SULFUR ANALYZER BRIMSTONE

Product Description

941LS Liquid Sulfur Analyzer


Safety and environmental concerns require attention to the residual H2S present in Claus-produced
liquid sulfur product.
Whether or not sulfur degassing is used in a plant, it may be necessary to monitor the amount of
H2S/H2Sx contained in the liquid sulfur to ensure safe shipping, handling, and processing. In con-
junction with a major university, Brimstone has developed and now markets an analytical system
capable of this measurement. The Brimstone 941-LS Liquid Sulfur Analyzer is a laboratory-based
analytical system designed for direct measurement of dissolved H2S and H2Sx in liquid sulfur.
The measurement of H2S in liquid sulfur is complicated somewhat by the fact that it exists in two
distinct forms, H2S (dissolved gas) and H2Sx (dissolved polymer), which are in equilibrium with each
other and with elemental sulfur (S8). The use of state-of-the-art Fourier transform infrared (FT-IR)
spectrometry allows the resolution of both H2S and H2Sx absorptions giving accurate determina-
tions (±8% of the measured value) for total H2S with a range from 2 to 350 ppmw. Brimstone also
offers set-up and repair services on these systems along with spare parts and Performance Verifi-
cation (calibration check) ampoule kits. Because this analytical system is robust and relatively easy
to use, we also offer these units on a rental basis for short and medium term projects.

Our newly re-designed system features the newest analyzer from Thermo Scientific, theNicolet
iS5 FT-IR spectrometer. Based on the same analytical platform as the iS10, the iS5 has been rede-
signed as a smaller, lighter, and less expensive analyzer with all the functionality of its predecessor,
the iS10. The new Nicolet iS5 spectrometer has been tested by ASRL in their Calgary labs and found
to be as fully functional and accurate as the older iS10 model.

In addition to the spectrometer upgrade, our newly designed Brimstone sample cell and sulfur
sampling pot have been made smaller, lighter, and easier to use. Our new universal sample cell
features better temperature control and is small enough to fit in any of the spectrometers used for
this purpose. This new low voltage system is safer and simpler to operate. The new sulfur sample
pot is smaller and lighter than previous versions and stays warm much longer. Because it operates
on a low voltage system, it can be plugged into a vehicle lighter plug and kept warm during transit
to and from the lab while on extended sampling trips.

SULFUR ANALYZER BRIMSTONE


System Specifications:
Analysis time 2 minutes
Accuracy ±8% of total residual H2S
Calibration Range H2Sx = 150 ppmw, H2S = 200 ppmw, Total = 350 ppmw
Minimum Detection 2 ppmw