications and 4-20 mA _ _ _ 10 0.00 FM Class I, Div 2, Grp A–D _ _ F _ 0.00

Solids Flow and Motion


Profibus PA _ _ _ 20 150.00 FM Class I, II, III, Div 1, Grp A–G _ _ J _ 0.00
Pressure Per Pressure/Temp Curves in Manual _ _ _ 0 50.00
Model Selection Guide — Rod Antenna, Flange Conn. Rating 0.5 bar (7.5 PSI) Maximum _ _ _ 1 0.00
Options Certified to DIN 50 049 Sect. 3.1/ EN 10204 -Z-C12 44.00
Catalog
Description Number Price
Sitrans LR200 Flange Adapter, PTFE Teflon Rod Antenna 7ML5423- $1210.00
Model Selection Guide — Horn Antenna, Flange Conn.
Process 2” ANSI 150 Lb, FF Flange 1FB _ _- 427.00
Connection 3” ANSI 150 Lb, FF Flange 1GB _ _- 591.00 Catalog
(316 SS) 4” ANSI 150 Lb, FF Flange 1HB _ _- 779.00 Description Number Price
6” ANSI 150 Lb, FF Flange 1JB _ _- 989.00 Sitrans LR200 Flange Adapter Horn Antenna Version 7ML5425- $1210.00
1.5” NPT Threaded 1LA _ _- 414.00 Antenna 316L Stainless Steel with PTFE Cone Emitter 0 _ _ _ _- 0.00
2” Threaded 1MA _ _- 438.00 316L SS, PTFE Cone Emitter, Purging (Note 4) 1 _ _ _ _- 515.00
Antenna None _ _ _ 0 _- 0.00 1000 mm Sliding Waveguide, (Note 5) 2 _ _ _ _- 490.00

Rotary and Electric


Extension 50mm PTFE Extension _ _ _ 1 _- 45.00

Actuator Motors
Process 2” ANSI 150 Lb, FF Flange (Note 4) _ FB _ _- 90.00
100mm PTFE Extension _ _ _ 2 _- 55.00
Connect. 3” ANSI 150 Lb, FF Flange _ GB _ _- 120.00
100mm 316 SS Shield (Note 1) _ _ _ 3 _- 0.00
(316 SS) 4” ANSI 150 Lb, FF Flange _ HB _ _- 180.00
150mm 316 SS Shield (Note 1) _ _ _ 4 _- 120.00
6” ANSI 150 Lb, FF Flange _ JB _ _- 350.00
200mm 316 SS Shield (Note 1) _ _ _ 5 _- 150.00
8” ANSI 150 Lb, FF Flange _ KB _ _- 625.00
250mm 316 SS Shield (Note 1) _ _ _ 6 _- 180.00
Process Integral Gasket (Note 2) _ _ _ _ 0- 100.00 Output Hart Communications and 4-20 mA _ _ _0 _- 0.00
Seal/Gasket FKM O-Ring (Note 2) _ _ _ _ 1- 0.00 Profibus PA _ _ _1 _- 150.00
Output Hart Communications and 4-20 mA 0A _ _ 0.00 Process FKM _ _ _ _ 0- 0.00
Profibus PA 0B _ _ 150.00 Seal/ Nitrile (Sliding Waveguide Systems Only) _ _ _ _ 1- 0.00
Gasket FFKM (-35° to 200°C) _ _ _ _ 2- 270.00
Approvals FM General Purpose _ _ B _ 0.00
(Note 3) FM/IS: Class I, II, Div 1, Grp A–G _ _ D _ 0.00 Horn Waveguide Only 0A _ _ 140.00
FM Class I, Div 2, Grp A–D _ _ F _ 0.00 Size 80mm Horn for Stillpipe Applications 0B _ _ 340.00

Combustion Safety
FM Class I, II, III, Div 1, Grp A–G _ _ J _ 0.00 100mm Horn for Stillpipe Applications 0C _ _ 340.00

and Efficiency
150mm Horn 0D _ _ 340.00
Pressure Per Pressure/Temp Curves in Manual _ _ _ 0 50.00
200mm Horn 0E _ _ 340.00
Rating 0.5 bar (7.5 PSI) Maximum _ _ _ 1 0.00
Approval FM General Purpose _ _ B _ 0.00
Options Certified to DIN 50 049 Sect. 3.1/ EN 10204 Z-C12 44.00 (Note 3) FM/IS: Class I, II, Div 1, Grp A–G _ _ D _ 0.00
Also available with 300# flanges. Call for details. FM Class I, Div 2, Grp A–D _ _ F _ 0.00
FM Class I, II, III, Div 1, Grp A–G _ _ J _ 0.00
Pressure Per Pressure/Temp Curves in Manual _ _ _ 0 50.00
LR200 Accessories — All Models Rating 0.5 bar (7.5 PSI) Maximum _ _ _ 1 0.00
Catalog
Options Certified to DIN 50 049 Sect. 3.1/ EN 10204 Z-C12 44.00
Description Number Price
IS/Infrared HART® Handheld Programmer 7ML5830-2AH $100.00 Also available with 300# flange process connections and
and Communications
Wireless Instruments

Instruction Manual for HART® Models 7ML1998-5FN02 15.00 waveguide extensions. Call for price and availability.
Quick-Start Guide for HART® Models 7ML1998-5QL82 20.00
IS/Infrared Profibus Handheld Programmer 7ML5830-2AJ 100.00 Notes and Restrictions — All Models
Instruction Manual for Profibus Models 7ML1998-5HP01 15.00
1 Requires flange connection larger than 2”, threaded connection larger than 1.5”
Quick-Start Guide for Profibus Models 7ML1998-5QG81 20.00
2 For flanged connections only. FKM O-ring for threaded connections or shielded
SIMATIC PDM v6.0 Sftware Utility for Configuring, 6ES7658-3AX06- antenna extension models.
Commissioning, and Diagnostics; (Profibus, 0YA5-PI 560.00 3 All approvals include radio FCC 6.3 GHz; Unit only rated FM intrinsically safe
HART® and 4 Tags) when used with a suitable barrier. Approval J not valid with Profibus PA output.
HART® Modem for use with Simatic PDM/PC 7MF4997-1DA 355.00 4 Available only with Pressure Rating Option 1 (0.5 bar Max.)
Siemens Barrier, ATEX II 1 G, EEx ia 7NG4122-1AA10 145.00 6 Available only with Horn Size Options C, D, or E
RADAR Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
206 TANK LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

SITRANS LR300 Microwave Pulse Continuous Level Measurement


• Liquid measurement range to 65.6 feet. • Echos from tank baffles and heating coils
are easily suppressed with self-learning
• Accuracy ±0.5” from 1.3 feet to 32.8 feet,
false-echo suppression technology!
0.25% from 32.8 feet to 65.6 feet. Can be
increased with a stillpipe or waveguide. • Internal temperature sensor (177°F limit)
helps determine failures. Ideal for cooling
• Repeatability ranges from 0.07” to 0.39”.
systems, heat shielding issues.
• New enclosure reduces costs and controls
Flow Measurement

• Modbus and HART®/mA communications


approval issues. Rugged design in Epoxy-
standard. Profibus-PA optional.
Instruments

painted aluminum or stainless steel.


• Works with Dolphin Plus software for
• New universal power supply simplifies
quick and easy configuration.
power requirements and is immune to
spikes, surges, and brownouts. • Intrinsically safe handheld programmer
approved for hazardous areas
• Improved signal-to-noise ratio for harsh
conditions such as foaming, encrustation, • Process connections, horns, and wave-
lass I,
With C . 1
condensation, and more. guide antenna options to suit any tank or
application.
• 2” threaded rod antenna and stainless steel Div l!
Solids Flow and Motion

a
shield eliminates standpipe interference!
LR300 Approv
Reliable Measurement in Extreme Conditions
The SITRANS LR300 delivers high performance level measurement at Bitumen or Hot Mix Asphalt Tanks: The
an affordable price for the chemical, petrochemical, and pharmaceutical LR300 system is proven tough, even in the
processing industries. harsh environment of a bitumen or hot
With its low frequency and high signal transmission speed, the LR300 mix asphalt tank.The rugged construction
is virtually unaffected by temperature or pressure extremes, steam, dense and chemical-resistant PTFE rod antenna
foam, vapors, condensation, dust, aggressive chemicals, encrustation, withstand harsh conditions. It’s low maintenance, without the nuisance
turbulence, and agitation. of broken floats or stuck cables typical of mechanical systems.
It uses non-contacting technology, with a high-resistance PTFE (Tef- Anaerobic Digester Tanks: The level in a digester is a critical measure­
Rotary and Electric

ment. If the top foam level gets too high, it can enter the gas collection
Actuator Motors

lon®) rod antenna that’s chemically immune and resistant to material


build-up. Sonic Intelligence signal-processing technology for superior pipeline and lead to costly maintenance. With its unique sliding wave­
reliability makes it low maintenance. guide, LR300 lets you raise the device for installation or inspection
without releasing harmful gas. The waveguide carries the radar signal
The instrument is compact, rugged, and easy to install — you just bolt from the instrument to the horn antenna, bypassing the spool and valve
the unit on a standpipe and connect it to a power supply. It can be fully components.The pipe has a clamping seal on top of the mounting flange
operational by entering as few as three parameters. There’s no need to to seal the low pressure digester gases after installation.
fill or empty the vessel for calibration or commissioning.
The SITRANS LR300 is the right choice for sophisticated monitoring
applications with communications requirements, or for tanks containing
baffles, heating coils, or other obstructions. Dimensions
Chemical Process or Reactor Tanks: The SITRANS LR300 effectively
Combustion Safety

monitors chemicals in simple storage containers or in reactor vessels


and Efficiency

where the environment and material change rapidly from one extreme
to another.The high signal‑to‑noise ratio delivers reliable performance in
these dynamic conditions.The four-wire SITRANS LR300 offers enhanced
reliability over two‑wire systems that often lack the power to process
and respond quickly, especially on low dielectric materials.
Sonic Intelligence advanced echo processing and auto false‑echo
suppression produce reliable readings even in tanks with agitators and
heating coils. The PTFE rod antenna can withstand high temperatures,
and resists chemical attack and build‑up. A self-cleaning option is avail-
able for slurries where severe buildup is expected.
and Communications
Wireless Instruments

Feature SITRANS LR300 (4 Wire)


Process tanks and reactors
Applications with baffles, heating coils, and other obstructions
Power Supply Universal AC/DC: 24V to 230V, ±15%
* Flange thickness 1”
Measurement 65 feet range
nominal.
Output 4 to 20 mA (HART model) ** Standard length.
Communications Modbus (programming) HART or Profibus-PA 2” and 4” antenna
Enclosures Aluminum housing or stainless steel extensions available.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan RADAR

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TANK LEVEL 207

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Antenna Configurations (L to R)
• Rod antenna, flat-faced flange connection.
• PTFE rod antenna with a stainless steel shield eliminates standpipe
interference. Many lengths available.
• Sanitary rod con­nection for food applications. 2”, 3”, 4” sizes available.
• 4” sanitary horn for food applications.

Flow Measurement
• Waveguide antenna for low dielectric products.

Instruments
• Sliding waveguide antenna typically for digester use with an isolation
valve between the instrument and the vessel.

Find full specs and manuals for the


LR300 at www.lesman.com Infrared IS Programmer
SITRANS LR300
Need help finding the right model? is available with

Solids Flow and Motion


Use the radar level application a patented
datasheet on page 440. Fax it to infrared handheld
Lesman for an engineering review. programmer certified
as intrinsically safe for
Not sure radar is right use in hazardous areas.
for you? Turn to page
183 and check out
our level technology
selector.

Rod Threaded Rod Sanitary Rod Sanitary Horn Horn Waveguide

Rotary and Electric


Actuator Motors
Connection Flat-face flange 1-1/2” and 2” sizes, Sanitary Tri-Clamp, Sanitary Tri-Clamp, Flat-face flange Flat-face flange
Type nominal pipe sizes NPT, BSP, G 2”, 3”, and 4” sizes 4” size only nominal pipe sizes nominal pipe sizes
(2”, 3”, 4”, and 6”) (2”, 3”, 4”, and 6”) (2”, 3”, 4”, and 6”)
Wetted Parts PTFE PTFE and 316SS UHME-PE and PTFE 304SS, PTFE 316SS, PTFE 316SS, PTFE
Extensions 2” or 4”, 2” or 4”, N/A N/A Use waveguide for Two sections (max)
PTFE or UHMW-PE PTFE or UHMW-PE extensions to 20’ long can be connected
Dielectric >3 >3 >3 >3 >3 >1.8
Constant
Insertion 16.3” 16.3” 16.3” N/A 21’ with max wave- 33’ max length
Length (Max) guide extension length (2 pieces)
Purging Option No No No No Yes Yes

Combustion Safety
(Liquid or Gas)

and Efficiency
Sliding Wave-
Guide Option Yes No No No Yes
for Digesters
Approvals Call for list Call for list 3A 3A Call for list Call for list

Condensed Specifications
Operations: Detection range: 66 feet max, liquids and slurries; Accuracy: Housing: Enclosure: Aluminum,Epoxy coated,optional stainless steel; Conduit:
±0.15%; Repeatability: 0.07” to 0.39”; Frequency: 6.3 GHz 2” x 2-1/2” NPT or M20 x 1.5 entry; Ingress protection: Type 4X/NEMA 4X,
Power: Universal AC/DC power supply: 24 to 230 VAC, ±15%, 40 to 70 Hz, Type 6/NEMA 6, IP67
28 VA (11W) or 24 to 230 VAC, ±15% (9W) Antennas: PTFE rod/stainless steel horn antenna and waveguides
and Communications
Wireless Instruments

Environmental: Location: Indoor/outdoor; Altitude: 6,561 feet; Ambient Process Connections: Flat-faced flanges, threaded and sanitary connections,
temperature: -40° to 140°F; Relative humidity: Suitable for outdoor (Type 6, 316 stainless steel, 2”, 3”, and 4” (bolt hole pattern to ANSI, DIN, and JIS sizes),
NEMA 6, IP67 enclosure); Installation category: II; Pollution degree: 4 other connections available
Interface: Analog output: Optically isolated 4-20 mA into 450Ω max, 0.02 mA Auto False-Echo Suppression: Adjustable to 65.6 feet
resolution; Dolphin/RS485 link; Programmer link: Infrared receiver; Program- Process: Material dielectric: Er>3 (for Er<3, call); Pressure (vessel): -100 kPa to
mer (remote keypad): Intrinsically safe model with EEx ia IIC T4; Display (lo- 1000 kPa; Temperature: Process: ‑40° to 392°F; Ambient: ‑40° to 140°F
cal): Alphanumeric and multi-graphic liquid crystal for readout and entry;
Modbus, HART, and Profibus-PA; Upgradable Flash via RS485 Approvals: CE, 3A, FM/CSA General Pur-
pose for Class I, Div. 1, Groups A-G
RADAR Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
208 TANK LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

SITRANS LR300 Microwave Pulse Continuous Level Measurement


Rod Antenna — Ordering Instructions Waveguide (Horn Antenna) — Ordering Instructions
Make one selection from each table below. A complete catalog number Make one selection from each table below. A complete catalog number
looks like this: 7ML5413 - _ _ _ _ _ - _ _ _ _ looks like this: 7ML5411 - _ _ _ _ _ - _ _ _ _

Please submit orders to: Siemens, Please submit orders to: Siemens,
Model Selection Guide c/o Lesman Instrument Company Model Selection Guide c/o Lesman Instrument Company
Catalog Catalog
Description Number Price Description Number Price
Flow Measurement

SITRANS LR300 Rod Antenna Model, PTFE Teflon 7ML5413- $1595.00 SITRANS LR300 Horn Antenna Model 7ML5411 - $1595.00
Instruments

2” ANSI 150 Lb., FF Flange 0FB _ _ - 368.00 Antenna 316LSS, PTFE Cone Emitter 0 _ _ _ _ - 0.00
3” ANSI 150 Lb., FF Flange 0GB _ _ - 585.00 Material 316LSS, PTFE Cone Emitter, Purging 1 _ _ _ _ - 445.00
4” ANSI 150 Lb., FF Flange 0HB _ _ - 770.00 (Note 1) Sliding 39.37” Waveguide System (Note 2) 2 _ _ _ _ - 425.00
316SS 6” ANSI 150 Lb., FF Flange 0JB _ _ - 770.00 2” ANSI 150 Lb., FF Flange _ FB _ _ - 75.00
Process 2” ANSI 300 Lb., FF Flange 0FD _ _ - 368.00 3” ANSI 150 Lb., FF Flange _ GB _ _ - 105.00
Connection 3” ANSI 300 Lb., FF Flange 0GD _ _ - 585.00 4” ANSI 150 Lb., FF Flange _ HB _ _ - 155.00
4” ANSI 300 Lb., FF Flange 0HD _ _ - 770.00 316SS 6” ANSI 150 Lb., FF Flange _ JB _ _ - 300.00
6” ANSI 300 Lb., FF Flange 0JD _ _ - 1055.00 Process 8” ANSI 150 Lb., FF Flange _ KB _ _ - 540.00
1-1/2” NPT Threaded Connection 0LA _ _ - 355.00 Connection 2” ANSI 300 Lb., FF Flange _ FD _ _ - 185.00
2” NPT Threaded Connection 0MA _ _ - 380.00 3” ANSI 300 Lb., FF Flange _ GD _ _ - 235.00
Solids Flow and Motion

None _ _ _ 0 _ - 0.00 4” ANSI 300 Lb., FF Flange _ HD _ _ - 290.00


Antenna 1.96” Extension, PTFE _ _ _ 1 _ - 85.00 6” ANSI 300 Lb., FF Flange _ JD _ _ - 485.00
Extensions/ 3.93” Extension, PTFE _ _ _ 2 _ - 110.00 6” ANSI 300 Lb., FF Flange _ KD _ _ - 865.00
Inactive 3.93” Extension, 316SS Shield (See Note) _ _ _ 3 _ - 0.00 Communi- 4-20 mA, HART, Modbus _ _ _ 0 _ - 0.00
Shield 5.90” Extension, 316SS Shield (See Note) _ _ _ 4 _ - 105.00 cations Profibus-PA, Modbus _ _ _ 1 _ - 220.00
Length 7.87” Extension, 316SS Shield (See Note) _ _ _ 5 _ - 130.00 Process FKM _ _ _ _ 0 - 0.00
9.84” Extension, 316SS Shield (See Note) _ _ _ 6 _ - 155.00 Seal Nitrile (Sliding Waveguide Systems Only) _ _ _ _ 1 - 0.00
Process Integral Gasket (FF Flange Conn. Only) _ _ _ _ 0 - 75.00 FFKM (-31° to 392°F) _ _ _ _ 2 - 230.00
Seal Viton O-Ring (Threaded Conn. Only) _ _ _ _ 1 - 0.00 Enclosure Aluminum, Epoxy Paint. 2” x 1/2” NPT 0 _ _ _ - 0.00
Enclosure Aluminum, Epoxy Paint. 2” x 1/2” NPT 0 _ _ _ - 0.00 316 Stainless Steel. 2” x 1/2” NPT 2 _ _ _ - 475.00
316 Stainless Steel. 2” x 1/2” NPT 2 _ _ _ - 413.00 Waveguide (Note 3) _ A _ _ - 120.00
Communi- 4-20 mA, HART, Modbus _ A _ _ - 0.00 3.14” Horn (Stillpipe Applications Only) _ B _ _ - 295.00
cations Profibus-PA, Modbus _ B _ _ - 192.00 5.90” Horn _ D _ _ - 290.00
Rotary and Electric

7.87” Horn _ E _ _ - 290.00


Actuator Motors

Approvals FM Class I, Div 1, Groups A-G _ _ F0 180.00


FM General Purpose _ _ G0 50.00 3.93” Horn, 5.90” Waveguide Extension _ G _ _ - 720.00
Horn Size/ 3.93” Horn, 7.87” Waveguide Extension _ H _ _ - 720.00
Note: Not available on 2” ANSI Flange or 1.5” threaded process connections. Waveguide 3.93” Horn, 9.84” Waveguide Extension _ J _ _ - 720.00
Options 5.90” Horn, 5.90” Waveguide Extension _ L _ _ - 540.00
5.90” Horn, 7.87” Waveguide Extension _ M _ _ - 540.00
Sanitary Tri-Clamp — Ordering Instructions 5.90” Horn, 9.84” Waveguide Extension _ N _ _ - 540.00
Make one selection from each table below. A complete catalog number 7.87” Horn, 5.90” Waveguide Extension _ Q _ _ - 540.00
looks like this: 7ML5412 - _ _ _ _ _ - _ _ _ _ 7.87” Horn, 7.87” Waveguide Extension _ R _ _ - 540.00
7.87” Horn, 9.84” Waveguide Extension _ S _ _ - 540.00
Please submit orders to: Siemens,
Approvals FM Class I, Div 1, Groups A-G, FCC 6.3 GHz _ _ F0 190.00
Model Selection Guide c/o Lesman Instrument Company
FM General Purpose _ _ G0 60.00
Catalog
Note 1: Not available on 2” ANSI Flange or 1.5” threaded process connections.
Combustion Safety

Description Number Price


Note 2: Available with horn size options C, D, or E only.
and Efficiency

SITRANS LR300 Sanitary Model, Tri-Clamp Connection 7ML5412 - $1595.00


Note 3: Custom length between 100 and 3000mm.
Antenna PTFE - Teflon, One Piece Rod Antenna 0A _ _ _ - 675.00
Add line item “7ML-1410-0AA00-Z-Y01. Total Insertion Length ____ mm.”
(See Note) UHMW-PE, One Piece Rod Antenna 1A _ _ _ - 0.00
2” Connection (Rod Antenna Only) _ _ A _ _ - 795.00
Configur- 3” Connection (Rod Antenna Only) _ _ B _ _ - 900.00 Please submit orders to: Siemens,
ation 4” Connection (Rod Antenna Only) _ _ C _ _ - 1160.00 Accessories Model Selection Guide c/o Lesman Instrument Company
Process None _ _ _ 00 - 0.00 Catalog
Seal Mounting Clamp with Gasket _ _ _ 01 - 55.00 Accessories for All Models Number Price
Enclosure Aluminum, Epoxy Paint. 2” x 1/2” NPT 0 _ _ _ - 0.00 English Instruction Manual 7ML1998-5CL04 $25.00
316 Stainless Steel. 2” x 1/2” NPT 2 _ _ _ - 475.00 Quick-Start Guide 7ML1998-5QA84 15.00
and Communications

Enclosure Wrench 7ML5830-1HB 5.00


Wireless Instruments

Communi- 4-20 mA, HART, Modbus _ A _ _ - 0.00


cations Profibus-PA, Modbus _ B _ _ - 220.00 Hand Programmer, Intrinsically Safe 7ML5830-2AH 100.00
RS485-RS232 Converter, Non-Isolated, Port Power 7ML1830-1HA 100.00
Approvals FM Class I, Div 1, Groups A-G _ _ F0 280.00 Hart Modem for Use with PC/Simatic PDM 7MF4997-1DA 355.00
FM General Purpose _ _ G0 60.00
For Rod Antenna, Rod, PTFE PBD-25508-A 185.00
Note: Not available on 2” ANSI Flange or 1.5” threaded process connections. Antenna 2” Antenna Extension, PTFE PBD-25509-A 45.00
Models 4” Antenna Extension, PTFE PBD-25510-A 55.00
Call for pricing on optional sanitary configurations. See page 187 for Dolphin Plus.
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan RADAR

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TANK LEVEL 209

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
SITRANS LR400 Radar for Level Measurement
Features
The ideal instrirument
ng • Four-wire frequency modulated, continuous wave radar for
for m ea su
level in dusty d
high power and ranges up to 147 feet
environments an res!
• High frequency (24 GHz) offers strong signals in dusty solids
high temperatu and liquids with dielectrics as low as 1.6
• Advanced echo processing includes false-echo suppression

Flow Measurement
amd dynamic threshold

Instruments
• Narrow beam angle allows for mounting flexibility
• Self-calibration with internal reference provides long-term
stability and repeatability
• Self-diagnostics for sensor and electronics ensure reliability
• Non-contacting technology for maintenance-free operation
• Local or remote programming with SIMATIC PDM or HART®
handheld devices

Solids Flow and Motion


• 4-20 mA HART communications protocol standard, Profibus
PA optional
• Compact design with robust housing, flange and horn com-
ponents
• Standard and explosion-proof models available
• Optional stainless steel Easy Aimer for highly sloped surfaces
and purging systems for sticky solids
LR400 Visit lesman.com for radar level
application datasheets. • Optional PTFE dust cover

Featuring four-wire power and a frequency of 24 GHz, SITRANS LR400 is dust. It penetrates even severe dust to provide reliable readings that

Rotary and Electric


the superior radar solution for level measurement of solids and liquids in help improve plant efficiency and reduce operating costs.

Actuator Motors
applications up to 147 feet.This high-power,high-frequency instrument is The LR400 for solids features an enhanced antenna design, for im-
ideal for level measurement on storage vessels used in the cement,power, proved performance and better high frequency (HF) transitions in solids
chemical, and petrochemical industries. It uses frequency-modulated applications. A larger diameter antenna base improves the gain of the
continuous wave (FMCW) radar technology combined with advanced design. And, a new lower-cost antenna design eliminates unnecessary
signal processing for accurate, reliable performance. ANSI flanges and FM/XP ratings. The LR400 is the perfect solution for use
Auto-setup makes startup easy with its eight menu-driven steps. Se- with plastic pellets, powders, lime, and more.
lect indi­vidual parameters from the menu using the infrared hand-held
programmer. You can also use a PC and Simatic PDM software for easy Precise Liquid Level Measurement
remote programming. Installation is simple and usually without inter- A high signal-to-noise ratio combined with the high frequency
ruption to your process. providees superior results in level measurement on liquids.LR400 is espe-
cially effective on low dielectric liquids, such as solvents, petrochemicals,

Combustion Safety
The new infrared hand-held programmer lets you program the LR400
wirelessly from up to two meters away. oils or liquefied petroleum gas (LPG) — even without a stillpipe.

and Efficiency
Simatic PDM (Process Device Manager) is the ideal software tool for SITRANS LR400 is virtually unaffected by vapors, high pressure, or ex-
configuration, parameter settings, record-keeping and diagnostics, in- treme temperatures often found in chemical and petrochemical industries.
cluding trend and echo profiles. PDM offers communication by HART®, Its self-calibration reference system ensures repeatability. The narrow
Profibus PA, and other protocols. See page 137 for more details. beam angle allows for greater flexibility in mounting locations.

A Solid Solution to Dust FMCW and Superior Echo Processing


The ability to penetrate dust makes SITRANS LR400 ideal for applica­ The radar instrument transmits a linear, fre-
tions on flour, fly-ash, carbon black, powders, and other dusty materials. quency modulated, continuous wave. It compares
High power, high frequency, and a narrow beam angle combine to the return signal to the transmitted signal, where
produce excellent reflection characteristics and exceptional measure­ the difference in frequency is directly related to the
and Communications
Wireless Instruments

ment performance on virtually any solids medium, regardless of particle measured distance. A fast fourier transformation
size. The strong signal-to-noise ratio and echo-processing technology (FFT) process converts the frequency spectrum of
produce reliable readings, improving plant efficiency and reducing the signal into an echo profile. Siemens Milltronics
operating costs. applies special advanced algorithms — including
automatic false-echo suppression — to the profile
In the cement industry, for example, dust has traditionally challenged to establish the correct level readings.
other level measurement instruments. Homogenizing silos produce
extreme dust conditions as material is continuously fed and aerated for You can learn more about Siemens’ patented
proper mixing. Whether it’s the homogenizing silos or vessels storing automatic false-echo suppression algorithms and
clinker, kiln dust, and finished cement, the LR400 offers a solution to self-learning features on page 188.
RADAR Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
210 TANK LEVEL Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

SITRANS LR400 Radar for Level Measurement


Specifications
Measuring Principle: 24 GHz frequency modulated continuous wave Rated Operating Conditions
Signal Processing: Digital echo processing; Self-calibration through internal Ambient Temperature: -40 to 149 °F (-40 to 65 °C)
reference Location: Indoor/outdoor
Measuring Range: 0.35 to 50 m (1.15 to 164 ft) Installation Category: II
Deadband: 0 to 350 mm from bottom edge of flange Pollution Degree: 4
Measurement Error at 25°C: ≤5mm from 2–10m, ≤15mm from 10–50 m
Flow Measurement

Design
Repeatability: ≤ 1mm
Instruments

Power Supply: 120 to 230 V AC ±15% (50/60 Hz), 6 W (12 VA) or 24 V DC


Failsafe: mA signal programmable as high, low or hold (LOE) +25/-20%, 6 W (optional)
Analog Output (HART): HART®, Optically isolated 4 to 20 mA signal Weight: Liquids: Approx. 12.2 kg (26.8 lbs) with 3” 150 PSI flange; Solids: Ap-
Load: Max. 600 Ω prox. 6.1 kg (13.4 lbs) with 3” universal flange
Communication: HART; Profibus PA (Layer 1 and 2, Class A, Profile 3.0) Enclosure: Painted diecast aluminum; IP67/Type 4X/NEMA 4X,Type 6/NEMA
optional 6; M20 x 1.5 or ½” NPT (QTY 2) cable inlets
Digital Output: Relay, normally open or closed function, max. DC 50 V, max. Antenna: Stainless steel, PTFE emitter; Short (2.9” diameter) or long horn
200 mA, rating 5 W (3.66” diameter), optional purge and PFFE lens dust cover
Dielectric Constant: >1.4 Process Connections: Liquids: 316 stainless steel flat-faced flanges, 80, 100,
Solids Flow and Motion

Process Temperature: Standard: -40 to 392 °F (-40 to 200 °C); -4 to 392 °F (-20 150 mm, bolt holes matching DIN 2527 and JIS B 2238; 316 stainless steel
to 200 °C) for SITRANS LR 400 with ATEX rating; With temperature extension raised-face flanges, 3”,4”,6”,bolt holes matching ANSI B 16.5; Solids: Universal
(Liquids only): -40 to 482 °F (-40 to 250 °C) flanges, stainless steel, flat faced, with integral Easy Aimer, 2”/50 mm, 3”/80
mm, 4”/100 mm, 6”/150 mm (mates with flange DIN 2527, ANSI B16.5, or
Vessel Pressure: Liquids: Up to 40 bar (process connection dependent); JIS B2238 bolt pattern), 0.5 bar (7.25 psi) max. pressure
Solids: 0.5 bar (7.25 psi) maximum

Level Device Shows Immediate ROI, Reduces Shutdowns


Application: Blast Furnace Iron Ore Burden Level •
Problem: A cable/weight system to measure iron ore burden level
Rotary and Electric
Actuator Motors

in the blast furnace was inconsistent, causing inefficient loads


feeding into the furnace, and leading to time-consuming and
costly furnace shutdowns.
Burden level is extremely critical in the “charging” process, not
only for proper throughput, but to maintain proper cooling and
prevent hot spots for occurring on the shell. A hot spot could
eventually cause a breakout of molten iron, causing serious
injury – sometimes even death – not to mention weeks of un-
scheduled downtime.
Current Business Result
• Broken Equipment: The existing cable and weight system was
Combustion Safety

problematic because it would hang up, and the cable would


and Efficiency

break frequently.
• High Cost of Downtime: The engineers estimate lost-ore costs
for one hour of downtime somewhere between $12,000 (small
furnace) and $20,000 (largest furnace). A typical unscheduled
shutdown for repair would last no less than two to three hours,
and would usually occur three to four times per year per furnace. Installing a non-contact radar solution to measure burden level
Since a fully integrated mill needs to make iron to produce the has increased production, reduced furnace shut-downs, and
final steel product, the costs would escalate considerably if a fur- improved product consistency. So far, LR400s have been installed
nace stayed on unscheduled shutdown long enough to interrupt in three of the four furnaces.
and Communications

steel production.
Wireless Instruments

Customer Comment
Solution Since we installed the first LR400s in summer 2003, we’ve had no
• The customer tried the Siemens LR400 non-contacting radar unscheduled shutdowns caused by burden level problems. When we
unit on one furnace and it worked well enough to implement figured out the savings, it was substantial:
this solution for all the blast furnaces in the plant. Accurate level On our small furnace, it’s between $72,000 and $144,000 per
measurement is so important that two LR400s will be used on year. On our biggest furnace, we’re saving between $120,000
each of the four furnaces for redundancy. and $240,000 per year.
Read this and other customer success stories at www.lesman.com/success/css_application.htm
Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan RADAR

V 02.2006
Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
TANK LEVEL 211

Level Measurement
Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579

Instruments
Dimensions
Certificates and Approvals (Liquids Version): Safety: CSAUS/C, CE, FM;
Radio: Europe (R&TTE, CETECOM), Industry Canada, FCC; Hazardous Areas:
ATEX II 1/2G EEx dem [ia] IIC T6; ATEX II 1/2G EEx dem IIC T6; CSA/FM Class
I, Div. 1, Groups B-D; Class II, Div. 1, Groups E-G; Class III T6; Shipping: Lloyd’s
Register of Shipping, ABS
Certificates and Approvals (Solids Version): Safety: CSAUS/C, CE, FM; Radio:

Flow Measurement
European Radio (R&TTE), Industry Canada, FCC; Hazardous Areas: FM/CSA
Class II, Div. 1, Groups E-G, Class III; ATEX II 1/2 D T6

Instruments
Programming
Ifrared: Intrinsically Safe Siemens Milltronics infrared receiver handheld
programmer; Approvals: IS model with ATEX EEx ia IIC T4; FM/CSA Class I,
Div. 1, Groups A-D T6 @ ambient temperature 40 °C (104 °F) max.
HART®: Handheld communicator
PC: Siemens Simatic PDM, Windows®-based software
Display: Local Alphanumeric LCD for readout and entry

Solids Flow and Motion


Ordering Instructions
Select one option from each table section below. A complete catalog
number looks like this: 7ML5421 - _ _ _ _ _ - _ _ _ _

Please submit orders to: Siemens, c/o Lesman Instrument Company

Model Selection Guide — LR400 for Liquids


Catalog
Description Number Price
SITRANS LR400 for Liquid Storage Vessels 7ML5421- $2790.00 Ordering Instructions

Rotary and Electric


Actuator Motors
Process ‑40° to 284°F 0 _ _ _ _ - 0.00 Select one option from each table section below. A complete catalog
Temperature ‑40° to 482°F Temperature Extension 1 _ _ _ _ - 260.00 number looks like this: 7ML5420 - _ _ _ _ _ - _ _ _ _
3” Universal Flat Face (Note 1) _ A _ _ _ - 95.00
Please submit orders to: Siemens, c/o Lesman Instrument Company
4” Universal Flat Face (Note 1) _ B _ _ _ - 140.00
6” Universal Flat Face (Note 1) _ D _ _ _ - 200.00
3”, ANSI 150 lb. Class, Raised Face _ E _ _ _ - 165.00 Model Selection Guide — LR400 for Solids
3”, ANSI 300 lb. Class, Raised Face _ F _ _ _ - 240.00 Catalog
Process 4”, ANSI 150 lb. Class, Raised Face _ J _ _ _ - 210.00 Description Number Price
Connection 4”, ANSI 300 lb. Class, Raised Face _ K _ _ _ - 300.00 SITRANS LR400 for Bulk Solids Storage Vessels 7ML5420- $2790.00
6”, ANSI 150 lb. Class, Raised Face _ N _ _ _ - 270.00
Process 4” Universal Flat Face 0C _ _ _ - 140.00
Antenna Long, 3.66” Diameter, for 4” Nozzles _ _ D _ _ - 0.00 Connection 6” Universal Flat Face 0D _ _ _ - 200.00
Horn Short, 2.9” Diameter, for 3” Nozzles _ _ K_ _ - 0.00
Antenna 4” Horn Antenna for 4” Nozzles _ _ D00 - 0.00

Combustion Safety
Purging None _ _ _ 0 _ - 0.00 Horn 4” Horn Antenna with 4” Extension _ _ J00 - 95.00

and Efficiency
Option Antenna Purging System (Note 1) _ _ _ 1 _ - 220.00 4” Horn Antenna with 8” Extension _ _ K00 - 190.00
Process PTFE for ‑40° to 482°F Flange _ _ _ _ 1 - 70.00 Output HART, 4 to 20 mA 0 _ _ _ 0.00
Seal/Gasket FKM for ‑4° to 392°F Flange (Note 2) _ _ _ _ 3 - 0.00 Profibus PA 1 _ _ _ 230.00
Output HART, 4 to 20 mA 0 _ _ _ 0.00 Power 120 to 230 VAC, 2 x 1/2” NPT _ C _ _ 0.00
Profibus PA 1 _ _ _ 230.00 Supply 24 VDC, 2 x 1/2” NPT _ F _ _ 91.00
Power 120 to 230 VAC, 2 x 1/2” NPT _ C _ _ 0.00 Approvals CSA, General Purpose _ _ B _ 0.00
Supply 24 VDC, 2 x 1/2” NPT _ F _ _ 91.00 CSA/FM, Class II Div 1, Gr E-G, Class III _ _ C _ 100.00
Approvals CSA, General Purpose _ _ B _ 0.00 Display Local Display _ _ _ 2 0.00
FM, Hazardous Locations (Note 2) _ _ T _ 150.00
CSA Hazardous Locations (Note 2) _ _ U _ 150.00 Accessories
and Communications

Intrinscally Safe Infrared Handheld Programmer 7ML5830-2AJ 100.00


Wireless Instruments

Display Local Display _ _ _ 2 0.00


PTFE Dust Cover for 4” Horn 7ML1830-1KF 100.00
Accessories HART® Modem for PC/Simatic PDM 7MF4997-1DA 355.00
Intrinscally Safe Infrared Handheld Programmer 7ML5830-2AJ 100.00 English Operation Manual 7ML1998-5HZ01 10.00
PTFE Dust Cover, Long Horn PBD-51035222 100.00 LR400 Quick-Start Manual 7ML1998-5QN83 15.00
HART® Modem for PC/Simatic PDM 7MF4997-1DA 355.00
English Operation Manual 7ML1998-5FH05 10.00
LR400 Quick-Start Manual 7ML1998-5QN83 15.00
See page 147 for details on Siemens’ Simatic PDM
software and accessories.
Note 1: Units with universal flat face flange process connections require antenna
purging system. Not sure what you need? Fill out the radar application
Note 2: Not available on temperature extension models. datasheet on page ___ and fax it back to Lesman.
SHEER Illinois, Indiana, Iowa, and SW Michigan Lesman Instrument Company Wisconsin, and Upper Peninsula Michigan

V 02.2006
212 POWER Phone: 800-953-7626 • 630-595-8400 www.lesman.com Phone: 800-837-1700 • 262-790-5578
Level Measurement

Fax: 630-595-2386 sales@lesman.com Fax: 262-790-5579


Instruments

Cross-Reference
Finding the Right Siemens
All Milltronics products now have Siemens model numbers.
Siemens See
Configuration Tool!
Your Milltronics Product Key # Page Need help finding the best configuration tools for your Siemens
CLS 100 7ML5501 164 level instrumentation? We’ve made it easy! Just find your product
CLS 200 7ML5502 166 in the chart below, and follow the row across to see what tools are
available — from local pushbuttons to Simatic PDM software, the
Flow Measurement

CLS 200 Welded Flange 7ML5504 Call


CLS 200 Welded Flange/Teflon Coated 7ML5505 Call configuration option you need is here!
Instruments

CLS 300 7ML5510 168


CLS 300 High Temp 7ML5507 Call

tto he ct
u

d
sh w rod
CLS 300High Temp/Welded Flange 7ML5508 Call

el
ns /
Capacitance Products

hi ndh
s
P

er
CLS 300 Welded Flange 7ML5506 Call

M
bu itc

et

a
nt /

PD
CLS Flanges 7ML1500 165

Ke iom

Do s H

+
te ch

Si ard
Pu ry S

n
Po wit

en

ic
LC500-D (was Mercap MCP01 D Series Flange) 7ML5520 Call

at
yb

lp
em
ta

ps

m
LC500-S (was Mercap MCP01 Flanged/Cable) 7ML5512 Call

Ro

Di

Si
LC500-S (was Mercap MCP01 Flanged/Rigid) 7ML5516 Call Siemens Capacitance Instruments
LC500-S (was Mercap MCP01 One-Piece Flange) 7ML5518 Call Pointek CLS 100 3
LC500-S (was Mercap MCP01 Threaded/Cable) 7ML5511 Call
LC500-S (was Mercap MCP01 Threaded/Rigid) 7ML5514 184 Pointek CLS 200 3
Solids Flow and Motion

LC500-S (was Mercap MCP02 Flange/16mm Rod) 7ML5527 Call Pointek CLS 300 3
LC500-S (was Mercap MCP02 Flange/24mm Rod) 7ML5528 Call Pointek CLS 500 3 3 Hart
LC500-S (was Mercap MCP02 Thread/16mm Rod) 7ML5525 Call
LC500-S (was Mercap MCP02 Thread 24mm Rod) 7ML5526 Call SITRANS LC300 3 3
LC500-S (was Mercap MCP03 Sanitary/16mm) 7ML5534 184 SITRANS LC500/Mercap 3 3 Hart
LC500-S (was Mercap MCP03 Sanitary/24mm) 7ML5535 184
AiRanger DPL Plus/SPL (now SITRANS LU01/02) 7ML5004 194
AiRanger XPL Plus (now SITRANS LU10) 7ML5007 196

tto he ct
u
Ultrasonic Products

MiniRanger Plus 7ML1016 187

d
sh w rod

el
ns / s
MultiRanger 100/200 (was MultiRanger Plus) 7ML5033 190

hi ndh
s
P

er

M
bu itc

et
The Probe 7ML1201 186

a
nt /

PD
Ke iom

Do s H

+
te ch

Si ard
Pu ry S

n
ULS 200 7ML1510 172

Po wit

en

ic
o

at
yb

lp
em
ta

ps
OCM III 7ML1002 238

m
Ro

Di

Si
EnviroRanger ERS500 7ML1001 193 Siemens Radar Instruments
Rotary and Electric
Actuator Motors

HydroRanger Plus Rack/Panel 7ML1025 Call


HydroRanger Plus Wall 7ML1028 Call SITRANS LR200 3 3 Hart,
HydroRanger 200 (was HydroRanger) 7ML5034 182 Profibus
LR300 Horn Antenna 7ML5411 206 SITRANS LR300 3 3 Hart,
Radar LR300 Rod Antenna 7ML5413 206 Profibus
Products LR300 Sanitary 7ML5412 206 SITRANS LR400 3 3 Hart,
LR400 for Liquids 7ML5421 209 Profibus
PLS 200 (Now LPS200) 7ML5710 162 SITRANS Probe LR 3 3 Hart
Paddle and PLS 200 Cable Extension 7ML5714 162
Vibration PLS 200 Extended/Rigid Extension 7ML5712 162
Products VLS 200 (Now LVS200) 7ML5720 163
t
sh wi duc

d
el
ps ons s/

hi ndh
MFA-4P 7MH7144 242
oa ters
o

tt he
Pr
Combustion Safety

M
bu tc

Motion and MFA-4P Probes 7MH7146 242


e

PD
te ch/
Ke iom

Do s H

m +
rd
and Efficiency

Pu ry S

Speed Sensors SITRANS AS100 7MH7560 240


n
en
Po wit

ic
nt

at
em
yb

lp
ta

SITRANS CU-02 7MH7562 240


Ro

Di

Si

Si

VS100 Velocity Sensor 7ML1030 Call Siemens Ultrasonic Instruments


ST-H 7ML1100 199 EnviroRanger DPS300 3 3
XCT-12 7ML1136 199
XCT-8 7ML1132 199 HydroRanger 200 3 3 3 Modbus
XLS-60 7ML1129 Call HydroRanger Plus 3 3
XLT-30 7ML1141 Call MiniRanger PLUS 3 3
Echomax XLT-60 7ML1145 Call
Ultrasonic XPS-10 7ML1115 198 MultiRanger 100/200 3 3 3 Modbus
Transducers XPS-10F 7ML1170 198 MultiRanger Plus 3
XPS-15 7ML1118 198
and Communications
Wireless Instruments

The Probe 3
XPS-15F 7ML1171 198
XPS-30 7ML1123 199 SITRANS LU01
XPS-40 7ML1127 199 (AiRanger SPL+) 3 3
XRS-5 7ML1106 199 SITRANS LU02
AO 10 (Now SITRANS LU AO) 7ML1810 196 (AiRanger DPL+) 3 3
SAM 20 (Now SITRANS LU SAM) 7ML1811 196 SITRANS LU10
Accessories TS-2 7ML1812 Call (AiRanger XPL+) 3 3
TS-3 7ML1813 Call SITRANS Probe LU 3 3 Hart
Dolphin Plus 7ML1841 187
Easy Aimers 7ML1830-1A 197 ULS 200 3

You might also like