You are on page 1of 4

Visual Inspection Plate Report

Name [Block capitals]_______________________Signature ____________________ Test piece identification

Code/Specification used ______________________ Welding process ________________ Joint type__________________

Welding position______________ Length and thickness of plate _______________________ Date

Weld face
M
E A B C
A
S
U
R
E

F
R
O
M

T
H
I
S

D
A
T
U
M

E
D
G
E
Visual Plate Report
Weld Root

M A B C
E
A
S
U
R
E

F
R PART THREE – DEFECT ASSESSMENT FORM
O
M

T
H
I
S

D
A
T
U
M

O
N
L
Y
Sentence Sheet for Pipe/Plate Inspection Report

Print full name ………………………………………………………………..


Specimen Number …………………….

Imperfections
Face Imperfections reported Code or specification reference Sentence
Maximum Code Section Accept or
Maximum Value Allowed by or Reject
or Total Length Code Table No 4
Imperfection Types 1 2 3
Excess weld metal (height)
Toe blend / inter-run blend
Incomplete filling
Slag inclusions
Undercut
Surface porosity
Cracks
Lack of fusion
Arc strikes
Mechanical damage
Misalignment

Root Imperfections
Misalignment
Penetration (Height)
Lack of root penetration
Lack of root fusion
Root concavity
Root undercut
Cracks
Porosity
Burnthrough

This pipe/plate* has been examined to the requirements of [code/specification]


..........................…...
and is accepted/rejected* accordingly. [*Delete whichever is not applicable]

Signature..............….................................…….…
Date...............................

Use this space for any comments


Plate and Fillet Acceptance Standard
KEY:
L = length.
D = depth or height of defect.
W = width of defect (applicable to inclusions only
No Defect name Remarks Maximum allowed
1 Cracks Not permitted
2 Porosity, gas pores Max dimension of any area or 1mm
Elongated gas cavities individual (as applicable)
(worm holes) pipes
3 Overlap Accumulative total for both defects 20mm in weld face length
4 Lack of side wall fusion shall not exceed 20mm
5 Lack of root fusion Accumulative total for both defects 20mm in weld root length
6 Lack of penetration shall not exceed 20mm
7 Inclusions Accumulative total shall not exceed Individual maximum
(slag/silica etc) 15mm total “L” in weld length (root L<12mm. W<3mm
and face independent)
8 Undercut 10%t up to a maximum D
1mm
9 Root concavity Maximum D 1mm
10 Underfill/incompletely Not permitted
filled groove/lack of fill
11 Linear misalignment Maximum D
<10mm t 1.0mm
>10mm t 1.5mm
12 Arc strikes/stray arc Not permitted
13 Mechanical damage Dependant on depth and blend Seek advice
14 Angular misalignment Accept
15 Excess weld metal* Smooth transition is required/All 2mm D maximum
runs shall blend smoothly. No lack
of interun fusion
16 Excess penetration* 1.5mm D maximum

When linear misalignment is present the following shall be applied.

Excess weld metal


Maximum height to be measured from a direct line from the lowest plate, across weldment

Excess penetration
Maximum height to be measured from lowest plate