You are on page 1of 13

HCPT Project: Model Site BTS Outdoor (3900A-303)

Confidentiality Level: For Internal use only

Model Site: Cidodol Site (BTS3900A-303)

Overview of outside the cabinet Overview of outside the cabinet


(front closed door view) (front open door view)

Overview of outside the cabinet Overview of outside the cabinet


(closed side view) (back view)

__________________________________________________________________________ 1
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of ACPDB AC phase cable with label

Include spring washer,


and flat washer

Jumper-Feeder with color ring Bolt at cabinet and U beam


and yellow plat label tightly tightened

__________________________________________________________________________ 2
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of APM 30 Cabinet Overview of RFC Cabinet


(Rectifier,PDU,BBU,OVP,IDU) (GRFU and CPRI cable laying)

Load information:

Load 3 battery power door alarms


Load 4,5,6,7  IDU power depend on IDU type

(RTN 620  15A, RTN605  @5A)

Overview of E1 for DDF and IDU Overview of additional equipment


inside BTS include its spare at PDU fuse DC

__________________________________________________________________________ 3
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of Inside-outside cable Overview of AC phase cable


blocked labeled inside BTS

Overview IDU position and Overview of IDU power cable


Coax cable laying with label

__________________________________________________________________________ 4
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of IDU grounding Overview of coax lying with label


at BTS body

Overview of CPRI connection at Overview of CPRI connection at


GTMU board with label GRFU board with label

__________________________________________________________________________ 5
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of Jumper label inside BTS Overview at cable conduit through


with label and blocking inlet in the cabinet

Overview of battery cabinet Overview of battery cable blocked


(open side view) (inside battery cabinet)

__________________________________________________________________________ 6
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of battery power cable Overview of PGND cable


connection at the terminal battery at battery cabinet

Load 3

Battery power cable monitor at battery rack connected to load 3

__________________________________________________________________________ 7
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of PGND cable at Overview of cable laying


PGND bus bar

Overview of temperature alarm Overview of door PGND cabinet


Sensor inside the battery cabinet

__________________________________________________________________________ 8
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of PGND cable and bar Overview of battery cable power


interconnection

Overview of outside the cabinet Overview of outside the cabinet


(closed side view) (back view)

__________________________________________________________________________ 9
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Comm. Port from rectifier (COM_485) connected to (COM_IN) port at battery


door

Overview of crane handles replacement Overview of Battery cable


must install plastic blocker bolt connection

__________________________________________________________________________ 10
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

ALARM LSA PGND


3G Link LSA

2G LINK LSA

DDF installed between BBU and RTN board. From left both LSA use for Alarm
connection, up middle and right LSA for 3G link connection, bottom middle and
right LSA for 2G link

Overview of arrester alarm cable Overview of phase alarm cable


at ACPDB at ACPDB

__________________________________________________________________________ 11
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of Microwave antenna Overview of microwave antenna


support Tightly tightened with ODU

MUST scratch the metal paint


before connect to tower body

Overview of ODU PGND connected Overview of ODU PGND


to near metal (tower) connected tightly

__________________________________________________________________________ 12
Huawei Confidential. No enclosure without permission
HCPT Project: Model Site BTS Outdoor (3900A-303)
Confidentiality Level: For Internal use only

Overview of coax PGND clip Overview of coax waterproofing


tightly connected to bus bar with label

Prepared by Gde Agus Saputra

__________________________________________________________________________ 13
Huawei Confidential. No enclosure without permission

You might also like