You are on page 1of 2

Cartridge Based Specific Protein Analyser

Parameters at a Glance Technical Specifications


Test Method Dual Test Method Nephelometry & Photometry
Display 7” Colour TFT Display
Product Code Product Name Pack Unit Measr. Range Reff. Range Expiry Light Source 650 nm Laser
12014004 ASO 30T IU/mL 50 - 1000 0 - 200 9 months Weight 7.5 Kg Without Battery
12014007 CRP 30T mg/L 0.5 - 300 0.0 - 6.0 9 months Laser Power 5 mw
Temperature Control Dry Heating
12014010 RF 30T IU/mL 10 - 100 0 - 18 9 months
Controlled 37 C +_ 0.2 C
o o
Temperature
12014019 HbA1c 30T % 3 - 15 4-6 9 months
Photo Detector Silicon Diode
12014013 Microalbumin 30T mg/L 5 - 200 0 - 25 9 months Calibration Smart Card Calibration
12014023 Ferritin 10T ng/mL 1 - 750 30 - 220 9 months User Interface Touch Screen Display
12014014 Cystatin C 10T mg/L 0.1 - 10 0.56 - 1.02 9 months Printer Inbuilt Thermal Graphic Printer
15 - 400 Barcode Reader Inbuilt Barcode Reader & Hand Held Reader (optional)
12014052 IgM 10T mg/dL 35 - 220 9 months
Syringe Pump 500 µl with 0.125 µl/Pulse Resolution
12014038 hsCRP 10T mg/L 0.15 - 10 1.0 - 2.9 9 months
PC Interface RS 232 Port( Data Transmission, External Barcode)
12014020 IgE 10T IU/mL 5 - 1000 28 - 140 9 months Power Supply 85-265 VAC 50/60Hz
12014054 IgG 10T mg/dL 360 - 3000 840 - 1700 9 months Power Consumption 100 W
12014053 IgA 10T mg/dL 35 - 630 110 - 410 9 months Result Storage 1000 Result
12014044 Lp(a) 10T mg/dL 1 - 115 up to 30 9 months Minimum Sample Volume 80 µl
Reagent CE Certified IVD Reagent Cartridges
12014032 Apo A1 10T mg/dL 15 - 300 107 - 177 9 months
12014033 Apo B 10T mg/dL 20 - 330 60 - 138 9 months Accessories : Instrument
12014034 C3 10T mg/dL 14 - 400 90 - 180 9 months Mispa-i3 Instrument 1 No.

ADL/BR/i3/R05-03/19 Company reserves the right to change any design and technical features of the product at any time, If needed.
12014035 C4 10T mg/dL 4 - 80 9 - 36 9 months Pipette 1 No.
Bottle Stand 1 No.
12014037 Haptoglobin 10T mg/dl 15 - 330 32 - 205 9 Months
Waste and water bottle 2 Nos.
12014026 D -Dimer 10T mg/L 0.05 - 10 0 - 0.5 9 Months
Printer Roll 2 No.
12014036 Ceruloplasmin 10T mg/dl 3 - 101 22 - 61 9 Months User Manual 1 No.
52014056 Vitamin D 10T ng/mL 7 - 100 30 - 100 9 Months
52014055 H.Pylori 10T UI/mL 3 - 100 up to 10 9 Months

ISO 9001:2015
EN ISO 13485:2016 * Toll Free No: 1800 425 7151
GLOBAL REVOLUTION AT ITS BEST
Automated Cartridge Based Specific Protein Analyser

“Agappe Hills”, Pattimattom (PO), Dist. Ernakulam, Kerala - 683 562, India.
TEL: + 91 484 2867000 | productcorp@agappe.in | www.agappe.com
Automated Cartridge Based Specific Protein Analyser Automated Cartridge Based Specific Protein Analyser Automated Cartridge Based Specific Protein Analyser

Inject Aspiration system (IAS): Aspirate desired


Product Description Add sample in reagent cartridges
volume of sample and test reagent to provide precise
Mispa-i3 is an automated Cartridge based specific protein analyser that offers the benefits of fully Auto
analyser, such as high precision and quick turnaround results, for all protein assays. 1 Efficient operation: Easy to use
and accurate result.

The key to analyser’s efficiency is ease to


Benefit: Auto - Dilution | Auto - Washing | Mixing of

Simple 3 Test Assay Procedure


operate.
Clinical Profile Management the solution.
Mastering the Mispa-i3 requires no
1. Diabetes special knowledge, which means it can be Smart Data Management System
2. Cardiovascular Risk put to use almost immediately. 1. Delivers a comprehensive overview of results
3. Acute Renal Dysfunction for each patient with demographic details.
4. Inflammation, Allergy & many more Single Cartridge system with multi point 2. Integrates test results from multiple
smart card calibration system removes the parameter for one patient ID
hectic manual calibration process and 3. Simplifies data management and data
Increased workflow efficiency Load the cartridge in the analyser transfer using RS232 port
ensure error free testing for all the

1. Dual Channel System: Nephelometry and


2 reagents for specific assay.
cv less than 3%
Turbidimetry Comprehensive solutions
2. Prefilled and sealed cartridges with Y= 1.0092X
18.0
convenient pack size Broad menu available from one source: R²= 0.996 LO T :
183 44 84 2
EXP :

Enhanced reagent stability – up to 9 months


Please keep the

3.
card in a clean
surface

Over 25 assay protocols available for


for reagents determination in various body fluids 15.0 Certified HbA1c Smart Card Unique Channel
4. Barcode identification for test specific Reagents Calibration Shifting Technology

cartridges, sample and patient Consolidation of special and routine


Evaluation Report (NGSP)

Mispa-i3 HbA1c (%)


identification. parameters to support disease state
12.0

5. Smart card calibration for reagent & cost management Samples in HbA1c ranges outline in the
saving 9.0 NGSP method comparison procedure.
6. Auto-mixing, Incubation and After 5-8 minutes, result is printed Innovative assays: For the method, comparison and quality
measurements for fast results with less
operator intervention
3 1. NGSP certified HbA1c reagent.
6.0
analysis, 40 samples are analyzed by
Agappe Diagnostics Ltd. and by European
7. Secure interruption of assay runs for 2. hsCRP – A trendsetting assay reference laboratory, ESRL#10.
calibration and reloading – no loss of data acknowledged as independent 3.0

marker of cardiovascular risk


Confidence in results 3. Cystatin C – Early marker for the 0.0
0.0 3.0 6.0 9.0 12.0 15.0 18.0
glomerular filtration rate
1. Proven nephelometric technology with 4. D-dimer- Early marker for deep HPLC Method (%)
increased sensitivity vein thrombosis and pulmonary
2. 3 QC level testing for each parameter. embolism Correlation Graph Mispa-i3 with HPLC
3. Optimal alignment of reagents and system (For HbA1c)
4. Prozone detection system to check false
negative results

INNOVATION AT ITS FINEST

You might also like