You are on page 1of 8

Product details of Contec CMS8000 Patient Monitor CMS8000 6-parameter

PRICE: 27,
 Standard parameters: ECG SPO2 NIBP RESP TEMP PR
 Optional parameters: 2-IBP CO2 thermal printer
 12'' color TFT LCD with high-resolution
 Multiple display modes are optional, such as big characters interface
 Built-in SD card, U disk for storing data and U disk updating
 Three operation modes: monitoring, surgery and diagnosis
Introduction:

Standard parameters: ECG SPO2 NIBP RESP TEMP PR


Optional parameters: 2-IBP CO2 thermal printer.
Features:

Display mode: 12'' color TFT LCD with high-resolution.


Be applicable for adult, pediatric and neonatal for all-round monitoring.
Operation interface with Chinese and English. (Optional languages: French, German, Italian, Turkish, etc.)
Multiple display modes are optional, such as big characters interface.
Waveform and data colour can be set optionally.
Storage of 480-hour trend data, and review of 40-second holographic waveform.
7-lead ECG displays in a screen, and ECG waveforms series display.
Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.
Function of NIBP review, storage for up to 400 NIBP data.
Connect central monitoring station, other bed observation and software updating with wireless and wired mode.
Built-in SD card, U disk for storing data and U disk updating.
Support the functions of VGA video output and adjustable LCD backlight.
Support alarm with human voice body.
Function of synchronous signal output.
Three operation modes: monitoring, surgery and diagnosis.
Auto-analysis for arrhythmia waveform.
Calculation function for drug concentration and titration table.
Dual-channel temperature monitoring, and with temperature error display.
NIBP dual-overpressure protection with software and hardware.
Built-in thermal printer.
Built-in rechargeable lithium battery for uninterrupted monitoring.
The product has passed FDA certification in America and CE certification in Europe.
Performance:

ECG
Lead Mode 3-lead and 5-lead are optional
Lead Selection I, II, III, avR, avL, avF, V
Gain Selection ×0.25, ×0.5, ×1, ×2
HR Range 15 ~ 300 bpm
Measuring and Alarm Range for ST Segment -0.6 mV~ + 0.8 mV
Scan Speed for ECG Waveform 12.5mm/s, 25mm/s, 50mm/s
RESP

Measuring Method R-F(RA-LL) Impedance


Measuring and Alarm Range for Resp. Rate:
Adult 0~120rpm
Pediatric and Neonatal 0~150rpm
Apnea Alarm 10 ~ 40 S
SpO2

Measuring Range 0 ~ 100 %


Accuracy
70% ~ 100% ±2%
0% ~ 69% unspecified
Measuring range for pulse rate 0~250bpm
SpO2 probe SpO2 probe for adult, pediatric and neonatal are optional
NIBP

Method Oscillometry
Mode Manual, Auto, Continuous
Measuring Period in Continuous Mode 5 Min
Measuring and Alarm Range 10~270mmHg
Overpressure protection dual-protection with software and hardware
Cuff cuff for adult, pediatric and neonatal are optional
TEMP
Channel dual-channel
Measuring and Alarm Range 0 ~ 50°C
Resolution 0.1°C
Accuracy ±0.1°C
u EtCO2(optional)
Method Sidestream or Mainstream
Measuring Range for CO2 0~150mmHg
Resolution for CO2:

0.1 mm Hg 0 to 69 mm Hg
0.25 mm Hg 70 to 150 mm Hg
Accuracy for CO2:

0 – 40 mm Hg ±2 mm Hg
41 – 70 mm Hg ±5%
71 – 100 mm Hg ±8%
101 – 150 mm Hg ±10%
Respiration Rate>80BPM ±12%
AwRR Range 2~150 rpm
AwRR Accuracy ±1BPM
Apnea Alarm Available
IBP(optional)
Channel dual-channel
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range -50~350 mm Hg
Resolution 1 mm Hg
Accuracy ±2% or 1mm Hg, which is greater
Recorder(optional)
Print Mode thermal array
Recording Width 48mm
Paper Speed 25mm/s, 50mm/s
Quantity of Printing Waveform dual-channel
Physical characteristic:

Requirement of power AC 100~240V, 50/60Hz


Power consumption 150VA
Dimension 310×140×263(mm)
Net weight 3.8Kg
Specifications of Contec CMS8000 Patient Monitor CMS8000 6-parameter
 Brand
CONTEC
 SKU
CO318HBAA3HOZEANPH-7293293
 Model
CONTEC MEDICAL-3.05.013.04.001
What’s in the box
 1 × CMS8000
 1 × Adult SPO1 Probe
 1 × Adult Cuff
 1 × NIBP Tube
 1 × 5 Leads ECG Cable
 1 × Electrodes(20pcs/pack)
 1 × TEMP probe
 1 × User Manual
 1 × Power Cable
 1 × Battery
Product details of Vinmax RPM-9000A 12-inch ICU CCU 6-parameter Patient

Monitor+thermal printer+ETCO2
 12" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical
parameters
 Unique digital SPO2 technology can work accurate during motion and low perfusion
 Anti AC &high-frequency electrosurgical &defibrillator’s interference
 Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
 Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
 ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
 Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
 Wired/wireless networking with central monitoring system, up to 64 beds in one group 
Features for Patient Monitor:    
Ergonomic design, portable, convenient for use;
Audible & visual alarm available, adjustable;
Patient information management function;
Super long life rechargeable Lithium battery upto 4 hours of working time;
Suitable for adult, pediatrics and neonate patients;
Optional software upgrading based on USB;
Built-in 3 trace thermal recorder for printing real-time and historical data;
 
Specification for Patient Monitor:
  
ECG:
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with
histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of
arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
ST section 
Scope:     ±0.8mV
Precision :  < ±0.05mV
SpO2
Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 
NIBP 
Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%
Resp:
Chest impedance method or concentration of carbon dioxide at end of respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute 
Temp:
Single/double path 
Type:    Vascular/surface temperature 
Scope:    20℃~50℃
Accuracy:  ±0.2℃
 
Invasive blood pressure (optional)
 
Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV
Specifications of Vinmax RPM-9000A 12-inch ICU CCU 6-parameter Patient Monitor+thermal printer+ETCO2
 Brand
vinmax
 SKU
264343174_PH-369715906
 Model
RPM-9000A 12-inch ICU CCU 6-parameter Patient Monitor+thermal printer+ETCO2
 Warranty Type
No Warranty
Product details of Portable 5 Inch TFT Multi-Parameter Patient Monitor ECG NIBP

SPO2 PR TEMP
 Touch screen,5.0 inch color TFT -LCD, simple for operating, quickly&accurately measure the data;
 Build -in rechargeable Li -battery, up to 15 hours running time, support AC and DC power;
 Adjustable audible and visual alarms, and sensor off alarm;
 Long time monitoring and sleeping monitoring;
 Easy to carry, suitable for ambulance center.

Description:

Features:
Touch screen,5.0 inch color TFT -LCD, simple for operating, quickly&accurately measure the data;
Build -in rechargeable Li -battery, up to 15 hours running time, support AC and DC power;
Adjustable audible and visual alarms, and sensor off alarm;
Long time monitoring and sleeping monitoring;
Easy to carry, suitable for ambulance center.
Prior:
Storage and review data up to 3888groups via Trend Graph and Trend List.
USB and Bluetooth data upload;
Big font screen interface is easy to observe;
Back light can be adjusted;
Free advanced software

Specifications of Portable 5 Inch TFT Multi-Parameter Patient Monitor ECG NIBP SPO2 PR TEMP
 Brand
carejoy (TM)
 SKU
CA156HBAA307IEANPH-6148014
 Model
Risingmed Technology-800180
 Warranty Type
No Warranty
What’s in the box
 1 x Portable 5 Inch TFT Multi-Parameter Patient Monitor ECG NIBP SPO2 PR TEMP

You might also like