HM403C is a three-channel heat treatment unit for Tecnical data
preheating and annealing metal objects. Setting, control,
monitoring and documentation of heat treatment parameters is Connection voltage 400 V; 3 phase
carried out by hte computerized HeatMaster Control System. Heating power 40,0 kW, ED 100 %
HM403C provides accurate heat treatment and easy Fuse 63 A, slow
documentation. HM403C can be long-distance controlled. Secondary voltage 69 V
Programming Heating channels 3 pcs
Heat treatment parameters are programmed in the memory of the Measuring points 6 pcs
three regulators of the unit and the heating will be started at any Temperature range 20 ... 1200 °C
desired time. HM403C will carry out the programmed heat Control system HeatMaster Temperature
treatment process according to the given phases. Control System
Data registration Alarm Signal lights, option for
The unit registers in its memory the achieved heat treatment long distance monitoring
results, which enable easy preparation of heat treatment Dimensions Width 600 mm
documents. A separate temperature recorder is not needed Depth 600 mm
Capacity Height 1020 mm
HM403C has three heating channels and three independent Weight 150 kg
programming alternatives. The signal lights of HM403C will
alarm of any disturbances of the electric network and/or the
heating elements, and of any other disturbances during the
heat treatment.
SIGNAL LIGHT SYSTEM PREHEATING RESISTORS
HM406 has a signal light system, which assist the user to state
the operating status of the device and heating elements.

VET preheating resistors are designed for preheating flat and


cylindrical objects. Ceramic beads, covered by a fireresistant
net, is used for thermal insulation.

Three white lights indicate the status of the electric network. VEK preheating resistors are designed for preheating flat
Big green light indicates, that HM403C is connected to the objects. Mineral wool and ceramic beads are used for thermal
electric network. insulation.
Small green lights indicates the status of the process and are
giving signal of an alarm. VLV channel resistors can be used for preheating and annealing.
Red lights indicate that the resistors are recieving heating energy They can also be used as power source for temporary furnaces.
The spiral resistance wire, heated by low voltage enegry, is
CONTROL SYSTEM OF THE HEATMASTER placed inside ceramic insulation beads, which stand very high
HEATING PROCESS temperatures. The resistor is placed inside a heat resistant case.

HeatMaster Temperature Control System is used for the control, ANNEALING RESISTORS
monitoring and documentation of heat treatment processes.
System properties: A flexible, multifibre resistor cable, heated by low voltage energy,
* high capacity: capable of controlling dozens of devices is placed inside ceramic insulation beads. The material of the
* easy to control, remote control also available tails does not heat up during the heat treatment.
* versatile programming aternatives, even 14 different VHV annealing resistors are designed for the preheating, stress
heating phases relief annealing and normalization of objects with bend or flat
* clear documentation, easy to file surface

VHY connection resistors are designed for annealing tube


connections and outlets. The shape of the resistor enables to
place it near to the welding seam.

VHVP annealing resistors are designed for preheating, stress


relief annealing and normalization of tubes with small diameters.