Product Catalogue

Power cables
Linking the Future
As the worldwide leader in the cable In our energy business, we design, produce,
industry, Prysmian Group believes in the distribute and install cables and systems for
effective, efficient and sustainable supply of the transmission and distribution of power at
energy and information as a primary driver in the low, medium, high and extra-high voltage.
development of communities. In telecoms, the Group is a leading
With this in mind, we provide major global manufacturer of all types of copper and fibre
organisations in many industries with best- cables, systems and accessories - covering
inclass cable solutions, based on state-of-the-art voice, video and data transmission.
technology. Through two renowned commercial Drawing on over 130 years’ experience and
brands - Prysmian and Draka - based in almost continuously investing in R&D, we apply
50 countries, we’re constantly close to our excellence, understanding and integrity to
customers, enabling them to further develop the everything we do, meeting and exceeding the
world’s energy and telecoms infrastructures, and precise needs of our customers across all
achieve sustainable, profitable growth. continents, at the same time shaping the
evolution of our industry.

Taking care of the Baltics


Establishment of Keila’s plant dates back As the world leader in cabling, we draw on
to 1968 when Keila Kaabel manufacturing global expertise and local presence to work in
plant was established and production of close proximity with our customers, delivering
electrical cables in Keila started. In 1992, Nokia products and service platforms, built on easy
Cable acquired 58.8% shares of Keila Kaabel contact, customised solutions and
manufacturing plant. In 2003, the ownership effective supply chains, meeting their
rights were transferred to Draka Holding after specialised requirements, to help them drive
acquisition of Nokia Cable.In 2011, Prysmian the wheels of industry and achieve
and Draka merged and gave birth to the cable sustainable growth and profitability.
industry’s leader worldwide. 66 % of Draka Prysmian Group believes in the effective,
Keila Cables belonged to the Prysmian Group efficient and sustainable supply of energy and
until 2014, when Prysmian Group finalized the information as a primary driver in the
acquisition of the remaining shareholding part. development of communities.
In 2016
,Draka K
manufa eila Cables
ctured

Made in Keila. 31 15
Due to belonging to the world’s largest cable manufacturer, Prysmian Group, we have
7
kilomet
ers of q
ualit y c
17 research and development centers around the world. Here in Keila we combine the able
world-wide expertise with local knowledge. This gives us the ability to develop solutions
that not only meet required standards but also empowers us to develop tailored
solutions according to specific needs.
Afumex
– halogen free cable
Afumex is a series of halogen-free flame retardant cables that can save lives and money in case
of fire. The black toxic smoke that obstructs the evacuation is gone, just as the corrosive acid that
destroys metal and electronic devices. What remain are the flexible and user-friendly qualities,
which make these cables easy to install. It’s time to choose a new path – the safe and sound one-
Afumex.
Saves money Saves lives Better for health & environment

A fire often entails serious financial For people present at a fire site, there Various types of ftalates are added in
losses due to damage to electronics, are three crucial factors affecting their the process of PVC production. Their
equipment and buildings. A contributing ability to quickly find an exit: smoke main purpose is to make the plastic
factor to these losses is the emission of development, visibility and content of soft and mouldable. But in the recent
hydrochloric acid from traditional PVC toxic substances in the inhaled air. years, research has proved that these
cables on fire. Hydrochloric acid Halogen-free and flame-retardant substances may be hazardous to health
corrodes and destroys electronics and cables emit less and lighter smoke than and cause cancer and hormonal
causes metals to corrode quickly. At a PVC cables in case of a fire. The smoke disturbances. Burning PVC also emits
fire site with halogen-free cables also contains lower quantities of toxic dioxins which are extremely hazardous
installed, a harmless white powder substances. Consequently, people in a to the environment.
develops instead which minimizes room exposed to fire have better Above all, they are poorly degradable
damage to both buildings and visibility and more time to find exits, and remain in the fat tissue of both
equipment. The fire site is also which increases the probability of humans and animals for a long time. As
significantly easier and less expensive escape and survival. halogen-free cables neither contain
to decontaminate which in its turn ftalates nor emit dioxins when burning,
allows faster re-establishing of they are a good choice for our health
production. and environment.

Halogen-free cable Traditional cable

Low smoke emission. Intense smoke emission.

Light smoke, easy to search for escape routes. Dense smoke, hard to find escape routes.

Less toxic gases, easier evacuation. Toxic smoke, interferes with survival.

A harmless white powder is formed, Emits hydrochloric acid, destroys electronics and corrodes
electronics- and equipment-friendly. reinforcement bars.

Easier to decontaminate, shorter production stops. Complicates decontamination, longer production stops.

Better for the environment. Environmentally more hazardous, contains ftalates and dioxin.
Power cables are the backbone of energy systems. Therefore, the quality of these cables are essential in
ensuring continuous energy flow to consumers. Using cables with poor quality can significantly increase the
probability of faults in energy systems that can be very costly or even dangerous to people.
Table of contents
Our cables are tested in accordance with all applicable standards and are produced according to the needs of POWER CABLES
our customers. Continuous improvement regarding materials and technology to provide the best quality on the
market is our priority.
Bare conductors 8 Power cables 24 kV 56

Product range covers a broad spectrum of power cables based on the market needs. Cables are available from A 8 AXLJ-TTCL TSLF 12/20(24) kV 56
low-voltage bare conductors to high-voltage watertight underground cables and even submarine cables. ACSR 10 AXLJ-TTCL TSLF Triplex 12/20(24) kV 58
HK 12 AHXAMK-W 12/20 (24) kV 60
Application, compliance with standards and important parameters regarding specific cable are shown on the AXLJ-RMF 12/20(24) kV 62
product page of each cable. In addition to the products included in this catalogue, also other types of power AXQJ-RMF Pure 12/20(24) kV 64
cables are available, as agreed separately with the customer. Aerial 14
AXCLJ-TT 12/20(24) kV 66
AMKA 0,6/1(1,2) kV 14
AXQJ-TT Pure TSLI 12/20(24) kV 68
EX 0,6/1(1,2) kV 16
AXALJ-TT 12/20(24) kV 70
SAX-W® 20 kV 18
HXCMK 20 kV 72
CCST-W 20 kV 20
FXLJ-TT TSLE 12/20(24)kV 74
CCSX AL3 WK 20 kV 22
Power cables 36 kV 76
AXLJ-TT TSLE 18/30(36) kV 76
Power cables 1 kV 24 AXLJ-TTCL TSLF 18/30(36) kV 78
AXPK 1 core and AXPK-Plus 1 core 0,6/1(1,2) kV 24 AXQJ-TT Pure TSLI 18/30(36) kV 80
XPK 1 core and XPK-Plus 1 core 0,6/1(1,2) kV 26
AXPK-PLUS 0,6/1(1,2) kV 28
Power cables 42 kV 82
AXPK 0,6/1(1,2) kV 30
AXLJ-TT TSLE 20,8/36(42) kV 82
ARLC and ARLC-PLUS 0,6/1(1,2) kV 32

Power cables 52 kV 84
Power cables 12 kV 34
AXLJ-TTCL TSLF 26/45(52) kV 84
AXLJ-TTCL TSLF 6/10(12) kV 34
AXQJ-TT Pure 26/45(52)kV 86
AXQJ-TT Pure TSLI 6/10(12) kV 36
AXLJ-TTCL TSLF Triplex 6/10(12) kV 38
AXQJ-TT Pure TSLI Triplex 6/10(12) kV 40 Cable designations 89
AHXAMK-W 6/10(12) kV 42
Cable Designations used in Sweden 90
AXLJ-RMF 6/10(12) kV 44
Cable Designations used in Norway 91
AXQJ-RMF Pure 6/10(12) kV 46
Cable Designations used in Finland 92
AXCLJ-TT 6/10(12) kV 48
Technical data 94
AXALJ-TT 6/10(12) kV 50
FXLJ-TT 6/10(12) kV 52 General information 96

FXLJ-TTCL TSLF 6/10(12) kV 54 General terms and conditions of supply 96


Recommendations for cable laying 96
Sheath testing in medium voltage cables 98

Standard drums, dimensions and weights 99


Drum handling guide 100
Standard delivery length Delivery Package SAP Number
[m]
Bare conductors A 25 4000 K8 4741532250117 20074932
A 35 4000 K9 4741532250124 20074933
A A 70 2500 K11 4741532250148 20074935
A 50 3500 K11 4741532250131 20074934

Product Name Diameter over wire Weight [kg/km] Number of wires Min. tensile strength of the conductor
[mm] [kN]
A 25 2,13 24,9 68 7 4,50
A 35 2,50 34,3 94 7 5,91
A 50 3,00 49,5 135 7 8,19
A 70 3,55 69,3 189 7 11,28

Application Product Initial modulus of Final modulus of Max DC Resistance Current Max. permisible short
Bare conductor for overhead power transmission. Name elasticity of conductor elasticity of conductor expansion of messenger at +20°C [Ω/km] rating in air, circuit current for 1 sec.,
[N/mm2] [N/mm2] [N/mm2] [A] [kA]
A 25 41000 60000 23x10-6 11,498 136 2,5
A 35 41000 60000 23x10-6 0,8347 170 3,4
Approval A 50 41000 60000 23x10-6 0,5784 215 5,0
CE A 70 41000 60000 23x10-6 0,4131 265 7,0

Standard
GOST 889-80

Construction
Cable Shape Round.
Conductors Stranded aluminium conductor.
Conductor Insulation No insulation.
Marking of cores No marking.

Temperature
Maximum operating Temperature 80°C

Features
Fire Propagation Nothing material to burn.
UV resistance Good.
REACH/SVHC declaration The cable does not contain any substances on the REACH/SVHC list.
RoHS declaration All substances of the cable meet the requirements of RoHS directive.

Electrical
Max. short circuit temperature [°C] 200°C

8 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-10-13
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 9
Standard delivery length Delivery Package SAP Number
[m]
Bare conductors ACSR 34/6 SPARROW 2500 K9 4741532250254 20074938
ACSR 54/9 RAVEN 2200 K11 4741532250278 20074939
ACSR ACSR 85/14 PIGEON 2000 K12 4741532250285 20074940
ACSR 242/39 HAWK 2500 K20 4741532250322 20166519
ACSR 305/39 DUCK 2200 K26 4741532250339 20074941
ACSR 565/72 FINCH 1200 K22 4741532250353 20074942

Product Name Number of wires Conductor Cable weight Max. permisible short
(aluminium/steel) dimension [mm] [kg/km] circuit current for 1 sec. **
[kA]
ACSR 34/6 SPARROW 6/1 8,1 39,5 137 3,7
ACSR 54/9 RAVEN 6/1 10,1 62,4 216 5,8
Application ACSR 85/14 PIGEON 6/1 12,8 99,3 344 9,2
Bare conductor for overhead power transmission. ACSR 242/39 HAWK 26/7 21,8 281 976 26,1
ACSR 305/39 DUCK 54/7 24,1 344 1151 32,5
ACSR 565/72 FINCH 54/19 32,9 637 2123 60,1

Flame retardance Approval


Product Name Max DC Resistance at Min. tensile strength Initial modulus of Final modulus of Current rating
Flame retardant - Not applicable CE
+20°C [Ω/km] of the conductor [kN] elasticity of conductor elasticity of conductor expansion of in air* [A]
[N/mm2] [N/mm2] conductor [1/k]
ACSR 34/6 SPARROW 0,848 12,2 64000 78000 19,2x10-6 210
ACSR 54/9 RAVEN 0,536 17,11 64000 78000 19,2x10-6 280
Standard ACSR 85/14 PIGEON 0,337 24,13 64000 78000 19,2x10-6 360
IEC 61089 Overhead stranded conductors ACSR 242/39 HAWK 0,120 84,9 61000 75500 19,2x10-6 745
EN 50182 Conductors for overhead lines
SFS 5701 Overhead conductor wires and steel ropes. ACSR 305/39 DUCK 0,0949 96,8 50000 67000 19,3x10-6 845
ACSR 565/72 FINCH 0,0512 174 46000 63000 19,3x10-6 1250

Construction
Cable Shape Round.
Conductors Conductor consists of aluminium and galvanized steel wires.
Center conductor Steel.
Conductor Insulation No insulation.
Marking of cores No marking.

Temperature
Maximum operating Temperature 80°C

Features
Fire Propagation Nothing material to burn.
UV resistance Good
REACH/SVHC declaration The cable does not contain any substances on the REACH/SVHC list.
RoHS declaration All substances of the cable meet the requirements of RoHS directive.

Electrical
Max. short circuit temperature [°C] 200°C

10 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. Data fromin2017-10-09
product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 11
Standard delivery length Delivery Package SAP Number
[m]
Bare conductors HK 16 / 7x1,68 1000 K6 4741532250018 20162343
HK 25 / 7x2,12 500 K6 4741532250025 20162344
HK HK 35 / 7x2,50 1000 K6 4741532250032 20162345
HK 50 / 19x1,77 1000 K7 4741532250049 20162346
HK 70 / 19x2,12 1000 K8 4741532250056 20162347
HK 95 / 19x2,50 1000 K9 4741532250063 20162348
HK 150 / 37x2,23 500 K11 4741532250087 20194993
HK 120 / 37x2,01 500 K9 4741532250070 20162349

Product Name Conductor dimension Cross section [mm2] Number of wires Cable weight Max DC Max. permisible short
[mm] [kg/km] Resistance at circuit current for 1 sec.
+20°C [Ω/km] * [kA]
Application HK 16 / 7x1,68 5,1 15,5 7 140 1,15 2,3
Grounding wire for fixed installations. HK 25 / 7x2,12 6,4 24,7 7 222 0,727 3,8
HK 35 / 7x2,50 7,5 34,4 7 309 0,524 5,3
HK 50 / 19x1,77 8,9 46,8 19 422 0,387 7,2
HK 70 / 19x2,12 10,6 67,1 19 606 0,268 10,3
Flame retardance Approval HK 95 / 19x2,50 12,5 93,3 19 843 0,193 14,3
Flame retardant - Not applicable CE HK 120 / 37x2,01 14,1 117 19 1062 0,153 18
HK 150 / 37x2,23 15,6 148 37 1338 0.124 22,6
* Initial temperature of conductor before short circuit 40°C, final temperature of conductor after short circuit 200°C

Standard
IEC 60228 Conductor standard

Construction
Cable Shape Round
Conductors Concentric stranded soft copper conductor
Conductor Insulation No insulation
Marking of cores No marking

Features
Fire Propagation Nothing material to burn
UV resistance Good

Electrical
Max. short circuit temperature [°C] 200°C

12 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. Data fromin2017-10-09
product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 13
Standard delivery length Delivery Package SAP Number
[m]
Covered overhead lines AMKA 1x16+25 2000 K11 4741532100009 20074959
AMKA 3x16+25 1000 K12 4741532100023 20074961
AMKA 0,6/1(1,2) kV AMKA 3x25+35 1000 K14 4741532100047 20074963
AMKA 3x35+50 1000 K16 4741532100054 20074964
AMKA 3x50+70 1000 K18 4741532100061 20074965
AMKA 3x70+95 500 K14 4741532100078 20074966
AMKA 3x120+95 500 K18 4741532100085 20074967

Product Name Diameter over bare Diameter over Conductor weight Cable weight
conductor [mm] messenger [mm] [mm]* [kg/km] [kg/km]
AMKA 1x16+25 4,4 5,8 11 100 135
AMKA 3x16+25 4,4 5,8 20 185 270
Application AMKA 3x25+35 5,8 6,8 23 285 390
Aerial bundled power cable with aluminum conductor. AMKA 3x35+50 6,8 8 27 390 530
AMKA 3x50+70 8,0 9,6 31 540 700
AMKA 3x70+95 9,6 11,3 36 775 1000
AMKA 3x120+95 12,7 11,3 42 1185 1500
Flame retardance Approval *Circumferance divided by π (Pi).
Flame retardant - Not applicable CE

Product Name Min. permissible Min. permissible Min.tensile strength Initial modulus of Final modulus of
bending radius bending radius at of the messenger elasticity of elasticity of expansion
during laying [m] final installation [kN] messenger messenger expansion of
Standard [m] [N/mm2] [N/mm2] messenger
SFS 2200 Aerial bundled cable AMKA [N/mm2]
HD 626 S1 Overhead distribution cables
IEC 60228 Conductor standard AMKA 1x16+25 0,28 0,2 7,4 55 000 63 000 23x10-6
AMKA 3x16+25 0,42 0,3 7,4 55 000 63 000 23x10-6
AMKA 3x25+35 0,5 0,35 10,3 55 000 63 000 23x10-6
AMKA 3x35+50 0,58 0,41 14,2 55 000 63 000 23x10-6
Construction AMKA 3x50+70 0,66 0,47 20,6 55 000 63 000 23x10-6
Cable Shape Insulated conductors are laid up around the the messenger. AMKA 3x70+95 0,78 0,55 27,9 55 000 63 000 23x10-6
Conductors 16 mm2: round and solid aluminium conductor; AMKA 3x120+95 0,92 0,65 27,9 55 000 63 000 23x10-6
25-120 mm2: round, stranded and compacted aluminium conductor
Conductor Insulation Black UV and weather resistant PE compound
Marking of cores Phase conductors: 2,3 or 4 longitudinal ridges
Product Name Max DC AC resistance of Max DC Resistance Inductance Max. permisible Max. permisible short
Optional conductor: no ridges
Example of marking on sheath AMKA 3x16+35 1 kV DRAKA "Production number", "Date and time", metre marked Resistance of phase** [Ω/km] of messenger* [mH/km] short circuit current circuit current for 1 sec.,
phase* [Ω/km] [Ω/km] for 1 sec., phase messenger*** [kA]
Temperature conductor ***[kA]
Maximum operating Temperature 70°C AMKA 1x16+25 1,91 2,3 1,38 0,29 1,0 1,5
Temparatures at installation [°C] Lowest cable temperature during installation: -20 ºC , below 0 ºC special precaution is
recommended. AMKA 3x16+25 1,91 2,3 1,38 0,35 1,0 1,5
AMKA 3x25+35 1,2 1,4 0,986 0,34 1,6 2,1
Features AMKA 3x35+50 0,868 1 0,720 0,34 2,3 3,0
UV resistance Good AMKA 3x50+70 0,641 0,77 0,493 0,33 3,2 4,3
Min. Bending radius at final installation 14 x D AMKA 3x70+95 0,443 0,53 0,363 0,31 4,5 5,9
Min. Bending radius at during installation 20 x D
AMKA 3x120+95 0,253 0,3 0,363 0,3 7,8 5,9
Electrical
Max. short circuit temperature [°C] 135°C (5s) *** Initial temp. of conductor before short circuit - 70ºC, final temp. after short circuit - 135ºC.

14 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 15
Standard delivery length Delivery Package SAP Number
[m]
Covered overhead lines EX 2x25 500 K9 4741532100108 20074968
EX 3x25 500 K9 4741532100115 20074969
EX 0,6/1(1,2) kV EX 3x50 500 K11 4741532100139 20074971
EX 3x95 500 K14 4741532100177 20074974
EX 4x16 1000 K11 4741532100191 20130697

Standard delivery length Delivery Package SAP Number


[m]
EX 4x25 500 K11 4741532100122 20074970
EX 4x35 500 K11 4741532100153 20141393
EX 4x50 500 K11 4741532100146 20074972
EX 4x50, T1000 1000 K18 4741532100221 20204660
Application
EX 4x70 1000 K18 4741532100160 20074973
Aerial bundled power cable with aluminium conductor.
EX 4x95 500 K14 4741532100184 20074975
EX 4x95, T1000 1000 K20 4741532100184 20204661

Alternative Product Name Flame retardance Approval Cable Cable Min.permissible Min. permissible bending Min.strength of Max. DC Max. permisible
CENELEC N1ED4-AR Flame retardant - Not applicable CE diameter weight the conductor[kN] resistance of short circuit current
[mm] laying [m] [m] conductor
[Ω/km]
EX 2x25, 1kV 18 205 0.4 0.28 4,1 1.2 1.8
Standard EX 3x25, 1kV 20 305 0.5 0.35 4,1 1.2 1.8
HD 626-3I Overhead distribution cables EX 3x50, 1kV 25 525 0.44 0.31 7.3 0.641 3.6
IEC 60228 Conductor standard EX 3x95, 1kV 34 1000 0.64 0.45 13.7 0.320 6.8
EX 4x16, 1kV 18 265 0.36 0.25 2.6 1.91 1.1
EX 4x25, 1kV 22 405 0.68 0.48 4,1 1.2 1.8
EX 4x35, 1kV 24 520 0.35 0.25 5.6 0.868 2.5
Construction EX 4x50, 1kV 28 700 0.474 0.33 7.3 0.641 3.6
Cable Shape Round EX 4x50, 1kV T1000 28 700 0.56 0.39 7.3 0.641 3.6
Conductors Round, stranded and compacted aluminium conductor
Conductor Insulation Black UV and weather resistant PE compound EX 4x70, 1kV 32 1000 0.56 0.39 10.4 0.443 5.0
Marking of cores Marked with longitudinal ridges, 2-core: Neutral-conductor - no ridge, Phase 1 - 1 ridge, EX 4x95, 1kV 38 1350 0.76 0.53 13.7 0.320 6.8
3-core: Phase 1 – 1 ridge, Phase 2 – 2 ridges, Phase 3 – 3 ridges,
4-core: Neutral-conductor - no ridge, Phase 1 - 1 ridge, Phase 2 - 2 ridges, Phase 3 - 3 ridges EX 4x95, 1kV T1000 38 1350 0.76 0.53 13.7 0.320 6.8
Example of marking on sheath EX 4x50 1 kV DRAKA "Production number", "Date and time", metre marked *Conductor temperature 20ºC
** Initial temperature of conductor before short circuit 70ºC, final temperature of conductor after short circuit 135ºC
Temperature
Maximum operating Temperature 70°C

Features
UV resistance Yes
Min. Bending radius at final installation 14 x D
Min. Bending radius at during installation 20 x D
REACH/SVHC declaration Fulfills the REACH requirements
RoHS declaration Fulfills the RoHS requirements

Electrical
Max. short circuit temperature [°C] 135°C (5s)

16 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 17
Standard delivery length Delivery Package SAP Number
[m]
Covered overhead lines SAX-W 35 2000 K11 4741532130709 20074926
SAX-W 50 2000 K11 4741532130716 20074927
SAX-W® 20 kV SAX-W 70 2000 K12 4741532130723 20074928
SAX-W 95 2000 K14 4741532130730 20074929
SAX-W 120 2000 K16 4741532130747 20074930
SAX-W 150 2000 K18 4741532130754 20074931

Product Name Diameter over Diameter over Cable weight Min. permissible Min.permissible Min. tensile strength
conductor [mm] covered conductor [kg/km] bending radius bending radius at final of the conductor[kN]
[mm] during laying [m] installation [m]
SAX-W 35 6,9 11,5 160 0,16 0,11 11,2
SAX-W 50 8,0 12,7 200 0,18 0,13 15,5
Application SAX-W 70 9,7 14,3 270 0,2 0,14 22,5
Aerial power cable with stranded and compacted aluminium conductor. SAX-W 95 11,3 16,1 350 0,22 0,16 30,4
SAX-W 120 12,8 17,6 425 0,25 0,18 38
SAX-W 150 14,2 18,9 510 0,27 0,19 47,3

Alternative Product Name Approval Flame retardance


PAS-W / CCX-WK CE Flame retardant - Not applicable Product Name Initial modulus of Final modulus of Max. DC Resistance Current rating in Max. permisible
elasticity of conductor elasticity of expansion of conductor* air**[A] short circuit current
[N/mm2] conductor [N/mm2] expansion of [Ω/km]

SAX-W 35 61 000 62 500 23x10-6 0,986 200 3,2


Standard
SAX-W 50 61 000 62 500 23x10-6 0,720 245 4,3
EN 50397-1 Covered conductors for overhead lines
IEC 60228 Conductor standard SAX-W 70 61 000 62 500 23x10-6 0,493 310 6,4
SAX-W 95 61 000 62 500 23x10-6 0,363 370 8,6
SAX-W 120 53 000 62 000 23x10-6 0,288 430 11,0
SAX-W 150 53 000 62 000 23x10-6 0,236 485 13,5
Construction
Cable Shape Round
Conductors Watertight aluminium alloy, round, stranded and compacted
Outer Sheath Black weather resistant XLPE compound
Example of marking on sheath Sax-W 70 20 kV DRAKA "Production number", "Date and time", metre marked

Temperature
Maximum operating Temperature 80°C
Temparatures at installation [°C] Lowest cable temperature during installation -20 °C, below 0 °C special precautions are
recommended.

Features
UV resistance Good

Electrical
Max. short circuit temperature [°C] 200ºC

18 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. Data fromin2017-10-09
product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 19
Standard delivery length Delivery Package SAP Number
[m]
Covered overhead lines CCST-39 W 2000 K12 4741532130808 20213314
CCST-62 W 1500 K12 4741532130839 20163991
CCST-W 20 kV CCST-99 W 1000 K12 4741532130846 20159492
CCST-159 W 1000 K14 4741532130860 20163988
CCST-241 W 1000 K18 4741532130884 20163989

Product Name Diameter over Diameter over Weight of cable Min. permissible Min. permissible Min. tensile strength
conductor [mm] covered conductor [kg/km] bending radius bending radius at of the conductor[kN]
[mm] during laying [m] final installation [m]
CCST-39 W 8.1 13.1 225 0.20 0.14 12.2
CCST-62 W 10.1 15.1 309 0.23 0.16 18.64
CCST-99 W 12.8 17.8 449 0.27 0.19 29.22
Application CCST-159 W 16.3 21.3 575 0.32 0.22 43.61
Covered conductor with a semiconductive layer for pole installation. CCST-241 W 20.1 25.1 829 0.38 0.27 61.49

Product Name Initial modulus of Final modulus of Max DC Current Max. permisible
elasticity of conductor elasticity of conductor expansion expansion of Resistance of rating in short circuit
Alternative Product Name Flame retardance Approval [N/mm2] conductor [1/k] conductor* air** [A] current for 1
BLL 20 kV Flame retardant - Not applicable CE sec.*** [kA]
CCST-39 W 64000 78000 19,2 x 10-6 0.848 - 3.7
CCST-62 W 64000 78000 19,2 x 10-6 0.5355 225 5.9
CCST-99 W 64000 78000 19,2 x 10-6 0.3367 310 9.4
Standard CCST-159 W 53000 62000 23 x 10-6 0.1923 440 15.8
SS-EN 50397-1 Construction standard - Covered conductors for overhead lines CCST-241 W 53000 62000 23 x 10-6 0.1265 580 24
IEC 60228 Conductor standard

Construction
Cable Shape Round
Conductors CCST-W 39, 62 & 99: Round stranded aluminium steel reinforced conductor
CCST-W 159 & 241: Round, stranded aluminium steel reinforced conductor
Conductor Insulation Semiconductive compound
Outer Sheath Weather resistant PE, black
Example of marking on sheath CCST- 99W 20 kV DRAKA, "Production number", "Date and time", metre marked

Temperature
Maximum operating Temperature 70 °C.
Temparatures at installation [°C] Lowest temperature -20 °C, below 0 °C extra precaution is recommended.

20 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. Data fromin2017-10-09
product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee
Standard delivery length Delivery Package SAP Number
[m]
Covered overhead lines CCSX 35 AL3 WK 2000 K11 4741532130600 20134348
CCSX 50 AL3 WK 2000 K12 4741532130617 20134349
CCSX AL3 WK 20 kV CCSX 70 AL3 WK 2000 K12 4741532130624 20134350
CCSX 95 AL3 WK 2000 K14 4741532130631 20134351
CCSX 120 AL3 WK 2000 K18 4741532130648 20134352
CCSX 150 AL3 WK 2000 K18 4741532130655 20134353

Product Name Diameter over Diameter over Cable weight Min. permissible Min. permissible Min. tensile strength
conductor [mm] covered conductor [kg/km] bending radius bending radius at of the conductor[kN]
[mm] during laying [m] final installation [m]
CCSX 35 AL3 WK 6.9 12 170 0.18 0.13 11.2
CCSX 50 AL3 WK 8 13.2 220 0.20 0.14 15.5
Application CCSX 70 AL3 WK 9.7 14.8 290 0.22 0.16 22.5
Covered conductor for pole installation. CCSX 95 AL3 WK 11.3 16.5 370 0.25 0.17 30.4
CCSX 120 AL3 WK 12.8 18 455 0.27 0.19 38
CCSX 150 AL3 WK 14.2 19.4 545 0.29 0.20 47.3

Flame retardance
Product Name Initial modulus of Final modulus of elasticity Max DC Current rating Max. permisible
Flame retardant - Not applicable
elasticity of of conductor[N/mm2] expansion expansion Resistance of in air** [A] short circuit
conductor of conductor[1/k] conductor*[Ω/km] current for 1
[N/mm2]
CCSX 35 AL3 WK 61 000 62 500 23x10-6 0.986 200 3.2
Standard CCSX 50 AL3 WK 61 000 62 500 23x10-6 0.72 245 4.3
EN 50397-1 Covered conductors for overhead lines CCSX 70 AL3 WK 61 000 62 500 23x10-6 0.493 310 6.4
IEC 60228 Conductor standard
CCSX 95 AL3 WK 61 000 62 500 23x10-6 0.363 370 8.6
CCSX 120 AL3 WK 61 000 62 500 23x10-6 0.288 430 11
CCSX 150 AL3 WK 61 000 62 500 23x10-6 0.236 485 13.5
*Conductor temperature 20ºC ** Air temperature 25ºC
Construction
Cable Shape Round
Conductors Round, stranded and compacted watertight aluminium alloy conductor
Inner semi-conducting layer Cross-linkable semiconductive compound
Outer Sheath Black weather resistant XLPE compound
Example of marking on sheath CCSX 70 AL3 WK DRAKA "Production number", "Date and time", metre marked

Temperature
Maximum operating Temperature 80 ˚C
Temparatures at installation [°C] -20 ˚C

22 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. Data fromin2017-10-09
product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 23
Product Name Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[m]
Power Cables 1kV AXPK 1x185 1000 K14 4741532130006 20074943
AXPK 1x240 1000 K18 4741532130013 20074944
AXPK 1 core and AXPK-Plus 1 core 0,6/1(1,2) kV AXPK 1x300 1000 K18 4741532130020 20074945
AXPK 1x400 1000 K18 4741532130037 20074946
AXPK 1x500 500 K18 4741532130044 20074947
AXPK 1x630 500 K18 4741532130051 20074948
AXPK 1x800 500 K20 4741532130068 20074949
AXPK 1x1000 500 K22 4741532130075 20074950
AXPK-PLUS 1x300 500 K14 6410006019311 20140296
AXPK-PLUS 1x800 500 K20 6410006019359 20140297

Product Name Conductor weight Cable weight [kg/km] Min.permissible bending Min. permissible
Application Cable diameter [mm] [kg/km] radius during laying [m] bending radius at final
Power cable with round, stranded and compacted aluminium conductor. For fixed installations indoors and outdoors, perfect for ploughing installation [m]
down. Suitable for cable ducts and house connections. AXPK-Plus is the halogen-free version of the cable. AXPK 1x185 24 484 745 0.36 0.26
AXPK 1x240  27 635 940 0.405 0.29
AXPK 1x300 29 795 1150 0.435 0.31
AXPK 1x400 32 1020 1460 0.48 0.34
Alternative Product Name Flame retardance
AXPK 1x500 36 1312 1850 0.54 0.38
AXPK-HF IEC 60332-1-2 - Vertical flame propagation for a
AXPK 1x630 40 1692 2350 0.6 0.42
single insulated wire or cable
AXPK 1x800 44 2160 2950 0.66 0.47
AXPK-PLUS 1X300 29 795 2160 0.435 0.31
AXPK-PLUS 1X800 44 2160 2900 0.66 0.47

Standard
SFS 4879 0.6/1 kV XLPE insulated Al and Cu wires. Product Name Max. permissible pulling force Max. permissible pulling force Max. DC resistance of conductor *
IEC 60502-1 Construction Standard with a pulling grip [kN] with a pulling eye  [kN] [Ω/km]
IEC 60228 Conductor standard
AXPK 1x185 2.7 9.2 0.164
CENELEC HD 603 Part 5 Section D Harmonized construction standard
HD 60364-5-52 Selection and erection of electrical equipment. Wiring systems. AXPK 1x240 3.6 12 0.125
AXPK 1x300 4.5 15 0.1
AXPK 1x400 6 20 0.0778
AXPK 1x500 7 20 0.0605
Construction AXPK 1x630 8.1 20 0.0467
Cable Shape Round. AXPK 1x800 8.5 20 0.0367
Conductors Round, compacted and stranded aluminium conductor. AXPK-PLUS 1X300 4.5 15 0.1
Conductor Insulation Black XLPE compound.
Outer Sheath AXPK - black PVC. AXPK-PLUS 1X800 8.5 20 0.0367
AXPK-Plus - black self-extinguishing halogen-free compound. *Conductor temperature 20ºC    
Example of marking on sheath AXPK-PLUS 1KV DRAKA "Date and time", metre marked.

Temperature Product Name Current rating in Current rating in Current rating in air**  Current rating in air**  Max. permisible short
Maximum operating Temperature 90ºC ground* [A]; flat ground*  [A]; trefoil [A]; flat formation [A]; trefoil formation circuit current for 1
Temparatures at installation [°C] Lowest cable temperature during installation: -20 ºC below 0 ºC extra precaution is formation formation sec.***, kA
recommended.
AXPK 1x185 431 334 500 390 17.5
Features AXPK 1x240 511 397 600 470 22.6
CPR Performance class Eca AXPK 1x300 525 460 690 560 28.3
UV resistance Good. AXPK 1x400 711 558 815 640 37.6
AXPK 1x500 821 647 930 750 47
Electrical
AXPK 1x630 954 754 1110 880 59.2
Max. short circuit temperature [°C] 250ºC
AXPK 1x800 1000 830 1300 1050 75.6
AXPK-PLUS 1X300 525 460 690 555 28.3
AXPK-PLUS 1X800 1000 830 1300 1040 75.6
*Conductor temperature 70ºC     **Conductor temperature 90ºC
*** Initial temperature of conductor before short circuit  90ºC, final temperature of conductor after short circuit  250ºC 
The ratings are based on the following conditions : maximum conductor temperature- 90ºC, ground temperature- 15ºC, air temperature- 25ºC,
 thermal resistivity  of soil- 1,0 ºKm/W, depth of burial-0,7m

24 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 25
Standard delivery length Delivery Package SAP Number
[m]
Power Cables 1kV XPK 1x185 500 K11 4741532120502 20140290
XPK 1x240 500 K12 4741532120519 20180995
XPK 1 core and XPK-Plus 1 core 0,6/1(1,2) kV XPK 1x300 500 K14 4741532120526 20140291
XPK-PLUS 1X185 500 K11 4741532120533
XPK-PLUS 1X300 500 K14 4741532120557

Product Name Conductor weight Cable weight Min. permissible Min. permissible Max. permissible Max. permissible
Cable diameter [kg/km] [kg/km] bending radius bending radius at pulling force with pulling force with
[mm] during laying [m] final installation a pulling grip [kN]
[m]
XPK 1x185 23 1590 1900 0.35 0.24 2.7 18.5
XPK 1x240 26 2115 2400 0.39 0.27 3.6 20
Application XPK 1x300 29 2620 3050 0.44 0.31 4.5 20
Power cable with round, stranded and compacted copper conductor. For fixed installations indoors and outdoors, perfect for ploughing down. XPK-PLUS 1x185 23 1590 1900 0.35 0.24 2.7 18.5
Suitable for cable ducts and house connections. XPK-Plus is the halogen-free version of the cable. XPK-PLUS 1x300 29 2620 3000 0.44 0.31 4.5 20
*Conductor temperature 20ºC

Alternative Product Name Approval Flame retardance Product Name Current rating in Current rating in Current rating in Current rating in Max. permissible Maximum DC
ground* [A]; flat short circuit current resistance of
XPK-HF 1 core CE IEC 60332-1-2 - Vertical flame propagation
for a single insulated wire or cable formation formation formation formation for 1 sec.***, kA conductor * [Ω/km]
XPK 1x185 535 425 645 510 26.4 0.0991
XPK 1x240 625 500 790 610 34.2 0.0745
XPK 1x300 735 585 885 705 42.8 0.0601
XPK-PLUS 1x185 535 425 645 510 26.4 0.0991
Standard
XPK-PLUS 1x300 735 585 885 705 42.8 0.0601
SFS 4879 0.6/1 kV XLPE insulated Al and Cu wires.
IEC 60502-1 Construction Standard *Conductor temperature 70ºC
CENELEC HD 603 Part 5 Section D Harmonized construction standard **Conductor temperature 90ºC
IEC 60228 Conductor standard

The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC

Construction
Cable Shape Round.
Conductors Round, compacted and stranded copper conductor.
Conductor Insulation Black XLPE compound.
Outer Sheath XPK - black PVC.
XPK-PLUS - black self-extinguishing halogen-free compound.
Example of marking on sheath XPK-PLUS ANNEALED 1KV DRAKA "Data ir laikas", ilgio žymuo

Temperature
Maximum operating Temperature 90ºC
Temparatures at installation [°C] Lowest cable temperature during installation: -20 ºC below 0 ºC special precaution shall be
taken.

Features
CPR Performance class Eca
UV resistance Good.

Electrical
Max. short circuit temperature [°C] 250ºC

26 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 27
Product Name Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[m]
AXPK-PLUS 4G16 RE 1000 K12 4741532120106 20079318
AXPK-PLUS 5G16 RE 1000 K12 4741532120120 20097601
AXPK-PLUS 4G16 RM 1000 K12 4741532120090 20079317
AXPK-PLUS 4G25 1000 K14 4741532120137 20076250
Power Cables 1kV AXPK-PLUS 5G25 1000 K14 4741532120281 20163987

AXPK-PLUS 0,6/1(1,2) kV
AXPK-PLUS 4G35 1000 K16 4741532120151 20076251
AXPK-PLUS 5G35 1000 K16 4741532120274 20163932
AXPK-PLUS 4G50 1000 K18 4741532120168 20076252
AXPK-PLUS 4G70 1000 K20 4741532120175 20076253
AXPK-PLUS 4G95 1000 K20 4741532120182 20076254
AXPK-PLUS 4G120 1000 K22 4741532120199 20076255
AXPK-PLUS 4G150 500 K20 4741532120205 20076256
AXPK-PLUS 4G185 500 K22 4741532120212 20076257
AXPK-PLUS 4G240 500 K22 4741532120229 20076258
AXPK-PLUS 4G300 500 K24 4741532120236 20076259

Application Product name Cablediameter[mm] Conductor Min.permissible Min. Max. Max


Power cable with stranded compacted aluminium conductor. The cable is halogen free. For fixed installation indoors and outdoors, perfect for weight[kg/km] bendingradius during permissiblebending permissiblepulling permissiblepulling
ploughing down. Suitable for cable ducts and house connections.
laying [m] radius at final force with apulling force with apulling
installation[m] grip [kN] eye [kN]
AXPK-PLUS 4G16 RE 20 165 0.24 0.17 0.9 3.2
AXPK-PLUS 4G16 RM 20 165 0.24 0.17 0.9 3.2
Flame retardance Approval
AXPK-PLUS 5G16 RE 20 207 0.25 0.18 1.1 4.0
IEC 60332-1-2 - Vertical flame propagation CE
for a single insulated wire or cable AXPK-PLUS 4G25 21 265 0.26 0.19 1.5 5.0
AXPK-PLUS 5G25 25 332 0.31 0.22 1.8 6.2
AXPK-PLUS 4G35 23 365 0.28 0,20 2.1 7.0
AXPK-PLUS 5G35 27 460 0.31 0.23 2.6 8.8
AXPK-PLUS 4G50 27 495 0.31 0.23 3.0 10.1
Standard
AXPK-PLUS 4G70 30 720 0.36 0.26 4.2 14.0
CENELEC HD 308 S2 Identification of cores in cables
IEC 60502-1 Construction Standard AXPK-PLUS 4G95 34 995 0.41 0.29 5.7 19.0
CENELEC HD 603 Part 5 Section D Harmonized construction standard AXPK-PLUS 4G120 38 1260 0.46 0.33 7.2 20.0
HD 60364-5-52 Selection and erection of electrical equipment. Wiring systems.
IEC 60228 Conductor standard AXPK-PLUS 4G150 42 1550 0.51 0.36 8.5 20.0
SFS 4879 0.6/1 kV XLPE insulated Al and Cu wires. AXPK-PLUS 4G185 47 1950 0.57 0.40 8.5 20.0
AXPK-PLUS 4G240 53 2550 0.64 0.45 8.5 20.0
AXPK-PLUS 4G300 58 3190 0.70 0.49 8.5 20.0
*Conductor temperature 20ºC         **Conductor temperature 70ºC, direct burried  
Construction
Cable Shape Round.
Conductors 16 mm² – stranded and compacted or solid round aluminium conductor; Product Name Current rating Current rating Current rating Max. permisibleshort Max. DCresistance Max. ACresistance
25 mm² - stranded, compacted and annealed aluminium conductor; inground* [A], inair* [A] inair** [A] circuit currentfor 1 ofconductor * ofconductor
35–300 mm2 – stranded, compacted and annealed sector shaped aluminium conductor. directburried sec.***, kA [Ω/km] **[Ω/km]
Conductor Insulation XLPE compound.
Marking of cores Phase conductors: brown, black, grey, blue. AXPK-PLUS 4G16 RE 78 64 75 1.5 1.91 2.3
PEN conductor: yellow-green. AXPK-PLUS 4G16 RM 78 64 75 1.5 1.91 2.3
Outer Sheath Black halogen-free self-extinguishing PE compound. AXPK-PLUS 5G16 RE 78 64 75 1.5 1.91 2.3
Example of marking on sheath AXPK-PLUS 1KV 4G16 DRAKA "Date and time", metre marked.
AXPK-PLUS 4G25 100 83 105 2.3 1.20 1.5
Temperature AXPK-PLUS 5G25 100 83 105 2.3 1.20 1.5
Maximum operating Temperature 90ºC AXPK-PLUS 4G35 125 105 130 3.3 0.868 1.0
Temparatures at installation [°C] Lowest cable temperature during installation: -20 ºC below 0 ºC special extra precaution is AXPK-PLUS 5G35 125 105 130 3.3 1.2 1.5
recommended.
AXPK-PLUS 4G50 150 125 165 4,7 0.641 0.77

Features AXPK-PLUS 4G70 185 155 205 6.6 0.443 0.53


CPR Performance class Eca AXPK-PLUS 4G95 220 190 245 8.9 0.320 0.39
UV resistance Good. AXPK-PLUS 4G120 255 220 280 11.3 0.253 0.31
AXPK-PLUS 4G150 290 250 320 14.1 0.206 0.25
Electrical AXPK-PLUS 4G185 330 285 365 17.4 0.164 0.20
Max. short circuit temperature [°C] 250ºC
AXPK-PLUS 4G240 375 330 430 22.6 0.125 0.16
AXPK-PLUS 4G300 430 380 480 28.3 0.100 0.13
*Conductor temperature 70º    **Conductor temperature 90ºC   
***Initial temperature of conductor before short circuit 90ºC, final temperature of conductor after short circuit 250ºC
The ratings are based on the following conditions: maximum conductor temperature- 90ºC, ground temperature-- 15ºC,
air temperature- 25ºC, thermal resistivity of soil- 1,0 ºKm/W, depth of burial- 0,7m.

28 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result We
ofreserve
product development
the right and/or
to change as a result of productchanges
developmentin product
and/or changes standard. Data
in product standard. Datafrom 2017-10-13
from 2017-12-19 drakakeila.ee 29
Product Name Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[m]
Power Cables 1kV AXPK 4G16 RE 1000 K12 4741532130105 20076220
AXPK 4G16 RM 1000 K12 4741532130112 20076221
AXPK 0,6/1(1,2) kV AXPK 5G16 RE 1000 K12 4741532130129 20074980
AXPK 4G25 1000 K14 4741532130136 20076222
AXPK 5G25 1000 K16 4741532130150 20074981
AXPK 4G35 1000 K16 4741532130167 20076224
AXPK 4G50 1000 K16 4741532130181 20076226
AXPK 4G70 1000 K20 4741532130204 20076228
AXPK 4G95 1000 K20 4741532130228 20076230
AXPK 4G120 1000 K22 4741532130235 20076231
AXPK 4G150 500 K20 4741532130259 20076233
AXPK 4G185 500 K20 4741532130266 20076234
Application AXPK 4G240 500 K22 4741532130273 20076235
Power cable with aluminium conductor. For fixed installation indoors and outdoors, perfect for ploughing down. Suitable for cable ducts and AXPK 4G300 500 K24 4741532130280 20076236
house connections.

Product Name Conductor weight Cable weight Min. permissible Min.permissible Max. permisible short
Cable diameter
[kg/km] [kg/km] bending radius bending radius at final circuit current for 1
[mm]
during laying [m] installation [m] sec.***, kA
Approval Flame retardance
AXPK 4G16 RE   20 165 370 0.24 0.17 1.5
CE EN 60332-1-2 - Vertical flame propagation for a
single insulated wire or cable AXPK 4G16 RM   20 165 370 0.24 0.17 1.5
AXPK 5G16 RE   20 207 435 0.25 0.18 1.5
AXPK 4G25   21 265 615 0,26 0,19 2,3
AXPK 5G25   25 332 670 0.31 0.22 2,3
AXPK 4G35   23 365 865 0,28 0,20 3,3
Standard
CENELEC HD 308 S2 Identification of cores in cables AXPK 4G50   27 495 1025 0,31 0,23 4,7
IEC 60502-1 Construction Standard AXPK 4G70   30 720 1400 0,36 0,26 6,6
CENELEC HD 603 Part 5 Section D Harmonized construction standard AXPK 4G95   34 995 1840 0,41 0,29 8,9
IEC 60228 Conductor standard
SFS 4879 0.6/1 kV XLPE insulated Al and Cu wires. AXPK 4G120   38 1260 1900 0,46 0,33 11,3
AXPK 4G150   42 1550 2300 0,51 0,36 14,1
AXPK 4G185   47 1950 2800 0,57 0,4 17,4
AXPK 4G240   53 2550 3700 0,64 0,45 22,6
Construction AXPK 4G300   58 3190 4600 0,7 0,49 28,3
Cable Shape Round. *** Initial temperature of conductor before short circuit  90ºC, final temperature of conductor after short circuit  250ºC 
Conductors 16 mm² – stranded and compacted or solid round aluminium conductor;
25 mm² - stranded, compacted and annealed aluminium conductor;
35–300 mm2 – stranded, compacted and annealed sector shaped aluminium conductor. Product Name Max. permissible Max. permissible Max. DC Max. AC Current rating in Current rating in Current rating in
Conductor Insulation XLPE compound. pulling force with a pulling force with a resistance of resistance of ground* [A], air*  [A] air**  [A]
Marking of cores Phase conductors: brown, black, grey, blue;
PEN conductor: yellow-green. pulling grip [kN] pulling eye  [kN] conductor * conductor ** direct burried
Outer Sheath Black PVC. [Ω/km] [Ω/km]
Example of marking on sheath AXPK 1KV 4G16 DRAKA "Date and time", metre marked. AXPK 4G16 RE   0.9 3.2 1.91 2.3 78 64 75
AXPK 4G16 RM   0.9 3.2 1.91 2.3 78 64 75
Temperature
AXPK 5G16 RE   1.1 4 1.91 2.3 78 64 75
Maximum operating Temperature 90ºC
Temparatures at installation [°C] Lowest cable temperature during installation: -15 ºC below 0 ºC special precaution is AXPK 4G25   1,5 5 1,2 1,5 100 83 105
recommended. AXPK 5G25   1.8 6.2 1,2 1,5 100 83 105
AXPK 4G35   2,1 7 0,868 1.0 125 105 130
Features
AXPK 4G50   3 10 0,641 0,77 150 125 165
CPR Performance class Eca
UV resistance Good. AXPK 4G70   4,2 14 0,443 0,53 185 155 205
AXPK 4G95   5,7 19 0,320 0,39 220 190 245
Electrical AXPK 4G120   7,2 20 0,253 0,31 255 220 280
Max. short circuit temperature [°C] 250 ºC AXPK 4G150   8,5 20 0,206 0,25 290 250 320
AXPK 4G185   8,5 20 0,164 0,2 330 285 365
AXPK 4G240   8,5 20 0,125 0,16 375 330 430
AXPK 4G300   8,5 20 0,125 0,13 430 380 480
*Conductor temperature 20ºC       **Conductor temperature 70ºC
The ratings are based on the following conditions: maximum conductor temperature- 90ºC, ground temperature- 15ºC,
air temperature- 25ºC, thermal resistivity of soil- 1,0 ºKm/W, depth of burial- 0,7m.

30 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 31
Product Name Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[m]
Power Cables 1kV ARLC 4G16 + 2.5Cu 1000 K12 4741532130440 20111654
ARLC 4G25 + 2.5Cu 1000 K14 4741532130457 20076248
ARLC and ARLC-PLUS 0,6/1(1,2) kV ARLC 4G35 + 2.5Cu 500 K14 4741532130464 20076249
ARLC-PLUS 4G16 + 2.5Cu 1000 K12 4741532130471 20112072
ARLC-PLUS 4G25 + 2.5Cu 1000 K14 4741532130488 20164811
ARLC-PLUS 4G35 + 2.5Cu 500 K14 4741532130495 20172988

Product Name Conductor weight Cable weight [kg/km] Min.permissible bending Min.permissible bending
Cable diameter [mm] [kg/km] radius during laying [m] radius at final
installation [m]
ARLC 4G16 + 2.5Cu 18.1 186 380 0.24 0.17
ARLC 4G25 + 2.5Cu 22.6 286 545 0.26 0.19
Application ARLC 4G35 + 2.5Cu 26.1 386 715 0.28 0,20
Road lighting cable with aluminium conductor and copper signal conductor. ARLC-PLUS 4G16 + 2.5Cu 18.1 186 355 0.24 0.17
ARLC-PLUS 4G25 + 2.5Cu 22.6 286 515 0.26 0.19
ARLC-PLUS 4G35 + 2.5Cu 26.1 386 690 0.28 0.20

Alternative Product Name Flame retardance Approval


Product Name Max. permissible pulling Max. permissible pulling Max. DC resistance of Max. AC resistance of
ARLC - HF IEC 60332-1-2 - Vertical flame propagation for a CE
force with a pulling grip [kN] force with a pulling eye  conductor * [Ω/km] conductor ** [Ω/km]
single insulated wire or cable
[kN]
ARLC 4G16 + 2.5Cu 0.9 3.2 1.91 2.3
ARLC 4G25 + 2.5Cu 1.5 5 1.2 1.5
ARLC 4G35 + 2.5Cu 2.1 7 0.868 1.0
Standard ARLC-PLUS 4G16 + 2.5Cu 0.9 3.2 1.91 2.3
IEC 60502-1 Construction Standard
CENELEC HD 308 S2 Identification of cores in cables ARLC-PLUS 4G25 + 2.5Cu 1.5 5 1.2 1.5
CENELEC HD 603 Part 5 Section D Harmonized construction standard ARLC-PLUS 4G35 + 2.5Cu 2.1 7 0.868 1.0
IEC 60228 Conductor standard *Conductor temperature 20ºC      **Conductor temperature 70ºC    

Product Name Current rating in ground* Current rating in air*  [A] Current rating in air**  [A] Max. permisible short
[A], direct burried circuit current for 1 sec.***,
Construction kA
Cable Shape Round.
Conductors 16 mm²: solid round aluminium conductor; ARLC 4G16 + 2.5Cu 78 64 75 1.5
25 mm²: stranded round aluminium conductor; ARLC 4G25 + 2.5Cu 100 83 105 2,3
35 mm²: sector shaped aluminium conductor. ARLC 4G35 + 2.5Cu 125 105 130 3,3
Center conductor 2.5 mm²: solid round insulated copper signal conductor.
Conductor Insulation XLPE. ARLC-PLUS 4G16 + 2.5Cu 78 64 75 1.5
Lay up / Shielding Four insulated conductors stranded together. ARLC-PLUS 4G25 + 2.5Cu 100 83 105 2,3
Marking of cores Phase conductors: brown, black, grey;
PEN conductor: yellow-green; ARLC-PLUS 4G35 + 2.5Cu 125 105 130 3,3
Signal conductor: black. *Conductor temperature 70ºC    **Conductor temperature 90ºC
Outer Sheath ARLC : PVC; *** Initial temperature of conductor before short circuit  90ºC, final temperature of conductor after short circuit  250ºC 
ARLC - Plus: black self-extinguishing halogen-free compound.
Example of marking on sheath ARLC DRAKA "Data ir laikas", ilgio žymuo The ratings are based on the following conditions: maximum conductor temperature - 90ºC, ground temperature - 15ºC,  
air temperature - 25ºC, thermal resistivity  of soil - 1,0 ºKm/W, depth of burial - 0,7m
Temperature
Maximum operating Temperature 90ºC
Temparatures at installation [°C] Žemiausia rekomenduojama temperatūra montuojant: ARLC -15 ºC, žemiau 0 ºC
rekomenduojama imtis atsargumo priemonių; ARLC-PLUS -20 ºC, žemiau 0 ºC
rekomenduojama imtis atsargumo priemonių.

Features
UV resistance Good.

Electrical
Max. short circuit temperature [°C] 250ºC

32 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 33
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 1x50/16 500 K11 7330384710664 20102173
1x70/16 500 K11 7330384713948 20113259
AXLJ -TTCL TSLF 6/10(12) kV 1x95/25 500 K12 7330384710671 20102174
1x120/25 500 K12 7330384713955 20113260
1x150/25 500 K12 7330384710688 20040268
1x185/35 500 K14 7330384713962 20113271
1x240/35 500 K14 7330384708920 20078241
1x300/35 500 K16 7330384713979 20113272
1x400/35 500 K16 7330384709651 20102175
1x500/35 500 K18 7330384713986 20113273
1x630/35 500 K20 7330384709316 20102176
1x800/50 500 K20 7330384713993 20113274
Application 1x1000/50 500 K24 7330384722049 20227891
Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before,
during and after installation. Ripcords for easier and safer stripping of the outer sheath. Conductors and screen Conductor Screen resistance* Inductance in trefoil/in Reactance Capacitance Charging current/ Earth fault
area [mm2]  resistance Ω/km  Ω/km  flat* mH/km  Ω/km  µF/km  phase A/km current A/km
1x50/16 0,641 1,15 0,41/0,73 0,23 0,23 0,4 1,3
1x70/16 0,443 1,15 0,38/0,69 0,22 0,28 0,5 1,6
Alternative Product Name Flame retardance Environmental 1x95/25 0,320 0,727 0,36/0,66 0,21 0,32 0,6 1,8
SE-N10XC7A5T5E-AR Flame retardant - Not applicable Enviromantal Declaration - AXLJ-TTCL 1x120/25 0,253 0,727 0,35/0,64 0,20 0,35 0,7 2,0
1x150/25 0,206 0,727 0,34/0,62 0,20 0,38 0,7 2,1
1x185/25 0,164 0,524 0,32/0,61 0,20 0,41 0,8 2,3
1x240/35 0,125 0,524 0,31/0,58 0,18 0,46 0,9 2,6
Standard 1x300/35 0,100 0,524 0,30/0,56 0,18 0,51 1,0 2,9
SS 424 14 16 Construction standard 12-36 kV 1x400/35 0,0778 0,524 0,29/0,54 0,17 0,58 1,1 3,3
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard 1x500/35 0,0605 0,254 0,28/0,52 0,16 0,64 1,2 3,6
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
1x630/35 0,0469 0,524 0,28/0,51 0,16 0,72 1,4 4,1
1x800/50 0,0367 0,387 0,27/0,49 0,15 0,70 1,5 4,5
1x1000/50 0,0291 0,387 0,27/0,48 0,15 0,83 1,6 4,7
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
Construction
Cable Shape Round
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
Inner semi-conducting layer Extruded area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded *A  initial temp. 65ºC kA initial temp. 90ºC kA
Longitudinal water tightness Semi conducting water blocking tape 1x50/16 155 160 195 5,2 4,7
Shield / Screen Annealed copper wires in contact with aluminium tape
Radial water blocking Aluminum-PE laminate, bonded to sheath 1x70/16 200 190 235 7,2 6,6
Ripcord Aramid 1x95/25 235 230 280 9,9 8,9
Outer Sheath PE, natural UV-protected 1x120/25 265 265 325 12,4 11,3
Example of marking on sheath AXLJ-TTCL TSLF 12kV 1x50 AFR/16 DRAKA "Date and time", metre marked
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing) 1x150/25 300 300 370 15,6 14,2
1x185/35 330 345 425 19,2 17,5
Temperature 1x240/35 385 400 490 25,0 22,7
Maximum operating Temperature 90 ºC 1x300/35 435 465 565 31,2 28,3
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken. 1x400/35 510 555 680 41,6 37,8
1x500/35 570 635 775 52,0 47,2
Features 1x630/35 635 720 880 65,6 59,5
Bending radius In fixed installation: 10 x D 1x800/50 695 822 1010 83,2 75,6
When pulling-in: 15 x D
1x1000/50 760 920 1130 103,7 94,5
When plowing down: 8 x D
* Trefoil with screen grounded in both end.
Electrical The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Impulse voltage [kV] 75 kV of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

34 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 35
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 1x50/16 500 K11 7330384720878 20218299
1x70/16 500 K11 7330384720885 20218300
AXQJ-TT Pure TSLI 6/10(12) kV 1x95/25 500 K12 7330384720892 20218371
1x120/25 500 K12 7330384720908 20218372
1x150/25 500 K12 7330384720915 20218373
1x185/25 500 K14 7330384720922 20218374
1x240/35 500 K14 7330384720939 20218375
1x300/35 500 K16 7330384720946 20218376
1x400/35 500 K16 7330384720953 20218377
1x500/35 500 K18 7330384720960 20218378
1x630/35 500 K20 7330384720977 20218379
1x800/50 500 K20 7330384720984 20218380
Application
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and Conductors and Conductor Screen Inductance in Reactance in Capacitance Charging current/ Earth fault
not harmful to electronic equipment. Radial and longitudinal water sealed distribution cable for use indoors and outdoors for 3-phase
screen area [mm2]  resistance Ω/km  resistance* trefoil/in flat* trefoil/in flat* µF/km  phase A/km current A/km
formation. Installation in pipes and ground. Ploughing down is not recommended. Ripcords for easier and safer stripping of the outer sheath.
Ω/km  mH/km  Ω/km 
1x50/16 0,641 1,15 0,40/0,72 0,13/0,23 0,25 0,5 1,4
1x70/16 0,443 1,15 0,37/0,69 0,12/0,22 0,28 0,5 1,6
Alternative Product Name Environmental 1x95/25 0,320 0,727 0,36/0,66 0,11/0,21 0,32 0,6 1,8
SE-N10XC7A5Z1-AR Enviromantal Declaration - AXQJ-TT Pure TSLI 1x120/25 0,253 0,727 0,34/0,64 0,11/0,20 0,35 0,7 2,0
1x150/25 0,206 0,727 0,33/0,62 0,10/0,20 0,38 0,7 2,1
1x185/25 0,164 0,727 0,32/0,60 0,10/0,19 0,41 0,8 2,3
1x240/35 0,125 0,524 0,31/0,58 0,10/0,18 0,46 0,9 2,6
Standard 1x300/35 0,100 0,524 0,30/0,59 0,09/0,17 0,50 1,0 3,0
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 1x400/35 0,0778 0,524 0,29/0,54 0,09/0,17 0,57 1,1 3,3
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard 1x500/35 0,0605 0,524 0,28/0,52 0,09/0,16 0,58 1,1 3,3
CENELEC HD 604 Halogen free material
SS-EN 60754-1, -2 Corrosive gases 1x630/35 0,0469 0,524 0,27/0,50 0,09/0,16 0,64 1,2 3,6
SS-EN 61034-1, -2 Smoke density 1x800/50 0,0367 0,387 0,27/0,49 0,09/0,15 0,79 1,5 4,5
EN 50575:2014 Power, control and communication cables - Cables for general applications in construction * Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
works subject to reaction to fire requirements

Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
*A  initial temp. 65ºC kA initial temp. 90ºC kA
Construction
Cable Shape Round 1x50/16 155 160 195 5,2 4,7
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed 1x70/25 200 190 235 7,2 6,6
Inner semi-conducting layer Extruded 1x95/25 235 230 280 9,9 8,9
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded 1x120/25 265 265 325 12,4 11,3
Longitudinal water tightness Semi conducting water blocking tape 1x150/25 300 300 370 15,6 14,2
Shield / Screen Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminium laminate bonded to the sheath 1x185/25 330 345 425 19,2 17,5
Ripcord Aramid 1x240/35 385 400 490 25,0 22,7
Outer Sheath Halogen free compound, black 1x300/35 435 460 565 31,0 28,3
Example of marking on sheath AXQJ-TT Pure TSLI 12kV 1x240 AFR/35 D-s2d2a2 DRAKA "Date and time", metre marked
1x400/35 510 555 680 41,6 37,8
Temperature 1x500/35 570 635 775 52,0 47,2
Maximum operating Temperature 90 ºC 1x630/35 635 720 880 65,6 59,5
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be 1x800/50 695 822 1010 83,2 75,6
taken.
* Trefoil with screen grounded in both end.
Features The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
CPR Performance class Dca-s2d2a2 of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 75 kV

36 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 37
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x1x50/16 500 K20 7330384709057 20087880
3x1x70/16 500 K20 7330384721851 20114706
AXLJ -TTCL TSLF Triplex 6/10(12) kV 3x1x95/25 500 K22 7330384721868 20114707
3x1x120/25 500 K22 7330384721875 20114708
3x1x150/25 500 K24 7330384721882 20114709
3x1x185/35 500 K24 7330384721899 20114710
3x1x240/35 500 K26 7330384709002 20102177
3x1x300/35 500 K26 7330384721905 20114711
3x1x400/35 500 K28 7330384721912 20114712
3x1x500/35 500 K28 7330384721929 20114713

Conductors and screen Conductor Screen resistance* Inductance Reactance Capacitance Charging current/ Earth fault
Application area [mm2]  resistance Ω/km  Ω/km  mH/km  Ω/km  µF/km  phase A/km current A/km
Single-core, distribution cable for outdoor use in triplex formation. Installation in pipes and ground/water. Both radial and longitudinal water 3x1x50/16 0,641 1,15 0,40 0,13 0,25 0,5 1,4
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before,
3x1x70/16 0,443 1,15 0,38 0,12 0,28 0,5 1,6
during and after installation. Ripcords for easier and safer stripping of the outer sheath.
3x1x95/25 0,320 0,727 0,36 0,11 0,32 0,6 1,8
3x1x120/25 0,253 0,727 0,35 0,11 0,35 0,7 2,0
3x1x150/25 0,206 0,727 0,34 0,11 0,38 0,7 2,1
Alternative Product Name Flame retardance Environmental 3x1x185/35 0,164 0,524 0,32 0,10 0,41 0,8 2,3
SE-N10XC7A5T5E-AR Flame retardant - Not applicable Enviromantal Declaration - AXLJ-TTCL 3x1x240/35 0,125 0,524 0,31 0,10 0,46 0,9 2,6
3x1x300/35 0,100 0,524 0,30 0,09 0,51 1,0 2,9
3x1x400/35 0,0778 0,524 0,29 0,09 0,58 1,1 3,3
3x1x500/35 0,0605 0,524 0,28 0,09 0,64 1,2 3,6
Standard *Note screen resistance is the sum of copper wires and aluminum tape.
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
*A  initial temp. 65ºC kA initial temp. 90ºC kA
3x1x50/16 155 160 195 5,2 4,7
Construction 3x1x70/16 200 190 235 7,2 6,6
Cable Shape Round
Conductors Stranded, round, compacted aluminium acc. to IEC 60228 class 2, longitudinally watertight 3x1x95/25 235 230 280 9,9 8,9
Inner semi-conducting layer Extruded 3x1x120/25 265 265 325 12,4 11,3
Conductor Insulation XLPE, min. thickness = 2,96 mm 3x1x150/25 300 300 370 15,6 14,2
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape 3x1x185/35 330 345 425 19,2 17,5
Shield / Screen Annealed copper wires in contact with aluminum tape 3x1x240/35 385 400 490 25,0 22,7
Radial water blocking Aluminum-PE laminate, bonded to sheath
3x1x300/35 435 460 565 31,2 28,3
Ripcord Aramid
Outer Sheath PE, natural UV-protected 3x1x400/35 510 555 680 41,6 37,8
Example of marking on sheath AXLJ-TTCL TSLF 12kV 1x240 AFR/35 DRAKA "Date and time", metre marked 3x1x500/35 570 635 775 52,0 47,2
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing)
* Trefoil with screen grounded in both end.
Temperature The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Maximum operating Temperature 90 ºC of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 75 kV

38 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 39
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x1x50/16 500 K20 7330384720991 20218381
3x1x70/16 500 K20 7330384721004 20218382
AXQJ-TT Pure TSLI Triplex 6/10(12) kV 3x1x95/25 500 K22 7330384721011 20218383
3x1x120/25 500 K24 7330384721028 20218384
3x1x150/25 500 K24 7330384721035 20218385
3x1x185/35 500 K24 7330384721042 20218386
3x1x240/35 500 K24 7330384721059 20218387
3x1x300/35 500 K26 7330384721066 20218388
3x1x400/35 500 K28 7330384721073 20218389
3x1x500/35 500 K28 7330384721080 20218390

Conductors and Conductor Screen Inductance in Reactance in Capacitance Charging current/ Earth fault
Application screen area [mm2]  resistance Ω/km  resistance* trefoil/in flat* trefoil/in flat* µF/km  phase A/km current A/km
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and Ω/km  mH/km  Ω/km 
not harmful to electronic equipment. Radial and longitudinal water sealed distribution cable for use indoors and outdoors for 3-phase 1x50/16 0,641 1,15 0,40/0,72 0,13/0,23 0,25 0,5 1,4
formation. Installation in pipes and ground. Ploughing down is not recommended. Ripcords for easier and safer stripping of the outer sheath.
1x95/25 0,320 0,727 0,36/0,66 0,11/0,21 0,32 0,6 1,8
1x150/25 0,206 0,727 0,33/0,62 0,10/0,20 0,38 0,7 2,1
1x240/35 0,125 0,524 0,31/0,58 0,10/0,18 0,46 0,9 2,6
Alternative Product Name Environmental 1x400/35 0,0778 0,524 0,29/0,54 0,09/0,17 0,57 1,1 3,3
SE-N10XC7A5Z1-AR Enviromantal Declaration - AXQJ-TT Pure TSLI 1x500/35 0,0605 0,524 0,28/0,52 0,09/0,16 0,58 1,1 3,3
1x630/35 0,0469 0,524 0,27/0,50 0,09/0,16 0,64 1,2 3,6
1x800/50 0,0367 0,387 0,27/0,49 0,09/0,15 0,79 1,5 4,5
1x1000/50 0,0291 0,387 0,27/0,48 0,09/0,15 0,83 1,6 4,7

Standard * Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard
Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
CENELEC HD 604 Halogen free material
SS-EN 60754-1, -2 Corrosive gases area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
SS-EN 61034-1, -2 Smoke density *A  initial temp. 65ºC kA initial temp. 90ºC kA
EN 50575:2014 Power, control and communication cables - Cables for general applications in construction
1x50/16 155 160 195 5,2 4,7
works subject to reaction to fire requirements
1x95/25 235 230 280 9,9 8,9
1x150/25 300 300 370 15,6 14,2
1x240/35 385 400 490 25,0 22,7
1x400/35 510 555 680 41,6 37,8
Construction
Cable Shape Round 1x500/35 570 635 775 52,0 47,2
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed 1x630/35 635 720 880 65,6 59,5
Inner semi-conducting layer Extruded 1x800/50 695 822 1010 83,2 75,6
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded 1x1000/50 760 920 1130 103,7 94,5
Longitudinal water tightness Semi conducting water blocking tape * Trefoil with screen grounded in both end.
Shield / Screen Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminium laminate bonded to the sheath The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Ripcord Aramid of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Outer Sheath Halogen free compound, black
Example of marking on sheath AXQJ-TT Pure TSLI 12kV 1x240 AFR/35 D-s2d2a2 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
CPR Performance class Dca-s2d2a2
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 75 kV

40 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 41
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x50AL+35CU 500 K20 7330384715218 20118178
3x70AL+35CU 500 K22 7330384715225 20118179
AHXAMK-W 6/10(12) kV 3x95AL+35CU 500 K24 7330384710374 20088773
3x120AL+35CU 500 K24 4705554 20078178
3x150AL+35CU 500 K24 7330384707695 20102199
3x185AL+35CU 500 K24 7330384705783 20102200
3x240AL+35CU 500 K26 7330384705578 20102201
3x300AL+35CU 500 K26 7330384709507 20102202

Conductors and screen Conductor resistance Centre conductor Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  resistance Ω/km mH/km  Ω/km  µF/km  phase A/km current
A/km
Application 3x50AL+35CU 0,641 0,524 0,40 0,13 0,25 0,5 1,4
AHXAMK-W (Wiski™) is a assembled from 3-single core cables wrapped around a compact copper conductor. Each cable is radial and 3x70AL+35CU 0,443 0,524 0,38 0,12 0,28 0,5 1,6
longitudinal water sealed. For fixed outdoor installation, can be ploughed down. 3x95AL+35CU 0,320 0,524 0,36 0,11 0,32 0,6 1,8
3x120AL+35CU 0,253 0,524 0,35 0,11 0,34 0,6 1,9
3x150AL+35CU 0,206 0,524 0,34 0,11 0,38 0,7 2,1
3x185AL+35CU 0,164 0,524 0,32 0,10 0,41 0,8 2,3
Alternative Product Name Flame retardance Environmental
3x240AL+35CU 0,125 0,524 0,31 0,10 0,46 0,9 2,6
FI-N10XA4EC-AR Flame retardant - Not applicable Environmental declaration - AHXAMK-W
3x300AL+35CU 0,100 0,524 0,30 0,09 0,51 1,0 2,9

Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
Standard
*A  initial temp. 65ºC kA initial temp. 90ºC kA
CENELEC HD 620 Part 10 Section F Harmonized Construction Standard
3x50AL+35CU 155 160 195 5,2 4,7
3x70AL+35CU 200 190 235 7,2 6,6
3x95AL+35CU 235 230 280 9,9 8,9
3x120AL+35CU 265 265 325 12,4 11,3
Construction
Cable Shape Round 3x150AL+35CU 300 300 370 15,6 14,2
Conductors Stranded, round, compacted aluminium acc. to IEC 60228 class 2, longitudinally watertight 3x185AL+35CU 330 345 425 19,2 17,5
Inner semi-conducting layer Extruded 3x240AL+35CU 385 400 490 25,0 22,7
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded 3x300AL+35CU 435 460 565 31,2 28,3
Longitudinal water tightness Semi conducting water blocking tape * Trefoil with screen grounded in both end.
Core assembly The cores are wrapped around a compact copper conductor. Stranded, round and compacted
copper acc. IEC 60228 class 2 The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Radial water blocking Aluminum-PE laminate, bonded to sheath of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Outer Sheath PE, black
Example of marking on sheath AHXAMK-W 6/10 kV 3x150Al+35Cu DRAKA Phase 1 + "Date and time", 1 core is metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 75 kV

42 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 43
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x50/16 500 K18 7330384701129 20078179
3x95/25 500 K20 7330384701143 20095493
AXLJ -RMF 6/10(12) kV 3x150/25 500 K22 7330384701068 20078182
3x240/35 500 K24 7330384701099 20087130
3x300/35 500 K26 7330384715065 20118045

Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
3x50/16 0,641 1,2 0,33 0,10 0,25 0,5 1,4
3x95/25 0,320 0,8 0,30 0,09 0,32 0,6 1,8
3x150/25 0,206 0,8 0,28 0,09 0,38 0,7 2,0
3x240/35 0,125 0,6 0,23 0,09 0,46 0,8 2,5
Application 3x300/35 0,100 0,6 0,26 0,08 0,51 1,0 2,9
AXLJ-RMF is a 3-core cable designed for replacement of bare overhead lines. Primary developed to be ploughed down but thanks to the robust
design the cable can stand the stresses that appears when laid in water with moderate currents and limited depth. Ripcords for easier and safer
stripping of the outer sheath. Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
screen area core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp. during 1s at initial temp.
65ºC kA 90ºC kA
Alternative Product Name Flame retardance Environmental 3x50/16 145 130 160 5,2 4,7 55
SE-N10XC7E-AR Flame retardant - Not applicable Enviromantal Declaration - AXLJ-F, -RMF 3x95/25 205 190 230 9,9 8,9 65
LT 3x150/25 260 250 305 15,6 14,2 70
3x240/35 340 330 400 25,0 22,7 70
3x300/35 380 375 460 31,2 28,3 70
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Standard of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
SS 424 14 16 Construction standard 12-36 kV
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
IEC 60502-2 Construction standard

Construction
Cable Shape Triangular
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded
Inner covering Conductive tape
Shield / Screen Annealed copper wires
Ripcord Aramid
Outer Sheath Composite PE, Black
Example of marking on sheath AXLJ-RMF 12kV 3x150/25 LT DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Fire Propagation Cable is not flame retardant.
UV resistance Good
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D
Min. Bending radius at final installation 8 xD
Min. Bending radius at during installation 12 xD

Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 75 kV.

44 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 45
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x50/16 500 K18 7330384720113 20203881
3x70/16 500 K18 7330384720120 20203882
AXQJ-RMF Pure 6/10(12) kV 3x95/25 500 K20 7330384720137 20203883
3x120/25 500 K20 7330384720144 20203884
3x150/25 500 K22 7330384720151 20203885
3x185/35 500 K24 7330384720175 20203886
3x240/35 500 K24 7330384720182 20203887
3x300/35 500 K24 7330384720212 20203888

Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
3x50/16 0,641 1,2 0,34 0,11 0,23 0,5 1,4
Application 3x70/16 0,433 1,2 0,31 0,10 0,28 0,5 1,6
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and 3x95/25 0,320 0,8 0,31 0,10 0,30 0,6 1,8
not harmful to electronic equipment. The cable is primarily designed for indoor installation, tunnels, etc. The cable can be installed outdoors 3x120/25 0,253 0,8 0,29 0,09 0,35 0,7 2,0
and in ground but ploughing is not recommended. Ripcords for easier and safer stripping of the outer sheath.
3x150/25 0,206 0,8 0,29 0,09 0,35 0,7 2,0
3x185/35 0,164 0,6 0,27 0,09 0,41 0,8 2,3
3x240/35 0,125 0,6 0,27 0,09 0,43 0,8 2,5
Alternative Product Name Environmental 3x300/35 0,100 0,6 0,26 0,08 0,51 1,0 2,9
SE-N10XC7Z1-AR Environmental Declaration - AXQJ-RMF Pure
Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
screen area core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp. during 1s at initial temp.
Standard 65ºC kA 90ºC kA
SS 424 14 16 Construction standard 12-36 kV 3x50/16 145 130 160 5,2 4,7 55
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 3x70/16 175 155 190 7,2 6,6 60
IEC 60502-2 Construction standard
CENELEC HD 604 Halogen free material 3x95/25 205 190 230 9,9 8,9 65
SS-EN 60754-1, -2 Corrosive gases 3x120/25 230 220 265 12,4 11,3 65
SS-EN 61034-1, -2 Smoke density 3x150/25 260 250 305 15,6 14,2 70
EN 50575:2014 Power, control and communication cables - Cables for general applications in construction
works subject to reaction to fire requirements 3x185/35 290 280 340 19,2 17,5 70
3x240/35 340 330 400 25,0 22,7 70
3x300/35 380 375 460 31,2 29,8 70
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Construction of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Cable Shape Triangular
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded
Inner covering Conductive tape
Shield / Screen Annealed copper wires
Ripcord Aramid
Outer Sheath Halogen free compound, black
Example of marking on sheath AXQJ-RMF Pure 12kV 3x50/16 LT B2-s1d0a2 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
CPR Performance class B2ca-s1d0a2
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D

Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 75 kV.

46 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 47
Electrical
Max. short circuit temperature [°C] 250°C
Impulse voltage [kV] 75 kV

Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x50/16 500 K18 7330384721783 20206411

AXCLJ -TT 6/10(12) kV


3x70/16 500 K20 20206412
3x95/25 500 K20 7330384721776 20206413
3x120/16 500 K22 CA.812373200001
3x150/25 500 K24 7330384721769 20206415
3x185/35 500 K24 20206416
3x240/25 500 K24 CA.812373230001
3x240/35 500 K24 20206417-5
3x300/35 500 K26 20206418

Conductors and Conductor Screen Inductance Reactance Capacitance Zero sequence Charging Earth fault
screen area resistance Ω/km  resistance*  mH/km  Ω/km  µF/km  impedance Z0 current/ current
Application [mm2]  Ω/km  Ω/km phase A/km A/km
AXCLJ-TT is just as AXALJ-TT totally water sealed. Radial water sealed by an aluminum laminate bonded to outer sheath and longitudinally water 3x50/16 0,641 1,2 0,33 0,10 0,25 1,31+j0,87 0,5 1,4
sealed with swellable tapes. The screen is made up of circular copper wires like AXALJ-TT, water blocking tapes (replacing water blocking yarns)
3x70/16 0,443 1,2 0,31 0,10 0,28 1,06+j0,84 0,5 1,6
and the cable has been complemented with two strong ripcords for easier and safer opening of the outer sheath. The cable is primarily designed
for ploughing down in ground, but thanks to its robust design can handle the stresses resulting from installation in lakes with limited currents 3x95/25 0,320 0,8 0,30 0,09 0,32 0,92+j0,72 0,6 1,8
and of limited depth. 3x120/25 0,253 0,8 0,28 0,09 0,35 0,83+j0,70 0,7 2,0
3x150/25 0,206 0,8 0,28 0,09 0,38 0,76+j0,68  0,7 2,1
3x185/35 0,164 0,6 0,27 0,09 0,41 0,71+j0,58 0,8 2,3
3x240/35 0,125 0,6 0,26  0,08 0,46 0,65+j0,56 0,9 2,6
Alternative Product Name Feature
3x300/35 0,100 0,6 0,26 0,08 0,51 0,61+j0,55 1,0 2,9
SE-N10XC7A5T5E-AR The corresponding options with aluminum
*Note! Screen resistance is the sum of copper wires and aluminum tape. The screen cross-section is made up of 60% copper.
screen. - AXALJ-TT
Flame retardance
Flame retardant - Not applicable Environmental Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max. short circuit Max impulse current
Environmental declaration - AXCLJ-TT screen area core temp. 65ºC core temp. 65ºC core temp. 90ºC current on the current on the current on the screen kA
[mm2]   in ground A  in air A  in air A   conductor during 1s conductor during 1s during 1s kA 
at initial temp. 65ºC at initial temp. 90ºC
kA kA
Standard 3x50/16 145 130 160 5,2 4,7 3,2 55
SS 424 14 16 Construction standard 12-36 kV 3x70/16 175 155 190 7,2 6,6 3,2 60
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 3x95/25 205 190 230 9,9 8,9 5 65
3x120/25 230 220 265 12,4 11,3 5 65
3x150/25 260 250 305 15,6 14,2 5 70
3x185/35 290 280 340 19,2 17,5 7 70
Construction 3x240/35 340 330 400 25,0 22,7 7 70
Cable Shape Triangular
3x300/35 380 375 460 31,2 28,3 7 70
Conductors Stranded, round, compacted aluminum acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Conductor Insulation XLPE, min. thickness = 2,96 mm of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Filler PE-profiles
Inner covering Conductive tape
Shield / Screen Round copper wires in contact with aluminum laminate
Radial water blocking Aluminum-PE laminate, bonded to sheath
Ripcord Aramid
Outer Sheath Composite PE, Black
Example of marking on sheath AXCLJ-TT 12kV 3x50/16 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D
Max Pulling force - pulling grip [N/mm2] Max. pulling forse = 5 x D ^ 2 (N)
D = outer diameter of cable (mm)
Max Pulling force - pulling eye [N/mm2] Max. pulling forse = 30 x S (N)
S = cross-sectional area of conductor (mm^2)
We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-16

48 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 49
Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 75 kV
Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 75 kV

Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x25/25 AL 500 K16 20158257
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
AXALJ -TT 6/10(12) kV
3x50/25 AL 500 K18 7330384717014 20151640
[mm2] [m]
3x70/25 AL 500 K20 7330384717021 20151641
3x25/25 AL
3x95/35 AL 500
500 K16
K20 7330384717038 20158257
20151642
3x50/25
3x120/35AL
AL 500
500 K18
K22 7330384717014
7330384717045 20151640
20151643
3x70/25 AL
3x150/35 AL 500
500 K20
K24 7330384717021
7330384717052 20151641
20151644
3x95/35
3x185/50AL
AL 500
500 K20
K24 7330384717038
7330384717069 20151642
20151645
3x120/35 AL
3x240/50 AL 500
500 K22
K24 7330384717045
7330384717076 20151643
20151646
3x150/35
3x300/50 AL
AL 500
500 K24
K26 7330384717052
7330384717144 20151644
20152032
3x185/50 AL 500 K24 7330384717069 20151645
3x240/50 AL 500 K24 7330384717076 20151646
Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
3x300/50 AL 500 K26 7330384717144 20152032
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
Application 3x25/25 AL 1,20 1,2 0,36 0,11 0,20 0,4 1,1
AXALJ-TT is just like its predecessor AXLJ-TT, totally water sealed. Radially water sealed by an aluminium laminate bonded to the outer sheath Conductors
3x50/25 AL and screen Conductor resistance
0,641 Screen resistance
1,2 Inductance
0,33 Reactance
0,10 Capacitance
0,25 Charging current/
0,5 Earth fault
1,4
longitudinally water sealed with swellable tapes. The screen is made up of circular aluminium wires, water blocking tapes (replacing the water area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
swellable yarns) and the cable has been complemented with two strong ripcords for easier and safer opening of the outer sheath. The cable is 3x75/25 AL 0,443 1,2 0,31 0,10 0,28 0,5 1,6
primarily designed for ploughing down in ground, but thanks to its robust design can handle the stresses resulting from installation in lakes 3x25/25 AL
3x95/35 AL 1,20
0,320 1,2
0,8 0,36
0,30 0,11
0,09 0,20
0,32 0,4
0,6 1,1
1,8
with limited currents and of limited depth. 3x50/25
3x120/35AL
AL 0,641
0,253 1,2
0,8 0,33
0,28 0,10
0,09 0,25
0,35 0,5
0,7 1,4
2,0
3x75/25
3x150/35AL
AL 0,443
0,206 1,2
0,8 0,31
0,28 0,10
0,09 0,28
0,38 0,5
0,7 1,6
2,1
3x95/35
3x185/50AL
AL 0,320
0,164 0,8
0,6 0,30
0,27 0,09
0,09 0,32
0,41 0,6
0,8 1,8
2,3
3x120/35
3x240/50 AL
AL 0,253
0,125 0,8
0,6 0,28
0,26 0,09
0,08 0,35
0,46 0,7
0,9 2,0
2,6
Alternative Product Name Flame retardance Environmental
3x150/35
3x300/50 AL
AL 0,206
0,0778 0,8
0,6 0,28
0,26 0,09
0,08 0,38
0,51 0,7
1,0 2,1
2,9
SE-N10XA5E-AR Flame retardant - Not applicable Enviromantal Declaration - AXALJ-TT
3x185/50 AL 0,164 0,6 0,27 0,09 0,41 0,8 2,3
3x240/50 AL 0,125 0,6 0,26 0,08 0,46 0,9 2,6
Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
3x300/50 AL 0,0778 0,6 0,26 0,08 0,51 1,0 2,9
screen area current on the conductor
core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp.
during 1s at initial temp.
Standard
Conductors and Current rating at Current rating at Current rating at 65ºC
Max.kA
short circuit 90ºC
Max. kA
short circuit Max impulse current kA
SS 424 14 16 Construction standard 12-36 kV
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard screen area
3x25/25 AL core
100 temp. 65ºC in core
90 temp. 65ºC in core
110 temp. 90ºC in current
2,6 on the conductor current
2,3 on the conductor -
[mm2]   AL
3x50/25 ground
145 A  air
130A  air
160A   during
5,2 1s at initial temp. during
4,7 1s at initial temp. 55
3x70/25 AL 175 155 190 65ºC
7,2 kA 90ºC
6,6 kA 60
3x25/25
3x95/35 AL
AL 100
205 90
190 110
230 2,6
9,9 2,3
8,9 -65

Construction 3x50/25
3x120/35AL
AL 145
230 130
220 160
265 5,2
12,4 4,7
11,3 55
65
Cable Shape Triangular 3x70/25
3x150/35AL
AL 175
260 155
250 190
305 7,2
15,6 6,6
14,2 60
70
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed 3x95/35
3x185/50AL
AL 205
290 190
280 230
340 9,9
19,2 8,9
17,5 65
70
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 2,96 mm 3x120/35
3x240/50 AL
AL 230
340 220
330 265
400 12,4
25,0 11,3
22,7 65
70
Outer semi-conducting layer Bonded 3x150/35
3x300/50 AL
AL 260
380 250
375 305
460 15,6
31,2 14,2
28,3 70
70
Longitudinal water tightness Semi conducting water blocking tape
Filler PE-profiles The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature70
3x185/50 AL 290 280 340 19,2 17,5 25ºC –thermal resistivity
Shield / Screen Round aluminium wires in contact with aluminium laminate 3x240/50
of AL
soil 1,0 ºKm/W 340 of burial 0,65 m
–depth 330
–frequency 50Hz 400 25,0 22,7 70
Radial water blocking Aluminium laminate bonded to the sheath 3x300/50 AL 380 375 460 31,2 28,3 70
Ripcord Aramid
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Outer Sheath Composite PE, black
Example of marking on sheath AXALJ-TT 12kV 3x50/25 AL DRAKA "Date and time", metre marked of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D
Max Pulling force - pulling grip [N/mm2] Max pulling force = 5 x D^2 (N)
D = outer diameter of the cable (mm)
Max Pulling force - pulling eye [N/mm2] Max pulling force = 30 x S (N)
S = cross-sectional area of the conductor (mm^2)

We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-16

50 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13
We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-16
We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 51
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 3x35/16 500 K16 7330384714761 20117462
3x50/16 500 K18 7330384714778 20117463
FXLJ -TT 6/10(12) kV 3x70/16 500 K18 7330384714785 20117464
3x95/25 500 K20 7330384714792 20117465
3x120/25 500 K20 7330384714808 20117491
3x150/25 500 K22 7330384714815 20117497
3x185/35 500 K22 7330384714822 20117513
3x240/35 500 K24 7330384714839 20117514

Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
3x35/16 0,524 1,2 0,34 0,11 0,22 0,4 1,2
Application 3x50/16 0,387 1,2 0,33 0,10 0,25 0,5 1,4
FXLJ-TT is a three core cable primary developed to be ploughed down but thanks to the robust design the cable can withstand the stress that 3x70/16 0,268 1,2 0,31 0,10 0,28 0,5 1,6
appears when laid in water with moderate currents and limited depth. The design with water swellable yarn and aluminum foil bonded to the 3x95/25 0,193 0,8 0,30 0,09 0,32 0,6 1,8
sheath makes the cable both radial and longitudinal water sealed, which enhances the expected life length of the cable. Ripcords for easier and
safer stripping of the outer sheath. 3x120/25 0,153 0,8 0,29 0,09 0,34 0,6 1,9
3x150/25 0,124 0,8 0,28 0,09 0,38 0,7 2,1
3x185/35 0,0991 0,6 0,27 0,09 0,41 0,8 2,3
3x240/35 0,0754 0,6 0,26 0,08 0,46 0,9 2,6
Alternative Product Name Flame retardance Environmental
SE-N10XC7A5T5E-R Flame retardant - Not applicable Enviromantal Declaration - FXLJ-TT
Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
screen area core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp. during 1s at initial temp.
65ºC kA 90ºC kA
Standard 3x35/16 140 135 165 5,5 5,0 -
SS 424 14 16 Construction standard 12-36 kV 3x50/16 175 165 205 7,8 7,1 55
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
3x70/16 210 205 250 11,0 10,0 60
3x95/25 250 240 295 14,9 13,6 65
3x120/25 285 280 340 18,9 17,2 65
3x150/25 325 320 390 23,6 21,5 70
Construction
3x185/35 360 360 435 29,1 26,5 70
Cable Shape Triangular
Conductors Stranded, round and compacted copper acc. to IEC 60228 class 2, longitudinal water sealed 3x240/35 415 420 515 37,7 34,4 70
Inner semi-conducting layer Extruded The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Conductor Insulation XLPE, min. thickness = 2,96 mm
of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape and swellable yarn
Shield / Screen Annealed copper wires
Radial water blocking Aluminium foil bonded to the sheath
Ripcord Aramid
Outer Sheath PE, black
Example of marking on sheath FXLJ-TT 12kV 3x95/25 DRAKA "Date", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 75 kV

52 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 53
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 12 kV 1x50/16 500 K11 CA. 80150421
1x400/35 500 K18 CA. 80150429
FXLJ -TTCL TSLF 6/10(12) kV 1x500/35 500 K20 CA. 80150430

Conductors and Conductor Screen Inductance in Reactance in Capacitance Charging current/ Earth fault
screen area [mm2]  resistance Ω/km  resistance* trefoil/in flat* trefoil/in flat* µF/km  phase A/km current A/km
Ω/km  mH/km  Ω/km 
1x50/16 0,387 1,15 0,40/0,73 0,13/0,23 0,25 0,5 1,4
1x400/35 0,0470 0,524 0,29/0,54 0,09/0,17 0,58 1,1 3,3
1x500/35 0,0366 0,524 0,28/0,52 0,09/0,16 0,63 1,2 3,6
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.

Application Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before, *A  initial temp. 65ºC kA initial temp. 90ºC kA
during and after installation. Ripcords for easier and safer stripping of the outer sheath.
1x50/16 205 205 250 7,8 7,1
1x400/35 625 680 835 62,9 57,4
1x500/35 695 765 940 78,7 71,7
Alternative Product Name Flame retardance Environmental * Trefoil with screen grounded in both end.
SE-N10XC7A5T5E-FR Flame retardant - Not applicable Environmental declaration - FXLJ-TTCL The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
TSLF of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Standard
SS 424 14 16 Construction standard 12-36 kV
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard

Construction
Cable Shape Round
Conductors Stranded, round and compacted copper acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 2,96 mm
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Shield / Screen Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminum-PE laminate, bonded to sheath
Ripcord Aramid
Outer Sheath PE, natural, UV-protected
Example of marking on sheath FXLJ-TTCL TSLF 12kV 1x50 FR/16 DRAKA "Date and time", metre marked
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing)

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 75 kV

54 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 55
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 1x50/16 500 K12 7330384707893 20102178
1x70/16 500 K12 7330384714006 20113275
AXLJ -TTCL TSLF 12/20(24) kV 1x95/25 500 K12 7330384707299 20102179
1x120/25 500 K14 7330384714013 20113276
1x150/25 500 K14 7330384707879 20102180
1x185/35 500 K16 7330384714020 20113277
1x240/35 500 K16 7330384707701 20102181
1x300/35 500 K18 7330384714037 20113278
1x400/35 500 K18 7330384707022 20102182
1x500/35 500 K20 7330384714044 20113279
1x630/50 500 K20 7330384709392 20102183
1x800/50 500 K22 7330384714051 20113280
Application 1x1000/50 500 K24 7330384720656 20118907
Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water 1x1200/50 500 K26 7330384720038 20118927
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before,
during and after installation. Ripcords for easier and safer stripping of the outer sheath.
Conductors and screen Conductor Screen resistance* Inductance in trefoil/in Reactance Capacitance Charging current/ Earth fault
area [mm2]  resistance Ω/km  Ω/km  flat* mH/km  Ω/km  µF/km  phase A/km current A/km
1x50/16 0,641 1,15 0,43/0,73 0,23 0,17 0,6 1,9
Alternative Product Name Flame retardance Environmental 1x70/16 0,443 1,15 0,41/0,70 0,22 0,19 0,7 2,1
SE-N20XC7A5T5E-AR Flame retardant - Not applicable Enviromantal Declaration - AXLJ-TTCL 1x95/25 0,320 0,727 0,39/0,67 0,21 0,21 0,8 2,4
1x150/25 0,206 0,727 0,36/0,63 0,20 0,25 0,9 2,8
1x185/35 0,164 0,524 0,35/0,61 0,19 0,27 1,0 3,1
1x240/35 0,125 0,524 0,34/0,59 0,19 0,30 1,1 3,4
Standard 1x300/35 0,100 0,524 0,33/0,57 0,18 0,33 1,2 3,7
SS 424 14 16 Construction standard 12-36 kV 1x400/35 0,0778 0,524 0,30/0,55 0,17 0,37 1,4 4,2
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 1x500/35 0,0605 0,524 0,31/0,53 0,17 0,40 1,5 4,5
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard
1x630/50 0,0469 0,387 0,29/0,51 0,16 0,45 1,7 5,1
1x800/50 0,0367 0,387 0,29/0,50 0,16 0,45 1,7 5,1
1x1000/50 0,0291 0,387 0,27/0,48 0,15 0,47 1,8 5,3
1x1200/50 0,0247 0,387 0,29/0,48 0,15 0,51 1,9 5,8
Construction
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
Cable Shape Round
Conductors Stranded, round, compressed aluminium acc. to IEC 60228 class 2, longitudinally watertight
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 4,85 mm Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
Outer semi-conducting layer Bonded area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
Longitudinal water tightness Semi conducting water blocking tape *A  initial temp. 65ºC kA initial temp. 90ºC kA
Shield / Screen Annealed copper wires in contact with aluminum laminate
Radial water blocking Aluminium laminate, bonded to sheath 1x50/16 155 160 195 5,2 4,7
Ripcord Aramid 1x70/16 200 190 235 7,2 6,6
Outer Sheath PE, natural UV protected 1x95/25 235 230 280 9,9 8,9
Example of marking on sheath AXLJ-TTCL TSLF 24kV 1x150 AFR/25 DRAKA "Date and time", metre marked
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing) 1x120/25 265 265 325 12,4 11,3
1x150/25 300 300 370 15,6 14,2
Temperature 1x185/35 330 345 425 19,2 17,5
Maximum operating Temperature 90 ºC 1x240/35 385 400 490 25,0 22,7
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken. 1x300/35 435 460 565 31,2 28,3
1x400/35 510 555 680 41,6 37,8
Features 1x500/35 570 635 775 52,0 47,2
Bending radius In fixed installation: 10 x D 1x630/50 635 720 880 65,6 59,5
When pulling-in: 15 x D
When plowing down: 8 x D 1x800/50 695 822 1010 83,2 75,6
1x1000/50 760 920 1130 103,7 94,5
Electrical 1x1200/50 815 1000 1230 124,0 113,0
Impulse voltage [kV] 125 kV * Trefoil with screen grounded in both end.
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

56 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 57
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 3x1x50/16 500 K22 7330384708999 20102184
3x1x70/16 500 K24 7330384721936 20115022
AXLJ -TTCL TSLF Triplex 12/20(24) kV 3x1x95/25 500 K24 7330384709019 20102185
3x1x120/25 500 K24 7330384721943 20115023
3x1x150/25 500 K26 7330384709125 20102186
3x1x185/35 500 K26 7330384721950 20115024
3x1x240/35 500 K28 7330384709026 20102187
3x1x300/35 500 K28 7330384721967 20115025
3x1x400/35 500 K28 7330384713320 20111044

Conductors and screen Conductor Screen resistance* Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  resistance Ω/km  Ω/km  mH/km  Ω/km  µF/km  phase A/km current A/km
Application 3x1x50/16 0,641 1,15 0,44 0,14 0,17 0,6 1,9
Single-core, distribution cable for outdoor use in triplex formation. Installation in pipes and ground/water. Both radial and longitudinal water 3x1x70/16 0,443 1,15 0,41 0,13 0,19 0,7 2,1
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before, 3x1x95/25 0,320 0,727 0,39 0,12 0,21 0,8 2,4
during and after installation. Ripcords for easier and safer stripping of the outer sheath.
3x1x120/25 0,253 0,727 0,38 0,12 0,23 0,9 2,6
3x1x150/25 0,206 0,727 0,36 0,11 0,25 0,9 2,8
3x1x185/35 0,164 0,524 0,35 0,11 0,27 1,0 3,1
Alternative Product Name Flame retardance Environmental 3x1x240/35 0,125 0,524 0,34 0,11 0,30 1,1 3,4
SE-N20XC7A5T5E-AR Flame retardant - Not applicable Enviromantal Declaration - AXLJ-TTCL 3x1x300/35 0,100 0,524 0,33 0,10 0,33 1,2 3,7
3x1x400/35 0,0778 0,524 0,31 0,10 0,37 1,4 4,2
*Note screen resistance is the sum of copper wires and aluminum tape.

Standard Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard *A  initial temp. 65ºC kA initial temp. 90ºC kA
3x1x50/16 155 160 195 5,2 4,7
3x1x70/16 200 190 235 7,2 6,6
3x1x95/25 235 230 280 9,9 8,9
Construction 3x1x120/25 265 265 325 12,4 11,3
Cable Shape Round
3x1x150/25 300 300 370 15,6 14,2
Conductors Stranded, round and compacted aluminum acc. to IEC 60228 class 2, longitudinally watertight
Inner semi-conducting layer Extruded 3x1x185/35 330 345 425 19,2 17,5
Conductor Insulation XLPE, min. thickness = 4,85 mm 3x1x240/35 385 400 490 25,0 22,7
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape 3x1x300/35 435 460 565 31,2 28,3
Shield / Screen Annealed copper wires in contact with aluminum tape 3x1x400/35 510 555 680 41,6 37,8
Radial water blocking Aluminum-PE laminate, bonded to sheath * Trefoil with screen grounded in both end.
Ripcord Aramid
Outer Sheath PE, natural UV-protected The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Example of marking on sheath AXLJ-TTCL TSLF 24kV 1x50 AFR/16 DRAKA "Date and time", 1-core is metre marked of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing)

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 125 kV

58 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 59
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 3x50+35 20kV 500 K24 6410006242504 20022490
3x95+35 20kV 500 K26 6410006242528 20022491
AHXAMK-W 12/20 (24) kV 3x120+35 20kV 500 K26 6410006242535 20022492
3x150+35 20kV 500 K26 6410006242542 20022493
3x185+35 20kV 500 K26 6410006242559 20022495
3x240+35 20kV 500 K28 6410006242566 20022499
3x240+70 20kV 500 K28 6410006242566 20022498
3x300+35 20kV 500 K28 6410006242597 20022502
3x300+70 20kV 500 K28 6410006242573 20022501

Conductor Centre conductor Inductance/


Cable weight resistance resistance phase
Application Conductors and screen area [mm2] Cable diameter [mm] [kg/km] [Ω/km] [Ω/km] [mH/km] Capacitance [μF/km]
Medium voltage power cable with stranded and compacted aluminium longitudinal and radial water sealed conductor. For fixed outdoor AHXAMK-W 3x50+35   64 2350 0.641 0.524 0.46 0.17
installation, can be ploughed down. AHXAMK-W 3x95+35   71 3100 0.32 0.524 0.4 0.21
AHXAMK-W 3x120+35   74 3450 0.253 0.524 0.39 0.23
AHXAMK-W 3x150+35   76 3800 0.206 0.524 0.37 0.24
AHXAMK-W 3x185+35   80 4300 0.164 0.524 0.36 0.26
Alternative Product Name Flame retardance
AHXAMK-W 3x240+70   89 5500 0.125 0.268 0.35 0.3
WISKI® Flame retardant - Not applicable
AHXAMK-W 3x300+70   94 6250 0.1 0.268 0.34 0.32

Max. short circuit


Current rating Current rating current on the
Standard
at core temp. Current rating at core temp. conductor during 1s at
HD 620-10F Harmonized construction standard
IEC 60502-2 Construction standard Charging current/ Earth fault 65ºC in ground at core temp. 90ºC in air* initial temp.*** 90ºC
Conductors and screen area [mm2] phase [A/km] current [A/km] [A] 65ºC in air* [A] [A] kA
AHXAMK-W 3x50+35   0.6 1.8 155 160 195 4.7
AHXAMK-W 3x95+35   0.8 2.3 235 230 280 8.9
Construction AHXAMK-W 3x120+35   0.8 2.5 265 265 325 11.3
Cable Shape Round AHXAMK-W 3x150+35   0.9 2.6 300 300 370 14.1
UNSPSC classification 26121629 AHXAMK-W 3x185+35   1 2.9 330 345 425 17.4
Conductors Stranded, round, compacted aluminium, longitudinally watertight
Center conductor Round, stranded and compacted copper conductor AHXAMK-W 3x240+70   1.1 3.2 385 400 510 22.6
Inner semi-conducting layer Semi-conducting PEX AHXAMK-W 3x300+70   1.2 3.5 435 460 565 28.3
Conductor Insulation PEX * Trefoil with screen grounded in both end.
Individual screen for parts Semi-conducting PEX
Core assembly Three cores are stranded around the centre conductor The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –
Inner covering Conductive tape air temperature 25ºC –thermal resistivity of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Shield / Screen Aluminium foil bonded tightly to sheath
Overall sheath Black PE
Example of marking on sheath AHXAMK-W 12/20 kV 3x150+35 DRAKA "Date and time", 1 core is metre marked
Semi-conducting layer in outer sheath  Semi-conducting tape

Temperature
Maximum operating Temperature 90°C
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Min. Bending radius at final installation 8 xD
Min. Bending radius at during installation 15 xD
Max Pulling force - pulling grip [N/mm2] 15 N/mm² xA
Max Pulling force - pulling eye [N/mm2] 50 N/mm² xA

Electrical
Max. short circuit temperature [°C] 250°C

60 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product development
development and/or
and/or changes in product changes
standard. in2017-12-19
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 61
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 3x50/16 500 K20 7330384701136 20078233
3x95/25 500 K22 7330384701150 20102136
AXLJ -RMF 12/20(24) kV 3x150/25 500 K24 7330384701075 20078234
3x240/25 500 K26 7330384701082 20102137
3x240/35 500 K26 7330384714167 20091033
3x300/35 500 K26 7330384715072 20118046

Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
3x50/16 0,641 1,2 0,37 0,12 0,17 0,6 1,9
3x95/25 0,320 0,8 0,34 0,11 0,21 0,8 2,4
3x150/25 0,206 0,8 0,31 0,10 0,25 0,9 2,8
Application 3x240/35 0,125 0,6 0,29 0,09 0,30 1,1 3,4
AXLJ-RMF is a 3-core cable designed for replacement of bare overhead lines. Primary developed to be ploughed down but thanks to the robust 3x300/35 0,100 0,6 0,28 0,09 0,33 1,2 3,7
design the cable can stand the stresses that appears when laid in water with moderate currents and limited depth. Ripcords for easier and safer
stripping of the outer sheath.
Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
screen area core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp. during 1s at initial temp.
Alternative Product Name Flame retardance Environmental 65ºC kA 90ºC kA
SE-N20XC7E-AR Flame retardant - Not applicable Enviromantal Declaration - AXLJ-F, -RMF 3x50/16 145 130 160 5,2 4,7 55
LT 3x95/25 205 190 230 9,9 8,9 65
3x150/25 260 250 305 15,6 14,2 70
3x240/35 340 330 400 25,0 22,7 70
3x300/35 380 375 460 31,2 28,3 70
Standard The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
SS 424 14 16 Construction standard 12-36 kV of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard

Construction
Cable Shape Triangular
Conductors Stranded, round, compacted aluminum acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 4,85 mm
Outer semi-conducting layer Bonded
Inner covering Conductive tape
Shield / Screen Annealed copper wires
Ripcord Aramid
Outer Sheath Composite PE, black
Example of marking on sheath AXLJ-RMF 24kV 3x150/25 LT DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D

Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 125 kV

62 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 63
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 3x50/16 500 K22 7330384720236 20203889
3x70/16 500 K22 7330384720243 20203890
AXQJ-RMF Pure 12/20(24) kV 3x95/25 500 K24 7330384720250 20203891
3x120/25 500 K24 7330384720267 20203892
3x150/25 500 K24 7330384720274 20203893
3x185/35 500 K24 7330384720281 20203894
3x240/35 500 K26 7330384720298 20203895
3x300/35 500 K26 7330384720311 20203896

Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
3x50/16 0,641 1,2 0,37 0,12 0,17 0,6 1,9
Application 3x70/16 0,443 1,2  0,35  0,11  0,19  0,7  2,1 
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and 3x95/25 0,320 0,8 0,34 0,11 0,21 0,8 2,4
not harmful to electronic equipment. The cable is primarily designed for indoor installation, tunnels, etc. The cable can be installed outdoors 3x120/25 0,253  0,8  0,32  0,10  0,23  0,9  2,6 
and in ground but ploughing is not recommended. Ripcords for easier and safer stripping of the outer sheath.
3x150/25 0,206 0,8 0,31 0,10 0,25 0,9 2,8
3x185/35 0,164 0,6  0,30  0,09  0,27  1,0  3,1 
3x240/35 0,125 0,6 0,29 0,09 0,30 1,1 3,4
Alternative Product Name Environmental 3x300/35 0,100 0,6 0,28  0,09  0,33  1,2 3,7
SE-N20XC7Z1-AR Environmental Declaration - AXQJ-RMF Pure
Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
screen area core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp. during 1s at initial temp.
Standard 65ºC kA 90ºC kA
SS 424 14 16 Construction standard 12-36 kV 3x50/16 145 130 160 5,2 4,7 55
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 3x70/16 175 155 190 7,2 6,6 60
IEC 60502-2 Construction standard
CENELEC HD 604 Halogen free material 3x95/25 205 190 230 9,9 8,9 65
SS-EN 60754-1, -2 Corrosive gases 3x120/25 230 220 265 12,4 11,3 65
SS-EN 61034-1, -2 Smoke density 3x150/25 260 250 305 15,6 14,2 70
EN 50575:2014 Power, control and communication cables - Cables for general applications in construction
works subject to reaction to fire requirements 3x185/35 290 280 340 19,2 17,5 70
3x240/35 340 330 400 25,0 22,7 70
3x300/35 380 375 460 31,2 29,8 70
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Construction of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Cable Shape Triangular
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 4,85 mm
Outer semi-conducting layer Bonded
Inner covering Conductive tape
Shield / Screen Annealed copper wires
Ripcord Aramid
Outer Sheath Halogen free compound, black
Example of marking on sheath AXQJ-RMF Pure 24kV 3x50/16 LT B2-s1d0a2 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
CPR Performance class B2ca-s1d0a2
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D

Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 125 kV

64 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 65
Electrical
Max. short circuit temperature [°C] 250°C
Impulse voltage [kV] 125 kV

Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 3x50/16 500 K22 7330384721745 20206420

AXCLJ -TT 12/20(24) kV


3x70/16 500 K22 20206421
3x95/25 500 K24 7330384721738 20206422
3x120/25 500 K24 20206423
3x150/25 500 K24 7330384721721 20206424
3x185/35 500 K26 20206425
3x240/35 500 K26 7330384721714 20206426
3x300/35 500 K26 20206427

Conductors and Conductor Screen Inductance Reactance Capacitance Zero sequence Charging Earth fault
screen area resistance Ω/km  resistance*  mH/km  Ω/km  µF/km  impedance Z0 current/ current
[mm2]  Ω/km  Ω/km phase A/km A/km
Application 3x50/16 0,641 1,2 0,37 0,12 0,17 1,30+j0,83 0,6 1,9
AXCLJ-TT is just as AXALJ-TT totally water sealed. Radial water sealed by an aluminum laminate bonded to outer sheath and longitudinally water 3x70/16 0,443 1,2 0,35 0,11 0,19 1,05+j0,80 0,7 2,1
sealed with swellable tapes. The screen is made up of circular copper wires like AXALJ-TT, water blocking tapes (replacing water blocking yarns) 3x95/25 0,320 0,8 0,34 0,11 0,21 0,91+j0,69 0,8 2,4
and the cable has been complemented with two strong ripcords for easier and safer opening of the outer sheath. The cable is primarily designed
for ploughing down in ground, but thanks to its robust design can handle the stresses resulting from installation in lakes with limited currents 3x120/25 0,253 0,8 0,32 0,10 0,23 0,82+j0,67 0,9 2,6
and of limited depth. 3x150/25 0,206 0,8 0,31 0,10 0,25 0,75+j0,66  0,9 2,8
3x185/35 0,164 0,6 0,30 0,10 0,27 0,69+j0,56 1,0 3,1
3x240/35 0,125 0,6 0,29 0,09 0,30 0,64+j0,54 1,1 3,4
3x300/35 0,100 0,6 0,28 0,09 0,33 0,58+j0,45 1,2 3,7
Alternative Product Name Feature
*Note! Screen resistance is the sum of copper wires and aluminum tape. The screen cross-section is made up of 60% copper.
SE-N20XC7A5T5E-AR The corresponding options with aluminum
screen. - AXALJ-TT
Flame retardance Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max. short circuit Max impulse current
Flame retardant - Not applicable Environmental screen area core temp. 65ºC core temp. 65ºC core temp. 90ºC current on the current on the current on the screen kA
Environmental declaration - AXCLJ-TT [mm2]   in ground A  in air A  in air A   conductor during 1s conductor during 1s during 1s kA 
at initial temp. 65ºC at initial temp. 90ºC
kA kA
3x50/16 145 130 160 5,2 4,7 3,2 55
Standard 3x70/16 175 155 190 7,2 6,6 3,2 60
SS 424 14 16 Construction standard 12-36 kV 3x95/25 205 190 230 9,9 8,9 5 65
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 3x120/25 230 220 265 12,4 11,3 5 65
3x150/25 260 250 305 15,6 14,2 5 70
3x185/35 290 280 340 19,2 17,5 7 70
3x240/35 340 330 400 25,0 22,7 7 70
Construction 3x300/35 380 375 460 31,2 28,3 7 70
Cable Shape Triangular The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Conductors Stranded, round, compacted aluminum acc. to IEC 60228 class 2, longitudinal water sealed
Inner semi-conducting layer Extruded of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Conductor Insulation XLPE, min. thickness = 4,85 mm
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Filler PE-profiles
Inner covering Conductive tape
Shield / Screen Round copper wires in contact with aluminum laminate
Radial water blocking Aluminum-PE laminate, bonded to sheath
Ripcord Aramid
Outer Sheath Composite PE, Black
Example of marking on sheath AXCLJ-TT 24kV 3x50/16 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D
Max Pulling force - pulling grip [N/mm2] Max. pulling forse = 5 x D ^ 2 (N)
D = outer diameter of cable (mm)
Max Pulling force - pulling eye [N/mm2] Max. pulling forse = 30 x S (N)
S = cross-sectional area of conductor (mm^2)
We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-16

66 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 67
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 1x50/16 500 K12 7330384720663 20217589
1x95/25 500 K12 7330384720687 20217591
AXQJ-TT Pure TSLI 12/20(24) kV 1x150/25 500 K14 7330384720700 20217593
1x240/35 500 K16 7330384720724 20217595
1x400/35 500 K18 7330384720748 20217597
1x500/35 500 K20 7330384720755 20217598
1x630/50 500 K20 7330384720762 20217599

Conductors and screen Conductor Screen resistance* Inductance in trefoil/in Reactance Capacitance Charging current/ Earth fault
area [mm2]  resistance Ω/km  Ω/km  flat* mH/km  Ω/km  µF/km  phase A/km current A/km
1x50/16 0,641 1,15 0,43/0,73 0,14/0,23 0,17 0,6 1,9
1x95/25 0,320 0,727 0,39/0,67 0,12/0,21 0,21 0,8 2,4
Application 1x150/25 0,206 0,727 0,36/0,63 0,11/0,20 0,25 0,9 2,8
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and 1x240/35 0,125 0,524 0,34/0,59 0,11/0,19 0,30 1,2 3,4
not harmful to electronic equipment. Radial and longitudinal water sealed distribution cable for use indoors and outdoors for 3-phase 1x400/35 0,0778 0,524 0,31/0,55 0,10/0,17 0,37 1,4 4,2
formation. Installation in pipes and ground. Ploughing down is not recommended. Ripcords for easier and safer stripping of the outer sheath.
1x500/35 0,0605 0,524 0,30/0,53 0,09/0,17 0,40 1,5 4,5
1x630/50 0,0469 0,387 0,29/0,51 0,09/0,16 0,45 1,7 5,1
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
Alternative Product Name Environmental
SE-N20XC7A5Z1-AR Enviromantal Declaration - AXQJ-TT Pure TSLI Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
*A  initial temp. 65ºC kA initial temp. 90ºC kA
1x50/16 155 160 195 5,2 4,7
Standard 1x95/25 235 230 280 9,9 8,9
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 1x150/25 300 300 370 15,6 14,2
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard 1x240/35 385 400 490 25,0 22,7
CENELEC HD 604 Halogen free material
SS-EN 60754-1, -2 Corrosive gases 1x400/35 510 555 680 41,6 37,8
SS-EN 61034-1, -2 Smoke density 1x500/35 570 635 775 52,0 47,2
EN 50575:2014 Power, control and communication cables - Cables for general applications in construction
1x630/50 635 720 880 65,6 59,5
works subject to reaction to fire requirements
* Trefoil with screen grounded in both end.
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Construction
Cable Shape Round
Conductors Stranded, round, compressed aluminium acc. to IEC 60228 class 2, longitudinally watertight
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 4,85 mm
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Shield / Screen Annealed copper wires in contact with aluminum laminate
Radial water blocking Aluminium laminate, bonded to sheath
Ripcord Aramid
Outer Sheath Halogen free compound, black
Example of marking on sheath AXQJ-TT Pure TSLI 24kV 1x120 AFR/25 D-s2d2a2 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
CPR Performance class Dca-s2d2a2
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 125 kV

68 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 69
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 3x25/25 AL 500 K20 20158170
3x50/25 AL 500 K22 7330384717083 20151647
AXALJ -TT 12/20(24) kV 3x70/25 AL 500 K22 7330384717090 20151648
3x95/35 AL 500 K24 7330384717106 20151649
3x120/35 AL 500 K24 7330384717151 20152033
3x150/35 AL 500 K24 7330384717113 20151650
3x185/50 AL 500 K26 7330384717168 20152034
3x240/50 AL 500 K26 7330384717120 20151651
3x300/50 AL 500 K26 7330384717175 20152035

Conductors and screen Conductor resistance Screen resistance Inductance Reactance Capacitance Charging current/ Earth fault
area [mm2]  Ω/km  Ω/km   mH/km  Ω/km  µF/km  phase A/km current A/km
Application 3x25/25 AL 1,20 1,2 0,41 0,13 0,14 0,5 1,6
AXALJ-TT is just like its predecessor AXLJ-TT, totally water sealed. Radially water sealed by an aluminium laminate bonded to the outer sheath 3x50/25 AL 0,641 1,2 0,37 0,12 0,17 0,6 1,9
longitudinally water sealed with swellable tapes. The screen is made up of circular aluminium wires, water blocking tapes (replacing the water 3x70/25 AL 0,443  1,2 0,35  0,11  0,19  0,7  2,1 
swellable yarns) and the cable has been complemented with two strong ripcords for easier and safer opening of the outer sheath. The cable is
primarily designed for ploughing down in ground, but thanks to its robust design can handle the stresses resulting from installation in lakes 3x95/35 AL 0,320 0,8 0,34 0,11 0,21 0,8 2,4
with limited currents and of limited depth. 3x120/35 AL 0,253  0,8 0,32  0,10  0,23  0,9  2,6 
3x150/35 AL 0,206 0,8 0,31 0,10 0,25 0,9 2,8
3x185/50 AL 0,164  0,6 0,30  0,09  0,27  1,0  3,1
3x240/50 AL 0,125 0,6 0,29 0,09 0,30 1,1 3,4
Alternative Product Name Flame retardance Environmental
3x300/50 AL 0,100 0,6 0,28 0,09 0,33 1,2 3,7
SE-N20XA5E-AR Flame retardant - Not applicable Enviromantal Declaration - AXALJ-TT

Conductors and Current rating at Current rating at Current rating at Max. short circuit Max. short circuit Max impulse current kA
screen area core temp. 65ºC in core temp. 65ºC in core temp. 90ºC in current on the conductor current on the conductor
[mm2]   ground A  air A  air A   during 1s at initial temp. during 1s at initial temp.
Standard
65ºC kA 90ºC kA
SS 424 14 16 Construction standard 12-36 kV
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 3x25/25 AL 100 90 110 2,6 2,3 -
3x50/25 AL 145 130 160 5,2 4,7 55
3x70/25 AL 175  155  190  7,2  6,6  60 
3x95/35 AL 205 190 230 9,9 8,9 65
Construction 3x120/35 AL 230  220  265  12,4  11,3  65
Cable Shape Triangular 3x150/35 AL 260 250 305 15,6 14,2 70
Conductors Stranded, round, compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed 3x185/50 AL 290  280  340  19,2  17,5  70
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 4,85 mm 3x240/50 AL 340 330 400 25,0 22,7 70
Outer semi-conducting layer Bonded 3x300/50 AL 380 375 460 31,2 28,3 70
Longitudinal water tightness Semi conducting water blocking tape The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Filler PE-profiles
Shield / Screen Round aluminium wires in contact with aluminium laminate of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Radial water blocking Aluminium laminate, bonded to sheath
Ripcord Aramid
Outer Sheath Composite PE, Black
Example of marking on sheath AXALJ-TT 24kV 3x50/25 AL DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 8 x D
When pulling-in: 12 x D
When plowing down: 8 x D

Electrical
Max. short circuit temperature [°C] 250 ºC
Impulse voltage [kV] 125 kV

70 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 71
Standard delivery length Delivery Package SAP Number
[m]
Power cables 24 kV HXCMK 1x35/16 1000 K16 6410006032099 20022529

HXCMK 20 kV Resistance Resistance of Resistance Resistance of


of phase, phase, core of phase, phase, core Inductance Inductance
core temp. temp. 90ºC, core temp. temp. 90ºC, per phase, per phase,
Cable Cable Conductor 65ºC, flat flat 65ºC, trefoil trefoil flat trefoil
Conductors and diameter weight resistance formation formation formation formation formation formation Capacitance
screen area [mm2] [mm] [kg/km] [Ω/km] [Ω/km] [Ω/km] [Ω/km] [Ω/km] [mH/km] [mH/km] [μF/km]
HXCMK 1x35/16 26 920 0.524 0.64 0.69 0.17 0.68 0.64 0.45 0.16

Current Max. short


rating in air Current Current rating circuit current
Application at core rating in air Current rating Current rating Current rating in ground at on the
Medium voltage power cable with stranded and compacted copper conductor. For fixed installation for the trenches and ladders indoors and Charging temp. 65ºC, at core temp. in air at core in air at core in ground at core temp. conductor
outdoors. current/ Earth fault flat 65ºC, trefoil temp. 90ºC, temp. 90ºC, core temp. 65ºC, trefoil during 1s at
Conductors and screen current formation, formation, flat formation, trefoil 65ºC, flat formation, initial temp.***
area [mm2] [A/km] [A/km] [A] [A] [A] formation, [A] formation, [A] [A] 90ºC kA
HXCMK 1x35/16 0.6 1.7 175 160 215 195 185 175 5
Flame retardance Approval The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –
EN 60332-1 CE air temperature 25ºC –thermal resistivity of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
IEC 60332-1 - Fire propagation class

Standard
IEC 60502-2 Construction standard

Construction
Cable Shape Round
Conductors Round, compacted copper conductor
Inner semi-conducting layer Semi-conducting PEX
Conductor Insulation PEX
Individual screen for parts Semi-conducting PEX
Inner covering Conductive tape
Copper wire layer helix and copper contact tape counter helix
Outer Sheath Black PVC
Example of marking on sheath Prysmian, product name, date of manufacture, outer sheath material designation, meter
marking
Semi-conducting tape

Temperature
Maximum operating Temperature 90°C
Temparatures at installation [°C] Lowest cable temperature during installation is -5°C.

Features
UV resistance Good
Bending radius 15 xD
Min. Bending radius at final installation 10 xD
Min. Bending radius at during installation 15 xD
Max Pulling force - pulling grip [N/mm2] 15 N/mm² xA
Max Pulling force - pulling eye [N/mm2] 50 N/mm² xA
REACH/SVHC declaration The cable does not contain any substances on the REACH/SVHC -list.

Electrical
Max. short circuit temperature [°C] 250°C

72 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-10
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 73
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power cables 24 kV 1x50/16 1000 K20 7330384714327 20117071
1x70/16 1000 K20 7330384714334 20117078
FXLJ -TT TSLE 12/20(24)kV 1x95/25 1000 K20 7330384714341 20117079
1x120/25 1000 K22 7330384714358 20117080
1x150/25 1000 K24 7330384714365 20117081
1x185/35 1000 K24 7330384714372 20117125
1x240/35 1000 K18 7330384714389 20117126
1x300/35 1000 K24 7330384714396 20117135
1x400/35 500 K22 7330384714402 20117136
1x500/35 1000 K18 7330384714419 20117137
1x630/50 1000 K18 7330384714426 20117138

Application Conductors and Conductor Screen Inductance in Reactance in Capacitance Charging current/ Earth fault
Single-core distribution cable suitable for laying outdoors in 3-phase formation. Installation in pipes and in ground/water. Both radial and screen area [mm2]  resistance Ω/km  resistance* trefoil/in flat* trefoil/in flat* µF/km  phase A/km current A/km
longitudinal water sealed. Can be ploughed down. Ω/km  mH/km   Ω/km 
1x50/16  0,387  1,15  0,43/0,73  0,14/0,23  0,17  0,6  1,9 
1x70/16  0,268  1,15  0,41/0,70  0,13/0,22  0,19  0,7  2,1 
1x95/25  0,193  0,727  0,39/0,67  0,11/0,21  0,21  0,8  2,4 
Alternative Product Name Flame retardance Environmental
1x120/25  0,153  0,727  0,38/0,65  0,12/0,21  0,23  0,9  2,6 
SE-20XC7A5T5E-R Flame retardant - Not applicable Enviromantal Declaration - FXLJ-TT
1x150/25  0,124  0,727  0,36/0,63  0,11/0,20  0,25  0,9  2,8 
1x185/35  0,0991  0,524  0,35/0,61  0,11/0,19  0,27  1,0  3,1 
1x240/35  0,0754  0,524 0,34/0,59  0,11/0,19  0,30  1,1  3,4 
1x300/35  0,0601  0,524 0,32/0,57  0,10/0,18  0,33  1,2  3,7 
Standard
1x400/35  0,0470  0,524  0,31/0,55  0,10/0,17  0,37  1,4  4,2 
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard 1x500/35  0,0366  0,524  0,30/0,53  0,09/0,17  0,40  1,5  4,5 
1x630/50 0,0283 0,387 0,29/0,51  0,09/0,16  0,45  1,7  5,4 
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.

Construction Conductors and Current rating at core Current rating at core Current rating at core Max. short circuit current Max. short circuit current on the
Cable Shape Round screen area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   on the conductor during 1s conductor during 1s at initial temp. 90ºC
Conductors Stranded, round and compacted copper acc. to IEC 60228 class 2, longitudinally water sealed *A  at initial temp. 65ºC kA kA
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 4,85 mm 1x50/16  205 205  250  7,8  7,1 
Outer semi-conducting layer Bonded 1x70/16  255  240  295  11,0  10,0 
Longitudinal water tightness Semi conducting water blocking tape
Shield / Screen Annealed copper wires in contact with aluminum tape 1x95/25  295  300  355  14,9  13,6 
Radial water blocking Aluminium laminate, bonded to sheath 1x120/25  335  335  410  18,9  17,2 
Outer Sheath PE, black 1x150/25  380  380  465  23,6  21,5 
Example of marking on sheath FXLJ-TT TSLE 24kV 1x50 FR/16 DRAKA "Date", metre marked
1x185/35  425  435  535  29,1  26,5 
Temperature 1x240/35  485  505  620  37,7  34,4 
Maximum operating Temperature 90 ºC 1x300/35  545  575  705  47,2  43,0 
Temparatures at installation [°C] Lowest cable temperature during installation, -20 ºC below 0 ºC special precaution shall be 1x400/35  625  680 835  62,9  57,4 
taken.
1x500/35  695  765  940  78,7  71,7 
Features 1x630/35  755  845  1035 99,1  90,4 
Bending radius In fixed installation: 10 x D * Trefoil with screen grounded in both end.
When pulling-in: 15 x D The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
When plowing down: 8 x D
of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Electrical
Impulse voltage [kV] 125 kV

74 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 75
Conductors and screen area Standard delivery length Delivery Package SAP Number
[mm2] [m]
Power Cables 36 kV 1x630/50 500 K22 CA.80140353

AXLJ -TT TSLE 18/30(36) kV Conductors and Conductor Screen Inductance in Reactancein trefoil/in Capacitance Charging current/ Earth fault
resistance Ω resistance* trefoil/in flat* Ω phase A/km current A/km

1x630/50 0,0469 0,387 0,31/0,52 0,10/0,16 0,33 1,9 5,9
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.

Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
temp. 65ºC in ground the conductor during 1s at the conductor during 1s at
initial temp. 65ºC kA initial temp. 90ºC kA
1x630/50 635 720 880 65,5 59,5
Application * Trefoil with screen grounded in both end.
Single-core distribution cable suitable for laying outdoors in 3-phase formation. Installation in pipes and in ground/water. Both radial and The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
longitudinal water sealed. Can be ploughed down.
of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Alternative Product Name Flame retardance


SE-N30XC7A5T5E-AR Flame retardant - Not applicable

Standard
SS 424 14 16 Construction standard 12-36 kV
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard

Construction
Cable Shape Round
Conductors Stranded, round and compacted aluminum acc. to IEC 60228 class 2, longitudinally water sealed
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, min. thickness = 7,1 mm
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminium-PE laminate, bonded to sheath
Outer Sheath PE, black
Example of marking on sheath AXLJ-TT TSLE 36kV 1x630 AFR/50 DRAKA "Date, metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 170 kV

76 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 77
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 36 kV 1x50/25 500 K14 7330384719087 20114470
1x70/25 500 K14 7330384719094 20114471
AXLJ -TTCL TSLF 18/30(36) kV 1x95/25 500 K16 7330384713665 20102188
1x120/35 500 K16 7330384719100 20114472
1x150/35 500 K18 7330384719117 20114473
1x185/35 500 K18 7330384713658 20102189
1x240/35 500 K18 7330384719124 20114474
1x300/35 500 K20 7330384713689 20102190
1x400/35 500 K20 7330384713702 20102191
1x500/35 500 K22 7330384713672 20102192
1x630/50 500 K22 7330384716772 20114469
1x800/50 500 K24 7330384718158 20114475
Application 1x1000/50 500 K26 CA. 80160229
Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before,
during and after installation. Ripcords for easier and safer stripping of the outer sheath. Conductors and Conductor Screen Inductance in Reactance in Capacitance Charging current/ Earth fault
screen area [mm2]  resistance Ω/km  resistance* trefoil/in flat* trefoil/in flat* µF/km  phase A/km current A/km
Ω/km  mH/km   Ω/km 
1x50/25 0,641 0,727 0,47/0,75 0,15/0,24 0,13 0,7 2,2
Alternative Product Name Flame retardance Environmental 1x70/25 0,443 0,727 0,44/0,71 0,14/0,22 0,14 0,8 2,4
SE-N30XC7A5T5E-AR Flame retardant - Not applicable Environmental declaration - AXLJ-TTCL 1x95/25 0,320 0,727 0,42/0,68 0,13/0,21 0,16 0,9 2,7
TSLF 1x120/35 0,253 0,524 0,41/0,66 0,13/0,21 0,17 1,0 2,9
1x150/35 0,206 0,524 0,39/0,64 0,12/0,20 0,19 1,1 3,2
1x185/35 0,164 0,524 0,38/0,62 0,12/0,20 0,20 1,1 3,4
1x240/35 0,125 0,524 0,36/0,60 0,11/0,19 0,22 1,2 3,7
Standard 1x300/35 0,100 0,524 0,35/0,58 0,11/0,18 0,24 1,4 4,1
SS 424 14 16 Construction standard 12-36 kV 1x400/35 0,0778 0,524 0,34/0,56 0,11/0,18 0,27 1,5 4,6
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard 1x500/35 0,0605 0,524 0,32/0,54 0,10/0,17 0,29 1,6 4,9
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard
1x630/50 0,0469 0,387 0,31/0,52 0,10/0,16 0,33 1,9 5,9
1x800/50 0,0367 0,387 0,30/0,50 0,09/0,16 0,36 2,0 6,1
1x1000/50 0,0291  0,387  0,30/0,49  0,09/0,15  0,40  2,3  6,8
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
Construction
Cable Shape Round
Conductors Stranded, round and compacted aluminium acc. to IEC 60228 class 2, longitudinal water sealed Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
Inner semi-conducting layer Extruded
area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
Conductor Insulation XLPE, min. thickness = 7,1 mm
Outer semi-conducting layer Bonded *A  initial temp. 65ºC kA initial temp. 90ºC kA
Longitudinal water tightness Semi conducting water blocking tape 1x50/25 155 160 195 5,2 4,7
Shield / Screen Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminium-PE laminate, bonded to sheath 1x70/25 200 190 235 7,2 6,6
Ripcord Aramid 1x95/25 235 230 280 9,9 8,9
Outer Sheath PE, natural, UV-protected 1x120/35 265 265 325 12,4 11,3
Example of marking on sheath AXLJ-TTCL TSLF 36kV 1x95 AFR/25 DRAKA "Date and time", metre marked
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing) 1x150/35 300 300 370 15,6 14,2
1x185/35 330 345 425 19,2 17,5
Temperature 1x240/35 385 400 490 25,0 22,7
Maximum operating Temperature 90 ºC 1x300/35 435 460 565 31,2 28,3
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken. 1x400/35 510 555 680 41,6 37,8
1x500/35 570 635 775 52,0 47,2
Features 1x630/50 635 720 880 65,6 59,5
Bending radius In fixed installation: 10 x D 1x800/50 695 822 1010 83,2 75,6
When pulling out: 15 x D
When plowing down: 8 x D 1x1000/50 760  920  1130  103,7  94,5 
* Trefoil with screen grounded in both end.
Electrical The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Max. short circuit temperature [°C] 250ºC of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Impulse voltage [kV] 170 kV

78 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 79
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 36 kV 1x50/25 500 K14 CA.81138117
1x70/25 500 K14 CA.81138118
AXQJ-TT Pure TSLI 18/30(36) kV 1x95/25 500 K16 CA.81138119
1x120/35 500 K16 CA.81138120
1x150/35 500 K16 CA.81138121
1x185/35 500 K18 CA.81138122
1x240/35 500 K18 CA.81138123
1x300/35 500 K20 CA.81138124
1x400/35 500 K20 CA.81138125
1x500/35 500 K22 CA.81138126
1x630/50 500 K22 CA.81138127
1x800/50 500 K24 CA.81138128
Application
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and Conductors and Conductor Screen Inductance in Reactance  i in Capacitance Charging current/ Earth fault
not harmful to electronic equipment. Radial and longitudinal water sealed distribution cable for use indoors and outdoors for 3-phase
screen area [mm2]  resistance Ω/km  resistance* trefoil/in flat* trefoil/in flat* Ω/km  µF/km  phase A/km current A/km
formation. Installation in pipes and ground. Ploughing down is not recommended. Ripcords for easier and safer stripping of the outer sheath.
Ω/km  mH/km 
1x50/25 0,641 0,727 0,47/0,74 0,15/0,23 0,13 0,7 2,2
1x70/25 0,443 0,727 0,44/0,71 0,14/0,22 0,14 0,8 2,4
Alternative Product Name Environmental 1x95/25 0,320 0,727 0,42/0,68 0,13/0,21 0,16 0,9 2,7
SE-N30XC7A5Z1-AR Enviromantal Declaration - AXQJ-TT Pure TSLI 1x120/35 0,253 0,524 0,40/0,66 0,13/0,21 0,17 1,0 2,9
1x150/35 0,206 0,524 0,39/0,64 0,12/0,20 0,19 1,1 3,2
1x185/35 0,164 0,524 0,38/0,62 0,12/0,20 0,20 1,1 3,4
1x240/35 0,125 0,524 0,36/0,60 0,11/0,19 0,22 1,2 3,7
Standard 1x300/35 0,100 0,524 0,35/0,58 0,11/0,18 0,24 1,4 4,1
CENELEC HD 620 Part 10 Section M Harmonized Construction Standard 1x400/35 0,0778 0,524 0,33/0,56 0,10/0,18 0,27 1,5 4,6
CENELEC HD 620 Part 10 Section K Harmonized Construction Standard 1x500/35 0,0605 0,524 0,32/0,54 0,10/0,17 0,29 1,6 4,9
CENELEC HD 604 Halogen free material
SS-EN 60754-1, -2 Corrosive gases 1x630/50 0,0469 0,387 0,31/0,52 0,10/0,16 0,33 1,9 5,9
SS-EN 61034-1, -2 Smoke density 1x800/50 0,0367 0,387 0,30/0,50 0,09/0,16 0,36 2,0 6,1
EN 50575:2014 Power, control and communication cables - Cables for general applications in construction * Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
works subject to reaction to fire requirements

Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
*A  initial temp. 65ºC kA initial temp. 90ºC kA
Construction
Cable Shape Round 1x50/25 155 160 195 5,2 4,7
Conductors Stranded, round, compacted aluminium acc. to IEC 60228 class 2, longitudinally watertight 1x70/25 200 190 235 7,2 6,6
Inner semi-conducting layer Extruded 1x95/25 235 230 280 9,9 8,9
Conductor Insulation XLPE, min. thickness = 7,6 mm
Outer semi-conducting layer Bonded 1x120/35 265 265 325 12,4 11,3
Longitudinal water tightness Semi conducting water blocking tape 1x150/35 300 300 370 15,6 14,2
Shield / Screen Annealed copper wires in contact with aluminum laminate
Radial water blocking Aluminium laminate, bonded to sheath 1x185/35 330 345 425 19,2 17,5
Ripcord Aramid 1x240/35 385 400 490 25,0 22,7
Outer Sheath Halogen free compound, black 1x300/35 435 460 565 31,2 28,3
Example of marking on sheath AXQJ-TT Pure TSLI 36kV 1x120 AFR/25 D-s2d2a2 DRAKA "Date and time", metre marked
1x400/35 510 555 680 41,6 37,8
Temperature 1x500/35 570 635 775 52,0 47,2
Maximum operating Temperature 90 ºC 1x630/50 635 720 880 65,6 59,5
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be 1x800/50 695 822 1010 83,2 75,6
taken.
* Trefoil with screen grounded in both end.
Features The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
CPR Performance class Dca-s2d2a2 of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 170 kV

80 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 81
Standard delivery length Delivery Package SAP Number
[m]
Power Cables 42 kV AXLJ-TT TSLE1x120/16 AFR 1000 K22 CA.80140189
42kV
AXLJ -TT TSLE 20,8/36(42) kV
Conductors and screen Conductor Screen resistance Inductance in trefoil/in Reactance Capacitance Charging current/ Earth fault
resistance Ω Ω Ω phase A/km current A/km
1x120/16 0,253 1,15 0,41/0,66 0,21 0,17 1,1 3,3
* Cable distance, installation in flat formation = 70 mm.

Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
temp. 90ºC in ground the conductor during 5s at the conductor during 5s at
initial temp. 65ºC kA initial temp. 90ºC kA
1x120/16 310 265 325 5,5 5,0

Application * Trefoil with screen grounded in both end.


Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
blocked. Can be ploughed down. of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Alternative Product Name Flame retardance


SE-N36XC7A5T5E-AR Flame retardant - Not applicable

Construction
Cable Shape Round
Conductors Stranded, round, compacted aluminium acc. to IEC 60228 class 2, longitudinally watertight
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, nom. thickness = 8,0 mm
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Annealed copper wires
Radial water blocking Aluminum-PE laminate, bonded to sheath
Outer Sheath PE, black, resistant to weather an UV
Example of marking on sheath AXLJ-TT TSLE 42kV 1x120 AFR/16 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be
taken. Fixed installed -35ºC/ +35ºC

Features
The dielectric loss factor (tg δ) at 50 Hz, between 20 ° C to 90 ° C < 0,6x10^-3
50 Hz voltage value, which keeps the device for 1 min. period: 70 kV
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D
Max Pulling force - pulling eye [N/mm2] Max. pulling forse = 30 x S (N)
S = cross-sectional area of conductor (mm^2)

Electrical
Max. short circuit temperature [°C] (5s) 250 ºC
Impulse voltage [kV] 200 kV

82 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-10
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 83
Conductors and screen area Standard delivery length Delivery Package EAN/GTIN number  SAP Number
[mm2] [m]
Power Cables 52 kV 1x50/25 500 K16 CA.80140194
1x70/25 500 K16 CA.80140193
AXLJ -TTCL TSLF 26/45(52) kV 1x95/25 500 K16 CA.80140192
1x120/35 500 K16 CA.80140191
1x150/35 500 K18 CA.80140128
1x185/35 500 K18 CA.80140129
1x240/35 500 K20 7330384713580 20111047
1x300/35 500 K20 7330384718325 20165484
1x400/35 500 K22 7330384718042 20159537
1x500/50 500 K22 7330384719384 20183095
1x630/50 500 K24 7330384714075 20113584
1x800/50 500 K24 7330384719070 20173864
Application
Single-core, distribution cable for outdoor use in 3-phase formation. Installation in pipes and ground/water. Both radial and longitudinal water Conductors and screen Conductor Screen resistance* Inductance in trefoil/in Reactance Capacitance Charging current/ Earth fault
sealed. Can be ploughed down. The outer sheath has a conductive layer that greatly extends the possibilities to do a sheath testing before,
area [mm2]  resistance Ω/km  Ω/km  flat* mH/km  Ω/km  µF/km  phase A/km current A/km
during and after installation. Ripcords for easier and safer stripping of the outer sheath.
1x50/25 0,641 0,727 0,49/0,75 0,24 0,12 1,0 2,9
1x70/25 0,443 0,727 0,46/0,72 0,23 0,13 1,1 3,2
1x95/25 0,320 0,727 0,44/0,69 0,22 0,14 1,1 3,4
Alternative Product Name Flame retardance Environmental 1x120/35 0,253 0,524 0,42/0,67 0,21 0,16 1,3 3,9
SE-N45XC7A5T5E-AR Flame retardant - Not applicable Environmental declaration - AXLJ-TTCL 1x150/35 0,206 0,524 0,41/0,65 0,20 0,17 1,4 4,2
TSLF 1x185/35 0,164 0,524 0,39/0,63 0,20 0,18 1,5 4,4
1x240/35 0,125 0,524 0,38/0,61 0,19 0,19 1,6 4,7
1x300/35 0,100 0,524 0,36/0,59 0,19 0,21 1,7 5,1
1x400/35 0,0778 0,524 0,35/0,56 0,18 0,24 2,0 5,9
Standard 1x500/35 0,0605 0,524 0,34/0,55 0,17 0,26 2,1 6,4
IEC 60840 Construction standard 1x630/50 0,0469 0,387 0,33/0,53 0,17 0,28 2,3 6,9
1x800/50 0,0367 0,387 0,32/0,51 0,16 0,31 2,5 7,6
* Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.

Construction Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
Cable Shape Round area [mm2]   temp. 65ºC in ground temp. 65ºC in air *A  temp. 90ºC in air *A   the conductor during 1s at the conductor during 1s at
Conductors Stranded, round, compressed aluminium acc. to IEC 60228 class 2, longitudinally watertight
Inner semi-conducting layer Extruded *A  initial temp. 65ºC kA initial temp. 90ºC kA
Conductor Insulation XLPE, nom. thickness = 9,0 mm 1x50/25 155 160 195 5,2 4,7
Outer semi-conducting layer Bonded 1x70/25 200 190 235 7,2 6,6
Longitudinal water tightness Semi conducting water blocking tape
Shield / Screen Annealed copper wires in contact with aluminum tape 1x95/25 235 230 280 9,9 8,9
Radial water blocking Aluminium-PE laminate, bonded to sheath 1x120/35 265 265 325 12,4 11,3
Ripcord Aramid
Outer Sheath PE, natural UV protected 1x150/35 300 300 370 15,6 14,2
Example of marking on sheath AXLJ-TTCL TSLF 52kV 1x50 AFR/25 DRAKA "Date and time", metre marked 1x180/35 330 345 425 19,2 17,5
Semi-conducting layer in outer sheath  Yes (facilitates sheath testing) 1x240/35 385 400 490 25,0 22,7
1x300/35 435 460 565 31,2 28,3
Temperature
1x400/35 510 555 680 41,6 37,8
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation -20 ºC, below 0 ºC special precaution shall be 1x500/50 570 635 775 52,0 47,2
taken. 1x630/50 635 720 880 65,6 59,5
1x800/50 695 822 1010 83,2 75,6
Features
* Trefoil with screen grounded in both end.
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
When plowing down: 8 x D of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz

Electrical
Impulse voltage [kV] 250 kV

84 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 85
Conductors and screen area Standard delivery length Delivery Package SAP Number
[mm2] [m]
Power Cables 52 kV 1x150/35 500 K18 CA.80140261
1x240/35 500 K20 CA.80140263
AXQJ-TT Pure 26/45(52)kV 1x500/50 500 K22 CA.80140266
1x800/50 500 K24 CA.80160083

Conductors and screen Conductor Screen resistance* Inductance in trefoil/in Reactance Capacitance Charging current/ Earth fault
resistance Ω Ω Ω phase A/km current A/km
1x50/16 0,641 1,15 0,40/0,72 0,23 0,25 0,5 1,4
1x95/25 0,320 0,727 0,36/0,66 0,21 0,32 0,6 1,8
1x150/25 0,206 0,727 0,33/0,62 0,20 0,38 0,7 2,1
1x240/35 0,125 0,524 0,31/0,58 0,18 0,46 0,9 2,6
1x400/35 0,0778 0,524 0,29/0,54 0,17 0,57 1,1 3,3
Application 1x500/35 0,0605 0,524 0,28/0,52 0,16 0,58 1,1 3,3
Halogen-free, flame retardant and self-extinguishing in case of fire. Smoke in the event of fire is limited, transparent (to facilitate evacuation) and 1x630/35 0,0469 0,524 0,27/0,50 0,16 0,64 1,2 3,6
not harmful to electronic equipment. Radial and longitudinal water sealed distribution cable for use indoors and outdoors for 3-phase * Cable distance, installation in flat formation = 70 mm. Note screen resistance is the sum of copper wires and aluminum tape.
formation. Installation in pipes and ground. Ploughing down is not recommended. Ripcords for easier and safer stripping of the outer sheath.

Conductors and screen Current rating at core Current rating at core Current rating at core Max. short circuit current on Max. short circuit current on
temp. 65ºC in ground the conductor during 1s at the conductor during 1s at
Alternative Product Name Environmental initial temp. 65ºC kA initial temp. 90ºC kA
SE-N45XC7A5Z1-AR Enviromantal Declaration - AXQJ-TT TSLI 1x50/16 155 160 195 5,2 4,7
1x95/25 235 230 280 9,9 8,9
1x150/25 300 300 370 15,6 14,2
1x240/35 385 400 490 25,0 22,7
Standard 1x400/35 510 555 680 41,6 37,8
IEC 60840 Construction standard 1x500/35 570 635 775 52,0 47,2
1x630/35 635 720 880 65,6 59,5
* Trefoil with screen grounded in both end.
The ratings are based on the following conditions –maximum conductor temperature 90ºC –ground temperature 15ºC –air temperature 25ºC –thermal resistivity
Construction of soil 1,0 ºKm/W –depth of burial 0,65 m –frequency 50Hz
Cable Shape Round
Conductors Stranded, round, compressed aluminium acc. to IEC 60228 class 2, longitudinally watertight
Inner semi-conducting layer Extruded
Conductor Insulation XLPE, nom. thickness = 9,0 mm
Outer semi-conducting layer Bonded
Longitudinal water tightness Semi conducting water blocking tape
Annealed copper wires in contact with aluminum tape
Radial water blocking Aluminium laminate adhering to outer sheath
Ripcord Aramid
Outer Sheath Halogen free compound, black
Example of marking on sheath AXQJ-TT Pure TSLI 52kV 1x150 AFR/35 DRAKA "Date and time", metre marked

Temperature
Maximum operating Temperature 90 ºC
Temparatures at installation [°C] Lowest cable temperature during installation: -20 ºC below 0 ºC special precaution shall be
taken.

Features
Bending radius In fixed installation: 10 x D
When pulling-in: 15 x D
When plowing down: 8 x D

Electrical
Impulse voltage [kV] 250 kV

86 drakakeila.ee We reserve the rightthetoright


We reserve change
to changeas
as aaresult
result of product
of product developmentdevelopment and/or
and/or changes in product changes
standard. in2017-10-16
Data from product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 87
General information_eng.fm Page 49 Thursday, March 13, 2014 10:48 AM

General Information

Cable designations – CENELEC coding system


The new type designations according to HD361, which are intended common system within CENELEC which is a European
eventually to replace the earlier system entirely, are often referred standardisation organisation with the EC and
to as "CENELEC designations". They have been accepted as a EFTA countries as members. The designation is made up of groups
of letters and numbers as shown below.

Standard Cable design Number and


and rated (from insula- cross-section
voltage tion outwards) of condutors

Type of standard Conductor cross-section

A Accepted national standard Protection core


CC-N ¹) Other national standard
H Established standard G With protection core
S ²) Special standard X Without protection core

Rated voltage Number of conductors

00 (<100/100V)³)
01 (≥100/100,<300/300 V) Conductor form
03 300/300 V
05 300/500 V -D Flexible conductor for welding cable
07 450/750 V -F Flexible conductor of a flexible cable
1 (0,6/1 kV) or cord. Class 5
3 (1,7/3 kV) -H Highly flexible conductor of a flexible
6 (3,5/6 kV) cable or cord. Class 6
10 (7/12 kV) -K Flexible conductor of a cable for fixed
20 (14/20 kV) installation
30 (18/30 kV) -R Rigid, round conductor, stranded. Class 2
60 (36/60 kV) -S Rigid, sector shaped, stranded. Class 2
-U Rigid, round conductor, solid. Class 1
Insulation -W Rigid, sector shaped. solid. Class 1
B EP rubber, max 90°C -AR Al, Rigid, round conductor, stranded Class 2
E Ethylene plastics, PE -AS Al, Rigid, sector shaped, stranded. Class 2
G EVA rubber -AU Al, Rigid, round conductor, solid. Class 1
M Mineral material -AW Al, Rigid, sector shaped. solid. Class 1
N2 Special polychloroprene compound
N4 Hypalon CSM Sheath
R EP rubber, natural rubber, max 60°C
S Silicone rubber B EP rubber, max 90°C
V PVC E Ethylene plastics, PE
V2 PVC, For max. 90°C G EVA rubber
V3 PVC, Fors installation at low temperatures J Glass fibre braid
X XLPE N Polychloroprene or similar material
Z Polyolefine, cross-linked LSZH Q Polyurethane
Z1 Polyolefine, thermoplastic LSZH Q4 Polyamide (Nylon)
R EP rubber, natural rubber, max 60°C
Metallic covering
T3 Textile layer (wrapping or tape), imptegnated or not
A4 Aluminium sheat on each core V PVC
A5 Concentric aluminium V5 PVC, extra oil-resistant
C Concentric copper conductors, spiral-shaped Z Polyolefine, cross-linked LSZH
C4 Copper braid over cable body Z1 Polyolefine, thermoplastic LSZH
C6 Concentric copper conductors, wave-shaped
C7 Copper wire screen
C8 Copper screen as C7, on each core
1) The symbol CC is to be superseded by the code for country orgin Example: SE-N10XC7E-AR
according to CENELEC International Regulations. The code for
Sweden is SE.
2) The symbol S is used for special type of cables. This code does
not comply with the CENELEC document HD 361 S2.
3) Rated voltage in brackets is not yet standard in CENELEC.
AXLJ-RMF 12 kV

Prysmian Group. We reserve the right to change as a result of product development and/or changes in standard.

49

88 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 89
Cable Designations used in Sweden Cable Designations used in Norway
A cable code of 2 - 4 letters is used to descriebe the construction.
Extracts from SS 424 17 01 Additional abbrevation for instrumentation cables:
Collective screen = (c)
Letter 1st letter 2nd letter 3rd letter 4th letter 5th letter Individual pair or triple screen = (i)
Core Insulation Sheath or other Design detail or Design detail or The interpretation (per letter) can be read from the table below:
design detail usage usage
1st. letter: 2nd. letter 3rd. letter 4th. letter
A Aluminium Screen of aluminiumfoil and/or
aluminium wire Insulation Bedding / inner sheath Armouring / screen Outer sheath
B Aluminium alloy Flame retardant thermo- Flame retardant thermoplastic Vehicle cable
A Fibre, tight cladded A Aluminium (optional with cor- A Strength member yarn A Yarn + bitumen
free, low smoke) smoke) rosion protection)
B Fire resistant tape + insulation B Corrogated aluminium B Steel tapes, 2 B Hydrocarbon resistant sehath
Lead sheath Connection wire (Halogen-free) (o.w.c.p.)
C Polychloroprene (Neoprene) C Polychloroprene (Neoprene) C Galvanized steel wire braid C Polychloroprene (Neoprene)
Lead sheath PCP, or chlorinated polyethyl- PCP, or chlorinated polyethyl- PCP, or chlorinated polyethyl-
ene - CPE ene - CPE ene - CPE
C Impregnated paper Concentric copper screen Concentric copper screen Impregnated paper Aluminium + Plastics Oil filled cable reinforcement
D Drip free
D D (Longitudinal / Transverse)
D
D Rubber with outer
rubber sheath E Polyethylene - PE E Polyethylene - PE E Oil filled cable reinforcement E Polyethylene - PE
Polypropylene - PP Polypropylene - PP (Transverse only) Polypropylene - PP
E Copper, solid Ethylene propylene Reinforced design Reinforced design
(class 1) rubber PE or PP + Bedding or taping Flat steel wire armour Semi-conducting PE
Copper, stranded Braid of copper wire Braid of copper or steel wire
F F F F
F (class 2) filling compound (Halogen-free)
H Silicon rubber Lift cable Suspension cable
G Polyamid - PA G G G PE + PA
I Polyurethane Polyurethane
H Chlorosulphonated H Chlorosulphonated H Steel tape + H Chlorosulphonated
Steel wire Steel tape armouring For laying in ground polyethylene - CSP polyethylene - CSP steel wires polyethylene - CSP
J Thermoplastic compound (Hal- Thermoplastic compound (Hal- Steel tapes, 4 o Thermoplastic compound (Hal-
I ogen-free)
I ogen-free)
I I ogen-free)
K PVC PVC PVC PVC
K Paper K Lead K Steel wire, plastics or rubber K Lead
L Polyethylene (PE) Screen of plastic coated Polyethylene (PE) Polyethylene (PE) coated
aluminium tape ev. together with Air + plastics Aluminium laminate + plastics Aluminium (laminated to
screen of copper L (Coaxial cable)
L sheath
L outer jacket)
L
Polyethylene (PE) Expanded PE or PP + Polyester Polyester
M filling compound
M M M
M Copper, stranded Impregnated paper Polyurethane Steel (laminated to outer Polyurethane
N N N jacket)
N
O Chloroprene rubber Chloroprene rubber Oil cable
O Impregnated paper, O Lead + Plastics O Copper wire braid O
Galvanised steel tape Galvanised steel tape oilfilled cable (Tinned or bare)
P armouring armouring Polyvinylchloride - PVC Polyvinylchloride - PVC Phosphorbronze wire braid Polyvinylchloride - PVC
P P P P
Q Halogen free plastic Flame retardant thermoplastic Flame retardant thermo-
Q Fibre in loose tube Q Q Steel wires + counter steel Q
smoke) gen free, low smoke) tape (optional)
R Ethylenepropylene rubber - R Ethylenepropylene rubber - R Steel wires (round) + R Ethylenepropylene
EPR EPR filling compound rubber - EPR
R Plastic coated aluminium tape Control cable
5) armouring S Silicone rubber S Bedding or taping + S Concentric conductor (Screen) S Silicone rubber
concentric conductor
S Self-supporting Cross-linked polyethylene XLPE PE + aluminium wire + Cross-linked polyethylene
(class 6) T T steel tape
T T XLPE
T Heavy connection cable or Steel wire armouring Halogen-free thermoset com- Halogen-free thermoset com- Halogen-free thermoset com-
galvanised steel wire U pound EMA or EVA
U pound EMA or EVA
U U pound EMA or EVA
armouring
V Fibre, slotted core V Aluminium screen V Double wire armour V Other halogen-free
U Without outer sheath (two layers) thermoset materials
W Other materials W Other materials W Catenary wire W Other materials
V Rubber without outer Ethylene propylene rubber For laying in water For laying in water
sheath No insulation No bedding or equivalent No armour No sheath
Cross-linked PVC, oval cross-section
X X X X
X polyethylene (XLPE) Y Y Screen Y Y
Z Flame retardant cross-linked Flame retardant cross-linked Cable for neon equipment
Z Flour plastics PTFE / FEP Z Flour plastics Z Z Flour plastics
low smoke) smoke)

-J Earth conductor

-O Optical fiber

- OJ Optical fiber and earth conductor

90 drakakeila.ee We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 91
General information_eng.fm Page 53 Thursday, March 13, 2014 10:48 AM G eneral info rmatio n_ eng .fm Pag e 54Thursd ay, Marc h 1 3, 201 4 1 0:48 AM

Cable Designations used in Finland Exceptions to the previous, trademarks:


Designations in the cross-section: SAX™ -W C o v ered c o nd uc to r. A stand ard ized Finnish name fo r this p ro d uc t is PAS.

x Separating the number of phase cores and the cross-section (mm²), for example AXMK
Aerial bundled MV cable, completely watertight
1x300 1 kV SAXKA® -W
+ Product having an external conductor (centre conductor, messenger or auxiliary phase
Fire retardant halogen-free cable (or material)
core), for example AHXAMK-W 3x240+70 20 kV, AHXAMK-WM 3x95+62I 20kV, AMKA AFUMEX®
4x25+35 1 kV
Flexible, cold resistant (-50°C) rubber insulated cable
/ Separating numbers or letters from each other. ATON®
- separates the cross-section of the concentric conductor (metallic screen) from the phase
core, for example MCMK 3x25/16 1kV, AHXCMK-WTC 3x240/35 20kV The nickname and trademark of AHXAMK-W
- separates the cross-section of the aluminium and the steel core in overhead conductors, Wiski™
for example ACSR 54/9 RAVEN
Multi-Wiski™ The nickname and trademark of AHXAMK-WM

The most common letters used in domestic products (current product selection): Wiski Plain™ The nickname and trademark of AHXAMK-WP

A Aluminium or aluminium alloy (for alumiini in Finnish)


- in the beginning of the type designation means Al conductor, for example AXMK (excep-
tion: SAX-W means Al alloy) Aluminium conductor steel reinforced. These overhead conductors have often nickname of
- in the middle of the type designation means Al foil laminate, for example AHXAMK-W ACSR bird, city etc, for example Sparrow, Duck, Savo
- aluminium alloy messenger, for example AMKA
- aluminium alloy armouring, for example AHXLKAJ-W AACSR Aluminium alloy conductor steel reinforced (overhead conductor)

Copper conductor (no A letter in the beginning), for example MCMK, XMK, HXCMK-WTC AAC All aluminium conductor (overhead conductor)

- plastic insulation (general expression), for example MCMK, AMKA.. Usually plastic insu- HK C o p p er c o nd uc to r w ith annealed w ires ( fo r hehkutettu kup ari in Finnish)
M lation is either PVC or PE (for muovi in Finnish)
- plastic sheath (general expression), for example MCMK, AHXAMK-W. Plastic sheath can Steel conductor
be PVC, PE or fire-retardant and halogen-free thermoplastic compound. FE
K Cable, for example XMK, AHXAMK-W (for kaapeli in Finnish) TRL Overhead contact conductor for electric locomotives and trolleys

X XLPE insulation, for example AXMK, AHXAMK-W, AMKA-X, SAX-W (for PEX in Finnish)
Exceptions to the previous, bare conductors, overhead conductors, etc
H - extruded semi-conducting layer below and over the insulation (in MV and HV cables), for
example AHXAMK-W (for hohtosuoja in Finnish) Typical Finnish cable with trade name Wiski™
- sheath made of special material, for example TASH having heat resistant sheath

C - concentric layer of copper wires (metallic screen), for example MCMK, AHXCMK-WTC
- uniform copper layer (Cu helical tape or Cu foil laminate) MCCMK, HXCCMK

S Copper braid, for example LSM-HF

L - lead sheath, for example AHXLMK-W (for lyijy in Finnish)


- marine cable (the 1st letter in the type designation), for example LM-HF (for laiva in Finnish)

P Round steel wire armouring, for example AHXAMKPJ-W

J - a conductor or a lead, for example MMJ, LJST-HF (for johdin in Finnish)


- jute tape layer, for example AHXAMKPJ-W

O Control cable, for example MMO (for ohjaus in Finnish)

CHB Metallic screen having Cu wires, semi-conducting tape layer and Al foil laminate, for
example HXCHBMK. The cross-section of the metallic screen given in type designation is
solely based on the cross-section of Cu wires.

CA Metallic screen having Cu wires, semi-conducting tape layer and Al foil laminate, for
example AHXCAMK-W. The cross-section of the metallic screen given in the type designa-
tion is a total cross-section of Cu wires and Al foil laminate combined.

Y Each phase core having a separate metallic screen (in a 3-core cable), for example HXYL-
MKPJ-W 3x95 10kV. This letter is not used with 3-core cables having Al foil laminate only
(AHXAMK-W).

FR Fire Resistant cable remaining functional during fire, for example FRHF

T Heat resistant, for example TASH, AMKA-T

E Cable having a special feature compared to standard cable, for example XMKE 1x300 1kV
having a flexible Class 5 conductor (for erikoinen in Finnish)

92 drakakeila.ee We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 93
Conductor resistances in installation cables and power cables pursuant to EN 50228 Flexible conductors, Class 5
Solid conductors, Class 1

Max conductor resistance at 20°C


Max wire diameter in the
Max conductor resistance at 20 °C Rated area mm2
conductor mm Uncoated
Tinned wires Ω/km
Rated area mm 2
Round copper conductors Round aluminum conductors wires Ω/km
0.5 0.21 39.0 40.1
Uncoated Ω/km Tinned Ω/km Ω/km 0.75 0.21 26.0 26.7
0.5 36.0 36.7 - 1 0.21 19.5 20.0
0.75 24.5 24.8 - 1.5 0.26 13.3 13.7
1 18.1 18.2 - 2.5 0.26 7.98 8.21
1.5 12.1 12.2 18.1 4 0.31 4.95 5.09
2.5 7.41 7.56 12.1 6 0.31 3.30 3.39
4 4.61 4.70 7.41 10 0.41 1.91 1.95
6 3.08 3.11 4.61 16 0.41 1.21 1.24
10 1.83 1.84 3.08 25 0.41 0.780 0.795
16 1.15 1.16 1.91 35 0.41 0.554 0.565
25 0.727 - 1.20 50 0.41 0.386 0.393
35 0.524 - 0.868 70 0.51 0.272 0.277
50 0.387 - 0.641 95 0.51 0.206 0.210
70 0.268 - 0.443 120 0.51 0.161 0.164
95 0.193 - 0.320 150 0.51 0.129 0.132
120 0.153 - 0.253 185 0.51 0.106 0.108
150 0.124 - 0.206 240 0.51 0.0801 0.0817
185 - - 0.164 300 0.51 0.0641 0.0654
240 - - 0.125 400 0.51 0.0486 0.0495
300 - - 0.100 500 0.61 0.0384 0.0391

Stranded conductors, Class 2 Flexible conductors, Class 6

Max conductor resistance at 20°C


Min number of wires per conductor Max conductor resistance at 20°C
Aluconduc- Max wire diameter in the
Copper conductor Rated area mm22
Rated area tors conductor mm
mm2 Uncoated
Round conductors, Tinned wires Ω/km
non-compr.
Round conductors Shaped conductors Uncoated Tinned wires Uncoated, wires Ω/km
wires Ω/km Ω/km plated Ω/km 0.5 0.16 39.0 40.0
Cu Al Cu Al Cu Al
0.5 7 - - - - - 36.0 36.7 - 0.75 0.16 26.0 26.7
0.75 7 - - - - - 24.5 24.8 - 1 0.16 19.5 20.0
1 7 - - - - - 18.1 18.2 - 1.5 0.16 13.3 13.7
1.5 7 - 6 - - - 12.1 12.2 - 2.5 0.16 7.98 8.21
2.5 7 - 6 - - - 7.41 7.56 - 4 0.16 4.95 5.09
4 7 7 6 - - - 4.61 4.70 7.41 6 0.21 3.30 3.39
6 7 7 6 - - - 3.08 3.11 4.61 10 0.21 1.91 1.95
10 7 7 6 - - - 1.83 1.84 3.08 16 0.21 1.21 1.24
16 7 7 6 6 - - 1.15 1.16 1.91 25 0.21 0.780 0.795
25 7 7 6 6 6 6 0.727 0.734 1.20 35 0.21 0.554 0.565
35 7 7 6 6 6 6 0.524 0.529 0.868 50 0.31 0.386 0.393
50 19 19 6 6 6 6 0.387 0.391 0.641 70 0.31 0.272 0.277
70 19 19 12 12 12 12 0.268 0.270 0.443 95 0.31 0.206 0.210
95 19 19 15 15 15 15 0.193 0.195 0.320 120 0.31 0.161 0.164
120 37 37 18 15 18 15 0.153 0.154 0.253 150 0.31 0.129 0.132
150 37 37 18 15 18 15 0.124 0.126 0.206 185 0.41 0.106 0.108
185 37 37 30 30 30 30 0.0991 0.100 0.164 240 0.41 0.0801 0.0817
240 61 61 34 30 34 30 0.0754 0.0762 0.125 300 0.41 0.0641 0.0654
300 61 61 34 30 34 30 0.0601 0.0607 0.100
400 61 61 53 53 53 53 0.0470 0.0475 0.0778
500 61 61 53 53 53 53 0.0366 0.0369 0.0605
630 91 91 53 53 53 53 0,0283 0,0286 0,0469
800 91 91 53 53 - - 0,0221 0,0224 0,0367
1000 91 91 53 53 - - 0,0176 0,0177 0,0291
1200 1) 0,0151 0,0151 0,0247
1) The minimum number of wires is not specified for these conductor areas. These areas may be designed with 4, 5 or 6 segments of equal size (Milliken).

94 drakakeila.ee We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 95
General information.
General terms and conditions of supply
Unless agreed otherwise, the ”General Terms and Conditions Marine cable laying
of Supply NL09” are applied. Standard cables are normally used in shallow water with good temperature of approx. +70°C at the rated current. If cooling 1. Minimum cable temperature during cable laying
bottom conditions and low level of water movement. The of the cable is complicated by a heat-insulating layer such as
Length tolerances Cable type Temperature °C
worst risk of operation disturbances in these installations sawdust or pulp, the conductor and sheath temperatures can
Installation cables, standard length: ± 3% is external mechanical damage to land fixtures and anchor. reach +125°C and +100°C, respectively. At this point, there is a AXQJ, FXQJ, N1XZ1, -10
Therefore, the cable shall always be marked with signs risk of deformation of the insulation and sheath layers which AXALJ-TT, AXLJ-RMF, AXQJ-RMF, AXLJ-TT TSLF -20
Rubber cables, standard length: ± 5%
Power cables, standard length: + 3% –2% and protected mechanically at the land fixtures. In deeper leads to disruptive discharge in the cable.
water or unfavourable or unknown bottom conditions where
In case of open laying of single-conductor cables, the cables 2. Minimum bending radius
Reel label better mechanical protection is desired, the cable should be
reinforced. Additional fixing may also be necessary to keep shall be bound together and fixed to the base surface to avoid At At
The reel label is supplied with large, distinctive text and a bar Cable type At fixing
the cable in place in areas with strong currents, using e.g. them being thrown apart at short-circuiting. Otherwise, thick laying ploughing
code for faster and safer handling of goods, also at the clients’
sandbags or similar. cables exposed to high short-circuit currents may be damaged
sites. The bar code system chosen by us (code 39) is an AXQJ, FXQJ-EMC, FKKJ, N1XE / -Z1
or damage their surroundings. Single-conductor cables are Single-conductor 1kV 15 x D 8xD 10 x D
alphanumeric bar code with a high safety level. The image
Cable ploughing normally laid close together in a triangle form which both Multiconductor 15 x D 8xD 8xD
below shows an example of a reel label. The actual labels are at
Cable ploughing methods have been developed within the facilitates the “trussing” and reduces shield losses which in
least 160 mm wide. AXQJ, FXQJ, AXALJ-TT,
latest years and entail that cable installation costs have its turn affects the load capacity. In order to improve the load AXLJ-TTCL TSLF, AXLJ-RMF 15 x D 8xD 10 x D
decreased compared to traditional cable laying with trenching. capacity in connections with single-conductor cables, shield Single-conductor 12 - 36kV Multiconductor 12 x D 8xD 8xD

Observe the following for successful cable ploughing losses can be minimized in exceptional cases with various
installation: methods. The simplest way is to only earth the metal shields r
of the cables in one end of the connection, open shield. Instead D = Outer diameter of the cable D
Cable ploughing is generally considered to be a “rough”
of an induced shield current which causes losses, an induced
installation method for cables. Uncautious handling may
voltage is achieved between the insulated shield end and
damage the cables due to rocks and other sharp objects in the
earth. This voltage is directly proportional to the length of the
ground pressed into cable sheaths. The planned installation
connection and the conductor current and can be dangerous 3. Sealing of cable ends
route shall always be ploughed in advance to ensure that cable
to people. Therefore, open shield is only recommended for
installation is possible along the planned route. Choose a cable The cable ends shall be sealed against moisture after each cutting.
short connections (< 100 m) and preferably in protected areas The cut length shall alsi be sealed if it is not installed immediately.
type intended for cable ploughing. Generally, cables with
(substations, equipment rooms etc.). Note that in case of
polyethylene (PE) outer sheath has the required mechanical
single-point earthing, the insulation between the shield and
strength. Halogen-free, fire-retardant sheath can be ploughed
the system earth shall be checked prior to commissioning. 4. Maximum pulling force
if required caution is observed. Outer sheaths have different
Earth faults may cause electric arcs and fire hazard. Pulling equipment Pulling force
mechanical characteristics at different temperatures which
Recommendations for cable laying can be crucial for whether a cable installation will Fire sealing Immediate connection in all conductors Aluminium P = 30 N/mm2
General be good or less good. A cable installed on a warm summer day Copper P = 50 N/mm2
Fire sealing of lead-throughs is necessary in order to reduce the Cable grip on the cover P = 5 x D2 Newton
Cable laying environments and cable types vary widely. This at +30°C ambient temperature can show different
performance from the same cable installed at an ambient risk of fire spreading between different parts of the building
section provides brief advice and recommendations for
temperature of +10°C. The choice of machines and equipment through cable connections.
different operations during cable laying. The cable weight 5. Maximum permissible surge current in three-phase cables (kA)
often determines the laying method. In case of cable laying is also crucial for the final result. Experience has shown that This also applies during the entire construction period. A proper Rated voltage Rated voltage
machines and equipment used for cable laying require similar Area Area
in ground, one can choose between pulling, driving and fire sealing should prevent fire from spreading between fire mm2 mm2
service and maintenance as all other equipment. Faulty or 1kV 12-24kV 1kV 12-24kV
ploughing. If the area is easily accessible for vehicles, driving is compartments during the whole course of the fire – fire
an easier and more cable-friendly method. Tractor excavator damaged equipment can easily destroy many metres of cable. 50 45 55 150 60 70
development and extinguishing – i.e. it shall
70 50 60 185 60 70
is often used for reel weights of up to approx. 1 tons, where
Other • Meet the requirements of the fire class: be type approved. 95 55 65 240 60 70
the cable reel hangs from the bucket. Heavier cables are driven
with crane truck or a vehicle for lift dumpers. For cable pulling, Cable ladders are practical aids for cable laying both indoors 120 55 65 300 60 70
• Withstand smoke, gas and extinguishing media during the
cable reels are placed evenly distributed along the cable and outdoors. Power cables are preferably installed with a
fire.
route so that the cable runs freely. Pulling can be performed slight distance between cables for efficient cooling. Lashing 6. Testing voltage for 12-36 kV cables after laying
manually or with a machine. The reel shall be possible to wire should be used with caution to avoid any cuts • Withstand fire restoration after the fire
AC
brake during cable laying, driving as well as pulling. There • Be easily installed and allow modifications. Voltage kV Insulation type
in the sheath, especially in case of vertical cable laying. Sheath kV Time
are detailed manuals for ground installation indicating the
damage may also occur in long horizontal cable connections • Withstand loads normally occurring in the installation, during New cable
installation depth, cable protection, marking and combined
fixed with lashing wire, due to temperature changes. Clamps installation
laying with telecommunication cables in SEK Manual 429. both operation and standby 12 PEX 12 5 min
are less harmful to cable sheaths and should therefore be
The organization EBR (El Byggnads Rationalisering, Rational 7 24 h
preferred for somewhat heavier cables and sheaths that can
Electrical Installation) has issued a manual for cable laying for 24 5 min
reach very high temperatures. Heat may originate both from 24 PEX
max 145 kV (KJ41:09). Another norm, SS 424 14 38, regulates 14 24 h
the environment and from load losses in the cable. XLPE
cable laying in buildings and culverts. Sharp bends can be 36 5 min
cables installed on ladders with uninhibited air circulation 36 PEX
18 24 h
critical moments during pulling and permanent installation,
achieve a conductor temperature of +90°C and a sheath
high tensile stresses and laying at low temperatures.

96 drakakeila.ee We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 97
Testing after cable laying Sheath current can also be identified with a megger. The
formula for sheath current is then:
Drum dimensions and weights
All cables are subjected to routine testing according to the
applicable standard at the factory before the reels are delivered
I = U / (RxL)
to the client. In order to check the dielectric strength after
transport and cable laying, a new test shall be conducted by the where I is the sheath current per length unit (A/km), U is the
installer or the owner of the installation prior to commissioning applied voltage (V), R is the detected sheath resistance (Ω)
of the cable. The test standard SS 424 14 17 for PEX cables and L is the cable length (km).
indicates the method, voltage and time that can be applied in
testing. Tests may also prove necessary in technical assessment Sheath test, measurement setup
of older installations. Ensure that a reasonable test voltage is
• S
 trip 10 cm of the semiconductive sheath from both the
chosen, taking the general condition of the installation into
inner and the outer end of the sheath.
account. Prior to testing, it is important to ensure that the parts
of the installation which are not to be tested are disconnected • C
 onnect the instrument between the semiconductive layer
and earthed. Then the voltage test is performed with the of the sheath and the copper shield.
voltage indicated in the regulations. After testing, it is
important to earth the installation to ensure that the • Adjust the instrument to read the leakage current ”I”.
installation and testing equipment are properly discharged.
Maintain earthing until the cable is commissioned or for at least • Start by applying 100 V.
3 hours.
• Increase the test voltage gradually.

Sheath testing in medium voltage cables • Discontinue the test if a fault is detected.

Network owners set high requirements on the quality of • I f no fault is detected during the voltage increase, continue
execution of cable installations. Many power plants require to the test voltage within a minute.
improved quality assurance for this work. The possibility of
checking the sheath on medium voltage cables both before and Note! When measuring a cable on reel, ensure that the inner
after installation has therefore come into focus. This contributes end is freed, dry and stripped to at least 10 cm to avoid
to better safety for the network owner as well as the external conduction due to moisture/water. Carrying
Drum Dimensions, mm Weight capacity
contractors often used for laying cables and installing them in
Interpretation of measurement results type A B C D E kg/drum kg
the ground.
Suitable test voltages and acceptable leakage currents for K6 600 468 250 400 75 12 300
The advantage of the semiconductive outer layer is that the
different sheath materials are indicated below. An aged K7 700 580 325 500 75 20 400
cable can be tested for sheath faults before the cable trench is
sheath may show up to 1000 times higher leakage currents K8 800 580 375 500 75 25 500
closed. If a fault is detected, it can be repaired in an early stage,
than a new one without being faulty, and still be approved,
saving both time and money. Cable testing of cables installed in K9 900 630 425 550 75 34 600
depending on the installation conditions.
pipes is another positive side of choosing this cable. 9FV 900 675 425 550 82 50 700

K10 1000 712 500 600 75 54 800


Measurement of sheath current
K11 1100 762 575 650 106 55 850
Required instrument: high voltage generator (DC) with a precise Test Newly installed cable Max leakage 11GV 1100 755 500 600 82 85 1000
Sheath
ammeter for measuring the output current. The voltage shall voltage current, repeat
material K12 1200 982 675 850 106 90 1500
be adjusted gradually from 0 to the maximum of 5 kV to avoid (kV, DC) Rec. max leak- Max leakage, measurement
age current note 13G 1300 760 600 600 82 105 1600
indication of several sheath faults at the same time. The largest
PE 5 10 μA/km 1 mA/km 1 mA/km K14 1400 982 800 850 106 115 2000
faults are then detected first. The measurement voltage
PVC 2 0,5 μA/km 10 mA/km 50 mA/km
depends on the type of sheath material. For our AXLJ-TTCL with 15G 1500 760 700 600 82 150 2000
LSZH* 2 2 mA/km 50 mA/km 500 mA/km
PE (Polyethylene), the maximum measurement voltage is 5 kV. * LSZH halogen-free and flame-retardant sheath K16 1600 1018 950 850 106 195 2500

SELCABLE, 2012, / Available at: [www] http://www.selcable.se/$-1/file/- K18 1800 1075 1100 850 132 230 3000
selc-11-005-mantelprovning.pdf [2015-07-20] K20 2000 1190 1300 1000 132 340 3500

K22 2200 1190 1400 1000 132 410 4500

Repairing sheath damage K24 2400 1205 1400 1000 132 450 5000

When repairing sheath damage, 10 cm of the conductive K26 2600 1448 1500 1200 132 900 10000
10 cm 10 cm
layer shall be stripped from each side of the edges of the K28 2800 1610 1500 1300 132 1180 12000
hole/damage. This ensures that no erroneous indications are K30 3000 1800 1500 1500 132 1500 13000
received during repeated testing after the repair. To maintain
the special function of the conductive layer after repair and
testing, a temporary connection should be made over the
non-conductive repair with e.g. a copper net.
Always consult your supplier of joint/repair sets for
recommendations.

98 drakakeila.ee We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 We reserve the right to change as a result of product development and/or changes in product standard. Data from 2017-10-13 drakakeila.ee 99
Drum handling guide
The right way to transport, handle and move drums

A cable is a valuable product. The cable transportation package drum. Keep the drum from touching other drums and well balanced. Secure the drums firmly Fasten the drums firmly
is usually a drum. The battens on the drum seem thick enough to Take care not to give any impact to the drum being lowered. In case
remain unbroken. But, with a cable weighing more than 4 tons, it a cable drum must be temporarily in a waiting position above the The round-shaped cable drum rolls easily. It is an a very unstable The drum is fastened to the base through the centre hole or across
deck for reason of cargo handling, keep it hoisted and do not put it
becomes very vulnerable. If the handling is done correctly, the drum state because its center section is vacant and the whole weight rests the flanges with wires or ropes.
down on the deck.
will protect the cable from transportation damages. If the drum is on its peripheral section. Make sure to use drags to prevent drums
damaged, the cable can also be damaged. The damage might not from rolling during storage. Large drums should be lifted from the
be discovered until after installation, when repairs can be extremely base onto triangular or square wedges. The wedges should be posi-
expensive. tioned by the flanges or the full width of drum. Sideways movement
is eliminated by planks attached to the side of the drum. In case
The purpose of these instructions is to tell you how damages can be smaller drums are placed between larger ones, each drum has to
avoided by correct drum handling. be supported separately to prevent damages.

Keep the drum upright Avoid stacking

Always store and move the drum in an upright position. The drum is Stacking of drums should be avoided. If, however, one is forced to
constructed to be handled in an upright position - it will not stand up do this, same size of drums should be positioned exactly on top of
to being lifted lying flat. When kept upright, the cable layers will not each other.
entangle and cause problems when the cable is laid. Keep the cable Handling with fork-lift truck If smaller drums are stacked on larger drums, planks of the size of
protected until the cable is used. the larger drum is placed in between to protect the flanges. Above
The forks of the truck must be longer than the width of the drum, so method is recommended even when same size drums are stacked.
that the lagging is not damaged. Different widths of drums should
be painted on the forks enabling the operator to select the correct
position for the drum size. When moving the drum, tilt the truck
mast so that the drum remains in the fork and the points don’t touch
the ground. Raise the forks of the forklift sufficiently 15-20 cm above
the ground. Insufficient raising may cause the drum to be dragged
on the ground and eventually damaged or dropped off the forks if
the ground surface is uneven. Don’t release the drum until the truck
has sopped completely. Don’t push the drum with the truck. Leave
sufficient room between each drum so that the fork doesn’t damage
the drum.

Roll in direction of arrows only


Secure drums to be transported
Always roll the drum in direction of the arrow. This way the cable will Don’t drop drums
not unwind and loosen on the drum. But, this does not mean that To prevent movement of drums, a combination of wedges and
the drum can be rolled freely. When the drum must be rolled for The drum must not be dropped from the vehicle. The drum is to be
transportation support should be used and tied down front and rear.
some reason or other, roll it in the direction of arrow over a distance lifted either by winch of fork-lift truck as mentioned in “lifting the
Higher drums should be tied in side direction as high up as possible.
not exceeding 5 meters. If it is rolled beyond the 5 m limit, the cable drum”. If above mentioned equipment is not available, best possible
wind will come too tight and cut off the rope holding the cable end. conditions must be created to unload the drums from the vehicle. A
The drums loaded first should rest against the front board (observ-
This will deform the cable and make it unfit for use. platform of the same height as the vehicle or a point in the terrain
ing shaft weight). If the last drum doesn’t lean against the end board
will guarantee that no damage will occur. Make sure when unloading
or the board is not strong enough, the drum must be secured.
that the drum doesn’t strike another drum.
Nail with caution

In case the planks have to be refastened, the nailing should be done


carefully in the middle of the drum flange. If label or something
similar is attached to the drum with nails, make sure that they don’t
touch the cable.

age
Lift the drum without damage

When lifting the drum, use a shaft through the centre of the drum
and a wire spreader. If these are not available, lift with as long a
wire as possible, so that the sides of the drum are not damaged.
Make sure that the cable head is not pinched between wire and

100 101
Draka Keila Cables AS
Paldiski road 31
76606 Keila
Estonia
T +372 674 7466
www.drakakeila.ee

© by Draka Keila Cables AS 2017

Issue: December 2017

The preparation of text and illustration has been carried out with great care. Nevertheless mistakes can not be excluded. All photographs are the
exclusive property of Prysmian Group.

Prysmian Group does not accept any liability for casual or consequential damage in connection with the use of this catalog. Improvement
proposals and advices are to be sent to the above address.

All rights reserved. This document may not be copied in whole or in part, be reproduced, translated into another language or stored on electronic
media.

Please note: Prysmian Group herewith warrants that the delivery items contained in this catalogue will be of the agreed nature and quality upon
passing of the risk. Aforementioned nature of the delivered items shall be exclusively rated and measured by the sales and purchase agreements
made in writing between Prysmian Group and the purchaser about nature and quality, properties and characteristic performance features of
the respective delivery item. Illustrations and information contained in catalogues, price lists and other information material disclosed to the
purchaser by Prysmian Group as well as any information describing the product shall be only legally binding, if expressly being referred to as
binding information. Under no circumstances, such information shall be taken as guarantee for the special quality or nature of the delivery item.
Such quality guarantees must be explicitly agreed upon in writing. Prysmian Group herewith reserves the right to modify the content of the
catalog at any time.