1' - 0"
6 03 04
04 11
A-3 GENERAL ARCHITECTURAL NOTES PARTIAL ABBREVIATION LIST
1 DO NOT SCALE DRAWINGS. VERIFY ALL EXISTING CONDITIONS AT AT ACOUSTICAL CEILING TILE REFLECTED CEILING SYMBOL LEGEND
SITE BEFORE PROCEEDING WITH WORK. CLNG CEILING
02 2 ANY CONFLICT OR DISCREPANCY BETWEEN INFORMATION ON CONC CONCRETE
2' - 6"
03 TOOL RM
DRAWINGS AND ACTUAL FIELD CONDITIONS SHOULD BE BROUGHT EX EXISTING
09 05 03 TO THE PROFESSIONALS ATTENTION FOR RESOLUTION PRIOR TO FRP FIBERGLASS REINFORCED PANEL
CONF ROOM
07 CONF ROOM COMMENCING WITH WORK. GB GYPSUM BOARD 9'-0" AFF ADDITIONAL CEILING HEIGHT
2' - 6" 02
3 PARTITION DIMENSIONS INDICATED ARE FROM FACE OF CMU TO HT HEIGHT IN A PORTION OF A AT - 1
TLT 01 FACE OF CMU, FACE OF CMU TO FACE OF STUD, OR FROM FACE OF IR IMPACT RESISTANT SCHEDULED ROOM 7'-10" A.F.F.
04 MRGB MOISTURE RESISTANT GYPSUM BOARD
STUD TO FACE OF STUD UNLESS OTHERWISE NOTED
P PAINT
4 PROVIDE TILE BACKER BOARD (IN THICKNESS TO MATCH GYPSUM PLY PLYWOOD
03 WALLBOARD) IN LIEU OF GYPSUM WALLBOARD WHERE CERAMIC TILE
D W RC RESILIENT COVE BASE
IS INDICATED IN FINISH SCHEDULE RF ROOM FINISH NOTE CEILING CONSTRUCTION
5 REFER TO SHEET A-3 FOR WALL ASSEMBLIES S/H SEALER & HARDENER
04 SUB SUBFLOOR
06 WD WOOD
2'x4' ACOUSTICAL CEILING TILE
WIN WINDOW
03 WOC WALK OFF CARPET
HALLWAY
REFER TO DETAIL 4/A-4
05 GC, EC, AND AIR EQUIPMENT SPECIALTY CONTRACTOR TO REINSTALL EXISTING PIPES/ CONDUITS/
KITCHEN COMPONENTS SECURELY TO NEW WALL IN AS CLOSE TO SAME LOCATION AS POSSIBLE GENERAL CEILING NOTES
06 TEMPORARY DRYER LOCATION- GC TO PROVIDE TEMPORARY EXHAUST DUCT EXTENSION - EC TO
WOMENS TLT PROVIDE TEMPORARY POWER EXTENSION - REFER TO ELECTRICAL DWGS 1 ALL CEILING ELEVATIONS INDICATED ARE ABOVE LOCAL FINISHED FLOOR LEVEL. REFERENCE
07 NEW 2’-6” WIDE X 2’-6 LONG BY 2’-6’ DEEP CLEAR CONCRETE SUMP PIT W/ REMOVABLE METAL GRATE INTERIOR ELEVATIONS AS REQUIRED FOR FURTHER SOFFIT HEIGHT INFORMATION.
COVER AND ONE (1) BIG BOSS HIGH FLOW 3/4 HP SUMP/ EFFLUENT PUMP- MODEL SSBIG75. EC TO 2 CEILING GRID TO BE CENTERED IN ROOM OR SPACE, UNLESS OTHERWISE NOTED OR DIMENSIONED
PROVIDE POWER - REFER TO ELECTRICAL DWGS 3 REFER TO ROOM FINISH SCHEDULE FOR FURTHER MATERIAL INFORMATION.
08 PROVIDE NEW CASEWORK & COUNTERTOP TO REPLACE THE EXISTING IN ALL ASPECTS: SIZE/ LAYOUT/
MATERIALS/ HEIGHT/ ETC
EQUIP 09 REINSTALL ALL TEMPORARILY RELOCATED ITEMS TO THEIR ORIGINAL LOCATIONS- BY CONTRACTOR
VESTIBULE WHO RELOCATED THE ITEMS
LOBBY 10 CONNECT NEW FLOOR DRAIN TO EXISTING DRAIN PIPE
11 2" PVC SUMP PUMP DISCHARGE PIPE - INSTALL AGAINST WALL, RUN VERTICALLY & TIE INTO 6"
INSULATED STORM WATER PIPE AT CEILING
EMERGENCY
MEETING RM
RESPONSE
ETR
ETR
OVERALL FIRST FLOOR PLAN
1
1/8" = 1'-0" 45' - 0" MIN
2 18' - 5"
4 ETR ETR
A-3
A-3
10 4 CHIEF'S OFFICE
02
02 ETR
2'-0" MIN. 5 A-4
STAIR
A-3 ETR
ETR
01 04
01
TLT EX CONC. EX EX EX EX EX EX EX EX EX
E
S
SECOND FLOOR
BUNK RM MEETING RM EX CONC. CPT RC 4" MRGB/EX GB MRGB/EX GB EX GB EX GB EX EX RF-1, RF-5
EMERGENCY RESPONSE EX CONC. EX EX EX EX EX EX EX EX EX
CHIEF'S OFFICE EX CONC. CPT RC 4" EX GB MRGB/EX GB EX GB EX GB EX EX RF-1, RF-5
BUNK RM EX CONC. EX EX EX EX EX GB/EX EX EX EX RF-4
LOCKER RM EX CONC. EX EX EX EX EX EX EX EX EX
STO EX CONC. EX EX EX EX EX EX EX EX EX
W1 STAIR EX CONC. EX EX EX EX EX EX EX EX EX
SHWR EX CONC. EX EX EX EX EX EX EX EX EX
TLT EX CONC. EX EX EX EX EX EX EX EX EX
CLO EX CONC. EX EX EX EX EX EX EX EX EX
HALLWAY EX CONC. EX EX EX EX EX EX EX EX EX ARCHITECTS ENGINEERS, INC.
MEZZANINE EX CONC.
717-249-4569
OVERALL SECOND FLOOR PLAN ONE TYLER COURT FAX: 717-249-0284
2 CARLISLE, PA. 17015 EMAIL: info@sgsarchitects.com
1/8" = 1'-0"
NO. REVISION DATE BY (717) 939-9842 BOROUGH OF STEELTON DAUPHIN COUNTY PENNSYLVANIA DATE- JANUARY 2016 PROJECT 001337.0469