FOX61x
SAMO1
User Manual
User Manual FOX61x
SAMO1
Disclaimer: ABB has taken reasonable care in compiling this document, however ABB accepts no liability
whatsoever for any error or omission in the information contained herein and gives no other
warranty or undertaking as to its accuracy.
ABB can accept no responsibility for damages, resulting from the use of the network
components or the associated operating software. In addition, we refer to the conditions of
use specified in the license contract.
ABB reserves the right to amend this document at any time without prior notice.
1 Preface 15
1.1 Precautions and safety 15
1.2 Symbols and notations 15
1.3 Interfaces and circuit categories 15
1.4 Document history 16
2 Introduction 17
2.1 General 17
2.2 Unit view 19
2.3 Block diagram 19
4 Installation 31
4.1 Prerequisites 31
4.2 Slots for the SAMO1 unit 31
4.3 SFP modules 32
4.3.1 SFP interface types 32
4.3.2 SFP module mounting 32
4.3.2.1 SFP module with bail actuator 33
4.3.2.2 SFP module with unlocking actuator 33
4.4 Compatibility 34
4.4.1 FOX units 34
4.4.2 Previous ESW revisions 34
4.5 Connections and cables 35
4.5.1 Front connectors of the SAMO1 unit 35
4.5.2 Optical SDH interface cables 37
4.5.3 Electrical SDH interface cable, DIN to open end 38
4.5.4 Electrical SDH interface cable, DIN to BNC 38
4.5.5 Ethernet interface cables 39
4.5.6 Fixing the cables to the cable tray 39
FOX61xSAMO1 1
5 Functional Description 41
5.1 Applications 41
5.1.1 SDH terminal multiplexer unprotected 42
5.1.2 SDH terminal multiplexer with MSP protection 43
5.1.3 Ethernet over an SDH terminal multiplexer 43
5.1.4 SDH add/drop multiplexer 45
5.1.5 SDH add/drop multiplexer with MSP protection 46
5.1.6 SDH add/drop multiplexer with equipment protection 47
5.1.7 Ethernet over an SDH add/drop multiplexer 48
5.1.8 Point to point Ethernet over SDH 50
5.2 SDH multiplexing 51
5.2.1 SDH multiplexing in ITU-T and ETSI standards 51
5.2.2 SDH multiplexing in FOX 51
5.3 SDH layers and functions 53
5.3.1 PS layer 53
5.3.2 RS layer 53
5.3.3 MS layer 54
5.3.4 AU-4 cross connect 55
5.3.5 VC-4 layer 56
5.3.6 TU-3 and TU-12 cross connect 57
5.3.7 VC-3 layer 57
5.3.8 VC-12 layer 58
5.4 PDH layers and functions 59
5.4.1 P12 layer 59
5.5 EoS layers and functions 60
5.5.1 Ethernet front interface 60
5.5.1.1 LAN mode 60
5.5.1.2 IEEE 802.3 flow control 61
5.5.1.3 Link pass through 61
5.5.2 Ethernet internal interfaces 62
5.5.2.1 Internal ports with optional CESM1 redundancy 62
5.5.2.2 Internal ports with two CESM1 units and one SAMO1 unit 64
5.5.2.3 Internal ports with two CESM1 units and two SAMO1 units 64
5.5.3 Ethernet over SDH (EoS) 65
5.5.3.1 Generic framing procedure (GFP) 65
5.5.3.2 Virtual concatenation (VCAT) 67
5.5.3.3 Link capacity adjustment scheme (LCAS) 69
5.6 Embedded communication channel (ECC) 70
5.7 Synchronisation and timing functions 71
5.8 Protection 72
5.8.1 Multiplex section protection (MSP) 72
5.8.2 Subnetwork connection protection SNCP/N 75
5.8.2.1 SNCP/N for VC-4 77
5.8.2.2 SNCP/N for VC-3 and VC-12 78
5.8.3 Subnetwork connection protection SNCP/I 79
5.8.3.1 SNCP/I for VC-4 80
5.8.3.2 SNCP/I for VC-3 and VC-12 81
5.8.4 P12 and P0-nc subnetwork connection protection SNCP 82
5.8.4.1 Protection from tributary side 82
2 FOX61xSAMO1
5.8.4.2 Protection from network side 84
5.8.5 Ethernet protection 84
5.8.6 Equipment protection (EQP) 85
5.8.6.1 EQP features 85
5.8.6.2 EQP prerequisites 87
5.8.6.3 EQP configuration 88
5.8.6.4 EQP status 89
6 Commissioning 91
6.1 Cross connections 91
6.1.1 VC-4 cross connections 94
6.1.2 VC-3 cross connections 96
6.1.3 VC-12 cross connections 98
6.1.4 P12 cross connections 101
6.1.5 P0-nc cross connections 102
6.1.6 Cross connection examples 104
6.2 SNCP configuration 106
6.2.1 SNCP timer configuration 106
6.2.2 SNCP degraded signal configuration 107
6.3 Resource usage strategy 107
6.4 Automatic laser shutdown and restart 108
6.4.1 Automatic laser shutdown 108
6.4.2 Automatic laser restart 109
6.5 Commissioning example of PDH and EoS transport 110
6.5.1 Prerequisites 110
6.5.1.1 CESM1 unit 110
6.5.1.2 SAMO1 unit 110
6.5.1.3 FOXCST 111
6.5.2 Configuration of the SDH multiplexer 111
7 Operation 125
7.1 Unit optical indicators 125
7.2 Loops 126
7.2.1 VC loops 126
7.2.2 P12 and P0-nc loops 127
7.3 Detection of signal defects 128
7.4 Trail trace identifier (TTI) 129
7.5 Maintenance 130
7.5.1 Inventory data 130
7.5.2 Unit ESW download 131
7.5.3 ESW upgrade with EQP 131
FOX61xSAMO1 3
8.2.3.2 AP: / unit-x, Configuration - General - Degraded Signal 140
8.2.3.3 AP: / unit-x, Configuration - General - EoS Resource Usage 141
8.2.3.4 AP: / unit-x, Configuration - SETS 142
8.2.3.5 AP: / unit-x, Configuration - ESO 144
8.2.3.6 AP: / unit-x, Configuration - EQP 147
8.2.4 AP: / unit-x, Fault Management 148
8.2.5 AP: / unit-x, Performance Management 151
8.2.5.1 AP: / unit-x, Performance Management - Unfiltered Events 151
8.2.6 AP: / unit-x, Status 152
8.2.6.1 AP: / unit-x, Status - SETS - General 152
8.2.6.2 AP: / unit-x, Status - SETS - Sources 154
8.2.6.3 AP: / unit-x, Status - ESO - General 156
8.2.6.4 AP: / unit-x, Status - ESO - Sources 158
8.2.6.5 AP: / unit-x, Status - EQP 159
8.3 AP: / unit-x / pdh 161
8.3.1 AP: / unit-x / pdh, Overview 161
8.3.2 AP: / unit-x / pdh, Main 161
8.4 AP: / unit-x / pdh / vc12-y 161
8.4.1 AP: / unit-x / pdh / vc12-y, Overview 161
8.4.2 AP: / unit-x / pdh / vc12-y, Main 161
8.4.2.1 AP: / unit-x / pdh / vc12-y, Main - General 161
8.4.2.2 AP: / unit-x / pdh / vc12-y, Main - Admin And Oper Status 162
8.4.3 AP: / unit-x / pdh / vc12-y, Configuration 162
8.4.3.1 AP: / unit-x / pdh / vc12-y, Configuration - General 162
8.4.3.2 AP: / unit-x / pdh / vc12-y, Configuration - CTP 164
8.4.4 AP: / unit-x / pdh / vc12-y, Fault Management 165
8.4.5 AP: / unit-x / pdh / vc12-y, Performance Management 167
8.4.5.1 AP: / unit-x / pdh / vc12-y, Performance Management - G.826 168
8.4.5.2 AP: / unit-x / pdh / vc12-y, Performance Management - Unfiltered Events 168
8.4.6 AP: / unit-x / pdh / vc12-y, Status 168
8.4.6.1 AP: / unit-x / pdh / vc12-y, Status - General 168
8.4.6.2 AP: / unit-x / pdh / vc12-y, Status - CTP 170
8.5 AP: / unit-x / pdh / vc12-y / p12 171
8.5.1 AP: / unit-x / pdh / vc12-y / p12, Overview 171
8.5.2 AP: / unit-x / pdh / vc12-y / p12, Main 171
8.5.2.1 AP: / unit-x / pdh / vc12-y / p12, Main - General 171
8.5.2.2 AP: / unit-x / pdh / vc12-y / p12, Main - Admin And Oper Status 172
8.5.3 AP: / unit-x / pdh / vc12-y / p12, Configuration 172
8.5.3.1 AP: / unit-x / pdh / vc12-y / p12, Configuration - General 172
8.5.3.2 AP: / unit-x / pdh / vc12-y / p12, Configuration - Synchronization 174
8.5.3.3 AP: / unit-x / pdh / vc12-y / p12, Configuration - Channels 175
8.5.4 AP: / unit-x / pdh / vc12-y / p12, Fault Management 177
8.5.5 AP: / unit-x / pdh / vc12-y / p12, Performance Management 178
8.5.5.1 AP: / unit-x / pdh / vc12-y / p12, Performance Management - G.826 179
8.5.5.2 AP: / unit-x / pdh / vc12-y / p12, Performance Management - P12 Events 179
8.5.6 AP: / unit-x / pdh / vc12-y / p12, Status 180
8.5.6.1 AP: / unit-x / pdh / vc12-y / p12, Status - Maintenance 180
8.5.6.2 AP: / unit-x / pdh / vc12-y / p12, Status - QL 181
4 FOX61xSAMO1
8.6 AP: / unit-x / pdh / vc12-y / p12 / chan-z 181
8.6.1 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Overview 181
8.6.2 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Main 181
8.6.2.1 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Main - General 181
8.6.2.2 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Main - Admin And Oper Status 182
8.6.3 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Configuration 182
8.6.3.1 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Configuration - CTP 182
8.6.4 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Fault Management 184
8.6.5 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Performance Management 184
8.6.5.1 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Performance Management - Protection 185
8.6.6 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status 185
8.6.6.1 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status - Maintenance 185
8.6.6.2 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status - CTP 186
8.7 AP: / unit-x / port-y, y = 1 … 4 187
8.7.1 AP: / unit-x / port-y, Overview 187
8.7.2 AP: / unit-x / port-y, Main 187
8.7.2.1 AP: / unit-x / port-y, Main - General 187
8.7.2.2 AP: / unit-x / port-y, Main - Admin And Oper Status 188
8.7.2.3 AP: / unit-x / port-y, Main - SFP 188
8.7.3 AP: / unit-x / port-y, Configuration 189
8.7.3.1 AP: / unit-x / port-y, Configuration - PS 189
8.7.3.2 AP: / unit-x / port-y, Configuration - RS 190
8.7.3.3 AP: / unit-x / port-y, Configuration - MS 192
8.7.3.4 AP: / unit-x / port-y, Configuration - MSP 194
8.7.3.5 AP: / unit-x / port-y, Configuration - DCC 194
8.7.4 AP: / unit-x / port-y, Fault Management 195
8.7.5 AP: / unit-x / port-y, Performance Management 197
8.7.5.1 AP: / unit-x / port-y, Performance Management - Unfiltered Events 197
8.7.5.2 AP: / unit-x / port-y, Performance Management - G.826 197
8.7.6 AP: / unit-x / port-y, Status 198
8.7.6.1 AP: / unit-x / port-y, Status - PS - ALS 198
8.7.6.2 AP: / unit-x / port-y, Status - PS - DDM 199
8.7.6.3 AP: / unit-x / port-y, Status - RS 199
8.7.6.4 AP: / unit-x / port-y, Status - MS 200
8.7.6.5 AP: / unit-x / port-y, Status - MSP 200
8.8 AP: / unit-x / port-y, y = 5 … 8 204
8.8.1 AP: / unit-x / port-y, Overview 204
8.8.2 AP: / unit-x / port-y, Main 204
8.8.2.1 AP: / unit-x / port-y, Main - General 204
8.8.2.2 AP: / unit-x / port-y, Main - Admin And Oper Status 204
8.8.3 AP: / unit-x / port-y, Configuration 205
8.8.3.1 AP: / unit-x / port-y, Configuration - EoS 205
8.8.3.2 AP: / unit-x / port-y, Configuration - PHY 206
8.8.4 AP: / unit-x / port-y, Fault Management 207
8.8.5 AP: / unit-x / port-y, Performance Management 207
8.8.5.1 AP: / unit-x / port-y, Performance Management - MIB-2 Interface Table 208
8.8.6 AP: / unit-x / port-y, Status 208
8.8.6.1 AP: / unit-x / port-y, Status - PHY 208
8.9 AP: / unit-x / port-y / dcc, y = 1 … 4 209
8.9.1 AP: / unit-x / port-y / dcc, Overview 209
8.9.2 AP: / unit-x / port-y / dcc, Main 209
FOX61xSAMO1 5
8.9.2.1 AP: / unit-x / port-y / dcc, Main - General 209
8.9.2.2 AP: / unit-x / port-y / dcc, Main - Admin And Oper Status 209
8.9.3 AP: / unit-x / port-y / dcc, Configuration 210
8.9.3.1 AP: / unit-x / port-y / dcc, Configuration - CTP 210
8.9.4 AP: / unit-x / port-y / dcc, Fault Management 211
8.9.5 AP: / unit-x / port-y / dcc, Performance Management 212
8.9.5.1 AP: / unit-x / port-y / dcc, Performance Management - MIB-2 Interface Table 212
8.9.6 AP: / unit-x / port-y / dcc, Status 212
8.9.6.1 AP: / unit-x / port-y / dcc, Status - General 212
8.9.6.2 AP: / unit-x / port-y / dcc, Status - CTP 213
8.10 AP: / unit-x / port-y / j-z, y = 1 … 4 214
8.10.1 AP: / unit-x / port-y / j-z, Overview 214
8.10.2 AP: / unit-x / port-y / j-z, Main 214
8.10.2.1 AP: / unit-x / port-y / j-z, Main - General 214
8.10.2.2 AP: / unit-x / port-y / j-z, Main - Admin And Oper Status 215
8.10.3 AP: / unit-x / port-y / j-z, Configuration 215
8.10.3.1 AP: / unit-x / port-y / j-z, Configuration - CTP 215
8.10.4 AP: / unit-x / port-y / j-z, Fault Management 216
8.10.5 AP: / unit-x / port-y / j-z, Status 217
8.10.5.1 AP: / unit-x / port-y / j-z, Status - CTP 217
8.11 AP: / unit-x / port-y / eos, y = 5… 8 218
8.11.1 AP: / unit-x / port-y / eos, Overview 218
8.11.2 AP: / unit-x / port-y / eos, Main 218
8.11.2.1 AP: / unit-x / port-y / eos, Main - General 218
8.11.2.2 AP: / unit-x / port-y / eos, Main - Admin And Oper Status 219
8.11.3 AP: / unit-x / port-y / eos, Configuration 219
8.11.3.1 AP: / unit-x / port-y / eos, Configuration - General 219
8.11.4 AP: / unit-x / port-y / eos, Fault Management 220
8.11.5 AP: / unit-x / port-y / eos, Performance Management 222
8.11.5.1 AP: / unit-x / port-y / eos, Performance Management - EoS GFP Encapsulation 222
8.11.6 AP: / unit-x / port-y / eos, Status 223
8.11.6.1 AP: / unit-x / port-y / eos, Status - General 223
8.12 AP: / unit-x / port-y / eos / vcz-a 223
8.12.1 AP: / unit-x / port-y / eos / vcz-a, Overview 223
8.12.2 AP: / unit-x / port-y / eos / vcz-a, Main 223
8.12.2.1 AP: / unit-x / port-y / eos / vcz-a, Main - General 223
8.12.2.2 AP: / unit-x / port-y / eos / vcz-a, Main - Admin And Oper Status 224
8.12.3 AP: / unit-x / port-y / eos / vcz-a, Configuration 224
8.12.3.1 AP: / unit-x / port-y / eos / vcz-a, Configuration - CTP 224
8.12.4 AP: / unit-x / port-y / eos / vc4-a, Fault Management 226
8.12.5 AP: / unit-x / port-y / eos / vc3-a, Fault Management 227
8.12.6 AP: / unit-x / port-y / eos / vc12-a, Fault Management 228
8.12.7 AP: / unit-x / port-y / eos / vcz-a, Performance Management 230
8.12.7.1 AP: / unit-x / port-y / eos / vcz-a, Performance Management - G.826 230
8.12.7.2 AP: / unit-x / port-y / eos / vcz-a, Performance Management - Unfiltered Events 231
8.12.8 AP: / unit-x / port-y / eos / vcz-a, Status 231
8.12.8.1 AP: / unit-x / port-y / eos / vcz-a, Status - General 231
8.12.8.2 AP: / unit-x / port-y / eos / vcz-a, Status - EoS 232
8.12.8.3 AP: / unit-x / port-y / eos / vcz-a, Status - CTP 233
8.13 AP: / unit-x / vc4 235
8.13.1 AP: / unit-x / vc4, Overview 235
6 FOX61xSAMO1
8.13.1.1 AP: / unit-x / vc4, Overview - VC4 Overview 235
8.13.2 AP: / unit-x / vc4, Main 235
8.13.3 AP: / unit-x / vc4, Configuration 236
8.13.3.1 AP: / unit-x / vc4, Configuration - General 236
8.14 AP: / unit-x / vc4 / vc4-b 237
8.14.1 AP: / unit-x / vc4 / vc4-b, Overview 237
8.14.2 AP: / unit-x / vc4 / vc4-b, Main 237
8.14.2.1 AP: / unit-x / vc4 / vc4-b, Main - General 237
8.14.2.2 AP: / unit-x / vc4 / vc4-b, Main - Admin And Oper Status 237
8.14.3 AP: / unit-x / vc4 / vc4-b, Configuration 238
8.14.3.1 AP: / unit-x / vc4 / vc4-b, Configuration - General 238
8.14.3.2 AP: / unit-x / vc4 / vc4-b, Configuration - TUG-3 Structure 238
8.14.3.3 AP: / unit-x / vc4 / vc4-b, Configuration - CTP 239
8.14.4 AP: / unit-x / vc4 / vc4-b, Fault Management 240
8.14.5 AP: / unit-x / vc4 / vc4-b, Performance Management 242
8.14.5.1 AP: / unit-x / vc4 / vc4-b, Performance Management - G.826 243
8.14.5.2 AP: / unit-x / vc4 / vc4-b, Performance Management - Unfiltered Events 243
8.14.6 AP: / unit-x / vc4 / vc4-b, Status 243
8.14.6.1 AP: / unit-x / vc4 / vc4-b, Status - General 243
8.14.6.2 AP: / unit-x / vc4 / vc4-b, Status - CTP 245
8.15 AP: / unit-x / vc4 / vc4-b / klm-n00 246
8.15.1 AP: / unit-x / vc4 / vc4-b / klm-n00, Overview 246
8.15.2 AP: / unit-x / vc4 / vc4-b / klm-n00, Main 246
8.15.2.1 AP: / unit-x / vc4 / vc4-b / klm-n00, Main - General 246
8.15.2.2 AP: / unit-x / vc4 / vc4-b / klm-n00, Main - Admin And Oper Status 246
8.15.3 AP: / unit-x / vc4 / vc4-b / klm-n00, Configuration 247
8.15.3.1 AP: / unit-x / vc4 / vc4-b / klm-n00, Configuration - CTP 247
8.15.4 AP: / unit-x / vc4 / vc4-b / klm-n00, Fault Management 248
8.15.5 AP: / unit-x / vc4 / vc4-b / klm-n00, Status 249
8.15.5.1 AP: / unit-x / vc4 / vc4-b / klm-n00, Status - CTP 249
8.16 AP: / unit-x / vc4 / vc4-b / klm-npq 250
8.16.1 AP: / unit-x / vc4 / vc4-b / klm-npq, Overview 250
8.16.2 AP: / unit-x / vc4 / vc4-b / klm-npq, Main 250
8.16.2.1 AP: / unit-x / vc4 / vc4-b / klm-npq, Main - General 250
8.16.2.2 AP: / unit-x / vc4 / vc4-b / klm-npq, Main - Admin And Oper Status 250
8.16.3 AP: / unit-x / vc4 / vc4-b / klm-npq, Configuration 251
8.16.3.1 AP: / unit-x / vc4 / vc4-b / klm-npq, Configuration - CTP 251
8.16.4 AP: / unit-x / vc4 / vc4-b / klm-npq, Fault Management 252
8.16.5 AP: / unit-x / vc4 / vc4-b / klm-npq, Status 253
8.16.5.1 AP: / unit-x / vc4 / vc4-b / klm-npq, Status - CTP 253
8.17 AP: / unit-x / internalPorts 254
8.17.1 AP: / unit-x / internalPorts, Overview 254
8.17.2 AP: / unit-x / internalPorts, Main 254
8.17.2.1 AP: / unit-x / internalPorts, Main - General 254
8.18 AP: / unit-x / internalPorts / port-y 254
8.18.1 AP: / unit-x / internalPorts / port-y, Overview 254
8.18.2 AP: / unit-x / internalPorts / port-y, Main 255
8.18.2.1 AP: / unit-x / internalPorts / port-y, Main - General 255
8.18.2.2 AP: / unit-x / internalPorts / port-y, Main - Admin And Oper Status 255
8.18.3 AP: / unit-x / internalPorts / port-y, Configuration 256
8.18.3.1 AP: / unit-x / internalPorts / port-y, Configuration - EoS 256
FOX61xSAMO1 7
8.18.3.2 AP: / unit-x / internalPorts / port-y, Configuration - PHY 256
8.18.4 AP: / unit-x / internalPorts / port-y, Performance Management 257
8.18.4.1 AP: / unit-x / internalPorts / port-y, Performance Management - MIB-2 Interface Table 257
8.18.5 AP: / unit-x / internalPorts / port-y, Status 258
8.18.5.1 AP: / unit-x / internalPorts / port-y, Status - PHY 258
8.19 AP: / unit-x / internalPorts / port-y / eos 258
8.19.1 AP: / unit-x / internalPorts / port-y / eos, Overview 258
8.19.2 AP: / unit-x / internalPorts / port-y / eos, Main 259
8.19.2.1 AP: / unit-x / internalPorts / port-y / eos, Main - General 259
8.19.2.2 AP: / unit-x / internalPorts / port-y / eos, Main - Admin And Oper Status 259
8.19.3 AP: / unit-x / internalPorts / port-y / eos, Configuration 259
8.19.3.1 AP: / unit-x / internalPorts / port-y / eos, Configuration - General 259
8.19.4 AP: / unit-x / internalPorts / port-y / eos, Fault Management 261
8.19.5 AP: / unit-x / internalPorts / port-y / eos, Performance Management 262
8.19.5.1 AP: / unit-x / internalPorts / port-y / eos, Perf. Management - EoS GFP Encapsulation 262
8.19.6 AP: / unit-x / internalPorts / port-y / eos, Status 263
8.19.6.1 AP: / unit-x / internalPorts / port-y / eos, Status - General 263
8.20 AP: / unit-x / internalPorts / port-y / eos / vcx-a 263
8.20.1 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Overview 263
8.20.2 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Main 263
8.20.2.1 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Main - General 263
8.20.2.2 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Main - Admin And Oper Status 264
8.20.3 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Configuration 264
8.20.3.1 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Configuration - CTP 264
8.20.4 AP: / unit-x / internalPorts / port-y / eos / vc4-a, Fault Management 266
8.20.5 AP: / unit-x / internalPorts / port-y / eos / vc3-a, Fault Management 267
8.20.6 AP: / unit-x / internalPorts / port-y / eos / vc12-a, Fault Management 268
8.20.7 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Performance Management 270
8.20.7.1 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Performance Management - G.826 270
8.20.7.2 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Perf. Management - Unfiltered Events 270
8.20.8 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Status 271
8.20.8.1 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Status - General 271
8.20.8.2 AP: / unit-x / internalPorts / port-y / eos / vcz-a, Status - EoS 272
8.20.8.3 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Status - CTP 273
9 Annex 275
9.1 Associated FOX documents 275
8 FOX61xSAMO1
Figures
FOX61xSAMO1 9
Figure 45: VC-3 SNCP/I example 81
Figure 46: P12 SNCP/I from the tributary side 83
Figure 47: P12 SNCP/I from the network side with two SAMO1 units 84
Figure 48: Ethernet protection using an Ethernet switch 85
Figure 49: Equipment protection for PDH traffic 86
Figure 50: Equipment protection for Ethernet traffic (VC-4 EoS) 87
Figure 51: Cross connection overview 92
Figure 52: Cross connection detail overview 93
Figure 53: Cross connections in the VC-4 layer 95
Figure 54: Cross connections in the VC-3 layer 97
Figure 55: Cross connections in the VC-12 layer 99
Figure 56: Cross connections in the P12 layer 101
Figure 57: Cross connections in the P0-nc layer 103
Figure 58: Holdoff and guard times 106
Figure 59: Automatic laser shutdown (ALS) 109
Figure 60: Automatic laser restart (ALR) 110
Figure 61: SAMO1 configuration example 112
Figure 62: Fault indication LEDs on the SAMO1 unit 125
Figure 63: Loops with unidirectional cross connections 126
Figure 64: Location of “front to front” and “back to back” loops 127
Figure 65: TTI application 130
Figure 66: MOM (managed object model) of the SAMO1 unit 136
10 FOX61xSAMO1
Tables
FOX61xSAMO1 11
Table 45: AP: / unit-x, Configuration - EQP 148
Table 46: AP: / unit-x, Fault Management 148
Table 47: PM counter interval availability 151
Table 48: PM group: Unfiltered Events 151
Table 49: AP: / unit-x, Status - SETS - General 152
Table 50: AP: / unit-x, Status - SETS - Sources 154
Table 51: AP: / unit-x, Status - ESO - General 156
Table 52: AP: / unit-x, Status - ESO - Sources 158
Table 53: AP: / unit-x, Status - EQP 160
Table 54: AP: / unit-x / pdh / vc12-y, Main - Admin And Oper Status 162
Table 55: AP: / unit-x / pdh / vc12-y, Configuration - General 163
Table 56: AP: / unit-x / pdh / vc12-y, Configuration - CTP 164
Table 57: AP: / unit-x / pdh / vc12-y, Fault Management 165
Table 58: PM counter interval availability 167
Table 59: PM group: G.826 VC-12 168
Table 60: PM group: Unfiltered Events 168
Table 61: AP: / unit-x / pdh / vc12-y, Status - General 169
Table 62: AP: / unit-x / pdh / vc12-y, Status - CTP 170
Table 63: AP: / unit-x / pdh / vc12-y / p12, Main - Admin And Oper Status 172
Table 64: AP: / unit-x / pdh / vc12-y / p12, Configuration - General 173
Table 65: AP: / unit-x / pdh / vc12-y / p12, Configuration - Synchronization 174
Table 66: AP: / unit-x / pdh / vc12-y / p12, Configuration - Channels 175
Table 67: AP: / unit-x / pdh / vc12-y / p12, Fault Management 177
Table 68: PM counter interval availability 179
Table 69: PM group: G.826 179
Table 70: PM group: P12 Events 179
Table 71: AP: / unit-x / pdh / vc12-y / p12, Status - Maintenance 180
Table 72: AP: / unit-x / pdh / vc12-y / p12, Status - QL 181
Table 73: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Main - Admin And Oper Status 182
Table 74: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Configuration - CTP 183
Table 75: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Fault Management 184
Table 76: PM counter interval availability 185
Table 77: PM group: Protection 185
Table 78: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status - Maintenance 185
Table 79: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status - CTP 186
Table 80: AP: / unit-x / port-y, Main - Admin And Oper Status 188
Table 81: AP: / unit-x / port-y, Main - SFP 189
Table 82: AP: / unit-x / port-y, Configuration - PS 190
Table 83: AP: / unit-x / port-y, Configuration - RS 191
Table 84: AP: / unit-x / port-y, Configuration - MS 193
Table 85: AP: / unit-x / port-y, Configuration - MSP 194
Table 86: AP: / unit-x / port-y, Configuration - DCC 195
Table 87: AP: / unit-x / port-y, Fault Management 195
Table 88: PM counter interval availability 197
Table 89: PM group: Unfiltered Events 197
Table 90: PM group: G.826 197
Table 91: AP: / unit-x / port-y, Status - PS - ALS 198
Table 92: AP: / unit-x / port-y, Status - PS - DDM 199
12 FOX61xSAMO1
Table 93: AP: / unit-x / port-y, Status - RS 200
Table 94: AP: / unit-x / port-y, Status - MS 200
Table 95: AP: / unit-x / port-y, Status - MSP 201
Table 96: AP: / unit-x / port-y, Main - Admin And Oper Status 204
Table 97: AP: / unit-x / port-y, Configuration - EoS 205
Table 98: AP: / unit-x / port-y, Configuration - PHY 206
Table 99: AP: / unit-x / port-y, Fault Management 207
Table 100: PM counter interval availability 207
Table 101: PM group: MIB-2 Interface Table 208
Table 102: AP: / unit-x / port-y, Status - PHY 208
Table 103: AP: / unit-x / port-y / dcc, Main - Admin And Oper Status 210
Table 104: AP: / unit-x / port-y / dcc, Configuration - CTP 210
Table 105: AP: / unit-x / port-y / dcc, Fault Management 211
Table 106: PM counter interval availability 212
Table 107: PM group: MIB-2 Interface Table 212
Table 108: AP: / unit-x / port-y / dcc, Status - General 213
Table 109: AP: / unit-x / port-y / dcc, Status - CTP 213
Table 110: AP: / unit-x / port-y / j-z, Main - Admin And Oper Status 215
Table 111: AP: / unit-x / port-y / j-z, Configuration - CTP 216
Table 112: AP: / unit-x / port-y / j-z, Fault Management 217
Table 113: AP: / unit-x / port-y / j-z, Status - CTP 217
Table 114: AP: / unit-x / port-y / eos, Main - Admin And Oper Status 219
Table 115: AP: / unit-x / port-y / eos, Configuration - General 219
Table 116: AP: / unit-x / port-y / eos, Fault Management 221
Table 117: PM counter interval availability 222
Table 118: PM group: EoS GFP Encapsulation 222
Table 119: AP: / unit-x / port-y / eos, Status - General 223
Table 120: AP: / unit-x / port-y / eos / vcz-a, Main - Admin And Oper Status 224
Table 121: AP: / unit-x / port-y / eos / vcz-a, Configuration - CTP 225
Table 122: AP: / unit-x / port-y / eos / vc4-a, Fault Management 226
Table 123: AP: / unit-x / port-y / eos / vc3-a, Fault Management 227
Table 124: AP: / unit-x / port-y / eos / vc12-a, Fault Management 229
Table 125: PM counter interval availability 230
Table 126: PM group: G.826 230
Table 127: PM group: Unfiltered Events 231
Table 128: AP: / unit-x / port-y / eos / vcz-a, Status - General 231
Table 129: AP: / unit-x / port-y / eos / vcz-a, Status - EoS 233
Table 130: AP: / unit-x / port-y / eos / vcz-a, Status - CTP 234
Table 131: AP: / unit-x / vc4, Overview - VC4 Overview 235
Table 132: AP: / unit-x / vc4, Configuration - General 236
Table 133: AP: / unit-x / port-y, Main - Admin And Oper Status 237
Table 134: AP: / unit-x / vc4 / vc4-b, Configuration - General 238
Table 135: AP: / unit-x / vc4 / vc4-b, Configuration - TUG-3 Structure 239
Table 136: AP: / unit-x / vc4 / vc4-b, Configuration - CTP 239
Table 137: AP: / unit-x / vc4 / vc4-b, Fault Management 240
Table 138: PM counter interval availability 242
Table 139: PM group: G.826 243
Table 140: PM group: Unfiltered Events 243
FOX61xSAMO1 13
Table 141: AP: / unit-x / vc4 / vc4-b, Status - General 244
Table 142: AP: / unit-x / vc4 / vc4-b, Status - CTP 245
Table 143: AP: / unit-x / vc4 / vc4-b / klm-n00, Main - Admin And Oper Status 247
Table 144: AP: / unit-x / vc4 / vc4-b / klm-n00, Configuration - CTP 247
Table 145: AP: / unit-x / vc4 / vc4-b / klm-n00, Fault Management 248
Table 146: AP: / unit-x / vc4 / vc4-b / klm-n00, Status - CTP 249
Table 147: AP: / unit-x / vc4 / vc4-b / klm-npq, Main - Admin And Oper Status 251
Table 148: AP: / unit-x / vc4 / vc4-b / klm-npq, Configuration - CTP 251
Table 149: AP: / unit-x / vc4 / vc4-b / klm-npq, Fault Management 252
Table 150: AP: / unit-x / vc4 / vc4-b / klm-npq, Status - CTP 253
Table 151: AP: / unit-x / internalPorts / port-y, Main - Admin And Oper Status 255
Table 152: AP: / unit-x / internalPorts / port-y, Configuration - EoS 256
Table 153: AP: / unit-x / internalPorts / port-y, Configuration - PHY 257
Table 154: PM counter interval availability 257
Table 155: PM group: MIB-2 Interface Table 257
Table 156: AP: / unit-x / internalPorts / port-y, Status - PHY 258
Table 157: AP: / unit-x / internalPorts / port-y / eos, Main - Admin And Oper Status 259
Table 158: AP: / unit-x / internalPorts / port-y / eos, Configuration - General 260
Table 159: AP: / unit-x / internalPorts / port-y / eos, Fault Management 261
Table 160: PM counter interval availability 262
Table 161: PM group: EoS GFP Encapsulation 262
Table 162: AP: / unit-x / internalPorts / port-y / eos, Status - General 263
Table 163: AP: / unit-x / internalPorts / port-y / eos / vcx-a, Main - Admin And Oper Status 264
Table 164: AP: / unit-x / internalPorts / port-y / eos / vcx-a, Configuration - CTP 265
Table 165: AP: / unit-x / internalPorts / port-y / eos / vc4-a, Fault Management 266
Table 166: AP: / unit-x / internalPorts / port-y / eos / vc3-a, Fault Management 267
Table 167: AP: / unit-x / internalPorts / port-y / eos / vc12-a, Fault Management 269
Table 168: PM counter interval availability 270
Table 169: PM group: G.826 270
Table 170: PM group: Unfiltered Events 270
Table 171: AP: / unit-x / internalPorts / port-y / eos / vcx-a, Status - General 271
Table 172: AP: / unit-x / internalPorts / port-y / eos / vcz-a, Status - EoS 272
Table 173: AP: / unit-x / internalPorts / port-y / eos / vcx-a, Status - CTP 273
14 FOX61xSAMO1
PREFACE
1 Preface
1.1 Precautions and safety
Before you handle any equipment you must comply with the safety advices.
Adherence to the safety instructions ensures compliance with the safety
requirements as defined in EN 60950 (Safety of Information Technology
Equipment).
Please refer to the following document:
1KHW002497 FOX61x Precautions and Safety.
Please note:
Shows significant information.
→ Possible actions are given.
FOX61xSAMO1 15
PREFACE
16 FOX61xSAMO1
INTRODUCTION
2 Introduction
This section presents a general introduction to the use of this document and
the unit it describes.
The section is closed with a unit view in section Installation (page 31) and a
block diagram overview in section Block diagram (page 19).
2.1 General
This document describes the architecture and functions of the SAMO1 unit
and shows, how this unit is commissioned and operated as part of the FOX.
The SAMO1 is a 1 slot wide functional unit of FOX615 and FOX612. The
SAMO1 unit is an SDH unit, providing four SDH interfaces, four Ethernet
interfaces, PBUS access (FOX internal TDM bus) and also connects to the
Gb-Ethernet star (FOX internal Ethernet connection to the core unit).
The SAMO1 unit can be configured as an SDH access system with termina-
tion and add/drop functionality from STM-4 and STM-1 trunks. Typical appli-
cations are the termination of STM-4 or STM-1 traffic from an STM-4 or
STM-1 trunk in linear networks (terminal multiplexer TM) and add/drop of
VC-n traffic in linear or ring networks (add/drop multiplexer ADM).
The following SDH interfaces are supported:
• two interfaces STM-4 or STM-1:
− STM-4 optical or
− STM-1 electrical or optical,
• two interfaces STM-1:
− STM-1 electrical or optical.
The interfaces can be used as aggregate interfaces for the transmission of
STM-4 or STM-1 traffic into the transport network, or as tributary interfaces
for the access of subtended network elements. The aggregate or tributary
usage of an interface is independent of the SAMO1 configuration.
The interfaces are implemented on SAMO1 with four SFP cages, allowing to
plug in any compatible SFP module according to the network application.
The SAMO1 unit implements also the synchronous equipment timing source
(SETS) for the unit.
FOX61xSAMO1 17
INTRODUCTION
2x
2x
STM-4 /
STM-1
STM-1
4x 4x 1x 1x SAMO1
AU-4 AU-4 AU-4 AU-4
AU-4 Cross Connect
8x 24 x 504 x
or or
VC-4 TU-3 TU-12
TU-3 and TU-12 Cross Connect
9x 100 x 67 x
VC-3 VC-12 VC-12
EoS P-12
2 x Mux 2:1
4x Gb Ethernet PBUS
10/100/1000
BASE-T
The SAMO1 unit accesses Ethernet services via the units four electrical 10/
100/1000BASE-T front interfaces and the Gb-Ethernet star from the CESM1
core unit(s).
Ethernet traffic is transported over up to four Ethernet over SDH (EoS) chan-
nels. Two of the four EoS channels are shared with the connections to the
Gb-Ethernet star. The Gb Ethernet star connects the SAMO1 unit to the
working and protecting CESM1 core units.
FOX
FXO FXS STM-4
TDM
LESU1 Network
West
E1
DTE LEDE1
SAMO1
data STM-4
TDM
DTE LEDS1 Network
East
Ethernet
DTE
The SAMO1 unit accesses TDM services via PBUS. Up to 67 P12 tributary
signals can directly be accessed.
18 FOX61xSAMO1
INTRODUCTION
Figure 3 shows the SAMO1 unit hardware. On the front plate are two LEDs
for unit- and traffic failure indication.
Figure 4 shows the block diagram of the SAMO1 unit. The main functions of
the SAMO1 unit can be divided into the following five parts:
• SDH terminal multiplexer or add/drop multiplexer with four SDH inter-
faces: 2 x STM-4/STM-1 and 2 x STM-1.
• SDH cross connect system for 18 x 18 AU-4.
• SDH cross connect system for 33 x 33 TU-3 or 671 x 671 TU-12.
• Termination to the PBUS of 67 x P12.
• Ethernet over SDH for four Ethernet tributaries with a maximum capacity
of 8 x VC-4. The four Ethernet tributaries are shared between the four
FOX61xSAMO1 19
INTRODUCTION
Ethernet front interfaces and the two GbE connections to the working and
protecting CESM1 unit via the GbE star.
Front LEDs
Front Connectors SAMO1
8 7 6 5 4 3 2 1
STM-1 STM-1/STM-4
Ethernet
Front Interface Front Interface SETS
Front Interface
(SFP) (SFP)
2x AU-4 8x AU-4
AU-4
GFP
Cross Connect
8x AU -4
Board Controller
VCAT / LCAS VC-4 termination
(uP)
TU-3 / TU-12
Cross Connect
VC-3 VC-12
Termination Termination
9x VC-3
100x VC-12 67x VC-12
P12
Termination
2x GbE
67x P12
Backplane Connectors
20 FOX61xSAMO1
FUNCTIONS AND SPECIFICATIONS
This unit is subject to one or several feature licences. The following licences
are available for this unit.
Please note:
The SAMO1 unit without the SAMO1_8P12 licence allows you to access the
SDH in SAMO1 from the PBUS with a capacity of 16 x P12.
Each FL includes a set of additional 8 x P12.
Table 5: Standards
Feature Standard Release
SDH transport, ETSI - EN 300 147 (09/2001) r1c
Synchronous digital hierarchy multiplexing struc-
ture
- EN 300 417-1-1 (10/2001)
Generic processes and performance
- EN 300 417-2-1 (10/2001)
SDH and PDH physical section layer functions
- EN 300 417-3-1 (10/2001)
STM-N regenerator and multiplex section layer
functions
- EN 300 417-4-1 (10/2001)
SDH path layer functions
FOX61xSAMO1 21
FUNCTIONS AND SPECIFICATIONS
22 FOX61xSAMO1
FUNCTIONS AND SPECIFICATIONS
FOX61xSAMO1 23
FUNCTIONS AND SPECIFICATIONS
3.3 Specifications
24 FOX61xSAMO1
FUNCTIONS AND SPECIFICATIONS
FOX61xSAMO1 25
FUNCTIONS AND SPECIFICATIONS
26 FOX61xSAMO1
FUNCTIONS AND SPECIFICATIONS
FOX61xSAMO1 27
FUNCTIONS AND SPECIFICATIONS
28 FOX61xSAMO1
FUNCTIONS AND SPECIFICATIONS
The SDH interfaces of the SAMO1 unit are implemented with SFP cages
where different SFP pluggable modules can be inserted providing STM-4
and/or STM-1 front interfaces.
The SFP modules are standardised modules following the SFP – MSA
(Multi-Source Agreement) and are implemented according to INF-8074.
For more information please refer to section SFP modules (page 32).
The table below shows the implementation restrictions that are specific for
the SAMO1 unit.
FOX61xSAMO1 29
FUNCTIONS AND SPECIFICATIONS
30 FOX61xSAMO1
INSTALLATION
4 Installation
This section presents the prerequisites for the installation of the SAMO1 unit
in sections Prerequisites (page 31) and Slots for the SAMO1 unit (page 31).
Section SFP modules (page 32) lists the available SDH interface types and
gives instructions for the SFP module handling.
Section Compatibility (page 34) gives information about the compatibility with
previous ESW releases and other FOX units while section Connections and
cables (page 35) handles any external connections and cables.
4.1 Prerequisites
Before installing a SAMO1 unit take care to follow the safety advice as listed
in 1KHW002497 FOX61x Precautions and Safety.
Valid combinations of hardware (HW) and embedded software (ESW) ver-
sions are given in 1KHW002459 FOX61x Release Notes.
For the installation of FOX HW, refer to 1KHW002461 FOX615 Installation-
and refer to 1KHW002462 FOX612 Installation.
FOX61xSAMO1 31
INSTALLATION
Please note:
The SFP transceiver modules must be mounted by the customer.
32 FOX61xSAMO1
INSTALLATION
To insert SFP modules, the bail latch should be in the locked position. The
module is oriented so that the bail is on the right side of the SFP. The mod-
ule is pushed into the SFP cage carefully until a clicking sound indicates that
the module is locked.
SFP module SFP module
bail in locked position bail in open position
install remove
Tx Tx
Rx Rx
Tx/Rx Tx/Rx
(Bidi) (Bidi)
Figure 5: SFP module handling
After disconnection of the optical cable, SFP modules can be removed from
the SFP cage by using the metal bail latch located on the right side of the
SFP module. Pull on the bail to unlock and remove the SFP module.
Please note:
To protect optics, dust covers should always be installed when cables are
not connected.
Please note:
Unplugged SFP modules should be stored in an ESD safe environment.
To insert SFP modules, the module is oriented so that the unlocking actuator
is on the left side of the SFP. The module is pushed into the SFP cage care-
fully until a clicking sound indicates that the module is locked.
FOX61xSAMO1 33
INSTALLATION
SFP module
with unlocking actuator
push
install remove
Tx Tx
Rx Rx
Figure 6: SFP module handling
The SFP modules can be removed from the SFP cage by pushing the
unlocking actuator and then pulling on the module itself or the electrical
cables to remove the SFP module.
Please note:
Unplugged SFP modules should be stored in an ESD safe environment.
4.4 Compatibility
34 FOX61xSAMO1
INSTALLATION
FOX61xSAMO1 35
INSTALLATION
SAMO1 R1A
39700 xxx
pin 1
port-8
pin 8
10/100Base-T 1000Base-T
port-7 Pin
MDI MDI-X MDI MDI-X
1 Tx+ Rx+ D1+ D2+
2 Tx- Rx- D1- D2-
3 Rx+ Tx+ D2+ D1+
port-6 4 D3+ D4+
5 D3- D4-
6 Rx- Tx- D2- D1-
7 D4+ D3+
port-5 8 D4- D3-
port-3
port-2
port-1
Each Ethernet interface provides two LEDs indicating the link activity state
and the link state:
36 FOX61xSAMO1
INSTALLATION
Activity
Link
FOX61xSAMO1 37
INSTALLATION
Please note:
The above cables can be ordered directly from ABB.
Please note:
The electrical interface requires two cables.
Please note:
The above cable can be ordered directly by ABB.
Please note:
The electrical interface requires two cables.
Please note:
The above cable can be ordered directly ABB.
38 FOX61xSAMO1
INSTALLATION
Please note:
The latching clips of the connectors must be positioned to the left to insert
the connector correctly.
Please note:
The Ethernet cables can be ordered directly from ABB
FOX61xSAMO1 39
INSTALLATION
<x> mm
120 mm
<x> mm
120 mm
<x> mm
Figure 12: Side view of the FOX615 cable tray and cables
The open cable length <x> between the cable fixing point on the cable tray
and the connector depends on the connected interface.
Please note:
The cable route on the cable tray should follow approximately the projection
of the unit slot on the cable tray.
Please note:
Do not exceed the specified bending radius or squeeze the optical fibres
when fixing the fibres to the cable tray.
Stressing the fibres in excess to the specified parameters or squeezing the
fibres can permanently degrade the performance of the optical fibres.
40 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
5 Functional Description
This section gives the detailed functional description of the SAMO1 unit as
an SDH terminal multiplexer and add/drop multiplexer in the FOX subrack:
• Applications as multiplexer and Ethernet transport unit (section Applica-
tions (page 41)).
• SDH multiplexing functions (section SDH multiplexing (page 51)).
• SDH layers in SAMO1 and their functions (section SDH layers and func-
tions (page 53)).
• PDH layers in SAMO1 and their functions (section PDH layers and func-
tions (page 59)).
• Ethernet over SDH transport functions (section EoS layers and functions
(page 60)).
• Synchronisation functions and timing distribution (section Synchronisation
and timing functions (page 71)).
• Equipment and traffic protection functions (section Protection (page 72)).
5.1 Applications
FOX61xSAMO1 41
FUNCTIONAL DESCRIPTION
SDH
access
network
STM-4/
Network side STM-1
FOX SAMO1
IP service
units
Tributary side
Figure 13: SDH terminal multiplexer, unprotected
42 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
SDH
access
network
STM-4/ STM-4/
Network side STM-1 STM-1
FOX SAMO1
IP service
units
Tributary side
Figure 14: SDH terminal multiplexer, MSP protected
Please note:
MSP protection is available within a single SAMO1 unit only.
→ MSP protection distributed over two SAMO1 units is not feasible.
FOX61xSAMO1 43
FUNCTIONAL DESCRIPTION
switch connecting the front interfaces, or via the GbE star. The Ethernet traf-
fic must have RSTP enabled to avoid a packet loop.
SDH SDH
access access
network network
STM-4/ STM-4/
STM-1 STM-1
CESM1 port-5 port-6 port-7 port-8 CESM1 CESM1 port-5 port-6 port-7 port-8
SDH SDH
access access
network network
STM-4/ STM-4/
STM-1 STM-1
star-1 port-5 port-6 port-7 port-8 star-1 port-5 port-6 port-7 port-8
2:1 Mux
GbE star
CESM1 CESM1
Please note:
When using the GbE star for the Ethernet transport to the SAMO1 unit, the
Ethernet front port-5 on the SAMO1 unit is no longer usable.
44 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
SDH SDH
access access
network network
STM-4/ STM-4/
STM-1 STM-1
Network side west east
FOX SAMO1
IP service
units
Tributary side
FOX61xSAMO1 45
FUNCTIONAL DESCRIPTION
SDH SDH
access access
network network
STM-1
west STM-1 STM-1 STM-1
protecting west east east
Network side working working protecting
FOX SAMO1
IP service
units
Tributary side
Please note:
MSP protection is available within a single SAMO1 unit only.
MSP protection distributed over two SAMO1 units is not feasible.
46 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
SDH SDH
access access
network network
STM-4/ STM-4/
STM-4/
STM-1 STM-1
Network side west STM-1
east
Tributary side
Please note:
With EQP the SDH traffic terminated to the PBUS and the EoS traffic is pro-
tected. The tributary SDH traffic is not protected.
The two SAMO1 units must be interconnected with an external (optical)
cable for the through traffic and to give access to the east and west uplinks
to both SAMO1 units.
This setup offers four STM-1 tributary ports. These ports can be handled
• as four independent tributary ports or
• as ports for two subtending rings (unprotected) or
• as ports for one subtending ring (protected, with an external link intercon-
necting two STM-1 ports on SAMO1 west and SAMO1 east) or
• as two MSP protected STM-1 tributaries.
FOX61xSAMO1 47
FUNCTIONAL DESCRIPTION
p-5 p-6 p-7 p-8 p-5 p-6 p-7 p-8 p-5 p-6 p-7 p-8 p-5 p-6 p-7 p-8
CESM1 CESM1 CESM1
p-x = port-x
48 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
star-1 port-5 port-6 port-7 port-8 star-1 star-2 port-5 port-6 port-7 port-8
s-1 p-5 p-6 p-7 p-8 s-1 p-5 p-6 p-7 p-8 s-1 p-5 p-6 p-7 p-8 s-1 p-5 p-6 p-7 p-8
p-x = port-x
s-x = star-x
Please note:
When using the GbE star for the Ethernet transport to the SAMO1 unit and
with one CESM1 unit and only one SAMO1 unit providing the SDH connec-
tions to the west and east directions, one of the Ethernet connections from
the CESM1 to the SAMO1 unit must be done via a front connection.
Please note:
When using the GbE star for the Ethernet transport to the SAMO1 unit, the
Ethernet front port-5 on the SAMO1 unit is no longer usable.
With CESM1 redundancy and only one SAMO1 unit providing the SDH con-
nections to the west and east directions, the Ethernet front port-5 and port-6
on the SAMO1 unit are no longer usable.
FOX61xSAMO1 49
FUNCTIONAL DESCRIPTION
Ethernet
FOX SAMO1
STM-4/
STM-1
SDH
access
network
STM-4/
STM-4/ STM-1
STM-1
FOX SAMO1
FOX SAMO1
Ethernet
Ethernet
Ethernet
Customer
A Customer
B
Customer
B
The SAMO1 unit provides the ability to create point to point Ethernet connec-
tions in SDH networks with its Ethernet tributary ports.
The users have access to dedicated Ethernet channels through the SDH
network. Ethernet traffic is encapsulated in SDH using the GFP framing pro-
cedure.
Ethernet traffic is transported in virtually concatenated VC-4, VC-3 or VC-12.
The Ethernet traffic from different Ethernet tributary ports is completely sepa-
rated.
50 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
x4
x1 x1
STM-1 AUG-1 AU-4 VC-4 C-4
x 3* x3
x1
TUG-3 TU-3 VC-3
x7
x1
STM-0 AU-3 VC-3 C-3
x 7*
x1
Pointer processing TUG-2 TU-2 VC-2 C-2
Multiplexing x3
Mapping
* not defined in ETSI EN 300 147 x 4*
TU-11 VC-11 C-11
x4
x1 x1
STM-1 AUG-1 AU-4 VC-4 C-4
x3
x1
TUG-3 TU-3 VC-3 C-3
x7
x3
Pointer processing TUG-2 TU-12 VC-12 C-12
Multiplexing
Aligning
Mapping
FOX61xSAMO1 51
FUNCTIONAL DESCRIPTION
Gb Ethernet PBUS
The functional blocks implemented in the SAMO1 unit are shown in the fig-
ure above. The figure shows also the numbers of available functional blocks.
E.g. the number of TU-12 processing blocks is
8 (VC-4) x 3 (TUG-3) x 7 (TUG-2) x 3 (TU-12) = 504.
The STM-4 and STM-1 output signals are frequency locked to the SETS
(Synchronous Equipment Timing Source) timing.
52 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
5.3.1 PS layer
The optical section (OS) layer or electrical section (ES) layer of the SAMO1
unit are handled in a common layer called physical section (PS). The physi-
cal section provides the following functions:
• Termination of the optical or electrical section. The optical section can be
STM-4 or STM-1. The electrical section is STM-1.
− Optical/electrical converter
− Receive signal regeneration
− Clock and data recovery
− STM-4 or STM-1 frame alignment
• Control of laser shutdown and restart (OS only)
− Automatic laser shutdown (ALS) automatically switches off the optical
transmitter if there is a broken or missing cable in the section.
− The automatic laser restart (ALR) function automatically restarts the
laser after an automatic shutdown. After ALS the interface monitors
the input for an appropriate laser signal and restarts its laser if the
received signal remains stable for a defined period of time. In addition
the interface periodically restarts its laser and monitors the input for an
appropriate laser signal.
ALS and ALR are implemented according to ITU-T G.664.
5.3.2 RS layer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1080
1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 J0 Z0 Z0 Z0 NU NU NU NU NU NU NU NU
2 B1 E1 F1
3 D1 D2 D3
4 H1 H1 H1 H1 Y Y Y Y Y Y Y Y H2 H2 H2 H2 ´1´ ´1´ ´1´ ´1´ ´1´ ´1´ ´1´ ´1´ H3 H3 H3 H3 H3 H3 H3 H3 H3 H3 H3 H3 STM-4 payload
(4 x 261 x 9 bytes )
5 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 K1 K2
6 D4 D5 D6
7 D7 D8 D9
8 D10 D11 D12
9 S1 M1 E2
1 2 3 4 5 6 7 8 9 10 270
1 A1 A1 A1 A2 A2 A2 J0 NU NU
2 B1 E1 F1
3 D1 D2 D3
4 H1 Y Y H2 ´1´ ´1´ H3 H3 H3 STM-1 payload
(261 x 9 bytes )
5 B2 B2 B2 K1 K2
6 D4 D5 D6
7 D7 D8 D9
8 D10 D11 D12
9 S1 M1 E2
The regenerator section (RS) layer of the SAMO1 unit provides the following
functions:
• Termination of the STM-4 or STM-1 regenerator section
FOX61xSAMO1 53
FUNCTIONAL DESCRIPTION
− Scrambling/descrambling
− Check of the B1 byte (BIP-8)
The bit interleaved parity (BIP) code BIP-8 determines if a transmis-
sion error has occurred over a path. Its value is calculated over all bits
of the previous scrambled STM-4 or STM-1 and placed in the current
frame.
The evaluation of the B1 byte is used for the performance monitoring
function.
− Control of the RS trail trace identifier (TTI) in the J0 byte.
The RS TTI function allows the FOX to control the proper connection
of the traffic signal path in a regenerator section via the 16 byte TTI
(15 characters).
− Access to the RS data communication channel (DCC) in the D1 to D3
overhead bytes (192 kbit/s). The DCC is used in FOX for the embed-
ded communication channel (ECC) connected to CESM1.
Please note:
The access to the RS orderwire byte (E1) and user channel byte (F1) is not
supported.
5.3.3 MS layer
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1080
1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 J0 Z0 Z0 Z0 NU NU NU NU NU NU NU NU
2 B1 E1 F1
3 D1 D2 D3
4 H1 H1 H1 H1 Y Y Y Y Y Y Y Y H2 H2 H2 H2 ´1´ ´1´ ´1´ ´1´ ´1´ ´1´ ´1´ ´1´ H3 H3 H3 H3 H3 H3 H3 H3 H3 H3 H3 H3 STM-4 payload
(4 x 261 x 9 bytes )
5 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 B2 K1 K2
6 D4 D5 D6
7 D7 D8 D9
8 D10 D11 D12
9 S1 M1 E2
1 2 3 4 5 6 7 8 9 10 270
1 A1 A1 A1 A2 A2 A2 J0 NU NU
2 B1 E1 F1
3 D1 D2 D3
4 H1 Y Y H2 ´1´ ´1´ H3 H3 H3 STM-1 payload
(261 x 9 bytes )
5 B2 B2 B2 K1 K2
6 D4 D5 D6
7 D7 D8 D9
8 D10 D11 D12
9 S1 M1 E2
The multiplex section (MS) layer of the SAMO1 unit provides the termination
of the STM-4 or STM-1 multiplex section with the following functions:
• Access to the M1 byte for the remote error indication or AIS indication.
The M1 byte indicates the number of remote BIP-96 or BIP-24 errors as
described in ITU-T G.707.
• Access to the K2[6-8] byte for the remote defect indication.
• Access to the B2 bytes (BIP-96 or BIP-24).
The bit interleaved parity (BIP) code BIP-96 (for STM-4) or BIP-24 (for
STM-1) determines if a transmission error has occurred over a path. Its
54 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
value is calculated over all bits of the previous STM-4 except the regener-
ator section overhead and placed in the current frame.
The evaluation of the degraded bit error ratio of the MS traffic assumes a
bursty error distribution. The following parameters can be defined:
− degraded monitoring period (DEGM): 2 … 10 [bad sec]
− degraded threshold (DEGTHR): 0 … 100 [% bad blocks]
• Access to the synchronisation status message (SSM) byte S1.
The SSM mode allows the FOX to transmit and receive synchronisation
status messages with the traffic signal. The FOX internally processes this
information for the selection of the SETS timing source.
The SSM processing at the port level provides
− an input mapping table which maps the quality level (QL) received
with the traffic signal to some other value.
− an output mapping table which maps the intrinsic QL for the transmis-
sion with the traffic signal to some other QL.
− a routing table which allows the SAMO1 to mark the transmitted traffic
signals depending on the selected traffic source as “can be used” or
“do not use” for synchronisation purposes.
• Access to the automatic protection switching (APS) channel in the K1 and
K2[1-5] bytes. Please refer to section Multiplex section protection (MSP)
(page 72).
• Access to the MS data communication channel (DCC) in the D4 to D12
overhead bytes (576 kbit/s). The DCC is used in FOX for the embedded
communication channel (ECC) connected to CESM1.
• Multiplexing and demultiplexing of the 4 AU-4 to/from the STM-4 or STM-
1.
• Pointer generation and interpretation for all AU-4.
• Frequency adaptation to the SETS clock.
Please note:
The access to the MS orderwire byte (E2) is not supported.
Please note:
The 8 tributary AU-4 limit the amount of traffic that can be brought to the
SDH front interfaces from the Ethernet interfaces, the GbE star and the
PBUS.
FOX61xSAMO1 55
FUNCTIONAL DESCRIPTION
The VC-4 layer of the SAMO1 unit is used in the EoS (VC-4) application and
as an intermediate layer towards the lower order (LO) layers (VC-3, VC-12).
It provides the termination of the VC-4 path overhead with the following func-
tions:
• Control of the VC-4 trail trace identifier (TTI) in the J1 byte.
The VC-4 TTI function allows the FOX to control the proper connection of
the traffic signal path in an SDH network via the 16 byte TTI (15 charac-
ters).
Note that there is one transmitted TTI per virtual concatenation group
(VCG), used in every group member. The received TTI is available for
every group member.
• Access to the B3 byte (BIP-8).
The bit interleaved parity (BIP) code BIP-8 determines if a transmission
error has occurred over a path. Its value is calculated over all bits of the
preceding VC-4.
The evaluation of the degraded bit error ratio of the VC-4 assumes a
bursty error distribution. The following parameters can be defined in com-
mon for all VC-4 on the SAMO1 unit:
− degraded monitoring period (DEGM): 2 … 10 [bad sec]
− degraded threshold (DEGTHR): 200 … 4’000 [bad blocks]
• Access to the C2 byte for the signal label insertion and extraction. The
received signal label is displayed in the FOXCST, together with a consist-
ency indication.
• Access to the G1[1-4] byte for the remote error indication.
The G1[1-4] byte indicates the number of remote BIP-8 errors as
described in ITU-T G.707.
• Access to the G1[5] byte for the remote defect indication.
The G1[5] byte remote defect indication can be displayed in FOXCST.
Please note:
The access to the VC-4 user channel bytes (F2, F3), to the automatic protec-
tion switching channel byte (K3) and to the tandem connection monitoring
byte (N1) is not supported.
56 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
The VC-3 layer of the SAMO1 unit is used in the EoS application. It provides
the termination of the VC-3 path overhead with the following functions:
• Control of the VC-3 trail trace identifier (TTI) in the J1 byte.
The VC-3 TTI function allows the FOX to control the proper connection of
the traffic signal path in an SDH network via the 16 byte TTI (15 charac-
ters).
Note that there is one transmitted TTI per virtual concatenation group
(VCG), used in every group member. The received TTI is available for
every group member.
• Access to the VC-3 path overhead B3 byte (BIP-8).
The bit interleaved parity (BIP) code BIP-8 determines if a transmission
error has occurred over a path. Its value is calculated over all bits of the
preceding VC-3.
The evaluation of the degraded bit error ratio of the VC-3 assumes a
bursty error distribution. The following parameters can be defined in com-
mon for all VC-3 on the SAMO1 unit:
− degraded monitoring period (DEGM): 2 … 10 [bad sec]
− degraded threshold (DEGTHR): 200 … 4’000 [bad blocks]
• Access to the signal label in the C2 byte for the signal label insertion and
extraction.
• Access to the G1[1-4] byte for the remote error indication.
• Access to the G1[5] byte for the remote defect indication.
Please note:
TThe access to the VC-3 user channel bytes (F2, F3), to the automatic pro-
tection switching channel byte (K3) and to the tandem connection monitoring
byte (N1) is not supported..
FOX61xSAMO1 57
FUNCTIONAL DESCRIPTION
The VC-12 layer of the SAMO1 unit is used for the EoS application and for
the PBUS access application. It provides the termination of the VC-12 path
overhead with the following functions:
• Control of the VC-12 trail trace identifier (TTI) in the J2 byte.
The VC-12 TTI function allows the FOX to control the proper connection
of the traffic signal path in an SDH network via the 16 byte TTI (15 char-
acters).
Note that there is one transmitted TTI per virtual concatenation group
(VCG), used in every group member. The received TTI is available for
every group member.
• Access to the VC-12 path overhead V5[1-2] byte (BIP-2).
The bit interleaved parity (BIP) code BIP-2 determines if a transmission
error has occurred over a path. Its value is calculated over all bits of the
preceding VC-12.
The evaluation of the degraded bit error ratio of the VC-12 assumes a
bursty error distribution. The following parameters can be defined in com-
mon for all VC-12 on the SAMO1 unit:
− degraded monitoring period (DEGM): 2 … 10 [bad sec]
− degraded threshold (DEGTHR): 200 … 1000 [bad blocks]
• Access to the RFI bit in the V5[4] byte in the PBUS access application.
This bit is used to indicate to the remote VC-12 termination function the
state of the SNCP selector:
− Working path selected: RFI = 0,
− Protecting path selected: RFI = 1.
This procedure is ABB proprietary.
• Access to the signal label in the V5[5-7] byte for the signal label insertion
and extraction.
• Access to the V5[3] byte for the remote error indication.
• Access to the V5[8] byte for the remote defect indication.
Please note:
The access to the VC-12 automatic protection switching channel byte (K4)
and to the tandem connection monitoring byte (N2) is not supported.
The VC-12 layer makes also use of the multiframe synchronisation con-
tained in the H4 byte of the VC-4 path overhead.
58 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
Please note:
The transparent mode features clock transparent cross connections. That
means that the signal is in a plesiochronous phase relationship with the NE
timing source.
• Clock master
Unlike the transparent mode, a clock master traffic signal is only cross
connected transparently in terms of its structure. The P12 output signal is
always resynchronised by the NE timing source. The input signal must be
synchronous to the output signal in order to avoid bit slips.
For details of the clock master mode, please refer to 1KHW002467
FOX61x TDM Services.
• V5.x applications (P12 mode: V5 Uplink, V5 Uplink NCI)
The V5 Uplink modes are application specific modes used together with
the V5 protocol converter unit PCOM1 or PCOM2. V5.x applications ter-
minate the P12 signal and use all 5 Sa bits.
With V5.1 the Sa bits are fixed. With V5.2 Sa7 is used for the link identifi-
cation control.
The “V5 uplink” mode supports the CRC4 processing in time slot 0, the
“V5 uplink NCI” mode doesn’t supports the CRC4 processing.
For details of the V5 uplink modes, please refer to refer to FOX61x TDM
Services Manual.
Please note:
The V5.x application is not part of the FOX61x R1 release.
The SAMO1 unit offers maintenance loops at the P12 layer.
FOX61xSAMO1 59
FUNCTIONAL DESCRIPTION
Please note:
Be aware that when connecting Ethernet ports configured in manual mode
on SAMO1 (no auto-negotiation) to Ethernet ports in auto-negotiation mode,
the following situation may occur:
The link will be up but the duplex settings may be inconsistent and this can
result on poor throughput performance on the link.
The previous note applies to any Ethernet device and is a consequence of
the behaviour of auto-negotiation and parallel detection. When a port sup-
porting auto-negotiation is connected to a port not supporting auto-negotia-
tion, the port supporting auto-negotiation will revert to parallel detection. This
can detect the link type (e.g. 10BASE-T or 100BASE-TX) but will assume
half-duplex operation (reference IEEE 802.3 clause 28.2.3.1 note 2). If the
far side port is manually configured in full-duplex mode then there is an
inconsistent configuration and the side operating in half-duplex may experi-
ence collisions while transmitting data.
60 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
The Ethernet functional layer allows using IEEE 802.3x flow control.
Flow control is a mechanism which allows inhibiting transmission of data
frames for a specified period of time. This is normally used when the receive
data buffer is almost full. This state is indicated to the transmitter to stop the
transmission of frames for the specified period of time.
The buffer sizes in transmit and receive direction are not the same on all
ports.
• Port 5 and 6 have a 256 kByte buffer size in transmit direction and a
16 kByte buffer size in receive direction.
• Port 7 and 8 have an 8 kByte buffer size in transmit and in receive direc-
tion.
For transporting big amounts of Ethernet data the Ethernet ports 5 and 6
should be the preferred ports.
In half-duplex mode SAMO1 supports collision-based congestion control.
This operates independently of the setting of the 802.3 flow control configu-
ration parameter in the FOXCST.
SAMO1 also provides the “link pass through” feature. This feature can bring
the local link state (up or down) to the remote Ethernet interface. If the local
link state is down SAMO1 will generate GFP client signal fail management
frames going to the remote site. A failure in the SDH path will interrupt the
GFP connection.
If the GFP receiver on the remote site will receive GFP client signal fail man-
agement frames or no GFP frames at all, it will set the Ethernet interface to
the down state accordingly.
With this feature the Ethernet transport is transparent also for link states.
Please note:
The link pass through feature must be enabled on the Ethernet interfaces at
both sides of the SDH path to become operational.
FOX61xSAMO1 61
FUNCTIONAL DESCRIPTION
FOX SAMO1
2:1 Mux
CESM1 CESM1
The LAN mode on the Gb Ethernet star is fixed to full duplex mode and
1 Gbit/s link speed.
The Ethernet functional layer allows using IEEE 802.3x flow control.
Please note:
The port mode of the CESM1 internal ports that are used for the SAMO1 unit
must be configured to “VLAN Trunk Port”.
The buffer sizes in transmit and receive direction are as follows:
• 256 kByte buffer size in transmit direction and a 16 kByte buffer size in
receive direction.
The different applications as described in the section Ethernet over an SDH
terminal multiplexer (page 43) and Ethernet over an SDH add/drop multi-
plexer (page 48) make different use of the Gb Ethernet connections to the
working and, if available, to the redundant CESM1 unit. The required config-
uration of the SAMO1 internal ports are described in the sections below.
Configure the “Internal Port Usage” parameter at the AP: /unit-x, Configura-
tion - General - EoS Resource Usage to
“Use Internal Port 1 to unit-11/13”.
With this configuration, the SAMO1 internal multiplexers are set as shown in
Figure 32. The SAMO1 unit autonomously selects the path to the active
CESM1 unit. The path to the redundant CESM1 is disabled. The external
port-5 cannot be used in this application.
62 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
Select Select
internal SAMO1 internal SAMO1
port-1 port-1
11 is active 13 is active
slot-11 slot-13 port-5 port-6 slot -11 slot -13 port-5 port-6
CESM1 CESM1
GbE star
CESM1
FOX61xSAMO1 63
FUNCTIONAL DESCRIPTION
5.5.2.2 Internal ports with two CESM1 units and one SAMO1 unit
Configure the “Internal Port Usage” parameter at the AP: /unit-x, Configura-
tion - General - EoS Resource Usage to
“Use Internal Port 1 And 2”.
With this configuration, the SAMO1 internal multiplexers are set as shown in
Figure 34. The SAMO1 unit selects for the internal port-1 the path to the
CESM1 unit in slot-11 and selects for the internal port-2 the path to the
CESM1 unit in slot-13.
CESM1 CESM1
5.5.2.3 Internal ports with two CESM1 units and two SAMO1 units
Configure the “Internal Port Usage” parameter at the AP: /unit-x, Configura-
tion - General - EoS Resource Usage to
“Use Internal Port 1 To unit-11” on the first SAMO1 unit,
“Use Internal Port 1 To unit-13” on the second SAMO1 unit.
With this configuration, the SAMO1 internal multiplexers are set as shown in
Figure 35. The first SAMO1 unit selects for the internal port-1 the path to the
CESM1 unit in slot-11 and the second SAMO1 unit selects for the internal
port-1 the path to the CESM1 unit in slot-13.
64 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
Select Select
internal internal
SAMO1 SAMO1
port-1 port-1
slot -11 slot -13 port-5 port-6 slot -11 slot -13 port-5 port-6
CESM1 CESM1
The SAMO1 unit implements GFP according to ITU-T G.7041. This recom-
mendation defines the required procedures for transporting variable length
frames over SDH transport paths.
GFP provides a unified way to encapsulate and transport client signals
instead of application specific mapping protocols.
G.7041 defines two GFP modes of operation:
• Frame mapped GFP
A single client frame is mapped into a single GFP frame.
• Transparent GFP
FOX61xSAMO1 65
FUNCTIONAL DESCRIPTION
A number of client data characters are mapped into efficient block codes
for transport within a GFP frame.
SAMO1 supports frame mapped GFP.
GFP supports two types of frames:
• Client frames
Client frames transport client data (client data frame) or management
information (client management frame).
• Control frames
Control frames are used as idle frames, i.e. when no client data has to be
transported.
The basic signal structure of a GFP client frame is shown in the figure below.
GFP frames are octet aligned and consist of a GFP core header and a GFP
payload area, i.e. a payload header and a payload information field.
A GFP control frame consists of a core header only.
GFP frame
Payload Length
16 bit
Indicator
Core
Header
Core Header
16 bit
Error Check
PTI PFI EXI 8 bit
Type
Ethernet MAC frame Payload UPI 8 bit
Preamble Header
Type Header
16 bit
Start of frame Error Check
Destination Address
Source Address
Length / Type
Payload
Information up to 1600 octets
MAC client data Field
Pad
Frame Check Sequence
Inter-Packet Gap
PTI: payload type identifier = 000 (client data)
= 100 (client management)
PFI: payload FCS identifier = 0 (no GFP FCS)
EXI: extension header identifier = 0000 (null extension header)
UPI: user payload identifier = 0000 0001 (frame mapped Ethernet)
SAMO1 implements the following payload header type fields for client data:
66 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
The payload information field contains the framed PDU. The client PDU is
always transferred into the GFP payload information field as an octet aligned
packet stream.
The GFP payload contains the Ethernet MAC frame excluding the Ethernet
‘preamble’ and ’start of frame’ bytes but including the Ethernet FCS.
SAMO1 implements the following payload header type fields for client man-
agement:
Client management frames are used to propagate a client signal fail (CSF)
indication to the far end. In case of a Link Down, the SAMO1 generates cli-
ent management GFP frames once every 100 – 150 ms. The GFP CSF con-
dition will be cleared after 3 s, if no GFP CSF frames are received, or upon
receiving a valid GFP client data frame.
The GFP frame stream is mapped into a container-n or virtually concate-
nated container-n-Xv (n = 12, 3, 4) with its byte boundaries aligned with the
byte boundaries of the container. The container is then mapped into the VC-
n, or VC-n-Xv respectively, together with the associated path overhead.
The GFP frame boundaries are thus aligned with the VC-n byte boundaries.
Since the container-n capacity is not an integer multiple of the variable
length GFP frame, a GFP frame may cross a container-n frame boundary.
GFP frames arrive as a continuous byte stream with a capacity that is identi-
cal to the VC payload, due to the insertion of GFP idle frames at the GFP
adaptation stage.
FOX61xSAMO1 67
FUNCTIONAL DESCRIPTION
The total number of members that are available for each group is directly
related to the maximum tributary capacity of SAMO1 which is 8 x VC-4.
In the case that more than 3 x VC-4 shall be used, the SAMO1 resource
manager has to take the capacity from the VC-3 or VC-12 resources. In the
unit configuration the resource usage strategy can be configured. Refer to
section Resource usage strategy (page 107).
1 4 3 2 5 4 3 2 1
2
2 4 3 2 5 4 3 2
Frame split over each 3
link according to the
3 4 3 2 1 5 4 3 2
sequence indicators
The sequence indicator and the frame count are transported in the VC path
overhead of every virtual container.
68 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
FOX61xSAMO1 69
FUNCTIONAL DESCRIPTION
FOXCST/
FOXMAN-UN
add/remove
link request
VCG
VCG member
LCAS control packets
VCG member
LCAS control packets
VCG member
LCAS control packets
70 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
IP IP
DCC PPP
It is also possible to use a partially or completely filled P12 for the ECC
transport. The P12 is transported in a VC-12.
The EPSI1 unit is used the same way as with the ECC over DCC transport.
Management
VC-12
OSPFv2 interface
IP IP
VC-12/P12 PPP
For a description of the SAMO1 and FOX synchronisation and timing func-
tions please refer to 1KHW002467 FOX61x TDM Services.
FOX61xSAMO1 71
FUNCTIONAL DESCRIPTION
5.8 Protection
72 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
working working
SDH
access
protecting network protecting
SAMO1
4 x AU-4 4 x AU-4
AU-4 Cross Connect AU-4 Cross Connect
Figure 41: 1+1 MSP (only one direction of the MS trail is shown)
FOX61xSAMO1 73
FUNCTIONAL DESCRIPTION
• Forced switch
Switches the active channel to the subunit where the command has been
applied to, unless an equal or higher priority switch command is in effect.
Since a forced switch has higher priority than SF or SD on the working
channel, this command will be carried out regardless of the condition of
the working channel.
Note that an SF condition on the protecting channel has higher priority
than a forced switch. Therefore it is not possible to switch from the work-
ing channel to the protecting channel if this channel has SF.
• Manual switch
Switches the active channel to the subunit where the command has been
applied to, unless an equal or higher priority switch command is in effect
or an SF condition exists on this channel.
Since manual switch has lower priority than SF or SD on a working or
protecting channel, this command will be carried out only if the channel is
not in SF or SD condition.
• Exercise
Effective for the bidirectional MSP mode and working channel only.
This command checks the responses of automatic protection switching
(APS) bytes to a switch request, unless the protecting channel is in use.
The switch is not actually completed for the traffic signal.
The remote request will display a “Reverse request”.
Each request (signal, external) has a fixed priority. These priorities allow the
MSP to select the request with the highest priority if there is more than one
request pending. The table below lists the requests with the corresponding
priorities according to ITU-T G.841.
a. An SF condition on the protection section is higher priority than any of the requests
that would cause a working channel to be selected from the protection section.
b. Only the null signal (0), i.e. the protecting channel, is allowed with a lockout of pro-
tection request.
74 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
c. Some network operators may use these codes for network specific purposes. The
receiver is capable of ignoring these codes.
In the bidirectional MSP mode it is possible to indicate locally the requests
issued by the remote interface. This information is transmitted via the K1/K2
bytes in the SOH.
Beside the signal requests and external requests there is a protocol failure
which can actuate a protection switching. FOP (failure of protocol) is availa-
ble only for the bidirectional MSP mode. The FOP switchover has a higher
priority than all the other requests above.
Failure of protocol:
• Failure of protocol (FOP) driven switchover
If the protocol in the protecting channel fails, the system generates a FOP
failure and switches the traffic signal to the working channel.
For example, the FOP failure (alarm) is generated if a switch command
issued from an interface in bidirectional MSP mode receives no answer
from the remote interface that operates in unidirectional MSP mode.
Please note:
The protocol for the bidirectional protection mode is always running on the
protecting channel (channel 0).
Please note:
When using the DCC in the regenerator or multiplex section overhead for
ECC, please note that
→ MSP affects payload traffic only. The channels in the SOH are not pro-
tected with the configuration of MSP.
→ Accordingly, the MSP maintenance functions do not affect the chan-
nels in the SOH.
→ the ECC, transported in the DCC bytes, is taken from the unprotected
side, i.e. protection of the ECC is done in the management communi-
cation network. Note that this doubles the required capacity on the
PBUS.
FOX61xSAMO1 75
FUNCTIONAL DESCRIPTION
76 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
working working
SDH
access
protecting network protecting
SAMO1
AUG-4 AUG-4 AUG-4 AUG-4
x4 x4 x4 x4
AUG-1 AUG-1 AUG-1 AUG-1
AU-4
AU-4 Cross Connect
VC-4 protection switching takes place in the higher order cross connect (AU-
4 cross connect).
Protection switching action can be driven by two different request types:
FOX61xSAMO1 77
FUNCTIONAL DESCRIPTION
Note that a manual switch is executed only when there is no failure on the
target signal. The command is a maintenance function, i.e. it is not stored in
the units database.
working working
SDH
access
protecting network protecting
SAMO1
SAMO1
VC-4 VC-4 VC-4 VC-4
TU-3
TU-3 Cross Connect
VC-3 and VC-12 protection switching takes place in the lower order cross
connect (TU-3 and TU-12 cross connect).
Protection switching action can be driven by two different request types:
78 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
FOX61xSAMO1 79
FUNCTIONAL DESCRIPTION
working working
SDH
access
protecting network protecting
SAMO1
AUG-4 AUG-4 AUG-4 AUG-4
x4 x4 x4 x4
AUG-1 AUG-1 AUG-1 AUG-1
AU-4 AU-4
AU-4 Cross Connect AU-4 Cross Connect
VC-4 protection switching takes place in the higher order cross connect (AU-
4 cross connect).
Protection switching action can be driven by two different request types:
80 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
working working
SDH
access
protecting network protecting
SAMO1
VC-4 VC-4 VC-4 VC-4
TU-3 TU-3
TU-3 Cross Connect TU-3 Cross Connect
VC-3 and VC-12 protection switching takes place in the lower order cross
connect (TU-3 and TU-12 cross connect).
Protection switching action can be driven by two different request types:
FOX61xSAMO1 81
FUNCTIONAL DESCRIPTION
P12 and P0-nc signals connected to a tributary unit, e.g. LEDE1, are termi-
nated or through connected transparently. The signal state of the working
and protecting signal is brought via the PBUS to the SAMO1 unit where the
protection switching takes place.
SNCP/I provides the following functions:
• 1+1 unidirectional protection mode according to ITU-T G.841, § 8.
− The SAMO1 unit selects the received signal from one of the two P12
or P0-nc signals and switches to the other P12 or P0-nc if this signal
fails.
− 1+1 unidirectional protection switching uses no protocol.
− The operation type is revertive or non-revertive (for P0-1c only).
− There is no restriction about the selection of working and protecting
P12 or P0-nc.
In addition SAMO1 supports bidirectional switching type for terminated P12
signals.
This type of protection provides the following functions:
• 1+1 bidirectional protection mode.
− The SAMO1 unit selects the received signal from one of the two P12
signals and switches to the other P12 signal if this signal fails. The fail-
ure state is signalled to the remote termination function with the RDI
which switches its selector accordingly.
− 1+1 bidirectional protection switching uses RDI as protection switching
criterion. Please refer to 1KHW002467 FOX61x TDM Services for fur-
ther information.
− The operation type can be configured to revertive or non-revertive
(P0-1c only).
− The working channel provides the active VC under normal operating
conditions. The protecting channel protects the working channel.
− There is no restriction about the selection of working and protecting
P12 signal.
82 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
SAMO1
VC-12
C-12
P-12
PBUS
P12 P12
E1 E1
LEDE1 LEDE1
P12 and P0-nc protection switching takes place in the P12/P0-nc cross con-
nect function of the PBUS access circuit.
Protection switching action can be driven by two different request types:
FOX61xSAMO1 83
FUNCTIONAL DESCRIPTION
P12 and P0-nc protection switching for signals from the network or aggre-
gate side takes place on a tributary unit, e.g. LEDE1. A P12 or P0-nc signal
transported over the network is received on one or two SAMO1 units as a
working and a protecting signal. The tributary unit performs the selection
according to the signal states of the two signals.
SAMO1 SAMO1
VC-12 VC-12
C-12 C-12
P-12 P-12
PBUS
P12
E1
LEDE1
Figure 47: P12 SNCP/I from the network side with two SAMO1 units
Please note:
The protection parameters holdoff time and guard time are not available for
P12 and P0-nc SNCP.
84 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
SDH
access
network
SAMO1
SAMO1
VC-4 VC-4 VC-4 VC-4
To protect the terminated P12 traffic and Ethernet traffic in an add-drop mul-
tiplexer against SAMO1 hardware failures, the FOX offers the possibility to
equip the subrack with a second SAMO1 unit.
The PDH traffic accessing the PBUS is protected as follows: During normal
operation, the VC-12 traffic on the active unit (working or protecting)
accesses the PBUS, while the VC-12 traffic on the standby unit (protecting
or working) is looped towards the SDH front interfaces and then forwarded to
the active unit. The PBUS access on the standby unit is disabled. Both units
must have a connection between their STM-4 or STM-1 front interfaces (opti-
cal or electrical cable).
In case of a failure on the active (working or protecting) unit the AU-4 cross
connect function on the active unit is reconfigured to loop the VC-12 signals
towards the front interfaces and to disable the PBUS access. The AU-4
cross connect on the standby unit is reconfigured to forward the VC-12 sig-
nals to the PBUS and to enable the PBUS access. With that the active unit
becomes the standby unit and vice versa.
FOX61xSAMO1 85
FUNCTIONAL DESCRIPTION
STM-4 STM-4
west STM-4 east
TUG-2 TUG-2
TU-12 TU-12
VC-12 VC-12
C-12 C-12
SAMO1 SAMO1
P12 P12
active standby highZ
PBUS
The Ethernet traffic accessing the Ethernet front ports is protected as fol-
lows: During normal operation, the EoS VC-4, VC-3, and VC-12 traffic on the
active unit (working or protecting) accesses the Ethernet front ports, while
the EoS VC-4, VC-3, and VC-12 traffic on the standby unit (protecting or
working) is looped towards the SDH front interfaces and then forwarded to
the active unit. The Ethernet front ports on the standby unit remain active,
but the forwarding of packets is disabled. Both units must have a connection
between their STM-4 or STM-1 front interfaces (optical or electrical cable).
In case of a failure on the active (working or protecting) unit the AU-4 cross
connect function on the active unit is reconfigured to loop the EoS VC-4, VC-
3, and VC-12 signals towards the SDH front ports and to disable the packet
forwarding to/from the Ethernet front ports. The AU-4 cross connect on the
standby unit is reconfigured to forward the EoS VC-4, VC-3, and VC-12 sig-
nals towards the Ethernet front ports and to enable the packet forwarding.
With that the active unit becomes the standby unit and vice versa.
86 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
STM-4 STM-4
west STM-4 east
AU-4 AU-4
MON MON
Cross Cross
Connect Connect
VC-4 VC-4
GFP GFP
MAC MAC
SAMO1 SAMO1
active ETH standby ETH
Please note:
Both Ethernet ports of the working and the protecting unit can be connected
to the same Ethernet switch.
→ STP is not required since the Ethernet port on the standby unit is not
in the forwarding state.
Please note:
During a protection switching event the user traffic is interrupted for up to
10 s.
To enable equipment protection for the SAMO1 unit some prerequisites must
be met:
• The protecting SAMO1 unit must be in the unassigned state. Otherwise
the unit will not be selectable in the EQP configuration in AP: /unit-x, Con-
figuration - EQP: Create Group…, EQP Group Creation, Protecting Unit.
• The protecting unit must be hardware compatible with the working unit.
Check the hardware compatibility status after the EQP group configura-
tion in the AP: /unit-x, Status - EQP: Units Status, HW Compatible.
• The protecting unit must be software compatible with the working unit.
Check the software compatibility status after the EQP group configuration
in the AP: /unit-x, Status - EQP: Units Status, SW Compatible.
The compatible software must be installed on the SAMO1 unit before the
EQP group creation.
FOX61xSAMO1 87
FUNCTIONAL DESCRIPTION
Please note:
The ports for the east and west uplink connections can use the same port
mode or different port modes.
→ Both STM-1 or STM-4, or mixed STM-1 and STM-4.
Please note:
The bypass connection through the AU-4 cross connect on the standby unit
is established automatically by the network element with four bidirectional
VC-4 connections (both ports use the STM-4 port mode) or with one bidirec-
tional VC-4 connection (at least one port uses the STM-1 port mode). VC-4
without a connection are “unequipped”.
The working SAMO1 unit of an EQP group is assigned and configured the
same way as a stand alone SAMO1 unit.
The protecting SAMO1 unit is running with the same ESW as the working
unit and must be in the unassigned state.
88 FOX61xSAMO1
FUNCTIONAL DESCRIPTION
Please note:
The cross connections on the SAMO1 unit always use the MO addresses of
the working unit.
→ When creating a cross connection you have to modify the copied MO
addresses taken from the protecting unit.
The unit status of the working and protecting units shows the actual status of
the units belonging to the equipment protection group. The unit status offers
also the commands for the EQP manipulation:
• Manual switch
The currently standby unit is set as active unit and the currently active
unit is set as standby unit. This requires that the currently standby unit is
in operational state, i.e.
− has no failure,
− is not isolated.
A manual switch is possible if it is indicated with the “Manual Switch-Over
Allowed” parameter.
Note that this command can only be activated on the working unit status
dialogue.
• Forced switch
The currently standby unit is set as active unit, independent of the opera-
tional state of the currently standby unit.
Note that there is a risk that the user traffic will be permanently inter-
rupted if the currently standby unit is not operational.
The currently active unit is set as standby unit.
Note that this command can only be activated on the working unit status
dialogue.
• Isolate unit
To be able to perform a maintenance action, e.g. update of the embed-
ded software, on an active unit without activating a protection switchover,
the working unit can be isolated. This means that the protection switching
state machine is frozen and no protection switch will be done until the iso-
lation of the unit is removed.
FOX61xSAMO1 89
FUNCTIONAL DESCRIPTION
Note that the isolate unit command can only be applied to the working
unit.
• Join unit
Remove the isolation of a previously isolated unit.
Note that the join unit command can only be applied to the working unit.
The table in the EQP status dialogue displays the following items:
• Unit
MO address of the unit belonging to the EQP group.
• EQP unit mode
The working unit is the unit where the protection group has been config-
ured.
The protecting unit is the unit that has been set to the unassigned state
before configuring the protection group.
• Active
Active true means the unit is the active unit, i.e. it is the operational unit.
Active false means the unit is the standby unit, i.e. it is not the operational
unit.
The active state can be changed with the “Manual Switch” and “Forced
Switch” commands.
• Failure
Failure true means the unit is in a failure state.
Failure false means the unit is not in a failure state.
The failure state can not be changed manually.
• Substituted
Substituted true on the working unit means the unit has been substituted
by the protecting unit. A substituted unit is also in the “active false” state.
Substituted false on the working unit means the unit has not been substi-
tuted, i.e. it is the active unit or it has been isolated.
The substituted state of the protecting unit is always false.
• Isolated
Isolated true means the unit has been isolated with the “Isolate Unit”
command.
Isolated false means the unit is not isolated.
The isolation state can be changed with the “Isolate Unit” and “Join Unit”
commands.
The isolated state of the protecting unit is always false.
• HW Compatible
HW compatible true means the working HW unit is compatible with the
protecting HW unit.
HW compatible false means the working HW unit is not compatible with
the protecting HW unit. Equipment protection is not possible.
• SW Compatible
SW compatible true means the working unit embedded software (ESW) is
compatible with the protecting unit ESW.
SW compatible false means the working unit ESW is not compatible with
the protecting unit ESW. Equipment protection is not possible.
• DB Saved
DB saved true means the current configuration of the working unit has
been saved to the FOX internal database.
DB saved false means the current configuration of the working unit has
not been saved to the FOX internal database. A protection switching
event will load an outdated configuration and traffic will be disturbed.
90 FOX61xSAMO1
COMMISSIONING
6 Commissioning
In this section, you will find the following information:
• Overview of the available cross connection on the SAMO1 unit (section
Cross connections (page 91)).
• Parameters for the SNCP configuration (section SNCP configuration
(page 106)).
• Handling and usage of the SAMO1 internal SDH resources (section
Resource usage strategy (page 107)).
• Automatic laser shutdown and restart (section Automatic laser shutdown
and restart (page 108)).
• Commissioning example of the SAMO1 unit for the transport of PDH and
Ethernet traffic (section Commissioning example of PDH and EoS trans-
port (page 110)).
Please refer to 1KHW002466 FOXCST Operationfor details on the general
GUI aspects, and refer to 1KHW002464 FOX61x System Description for
specific characteristics of the FOX.
The SAMO1 unit implements two cross connect functions, an AU-4 cross
connect and a TU-3/TU-12 cross connect. All signals that are cross con-
nected through the SAMO1 unit must pass either the AU-4 cross connect or
the AU-4 and TU-3/TU-12 cross connects.
Accordingly only traffic signal cross connections on the VC-4 layer can be
configured in a single step. Traffic signal cross connections on the VC-3 and
VC-12 layers are configured in two steps, cross connections on the P12 and
P0-nc layers must be configured in three steps.
An exception is the DCC which can be cross connected in one step to a
channel on a TDM service unit.
FOX61xSAMO1 91
COMMISSIONING
1. step
VC3/12
klm-xyz
2. step
P12
chan-x
PBUS 3. step
TDM
service P12 P12
unit chan-x chan-x
The figure below shows all cross connections on the SAMO1 unit. These
cross connections are described in detail in the following sections.
92 FOX61xSAMO1
COMMISSIONING
port-x/dcc ↔
port-x/j-x ↔ port-x/dcc ↔ TDM service unit/chan-y
port-y/j-y port-y/dcc
VC3 VC12
klm-x00 klm-xyz
Ethernet port
vc4/vc4-x/klm-x00 ↔ vc4/vc4-x/klm-xyz ↔
vc4/vc4-x/klm-x00 ↔ vc4/vc4-y/klm-y00 vc4/vc4-y/klm-abc
port-y/eos /vc3-y
pdh VC12
pdh VC12
Ethernet port vc12-y vc12-y
P12 P0_nc
vc4/vc4-x/klm-xyz ↔ chan-x chan-x
port-y/eos /vc12-y
Please note:
In the figure above all items “port-y/eos” are used in the same way also with
the internal Ethernet ports, i.e. with “internalPorts/port-z/eos”.
Please note:
In the figure above all items “Ethernet port” are used in the same way also
with the internal Ethernet ports, i.e. with “internalPorts/port-z”.
FOX61xSAMO1 93
COMMISSIONING
Please note:
In all figures and all tables of this section the numbering of the ports, SDH,
PDH and Ethernet signals uses the same characters on both sides of a con-
nection.
Despite of this the numbering needs not to be identical, e.g. a VC-12 signal
designated “vc4/vc4-1/klm-121” can be cross connected to another VC-12
signal designated “vc4/vc4-5/klm-372”.
Please note:
IThe sum of the /unit-x/vc4/vc4-y, /unit-x/port-y/eos/vc4-z and /unit-x/internal-
Ports/port-y/eos/vc4-z is in maximum 8.
94 FOX61xSAMO1
COMMISSIONING
port-1 port-1 port-1 port-1 port-2 port-2 port-2 port-2 port-3 port-4
(STM-4) (STM-4) (STM-4) (STM-4) (STM-4) (STM-4) (STM-4) (STM-4) (STM-1) (STM-1)
j-1 j-2 j-3 j-4 j-1 j-2 j-3 j-4 j-1 j-1
port-x/j-x ↔
port-x/j-x ↔ port-x/j-x ↔
port-y/j-y
port-y/eos /vc4-y vc4/vc4-y
FOX61xSAMO1 95
COMMISSIONING
Please note:
In the tables above all items “/port-x/eos” are used in the same way also with
the internal Ethernet ports, i.e. with “/internalPorts/port-x/eos”.
96 FOX61xSAMO1
COMMISSIONING
vc4/vc4-x/klm-x00 ↔
vc4/vc4-x/klm-x00 ↔ port-y/eos /vc3-y
vc4/vc4-y/klm-y00
FOX61xSAMO1 97
COMMISSIONING
Please note:
The working and the protecting path of an SNC protected connection must
be located on the same SAMO1 unit.
Please note:
In the tables above all items “/port-x/eos” are used in the same way also with
the internal Ethernet ports, i.e. with “/internalPorts/port-x/eos”.
98 FOX61xSAMO1
COMMISSIONING
vc4/vc4-x/klm-xyz ↔ vc4/vc4-x/klm-xyz ↔
port-y/eos /vc12-y vc4/vc4-x/klm-xyz ↔ pdh /vc12-y
vc4/vc4-y/klm-abc
port-y/eos port-y/eos
vc12-99 vc12-100
FOX61xSAMO1 99
COMMISSIONING
Please note:
The working and the protecting path of an SNC protected connection must
be located on the same SAMO1 unit.
100 FOX61xSAMO1
COMMISSIONING
Please note:
In the tables above all items “/port-x/eos” are used in the same way also with
the internal Ethernet ports, i.e. with “/internalPorts/port-x/eos”.
pdh/vc12-x/p12/chan -x ↔
pdh/vc12-x/p12/chan-x ↔ TDM service unit/chan-y
pdh/vc12-y/p12/chan-y
PBUS Access
FOX61xSAMO1 101
COMMISSIONING
For more information about the P12 connection termination points and the
P12 cross connection configuration refer to 1KHW002467 FOX61x TDM
Services.
102 FOX61xSAMO1
COMMISSIONING
dcc are all concatenated timeslots with n=3 (RS DCC) or n=9 (MS DCC).
port-1 port-2
dcc dcc
FOX61xSAMO1 103
COMMISSIONING
For more information about the P0-nc connection termination points and the
P0-nc cross connection configuration refer to 1KHW002467 FOX61x TDM
Services.
104 FOX61xSAMO1
COMMISSIONING
FOX61xSAMO1 105
COMMISSIONING
failed
OK
time
Protecting
channel
failed
OK
time
holdoff time guard time
Protection
switch
protecting
working
time
106 FOX61xSAMO1
COMMISSIONING
The SAMO1 has the following internal resources for the EoS application:
• 3 VC-4 which are used exclusively for VC-4 EoS members.
• 3 VC-4 equivalents which are used for VC-4 EoS members or VC-3 EoS
members.
• 2 VC-4 equivalents which are used for VC-4 EoS members or VC-12 EoS
members.
When allocating the internal resources to the VCG members during the
cross connect configuration, the resource manager handles the internal
resources for the EoS application according to the following strategy:
• EoS resource usage strategy set to VC3:
Take the required EoS VC-4 resources first from VC-4 resources, then
from VC-4/VC-3 resources and afterwards from VC-4/VC-12 resources
(shaded green in the table below).
• EoS resource usage strategy set to VC12:
Take the required EoS VC-4 resources first from VC-4 resources, then
from VC-4/VC-12 resources and afterwards from VC-4/VC-3 resources
(shaded yellow in the table below).
Example:
− The EoS resource usage strategy is VC3.
− The number of EoS VC-4 members is 6.
The resource handler will take all required resources from VC-4 and VC-4/
VC-3 resources. It will not be possible to configure any EoS VC-3 members.
Though it is still possible to configure EoS VC-12 members.
FOX61xSAMO1 107
COMMISSIONING
Please note:
By creating the EoS VC-3 members and EoS VC-12 members before creat-
ing the EoS VC-4 members, the resource handler will first allocate the
required resources for the EoS VC-3 and VC-12 members and take after-
wards all spare resources for the EoS VC-4 members.
→ The EoS resource usage strategy has no effect in this case.
Please note:
The SAMO1 supports the same parameters for SFP modules with optical
and electrical STM-1 interfaces. Accordingly the electrical STM-1 interface
supports also features that are normally only applicable for the optical inter-
face, such as laser shutdown and laser restart.
108 FOX61xSAMO1
COMMISSIONING
ALS enabled
Section in operation,
TX power on
no
yes
Automatic TX
power shutdown
FOX61xSAMO1 109
COMMISSIONING
TX power off
Delay
110 s
no Receive signal
from far end?
yes
Section in operation,
TX power on
6.5.1 Prerequisites
Before starting the commissioning of an SDH multiplexer for PDH and EoS
transport on the SAMO1 unit, the following prerequisites need to be fulfilled.
In a FOX, the SAMO1 service unit is inserted into one of the following slots:
− FOX615:
slot 1 … 10,
slot 12 … 21.
− FOX612:
slot 7… 10,
slot 12 … 14.
110 FOX61xSAMO1
COMMISSIONING
6.5.1.3 FOXCST
FOX61xSAMO1 111
COMMISSIONING
port-1 port-2
SDH SDH
sdh-1 sdh-2
vc4 vc4
vc4-1 vc4-2
vc4-1 vc4-1 vc4-1 vc4-1 vc4-1 vc4-1 vc4-2 vc4-2 vc4-2 vc4-2
klm100 klm200 klm311 klm312 klm313 klm321 klm111 klm112 klm113 klm121
PBUS
112 FOX61xSAMO1
COMMISSIONING
5. Execute “Apply”.
6. Navigate to the port-1 regenerator section configuration dialogue:
AP:/unit-19/port-1, Configuration - RS.
7. Disable the trail trace identifier supervision:
TTI Supervision = .
8. Navigate to the port-1 multiplex section configuration dialogue:
AP:/unit-19/port-1, Configuration - MS.
9. Enable the synchronisation status message:
SSM = .
10. Keep the default setting of the input mapping table for the quality levels:
The adapted QL equals the received QL.
11. Keep the default setting of the output mapping table for the quality levels:
The adapted QL equals the transmitted QL.
12. Set the synchronisation usability of all clock sources to “Do Not Use”:
<Source> = Do Not Use.
13. Navigate to the port-1 multiplex section protection configuration dialogue:
AP:/unit-19/port-1, Configuration - MSP.
14. Disable the multiplex section protection:
MSP Protection = .
15. Execute “Apply”.
16. Navigate to the port-1 DCC configuration dialogue:
AP:/unit-19/port-1, Configuration - DCC.
17. Disable the DCC usage:
DCC Type = None.
18. Execute “Apply”.
The SDH port 1 is fully configured.
FOX61xSAMO1 113
COMMISSIONING
10. Keep the default setting of the input mapping table for the quality levels:
The adapted QL equals the received QL.
11. Keep the default setting of the output mapping table for the quality levels:
The adapted QL equals the transmitted QL.
12. Set the synchronisation usability of all clock sources to “Do Not Use”:
<Source> = Do Not Use.
13. Execute “Apply”.
14. Navigate to the port-2 multiplex section protection configuration dialogue:
AP:/unit-19/port-2, Configuration - MSP.
15. Disable the multiplex section protection:
MSP Protection = .
16. Execute “Apply”.
17. Navigate to the port-2 DCC configuration dialogue:
AP:/unit-19/port-2, Configuration - DCC.
18. Disable the DCC usage:
DCC Type = None.
19. Execute “Apply”.
The SDH port 2 is fully configured.
114 FOX61xSAMO1
COMMISSIONING
FOX61xSAMO1 115
COMMISSIONING
116 FOX61xSAMO1
COMMISSIONING
6. Execute “Apply”.
7. Navigate to the P12 configuration dialogue:
AP:/unit-19/pdh/vc12-3/p12, Configuration - General.
8. Configure the P12 termination mode:
Mode = Transparent.
9. Execute “Apply”.
10. Navigate to the P12 configuration dialogue:
AP:/unit-19/pdh/vc12-4/p12, Configuration - General.
11. Configure the P12 termination mode:
Mode = Transparent.
12. Execute “Apply”.
The four P12 signals are configured.
FOX61xSAMO1 117
COMMISSIONING
118 FOX61xSAMO1
COMMISSIONING
7. Execute “Create”.
The connection from the internal VC-4 with TUG-3 structure to the SDH
port-1 is created.
8. Select the “Cross connections” view of the FOXCST.
Click on the “Connection Wizard” button:
FOX61xSAMO1 119
COMMISSIONING
120 FOX61xSAMO1
COMMISSIONING
FOX61xSAMO1 121
COMMISSIONING
2. Execute “Apply”.
3. AP:/unit-19/port-2, Main - Admin And Oper Status:
Set the administrative status of the SDH port-2 to up:
State = Up.
4. Execute “Apply”.
5. AP:/unit-19/port-5, Main - Admin And Oper Status:
Set the administrative status of the Ethernet port-5 to up:
State = Up.
6. Execute “Apply”.
7. AP:/unit-19/port-6, Main - Admin And Oper Status:
Set the administrative status of the Ethernet port-6 to up:
State = Up.
8. Execute “Apply”.
All SDH and Ethernet ports on the SAMO1 unit have been activated.
122 FOX61xSAMO1
COMMISSIONING
6. Execute “Apply”.
7. AP:/unit-20/port-4, Main - Admin And Oper Status:
Set the administrative status of the E1 port-4 to up:
State = Up.
8. Execute “Apply”.
All E1 ports on the LEDE1 unit have been activated.
End of instruction
FOX61xSAMO1 123
COMMISSIONING
124 FOX61xSAMO1
OPERATION
7 Operation
This section describes the operation functions of the SAMO1 unit. You will
find the following information:
• Description of the optical indicators found on the SAMO1 unit front (sec-
tion Unit optical indicators (page 125)).
• Diagnostic loop availability and handling (section Loops (page 126)).
• Detection and evaluation of traffic signal defects on the SAMO1 unit (sec-
tion Detection of signal defects (page 128)).
• Trail trace identifier (TTI) availability and handling (section Trail trace
identifier (TTI) (page 129)).
• Generic maintenance functions of the unit (section Maintenance
(page 130)).
Please note:
The operation functions described in this section assume a correctly config-
ured and operational SAMO1 unit.
LEDs on the front of the SAMO1 unit are used to indicate to the operator the
alarm status summary of the unit and of the network traffic signals.
XXXXx R1B
ANR_37900374
UNIT TRAFFIC
FOX61xSAMO1 125
OPERATION
7.2 Loops
7.2.1 VC loops
There are no dedicated maintenance functions available for the application
of VC-4, VC-3 or VC-12 loops on SAMO1.
To apply a loop on a VC, a unidirectional cross connection must be config-
ured on the desired path itself.
Please note:
Only the unidirectional cross connections for the front to front loops are
applicable.
Please note:
Loops activated with a unidirectional cross connection generate no “mainte-
nance function active” alarm as regular test loops would do.
SDH
access
network
SAMO1
STM-4
Front to Front
AU-4 or TU-3 loop
or TU-12
cross connect Back to Back
loop
126 FOX61xSAMO1
OPERATION
a. This loop requires the corresponding cross connections on the VC-4 layer.
SDH
access
network
SAMO1
STM-4
Front to Front
loop
Back to Back
loop
PBUS
FOX61xSAMO1 127
OPERATION
Please note:
Activated loops generate the “maintenance function active (MFA)” alarm.
Please note:
P12 loops are not treated as configuration parameters and are not stored in
the configuration. They are permanent until they are deactivated manually or
by a unit restart or by a power reset.
It is also possible to apply P12 and P0-nc loops with unidirectional cross
connections.
Please note:
Only the unidirectional cross connections for the front to front loops are
applicable.
a. This loop requires the corresponding cross connections on the VC-4 and VC-12 lay-
ers.
Bit or block errors in a signal are detectable by checking the signal's associ-
ated error detection code (EDC). An example of the EDC is the SDH BIP-N
(bit interleaved parity of level N).
The procedure to set and clear a degraded defect is as follows:
• Once every second, the number of bit or block errors (EDC) is compared
with the threshold DEGTHR.
− The second is declared as “bad”, if the number of errors is at least the
threshold value.
− The second is declared as “good”, if the number of errors is below the
threshold value.
• The degraded signal defect is set if DEGM consecutive bad seconds
have occurred.
• The degraded signal defect is cleared if DEGM consecutive good sec-
onds have occurred.
SAMO1 offers the evaluation of the degraded defect on the following layers:
− MS4
− MS1
− VC-4
− VC-3
− VC-12
128 FOX61xSAMO1
OPERATION
The trail trace identifier (TTI) is a means to identify each direction of a bidi-
rectional path. A wrong cross connection of the path within the network is
detected and generates an alarm.
• At the transmit side, the configured “Transmitted TTI” string is inserted
into the TTI byte.
• At the receive side, the received TTI is extracted from the TTI byte. The
received TTI is then compared with the configured “Expected TTI” for that
signal.
• If the received TTI and the configured “Expected TTI” are not the same,
the trace identifier mismatch (TIM) alarm indicates a wrong connection
somewhere in the network.
FOX61xSAMO1 129
OPERATION
SDH
access
network
SAMO1
SAMO1
STM-4 STM-4
Compare Alarm
Expected TTI
Please note:
In accordance to the ITU-T-recommendation, the TTI always requires all the
15 characters. If a TTI is not completely defined, the SAMO1 will supplement
“SPACE” characters up to a total of 15 characters.
7.5 Maintenance
130 FOX61xSAMO1
OPERATION
ESW upgrade procedure 1 The following procedure provides the upgrade process with one traffic inter-
ruption of about 1 s.
Please note:
A typical ESW upgrade will interrupt the traffic only for a short duration as
indicated above, or work completely hitless. In cases the ESW upgrade
includes a change in the programmable logic circuits on the unit the traffic
can be interrupted for a much longer time, i.e. up to 90 s.
→ In this case the ESW upgrade procedure 2 should be used.
FOX61xSAMO1 131
OPERATION
132 FOX61xSAMO1
OPERATION
Manual switch to protecting 1. Perform a manual switch-over from the working to the protecting SAMO1
unit unit:
AP: /unit-19, Status - EQP
Execute the “Manual Switch-Over” command.
Traffic will be switched to the protecting unit.
Traffic will be interrupted for up to 10 s.
ESW upgrade on the working 1. Apply the new ESW on the working SAMO1 unit:
unit AP: /unit-19, Main - Software
Select the downloaded software in the “Software” selection box.
Execute the “Apply” command.
2. Save the configuration:
Execute the “Save to NE” command.
3. Start the new ESW on the working SAMO1 unit:
AP: /unit-19, Main - Software
Execute the “Start Software” command.
The new ESW becomes active on the working unit.
4. Wait until the working unit has rebooted (about 90 s).
Manual switch to working unit 1. Perform a manual switch-over from the protecting to the working SAMO1
unit:
AP: /unit-19, Status - EQP
Execute the “Manual Switch-Over” command.
Traffic will be switched to the working unit.
Traffic will be interrupted for up to 10 s.
The ESW upgrade is complete.
End of instruction
FOX61xSAMO1 133
OPERATION
134 FOX61xSAMO1
FOXCST REFERENCE
8 FOXCST reference
This section gives a complete reference of the managed objects, properties,
and commands of the SAMO1 functional unit of the FOX.
In this section, you will find the following information:
• An introduction (section Introduction (page 135)),
• Management commands and parameters for all available access points
(AP), starting with the unit AP (section AP: / unit-x: SAMO1 (page 139)),
For a description on how to configure and bring into operation the SAMO1
unit and its main functions, please refer to section Commissioning (page 91).
8.1 Introduction
Below, you will find a detailed description of all the configuration parameters
and operations belonging to the managed objects model (MOM) for the
SAMO1 functional unit.
Figure 66 shows the access point (AP) tree for the SAMO1 unit with its man-
aged objects.
FOX61xSAMO1 135
FOXCST REFERENCE
<ap >
FOX
8 <ap>
port-y
0…1 <ap > 0...63 <ap> 0...9 <ap > 0...8 <ap>
nimp vc12-d vc3-e vc4-f
1 <ap>
internalPorts
2 <ap>
port-z
1 <ap>
vc4
0 ...8 <ap>
vc4-b
0… 1 <ap >
nimp
67 <ap>
vc12-c
1 <ap >
p12
Please note:
The managed objects “nimp” will be available in a future release.
With these managed objects (MOs) the following functions are covered:
136 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 137
FOXCST REFERENCE
Please note:
For better legibility of numbers in this user guide, inverted commas are used
when the number’s size exceeds three digits (e.g. 40’000). In parameter
entry fields of the FOXCST, these inverted commas must not be entered.
Instead, the numbers are entered without these inverted commas (e.g.
40000).
Please note:
Screenshots presented in this reference are examples and show configura-
tions or data that may not correspond to the view you see when managing
your FOX equipment.
138 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 139
FOXCST REFERENCE
140 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 141
FOXCST REFERENCE
142 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 143
FOXCST REFERENCE
144 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 145
FOXCST REFERENCE
146 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 147
FOXCST REFERENCE
Please note:
The creation and deletion of an EQP group must be done on the working
unit.
148 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 149
FOXCST REFERENCE
150 FOX61xSAMO1
FOXCST REFERENCE
Please note:
Automatic, manual and forced protection switching is available from the
working to the protecting unit and vice versa.
→ Please refer to section Equipment protection (EQP) (page 85).
FOX61xSAMO1 151
FOXCST REFERENCE
152 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 153
FOXCST REFERENCE
154 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 155
FOXCST REFERENCE
156 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 157
FOXCST REFERENCE
158 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 159
FOXCST REFERENCE
Isolated The working unit has been isolated with the “Iso-
late Unit” command.
160 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 161
FOXCST REFERENCE
8.4.2.2 AP: / unit-x / pdh / vc12-y, Main - Admin And Oper Status
Table 54: AP: / unit-x / pdh / vc12-y, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Administrative Sta- State Up Set the IETF administrative status of the VC-12
tus signal.
Down
Operational Status State Up Display of the IETF operational status of the VC-
12 signal.
Down
Testing
Unknown
Dormant
Not Present
Lower Layer Down
162 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 163
FOXCST REFERENCE
164 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 165
FOXCST REFERENCE
166 FOX61xSAMO1
FOXCST REFERENCE
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
FOX61xSAMO1 167
FOXCST REFERENCE
168 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 169
FOXCST REFERENCE
170 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 171
FOXCST REFERENCE
8.5.2.2 AP: / unit-x / pdh / vc12-y / p12, Main - Admin And Oper Status
Table 63: AP: / unit-x / pdh / vc12-y / p12, Main - Admin And Oper
Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the P12
signal.
Down
The operational status is set to up when the
Testing administrative status of the VC-12 is set to up
Unknown and no major defect is active.
Dormant
Not Present
Lower Layer Down
Please note that the fields for some of the configuration parameters are con-
text sensitive. Configuration parameters that are not available due to a
higher-ranking configuration parameter are indicated as “NA” (not available)
or “None”.
The steering parameters for the port configuration are
• Termination Mode
• Synchronization Method
The configuration strategy to be followed is from the uppermost tab (Gen-
eral) to the lowermost tab (Channel), and on the tabs from the top parameter
downwards.
After the parameter configuration of a higher-ranking parameter press the
“Apply” button to assign the applicable values to the lower-ranking parame-
ters.
172 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 173
FOXCST REFERENCE
SSI-Sa5 Use the Sa5 bit in time slot 0 for the transport of
the synchronization status indication (SSI).
The SSI method is ABB proprietary and is com-
patible with the FOX51x.
This parameter value is only available with the
termination modes “PCM30”, “PCM30C”,
“PCM31” and “PCM31C”.
QL Transmission Source ESI-1 Synchronization sources are all the PDH clock
ESI-2 sources as they are configured at the AP: /Con-
figuration - PETS
<PDH Clock Source 1>
<PDH Clock Source 2>
<PDH Clock Source 3>
<PDH Clock Source 4>
Internal
Usage NA No synchronization method has been
CanBeUsed Transmit the QL value of the selected synchroni-
zation source
DoNotUse Transmit the QL value 15, i.e. indicating that the
traffic signal cannot be used as a synchroniza-
tion source.
174 FOX61xSAMO1
FOXCST REFERENCE
Please note:
For more information regarding quality level handling please refer to
1KHW002467 FOX61x TDM Services.
FOX61xSAMO1 175
FOXCST REFERENCE
176 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 177
FOXCST REFERENCE
Table 67: AP: / unit-x / pdh / vc12-y / p12, Fault Management (contin-
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
NCI Non CRC4 Interworking Communica- Warning The CRC4 monitoring function is disa-
tion Alarm bled due to a disabled CRC4 function at
the remote equipment.
RDI Remote Defect Indica- Communica- Minor The far end equipment has one or more
tion tion Alarm of the following defects:
Hardware fault, AIS received, BER
> 10-3, loss of frame, loss of signal.
RLOCM Remote Loss Of CAS Communica- Minor Loss of CAS multiframe alignment on the
MF tion Alarm incoming P12 signal at the remote equip-
ment.
RNCI Remote Non CRC4 Communica- Minor “Non CRC4 interworking” alarm at the
Interworking tion Alarm remote equipment.
NDPF Near End Degraded Communica- Warning ES ≥ 432 or SES ≥ 22 over a 24 hour
Performance tion Alarm interval at the near end.
The alarm status is reset after a 24 hour
interval with ES = 0 and SES = 0.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
NUPF Near End Unacceptable Communica- Warning ES ≥ 150 or SES ≥ 15 over a 15 min.
Performance tion Alarm interval at the near end.
The alarm status is reset after a 15 min.
interval with ES ≤ 3 and SES = 0.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
FDPF Far End Degraded Per- Communica- Warning ES ≥ 432 or SES ≥ 22 over a 24 hour
formance tion Alarm interval at the near end.
The alarm status is reset after a 24 hour
interval with ES = 0 and SES = 0.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
FUPF Far End Unacceptable Communica- Warning ES ≥ 150 or SES ≥ 15 over a 15 min.
Performance tion Alarm interval at the near end.
The alarm status is reset after a 15 min.
interval with ES ≤ 3 and SES = 0.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
178 FOX61xSAMO1
FOXCST REFERENCE
8.5.5.2 AP: / unit-x / pdh / vc12-y / p12, Performance Management - P12 Events
FOX61xSAMO1 179
FOXCST REFERENCE
Please note:
During maintenance an NCI Alarm (non-CRC4 interworking) can appear. If
this alarm is active, and it is known that the other equipment now sends the
CRC4 multiframe, the following procedure can clear the alarm:
→ Perform a “Force new search” in the CRC4 MFA status of the P12
layer, or
→ Disable CRC4 and re-enable the CRC4.
180 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 181
FOXCST REFERENCE
8.6.2.2 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Main - Admin And Oper Status
Table 73: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Main - Admin And
Oper Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the
channel.
Down
The operational state is set to up when the chan-
Testing nel has a sink connection configured and no
Unknown defect is active on the received signal from the
PBUS.
Dormant
Not Present
Lower Layer Down
Please note:
All layer rate, number of time slots and time slot allocation parameters are
read only.
→ To change a parameter the channel has to be deleted and newly cre-
ated with the modified parameters.
182 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 183
FOXCST REFERENCE
Please note:
The z-End of a protected connection shows two entries in the “Connected to
CTPs” table, one for the working and one for the protecting path.
Table 75: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Fault Management
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
MFA Maintenance Function Communica- Warning This alarm appears if a manual change
Active tion Alarm in the status/maintenance function has
been done. E.g. manual switching
request.
TSF Trail Signal Failure Communica- Major For unprotected connections: Signal fail-
tion Alarm ure on the working channel subnetwork
connection.
For protected connections: Signal failure
on the working and protecting channel
subnetwork connection.
Alarm activation criteria: Server signal
fail or CAS AIS.
Note that this alarm is not monitored by
default.
RTSF Redundant Trail Signal Communica- Minor For unprotected connections: Alarm not
Failure tion Alarm available.
For protected connections: Signal failure
on the working or protecting channel
subnetwork connection.
Alarm activation criteria: Server signal
fail or CAS AIS.
Note that this alarm is not monitored by
default.
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
184 FOX61xSAMO1
FOXCST REFERENCE
8.6.5.1 AP: / unit-x / pdh / vc12-y / p12 / chan-z, Performance Management - Protection
FOX61xSAMO1 185
FOXCST REFERENCE
Table 79: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status - CTP
Operation Name Parameter Name Range Description / Details
Trail Status Working Trail, <MO Address> Managed object address of the CTP (connec-
Remote CTP tion termination point) where the P12 or P0-nc
signal is connected to, e.g. /unit-21/port-1/chan-
1.
Working Trail, Sta- OK No failure on the received signal.
tus Signal Fail status on the received signal.
SF
CAS AIS CAS AIS status in the received signal, i.e. an all
‘1’ signal in time slot 16.
SD Signal Degraded status on the received signal.
Not Available The status of the received signal is not available,
e.g. when the CTPs role is a-End in a unidirec-
tional connection.
Protecting Trail, <MO Address> Managed object address of the CTP (connec-
Remote CTP tion termination point) where the P12 or P0-nc
signal is connected to, e.g. /unit-21/port-2/chan-
1.
Protecting Trail, OK No failure on the received signal.
Status Signal Fail status on the received signal.
SF
CAS AIS CAS AIS status in the received signal, i.e. an all
‘1’ signal in time slot 16.
SD Signal Degraded status on the received signal.
Not Available The status of the received signal is not available,
e.g. when the CTPs role is a-End in a unidirec-
tional connection.
186 FOX61xSAMO1
FOXCST REFERENCE
Table 79: AP: / unit-x / pdh / vc12-y / p12 / chan-z, Status - CTP (con-
Operation Name Parameter Name Range Description / Details
Active Trail Working The trail from the a-End working remote CTP
has been selected.
Protecting The trail from the a-End protecting remote CTP
has been selected.
Not Available There is no active trail.
Protecting/Wait-To-Restore In case of revertive protection switching the
selector is waiting to switch back to the restored
a-End working remote CTP.
External Request Request Release Automatic trail selection.
Force Working Force the selector to use the trail from the a-End
working remote CTP.
Force Protecting Force the selector to use the trail from the a-End
protecting remote CTP.
Manual Working Prefer the trail from the a-End working remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the protecting trail.
Manual Protecting Prefer the trail from the a-End protecting remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the working trail.
FOX61xSAMO1 187
FOXCST REFERENCE
Table 80: AP: / unit-x / port-y, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Administrative Sta- State Up Set the IETF administrative status of the SDH
tus port.
Down
Unused ports (without fibres or electrical cables
connected to them) should be set to the down
state, so that they do not generate alarms (i.e.
loss of signal).
Operational Status State Up Display of the IETF operational status of the
SDH port.
Down
Testing
Unknown
Dormant
Not Present
Lower Layer Down
188 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 189
FOXCST REFERENCE
190 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 191
FOXCST REFERENCE
192 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 193
FOXCST REFERENCE
194 FOX61xSAMO1
FOXCST REFERENCE
Please note:
In an MSP protected path the DCC is not protected.
→ The DCC configuration and cross connection must be done on the
working and on the protecting section. The selection of the active sec-
tion must be handled by the management communication network.
Please note:
A DCC cannot be used as a-End in a protected connection.
FOX61xSAMO1 195
FOXCST REFERENCE
196 FOX61xSAMO1
FOXCST REFERENCE
a. The support of this alarm is only possible for SFP modules with diagnostics func-
tion. SFP modules with electrical interfaces do not support this alarm (no diagnos-
tics function available).
Please note:
The degraded signal and performance alarm thresholds are the same for
MS4 and MS1.
FOX61xSAMO1 197
FOXCST REFERENCE
Please note:
SAMO1 supports laser restart for SFP modules with optical and electrical
interfaces.
→ The laser restart function is also applied to the electrical interface.
198 FOX61xSAMO1
FOXCST REFERENCE
Please note:
SAMO1 supports diagnostics for SFP modules. Support of diagnostics is not
mandatory for SFP modules with optical interfaces. However ABB recom-
mends only optical SFP modules that support diagnostics.
SFP modules with the electrical STM-1 interface do not support diagnostics.
FOX61xSAMO1 199
FOXCST REFERENCE
200 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 201
FOXCST REFERENCE
202 FOX61xSAMO1
FOXCST REFERENCE
Please note:
The MSP status is available only on the working ports, i.e on port-1 and
port-3.
Please note:
MSP with SAMO1 provides non revertive protection switching, i.e. if after a
protection switching to the protecting channel the working channel is opera-
tional again, there is no automatic switching back to the working channel.
→ The switching back must be ordered by an external command (manual
switch or forced switch).
FOX61xSAMO1 203
FOXCST REFERENCE
Table 96: AP: / unit-x / port-y, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Administrative Sta- State Up Set the IETF administrative status of the Ether-
tus net port.
Down
Operational Status State Up Display of the IETF operational status of the
Ethernet port.
Down
Testing
Unknown
Dormant
Not Present
Lower Layer Down
204 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 205
FOXCST REFERENCE
206 FOX61xSAMO1
FOXCST REFERENCE
Please note:
The link pass through feature must be enabled on the Ethernet interfaces at
both sides of the SDH path to become operational.
FOX61xSAMO1 207
FOXCST REFERENCE
Please note:
The administrative state of the Ethernet port must be up to get the perfor-
mance management counters.
208 FOX61xSAMO1
FOXCST REFERENCE
8.9.2.2 AP: / unit-x / port-y / dcc, Main - Admin And Oper Status
FOX61xSAMO1 209
FOXCST REFERENCE
Table 103: AP: / unit-x / port-y / dcc, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the
DCC signal.
Down
The operational state is up when the port admin-
Testing istrative state is up.
Unknown
Dormant
Not Present
Lower Layer Down
210 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 211
FOXCST REFERENCE
8.9.5.1 AP: / unit-x / port-y / dcc, Performance Management - MIB-2 Interface Table
212 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 213
FOXCST REFERENCE
214 FOX61xSAMO1
FOXCST REFERENCE
8.10.2.2 AP: / unit-x / port-y / j-z, Main - Admin And Oper Status
Table 110: AP: / unit-x / port-y / j-z, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the
AU-4 signal.
Down
The operational state is up when the port admin-
Testing istrative state is up and a sink connection to
Unknown another VC-4 resource is configured and no
major defect is active.
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 215
FOXCST REFERENCE
216 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 217
FOXCST REFERENCE
218 FOX61xSAMO1
FOXCST REFERENCE
8.11.2.2 AP: / unit-x / port-y / eos, Main - Admin And Oper Status
Table 114: AP: / unit-x / port-y / eos, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the eos
group.
Down
The operational state is up when the port admin-
Testing istrative state is up and no GFPLOF or
Unknown VCGLOTC defect is active.
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 219
FOXCST REFERENCE
220 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 221
FOXCST REFERENCE
8.11.5.1 AP: / unit-x / port-y / eos, Performance Management - EoS GFP Encapsulation
222 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 223
FOXCST REFERENCE
8.12.2.2 AP: / unit-x / port-y / eos / vcz-a, Main - Admin And Oper Status
Table 120: AP: / unit-x / port-y / eos / vcz-a, Main - Admin And Oper
Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the EoS
group member.
Down
The operational state is up when the port admin-
Testing istrative state is up.
Unknown VC-4 members of an EoS group require in addi-
tion a sink connection to another VC-4 resource.
Dormant
Not Present
Lower Layer Down
224 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 225
FOXCST REFERENCE
Please note:
The z-End of a protected connection shows two entries in the “Connected to
CTPs” table, one for the working and one for the protecting path.
226 FOX61xSAMO1
FOXCST REFERENCE
Table 122: AP: / unit-x / port-y / eos / vc4-a, Fault Management (contin-
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
TSF Trail Signal Failure Communica- Major For unprotected connections: Signal fail-
tion Alarm ure on the working VC-4 subnetwork
connection.
For protected connections: Signal failure
on the working and protecting VC-4 sub-
network connection.
Alarm activation criteria: AU-4-LOP, AU-
4-AIS, VC-4-UNEQ or VC-4-TIM.
Note that this alarm is not monitored by
default.
RTSF Redundant Trail Signal Communica- Minor For unprotected connections: Alarm not
Failure tion Alarm available.
For protected connections: Signal failure
on the working or protecting VC-4 sub-
network connection.
Alarm activation criteria: AU-4-LOP, AU-
4-AIS, VC-4-UNEQ or VC-4-TIM.
Note that this alarm is not monitored by
default.
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
FOX61xSAMO1 227
FOXCST REFERENCE
Table 123: AP: / unit-x / port-y / eos / vc3-a, Fault Management (contin-
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
FDPF Far End Degraded Per- Communica- Warning ES ≥ 2000 or SES ≥ 33 or BBE ≥ 6480
formance tion Alarm over a 24 hour interval at the far end
input signal.
The alarm status is reset after a 24 hour
interval with ES = 0 and SES = 0 and
BBE ≤ 270.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
FUPF Far End Unacceptable Communica- Warning ES ≥ 150 or SES ≥ 15 or BBE ≥ 1100
Performance tion Alarm over a 15 min. interval at the far end
input signal.
The alarm status is reset after a 15 min.
interval with ES ≤ 3 and SES = 0 and
BBE ≤ 50.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
DEG Degraded Signal Communica- Major DEGM consecutive bad seconds with at
tion Alarm least DEGTHR bad blocks per bad sec-
ond, configured for VC-3.
MFA Maintenance Function Communica- Warning This alarm appears if a manual change
Active tion Alarm in the status/maintenance function has
been done. E.g. applying a loop.
TSF Trail Signal Failure Communica- Major For unprotected connections: Signal fail-
tion Alarm ure on the working VC-3 subnetwork
connection.
For protected connections: Signal failure
on the working and protecting VC-3 sub-
network connection.
Alarm activation criteria: TU-3-LOP, TU-
3-AIS, VC-3-UNEQ or VC-3-TIM.
Note that this alarm is not monitored by
default.
RTSF Redundant Trail Signal Communica- Minor For unprotected connections: Alarm not
Failure tion Alarm available.
For protected connections: Signal failure
on the working or protecting VC-3 sub-
network connection.
Alarm activation criteria: TU-3-LOP, TU-
3-AIS, VC-3-UNEQ or VC-3-TIM.
Note that this alarm is not monitored by
default.
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
228 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 229
FOXCST REFERENCE
Table 124: AP: / unit-x / port-y / eos / vc12-a, Fault Management (con-
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
RTSF Redundant Trail Signal Communica- Minor For unprotected connections: Alarm not
Failure tion Alarm available.
For protected connections: Signal failure
on the working or protecting VC-12 sub-
network connection.
Alarm activation criteria: TU-12-LOP,
TU-12-AIS, VC-12-UNEQ or VC-12-TIM.
Note that this alarm is not monitored by
default.
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
230 FOX61xSAMO1
FOXCST REFERENCE
8.12.7.2 AP: / unit-x / port-y / eos / vcz-a, Performance Management - Unfiltered Events
FOX61xSAMO1 231
FOXCST REFERENCE
Table 128: AP: / unit-x / port-y / eos / vcz-a, Status - General (contin-
Operation Name Parameter Name Range Description / Details
Server Signal Sta- Server Signal State OK Failure indication of the VC-4, VC-3 or VC-12
tus server signal, i.e. the AU-4, TU-3 or TU-12 sig-
AU-AIS
nal.
TU-AIS
AU-LOP
TU-LOP
Signal Label GFP The VC-4, VC-3 and VC-12 layers are able to
transport a variety of client signals applied to the
Unequipped
layer via different adaptation functions. The infor-
<Any other signal label> mation about the signal type is carried in the
(trail) signal label, transported in the C2 byte of
the VC-4 or VC-3 path overhead or the V5 byte
of the VC-12 path overhead.
SAMO1 inserts the signal label “GFP” for all VC
signals used for Ethernet transport.
Signal Label State OK The received signal label equals the expected
signal label, i.e. “GFP”.
Mismatch The received signal label is not equal to the
expected signal label.
Not Checked The EoS VC is not cross connected.
RDI State The VC-4, VC-3 and VC-12 path remote defect
indication (RDI) displays the received RDI state
which is sent back from the far end termination
function, if either an AU-4, TU-3 or TU-12 server
signal failure or a trail signal failure is being
detected.
RDI is transported in the G1 byte of the VC-4 or
VC-3 path overhead or the V5 byte of the VC-12
path overhead. It can be “true” or “false”.
Note that the VC signal status is not filtered. E.g.
a TTI mismatch in the RS layer inserts an AIS as
a consequent action. All subsequent failures are
also displayed: Signal label mismatch.
Note that these states are not visible in the alarm
list since the alarms are filtered.
232 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 233
FOXCST REFERENCE
234 FOX61xSAMO1
FOXCST REFERENCE
The VC4 Overview presents some parameters of all available vc4 instances
in a condensed form.
FOX61xSAMO1 235
FOXCST REFERENCE
236 FOX61xSAMO1
FOXCST REFERENCE
8.14.2.2 AP: / unit-x / vc4 / vc4-b, Main - Admin And Oper Status
Table 133: AP: / unit-x / port-y, Main - Admin And Oper Status
Operation Name Parameter Name Range Description / Details
Administrative Sta- State Up Set the IETF administrative status of the VC-4.
tus Unused VC-4 (without cross connection) should
Down
be set to the down state, so that they do not gen-
erate alarms (i.e. unequipped).
Operational Status State Up Display of the IETF operational status of the
VC-4.
Down
Testing
Unknown
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 237
FOXCST REFERENCE
238 FOX61xSAMO1
FOXCST REFERENCE
Please note:
Changing the structure of a TUG-3 will delete all existing managed objects
(MO) of this TUG-3 and create the MOs according to the new TUG-3 struc-
ture.
FOX61xSAMO1 239
FOXCST REFERENCE
Please note:
The z-End of a protected connection shows two entries in the “Connected to
CTPs” table, one for the working and one for the protecting path.
240 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 241
FOXCST REFERENCE
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
242 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 243
FOXCST REFERENCE
244 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 245
FOXCST REFERENCE
8.15.2.2 AP: / unit-x / vc4 / vc4-b / klm-n00, Main - Admin And Oper Status
246 FOX61xSAMO1
FOXCST REFERENCE
Table 143: AP: / unit-x / vc4 / vc4-b / klm-n00, Main - Admin And Oper
Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the
VC-3.
Down
The operational state is up when the administra-
Testing tive state of the VC-4 is up and a sink connection
Unknown to another VC-3 resource is configured.
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 247
FOXCST REFERENCE
Please note:
The z-End of a protected connection shows two entries in the “Connected to
CTPs” table, one for the working and one for the protecting path.
248 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 249
FOXCST REFERENCE
Table 146: AP: / unit-x / vc4 / vc4-b / klm-n00, Status - CTP (continued)
Operation Name Parameter Name Range Description / Details
External Request Request Release Automatic trail selection.
Force Working Force the selector to use the trail from the a-End
working remote CTP.
Force Protecting Force the selector to use the trail from the a-End
protecting remote CTP.
Manual Working Prefer the trail from the a-End working remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the protecting trail.
Manual Protecting Prefer the trail from the a-End protecting remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the working trail.
8.16.2.2 AP: / unit-x / vc4 / vc4-b / klm-npq, Main - Admin And Oper Status
250 FOX61xSAMO1
FOXCST REFERENCE
Table 147: AP: / unit-x / vc4 / vc4-b / klm-npq, Main - Admin And Oper
Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the
VC-12.
Down
The operational state is up when the administra-
Testing tive state of the VC-4 is up and a sink connection
Unknown to another VC-12 resource is configured.
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 251
FOXCST REFERENCE
Please note:
The z-End of a protected connection shows two entries in the “Connected to
CTPs” table, one for the working and one for the protecting path.
252 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 253
FOXCST REFERENCE
Table 150: AP: / unit-x / vc4 / vc4-b / klm-npq, Status - CTP (continued)
Operation Name Parameter Name Range Description / Details
External Request Request Release Automatic trail selection.
Force Working Force the selector to use the trail from the a-End
working remote CTP.
Force Protecting Force the selector to use the trail from the a-End
protecting remote CTP.
Manual Working Prefer the trail from the a-End working remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the protecting trail.
Manual Protecting Prefer the trail from the a-End protecting remote
CTP. Use this trail only if the fault status is not
worse than the fault status of the working trail.
254 FOX61xSAMO1
FOXCST REFERENCE
8.18.2.2 AP: / unit-x / internalPorts / port-y, Main - Admin And Oper Status
Table 151: AP: / unit-x / internalPorts / port-y, Main - Admin And Oper
Status
Operation Name Parameter Name Range Description / Details
Administrative Sta- State Up Set the IETF administrative status of the internal
tus Ethernet port.
Down
Note that the usage of the internal Ethernet port
is configured with the parameter “Internal Port
Usage” on the unit configuration: unit-x. Configu-
ration - General - EoS Resource Usage.
Operational Status State Up Display of the IETF operational status of the
internal Ethernet port.
Down
Testing
Unknown
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 255
FOXCST REFERENCE
256 FOX61xSAMO1
FOXCST REFERENCE
Please note:
The link pass through feature must be enabled on the Ethernet interfaces at
both sides of the SDH path to become operational.
8.18.4.1 AP: / unit-x / internalPorts / port-y, Performance Management - MIB-2 Interface Table
FOX61xSAMO1 257
FOXCST REFERENCE
258 FOX61xSAMO1
FOXCST REFERENCE
8.19.2.2 AP: / unit-x / internalPorts / port-y / eos, Main - Admin And Oper Status
Table 157: AP: / unit-x / internalPorts / port-y / eos, Main - Admin And
Oper Status
Operation Name Parameter Name Range Description / Details
Operational Status State Up Display of the IETF operational status of the EoS
group.
Down
Testing
Unknown
Dormant
Not Present
Lower Layer Down
FOX61xSAMO1 259
FOXCST REFERENCE
260 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 261
FOXCST REFERENCE
8.19.5.1 AP: / unit-x / internalPorts / port-y / eos, Perf. Management - EoS GFP Encapsulation
262 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 263
FOXCST REFERENCE
8.20.2.2 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Main - Admin And Oper Status
264 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 265
FOXCST REFERENCE
Please note:
The z-End of a protected connection shows two entries in the “Connected to
CTPs” table, one for the working and one for the protecting path.
266 FOX61xSAMO1
FOXCST REFERENCE
Table 165: AP: / unit-x / internalPorts / port-y / eos / vc4-a, Fault Man-
agement (continued)
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
TSF Trail Signal Failure Communica- Major For unprotected connections: Signal fail-
tion Alarm ure on the working VC-4 subnetwork
connection.
For protected connections: Signal failure
on the working and protecting VC-4 sub-
network connection.
Alarm activation criteria: AU-4-LOP, AU-
4-AIS, VC-4-UNEQ or VC-4-TIM.
Note that this alarm is not monitored by
default.
RTSF Redundant Trail Signal Communica- Minor For unprotected connections: Alarm not
Failure tion Alarm available.
For protected connections: Signal failure
on the working or protecting VC-4 sub-
network connection.
Alarm activation criteria: AU-4-LOP, AU-
4-AIS, VC-4-UNEQ or VC-4-TIM.
Note that this alarm is not monitored by
default.
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
FOX61xSAMO1 267
FOXCST REFERENCE
Table 166: AP: / unit-x / internalPorts / port-y / eos / vc3-a, Fault Man-
agement (continued)
ID Fault Cause Event Type Traffic Default Description
Affecting Severity
FDPF Far End Degraded Per- Communica- Warning ES ≥ 2000 or SES ≥ 33 over a 24 hour
formance tion Alarm interval at the far end.
The alarm status is reset after a 24 hour
interval with ES = 0 and SES = 0.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
FUPF Far End Unacceptable Communica- Warning ES ≥ 150 or SES ≥ 15 over a 15 min.
Performance tion Alarm interval at the far end.
The alarm status is reset after a 15 min.
interval with ES 3 and SES = 0.
The alarm can be cleared by resetting
the corresponding PM alarm counter.
DEG Degraded Signal Communica- Major DEGM consecutive bad seconds with at
tion Alarm least DEGTHR bad blocks per bad sec-
ond, configured for VC-3.
MFA Maintenance Function Communica- Warning This alarm appears if a manual change
Active tion Alarm in the status/maintenance function has
been done. E.g. applying a loop.
TSF Trail Signal Failure Communica- Major For unprotected connections: Signal fail-
tion Alarm ure on the working VC-3 subnetwork
connection.
For protected connections: Signal failure
on the working and protecting VC-3 sub-
network connection.
Alarm activation criteria: TU-3-LOP, TU-
3-AIS, VC-3-UNEQ or VC-3-TIM.
Note that this alarm is not monitored by
default.
RTSF Redundant Trail Signal Communica- Minor For unprotected connections: Alarm not
Failure tion Alarm available.
For protected connections: Signal failure
on the working or protecting VC-3 sub-
network connection.
Alarm activation criteria: TU-3-LOP, TU-
3-AIS, VC-3-UNEQ or VC-3-TIM.
Note that this alarm is not monitored by
default.
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
268 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 269
FOXCST REFERENCE
Please note:
The monitoring of the TSF and RTSF alarms is disabled by default.
8.20.7.1 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Performance Management - G.826
8.20.7.2 AP: / unit-x / internalPorts / port-y / eos / vcx-a, Perf. Management - Unfiltered Events
270 FOX61xSAMO1
FOXCST REFERENCE
FOX61xSAMO1 271
FOXCST REFERENCE
272 FOX61xSAMO1
FOXCST REFERENCE
Table 172: AP: / unit-x / internalPorts / port-y / eos / vcz-a, Status - EoS
(continued)
Operation Name Parameter Name Range Description / Details
Tx State Operational When LCAS is enabled the transmitter state of
each member (VC-4, VC-3 or VC-12) of an EoS
group is displayed.
Operational indicates normal transmission.
Added This member is about to be added to the group.
Idle This member is not part of the group or about to
be removed.
Do Not Use Do not use the payload since the receive side
reported a failure
Fixed Non-LCAS LCAS is disabled.
Sequence Number 0 … 62 The sequence number uniquely identifies each
received member within an EoS group.
None The EoS group member is not operational.
FOX61xSAMO1 273
FOXCST REFERENCE
274 FOX61xSAMO1
ANNEX
9 Annex
9.1 Associated documents
FOX61xSAMO1 275
ANNEX
276 FOX61xSAMO1
Contact us
www.abb.com/utilitycommunication