You are on page 1of 3

S P E CI F I C A T I O N

EMG
Merk : Sigma / Germany
Type : Neurowerk EMG

NEUROWERK EMG as a complete 4-channel neurophysiological measuring system for EMG, NCV and evoked potentials provides practically
possibilities for your work in hospitals or surgeries. The system incorporates all methods required in daily routine diagnostics of neurological
disorders. Our complete high-grade system renders your diagnostics easier and more efficient. Benefit from our system! You can expect utmost
quality in the examination results. The tried and tested modular hardware and software concept allows customized adaptation to your needs and
processes.

NEUROWERK EMG offers the ideal configuration for every application.

Always the ideal variant :


With up to2 electric stimulators and 4 external triggers
Modular system for configuration as:
EMG/NCV/SEP/AEP/VEP system
On instrument trolley
As a PC system

Fitted with the best amplifiers


4 channels
24-bit AID converter
50 kHz sampling rate per channel
Connection for temperature sensor
Internally switchable reference electrode

EMG software for flexible examinations


Freely configurable sequences and result tables
Split screen for lateral comparison
Export of the results to an external software (e.g.Excel)
Automatic selection and calculation of all parameters (latency , amplitude, area, NCV, and many more)

NVC
motor, sensible, inching, repetitive stimulation, F wave, reflexes
SEP
arms, legs, dermatomes, trigeminus, pudendus
AEP
early, middle and late acoustically evoked potentials (AEP),click ,tone and burst-evoked stimulation
VEP
Checker board pattern stimulation, LED goggles or flash stimulator
MEP
arms, legs, facialis, incl. F wave for determination of the central motor latencies(CML)
ANS
Sympathetic skin response (SSR), heart rate variability (HRV)
EMG
spontaneous, voluntary and maximum activity, triggered EMG, automatic quantitative MUP analysis, turn/amplitude analysis, single fiber EMG,
macro EMG

Always All Measurement Values in Views


S P E CI F I C A T I O N

Clear representation of curves in the lateral comparison, including calculation of the lateral differences. The results and reports can be sent
immediately to your hospital information system (HIS) or medical practice EDP via interface.

Automatic EMG Analysis


In addition to the manual selection of motor units by the examiner, the automatic EMG analysis provides all MUPs of an EMG sequence
simultaneously. Our user-friendly software is rounded off by T/A analysis and analysis of the spontaneous EMG which ensure meaningful results by
calculating all relevant parameters.

Integrated Help System


The Neuro anatomy Guide supports you in your daily work with valuable tips and thus contributes to the reliability of your examination results

EMG System Neurowerk EMG 4

Amplifier Type EMG 4


Channels 4
Dinamics Range ± 25mV
Input Impedance >100 MΩ
CMRR (complete system) > 116 dB
Noise < 1 µV at 0.01 Hz-20 kHz, shorted input
Lower Frequency Limit < 8 mHz, T> 20s, 6dB/octave
Upper Frequency Limit 20 Hz
Sampling Rate 50 kHz per channel
Sampling Resolution 24 Bit
Transfer Sensitivity 3nV/bit
Impedance Measurement 0-1.3 MΩ at 10 kHz
Notch Filter 50/60 Hz
Temperature Measurement 20-40˚C with temperature probe
Power Supply
Mains Voltage/Mains Frequency 100-230 V AC at 50-60 Hz
Power Input 22 W
Visual Stimulator
Stimulation Type Reverse pattern, flash (flash goggles, photic stimulator*)

Stimulation Displays 19” Displays by VGA


Pattern Chessboard, vertical stripes, horizontal stripes

Pattern Resolution 4, 8, 16, 32, 128 horizontal fields


Stimulation Fields full-field, half field, quarter field
Fixation Point red point, red cross, customized*
Flash Goggles*
Stimulation Type right eye, left eye, both eye
Electrical Stimulator
Number of Stimulators 1 or 2*
Operating Mode/Stimulus Intensity current constant, 400 V operating voltage, 0-100 mA, adjustable by 0.1 mA steps

Stimulation Type Single stimulus, cyclic stimulus, double stimulus, train


Stimulation Frequency 0-100 Hz freely selectable
Stimulus Series Max. 16 Impulses per Train with gap and delay
S P E CI F I C A T I O N

Accessories included:
Gold cup electrodes 12 pcs
Stimulation electrode 1 pc
Fixing tape for stimulation electrode 1 pc
Metal pins for stimulation electrode 2 pcs
Ring electrode 1 pc
Crocodile clamps for disposable surface electrodes 1 pc
Multifunctional cable for Myoline EMG electrodes and NCV 1 pc
Universal cable for EP and NCV studies 4 pcs
Bridge cable for universal cable 3 pcs
Elastic ground electrode tape 1 pc
Ground electrode cable 1 pc
Disposable surface electrodes (100 pcs.) 1 set/100pcs
Disposable Myoline EMG electrodes (starter kit with 5 pcs.) 1 set/5 pcs
Electrode gel 1 pc
Skin cleaning gel 1 pc
Eye pad for VEP 1 pc
Measuring tape 1 pc
Disposable Myoline EMG electrodes 1 set/ 25 pcs
UPS 650 VA 1 pc
Color Printer 1 pc
Trolley EMG 1