You are on page 1of 26

Manufacturer since 1993

needles
Interventional
and diagnostic

CIM REV5 11/01/2014


2/26
3/26
CIM REV5 11/01/2014
BONE MARROW BIOPSY
PenBone
Needle for sternal or iliac crest
marrow aspiration, light version

PenBone needle (PI) is a disposable device for sternal or iliac aspiration


with high reliability performance. PI needle is equipped with an atraumatic can-
nula with Chiba type sharpening that has been made of AISI 304 stainless steel
tempered in accordance with international standards.

The needle has an adjustable safety stop that allows to easily determine, thank also to
the centimeter markings on the cannula surface, the length of the cannula and the depth of
insertion.
The stylet, is coupled to the handle by a “bayonet” attack to avoid its
moving back during introduction.
The needle has a Luer-lock that allows the attachment of the syringe for a safety and fast
aspiration of the bone marrow. The perfect matching between cannula and stylet, offers a safe
penetration in the cortical bone.
The tip shape is designed to facilitate the needle insertion keeping high mechanic
strength.
On the handle has shown the gauge size of the needle.

The removable depth


stop, allows to use the device
in its maximum length.

Code Gauge Minimum Maximum


length length
PI1535/100 15G 35 mm 100 mm
PI1525/90 15G 25 mm 90 mm
PI1510/75 15G 10 mm 75 mm
PI1635/100 16G 35 mm 100 mm
PI1625/90 16G 25 mm 90 mm
PI1610/75 16G 10 mm 75 mm
PI1835/100 18G 35 mm 100 mm
PI1825/90 18G 25 mm 90 mm
PI1810/75 18G 10 mm 75 mm

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
4/26
CIM REV5 11/01/2014
BONE MARROW BIOPSY
ILLY
Needle for medullar aspiration
with ergonomic handle

Illy needle (PIL), is a disposable device for high reliability performance of medullar
aspiration.
The device is equipped with an atraumatic cannula with Chiba type sharpening made
of AISI 304 stainless steel tempered in accordance with international standards.

Illy has an adjustable safety stop that allows to easily determine, thank also to the centi-
meter markings on the cannula surface, the length of the cannula and the depth of insertion.
The stylet is coupled to the handle by a “bayonet” attack to avoid its
moving back in course of introduction.
The needle has a Luer-lock the allows the attachment of the syringe for a safety and fast
aspiration of the bone marrow. The perfect coupling between cannula and stylet, offers a safe
penetration into the cortical bone.
The tip shape is designed to facilitate the insertion of the needle into the bone, keeping the
mechanic strength. The “T” ergonomic handle offers optimal pressure and secu-
re grip to facilitate the penetration step into the cortical.
On the handle has shown the gauge size of the needle.

Code Gauge Minimum Maximum


length length
The removable depth PIL1410/75 14G 10 mm 75 mm
stop, allows to use the device PIL1535/100 15G 35 mm 100 mm
in its maximum length.
PIL1520/85 15G 20 mm 85 mm
PIL1510/75 15G 10 mm 75 mm
PIL1635/100 16G 35 mm 100 mm
PIL1620/85 16G 20 mm 85 mm
PIL1610/75 16G 10 mm 75 mm
PIL1835/100 18G 35 mm 100 mm
PIL1820/85 18G 20 mm 85 mm
PIL1810/75 18G 10 mm 75 mm

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
5/26 5/26
CIM REV5 11/01/2014
BONE MARROW BIOPSY
OsteoJ
Bone marrow biopsy needle

OsteoJ is a device for bone tissue biopsy, provided with ergonomic handle to distribute in an optimal way, the
pressure applied by the operator during the introduction in the cortical bone. The needle is equipped with a cannula
made of AISI 304 stainless tempered steel in accordance with international standards. The centimeter markings on the
cannula surface, allow to easily determine the depth of insertion into the bone tissue. The special sharpening at “fish
mouth” of the needle tip, improves the penetration capacity establishing a perfect cylindrical cutting that maintains
intact the sample architecture.

OsteoJ needle is equipped with a


security system with rotation coupling
which avoids the moving back risk of the
stylet during the insertion step.

The extraction wire has a mea- OsteoJ needle is equipped with a stylet with trocar pyramidal
suring function of the specimen quantity tip to allow a quick and less invasive penetration into the cortical.
present into the cannula and offers added On the packaging is stamped the needle diameter with internatio-
safety for biopsy specimen extraction. nal color code.

Code Gauge Length Color


The handle is provided with a sharpe- code
ned Luer-lock to offer a more safety
attachment to the syringe. Aspiration can PJ1306 13G 60 mm cyan
be performed at any step of the PJ1310 13G 100 mm cyan
procedure.
PJ1110 11G 100 mm white
PJ1115 11G 150 mm white

The set includes: PJ0810 8G 100 mm green


-extraction wire to insert into the cannula tip
-Luer-lock cap (on the handle) to avoid the blood loss during the
extraction step.

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
6/26
CIM REV5 11/01/2014
BONE MARROW BIOPSY
PickUp
Bone marrow biopsy needle without luxation

PickUp (PJT) is a device for bone tissue biopsy provided with an external trap system that
allows the tissue extraction without luxation. The ergonomic handle is designed to distribute in an
optimal way, the pressure applied by the operator during the introduction into the cortical bone.
The cannula of the needle, made with high quality stainless tempered steel, shows on its surface,
centimeter markings that allow to easily determine the insertion depth into the bone tissue. The
special “fish mouth” sharpening of the needle tip, improves the penetration capacity, establishing
a perfect cylindrical cutting that maintains intact the architecture of the sample.

PickUp needle is equipped with a security system


with rotation coupling which avoids the moving back
risk of the stylet during the insertion. The handle is
provided with a sharpened Luer-lock to offer an ad-
ded safety attachment to the syringe. Aspiration can
be performed at any step of the procedure.

PickUp needle is equipped with stylet with pyramidal trocar tip that allows a quick and less invasive
penetration into the cortical. The device is provided with an extraction wire with a measuring function of
the specimen quantity present into the cannula, and offers added safety for biopsy specimen extraction.
The needle diameter with international color code is stamped on the packaging.

PickUp needle offers more benefits than a traditional Jamshidi needle:


-avoids the complications caused by luxation movement which give pain to the patient
-increases considerably the probability of positive outcome of the procedure
- allows a simpler and safer extraction of the frustol from the needle because the sample is
extracted together with the trap system. Code Gauge Length Colour
code
The handle is provided with a sharpe- PJT1306 13G 60mm cyan
ned Luer-lock to offer a more safety
attachment to the syringe. Aspiration can PJT1310 13G 100mm cyan
be performed at any step of the PJT1110 11G 100mm white
procedure.
PJT1115 11G 150mm white
PJT0810 8G 100mm green

Optionally, Tap system can be supplied with


double spoon (reference PJTD)

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
7/26
CIM REV5 11/01/2014
BONE MARROW BIOPSY
Press-To
Bone marrow biopsy needle without luxation
with internal Trap device

PressTo (PS) needle is a device for bone tissue biopsy provided with an internal trap system that
allows the tissue extraction without luxation. The “T” ergonomic handle offers optimal pressure and
secure grip to facilitate the penetration step into the cortical.
The cannula of the needle is made with high quality stainless tempered steel and the centimeter mar-
kings on its surface, allow to easily determine the insertion depth into the bone tissue. The special “fish
mouth” sharpening of the needle tip, improves the
penetration capacity, establishing a perfect cylindrical cutting (till 3 cm) that maintains intact the
sample architecture.

PressTo needle is equipped with a security sy-


stem with rotation coupling which avoids the moving
back risk of the stylet during the insertion step.

PressTo needle offers more benefits than a traditional Jamshidi needle:


-avoids the complications caused by luxation movement which give pain to the patient
-increases considerably the probability of positive outcome of the procedure
-allows a simpler and safer extraction of the frustol from the needle because the sample is extracted together with
the trap system.

PressTo needle is equipped with stylet with pyramidal trocar point that al-
lows a quick and less
invasive penetration into the cortical. The device is provided with a specimen
pusher with a
measuring function of the specimen quantity, present into the cannula, and of-
fers added safety for biopsy specimen extraction.
The needle gauge with international color code is stamped on the packaging.

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
8/26
CIM REV5 11/01/2014
BONE MARROW BIOPSY
PressTo
Bone marrow biopsy needle without luxation

The handle is provided with a luer Lock connector to offer


an added safety attachment to the syringe.
Aspiration can be performed also after the biopsy procedure.

Code Gauge Length Colour


code
PS1306 13G 60 mm cyan
PS1310 13G 100 mm cyan

PS1110 11G 100 mm white


PS1115 11G 150 mm white
PS0810 8G 100 mm green

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
9/26
CIM REV5 11/01/2014
INTERVENTIONAL RADIOLOGY
EasyLock
Needle for soft tissues biopsy by aspiration as for “Menghini” modified

EasyLock (PC) needle, is provided with an atraumatic sharpened cannula made with AISI
304 steel and a “Menghini” tip. The disposable device is used for soft tissues biopsy such as kid-
ney, lymph nodes, liver and thyroid.
Removable cannula with centimeter markings for a simple insertion depth evaluation.

The sliding stopper allows to easily determine the depth to reach. The internal echogenic
marker enhances the ultrasound visibility
avoiding the cells spread during the biopsy procedure.
The device is provided with internal stylet with the following functions:
-To facilitate the device penetration without skin incision,
-To avoid the tissue penetration into the lumen of the cannula before reaching the target,
- to gradually transmit the created vacuum from the syringe, on the needle tip (thanks to a special pro-
cessing present on the surface of the stylet),
-To avoid the sample aspiration into the cylinder of the syringe, keeping the sample into the cannula and
to facilitate the expulsion step.

The needle is provided with a sharpened Luer-lock to offer an added safety attachment
to the syringe without vacuum loss.

Otpionally NeedleVise®safety device can


be added (PCR code)

Gauge Outer Code Code Code Code Code


diameter length length length length length
70 mm 100 mm 120 mm 150 mm 200 mm
18 1.27 PC1807 PC1810 PC1812 PC1815 PC1820
19 1.10 PC1907 PC1910 PC1912 PC1915 PC1920
20 0.90 - PC2010 PC2012 PC2015 PC2020
21 0.80 - PC2110 PC2112 PC2115 PC2120
22 0.70 - PC2210 PC2212 PC2215 PC2220

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
10/26
CIM REV5 11/01/2014
INTERVENTIONAL RADIOLOGY
EasyCut
Needle for soft tissues biopsy by aspiration as for “Menghini” modified

EasyCut (PC0) needle is a disposable device for soft tissues biopsy such as liver, lymph no-
des, tyroid ans kidney. The needle is provided with an atraumatic sharpened cannula made with
AISI 304 steel and a “Menghini” tip. The stylet has a pyramidal tip. The device is equipped with a
special system for vacuum activation by pressing a button on the syringe; in this way, it is possible
to perform the procedure used one hand.
The device is provided with internal stylet that facilitate the device penetration without
skin incision,avoid the tissue penetration into the lumen of the cannula before reaching the target,
gradually transmit the created vacuum from the syringe, on the needle tip (thanks to a special
processing present on the stylet surface), avoid the sample aspiration into the cylinder of the
syringe, keeping the sample into the cannula and to facilitate the expulsion step.
The sliding stopper on the cannula Gauge Diameter Code Code Code Code
allows to easily determine the depth to reach. length length length length
Internal echogenic marker to enhance the ultra- 70 mm 100 mm 150 mm 200 mm
sound visibility. The needle is
16 - PC01607 PC01610 PC01615 PC01620
provided with a sharpened Luer-lock to offer an
added safety attachment to the 18 1.27 PC01807 PC01810 PC01815 PC01820
syringe without vacuum loss. 20 0.90 PC02010 PC02015 PC02020

EasyCut Coaxial
The needle is provided with a sharpened Luer-
lock to offer an added safety attachment to the sy-
ringe EasyCut Coaxial (PC0C) is a combination of an
EasyCut needle and a coaxial introducer needle with size
and length studied to be exactly coupled to each other.
The introducer may be left in position inside the patient,
allowing the execution of multiple procedures. without
vacuum loss.

Gauge Diameter Code Code Code Code


length length length length
70 mm 100 mm 150 mm 200 mm
16 - PC0C1607 PC0C1610 PC0C1615 PC0C1620
18 1.27 PC0C1807 PC0C1810 PC0C1815 PC0C1820
20 0.90 PC0C2010 PC0C2015 PC0C2020

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
11/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
HandCut
Manual tru-cut needle for soft tissues biopsy with guillotine system

HandCut (PM) needle is a disposable device for soft and fibrous tissues biopsy that need to
be cut for their remotion.
The “Menghini” sharpening of the cannula, allows cutting and acquisition of the specimen. The
stylet has a triple ultra-sharp tip to penetrate easily also into fibrous tissues
and has a 20mm specimen notch for sample capturing.

Sliding stopper and centimeter markings on the cannula, to easily determine the insertion
depth.

The device is equipped with:


- internal echogenic marker to enhance the ultrasound visibility avoiding cells spreading during
the biopsy procedure.
- length limitator to take samples of 10mm in length,
- Luer-lock that allows the connection to the syringe for Cytological aspiration.

Gauge Outer Code Code Code Code


diame- length length length length
ter 75 mm 100 mm 114 mm 150 mm
14 2.10 PM14075 PM1410 PM14114 PM1415
16 1.60 PM16075 PM1610 PM16114 PM1615
18 1.20 PM18075 PM1810 PM1815

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
12/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
Thesy
Ultra-light semiautomatic tru-cut needle for soft tissues biopsy with
guillotine system with non-removable cannula

THESY is a disposable device provided with removable cannula with enhanced echo-visibility made
with AISI 304 steel with a “Menghini” tip that allows an atraumatic precise cutting of the tissue. A sliding
stopper and centimeter markings on the cannula surface allow an easily determination of the depth of
insertion.
The biopsy specimen, can be taken with two different length: 10mm or 20mm.
Thesy, after cannula loading, can be used with a single hand, leaving the other free to handle
other devices such as ultrasound guide etc..
The stylet is equipped with:
-ultra-sharp triple tip to penetrate easily also into fibrous tissues
-a 20mm specimen notch for the sample capture.

Optionally, Thesy, can be provide with a coaxial introducer needle, with pyramidal tip stylet.
Needle size, with international colour code, stamped on the handle of the needle.

Gau- Outer Code Code Code Code Thesy, is the lightest semiautomatic
ge diame- length length length length device on the market; this characteristic
ter 70 mm 100 mm 160 mm 200 mm is very important because allows the
User to leave the device safely inserted
14 2.10 PD01407 PD01410 PD01416 PD01420
into the patient without support it.
16 1.60 PD01607 PD01610 PD01616 PD01620
18 1.20 PD01807 PD01810 PD01816 PD01820

20 0.90 PD02007 PD02010 PD02016 PD02020

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
13/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
Intro
Coaxial introducer needle

Intro (PT) is a introducer coaxial needle used as an


insertion guid of cannulas, biopsy devices, catheters,
breast localization wires or other devices in the human body.
Intro needle allows the execution of multiple procedures
remaining into the patient, while the biopsy needle,
going through the introducer needle, can be unloaded
and reloaded.
Intro is equipped with stylet with trocar tip designed to have a tissue penetration less traumatic as possible.

Stylet hub coloured according to the international colour code.


Universal connector Luer-lock and handle made with transparent plastic material to facilitate the
fluid passage visibility.
Centimeter markings and sliding stopper to easily determinate the insertion depth
with a maximum safety for the patient.

Code Outer Inside Length Gauge of the


diameter diameter needle to
introduce

PT1305 13G 2.17 50 mm 14G


PT13075 13G 2.17 75 mm 14G
PT13095 13G 2.17 95 mm 14G
PT13110 13G 2.17 110 mm 14G
PT13140 13G 2.17 140 mm 14G
PT1505 15G 1.70 50 mm 16G
PT15075 15G 1.70 75 mm 16G
PT15095 15G 1.70 95 mm 16G
PT15110 15G 1.70 110 mm 16G
PT15140 15G 1.70 140 mm 16G
PT1705 17G 1.32 50 mm 18G
PT17075 17G 1.32 75 mm 18G
PT17095 17G 1.32 95 mm 18G
PT17140 17G 1,32 140 mm 18G

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
14/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
FastCutM
Tru-cut needle for soft tissues biopsy to use
with automatic gun type Magnum® Bard®

Luer connection

FastCutM is a tru-cut disposable biopsy needle studied for use with Palium and also suita-
ble for use with Bard® Magnum® reusable gun.
The device, is equipped with:
- cannula made with AISI 304 steel
- “Menghini” sharpening that allows an atraumatic precise cutting of the tissue.
Centimeter markings and sliding stopper on the cannula surface to easily determinate the insertion
depth with the maximum safety for the patient.
The handle is provided with a Luer connection to allow the connection to the syringe for
aspiration.

Needle size with international colour code stamped on the spacer and on the primary packaging.
The stylet has
-a triple ultra-sharp tip to penetrate easily also into fibrous tissues.
-a 20mm specimen notch for the sample capture.
Code Gauge x Length Coaxial OD/ID Coaxial Code
needle length coaxial code item with
without coaxial
coaxial Magnum® is a Bard’s brand.
MG1210 12G X 100 mm 44mm 2.50/2.17 mm PT11044 MGC1210
MG1213 12G X 130 mm 74mm 2.50/2.17 mm PT11074 MGC1213
MG1215 12G X 150 mm 94mm 2.50/2.17 mm PT11094 MGC1215
MG1216 12G X 160 mm 104mm 2.50/2.17 mm PT11104 MGC1216
MG1220 12G X 200 mm 144mm 2.50/2.17 mm PT11144 MGC1220
MG1410 14G X 100 mm 48.5 mm 2.42/2.17 mm PT13048 MGC1410 Palium is a MDL’s brand.
MG1413 14G X 130 mm 78.5 mm 2.42/2.17 mm PT13078 MGC1413
MG1416 14G X 160 mm 108.5 mm 2.42/2.17 mm PT13108 MGC1416 Optional a coaxial cannula for
MG1420 14G X 200 mm 148.5 mm 2.42/2.17 mm PT13148 MGC1420 multiple procedures performing is in-
serted into the packaging (MGC code).
MG1610 16G X 100 mm 48 mm 1.93/1.70 mm PT15048 MGC1610
Surface echogenic marker
MG1613 16G X 130 mm 78 mm 1.93/1.70 mm PT15078 MGC1613
MG1615 16G X 150 mm 98 mm 1.93/1.70 mm PT15098 MGC1615 enhances the
MG1616 16G X 160 mm 108 mm 1.93/1.70 mm PT15108 MGC1616 ultrasound visibility. The set includes a
MG1620 16G X 200 mm 148 mm 1.93/1.70 mm PT15148 MGC1620 spacer with side entry to facilitate the
MG1810 18G X 100 mm 48 mm 1.52/1.32 mm PT17048 MGC1810 positioning of the needle into the auto-
matic system.
MG 1813 18G X 130 mm 78 mm 1.52/1.32 mm PT17078 MGC1813
It is suitable for stereotactic procedure.
MG1815 18G X 150 mm 98mm 1.52/1.32 mm PT17098 MGC1815
MG1816 18G X 160 mm 108 mm 1.52/1.32 mm PT17108 MGC1816
MG1820 18G X 200 mm 148 mm 1.52/1.32 mm PT17148 MGC1820
MG1825 18G X 250 mm 198 mm 1.52/1.32 mm PT17198 MGC1825
MG1830 18G X 300 mm 248 mm 1.52/1.32 mm PT17248 MGC1830
MG2010 20G X 100 mm 48 mm 1.13/0.95 mm PT19048 MGC2010
MG2013 20G X 130 mm 78 mm 1.13/0.95 mm PT19078 MGC2013
MG2016 20G X 160 mm 108 mm 1.13/0.95 mm PT19108 MGC2016
MG2020 20G X 200 mm 148 mm 1.13/0.95 mm PT19148 MGC2020

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
15/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
FastCutP
Tru-cut needle for soft tissues biopsy to use
with automatic gun type PRO_MAG 2.5TM

FastCutP (MGP) is a tru-cut disposable biopsy needle for Pro-Mag 2.5TM


The device, is equipped with
- cannula made with AISI 304 steel
- “Menghini” sharpening that allows an atraumatic precise cutting of the tissue.
Centimeter markings and sliding stopper on the cannula surface to easily determine the inser-
tion depth with the maximum safety for the patient.

Needle size with international colour code stamped on the spacer and on the primary
packaging.
The stylet has
-a triple ultra-sharp tip to penetrate easily also into fibrous tissues.
-a 20mm specimen notch for the sample capture.

Code Gauge X Length Coaxial OD/ID Code Code


without length coaxial coaxial item Pro-MagTM is an Angyotech brand.
coaxial with coa-
xial
MGP1410 14G X 100 mm 44.5 mm 2.42/2.17 mm PT13044 MGPC1410
Optional a coaxial cannula for
MGP1412 14G X 120 mm 64.5 mm 2.42/2.17 mm PT13064 MGPC1412
multiple procedures performing is in-
MGP1416 14G X 160 mm 104.5 mm 2.42/2.17 mm PT13104 MGPC1416 serted into the packaging (MGC code).
MGP1420 14G X 200 mm 144.5 mm 2.42/2.17 mm PT13144 MGPC1420
MGP1610 16G X 100 mm 44 mm 1.93/1.70 mm PT15044 MGPC1610
MGP1612 16G X 120 mm 64 mm 1.93/1.70 mm PT15064 MGPC1612
MGP1616 16G X 160 mm 104 mm 1.93/1.70 mm PT15104 MGPC1616
Echogenic marker on the can-
nula enhances the ultrasound visibility
MGP1620 16G X 200 mm 144 mm 1.93/1.70 mm PT15144 MGPC1620 during the biopsy procedure in echo-
MGP1810 18G X 100 mm 44 mm 1.52/1.32 mm PT17044 MGPC1810 grafy. The set includes a spacer with side
MGP1812 18G X 120 mm 64 mm 1.52/1.32 mm PT17064 MGPC1812 entry to facilitate the positioning of the
MGP1816 18G X 160 mm 104 mm 1.52/1.32 mm PT17104 MGPC1816 needle into the automatic system.
MGP1820 18G X 200 mm 144 mm 1.52/1.32 mm PT17144 MGPC1820 FastrCutP is suitable for stereotac-
MGP1825 18G X 250 mm 194 mm 1.52/1.32 mm PT17194 MGPC1825 tic procedure.
MGP1830 18G X 300 mm 244 mm 1.52/1.32 mm PT17244 MGPC1830
MGP2010 20G X 100 mm 44 mm 1.13/0.95 mm PT19044 MGPC2010
MGP2012 20G X 120 mm 64 mm 1.13/0.95 mm PT19064 MGPC2012
MGP2016 20G X 160 mm 104 mm 1.13/0.95 mm PT19104 MGPC2016
MGP2020 20G X 200 mm 144mm 1.13/0.95 mm PT19144 MGPC2020

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
16/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
Palium
Automatic reusable device for soft tissues biopsy

Palium is an automatic, reusable device equipped with


a sequential advancement system of cannula and stylet.

Designed to get an high


quality of the core specimen.
Ultra-sharp tips and polished surfaces for a better entry and exit. Use exclusively with
FastCutM,
MDL ‘s needle.
Powerful dual spring system for consistent
and excellent core samples. Rapid-fire action.
Small size and lightweight.
One hand activation to provide easy ac-
cess to the tissue sample.
Dual penetration depths for flexibility and
convenience (22mm or 15mm).

The samples can be taken with just one firing of the


button.
Can be easly armed with just one hand.
May be sterilized with conventional methods.

Features a side entry for FastCut needle spacer.


- Safety to avoid accidental firing.
- Trigger site on the rear. Sequential loading system that requires
- Security button. a slight activation force.
Advancement lengths: 15 - 22mm.

Code

PL

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
17/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
Themy
Automatic disposable device for soft tissues biopsy

Themy(R)(TY/TYS) is an automatic, disposable device equipped with a sequential


advancement system of cannula and stylet.
Themy is a lightweight device that offers a spring loaded action that allows an accurate and
easy
penetration inside fibrous or calcified lesions
The device, is equipped with a AISI 304 stainless steel cannula with a “Menghini” sharpening
that
allows an atraumatic precise cutting of the tissue.
The cannula is provided with centimeter markings to easy determine the depth of insertion for
the safety of the patient.

In each step of the procedure, the


Themy(R) is a very stable and ultralight automatic device. operator is able to know the charging
It can be provided in two versions with different lenght of notch: status of cannula and stylet.
10mm (TYS) or 20 mm (TY). Needle size, with international colour
code, is
stamped on the hub and on the primary packaging. The stylet has a
triple Themy(R) is provided with two firing
ultra-sharp tip to penetrate easily also into fibrous tissues. sequential trigger points, one in front and one at
Possibility to take the sample with only one firing of the bottom. the back allowing to the doctor different handling
positions.

Two firing modes One hand


• A mode: releases cannula and stylet free loading
in rapid sequence and captures
tissue sample simultaneously.

• D mode: releases stylet and allows the


user
to wait the required time before to release the
cannula by pushing the button till the point A.

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
18/26
SOFT TISSUE BIOPSY
Themy
Automatic disposable device for soft tissues biopsy

Length Size Size Size Size


14G 16G 18G 20G
100 mm TY1410 TY1610 TY1810 TY2010
120 mm TY1412 TY1612 TY1812 TY2012
160 mm TY1416 TY1616 TY1816 TY2016
200 mm TY1420 TY1620 TY1820 TY2020
20 mm
250 mm - - TY1825 -
300 mm - - TY1830 -

Themy(R) can be provided with a coaxial introducer needle that allow execution of multiple
procedures (code TYC )

Code with coaxial Single coaxial Coaxial cannula


included needle code length
TYC1410 PT13044 44 mm

TYC1412 PT13064 64 mm
TYC1416 PT13104 104 mm
TYC1420 PT13144 144 mm
TYC1610 PT15044 44 mm
TYC1612 PT15064 64 mm
TYC1616 PT15104 104 mm
TYC1620 PT15144 144 mm
TYC1810 PT17044 44 mm
TYC1812 PT17064 64 mm
TYC1816 PT17104 104 mm
TYC1820 PT17144 144 mm
TYC1825 PT17194 194 mm
TYC1830 PT17244 244 mm
TYC2010 PT19044 44 mm
TYC2012 PT19064 64 mm
TYC2016 PT19104 104 mm
TYC2020 PT19144 144 mm

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
19/26
CIM REV5 11/01/2014
SOFT TISSUE BIOPSY
CytoCut
Chiba needle fo cyto-histological aspiration, injection, anesthesia,
amniocentesis and chorionic Villus sampling

Standard Chiba
tip with primary angle
at 16°

CytoCut (PB) is a disposable needle for aspirated biopsy, with stainless steel cannula and triple
sharpening. It is used for micro-histological and cytological aspiration,
local anesthesia administration, injection of contrast media, amniotic fluids sampling,
alcholizations, exploratory punctures, sampling of chorionic Villus and lombar punctures.

- Cannula provided with centimeter markings, depth stopper and a Luer-lock fitting.

Internal echogenic marker enables a correct positioning of the needle


and its constant visualization under ultrasound guidance.
- Stylet hub is coloured according to the international colour
code for easy gauge size identification.

Use destination:
Micro-histological and cytological aspiration, local anesthesia administration, injection of
contrast media, alcholizations, exploratory punctures, sampling of chorionic Villus.

Gau- Outer Code Code Code Code Code Code Code Code
ge dia- length length length length length length length length
me- 50 mm 70 mm 100 mm 120 150 200 mm 250 mm 300 mm
ter mm mm

17 1.40 PB1705 PB1707 PB1710 PB1712 PB1715 PB1720 PB1725 PB1730


18 1.27 PB1805 PB1807 PB1810 PB1812 PB1815 PB1820 PB1825 PB1830
20 0.90 PB2005 PB2007 PB2010 PB2012 PB2015 PB2020 PB2025 PB2030
21 0.80 PB2105 PB2107 PB2110 PB2112 PB2115 PB2120 PB2125 PB2130
22 0.70 PB2205 PB2207 PB2210 PB2212 PB2215 PB2220 PB2225 PB2230
23 0.60 PB2305 PB2307 PB2310 PB2312 PB2315 PB2320
25 0.50 PB2505 PB2507 PB2510 PB2512 PB2515 PB2520

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
20/26
CIM REV5 11/01/2014
BREAST NODULE LOCALIZATION
MarkSlim
Non-repositionable needle for pre-operative localization of
mammary nodules, slimline

MarkSlim (PNS) is a needle provided with a non-repositionable stainless steel wire for pre-
operative localization of not palpable breast lesions.It is equipped with:
- AISI 304 steel cannula with Lancet tip to enable high penetration capacity avoiding
excessive deflection and maximize the precision of insertion
- transparent Luer cone with an insertion funnel for easy wire loading.
The reduced dimensions of “Slime line” needle cone, allows to get through the holes of the com-
pression plane of the mammography machine.

The wire is marked in two places indicating the hook position into the cannula; the first line indicates that the wire is
located in the proximity of the tip needle; the second one warns the complete leakage of the hook from the tip. The
needle allows dye injections and liquids aspirations.
Centimeter markings and sliding stopper on the cannula surface to easily determine the insertion depth.
The needle is provided with a special clamp to fix the protruding wire to the skin avoiding its movement.

The hook on the tip of the wire, is available in three different geometric
versions:

-single

-double

-“Z”

Hook Gauge Outer Code Code Code Code Code


diameter length length length length 120 length
50 mm 70 mm 100 mm mm 150 mm

single 18 G 1.20 PNS1805 PNS1807 PNS1810 PNS1812 PNS1815


single 20 G 0.90 PNS2005 PNS2007 PNS2010 PNS2012 PNS2015
single 21 G 0.80 PNS2105 PNS2107 PNS2110 PNS2112 PNS2115
double 18 G 1.20 PNSX1805 PNSX1807 PNSX1810 PNSX1812 PNSX1815
double 20 G 0.90 PNSX2005 PNSX2007 PNSX2010 PNSX2012 PNSX2015
Z 18 G 1.20 PNSZ1805 PNSZ1807 PNSZ1810 PNSZ1812 PNSZ1815
Z 20 G 0.90 PNSZ2005 PNSZ2007 PNSZ2010 PNSZ2012 PNSZ2015

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
21/26
CIM REV5 11/01/2014
BREAST NODULE LOCALIZATION
AutoMark
Semiautomatic non-repositionable needle for pre-operative
localization of mammary nodules

AutoMark (PNA) is a needle equipped with a not repositionable stainless steel wire for
pre-operative localization of not palpable breast lesions. It is provided with wire activation sy-
stem by pressing a button allowing the doctor to use only one hand leaving free the
second one to manipulate the ultrasound guidance or other devices.

AutoMark needle is equipped with:


- AISI 304 steel cannula with Lancet tip to enable high penetration capacity avoiding excessive
deflection and maximize the precision of insertion,
- transparent Luer cone with insertion funnel that allows an easy re-introduction of the wire.

Centimeter markings and sliding stopper on the cannula surface to easily determine the insertion depth.
The needle is provided with a special clamp to fix the protruding wire to the skin avoiding its movement.

The hook on the tip of the wire, is available in three different geometric versions:

-single

-double

-“Z”

Hook Gauge Outer dia- Code Code Code Code Code


meter length length length length length
50 mm 70 mm 100 mm 120 mm 150 mm
single 18 G 1.20 PNA1805 PNA1807 PNA1810 PNA1812 PNA1815
single 20 G 0.90 PNA2005 PNA2007 PNA2010 PNA2012 PNA2015
single 21 G 0.80 PNA2105 PNA2107 PNA2110 PNA2112 PNA2115
double 18 G 1.20 PNAX1805 PNAX1807 PNAX1810 PNAX1812 PNAX1815
double 20 G 0.90 PNAX2005 PNAX2007 PNAX2010 PNAX2012 PNAX2015
Z 18 G 1.20 PNAZ1805 PNAZ1807 PNAZ1810 PNAZ1812 PNAZ1815
Z 20 G 0.90 PNAZ2005 PNAZ2007 PNAZ2010 PNAZ2012 PNAZ2015

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
22/26
CIM REV5 11/01/2014
BREAST NODULE LOCALIZATION
RepoMarkK
Repositionable needle for pre-operative
localization of mammary nodules

RepoMarkK(PRk) is a repositionable needle for pre-operative localization of not palpable breast


lesions. It is equipped with:
- AISI 304 steel cannula with Lancet tip to enable high penetration capacity avoiding excessive de-
flection and maximize the precision of insertion,
- wire with single curve hook.
The needle allows dye injection and liquids aspiration. Centimeter markings and sliding stopper on the
cannula surface to easily determine the insertion depth with the maximum safety for the patient.

The wire may be easily retracted and repositionated


without loosing its efficiency thanks to the elastic memory of the tip. The operator has the possibility to repe-
at the operation whenever necessary.
The needle is provided with a special clamp to fix the protruding wire to the skin avoiding its move-
ment.
Feature a medical nitinol wire with single curve hook (Homer type).

Insert the needle into Press the positioner, check the correct When the right position is rea-
the breast and localize position. In case of error, draw back ched, push the button on the
the nodule the positioner and repeat the opera- handle and release the wire
tion

Leave the hook inserted into the


Draw back and remove the breast and fix it with the clamp
needle
Hook Gauge Outer Code Code Code Code Code Code
diameter length length length length length length
30 mm 50 mm 70 mm 100 mm 120 mm 150 mm
Single 20 G 0.90 mm PRk2003 PRk2005 PRk2007 PRk2010 PRk2012 PRk2015

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
23/26
CIM REV5 11/01/2014
BREAST NODULE LOCALIZATION
RepoMark
Repositionable needle for pre-operative
localization of mammary nodules

RepoMark (PR) is a repositionable needle for pre-operative localization of not palpable breast le-
sions.
It is equipped with:
- AISI 304 steel cannula with Lancet tip to enable high penetration capacity avoiding excessive
deflection
and maximize the precision of insertion,
- transparent Luer cone with an insertion funnel for easy wire loading.
- wire with single curve hook.

The needle allows dye injection and liquids aspiration.


Centimeter markings and sliding stopper on the cannula surface to easily determine the insertion depth.

The wire may be easily retracted and repo-


sitionated without loosing its efficiency
thanks to the elastic memory of the tip. The
operator has the possibility to repeat the ope-
ration whenever necessary.

The needle is provided with a special clamp to fix


the protruding wire to the skin avoiding its movement

Hook Gauge Outer Code Code Code Code Code Code


diameter length length length length length length
30 mm 50 mm 70 mm 100 mm 120 mm 150 mm
Single 20 G 0.90 mm PR2003 PR2005 PR2007 PR2010 PR2012 PR2015

M.D.L. Srl
Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email : uc@mdlsrl.com
web : www.mdlsrl.com
24/26
M.D.L. develops, manufactures and markets
innovative biopsy Needles ,
surgical needles and medical products prima-
rily
in the field of the
human tissues biopsy.

M.D.L. produces a wide range of


disposable and reusable needles ,
focusing on interventional, diagnostic,
therapeutics, surgical and
OEM products

25/26
M.D.L. Srl - Via Tavani 1/a – 23014 – Delebio (So) Italy
Tel +39 -0342 682130 Fax +39 0342 691316
email :uc@mdlsrl.com web :www.mdlsrl.com

26/26

You might also like