Janakpur Agro Farm

Digester Tank Plate Load Test


Site Description

Name of the Company Janakpur Agro Farm Pvt. Ltd.


Name of the Farm Janakpur Agro Farm
Address & Location Murgiya, Dhanushadham - 9, Dhanusha,
Province 2
Total Land Area 74012.38 Sq.m.

Plate Load Test Co-ordinates

Site Condition
A Circular Digester of 26m dia. for storage of tons of chicken manure had to be built on top
of low bearing, silty clay soil upto 3m with coarse sand mix gravel and pebbles upto 12m
depth inside Janakpur Agro Farm. The water table was not found as per soil investigation
report.

Soil report is attached in zip file.

The bearing capacity of soil was very low, so Piled foundation was recommended by the
designer. Piled foundations would have served this purpose from a structural view point, but
construction was going to take much longer than the client was willing to tolerate.

As alternative to Piled foundation, Use of Geo-grid was recommended by Sanjay K. Jain


(Geotechnical Engineer).

Please refer to A Report on Enhanced Bearing Capacities of Using Geo Grid (Tencate 20050)
for Agro Farm Digestor Tank at Janakpur attached in zip file.

Use of TENCATE 200/50 Geo-grid was proposed but the cost was too high.

So, Cheaper PARALINK™ 300 basal reinforcement was used for reinforcing soil layer.
Soil Improvement Profile

Mat foundation PCC level

300mm gravel mix sand with compaction

 Layer – 1 (Paralink-300 Geogrid)

300mm gravel mix sand with compaction

Layer – 2 (Paralink-300 Geogrid)

300mm gravel mix sand with compaction

Original Ground