VERTICAL HORIZONTAL VERTICAL HORIZONTAL CORNER 'L'BARS


STEEL STEEL STEEL STEEL 'U' BAR CLOSER SAME SIZE AS
Min. T12 HORIZ. BARS IN WALL
TENSION 300
CORNER 'L'BARS ANCHORAGE Min.
SAME SIZE AS
HORIZ. BARS IN WALL MAINTENANCE/CLEANING/OPERATION.

VERTICAL HORIZONTAL
STEEL STEEL

50
VERTICAL HORIZONTAL DECOMMISSIONING/DEMOLITION.

Min.
306
STEEL STEEL 55 590
LAP
VERTICAL HORIZONTAL

LAP
STEEL

605
STEEL
HORIZONTAL
VERTICAL STEEL Notes
STEEL 1. ALL BUROHAPPOLD DRAWINGS ARE TO BE READ IN
IF H700, H12 LACERS
CONJUNCTION WITH THE GENERAL NOTES DRAWING No. S-0001.
AT 250 C/C
2. ALL BUROHAPPOLD DRAWINGS ARE TO BE READ IN
CONJUNCTION WITH THE RELEVANT BUROHAPPOLD
SPECIFICATION AND ALL RELEVANT ARCHITECTS AND SERVICE
ENGINEERS DRAWINGS AND SPECIFICATIONS.
TYPICAL VERTICALSECTION TYPICAL STARTER TYPICAL LAP DETAIL TYPICAL TOP OF TYPICAL TOP OF TYPICAL HORIZONTAL TYPICAL HORIZONTAL 3. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS STATED
SHOWING BAR DETAIL AT FLOOR LEVEL WALL DETAIL WALL DETAIL TEE JUNCTION DETAIL CORNER DETAILS OTHERWISE. ALL LEVELS ARE IN METRES AND RELATE TO
ORDNANCE DATUM.
SCALE 1:20 SCALE 1:20 SCALE 1:20 SCALE 1:20
ARRANGEMENT OF STEEL (INTO SLAB) (NO SLAB) 4. DO NOT SCALE FROM ANY DRAWING. WORK TO FIGURED
SCALE 1:20 SCALE 1:20 SCALE 1:20
DIMENSIONS ONLY. ANY DISCREPANCIES IN DIMENSIONS ARE TO
BE REFERRED TO THE DESIGNER BEFORE WORK IS PUT TO
HAND.

1T25 BAR-WALLS <250 THK.


2T2B BARS-WALLS>250 THK.
CENTRAL OVER OPENING

T10-200 Min.
DISTRIBUTION
STEEL

T16 TRIMMERS
NF & FF LAYERS VARIES MAXIMUM 1000mm
12No. H16 VERT. BARS T12-150 Min.
-WHEN GREATER THAN

500

400
PRIMARY STEEL 1000mm REINFORCE AS
H10 SHEAR LINKS@200mm C/C's STANDARD WALL DETAIL

X - X. 500
'U'BARS

X 300
T16 TRIMMERS
NF & FF LAYERS
PIER RC DETAIL Min.
IF H700, H12
SCALE 1:20
LACERS AT 250
C/CL

'U' BARS SAME SIZE


& CENTRES AS MAIN TYPICAL UPSTAND DETAIL
T16 DIAGONAL TRIMMERS VERTICAL STEEL SCALE 1:20

TRIMMER BARS FOR WALLS > 250 THK.

FOR HOLES <500


SCALE 1:20
X
1T20 T&B
CENTRAL T20 TRIMMERS
BOTH FACES
2No. BARS FIXED ON
INSIDE OF 'U' BARS

T16 TRIMMERS
NF & FF LAYERS 50 50
50% OF SPAN 50% OF SPAN
STEEL OR TOP STEEL OR TOP
STEEL WHICHEVER 100% SLAB STEEL STEEL WHICHEVER 100% SLAB STEEL
'U' BARS SAME SIZE IS THE GREATER IS THE GREATER
& CENTRES AS MAIN
HORIZONTAL STEEL

1+1T20 E.F. NOTES:-


TRIMMERS SLAB TO WALL CONNECTION SLAB TO BEAM CONNECTION T01 TENDER ISSUE 03/06/2016 CR IS
1. FOR HOLES WITH A MAXIMUM DIMENSION GREATER THAN SCALE 1:20 SCALE 1:20
Rev Description Date Drn Ch'd
300mm BUT LESS THAN 1000mm, PROVIDE HALF OF
REINFORCEMENT INTERRUPTED BY OPENING AT EACH
T16 TRIMMERS SIDE OF OPENING
NF & FF LAYERS

TENDER
2. FOR HOLES GREATER THAN 300mm 'U' BARS TO BE
PROVIDED ALONG EACH FACE. DIAMETER AND PITCH
OF 'U' BARS AS MAIN SLAB REINFORCEMENT.

3. DIAGONAL BARS FRAMING CORNERS OF HOLES TO BE


THE SAME DIAMETER AS THE LARGEST DIAMETER SLAB Status of drawing
BAR IN THAT AREA. 2 BARS TO PROVIDED IN SLABS SLAB 600
DIAMETER AS SLAB
TRIMMER BARS OVER 150mm THK. (1B3&1T3). 1 BAR ONLY REQUIRED IN
SLABS LESS THAN 150mm THK.
TYPICAL TRIMMER DETAILS STEEL SLAB STEEL SLAB STEEL TENSION LAP TENSION LAP SLAB
FOR HOLES >500 DIAGONAL BARS NOT REQUIRED AT CORNER OF HOLE
WHERE EDGE OF HOLE COINCIDES WITH CONCRETE
FOR DOOR OPENINGS IN WALLS STEEL
STEEL
SCALE 1:20 SCALE 1:20
BEAM OR WALL.
1T10

1T10
600 TENSION LAP 1T10 57-59 Bread Street Tel: +44 (0)131 345 5200
TENSION LAP Edinburgh Fax: +44 (0)870 351 9879
THIS DETAIL ALSO 600 TENSION LAP EH3 9AH Email: 035093@burohappold.com
APPLIES WHEN INVERTED TENSION LAP UK Web: www.burohappold.com

Architect HELEN LUCAS ARCHITECTS


Project
LAGGAN HOUSE
TYPICAL DETAIL CHANGE IN SLAB THICKNESS TYPICAL DETAIL STEP IN SLAB Drg Title
PROPOSED POOL HOUSE
SCALE 1:20 SCALE 1:20
TYPICAL REINFORCEMENT DETAILS
SHEET 01
Scales@A1

Drawn By
As indicated
CR
Job No.
035093
Checked By IS Drawing No.
S5075
Date JUN '16 Rev T01