Professional Documents
Culture Documents
30HZ043 to 280
Technical data
30HZ Water cooled chiller 043 052 065 091 101 111 121 141 161 195 225 250 280
Net nominal cooling capacity* kW 134 153 199 230 270 300 316 371 415 533 626 719 783
Unit nominal power input** kW 36.8 46.6 64 66 74 85 88 106 124 155 187 221 249
Unit dimensions mm
height 1370 1355 1915 1915 1915 1950 2000
length 2252 2550 2630 2940 3350 4255 4070
depth 915 915 950 950 950 950 1275
Operating weight kg 1075 1165 1232 2020 2350 2440 2490 2710 2810 3480 3780 4440 4870
Refrigerant charge R407-C
Compressors Semi-hermetic, 4 or 6 cylinders 24.2 r/s (1450 rpm)
Quantity, circuit A 1 1 1 2 2 2 2 2 2 3 3 4 4
Quantity, circuit B 1 1 1 1 2 2 2 2 2 2 3 3 4
Control type PRO-DIALOG Plus
Evaporator Direct-expansion evaporator, one or two circuits, multi-tube shell
Max. water-side operating pressure kPa 1000
Condensers Shell and multi-tube type
Max. water-side operating pressure kPa 1000
Power circuit
Legend:
* Net nominal cooling capacity = gross cooling capacity minus the water pump heat against the internal evaporator pressure drop
** Unit nominal power input, including the power input of the compressors, fans, control circuit and the power input of the pump against the unit pressure drops.
Nominal Eurovent conditions: evaporator entering/leaving water temperature 12°C and 7°C. Condenser entering/leaving water temperature 30°C and 35°C.
LITERATURE