RTHD evo

SE/HE/XE/HSE

Water-cooled helical-rotary liquid chillers


550-1460 kW

RLC-PRC045B-GB
Introduction
Technical Data
Trane offers water-cooled helical rotary compressor
chillers, the model RTHD Evo.
The industrial-grade design of this helical rotary chiller
is ideal for both industrial and commercial markets, in
applications
FWD such as office buildings, hospitals, schools,
08 12 20 30 45
Power buildings,
retail supply (V/Ph/Hz)
and industrial facilities. 230/1/50
Capacities
The model
Cooling RTHD
capacity Evo (1)
on water features: (kW) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
• Fan
High
motor
energy efficiency (type) 2 x direct drive centrifugal
• Fan
High
powerreliability
input (3) (kW) 0,23 0,46 0,65 1,04 1,51
• Current
Bolt together
amps (3) construction (A) 1,1 2,2 3,1 4,7 5,5
• Start-up
R134aampsrefrigerant (A) 3,2 5,5 9,3 14,1 16,5
Air flow
• minimum
“Adaptive Control™” (m3/h) 490 980 1400 1800 2700
• nominal
Tracer UC800 controls enable: (m3/h) 820 1650 2300 3000 4500
maximum (m3/h) 980 1970 2600 3600 5400
–Main
– Scrolling
coil
access to inputs and operating information
touch
Water screen TD7connections
entering/leaving (type) ISO R7 rotating female
–– Freedom from interoperability concerns (Dia)with 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric
LonMark ®(accessory
heater for blower only)
communications
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
–Heating
– Job specific
capacity communication options that (kW) allow greater
2/4 8 10 12 12
Hotreporting
water coil flexibility,
(accessory forthrough BACnet and Modbus
blower only)
Heating capacity
protocols, (4)
integrated on Tracer UC800(kW) 6,3
chiller controller. 12 17,4 22,4 34,5
G2 filter (filter box accessory)
• Quantity
Improved startup temperature capabilities and reduced 2 2 2 2 2
sensitivity
Dimensions to condenser water temperatures
( LxWxth) (mm) alleviate
386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
the most common startup concerns
Quantity - 2 2 2 2
• Dimensions
Removed Liquid Vapor Separator, providing
( LxWxth) (mm) lighter - 486x264x48 586x314x48 586*414*48 586*614*48
unit weight
Condensate pump and simplified refrigerant(type)
(accessory) piping, for less Centrifugal
Water flow - lift handling,
expensive height separation, and(l/hinstallation
- mm) 24 - 500
Not available for FWD30 and FWD45
With
Soundits extensive
level compressor development and
(L/M/H speed)
manufacturing
Sound pressure level experience,
(5) Trane designs and build 36/40/43
(dB(A)) 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
chillers with a higher efficiency and reliability than the
Unit dimensions
units
Width available
x Depth on today’s market. (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
The linear unloading compressor, wide(mm)
Height operating 250 300 350 450 650
Shipped unit dimensions
temperature
Width x Depth range, advanced controls, electronic
(mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
expansion
Height valve, short anti-recycle timers, (mm) and industry- 260 310 360 460 660
Weight efficiencies mean that this Trane
leading (kg)
chiller is the 32 46 61 76 118
Colour galvanised steel
perfect choice for tight temperature control in almost
Recommended fuse size
any
Unit application
alone (aM/gI) temperatures, and under (A)widely 8/16 8/16 8/16 8/25 8/25
varying loads.
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

4

2 © Trane 2018 UNT-PRC002-GB
RLC-PRC045B-GB
Table of Contents
Introduction........................................................................................................ 2

Features and Benefits......................................................................................... 4


Sound power levels
Application
Discharge Considerations............................................................................. 10
Measurement conditions:
Selection
Measurements Procedure.........................................................................................
taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m13
long) fixed to its discharge opening.

Unit Model Fan


Number.........................................................................................
Power level in dB(A), per Hz frequency band 14
Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
General Data..................................................................................................... 16
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
Electrical Data................................................................................................... 22
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
Dimensions....................................................................................................... 24
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 46 45 60
Dimensions and Weights................................................................................. 25
3 63 69 58 56 50 50 49 63

Intake
Mechanical Specifications............................................................................... 36
Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

UNT-PRC002-GB
RLC-PRC045B-GB 131
Features and Benefits
Technical Data
Application Versatility and High Simple, Economical Installation
Performance • C ompact size makes the model RTHD Evo well suited
• S crew compressor technology and the electronic for the retrofit and replacement market.
expansion valve provide reliable performance in an • All units fit through standard double-width doors.
FWD
expanded
08 • Bolt-together 12construction makes 20 for fast, 30easy unit 45
Power supply range of operating temperatures. (V/Ph/Hz) 230/1/50
• Capacities
Tight water temperature control extends to operation disassembly.
of multiple
Cooling capacitychillers
on water in
(1) parallel or series configurations,
(kW) 5,2 • Small RTHD8,3 Evo footprint saves 15 valuable equipment
18,8 30,1
Heating capacity on water (2)
offering further system design flexibility (kW)
for maximum 6,3 room space11,9 and alleviates 18,9 access concerns 20,9 for most 38,2
Fan motor (type) retrofit jobs. 2 x direct drive centrifugal
efficiency.
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
• Current
Advanced amps (3) design enables chilled water (A)temperature1,1 • Light weight2,2design simplifies 3,1 rigging requirements,
4,7 5,5
Start-up
control amps to +/‑ 0.28°C for flow changes (A) up to 10% per 3,2 further reducing
5,5 installation9,3time requirements
14,1 and16,5
Air flow
minute, plus handling of flow changes costs.
minimum 3
(m up
/h) to 30% per490 980 1400 1800 2700
minute for comfort cooling.
nominal 3
(m /h) 820
• Full factory1650
refrigerant or nitrogen
2300
and oil
3000
charges 4500
• maximum
Two-minute stop-to-start and five-minute 3
(m /h) start-to- 980 reduce required
1970 field labor, materials, and
2600 3600installation
5400
Main coil
start anti-recycle timer allows tight chilled water cost.
Water entering/leaving connections (type) • Only evaporator and ISOcondenser
R7 rotating female
water piping is
temperature control in constant or transient (Dia) low-load
3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
applications.
Electric heater (accessory for blower only) required; no starter water cooling (with its associated
• Electric
LonMark powercommunications
supply (V/Ph/Hz)
capability provides 230/1/50 safety230/1/50
concerns) or field piping
or 400/3/50 400/3/50 is necessary.
400/3/50 400/3/50
Heating capacity
excellent, trouble-free interoperability.
(kW) 2/4 • Oil cooler and 8 purge system 10connections12have been12
Hot water coil (accessory for blower only)
• Heating
Generic Building
capacity (4) Automation System(kW) points are 6,3
eliminated. 12 17,4 22,4 34,5
G2available
filter (filter for
box easy access to operation information,
accessory) • Simple power connection simplifies overall
Quantity
as well, as BACnet and Modbus communication 2 installation. 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 • SE, HE, and486x271x8
XE versions586x321x8
are supplied586*421*8
with unit 586*621*8
G4capabilities,
filter (filter boxalready
accessory)integrated on Tracer UC800 chiller
Quantitycontroller. - mounted and2 factory tested,2 Star-Delta starter, 2 2
Dimensions ( LxWxth) (mm) - eliminating additional job
486x264x48 site installation
586x314x48 586*414*48 586*614*48
Industrial/Low
Condensate pump Temperature Process Cooling
(accessory) (type) considerations and labor requirements.
Centrifugal
Water flow -operating
Excellent lift height temperature range (l/hand
- mm) precise 24 - 500
Not available for FWD30 and FWD45
• HSE versions (Adaptive Frequency Drive) make the
control capabilities
Sound level (L/M/H speed)
enable tight control with single chiller compressor start through the AFD, minimizing the start
or series
Sound configuration.
pressure level (5) (dB(A)) 36/40/43 amp up to38/41/44
25% of the inrush current. 47/52/57
46/50/53 47/52/58
Sound power level (5) (dB(A)) 46/50/53 • Trane has48/51/54
conducted extensive 56/60/63 factory57/62/67
testing, and 57/62/68
Ice/Thermal Storage - Specifiers and operators benefit
Unit dimensions
from
Width dual setpoint control and industry-leading
x Depth (mm) 890 x 600 also offers options
1090 x 710 for in-person
1290 x 820 and/or documented
1290 x 970 1290 x 1090
temperature,
Height efficiency, and control capabilities,
(mm) that 250 system performance
300 verification.
350 450 650
Shipped unit
minimize dimensions
design time and energy costs. • Tracer UC800 controls easily interface with Tracer
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008
Height (mm) 260
Summit™ building
310
automation360
systems through 1333*1133
460
single
660
Weight (kg) 32 twisted-pair 46 wire. 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

4 UNT-PRC002-GB
RLC-PRC045B-GB
Features and Benefits

Features and Benefits: Control System Control options


Superior Control with Tracer™ UC 800 Chiller Controls BACnet™ communications interface
The Adaptive Control™ microprocessor system Allows the user to easily interface with BACnet via a
enhances the RTHD Evo chiller by providing the very single twisted pair wiring to a factory installed and
Sound power
latest chiller levels
control technology. With the Adaptive tested communication board.
Control microprocessor, unnecessary service calls
Discharge LonTalk™ (LCI-C) Communications Interface
and unhappy tenants are avoided. The unit does not
nuisance-trip or unnecessarily shut down. Only when Provides the LonMark chiller profile inputs/outputs for
Measurement conditions:
the Tracer chiller controls have exhausted all possible use with a generic building automation system via a
Measurements taken in a room adjacent to the
corrective actions and the unit is still violating an room containing single twisted
the FWD, pairoutlet
at the wiringoftothe
a factory installed
rectangular ductand
(1.5 m
long) fixed to limit,
operating its discharge opening.
will the chiller shut down. Controls on tested communication board.
other equipment typically shut down the chiller, usually ModBus™ Communications Interface
Fan the most.
just when it is needed Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 Allows
1000 the user to easily interface
2000 4000 with ModBus dB(A)
8000 via
UC 800 optimization 1 software 55 controls operation
50 of the
42 37
a single twisted37pair wiring31to a factory 30 46
installed and
FWDrequired
08 equipment2 and accessories 57 54
to easily 47
move from 40 30 38 40 50
3 58 57 50 tested
42 communication
32 board.
40 43 53
one mode of operation 1 to another.
57 For example:
51 even45 42 34 33 28 48
FWDwith
10 ice-storage systems,
2 there
58 are numerous
54 hours 48 External
45 chilled38water setpoint
39 35 51
when ice is neither3produced nor 60 consumed, 58 but saved. 50 UC80048 accepts 40 either a 2-1042VDC or a 4-20mA
39 54
input
1
In this mode, the chiller is the 57
sole source51of cooling.45 For 42
signal,
34 33 28 48
FWD 12 2 58 54 48 45 to adjust38the chilled39 water setpoint
35 from a 51remote
example, to cool the 3 building after
60 all ice is
58 produced 50 location.
48 40 42 39 54
but before high electric
1 al- demand
56 charges62 take effect,50 48 39 38 36 56
FWDUC14 800 sets the chiller
2 leaving-61fluid set point
66 55
to its most External
53 current47limit setpoint
46 45 60
3 63 69 58 56
efficient setting and1 starts the 57 chiller, chiller UC800 accepts 50 50
either a 2-10VDC 49
or a 4-20mA input63
63 pump, and 51 49 40 39 37 57
FWDload
20 pump. 2 61 66 55 signal
53 to adjust47the current46limit setpoint45 from a remote
60
3 63 69
When electrical demand is high, the ice pump is started 58 location.
56 50 50 49 63

and the chiller is either demand limited or shut down Ice making contact
Intake
completely. UC 800 controls have the intelligence to UC800 provides an output contact closure that can be
optimally balance the contribution of the ice and the used as a signal to the system that ice building is in
Measurement conditions:
chiller in meeting the cooling load. operation. This relay will be closed when ice building
Measurements taken at the horizontal air intake.
The capacity of the chiller plant is extended by operating is in progress and open when ice building has been
the chiller and ice Fan
in tandem. UC 800 rationsPowerthe ice,
level in dB(A), perterminated by either UC800 or the remote interlock.
Hz frequency band It is
Overall power
Unitaugmenting chiller capacity while
speed 125 reducing 250 cooling 500 used1000
to signal 2000
the system4000 8000
changes required dB(A) to
to convert
1
costs. When ice is produced, 56 800 will lower
UC 55 the 55 53 46 45 42 57
FWD 08 2 63 62 60
and60 from ice making.
53 53 53 64
air-cooled chiller leaving-fluid
3 set point and
66 65 start the 63 62 56 55 57 67
chiller, ice and chiller
1 pumps, and62 other accessories.
58 Any
55
Tracer
58
UC800 Controller
51 48 44 61
FWDincidental
10 2 persist while
loads that 66 63 ice can 60
producing be Today’s
62 RTHD Evo 56 chillers offer
55 predictive
52 controls66that
3 70 67 63 65 59 59 57 69
addressed by starting the load62pump and58 drawing spent anticipate and compensate for load changes. Other
1 55 58 51 48 44 61
FWDcooling
12 fluid from the
2 ice storage
66 tanks. 63 60 control
62 strategies56 made possible
55 with 52
the Tracer UC800
66
3
For specific information on ice70storage applications,
67 63 controls
65 are: 59 59 57 69
1 66 65 65 65 57 50 46 68
FWDcontact
14 your local sales
2 office.73 72 69 Feedforward
71 Adaptive
64 Control
59 57 74
3 78 76 73 75
Feedforward is 69 64 predictive
an open-loop, 63 control strategy
78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68
designed
71
to anticipate
65
and61compensate61
for load changes.
75
3 78 79 71 It uses
74 evaporator
69 entering-water
66 temperature
66 as78an
indication of load change. This allows the controller
to respond faster and maintain stable leaving-water
temperatures.
Soft Loading
The chiller controller uses soft loading except during
manual operation. Large adjustments due to load or
setpoint changes are made gradually, preventing the
compressor from cycling unnecessarily. It does this by
internally filtering the setpoints to avoid reaching the
differential-to-stop or the demand limit. Soft loading
applies to the leaving chilled-water temperature and
demand limit setpoints.

UNT-PRC002-GB
RLC-PRC045B-GB 151
Features and Benefits
Technical Data
Adaptive Controls Display Features Include:
There are many objectives that the controller must meet, • Factory-mounted above the control panel door
but it cannot satisfy more than one objective at a time. • UV Resistant touchscreen
Typically, the controllers primary objective is to maintain • -40°C to 70°C Operating temperature
the
FWDevaporator leaving water temperature. 08 • IP56 rated 12 20 30 45
Power supply (V/Ph/Hz) • CE certification 230/1/50
Whenever
Capacities
the controller senses that it can no longer
meet
Cooling itscapacity
primary objective
on water (1) without triggering
(kW) a protective5,2
• Emissions:EN55011
8,3
(Class B) 15 18,8 30,1
shutdown,
Heating capacity it focuses
on water on (2) the most critical (kW)secondary 6,3 • Immunity:EN61000
11,9 (Industrial)
18,9 20,9 38,2
Fan motor
objective. When the secondary objective (type)
is no longer • 7” diagonal 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 • 800x480 pixels0,46 0,65 1,04 1,51
critical, the
Current amps (3) controller reverts to its primary(A) objective 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) 3,2 • TFT LCD @ 5,5 600 nits brightness 9,3 14,1 16,5
Rapid
Air flowRestart • 16 bit color graphic display
minimum
The controller allows the chiller to perform (m3/h) a Rapid 490 Display features: 980 1400 1800 2700
nominal (m3/h) 820 1650 2300 3000 4500
Restart.
maximum
A Rapid Restart is performed after (m3/h)
a momentary 980
• Alarms 1970 2600 3600 5400
power
Main coil loss if it occurs during operation. Similarly, if • Reports
the
Waterchiller shuts down
entering/leaving on a non-latching
connections diagnostic and
(type) • Chiller settings ISO R7 rotating female
the diagnostic later clears itself, a Rapid(Dia) Restart will be 3/4" 3/4"
• Display settings 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
initiated.
Electric power supply (V/Ph/Hz) 230/1/50 • Graphing
230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 • Support for 15 8 languages 10 12 12
AdaptiSpeed Controlfor blower only)
Hot water coil (accessory
Heating
The speedcapacity (4)
control (kW)
is now optimized mathematically 6,3
and 12 17,4 22,4 34,5
G2 filter (filter box accessory)
controlled
Quantity simultaneously. The increased performance 2of 2 2 2 2
the UC800( controller
Dimensions LxWxth) allows the chiller (mm)
to operate longer
386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
at
G4higher efficiency,
filter (filter box accessory)and with greater stability.
Quantity - 2 2 2 2
Variable-Primary
Dimensions ( LxWxth)Flow (VPF) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Chilled-water systems that vary the water
Water flow - lift height flow through
(l/h - mm) 24 - 500
chiller evaporators
Not available for FWD30have caught the attention of
and FWD45
Sound level (L/M/H
engineers, speed) building owners, and operators.
contractors,
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Varying
Sound power the level
water (5) flow reduces the energy (dB(A))consumed by
46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
pumps, while having limited effect on the chiller energy
Unit dimensions
consumption.
Width x Depth This strategy can be a significant (mm) source
890 xof 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
energy savings, depending on the application.
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
TD7 Operator Interface
Height (mm) 260 310 360 460 660
The
Weightstandard TD7 display provided with(kg) the Trane UC800 32 46 61 76 118
Colour
controller features a 7” LCD touch-screen, allowing galvanised steel
Recommended fuse size
access
Unit alone to(aM/gI)
all operational inputs and outputs. (A) This is an8/16 8/16 8/16 8/25 8/25
advanced interface
Unit with electric heater that
(gI) allows the user (A) to access 16 any
(2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25
important information concerning setpoints, active
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
temperatures,
(2) Conditions: Watermodes, electrical
entering/leaving data,
temperature: pressure,
50/45 and
°C, Air inlet temperature 20°C DB - Nominal air flow
diagnostics.
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

4
6 UNT-PRC002-GB
RLC-PRC045B-GB
Features and Benefits

Tracer TU Interface System Integration


Tracer TU (n on-Trane personnel, contact your local Trane Stand-Alone Controls
office for software) adds a level of sophistication that
Single chillers installed in applications without a building
improves service technician effectiveness and minimizes
management system are simple to install and control:
Sound
chiller power
downtime. levels
The portable PC-based service-tool
only a remote auto/stop for scheduling is required for
software, Tracer TU, supports service and maintenance
unit operation. Signals from the chilled-water pump
tasks. Tracer TU serves as a common interface to all
Discharge ® contactor auxiliary, or a flow switch, are wired to the
Trane chillers, and will customize itself based on the
chilled-water flow interlock. Signals from a time clock or
properties of
Measurement the chiller with which it is communicating.
conditions: some other remote device are wired to the external auto/
Thus, the service
Measurements takentechnician
in a roomlearns onlytoone
adjacent theservice
room containingstop the input.
FWD, at the outlet of the rectangular duct (1.5 m
interface.
long) fixed toThe
its panel bus is
discharge easy to troubleshoot using
opening.
LED sensor verification. Only the defective device is • Auto/Stop-A job-site provided contact closure turns the
replaced. Tracer TUFancan communicate withPower individual unit on and off.
level in dB(A), per Hz frequency band Overall power
Unitdevices or groupsspeed
of devices. All
125 chiller status,
250 machine 500 • E1000
xternal Interlock-A
2000 job-site
4000 provided8000 contact opening
dB(A)
1
configuration settings, 55
customizable limits,50and up to 42 100 wired
37 to this input
37 turns 31
the unit off 30
and requires46 a
FWD 08 2 57 54 47 40
manual reset30of the unit 38 40
microcomputer. 50
This closure is
active or historic diagnostics
3 are
58 displayed 57 through the50 42 32 40 43 53
service-tool software 1 interface.57
LEDs and their51 respective 45 typically
42 triggered
34 by a job-site
33 provided
28 system48such
FWDTracer
10 TU indicators2 visually confirm
58 the availability
54 of48 as45a fire alarm.
38 39 35 51
3 60 58 50 48 40 42 39 54
each connected sensor, relay, and actuator. Tracer TU is
1 57 51 45 42 34 33 28 48
FWDdesigned
12 to run on 2a customer’s58 laptop, connected
54 to 48
the 45 38 39 35 51
Tracer AdaptiView control
3 panel
60 with a USB 58 cable. Your 50 48 40 42 39 54
laptop must meet the 1 following 56hardware 62 and software 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
requirements: • 1 GB 3 RAM (minimum)
63 • 1024
69 x 768 screen 58 56 50 50 49 63
resolution • CD-ROM 1 drive • Ethernet
57 10/100
63 LAN card51 • 49 40 39 37 57
FWDAn20 available USB 2.0 2 port • Microsoft
61 ® Windows
66 ® XP55 53 47 46 45 60
3
Professional operation system63 with Service 69
Pack 3 (SP3) 58 56 50 50 49 63

or Windows 7 Enterprise or Professional operating system


Intake
(32-bit or 64-bit) • Microsoft .NET Framework 4.0 or later
Note: Tracerconditions:
Measurement TU is designed and validated for this
Measurements takenconfiguration.
minimum laptop Anyair
at the horizontal variation
intake. from this
configuration may have different results. Therefore,
support for Tracer TU
Fan is limited to only those laptops
Power with per Hz frequency band
level in dB(A), Overall power
Unitthe configurationspeed
previously specified.
125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWDTracer
08 TU Interface 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

UNT-PRC002-GB
RLC-PRC045B-GB 171
Features and Benefits
Technical Data
Hardwire Points Tracer Summit
Microcomputer controls allow simple interface with The chiller plant control capabilities of the Trane Tracer
other control systems, such as time clocks, building Summit™ building automation system are unequaled in
automation systems, and ice storage systems via the industry. Trane’s depth of experience in chillers and
hardwire
FWD points. This means you have the flexibility 08 controls makes 12us a well-qualified
20 choice for30 automation
45
Power
to meet supply
job requirements while not having (V/Ph/Hz)to learn a 230/1/50chillers. Our chiller plant
of chiller plants using air-cooled
Capacities
complicated control system.
Cooling capacity on water (1)
Remote devices
(kW)
are wired5,2
automation software
8,3
is fully pre-engineered
15
and tested.
18,8 30,1
from
Heatingthe control
capacity panel(2)to provide auxiliary
on water (kW) control 6,3 Required features:
11,9 18,9 20,9 38,2
to
Fana motor
building automation system. Inputs and outputs
(type) 2 x direct drive centrifugal
Fan power input (3) • L onTalk/Tracer0,46 Summit Interface (selectable
1,04 option 1,51
can be communicated via a typical 4–20(kW)
mA electrical0,23 0,65
Current amps (3) (A) 1,1 with chiller) 2,2 3,1 4,7 5,5
signal, an
Start-up ampsequivalent 2–10 V dc signal, or(A)by utilizing 3,2 5,5 9,3 device required)
14,1 16,5
• Building Control Unit (external
contact
Air flow closures. This setup has the same features as a
minimum (m /h) of having 490 • Sequences starting
980 of chillers
1400 to optimize1800the overall
2700
stand-alone water chiller, with the possibility 3

nominal (m /h) 3
820 chiller plant1650energy efficiency2300 3000 4500
additional optional features:
maximum (m /h) 3
980 −− Individual
1970chillers operate
2600 as base, peak,
3600 or 5400
• Main
Ice coil making control. swing based onISO capacity and efficiency
• Water
Externalentering/leaving connections (type)
chilled water setpoint, external demand limit −− Automatically
R7 rotating female
rotates 1individual chiller
(Dia) 3/4" 3/4" 1/2" 1 1/2" 1 1/2"
setpoint
Electric heater (accessory for blower only) operation to equalize runtime and wear between
• Electric
Chilled powerwater temperature reset. (V/Ph/Hz)
supply 230/1/50 230/1/50 or 400/3/50
chillers 400/3/50 400/3/50 400/3/50
• Heating capacity
Programmable (kW) are: alarm-2/4
relays - available outputs 8 10
−− Evaluates and selects the lowest energy
12 12
Hot water coil (accessory for blower only)
latching, alarm-auto reset, general alarm-warning,
Heating capacity (4) (kW) 6,3 consumption
12 alternative17,4from an overall
22,4 system 34,5
G2chiller limit
filter (filter mode,
box compressor running, and Tracer
accessory) perspective.
control.
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 • Regulatory Compliance 586x321x8
486x271x8 Documentation 586*421*8 586*621*8
BACnet Interface
G4 filter (filter box accessory) • Gathers information and generates the reports
Quantity
Tracer TD7 control can be configured for BACnet - mandated in2ASHRAE Guideline 2 3. 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
communications
Condensate pump (accessory)at the factory or in the field.
(type) This • E
 asy Operation and Maintenance
Centrifugal
enables
Water flowthe - liftchiller
height controller to communicate
(l/h - mm) on a • Remote monitoring and control 24 - 500
Not available
BACnet MS/TP for FWD30
network.and FWD45
Chiller setpoints, operating • Displays both current operation conditions and
Sound level (L/M/H speed)
modes, alarms, and status can be monitored
Sound pressure level (5) (dB(A))
and 36/40/43 scheduled38/41/44
automated control actions 47/52/57
46/50/53 47/52/58
controlled
Sound powerthroughlevel (5) BACnet. Tracer TD7(dB(A)) controls 46/50/53 • Concise reports
48/51/54 assist in 56/60/63
planning for preventative
57/62/67 57/62/68
conforms to
Unit dimensionsthe BACnet B-ASC profile as defined by maintenance and verifying performance
Width x Depth
ASHRAE 135-2004. (mm) 890 x 600 Alarm notification
1090 x 710and diagnostic
1290 x 820messages
1290 x aid
970 in1290
quickx 1090
Height (mm) 250 300 350 450 650
Shipped and accurate troubleshooting
Lon Talkunit dimensions
Communications Interface (LCI-C)
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
The optional Lon Talk® Communications
Height (mm)Interface for 260 310 360 460 660
Weight (LCI-C) is available factory or field
Chillers (kg) installed. 32 46 61 76 118
Colour galvanised steel
ItRecommended
is an integrated communication
fuse size
board that enables
the
Unitchiller controller to communicate over
alone (aM/gI) (A) a LonTalk 8/16 8/16 8/16 8/25 8/25
network. The LCI-C
Unit with electric heateris capable of controlling
(gI) (A) and 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25
monitoring chiller setpoints, operating modes, alarms,
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
and status.Water
(2) Conditions: The entering/leaving
Trane LCI-Ctemperature:
provides50/45 additional
°C, Air inlet points
temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
beyond the standard LONMARK ® defined chiller profile
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
to
(5) extend interoperability
A rectangular glass wool duct 1m50andlongsupport
is placed onathebroader
blower.Therange
measurement is taken in the room containing the blower unit.
of system applications. These added points are referred
Heat exchanger operating limits:
to
FWD:as open extensions. The LCI-C is certified to the
*water temperature: max 100° C
LONMARK Chiller Controller Functional Profile 8040
*absolute service pressure: min 1 bar/max 11 bars
version 1.0, and follows LonTalk FTT-10A free topology
Accessories - Hot water coil:
communications.
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Modbus Interface Tracer TD7 control can be configured
for Modbus communications at the factory or in the field.
This enables the chiller controller to communicate as
a slave device on a Modbus network. Chiller setpoints,
operating modes, alarms, and status can be monitored
and controlled by a Modbus master device.

4
8 UNT-PRC002-GB
RLC-PRC045B-GB
Features and Benefits

Reliability and Ease of Maintenance


• D irect drive, low-speed compressor - a simple design
with only 3 moving parts - provides maximum
efficiency, high reliability, and low maintenance
Sound power levels
requirements.
• Electronic expansion valve, with fewer moving parts
than alternative valve designs, offers highly reliable
Discharge
operation.
• Suction gas-cooled
Measurement conditions:motor stays uniformly cool at
lower temperatures
Measurements taken in a for longer
room motortolife.
adjacent the room containing the FWD, at the outlet of the rectangular duct (1.5 m
• T
 he Trane helical rotary compressor
long) fixed to its discharge opening. is a proven design
resulting from years of research and thousands
of test hours, including
Fan extensive testing under
Power level in dB(A), per Hz frequency band Overall power
Unit extraordinarily speed
severe operating
125 conditions.
250 500 1000 2000 4000 8000 dB(A)
• Trane is the world’s1 largest manufacturer
55 50 of large 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
helical rotary compressors,
3 with
58 tens of thousands
57 50 42 32 40 43 53
of commercial and 1 industrial57installations
51 worldwide 45 42 34 33 28 48
FWD 10demonstrating a 2reliability rate 58 of greater 54 than 99%48in 45 38 39 35 51
3 60 58 50 48 40 42 39 54
the first year of operation.
1 57 51 45 42 34 33 28 48
Operating and32 Life Cycle
FWD 12 58
60
Cost- 58
54 48
50
45
48
38
40
39
42
35
39
51
54
Effectiveness 1 56 62 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
• Electronic expansion
3 valve enables
63 exceptionally
69 tight
58 56 50 50 49 63
temperature control
1 and extremely
57 low63superheat,51 49 40 39 37 57
FWD 20resulting in more2efficient full-load
61 and 66
part-load 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
operation than previously available.
• Precise compressor rotor tip clearance ensures optimal
Intake
efficiency.
• Condenser and evaporator tubes use the latest heat
Measurement conditions:
transfer technology for increased efficiency.
Measurements taken at the horizontal air intake.
• RTHD includes standard electrical demand limiting.
• Chilled water reset
Fan
based on return water temperature
Power level in dB(A), per Hz frequency band Overall power
Unit is standard. speed 125 250 500 1000 2000 4000 8000 dB(A)
• High compressor1lift capabilities
56 and tight
55 chilled water
55 53 46 45 42 57
FWD 08temperature control2 63
allow highly 62 system 60
efficient 60 53 53 53 64
3 66 65 63 62 56 55 57 67
design with minimal
1 operational
62 concerns.
58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

UNT-PRC002-GB
RLC-PRC045B-GB 191
Application Considerations
Technical Data
Condenser Water Regulation Condenser water pump with variable frequency drive
The Condenser and Differential pressure options provide Advantages:
2-10Vdc/4-20mA (maximum range -a smaller range is
• P umping cost can be reduced.
adjustable) output interface to the customer’s condenser
• Good tower temperature control.
water
FWD flow device. This option enables the Tracer UC800 08 12 20 30 45
Power supply • Relatively low first cost. 230/1/50
controls to send a signal for opening (V/Ph/Hz)
and closing a
Capacities Disadvantage:
2-way or 3-way valve as necessary to maintain
Cooling capacity on water (1) (kW)
chiller 5,2 8,3 15 18,8 30,1
differential pressure.
Heating capacity on water (2) (kW) 6,3 • Increased rate
11,9 of fouling due
18,9to lower water
20,9 velocity in
38,2
Fan motor
Methods other than those shown can be (type)
employed to the condenser. 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
achieve the same
Current amps (3) results. Contact your local
(A) Trane office
1,1 Figure 3 2,2 3,1 4,7 5,5
for details.
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
Throttling
minimum valve (m3/h) 490 980 1400 1800 2700
nominal (m3/h) 820 1650 2300 3000 4500
This
maximum
method maintains condensing pressure (m3/h)
and 980 1970 2600 3600 5400
temperature
Main coil by throttling water flow leaving the
condenser in response
Water entering/leaving to condenser pressure
connections (type) or system ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
differential pressures.
Electric heater (accessory for blower only)
Advantages:
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 8 10 12 12
• HotGoodwatercontrol with for
coil (accessory proper
blowervalve
only) sizing at relatively low
cost. capacity (4)
Heating (kW) 6,3 1 = Electric or 12 pneumatic valve 17,4actuator 22,4 34,5
• G2Pumping
filter (filter cost
box accessory)
can be reduced. 2A = 3
 -way valve or 2 butterfly valves
Quantity 2 2 2 2 2
Disadvantages:
Dimensions ( LxWxth) (mm) 386x221x8 2B = 2 butterfly valves
486x271x8 586x321x8 586*421*8 586*621*8
• G4
Quantity
filter (filter box accessory)
Increased rate of fouling due to lower condenser water - 3 = RTHD Evo controller
2 2 2 2
velocity.
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
4 = Refrigerant pressure line
• Condensate
Requirespump pumps that can accommodate
(accessory) (type)variable flow. Centrifugal
Water flow - lift height (l/h - mm) 5A = Condenser water pump 24 - 500
Figure
Not available 1 for FWD30 and FWD45
Sound level (L/M/H speed) 5B = C
 ondenser water pump with VFD
Sound pressure level (5) (dB(A)) 36/40/43 6 = To/from cooling
38/41/44 load 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions 7 = To/from cooling tower
Width x Depth (mm) 890 x 600
Height (mm) 250
8 = Electric1090 300
x 710
controller 1290 x 820
350
1290 x 970
450
1290 x 1090
650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Cooling
Unit alonetower (aM/gI) bypass (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25
Tower bypass is also a valid control method if the chiller
temperature requirements
(1) Conditions: Water can be maintained.
entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
Advantage:
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
• (5)EAxcellent
rectangularcontrol
glass woolbyductmaintaining constant
1m50 long is placed watermeasurement
on the blower.The flow is taken in the room containing the blower unit.

Heat through
exchangerthe condenser.
operating limits:
FWD:
Disadvantage:
*water temperature: max 100° C
• *absolute
Higher costpressure:
service because min 1of the dedicated
bar/max 11 bars pump required
for each
Accessories chiller
- Hot if condenser pressure is the control
water coil:
signal.
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Figure 2

4
10 UNT-PRC002-GB
RLC-PRC045B-GB
Application Considerations

Variable Evaporator Flow and Short Evaporator Water Series Chiller Arrangements
Loops Another energy-saving strategy is to design the system
Variable evaporator flow is an energy-saving design around chillers arranged in series, on the evaporator,
strategy which has quickly gained acceptance as condenser, or both. The actual savings possible with such
advances in
Sound power levelschiller and controls technology have made strategies depends on the application dynamics and
it possible. With its linear unloading compressor design should be researched by consulting your Trane Systems
and advanced Tracer UC800 controls, the RTHD Evo Solutions Representative and applying the Trane System
Discharge
has excellent capability to maintain leaving water Analyzer program. It is possible to operate a pair of
temperature control within +/‑ 0.28°C, even for systems chillers more efficiently in a series chiller arrangement
Measurement conditions:
with variable evaporator flow and small chilled water than in a parallel arrangement. It is also possible to
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
volumes. achieve higher entering-to-leaving chiller differentials,
long) fixed to its discharge opening.
Some basic rules should be followed whenever using which may, in turn, provide the opportunity for lower
these system design Fan and operational savings methods chilled water design temperature, lower design
Power level in dB(A), per Hz frequency band
flow, and
Overall power
Unitwith the RTHD Evo. The proper
speed 125location of
250the chilled500 resulting
1000 installation
2000 and operational
4000 cost savings.
8000 dB(A)The
1 55 50
water temperature control sensor is in the supply 42 Trane37 screw compressor
37 also
31 has excellent
30 capabilities
46
FWD 08 2 57 54 47 40
for «lift», which30affords an 38
opportunity40for savings50on the
(outlet) water. This 3location allows
58 the building
57 to act50as 42 32 40 43 53
a buffer, and it assures
1 a slowly57 changing51 return water 45 evaporator
42 and34condenser33 water loops.
28 48
FWDtemperature.
10 2 is insufficient
If there 58 water 54
volume in 48 Like45series arrangements
38 39 the evaporator,
on 35 51
series
3 60 58 50 48 40 42 39 54
the system to provide 1
an adequate
57
buffer,51temperature 45
arrangements
42
on
34
the condenser
33
may enable
28
savings.
48
control
FWD 12 can be lost,2resulting in
58erratic system
54 48 This45approach may
38 allow reductions
39 in35pump and51
operation and excessive3 compressor
60 cycling.
58 To ensure 50 tower
48 installation
40 and operating
42 costs.39Maximizing 54
consistent operation 1 and tight56temperature 62 control, the
50 48 efficiency
system 39 requires 38 36
that the designer 56
balance
FWD 14 2 61 66 55 53 47 46 45 60
chilled water loop should
3 be at
63least 2 minutes.
69 If this
58 performance
56 considerations
50 50 for all system
49 components;
63
recommendation cannot 1 be followed,
57 and63tight leaving51 the 49
best approach
40 may or may
39 not involve
37 multiple
57
FWDwater
20 temperature 2control is necessary,
61 a66storage tank55 53
chillers, 47 arrangement
or series 46 45
of the evaporators 60
and/
3 63 69 58 56 50 50 49 63
or larger header pipe should be installed to increase the or condensers. This ideal balance of design integrity with
volume of water in the system. installation and operating cost considerations can also
Intake
For variable primary flow applications, the rate of chilled be obtained by consulting a Trane representative and
water flow change should not exceed 10% of design applying the Trane System Analyzer program.
Measurement conditions:
Measurements taken at the+/‑ 0.28°C
per minute to maintain horizontalleaving evaporator
air intake. Water Treatment
temperature control.
The use of untreated or improperly treated water
For applications inFan
which system energy Power
savings
levelisinmost
dB(A), per Hz frequency band
in chillers may2000
result in scaling, erosion, Overall power
corrosion,
Unit speed 125 250
important and tight temperature control is classified500 1000
and53 algae or slime
4000 8000 dB(A)
1 56 55 55 46 buildup. 45It is recommended
42 that
57
FWDas08 +/-1.1°C, up to 30%
2 changes63in flow per62minute are60 the 60
services of a53qualified water
53 treatment
53 specialist
64
possible. Flow rates3 should be66maintained 65between 63 62
be engaged 56
to determine 55
what 57
treatment, 67
if any, is
1
the minimum and maximum 62
allowed for 58
any particular 55 58 51 48 44 61
FWD 10 2 66 63 60 advisable.
62 Trane56assumes no 55 responsibility
52 for the66results
chiller configuration.
3 70 67 63 of using
65 untreated
59 or improperly
59 treated
57 water. 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

UNT-PRC002-GB
RLC-PRC045B-GB 11
Application Considerations
Technical Data
Water Pumps
Where noise limitation and vibration-free operation
are important, Trane strongly encourages the use of
1450‑rpm (50 Hz) pumps. Specifying or using 3000-rpm
(50
FWDHz) condenser water and chilled water pumps must 08 12 20 30 45
Power
be supply because such pumps may
avoided, (V/Ph/Hz)
operate with 230/1/50
Capacities
objectionable levels of noise and vibration.
Cooling capacity on water (1) (kW)
In addition,
5,2 8,3 15 18,8 30,1
aHeating
low frequency beat (2)
capacity on water may occur due to(kW)
the slight 6,3 11,9 18,9 20,9 38,2
difference
Fan motor in operating rpm between 3000-rpm(type) (50 Hz) 2 x direct drive centrifugal
Fan power
water input and
pumps (3) chiller motors. (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Important
Start-up amps Note: The chilled water pump(A) must not be 3,2 5,5 9,3 14,1 16,5
Air flow
used to stop the chiller.
minimum (m3/h) 490 980 1400 1800 2700
nominal
Acoustic Considerations (m3/h) 820 1650 2300 3000 4500
maximum (m3/h) 980 1970 2600 3600 5400
Refer to the Engineering Bulletin RLC-PRB006 regarding
Main coil
Sound Data/Installation
Water entering/leaving Guide for Noise-Sensitive
connections (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Applications for Trane water-cooled helical-rotary chillers.
Electric heater (accessory for blower only)
Using the information
Electric power supply provided in this bulletin,
(V/Ph/Hz) contact
230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
aHeating
certified sound consultant to aid in proper
capacity (kW) mechanical 2/4 8 10 12 12
Hot water
room coil (accessory
design for blower only)
and treatment
Heating capacity (4) (kW) 6,3 12 17,4 22,4 34,5
Sound
G2 filter data
(filter given data in accordance with ISO 3746-1996.
box accessory)
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

4
12 UNT-PRC002-GB
RLC-PRC045B-GB
Selection Procedure
Performance
We strongly recommend to our customers to contact,
local Trane Sales Office, to get accurate computer
selection performances at the project operating
conditions.
Sound power levels
Dimensional Drawings
Discharge
The dimensional drawings illustrate overall
measurements of the unit. Also shown are the service
Measurement
clearances conditions:
required to easily service the RTHD Evo
Measurements taken dimensional
chiller. All catalog in a room adjacent to the
drawings are room
subjectcontaining
to the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to
change. its discharge
Current submittalopening.
drawings should be referred
to for detailed dimensional information. Contact the
Fan Power level in dB(A), per Hz frequency band Overall power
Unit
sales office for submittal
speed
information.
125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
Electrical Data Tables
FWD 08 2 57 54 47 40 30 38 40 50
Compressor motor3electrical data 58 is shown 57 in the data
50 42 32 40 43 53
1
section for each compressor 57 Rated load
size. 51 amperes 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
(RLA), locked rotor 3Star-Delta amperes
60 (LRAY),
58 the power
50 48 40 42 39 54
factor for standard 1voltages for 57 all 50 Hz, 51
3‑phase motors
45 42 34 33 28 48
FWDare
12 shown. The RLA 2 is based on58 the performance
54 of 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
the motor developing 1
full rated
56
horsepower.62
A voltage50 48 39 38 36 56
FWDutilization
14 range is 2tabulated for
61 each voltage
66 listed. 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Evaporator and Condenser
1 Pressure
57 Drop63 51 49 40 39 37 57
FWDPressure
20 drop data2is determined61 by the RTHD66 55
selection 53 47 46 45 60
3 63 69 58 56 50 50 49 63
program.
Intake

Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

UNT-PRC002-GB
RLC-PRC045B-GB 11
13
Unit Model Number
Technical Data
Digit 1-2-3-4: Chiller series RTHD Digit 27: Condenser waterside pressure
Digit 5: Factory L: CDS 10 bar
E = Europe H: CDS 21 bar

Digit 6-7: Unit size Digit 28: Condenser leaving water temperature
FWD 08 A: Standard 12 T < or = 45°C20 30 45
B1-B2-C1-C2-D1-D2-D3-E3
Power supply (V/Ph/Hz) 230/1/50
Capacities
B: HI 45 < T < or = 50°C
Digit 8: Main power voltage
Cooling capacity on water (1) (kW) 5,2 8,3 15 18,8 30,1
R: 380V/50Hz/3Ph
Heating +/-5%
capacity on water (2) (kW) 6,3
Digit 29: Refrigerant
11,9
specialties18,9 20,9 38,2
T:Fan
400V/50Hz/3Ph
motor +/-10% (type) X: Without 2 x direct drive centrifugal
Fan power input (3)
U: 415V/50Hz/3Ph +/-5% (kW) 0,23 G: Gauges 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2
V: Isolation valves 3,1 4,7 5,5
Start-up
Digit 9: amps
Special order (A) 3,2 5,5 9,3 14,1 16,5
Air flow B: V+G
X: Standard Configuration
minimum (m3/h) 490 980 1400 1800 2700
S: Special order feature
nominal (m3/h) 820 Digit 30: Oil cooler
1650 2300 3000 4500
maximum (m3/h) 980 X: Without 1970 2600 3600 5400
Digit 10-11: Design Sequence
Main coil C: With
LWater
= L0entering/leaving connections (type) ISO R7 rotating female
(Dia) 3/4" Digit 31: Thermal
3/4" insulation 1 1/2" 1 1/2" 1 1/2"
Digit 12heater
Electric : Agency listing
(accessory for blower only)
X: Without
CElectric
= CE power
Listingsupply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50
Q: Cold parts 8
400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 10 12 12
Hot water coil (accessory for blower only)
Digit 13: Pressure vessel approval Digit 32: Sound
Heating capacity (4) (kW) 6,3 12Attenuator 17,4 22,4 34,5
P:
G2PED
filter (Pressure equipment directive)
(filter box accessory) X = Without
S: Special
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 Digit 33: Documentation
486x271x8 language
586x321x8 586*421*8 586*621*8
Digit 14-15:
G4 filter (filter Evaporator
box accessory)size C: Spanish
Quantity
B1-C1-D1-D2-D3-D4-D5-D6-E1-F1-F2-G1-G2-G3 - 2 2 2 2
Dimensions ( LxWxth) (mm) -
D: German486x264x48 586x314x48 586*414*48 586*614*48
Digit 17: Evaporator
Condensate water passes
pump (accessory) (type) E: English Centrifugal
Water flow - lift height
2: 2 passes (l/h - mm) F: French 24 - 500
Not available for FWD30 and FWD45 H: Dutch
3: 3 passes
Sound level (L/M/H speed)
4: 4 passes
Sound pressure level (5) (dB(A)) 36/40/43 I: Italian 38/41/44 46/50/53 47/52/57 47/52/58
Sound
6: power level (5)
6 passes (dB(A)) 46/50/53 M: Swedish48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions P: Polish
Width18:x Depth
Evaporator water connection (mm) 890 x 600
Digit
Height (mm) 250
R = Russian1090300x 710 1290 x 820
350
1290 x 970
450
1290 x 1090
650
L: Left hand
Shipped unit dimensions T: Czech
R: Right
Width hand
x Depth (mm) 933 x 644 U: Greek 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 V: Portuguese310 360 460 660
Digit
Weight19: Evaporator connection type (kg) 32 46 61 76 118
A: standard grooved pipes
Colour 6 = Hungarian galvanised steel
Recommended
B: grooved pipes fuse size
+ coupling 8 = Turkish
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with
Digit 20:electric heater (gI)
Evaporator waterside pressure(A) Digit
16 (2kW),25 (4kW) 34: Safety devices
40 (230V),3*16 (400V) 3*20 3*25 3*25
L: X: Standard
(1)EVP 10 bar
Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
H:
(2) EVP 21 bar
Conditions: B:- Dual
Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB Nominalsafety
air flow valves
(3) At high speed with nominal air flow. A: B + rupture disc
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
Digit 21-22: Condenser
(5) A rectangular size long is placed on the blower.The measurement is taken in the room containing the blower unit.
glass wool duct 1m50
B1-D1-E1-E2-E3-E4-E5-F1-F2-F3-G1-G2-G3 Digit 35: Refrigerant charge
Heat exchanger operating limits: A: Full factory charge (R134a)
FWD:
Digit 23: Condenser
*water temperature: max 100° C
tube type B: Nitrogen (No oil)
A: Enhanced
*absolute fin - copper
service pressure: min 1 bar/max 11 bars C: Holding charge (R134a)
B: Smooth bore - copper
Accessories - Hot water coil:
C: Smooth
*water bore
temperature: - 90/10
min. Cu/Ni
+2° C/max. 100° C
Digit 36: Shipping package
*absolute service pressure: min 1 bar/max 11 bars A: Domestic
Digit 24: Condenser water passes E: SEI class 3
2: 2 passes F: SEI class 4a
Digit 25: Condenser water connection G: SEI class 4c
L: Left hand Digit 37: Flow switch
R: Right hand X: Without
Digit 26: Condenser connection type A: Evaporator
A: Standard grooved pipes B: Evaporator + condenser
B: Standard grooved pipes + coupling

4
14 UNT-PRC002-GB
RLC-PRC045B-GB
Unit Model Number

Digit 38: Factory test Digit 53 : Regulation valve & RLA


A: Functional test X : Without
B: Customer inspection D: Chiller differential pressure & RLA out
C: Witness test P: condenser pressure (%HPC) & RLA out
D: Performance test with report V: With
Sound power levels
X : Without
Digit 54: Refrigerant Monitor Input
Digit 39: Starter type
Discharge X: without
B: AFD (Adaptive Frequency Drive) A: 100 ppm/4-20 mA
C: AFD + AHF
Measurement (Adaptive Frequency Drive + Advanced
conditions: B: 1000 ppm/4-20mA
Harmonic Filters)
Measurements taken in a room adjacent to the room containingC:the
100FWD,
ppm/2-10Vdc
at the outlet of the rectangular duct (1.5 m
Y: Star-delta closed transition starter
long) fixed to its discharge opening. D: 1000 ppm/2-10Vdc
Digit 40-41-42: Motor RLA
Fan Power level in dB(A), per Hz frequency band Overall power
Unit
233: Amperes speed 125 250 500 1000 2000 4000 8000 dB(A)
349: Amperes 1 55 50 42 37 37 31 30 46
FWD455:
08 Amperes 2 57 54 47 40 30 38 40 50
488: Amperes 3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWDDigit
10 43: Power line2 connection58type 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
A: Terminal block 1 57 51 45 42 34 33 28 48
FWDB:
12Disconnect switch 2 (No fuses)
58 54 48 45 38 39 35 51
D: Circuit breaker 3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
K: Disconnect switch and fuses
FWD 14 2 61 66 55 53 47 46 45 60
3
Digit 44: Electrical protection 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWDB:
20Dead Front 2 61 66 55 53 47 46 45 60
D: IP20 electrical protection
3 63 69 58 56 50 50 49 63

Digit 45: Electrical protection


Intake
X: No accessory
U: Under/over voltage protection
Measurement conditions:
G: Ground fault protection relay (SE/HE/XE versions only)
Measurements taken at the horizontal air intake.
B: U+G
Digit 46: ControllerFan
Operator Interface Power level in dB(A), per Hz frequency band Overall power
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
T: TD7 / All languages
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
Digit 47: Remote interface
3 66 65 63 62 56 55 57 67
X: Without 1 62 58 55 58 51 48 44 61
FWD4:
10Tracer COMM 4 2 66 63 60 62 56 55 52 66
3
5: Tracer COMM 5 LCI-C 70
(LonTalk) 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
6:
FWD 12Unit level BACnet
2 Interface 66 63 60 62 56 55 52 66
7: Unit level Modbus
3 Interface70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWDDigit
14 48: External chilled
2 water73+ current limit
72 setpoint 69 71 64 59 57 74
X: Without 3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
4:
FWD 20
4-20mA input 2 76 76 68 71 65 61 61 75
2: 2-10Vdc input 3 78 79 71 74 69 66 66 78

Digit 49: External base loading


X: Without
4: 4-20mA input
2: 2-10Vdc input
Digit 50: Ice making
X: Without
A: Ice making with relay
B: Ice making without relay
Digit 51: Programmable relays
R: Programmable relays
Digit 52: Chilled water reset
X: Standard
T: Chilled water reset - outdoor air temperature

UNT-PRC002-GB
RLC-PRC045B-GB 11
15
General Data
Technical Data
Table 1 – General data
RTHD Standard Efficiency (SE) RTHD C1 D6 E5 RTHD C2 D6 E5 RTHD D1 D4 E4 RTHD D2 D1 E1 RTHD D3 D1 E1 RTHD E3 D2 E2
RTHD 225 SE RTHD 250 SE RTHD 300 SE RTHD 325 SE RTHD 350 SE RTHD 375 SE
Gross Cooling Capacity (1) (kW) 772 890.7 1055 1151 1222 1349
Gross EER (1) 5.46 5.38 5.38 5.50 5.40 5.12
FWD Gross ESEER (Not certified) (1) 6.18
08 6.32 12 5.92 206.20 306.16 455.67
Power IPLV (2)
supply (V/Ph/Hz) 6.540 6.680 6.380 6.660
230/1/50 6.530 6.060
Net cooling capacity (1) (3)
Capacities (kW) 769 886 1049 1145 1216 1342
Net capacity
Cooling EER (1) (3) on water (1) (kW) 5.16
5,2 5.03 8,3 5.03 155.18 5.06
18,8 4.81
30,1
Eurovent
Heating capacityEnergy class -(2)
on water Cooling (kW) A
6,3 B 11,9 B 18,9 A 20,9A 38,2 B
Net
Fan motor ESEER (3) (type) 5.41 5.36 5.09
2 x direct drive5.41
centrifugal 5.31 4.93
SEER (6)
Fan power input (3) (kW) 5.88
0,23 6.00 0,46 5.43 0,655.73 5.75
1,04 5.18
1,51
Space
Current amps cooling
(3) efficiency ηs,c (4) (A) % 227
1,1 232 2,2 209 3,1221 222
4,7 5,5199
Mainamps
Start-up Power Supply (A) V/Ph/Hz 400/3/50
3,2 400/3/50 5,5 400/3/50 400/3/50
9,3 400/3/50
14,1 400/3/50
16,5
Sound Power Level
Air flow (dB(A)) 80 80 78 78 78 82
Unit amps
minimum (m3/h) 490 980 1400 1800 2700
Unit rated amps
nominal (m3/h)(A) 349
820 349 1650 455 2300455 455
3000 488
4500
Unit start up amps
maximum (m3/h)(A) 480
980 480 1970 748 2600748 748
3600 748
5400
Main Power
coil factor 0.87 0.87 0.89 0.89 0.89 0.89
WaterFuse
entering/leaving
size connections (type)(A) 400 400 630ISO R7 rotating
630female 630 630
Disconnect switch size (Dia)(A) 3/4"
400 400 3/4" 630 1 1/2"
630 1 1/2"
630 1 1/2"
630
Electric heater
Short Circuit(accessory for blower only)
Unit Capacity (kA) 35 35 35 35 35 35
Electric power supply
Compressor (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacitycode
Compressor (kW) 2/4
C1 C2 8 D1 10 D2 12D3 12 E3
Hot water
Oil sumpcoilHeater
(accessory for blower only) (W) 300 300 300 300 300 300
Heating
Evaporatorcapacity (4) (kW) 6,3 12 17,4 22,4 34,5
G2 filter (filter box
Evaporator codeaccessory) D6 D6 D4 D1 D1 D2
Quantity
Evaporator Water Content (l) 2
193 193 2 220 2 248 2248 2 265
Dimensions
Two pass( LxWxth)
evaporator (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter
Evap. boxFlow
Water accessory)
rate - Minimum (l/s) 23 23 27 32 32 35
Quantity
Evap. Water Flow rate - Maximum (l/s) -
81 81 2 97 2 114 2114 2 124
Dimensions
Nominal( LxWxth)
water connection size (Grooved (mm)(mm)
coupling) -
200 200 486x264x48
200 586x314x48
200 586*414*48
200 586*614*48
200
Condensate
Three pass pump (accessory)
evaporator (type) Centrifugal
WaterEvap.
flow -Water
lift height
Flow rate - Minimum (l/h - mm)
(l/s) 15 15 18 24 - 500
21 21 23
Not available
Evap. Water for FWD30
Flow rateand FWD45
- Maximum (l/s) 54 54 64 76 76 83
SoundNominal
level (L/M/H speed)
water connection size (Grooved coupling) (mm) 200 200 200 200 200 200
Sound pressure
Four level (5)
pass evaporator (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
SoundEvap.
power level (5)
Water Flow rate - Minimum (dB(A))
(l/s) 46/50/53
12 12 48/51/54 14 56/60/63
16 57/62/67
16 57/62/68
18
Unit dimensions
Evap. Water Flow rate - Maximum (l/s) 40 40 48 57 57 62
WidthNominal
x Depthwater connection size (Grooved (mm)(mm)
coupling) 890 150
x 600 150 1090 x 710150 1290 x 150
820 1290 x 970
150 1290 x 1090
150
HeightSix pass evaporator (mm) 250 300 350 450 650
ShippedEvap.unit dimensions
Water Flow rate - Minimum (l/s) - - - - - -
WidthEvap.
x Depth Water Flow rate - Maximum (mm)(l/s) 933 x- 644 - 1133 x 754 - 1333 x 864
- 1333 x 1008
- 1333*1133
-
HeightNominal water connection size (Grooved (mm)(mm)
coupling) 260
- - 310 - 360 - 460- 660 -
Weight (kg) 32 46 61 76 118
Colour
Condenser galvanised steel
Recommended fuse size
Condenser code E5 E5 E4 E1 E1 E2
Unit alone (aM/gI)
Condenser Water Content (A) (l) 8/16
132 135 8/16 148 8/16167 8/25
167 8/25178
Unit with electricWater
Condenser heater (gI)rate - Minimum
Flow (A) (l/s) 16 (2kW),25
16 (4kW) 40
16 (230V),3*16 (400V)
19 3*2022 3*25
22 3*2524
Condenser Water Flow rate - Maximum (l/s) 57 57 67 80 80 87
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
NominalWater
(2) Conditions: waterentering/leaving
connection sizetemperature:
(Grooved coupling) (mm)
50/45 °C, Air 20020°C DB - Nominal
inlet temperature 200air flow 200 200 200 200
Dimensions
(3) At high speed with nominal air flow.
Width
(4) Water (mm) 20 °C DB,1600
entering/leaving temperature 90/70 °C, air inlet temperature Nominal air flow. 1600 1600 1600 1600 1600
(5) A rectangular
Length glass wool duct 1m50 long is placed on the blower.The
(mm) measurement
3290 is taken in3290
the room containing
3290the blower unit.3290 3290 3290
Height (mm) 1940 1940 1940 1940 1940 1940
Heat exchanger operating limits:
Shipping weight (kg) 5570 6300 5970 6110 6140 6250
FWD:
*waterOperating weight
temperature: max 100° C (kg) 5891 6833 6335 6522 6553 6655
System service
*absolute data pressure: min 1 bar/max 11 bars
Refrigerant circuit 1 1 1 1 1 1
Accessories
R134a- refrigerant
Hot water coil:
charge (kg) 217 217 211 211 211 211
*water temperature: min. +2° C/max. 100° C
Oil charge (l) 23.0 23.0 23.0 23.0 23.0 23.0
*absolute service pressure: min 1 bar/max 11 bars
POE Oil type OIL048E or OIL023E

(1) E vaporator 12/7°C and 0.0 m²K/kW, and condenser at 30/35°C and 0.0 m²K/kW.
(2) According to AHRI Standard 550/590, based on TOPSS (Trane Official Product Selection Software).
(3) N et performances calculated as per EN 14511-2013.
(4) η s,c / SEER as defined in Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for Comfort
Chillers with 2000 kW maximum capacity - COMMISSION REGULATION (EU) N° 2016/2281 of 20 December 2016.
(5) At full load and in accordance with ISO9614.
(6) Inrush current in star/delta connection.

4
16 UNT-PRC002-GB
RLC-PRC045B-GB
General Data

Table 2 – General data


RTHD B1 RTHD B2 RTHD C1 RTHD C2 RTHD D1 RTHD D2 RTHD D3 RTHD E3
RTHD High Efficiency unit (HE)
B1 B1 B1 B1 D5 E4 D5 E4 D3 E3 F1 F2 F1 F2 F2 F3
RTHD RTHD RTHD RTHD RTHD RTHD RTHD RTHD
150 HE 175 HE 225 HE 250 HE 300 HE 350 HE 375 HE 400 HE
Gross Cooling Capacity (1) (kW) 547 597 781 900 1077 1200 1283 1417
SoundGross
power
EER (1) levels 5.73 5.70 5.62 5.56 5.66 5.96 5.93 5.62
Gross ESEER (Not certified) (1) 6.39 6.61 6.34 6.49 6.22 6.63 6.59 6.10
IPLV (2) 6.780 6.940 6.700 6.860 6.700 7.120 6.970 6.520
DischargeNet cooling capacity (1) (3) (kW) 545 595 778 896 1074 1196 1278 1411
Net EER (1) (3) 5.49 5.43 5.36 5.26 5.42 5.65 5.6 5.31
Measurement
Eurovent conditions:
Energy class - Cooling A A A A A A A A
Net ESEER (3) 5.79 5.88 5.68 5.66 5.63 5.88 5.78 5.38
Measurements
SEER (6)
taken in a room adjacent to the room containing
6.04
the
6.33
FWD,6.02
at the outlet
6.21
of the
5.77
rectangular
6.14
duct
6.22
(1.5 m
5.59
long) fixed
Spacetocooling
its discharge opening.
efficiency ηs,c (4) % 233 245 233 241 223 238 241 215
Main Power Supply V/Ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
Sound Power LevelFan (dB(A))
Power 80
level in dB(A), 80 frequency
per Hz 80band 80 78 78 78 82
Overall power
Unit Unit amps speed 125 250 500 1000 2000 4000 8000 dB(A)
Unit rated amps 1 55 50(A) 233
42 233 37 349 37 349 455
31 455 30 455 46 488
FWD 08 Unit start up amps 2 57 54(A) 412
47 412 40 480 30 480 748
38 748 40 748 50 748
Power factor 3 58 57 0.90
50 0.90 42 0.87 32 0.87 0.89
40 0.89 43 0.89 53 0.89
Fuse size 1 57 51(A) 315
45 315 42 400 34 400 630
33 630 28 630 48 630
FWD 10 Disconnect switch size 2 58 54(A) 315
48 315 45 400 38 400 630
39 630 35 630 51 630
Short Circuit Unit Capacity
3 60 58(kA) 35
50 35 48 35 40 35 35
42 35 39 35 54 35
Compressor 1 57 51 45 42 34 33 28 48
FWD 12 Compressor code 2 58 54 B1
48 B2 45 C1 38 C2 D1
39 D2 35 D3 51 E3
Oil sump Heater 3 60 58(W) 300
50 300 48 300 40 300 300
42 300 39 300 54 300
Evaporator 1 56 62 50 48 39 38 36 56
FWD 14 Evaporator code 2 61 66 55
B1 B1 53 D5 47 D5 46
D3 F1 45 F1 60 F2
3
Evaporator Water Content 63 69(l) 58
168 168 56 220 50 220 50
281 394 49 394 63 417
Two pass evaporator1 57 63 51 49 40 39 37 57
FWD 20 Evap. Water Flow rate2 - Minimum 61 66(l/s) 55
19 19 53 27 47 27 46
37 43 45 43 60 46
Evap. Water Flow rate3 - Maximum 63 69(l/s) 58
69 69 56 97 50 97 50
134 156 49 156 63 168
Nominal water connection size (Grooved coupling) (mm) 200 200 200 200 200 250 250 250

Intake Three pass evaporator


Evap. Water Flow rate - Minimum (l/s) 13 13 18 18 25 29 29 31
Evap. Water Flow rate - Maximum (l/s) 46 46 64 64 89 104 104 112
Measurement
Nominal conditions:
water connection size (Grooved coupling) (mm) 150 150 200 200 200 200 200 200
Measurements taken at the horizontal air intake.
Four pass evaporator
Evap. Water Flow rate - Minimum (l/s) 10 10 14 14 18 22 22 23
Evap. Water Flow rate - Maximum (l/s) 34 34 48 48 67 78 78 84
Fan Power level in 100
Nominal water connection size (Grooved coupling) (mm)
dB(A), per 100
Hz frequency
150
band 150 150 150
Overall power
150 150
Unit Six pass evaporator
speed 125 250 500 1000 2000 4000 8000 dB(A)
1
Evap. Water Flow rate - Minimum
56 55(l/s) 55
- -
53 -
46 - 45- -
42 -
57 -
FWD 08 Evap. Water Flow rate 2 - Maximum 63 62(l/s) 60
- -
60 -
53 - 53- -
53 -
64 -
3 66 65 63 62 56 55 57 67
Nominal water connection size (Grooved coupling) (mm) - - - - - - - -
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
Condenser
3 70 67 63 65 59 59 57 69
Condenser code B1 B1 E4 E4 E3 F2 F2 F3
1 62 58 55 58 51 48 44 61
Condenser Water Content (l) 106 106 148 148 181 224 224 240
FWD 12 2 66 63 60 62 56 55 52 66
Condenser Water Flow rate - Minimum (l/s) 15 15 19 19 25 27 27 30
3 70 67 63 65 59 59 57 69
Condenser Water Flow rate - Maximum (l/s) 53 53 67 67 89 97 97 106
1 66 65 65 65 57 50 46 68
Nominal water connection size (Grooved coupling) (mm) 150 150 200 200 200 200 200 200
FWD 14 2 73 72 69 71 64 59 57 74
Dimensions
3 78 76 73 75 69 64 63 78
Width (mm) 1600 1600 1600 1600 1600 1600 1600 1600
1 68 72 64 64 56 52 50 69
Length (mm) 3170 3170 3290 3290 3290 3690 3690 3690
FWD 20 2 76 76 68 71 65 61 61 75
Height (mm) 1850 1850 1940 1940 1940 1940 1940 1940
3 78 79 71 74 69 66 66 78
Shipping weight (kg) 4090 4090 5670 5670 6150 6940 6980 7120
Operating weight (kg) 4361 4361 6030 6030 6612 7558 7589 7767
System data
Refrigerant circuit 1 1 1 1 1 1 1 1
R134a refrigerant charge (kg) 182 182 217 217 211 278 278 278
Oil charge (l) 17.0 17.0 23.0 23.0 23.0 38.0 38.0 38.0
POE Oil type OIL048E or OIL023E

(1) Evaporator 12/7°C and 0.0 m²K/kW, and condenser at 30/35°C and 0.0 m²K/kW.
(2) According to AHRI Standard 550/590, based on TOPSS (Trane Official Product Selection Software).
(3) Net performances calculated as per EN 14511-2013.
(4) η s,c / SEER as defined in Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for Comfort
Chillers with 2000 kW maximum capacity - COMMISSION REGULATION (EU) N° 2016/2281 of 20 December 2016.
(5) At full load and in accordance with ISO9614.
(6) Inrush current in star/delta connection.

UNT-PRC002-GB
RLC-PRC045B-GB 11
17
General Data
Technical Data
Table 3 – General data
RTHD B1 RTHD B2 RTHD C1 RTHD C2 RTHD D1 RTHD D2 RTHD D3 RTHD E3
RTHD Extra High Efficiency unit (XE)
C1 D1 C1 D1 D3 E3 E1 F1 G1 G1 G1 G1 G2 G2 G3 G3
RTHD RTHD RTHD RTHD RTHD RTHD RTHD RTHD
150 XE 175 XE 225 XE 275 XE 325 XE 350 XE 375 XE 425 XE
FWD Gross Cooling Capacity (1) (kW) 56108 616 799 12 940 112120 1206 1297
30 1456
45
Power Gross
supplyEER (1) (V/Ph/Hz) 5.95 5.98 5.85 6.11 6.15
230/1/50 6.10 6.15 5.93
Gross ESEER (Not certified) (1)
Capacities 6.58 6.88 6.55 6.93 6.65 6.75 6.73 6.36
IPLVcapacity
Cooling (2) on water (1) (kW) 6.980
5,2 7.220 6.920 8,3 7.320 7.16015 7.230 7.100
18,8 6.800
30,1
Net capacity
Heating cooling capacity
on water(1)(2)
(3) (kW) (kW) 5596,3 614 797 11,9 937 1119 18,9 1203 1294
20,9 1453
38,2
Net
Fan motor EER (1) (3) (type) 5.69 5.69 5.68 5.86 5.94
2 x direct 5.88
drive centrifugal 5.94 5.73
Eurovent
Fan power Energy
input (3) class - Cooling (kW) A0,23 A A 0,46 A A 0,65 A 1,04A A1,51
Netamps
Current ESEER(3) (3) (A) 5.95
1,1 6.09 6.09 2,2 6.27 6.163,1 6.21 6.21
4,7 5.91
5,5
SEER
Start-up (6)
amps (A) 6.16
3,2 6.62 6.47 5,5 6.73 6.289,3 6.36 6.48
14,1 5.96
16,5
Space cooling efficiency ηs,c (4)
Air flow % 239 257 251 261 243 246 251 230
Main Power Supply
minimum (m3/h)V/Ph/Hz 400/3/50
490 400/3/50 400/3/50980400/3/50 400/3/50 1400 400/3/50 400/3/50
1800 400/3/50
2700
Sound Power Level
nominal (m3/h)(dB(A)) 80
820 80 80 1650 80 782300 78 78
3000 82
4500
Unit amps
maximum (m3/h) 980 1970 2600 3600 5400
Main Unit
coil rated amps (A) 233 233 349 349 455 455 455 488
WaterUnit
entering/leaving
start up amps connections (type)(A) 412 412 480 480 ISO R7748
rotating female
748 748 748
Power factor (Dia) 3/4"
0.90 0.90 0.87 3/4" 0.87 1 1/2" 0.89
0.89 1 1/2"
0.89 1 1/2"
0.89
Electric
Fuseheater
size (accessory for blower only) (A) 315 315 400 400 630 630 630 630
Electric power supply
Disconnect switch size (V/Ph/Hz)(A) 230/1/50
315 315 230/1/50
400 or 400/3/50
400 400/3/50 630
630 400/3/50
630 400/3/50
630
Heating
Shortcapacity
Circuit Unit Capacity (kW) (kA) 352/4 35 35 8 35 35 10 35 1235 3512
Hot water coil (accessory for blower only)
Compressor
Heating capacitycode
Compressor (4) (kW) B16,3 B2 C1 12 C2 D1 17,4 D2 22,4
D3 34,5
E3
G2 filter (filterHeater
Oil sump box accessory) (W) 300 300 300 300 300 300 300 300
Quantity
Evaporator 2 2 2 2 2
Dimensions
Evaporator( LxWxth)
code (mm) 386x221x8
C1 C1 D3486x271x8
E1 586x321x8
G1 G2 586*421*8
G2 586*621*8
G3
G4 filter (filter box
Evaporator Wateraccessory)
Content (l) 225 225 281 300 563 597 597 656
Quantity
Two pass evaporator - 2 2 2 2
Dimensions ( LxWxth)
Evap. Water Flow rate - Minimum (mm)(l/s) 25 - 25 486x264x48
37 35 586x314x48
- - 586*414*48
- 586*614*48
-
Condensate pumpFlow
Evap. Water (accessory)
rate - Maximum (type)(l/s) 88 88 134 124 Centrifugal
- - - -
WaterNominal
flow - lift height
water (l/h - mm)
connection size (Grooved coupling) (mm) 200 200 200 200 24
- - 500 - - -
Not available
Three pass forevaporator
FWD30 and FWD45
SoundEvap.
levelWater
(L/M/H speed)
Flow rate - Minimum (l/s) 17 17 25 23 39 42 42 47
SoundEvap.
pressure
Waterlevel
Flow (5)
rate - Maximum (dB(A)) (l/s) 36/40/43
59 59 89 38/41/4483 46/50/53
140 152 47/52/57
152 47/52/58
172
SoundNominal
power water
level (5) (dB(A))
connection size (Grooved coupling) (mm) 46/50/53
150 150 200 48/51/54
200 56/60/63
250 250 57/62/67
250 57/62/68
250
Unit dimensions
Four pass evaporator
WidthEvap.
x DepthWater Flow rate - Minimum (mm)(l/s) 890
13x 600 13 181090 x 710
18 1290
29 x 820 32 1290 x32970 1290
36 x 1090
HeightEvap. Water Flow rate - Maximum (mm)(l/s) 250
44 44 67 300 62 105350 114 450
114 650
129
Shipped unit dimensions
Nominal water connection size (Grooved coupling) (mm) 100 100 150 150 200 200 200 200
WidthSixx Depth
pass evaporator (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
HeightEvap. Water Flow rate - Minimum (mm)(l/s) -260 - - 310 - 20 360 21 46021 24660
Weight Evap. Water Flow rate - Maximum (kg) (l/s) - 32 - - 46 - 70 61 76 7676 86118
ColourNominal water connection size (Grooved coupling) (mm) - - - - galvanised
150 steel
150 150 150
Recommended fuse size
Unit alone (aM/gI)
Condenser (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric
Condenser heater (gI)
code (A) 16 (2kW),25
D1 (4kW)
D1 40 (230V),3*16
E3 (400V)
F1 G13*20 G1 3*25
G2 3*25
G3
Condenser Water Content (l) 125 125 181 235 321 321 370 400
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
Condenser
(2) Conditions: Water
Water Flow rate - Minimum
entering/leaving temperature: 50/45 °C, Air(l/s) 15 20°C DB15
inlet temperature 25flow
- Nominal air 29 34 34 41 45
Condenser
(3) At high Water
speed with Flow rate
nominal - Maximum
air flow. (l/s) 53 53 89 104 123 123 148 163
Nominal
(4) Water water connection
entering/leaving size 90/70
temperature (Grooved
°C, aircoupling) (mm) 20 °C DB,
inlet temperature 150Nominal air
150 flow. 200 200 200 200 200 200
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Dimensions
Width (mm) 1600 1600 1600 1600 1800 1800 1800 1800
Heat exchanger operating limits:
FWD: Length (mm) 3640 3640 3290 3670 3850 3850 3850 3850
*waterHeight
temperature: max 100° C (mm) 1850 1850 1940 1940 2035 2040 2040 2040
Shipping
*absolute weight
service pressure: min 1 bar/max 11 bars (kg) 4410 4410 5900 6300 8070 8280 8420 8690
Operating weight (kg) 4756 4756 6355 6833 8951 9196 9384 9741
Accessories
System data - Hot water coil:
*water temperature: min. +2° C/max. 100° C
Refrigerant circuit 1 1 1 1 1 1 1 1
*absolute service pressure: min 1 bar/max 11 bars
R134a refrigerant charge (kg) 217 217 217 233 311 311 311 319
Oil charge (l) 17.0 17.0 23.0 38.0 42.0 42.0 42.0 42.0
POE Oil type OIL048E or OIL023E

(1) E vaporator 12/7°C and 0.0 m²K/kW, and condenser at 30/35°C and 0.0 m²K/kW.
(2) According to AHRI Standard 550/590, based on TOPSS (Trane Official Product Selection Software).
(3) N et performances calculated as per EN 14511-2013.
(4) η s,c / SEER as defined in Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for Comfort
Chillers with 2000 kW maximum capacity - COMMISSION REGULATION (EU) N° 2016/2281 of 20 December 2016.
(5) At full load and in accordance with ISO9614.
(6) Inrush current in star/delta connection.

4
18 UNT-PRC002-GB
RLC-PRC045B-GB
General Data

Table 4 – General data


RTHD B1 RTHD B2 RTHD C1 RTHD C2 RTHD D1 RTHD D2 RTHD D3 RTHD E3
RTHD High Seasonal Efficiency unit (HSE) C1 D1 C1 D1 D3 E3 E1 F1 G1 G1 G1 G1 G2 G2 G3 G3
w/AFD w/AFD w/AFD w/AFD w/AFD w/AFD w/AFD w/AFD
RTHD RTHD RTHD RTHD RTHD RTHD RTHD RTHD
150 HSE 175 HSE 225 HSE 275 HSE 325 HSE 350 HSE 375 HSE 425 HSE
SoundGross
power levels
Cooling Capacity (1) (kW) 561 616 799 940 1121 1206 1297 1456
Gross EER (1) 5.75 5.78 5.66 5.91 5.95 5.90 5.95 5.74
Gross ESEER (Not certified) (1) 8.10 8.32 8.02 8.65 8.58 8.43 8.88 8.73
DischargeIPLV (2) 8.370 8.680 8.250 8.970 8.850 8.650 9.130 9.090
Net cooling capacity (1) (3) (kW) 559 614 797 937 1119 1203 1294 1453
Measurement conditions:
Net EER (1) (3) 5.51 5.50 5.50 5.67 5.75 5.69 5.75 5.55
Eurovent Energy class - Cooling A A A A A A A A
Measurements taken
Net ESEER (3)
in a room adjacent to the room containing
7.13
the
7.19
FWD,7.31
at the outlet
7.61
of the
7.71
rectangular
7.52
duct
7.94
(1.5 m
7.82
long) fixed
SEERto(4)its discharge opening. 7.72 7.93 7.77 8.45 8.60 8.07 8.82 8.27
Space cooling efficiency ηs,c (4) % 301 309 303 330 336 315 345 323
Main Power SupplyFan V/Ph/Hz
Power level 400/3/50 400/3/50
in dB(A), per 400/3/50
Hz frequency band 400/3/50 400/3/50 400/3/50 400/3/50 Overall400/3/50
power
Unit Sound Power Level speed 125 250(dB(A)) 80
500 801000 80 2000 80 78
4000 788000 78 dB(A)82
Unit amps 1 55 50 42 37 37 31 30 46
FWD 08 Unit rated amps (2) 2 57 54(A) 218
47 218 40 314 30 314 421
38 421 40 421 50 452
Unit start up amps (2)
3 58 57(A) < I50Max. < I Max.42 < I Max. 32 < I Max. < I40
Max. < I Max.43 < I Max. 53 < I Max.
Power factor 1 57 51 0.98
45 0.98 42 0.98 34 0.98 0.98
33 0.98 28 0.98 48 0.98
FWD 10 Fuse size (3) 2 58 54(A) 250T2
48 250T245 400T2 38400T2 500T3
39 500T335 500T3 51500T3
Disconnect switch size
3 (3) 60 58(A) 315
50 315 48 500 40 500 630
42 630 39 630 54 630
Short Circuit Unit Capacity
1 57 51(kA) 35
45 35 42 35 34 35 35
33 35 28 35 48 35
Compressor
FWD 12 2 58 54 48 45 38 39 35 51
Compressor code 3 60 58 B1
50 B2 48 C1 40 C2 D1
42 D2 39 D3 54 E3
Oil sump Heater 1 56 62(W) 50
300 300 48 300 39 300 38
300 300 36 300 56 300
FWD 14 Variable frequency drive
2 size 61 66(kVA) 55
132 132 53 200 47 200 46
250 250 45 250 60 315
Harmonic filter (option) 3 63 69 58 56 50 50 49 63
Harmonic filter size 1 57 63(A) 51
- - 49 - 40 - 39
- - 37 - 57 -
FWD 20 Harmonic filter weight 2 61 66(kg) 55
- - 53 - 47 - 46
- - 45 - 60 -
3
Harmonic filter dimension 63
(H x L x W) 69(mm) 58
- - 56 - 50 - 50
- - 49 - 63 -
Evaporator

Intake Evaporator code C1 C1 D3 E1 G1 G2 G2 G3


Evaporator Water Content (l) 225 225 281 300 563 597 597 656
Two pass evaporator
Measurement conditions:
Evap. Water Flow rate - Minimum (l/s) 25 25 37 35 - - - -
Measurements
Evap. Watertaken at the
Flow rate horizontal air intake.
- Maximum (l/s) 88 88 134 124 - - - -
Nominal water connection size (Grooved coupling) (mm) 200 200 200 200 - - - -
Three pass evaporator
Fan
Evap. Water Flow rate - Minimum
Power
(l/s)
level in dB(A),
17
per Hz
17
frequency
25
band 23 39 42 42
Overall power
47
Unit speed
Evap. Water Flow rate - Maximum
125 250(l/s)
500
59 59
1000 89
2000 83 4000
140 152
8000 152
dB(A)172
1 56 55
Nominal water connection size (Grooved coupling) (mm)
55
150 150
53 200
46 200
45
250 250
42 250
57 250
FWD 08 Four pass evaporator2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
Evap. Water Flow rate - Minimum (l/s) 13 13 18 18 29 32 32 36
1 62 58 55 58 51 48 44 61
Evap. Water Flow rate - Maximum (l/s) 44 44 67 62 105 114 114 129
FWD 10 2 66 63 60 62 56 55 52 66
Nominal water connection size (Grooved coupling) (mm) 100 100 150 150 200 200 200 200
3 70 67 63 65 59 59 57 69
Six pass evaporator
1 62 58 55 58 51 48 44 61
Evap. Water Flow rate - Minimum (l/s) - - - - 20 21 21 24
FWD 12 2 66 63 60 62 56 55 52 66
Evap. Water Flow rate - Maximum (l/s) - - - - 70 76 76 86
3 70 67 63 65 59 59 57 69
Nominal water connection size (Grooved coupling) (mm) - - - - 150 150 150 150
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
Condenser
3 78 76 73 75 69 64 63 78
Condenser code D1 D1 E3 F1 G1 G1 G2 G3
1 68 72 64 64 56 52 50 69
Width (l) 125 125 181 235 321 321 370 400
FWD 20 2 76 76 68 71 65 61 61 75
Length (l/s) 15 15 25 29 34 34 41 45
3 78 79 71 74 69 66 66 78
Height (l/s) 53 53 89 104 123 123 148 163
Nominal water connection size (Grooved coupling) (mm) 150 150 200 200 200 200 200 200
Dimensions (4)
Height (mm) 1690 1690 1810 1810 2000 2000 2000 2000
Length (mm) 3640 3640 3290 3670 3850 3850 3850 3850
Width (mm) 1850 1850 1970 1970 2040 2040 2040 2040
Shipping weight (kg) 4520 4520 6080 6480 8260 8470 8610 8880
Operating weight (kg) 4860 4860 6534 7012 9139 9384 9572 9929
System data
Refrigerant circuit 1 1 1 1 1 1 1 1
R134a refrigerant charge (kg) 217 217 217 233 311 311 311 319
Oil charge (l) 18.0 18.0 27.0 42.0 46.0 46.0 46.0 46.0
POE Oil type OIL00317

(1) Evaporator 12/7°C and 0.0 m²K/kW, and condenser at 30/35°C and 0.0 m²K/kW.
(2) According to AHRI Standard 550/590, based on TOPSS (Trane Official Product Selection Software).
(3) Net performances calculated as per EN 14511-2013.
(4) η s,c / SEER as defined in Directive 2009/125/EC of the European Parliament and of the Council with regard to Ecodesign requirements for Comfort
Chillers with 2000 kW maximum capacity - COMMISSION REGULATION (EU) N° 2016/2281 of 20 December 2016.
(5) At full load and in accordance with ISO9614.
(6) Inrush current in star/delta connection.

UNT-PRC002-GB
RLC-PRC045B-GB 11
19
General Data
Technical Data
Table 5 – General Data
Evaporator Condenser R134a
Compressor Evaporator Condenser
Water storage Water storage Refrigerant Oil Charge (l)
Code Code Code
(l) (l) Charge (kg)
150 HE B1 B1 B1 168 106 182 17
150 XE/HSE
FWD B1 C1 D1 08 225 12 125 20 217 30 17 45
Power
175 HE supply B2 B1 (V/Ph/Hz) B1 168 106 230/1/50 182 17
Capacities
175 XE/HSE B2 C1 D1 225 125 217 17
Cooling
225 SE capacity on water C1(1) D6 (kW) E5 5,2 193 8,3 132 15 217 18,8 2330,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
225 HE C1 D5 E4 220 148 217 23
Fan motor (type) 2 x direct drive centrifugal
225 SE/HSE
Fan power input (3) C1 D3 (kW) E3 0,23 281 0,46 181 0,65 217 1,04 231,51
250 SEamps (3)
Current C2 D6 (A) E5 1,1 193 2,2 135 3,1 217 4,7 235,5
250 HE amps
Start-up C2 D5 (A) E4 3,2 220 5,5 148 9,3 217 14,1 2316,5
275flow
Air XE C2 E1 F1 300 235 233 38
300 SE
minimum D1 D4 (m3/h) E4 490 220 980 148 1400 211 1800 232700
nominal
300 HE D1 D3 (m /h)
3
E3 820 281 1650 181 2300 211 3000 234500
maximum
325 SE D1 G1 (m /h)
3
G1 980 563 1970 321 2600 311 3600 425400
Main
350 HE coil D2 D1 E1 248 167 211 23
Water entering/leaving connections (type) ISO R7 rotating female
350 XE/HSE D2 F1 F2 394 224 278 38
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
350 SE D2
Electric heater (accessory for blower only) G2 G1 597 321 311 42
375 HE
Electric power supply D3 D1 (V/Ph/Hz) E1230/1/50 248 167
230/1/50 or 400/3/50 400/3/50 211 400/3/50 23
400/3/50
375 XE/HSE
Heating capacity D3 F1 (kW) F2 2/4 394 8 224 10 278 12 38 12
375water
Hot SE coil (accessory D3
for blower only) G2 G2 597 370 311 42
400 HE capacity (4)
Heating E3 D2 (kW) E2 6,3 265 12 178 17,4 211 22,4 2334,5
G2
425filter (filter box accessory)
XE/HSE E3 F2 F3 417 240 278 38
Quantity E3 G3 G3 2 656 2 400 2 319 2 42 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
Table
Quantity 6 – Minimum/Maximum Evaporator Flow Rates (l/s) - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Two pass Three pass Four pass Six pass
Condensate pump (accessory) (type) Centrifugal
Nominal
Water flow - lift height Nominal (l/h - mm) Nominal 24 - 500 Nominal
Evaporator Conn.
Not available for FWD30 Min andMax FWD45 Conn. Size Min Max Conn. Size Min Max Min Max Conn. Size
Code Size
Sound level (L/M/H speed) (mm) (mm) (mm)
(mm)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound B1 power level (5) 19 69 200 (dB(A))13 46
46/50/53 150 1048/51/54 34 100
56/60/63 - -
57/62/67 -
57/62/68
C1
Unit dimensions 25 88 200 17 59 150 13 44 100 - - -
Width x D1Depth 32 114 200 (mm) 21 76
890 x 600 200 161090 x 71057 150
1290 x 820 - - x 970
1290 - x 1090
1290
Height D2 35 124 200 (mm) 23 83 250 200 18 300 62 150350 - -450 - 650
Shipped D3unit dimensions
37 134 200 25 89 200 18 67 150 - - -
Width x D4Depth 27 97 200 (mm) 18 933 x 644 200
64 141133 x 75448 1333 x 864 -
150 1333- x 1008 1333*1133
-
Height D5 27 97 200 (mm) 18 64 260 200 14 310 48 150360 - -460 - 660
Weight (kg) 32 46 61 76 118
D6 23 81 200 15 54 200 12 40 150 - - -
Colour galvanised steel
E1 35 124 200 23 83 200 18 62 150 - - -
Recommended fuse size
F1 (aM/gI) 43
Unit alone 156 250 (A) 29 1048/16 200 22 8/16 78 1508/16 - -8/25 -8/25
Unit withF2 electric heater
46 (gI) 168 250 (A) 31 16 (2kW),25
112 200
(4kW) 23
40 (230V),3*16 84(400V) 1503*20 - -
3*25 -3*25
G1 - - - 39 140 250 29 105 200 20 70 150
(1) Conditions:
G2 Water entering/leaving
- - temperature:- 7/12 °C, Air inlet
42 temperature
152 27/19°C250 DB/WB - Nominal
32 air flow114 200 21 76 150
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
G3 - -
(3) At high speed with nominal air flow.
- 47 172 250 36 129 200 24 86 150
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Table 7 – Minimum/Maximum Condenser Flow Rates (l/s)
Heat exchanger operating limits:
Two pass
FWD:
*water temperature: max 100° C Nominal Conn. Size
Condenser Code Min. Max
*absolute service pressure: min 1 bar/max 11 bars (mm)
B1 15 53 150
Accessories - Hot water coil:
D1 15 53 150
*water temperature: min. +2° C/max. 100° C
E1 pressure: min 1 bar/max22
*absolute service 11 bars 80 200
E2 24 87 200
E3 25 89 200
E4 19 67 200
E5 16 57 200
F1 29 104 200
F2 27 97 200
F3 30 106 200
G1 34 123 200
G2 41 148 200
G3 45 163 200

4
20 UNT-PRC002-GB
RLC-PRC045B-GB
General Data

Table 8 – Evaporator Water Pressure Drop (kPa)


Water flow rates (l/s) for water only

Evap Passes Min Max 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160
B1 2 19 69 8 13 18 23 30 37 44 53 62 71
Sound
B1 power
3 13 46 levels
15 26 39 55 72 91 113
B1 4 10 34 17 37 62 92 129
C1 2 25 88 9 13 18 23 28 34 40 47 54 62 70 78 88
Discharge
C1 3 17 59 20 30 41 55 69 86 104 123
C1 4 13 44 28 48 71 99 131 168
Measurement
D1 2 conditions:
32 114 12 15 19 23 27 32 37 42 48 54 60 67 74 81 89 97
D1 3 21 76
Measurements taken in a room16adjacent
23 31 39 48 58 69 81 94 108 122
to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
D1 4 16 57 25 38 53 70 89 111 134 160
long)D2fixed
2
to its discharge
35 124
opening. 10 13 16 20 24 28 33 38 43 48 54 60 66 72 79 87 94 102
D2 3 23 83 14 20 26 34 42 51 60 71 82 94 106 119
D2 4 18 62 Fan 22 33 46 61 78 Power
96 117level
139 in dB(A), per Hz frequency band
164 Overall power
Unit D3 2 37 134 speed 125 10 250
13 16 19 50026
22 30 341000
38 42 47 2000
52 57 62 400073
68 79 858000
92 dB(A)
D3 3 25 89
1 55
12 17 22 29
50
36 43 51 60
42 69 79
37
89 100 112
37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
D3 4 19 67 18 28 39 51 65 81 98 116 136 158
3 58 57 50 42 32 40 43 53
D4 2 27 97 10 13 17 21 25 30 35 41 47 53 60 66 74 81
1 57 51 45 42 34 33 28 48
FWD D4
10 3 18 64 2 15 23 5832 42 53 66
54 80 95 11248 45 38 39 35 51
D4 4 14 48 3 21 36 55 6076 101 129 161
58 50 48 40 42 39 54
D5 2 27 97 1 5710 13 17 21
51 26 30 3545 41 47 53 42
60 67 74 82
34 33 28 48
FWD D5
12 3 18 64 2 15 23 5832 42 54 66
54 80 95 11248 45 38 39 35 51
D5 4 14 48 3 21 36 55 6077 102 130 58
161 50 48 40 42 39 54
D6 2 23 81 1 10 5613 18 23 62
28 34 40 4750 55 62 71 48
80 39 38 36 56
FWD D6
14 3 15 54 2 12 20 30 6142 55 70 66
87 105 55 53 47 46 45 60
D6 4 12 40 3 28 48 72 63
100 133 170 69 58 56 50 50 49 63
E1 2 35 124
1 57 10 13
63
16 20 24
51
28 32 37
49 40 39
42 47 53 58 64 71 77 84 91 99
37 57
FWD 20 2 61 66 55 53 47 46 45 60
E1 3 23 83 16 22 29 37 46 56 66 77 89 102 115 130
3 63 69 58 56 50 50 49 63
E1 4 18 62 24 36 50 66 84 104 126 149 175
F1 2 43 156 10 13 15 18 21 24 27 30 34 37 41 45 49 54 58 63 67 72 78 83 88 94 100
Intake
F1 3 29 104 15 20 26 32 39 46 54 62 71 80 90 101 112 123 136
F1 4 22 78 25 35 46 59 73 89 105 123 143 163 185
Measurement
F2 2 conditions:
46 168 11 13 16 18 21 24 27 30 33 37 40 44 48 52 56 60 65 69 74 79 84 89 95
F2 3 31 112
Measurements taken at the horizontal23air28intake.
34 41 48 55 63 72 81 90 100 110 121 132 144
F2 4 23 84 22 31 41 53 65 79 94 110 127 146 166 186
G1 3 39 140 14 18 22 26 30 35 40 46 51 57 63 70 76 83 91 98 106 114 123 131 140
Fan Power level in dB(A), per Hz frequency band Overall power
G1 4 29 105 19 25 33 41 49 58 68 79 90 102 115 128 142 156 171 187
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
G1 6 20 70 28 43 60 79 101 125 151 179 210 243 278
1 56 55 55 53 46 45 42 57
G2 3 42 152 15 19 23 26 31 35 40 45 50 55 61 67 73 79 86 93 100 107 115 122 130 139
FWD 08 2 63 62 60 60 53 53 53 64
G2 4 32 114 3 66 22 28 35
65 43 51 6063 69 79 89 62 100 112 124 136
56 150 163 178
55 57 67
G2 6 21 76 1 37 6252 69 88 109
58 132 156 18355212 242 275 58 51 48 44 61
FWD G3
10 3 47 172 2 66 63 15 18 2160 25 28 32 62 36 41 45 50 56 54 59 6555 70 76 81 52 87 93 100 106
66 113 120 127
G3 4 36 129 3 70 67 35 41 4863 56 64 73 65
23 29 59 122 133 145
82 91 101 111 59157 170 183 57 69
G3 6 24 86 1 30 62
42 56 71 8958 107 127 14955172 197 223 58251 280 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
Table 9 – Condenser 1 Pressure 66
Drop (kPa) 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
Water flow rates (l/s) for water only
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWDCond
20 Passes Min Max 102 15 20 25 7630 35 40 45
76 50 55 60 68 65 70 75 7180 85 90 65 95 100 105 110 115 120 125 130 135 140 145 150 155 160
61 61 75
B1 2 15 53 3 10 16 24 7834 44 56 79
70 85 71 74 69 66 66 78
D1 2 15 53 11 19 28 39 52 66 81 98
E1 2 22 80 12 17 22 28 34 41 49 57 66 76 86 97
E2 2 24 87 10 15 19 24 30 36 43 50 58 66 75 84 94
E3 2 25 89 10 13 18 22 28 33 40 46 53 61 69 78 87
E4 2 19 67 11 17 23 31 39 48 58 69 81 94
E5 2 16 57 15 22 31 40 51 63 77 91
F1 2 29 104 12 16 20 25 30 36 42 49 55 63 70 79 87 96 106
F2 2 27 97 14 18 23 29 35 41 48 56 64 72 81 90 100 111
F3 2 30 106 12 16 20 25 31 36 42 49 56 63 71 79 88 97 106 116
G1 2 34 123 13 17 21 25 30 35 40 46 52 58 65 72 79 87 95 103 112 121
G2 2 41 148 16 19 22 26 30 34 39 44 49 54 59 65 71 77 84 90 97 105 112 120 128
G3 2 45 163 13 16 19 23 26 30 34 38 42 47 51 56 62 67 73 78 85 91 97 104 111 118 125 133

UNT-PRC002-GB
RLC-PRC045B-GB 11
21
Electrical Data
Technical Data
Table 10 – Compressor motor electrical data 50 Hz
Nominal voltage (operating range)

380 V ( 361V - 399V) 400 V (380V - 420V) 415 V (394V - 436V)

FWD Max Max 08 Max 12 Max 20 30 up 45


Max Start up Start up Max Start
Unit supplyPower
Powertype Amps amp
Power
(V/Ph/Hz) Power
Amps amp
Power Power 230/1/50
Amps amp
Power
Capacities input Factor input Factor input Factor
(A) (A) (A) (A) (A) (A)
(kW)
Cooling capacity on water (1) (kW) (kW) 5,2 8,3 (kW) 15 18,8 30,1
225 SE 201 349 456 0.88 209 349 480 0.87 213 349 498 0.85
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
250 SE 201 349 456 0.88 209 349 480 0.87 213 349 498 0.85
Fan motor (type) 2 x direct drive centrifugal
300 SE 271 455 711 0.91 280 455 748 0.89 284 455 776 0.87
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
325 SE 271 455 711 0.91 280 455 748 0.89 284 455 776 0.87
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
350 SEamps 271
Start-up 455 711 0.91
(A) 280 3,2 455 748 0.89
5,5 284 9,3 455 776
14,1 0.87
16,5
375
Air SE
flow 288 488 711 0.90 301 488 748 0.89 306 488 776 0.87
minimum (m3/h) 490 980 1400 1800 2700
150 HE
nominal 139 233 391 0.91
(m 3
/h) 145 820 233 412 0.90
1650 148 2300 233 428
3000 0.88
4500
175 HE
maximum 139 233 391 0.91
(m 3
/h) 145 980 233 412 0.90
1970 148 2600 233 428
3600 0.88
5400
225 coil
Main HE 201 349 456 0.88 209 349 480 0.87 213 349 498 0.85
250 HE
Water 201
entering/leaving 349
connections 456 0.88
(type) 209 349 480 0.87 ISO 213
R7 rotating 349
female 498 0.85
300 HE 271 455 711 0.91
(Dia) 280 3/4" 455 748 0.89
3/4" 284 1 1/2" 455 1 776
1/2" 0.87
1 1/2"
350 HEheater 271
Electric 455blower
(accessory for 711
only) 0.91 280 455 748 0.89 284 455 776 0.87
375 HEpower 271
Electric supply 455 711 0.91
(V/Ph/Hz) 280 230/1/50
455 748 0.89
230/1/50 or 400/3/50 284400/3/50 455 776
400/3/50 0.87
400/3/50
400 HEcapacity
Heating 288 488 711 0.90
(kW) 301 2/4 488 748 80.89 306 10 488 776
12 0.8712
Hot water coil (accessory for blower only)
150 XEcapacity
Heating 139(4) 233 391 0.91
(kW) 145 6,3 233 412 120.90 148 17,4 233 428
22,4 0.88
34,5
G2175 XE(filter box
filter 139 accessory)
233 391 0.91 145 233 412 0.90 148 233 428 0.88
225 XE
Quantity 201 349 456 0.88 209 2 349 480 20.87 213 2 349 498
2 0.852
275 XE
Dimensions 201
( LxWxth) 349 456 0.88
(mm) 209386x221x8349 480 486x271x8
0.87 213586x321x8 349 498
586*421*8 0.85
586*621*8
G4325 XE(filter box
filter 271 accessory)
455 711 0.91 280 455 748 0.89 284 455 776 0.87
350 XE
Quantity 271 455 711 0.91 280 - 455 748 20.89 284 2 455 776
2 0.872
375 XE
Dimensions 271
( LxWxth) 455 711 0.91
(mm) 280 - 455 748 486x264x48
0.89 284
586x314x48 455 776
586*414*48 0.87
586*614*48
425 XE
Condensate 288 (accessory)
pump 488 711 0.90
(type) 301 488 748 0.89 306
Centrifugal488 776 0.87
Water flow - lift height (l/h - mm) 24 - 500
150available
Not HSE 142
for FWD30 and221FWD45
< I Max. 0.98 148 218 < I Max. 0.98 150 213 < I Max. 0.98
175 HSE
Sound 142 speed)221
level (L/M/H < I Max. 0.98 148 218 < I Max. 0.98 150 213 < I Max. 0.98
225 HSE
Sound pressure 205
level (5) 318 < I Max. 0.98
(dB(A)) 213 36/40/43314 < I Max. 38/41/44
0.98 21746/50/53 309 < I Max.
47/52/57 0.98
47/52/58
275 HSE
Sound 205 (5)
power level 318 < I Max. 0.98
(dB(A)) 213 46/50/53314 < I Max. 48/51/54
0.98 21756/60/63 309 < I Max.
57/62/67 0.98
57/62/68
325 dimensions
Unit HSE 276 429 < I Max. 0.98 286 421 < I Max. 0.98 290 412 < I Max. 0.98
350 HSE
Width x Depth 276 429 < I Max. 0.98
(mm) 286890 x 600421 < I Max.1090 0.98
x 710 2901290 x 820412 <Ix
1290 Max.
970 0.98x 1090
1290
375 HSE
Height 276 429 < I Max. 0.98
(mm) 286 250 421 < I Max. 300 0.98 290 350 412 < 450
I Max. 0.98
650
425 HSEunit dimensions
Shipped 295 457 < I Max. 0.98 307 452 < I Max. 0.98 311 442 < I Max. 0.98
Width
Data arex subject
Depth to change without notice. Please (mm) 933 x 644
refer to unit nameplate data. 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

4
22 UNT-PRC002-GB
RLC-PRC045B-GB
Electrical Data

Table 11 – Electrical connections


Option
Option non-fused Option Option
terminal
disconnect switch fused disconnect switch circuit breaker
block
Power
Dis- Dis- Circuit
Power cable cross Fuse Power cable cross Power cable cross cable
connect connect breaker
Sound power levels
switch
section
switch
size section
size
section cross sec-
tion
Min Max Min Max Min Max Max
Unit type (A) (A) (A) (A)
Discharge (mm²) (mm²) (mm²) (mm²) (mm²) (mm²) (mm²)
225 SE 400 185 240 500 400T2 240 240 630 2x70 2x240 2x300
250 SE 400 185 240 500 400T2 240 240 630 2x70 2x240 2x300
Measurement
300 SE
conditions:
630 2x150 2x300 630 500T3 2x150 2x300 630 2x70 2x240 2x300
Measurements
325 SE taken
630 in a2x150
room adjacent
2x300 to the room
630 containing
500T3 the FWD,2x300
2x150 at the outlet
630of the rectangular
2x70 duct
2x240 (1.5 m
2x300
long) 350
fixed
SE to its630
discharge opening.
2x150 2x300 630 500T3 2x150 2x300 630 2x70 2x240 2x300
375 SE 630 2x150 2x300 630 500T3 2x150 2x300 630 2x70 2x240 2x300
Fan Power level in dB(A), per Hz frequency band Overall power
150 HE 315 150 240 315 250T2 150 240 400 2x70 2x240 2x300
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
175 HE 315 150 240 315 250T2 150 240 400 2x70 2x240 2x300
1 55 50 42 37 37 31 30 46
225 HE 400 185 240 500 400T2 240 240 630 2x70 2x240 2x300
FWD 08 2 57 54 47 40 30 38 40 50
250 HE 400 185 240 500 400T2 240 240 630 2x70 2x240 2x300
3 58 57 50 42 32 40 43 53
300 HE 630 1 2x150 57 2x300 51630 500T3
45 2x150
42 2x30034 630 33 2x70 28 2x240 2x300
48
FWD 10350 HE 630 2 2x150 58 2x300 54630 500T3
48 2x150
45 2x30038 630 39 2x70 35 2x240 2x300
51
375 HE 630 3 2x150 60 2x300 58630 500T3
50 2x150
48 2x30040 630 42 2x70 39 2x240 2x300
54
400 HE 630 1 2x150 57 2x300 51630 500T3
45 2x150
42 2x30034 630 33 2x70 28 2x240 2x300
48
FWD 12 2 58 54 48 45 38 39 35 51
150 XE 315 3 150 60 240 58315 250T2
50 15048 240 40 400 42 2x70 39 2x240 2x300
54
175 XE 315 1 150 56 240 62315 250T2
50 15048 240 39 400 38 2x70 36 2x240 2x300
56
FWD 14225 XE 400 2 185 61 240 66500 400T2
55 24053 240 47 630 46 2x70 45 2x240 2x300
60
275 XE 400 3 185 63 240 69500 400T2
58 24056 240 50 630 50 2x70 49 2x240 2x300
63
325 XE 630 1 2x150 57 2x300 63630 500T3
51 2x150
49 2x30040 630 39 2x70 37 2x240 2x300
57
FWD 20350 XE 630 2 2x150 61 2x300 66630 500T3
55 2x150
53 2x30047 630 46 2x70 45 2x240 2x300
60
375 XE 630 3 2x150 63 2x300 69630 500T3
58 2x150
56 2x30050 630 50 2x70 49 2x240 2x300
63
425 XE 630 2x150 2x300 630 500T3 2x150 2x300 630 2x70 2x240 2x300

Intake
150 HSE 315 150 240 315 250T2 150 240 400 2x70 2x240 2x300
175 HSE 315 150 240 315 250T2 150 240 400 2x70 2x240 2x300
225 HSE
Measurement 400
conditions: 185 240 500 400T2 240 240 630 2x70 2x240 2x300
275 HSE 400 185 240 500 400T2 240 240 630 2x70 2x240 2x300
Measurements
325 HSE
taken
630
at the horizontal
2x150
air
2x300
intake.
630 500T3 2x150 2x300 630 2x70 2x240 2x300
350 HSE 630 2x150 2x300 630 500T3 2x150 2x300 630 2x70 2x240 2x300
375 HSE 630 Fan 2x150 2x300 630 level in500T3
Power dB(A), per 2x150
Hz frequency2x300
band 630 2x70 2x240Overall2x300
power
Unit 425 HSE 630 speed 2x150 1252x300 630
250 500T3
500 2x150
1000 2x300
2000 630 4000 2x70 80002x240 2x300
dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

UNT-PRC002-GB
RLC-PRC045B-GB 11
23
Dimensions
Technical Data
Table 12 – Dimensions
Unit Dimensions (mm)

Unit type Width Length Height


RTHD 225 SE 1600 3290 1940
FWD RTHD 250 SE 1600 3290 08 1940 12 20 30 45
RTHD
Power 300 SE
supply 1600 (V/Ph/Hz)3290 1940 230/1/50
RTHD 325 SE
Capacities 1600 3290 1940
RTHD
Cooling 350 SEon water (1) 1600
capacity (kW) 3290 5,2 1940 8,3 15 18,8 30,1
RTHD
Heating 375 SEon water (2) 1600
capacity (kW) 3290 6,3 1940 11,9 18,9 20,9 38,2
Fan motor (type) 2 x direct drive centrifugal
FanRTHD
power150 input HE(3) 1600 (kW) 3170 0,23 1850 0,46 0,65 1,04 1,51
RTHD
Current 175(3)
amps HE 1600 (A) 3170 1,1 1850 2,2 3,1 4,7 5,5
RTHDamps
Start-up 225 HE 1600 (A) 3290 3,2 1940 5,5 9,3 14,1 16,5
RTHD 250 HE
Air flow 1600 3290 1940
RTHD 300 HE
minimum 1600 (m3/h) 3290 490 1940 980 1400 1800 2700
RTHD 350 HE
nominal 1600 (m3/h) 3690 820 1940 1650 2300 3000 4500
RTHD 375 HE
maximum 1600 (m3/h) 3690 980 1940 1970 2600 3600 5400
MainRTHDcoil 400 HE 1600 3690 1940
Water entering/leaving connections (type) ISO R7 rotating female
RTHD 150 XE 1600 (Dia) 3640 3/4" 1850 3/4" 1 1/2" 1 1/2" 1 1/2"
RTHD
Electric 175 (accessory
heater XE 1600 only)
for blower 3640 1850
RTHD
Electric 225 supply
power XE 1600 (V/Ph/Hz)3290 230/1/50 1940 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
RTHD
Heating 275 XE
capacity 1600 (kW) 3670 2/4 1940 8 10 12 12
Hot RTHD
water 325 XE
coil (accessory 1800 only)
for blower 3850 2035
Heating
RTHD capacity
350 XE(4) 1800 (kW) 3850 6,3 2040 12 17,4 22,4 34,5
G2 filter
RTHD(filter
375 boxXE accessory) 1800 3850 2040
Quantity
RTHD 425 XE 1800 3850 2 2040 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 RTHD
filter (filter
150 HSE box accessory) 1690 3640 1850
Quantity
RTHD 175 HSE 1690 3640 - 1850 2 2 2 2
Dimensions
RTHD 225 ( LxWxth)
HSE 1810 (mm) 3290 - 1970 486x264x48 586x314x48 586*414*48 586*614*48
Condensate
RTHD 275 pump
HSE (accessory) 1810 (type) 3670 1970 Centrifugal
Water
RTHD flow - liftHSE
325 height 2000 (l/h - mm)3850 2040 24 - 500
NotRTHD
available
350 forHSEFWD30 and FWD452000 3850 2040
Sound
RTHD level
375 (L/M/H
HSE speed) 2000 3850 2040
Sound pressure
RTHD 425 HSE level (5) 2000 (dB(A))3850 36/40/43 2040 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

4
24 UNT-PRC002-GB
RLC-PRC045B-GB
Dimensions and Weights
RTHD 150 HE
RTHD 175 HE
Note: Connection configuration is available left or right hand.

Sound power levels


Discharge

Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39
1= Evaporator
38 36 56
FWD 14 2 61 66 55 53 47 2= Condenser
46 45 60
3 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Left hand Right hand
Intake

Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 Evaporator 2 passes
2 (option)
66 63 Evaporator 60 3 passes62 (standard) 56 Evaporator
55 452passes (option)
66
Right hand
3 70 67 63Right hand 65 59 59 Right
57 hand 69
1 62 58 55 58 51 48 44 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 168 213 726 352 163 123 203 203 334 588

21 bar 183 418 711 367 183 148 283 358 348 575

UNT-PRC002-GB
RLC-PRC045B-GB 11
25
Dimensions and Weights
Technical Data
RTHD 150 XE
RTHD 175 XE
Note: Connection configuration is available left or right hand.

FWD 08 12 20 30 45
Power supply (V/Ph/Hz) 230/1/50
Capacities
Cooling capacity on water (1) (kW) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
Fan motor (type) 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m3/h) 490 980 1400 1800 2700
nominal (m3/h) 820 1650 2300 3000 4500
maximum (m3/h) 980 1970 2600 3600 5400
Main coil
Water entering/leaving connections (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 8 10 12 12
Hot water coil (accessory for blower only)
Heating capacity (4) (kW) 6,3 12 1 = Evaporator
17,4 22,4 34,5
G2 filter (filter box accessory) 2 = Condenser
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
LeftCondensate
hand pump (accessory) (type) Right hand Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended
Evaporatorfuse size
2 passes (option) Evaporator 3 passes (standard) Evaporator 4 passes (option)
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Right hand
Unit with electric heater (gI) (A)
Right hand 40 (230V),3*16 (400V)
16 (2kW),25 (4kW) 3*20
Right 3*25
hand 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil: Condenser 2 passes (standard)


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 168 213 726 352 163 123 203 203 334 588

21 bar 183 418 711 367 183 148 283 358 348 575

4
26 UNT-PRC002-GB
RLC-PRC045B-GB
Dimensions and Weights

RTHD 225 SE / RTHD 225 HE / RTHD 225 XE


RTHD 250 SE / RTHD 250 HE / RTHD 300 SE
RTHD 300 HE / RTHD 325 SE / RTHD 350 SE
RTHD 375 SE
Sound power levels Note: Connection configuration is available left or right hand.

Discharge

Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 1 =50
Evaporator49 63
1 57 63 51 49 40
2 =39
Condenser37 57
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Left hand Right hand
Intake

Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
Evaporator 3 passes
65 (standard)
Evaporator574 passes (option)
Evaporator 2 passes
3 (option)
70 67 63 59 59 69
55 Right hand Right hand 61
Right 1hand 62 58 58 51 48 44
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 201 230 766 378 181 150 199 199 359 657

21 bar 183 418 750 395 183 178 323 398 373 643

UNT-PRC002-GB
RLC-PRC045B-GB 11
27
Dimensions and Weights
Technical Data
RTHD 275 XE
Note: Connection configuration is available left or right hand.

FWD 08 12 20 30 45
Power supply (V/Ph/Hz) 230/1/50
Capacities
Cooling capacity on water (1) (kW) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
Fan motor (type) 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m3/h) 490 980 1400 1800 2700
nominal (m3/h) 820 1650 2300 3000 4500
maximum (m3/h) 980 1970 2600 3600 5400
Main coil
Water entering/leaving connections (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 8 10 12 12
Hot water coil (accessory for blower only)
Heating capacity (4) (kW) 6,3 12 17,4 22,4 34,5
G2 filter (filter box accessory)
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 1586x321x8
= Evaporator586*421*8 586*621*8
G4 filter (filter box accessory) 2 = Condenser
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Left hand
Sound level (L/M/H speed)
Right hand
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Evaporator
Unit with electric 2 heater
passes (gI)(option) (A) Evaporator 3 passes 40
16 (2kW),25 (4kW) (standard)
(230V),3*16 (400V)Evaporator
3*20 4 passes (option)
3*25 3*25
Right hand Right hand Right hand
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C Condenser 2 passes (standard)
*absolute service pressure: min 1 bar/max 11 bars Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 201 230 766 378 181 150 199 199 359 657

21 bar 183 418 750 395 183 178 323 398 373 643

4
28 UNT-PRC002-GB
RLC-PRC045B-GB
Dimensions and Weights

RTHD 350 HE
RTHD 375 HE
RTHD 400 HE
Note: Connection configuration is available left or right hand.
Sound power levels
Discharge

Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 1 = Evaporator
39 54
1 56 62 50 48 39 38 2 = Condenser
36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63

Left hand
Intake Right hand

Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 56 55 Evaporator
52 4 passes 66
(option)
Evaporator 23 passes (option)
70 67 Evaporator
63 3 passes65 (standard)59 59 57 69
Right
1 hand 62 58 55 Right hand 58 51 48 Right
44 hand 61
FWD 12 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 218 238 720 288 189 150 199 199 359 657

21 bar 228 458 708 299 228 178 323 398 373 643

UNT-PRC002-GB
RLC-PRC045B-GB 11
29
Dimensions and Weights
Technical Data
RTHD 325 XE
RTHD 350 XE
RTHD 375 XE
RTHD 425 XE
FWD 08 12 20 30 45
Power supply Note: Connection
(V/Ph/Hz) configuration is available left or right hand.
230/1/50
Capacities
Cooling capacity on water (1) (kW) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
Fan motor (type) 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m3/h) 490 980 1400 1800 2700
nominal (m3/h) 820 1650 2300 3000 4500
maximum (m3/h) 980 1970 2600 3600 5400
Main coil
Water entering/leaving connections (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity (kW) 2/4 8 10 12 12
Hot water coil (accessory for blower only)
Heating capacity (4) (kW) 6,3 12 17,4 22,4 34,5
G2 filter (filter box accessory)
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
Quantity - 1 = Evaporator
2 2 2 2
Dimensions ( LxWxth) (mm) - 2 =486x264x48
Condenser 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
LeftWidth
handx Depth (mm) Right
890 x 600 hand 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25

(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
Evaporator
(4) Water 2 passes
entering/leaving (option)
temperature Evaporator
90/70 °C, air inlet temperature 3 Nominal
20 °C DB, passes air(standard)
flow. Evaporator 4 passes (option)
Right hand
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement
Right hand
is taken in the room containing the blower unit. Right hand

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J
TYPE
10 bar 238 276 860 289 235 184 232 378 734

4
30 21 bar 248 458 854 295 248 188 323 375 736 UNT-PRC002-GB
RLC-PRC045B-GB
Dimensions and Weights

RTHD 150 HSE


RTHD 175 HSE
Note: Connection configuration is available left or right hand.
915
Sound power levels 873
(7) (3) (6) 268
Discharge
(24)
(5)
Measurement conditions:
Measurements taken in a room adjacent to the(4)room containingB
the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening. F E
1835 1850
Fan Power level in dB(A), per Hz frequency band Overall power
(1) speed (2)
Unit 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
3 58 57 50 42 32 40 43 53
1 (15)
57 51 45 42 34 33 28 48
FWD 10 2 97 58 50 54 48 45(20) (21)
38 39 35 51
3 152760B 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2
1690
58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56
(13) 62 50 48 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 503010 A 50 49 63
1 57 63 51201 49 40 39 37 57
225 (21)
FWD 20 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63

(23)
Intake
F E
Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 468 46 45 664 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 57 67
1 62 58 55 58 513203 A 48 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
Evaporator 2 passes
1 (option) 62 Evaporator55
58 3 passes (standard)
58 51 Evaporator
48 444passes (option)
61
FWD 12 Right hand2 66 63 Right
60 hand 62 56 55 Right
52 hand 66
3 70 67 63 65 59 59 57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 168 213 726 352 163 123 203 203 334 588

21 bar 183 418 711 367 183 148 283 358 348 575

UNT-PRC002-GB
RLC-PRC045B-GB 11
31
Dimensions and Weights
Technical Data
RTHD 225 HSE
Note: Connection configuration is available left or right hand.
1092
(6) 1051
FWD 08 12 20 30 45
271
Power supply (V/Ph/Hz) 230/1/50
Capacities 318 (24)
Cooling capacity on water (1) (kW)(5) 5,2 8,3 15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 11,9 18,9 20,9 38,2
Fan motor (type)
(4) 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1
E 4,7 5,5
1970 1938 F
Start-up amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m3/h) 490 980 1400 1800 2700
(2)
nominal (1) (m3/h) 820 1650 2300 3000 4500
maximum (m3/h) 980 1970 2600 3600 5400
Main coil
Water entering/leaving connections (type) ISO R7 rotating female
50 (15) 76 (Dia) 3/4" 3/4" (20) (21) 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
1575 B
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity 1810 (kW) 2/4 8 10 12 12
Hot water coil (accessory for blower only)
Heating capacity (4) (13)(kW) 225 6,3 12 17,4 22,4 34,5
G2 filter (filter box accessory) 2490 A
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (mm) 386x221x8 486x271x8(21) 189
586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory)
(23)
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed) F
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 E
47/52/57 47/52/58
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions 468
664
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360 460 660
Weight (kg) 32 46 61 76 118
Colour 2741 A
galvanised steel
Recommended fuse size
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric
Evaporator heater (gI)
2 passes (option) (A) Evaporator 3 passes
16 (2kW),25 40 (230V),3*16 (400V) Evaporator
(4kW) (standard) 3*20 4 passes
3*25(option) 3*25
Right hand Right hand
Right
(1) Conditions: hand
Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Condenser 2 passes (standard)
Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 201 230 766 378 181 150 199 199 359 657

21 bar 183 418 750 395 183 178 323 398 373 643

4
32 UNT-PRC002-GB
RLC-PRC045B-GB
Dimensions and Weights

RTHD 275 HSE


Note: Connection configuration is available left or right hand.
1092
1051
Sound power levels
(7) (3) (6) 267
141 (24)
Discharge (5)

(4)
Measurement conditions:
Measurements
1970 taken in a room adjacent
(2)to1938
the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening. F E

Fan Power level in dB(A), per Hz frequency band Overall power


(1)
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57 54 47 40 30 38 40 50
(20) (21)
3 50 (15) 58 76 57 50 42 32 40 43 53
1 57 51 45 42 34 33 28 48
FWD 10 21575 B 58 54 48 45 38 39 35 51
3 1810 60 58 50 48 40 42 39 54
1 57 51 45 42 34 33 28 48
FWD 12 2 58 54
225 48 45 38 39 35 51
(13)
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 3206 A 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 3010 A 50 49 74 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 53 47 (21) 46 45 60
3 63 69 58 56 50 50 49 63
(23)
Intake

Measurement conditions: F E
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 56 55 664 57 67
1 62 58 55 58 51 48 44 61
FWD 10 2 66 63 60 62 468 56 55 52 66
3 70 67 63 65 59 59 57 69
1 62 58 55 58 51 48 44 61
FWDEvaporator
12 2 passes
2 (option) 66 63 Evaporator 60 3 passes62(standard)56 Evaporator
55 4 passes
52 (option)
66
Right hand3 70 67 63 Right hand 65 59 59 Right hand
57 69
1 66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J K
TYPE
10 bar 201 230 766 378 181 150 199 199 359 657

21 bar 183 418 750 395 183 178 323 398 373 643

UNT-PRC002-GB
RLC-PRC045B-GB 11
33
Dimensions and Weights
Technical Data
RTHD 325 HSE
RTHD 350 HSE
RTHD 375 HSE
Note: Connection configuration is available left or right hand.
FWD 08 12 20 30 45
Power supply (V/Ph/Hz) 230/1/501057
Capacities
Cooling capacity on water (1) 1015
(7) (3)(kW) 5,2 8,3
(6)11,9
15 18,8 30,1
Heating capacity on water (2) (kW) 6,3 (24) 18,9 270 20,9 38,2
Fan motor (type)(5) 127 2 x direct drive centrifugal
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
Current amps (3) (A) 1,1 2,2 3,1 4,7 5,5
Start-up amps (A) (4) 3,2 5,5 9,3 14,1 16,5
Air flow
minimum (m3/h) 490 980 1400 1800
E 2700
nominal 2040 (m3/h) 820 F 1650 2300 3000 4500
2034
maximum (m3/h)(2) 980 1970 2600 3600 5400
Main coil
(1) connections
Water entering/leaving (type) ISO R7 rotating female
(Dia) 3/4" 3/4" 1 1/2" 1 1/2" 1 1/2"
Electric heater (accessory for blower only)
Electric power supply (V/Ph/Hz) 230/1/50 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
Heating capacity 50 (15) (kW)55 2/4 8 10 12 12
Hot water coil (accessory for blower only) (20) (21)
1797 B
Heating capacity (4) (kW) 6,3 12 17,4 22,4 34,5
G2 filter (filter box accessory) 2000
Quantity 2 2 2 2 2
Dimensions ( LxWxth) (13) (mm) 386x221x8 486x271x8 586x321x8 586*421*8 586*621*8
G4 filter (filter box accessory) 3310 A
Quantity - 2 2 2 2
Dimensions ( LxWxth) (mm) 225 - 88 486x264x48(21) 586x314x48 586*414*48 586*614*48
Condensate pump (accessory) (type) Centrifugal (23)
Water flow - lift height (l/h - mm) 24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
F E
Sound power level (5) (dB(A)) 46/50/53 48/51/54 56/60/63 57/62/67 57/62/68
Unit dimensions
Width x Depth (mm) 890 x 600 1090 x 710 1290 x 820 1290 x 970 1290 x 1090
Height (mm) 250 300 350 450 650
Shipped unit dimensions
Width x Depth (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 310 360
664 460 660
Weight (kg) 32 46 61 76 118
Colour 468 galvanised steel
Recommended fuse size 3206 A
Unit alone (aM/gI) (A) 8/16 8/16 8/16 8/25 8/25
Unit with electric heater (gI) (A) 16 (2kW),25 (4kW) 40 (230V),3*16 (400V) 3*20 3*25 3*25
Evaporator 2 passes (option) Evaporator 3 passes (standard) Evaporator 4 passes (option)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
Right
(2) Conditions: Water hand temperature: 50/45 °C, Air inlet temperature
entering/leaving Right20°Chand
DB - Nominal air flow Right hand
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.

Heat exchanger operating limits:


FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars

Accessories - Hot water coil:


*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Condenser 2 passes (standard)
Right hand

WATER
BOX A B C D E F G H J
TYPE
10 bar 238 276 860 289 235 184 232 378 734

21 bar 248 458 854 295 248 188 323 375 736

4
34 UNT-PRC002-GB
RLC-PRC045B-GB
Dimensions and Weights

RTHD 425 HSE


Note: Connection configuration is available left or right hand.
987
946
Sound power levels (3) (6) (24) 271
127
Discharge (5)

Measurement conditions: (4)


Measurements taken in a room adjacent to the room containing Fthe FWD, at the outlet of the rectangularEduct (1.5 m
2040 2034
long) fixed to its discharge opening. (2)

Fan Power level in dB(A), per Hz frequency band Overall power


(1)
Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 55 50 42 37 37 31 30 46
FWD 08 2 57
(15) 54 47 40 30 38 40 50
3 50 58 5755 50 42 (20) 32(21) 40 43 53
1 57
1797 B 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
3 2000
60 58 50 48 40 42 39 54
1 57 (13) 51 45 42 34 33 28 48
FWD 12 2 58 54 48 45 38 39 35 51
3 60 58 50 48 40 42 39 54
1 56 62 50 48 39 38 36 56
225
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 56 50 3310 A 50 49 63
1 57 63 51 49 40 39 37 57
(21)
FWD 20 2 61 66 55 53 88 47 46 (23) 45 60
3 63 69 58 56 50 50 49 63

Intake
F E
Measurement conditions:
Measurements taken at the horizontal air intake.

Fan Power level in dB(A), per Hz frequency band Overall power


Unit speed 125 250 500 1000 2000 4000 8000 dB(A)
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
3 66 65 63 62 458
56 55 57 67
1 62 58 55 58 51 48 664 44 61
FWD 10 2 66 63 60 62 56 55 52 66
3 70 67 63 65 59 3206 A 59 57 69
1 62 58 55 58 51 48 44 61
FWD 12 63Evaporator 603 passes (standard) Evaporator 452passes (option)
Evaporator 2 2passes 66
(option) 62 56 55 66
3
Right1 hand
70 67 Right hand 65
63 59 59 Right
57 hand 69
66 65 65 65 57 50 46 68
FWD 14 2 73 72 69 71 64 59 57 74
3 78 76 73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
FWD 20 2 76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78

Condenser 2 passes (standard)


Right hand

WATER
BOX A B C D E F G H J
TYPE
10 bar 238 276 860 289 235 184 232 378 734

21 bar 248 458 854 295 248 188 323 375 736

UNT-PRC002-GB
RLC-PRC045B-GB 11
35
Mechanical Specifications
Technical Data
General Adaptive Controls
Exposed steel surfaces shall be painted with an air-dry There are many objectives that the controller must meet,
white paint RAL 9002 prior to shipment. Each unit shall but it cannot satisfy more than one objective at a time.
ship with a full operating charge of refrigerant and oil. Typically, the controllers primary objective is to maintain
Molded
FWD neoprene isolation pads shall be supplied for 08 the evaporator12leaving water 20
temperature.30 45
Power supply (V/Ph/Hz) 230/1/50
placement
Capacities
under all support points. Startup and operator Whenever the controller senses that it can no longer
instructions by factory-trained
Cooling capacity on water (1) service personnel
(kW) are 5,2 meet its primary 8,3 objective without
15 triggering
18,8 a protective
30,1
included.
Heating capacity on water (2) (kW) 6,3 shutdown, it focuses
11,9 on the most
18,9 critical secondary
20,9 38,2
Fan motor (type)
objective. When the2secondary
x direct drive centrifugal
objective is no longer
Compressor
Fan power input (3) and Motor (kW) 0,23 0,46
critical, the controller
0,65
reverts 3,1
1,04
to its primary4,7
1,51
objective 5,5
Current amps (3) (A) 1,1 2,2
The unitamps
Start-up shall have a semi-hermetic direct-
(A) drive,
30003,2 5,5 9,3 14,1 16,5
rpm, rotary compressor with capacity control slide valve,
Air flow Rapid Restart
minimum
oil sump heater and differential pressure (m /h) 490
refrigerant oil
3
The controller980 1400 chiller to
allows the Sintesis 1800
perform 2700
nominal (m /h) 3
820 1650 2300 3000 4500
flow
maximum
system. Four pressure lubricated rolling
(m /h)
element980
3 a Rapid Restart.1970
A Rapid Restart2600
is performed
3600
after a 5400
bearing
Main coil groups shall support the rotating assembly. momentary power loss if it occurs during operation.
Motor shall be a suction
Water entering/leaving gas cooled, hermetically
connections (type) sealed, Similarly, if the chillerISOshuts downfemale
R7 rotating on a non-latching
two pole, squirrel cage induction type. (Dia) 3/4"
diagnostic and 3/4"
the diagnostic 1 1/2"
later clears 1itself,
1/2" 1 1/2"
a Rapid
Electric heater (accessory for blower only)
HSE version
Electric power supplywill fit an Adaptive Frequency (V/Ph/Hz) Drive (AFD) Restart 230/1/50
230/1/50 will beorinitiated
400/3/50 400/3/50 400/3/50 400/3/50
Heating
to capacity
regulate the compressor motor speed (kW)at partial load. 2/4 8 10 12 12
Hot water coil (accessory for blower only) AdaptiSpeed Control
Heating capacity (4)
Evaporator-Condenser (kW) 6,3 The speed control 12 17,4
is now optimized 22,4
mathematically 34,5
and
G2 filter (filter box accessory)
All tube sheets shall be carbon steel plate. Evaporator 2
Quantity controlled simultaneously.
2 The2 increased performance
2 2of
and condenser
Dimensions ( LxWxth)tubes should be individually (mm) replaceable. 386x221x8 the UC800 486x271x8
Controller allows the chiller to
586x321x8 operate longer
586*421*8 586*621*8
G4 filter (filter box accessory)
Standard tubes shall be externally finned, internally - at higher efficiency, and with greater stability.
Quantity 2 2 2 2
enhanced seamless
Dimensions ( LxWxth) copper with lands at
(mm) all tube sheets. - Variable-Primary486x264x48 Flow (VPF)586x314x48 586*414*48 586*614*48
Evaporator
Condensate pump tubes shall be 25.4 mm diameter.
(accessory) (type) Condenser Centrifugal
Water flow - lift Chilled-water systems that 24 vary the water flow through
tubes shall beheight
19.05 mm diameter. Tubes (l/h - mm)shall be - 500
Not available for FWD30 and FWD45 chiller evaporators have caught the attention of
mechanically expanded
Sound level (L/M/H speed) into tube sheets. Condenser and
engineers, contractors, building owners, and operators.
evaporator
Sound pressure tubes shall be mechanically
level (5) fastened to tube
(dB(A)) 36/40/43 38/41/44 46/50/53 47/52/57 47/52/58
Varying the 48/51/54
water flow reduces the energy consumed by
supports. The water boxes shall be cast iron or fabricated
Sound power level (5) (dB(A)) 46/50/53 56/60/63 57/62/67 57/62/68
Unit dimensions pumps, while having limited effect on the chiller energy
steel available with Victaulic connections. 890 x 600 consumption. 1090This
x 710strategy
Width x Depth (mm) can
1290 be a significant
x 820 1290 x 970source
1290 xof1090
Height (mm) 250 300 350 450 650
Refrigerant Circuit energy savings, depending on the application.
Shipped unit dimensions
An
Widthelectronically
x Depth controlled expansion (mm) valve shall be 933 x 644
TD7 Operator 1133 x 754
Interface 1333 x 864 1333 x 1008 1333*1133
Height
provided to maintain proper refrigerant(mm) flow. 260 310 360 460 660
Weight (kg) 32 The standard TD7 46 display provided61 with the76Trane UC800118
Colour UC800 Controller
Tracer controller features a 7” LCD galvanised steel
touch-screen, allowing
Recommended fuse size
Today’s
Unit aloneSintesis
(aM/gI) chillers offer predictive (A) controls that 8/16 access to all operational
8/16 inputs
8/16and outputs. 8/25This is an8/25
anticipate and heater
Unit with electric compensate
(gI) for load changes. (A) Other advanced
16 (2kW),25 (4kW) interface(400V)
40 (230V),3*16 that allows
3*20the user to3*25access any3*25
control strategies
(1) Conditions: made possible
Water entering/leaving with
temperature: 7/12 the
°C, AirTracer UC800 27/19°Cimportant
inlet temperature
information concerning setpoints, active
DB/WB - Nominal air flow
controls are:
(2) Conditions: temperatures,
Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow modes, electrical data, pressure, and
(3) At high speed with nominal air flow. diagnostics.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
Feedforward Adaptive Control
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Feedforward is an open-loop, predictive control strategy
Heat exchanger operating limits:
designed
FWD: to anticipate and compensate for load changes.
It*water
usestemperature:
evaporator entering-water
max 100° C temperature as an
*absolute service pressure: min 1 bar/max 11 bars
indication of load change.
Accessories - Hot water coil:
This
*waterallows themin.
temperature: controller to respond
+2° C/max. 100° C faster and maintain
stable
*absoluteleaving-water temperatures.
service pressure: min 1 bar/max 11 bars

Soft Loading
The chiller controller uses soft loading except during
manual operation. Large adjustments due to load or
setpoint changes are made gradually, preventing the
compressor from cycling unnecessarily. It does this by
internally filtering the setpoints to avoid reaching the
differential-to-stop or the demand limit. Soft loading
applies to the leaving chilled-water temperature and
demand limit setpoints.

4
36 UNT-PRC002-GB
RLC-PRC045B-GB
Mechanical Specifications

Display Features Include: Hardwire Points


• Factory-mounted above the control panel door Microcomputer controls allow simple interface with
• UV Resistant touchscreen other control systems, such as time clocks, building
• -40°C to 70°C Operating temperature automation systems, and ice storage systems via
• I
 P56 rated
Sound power levels hardwire points. This means you have the flexibility
• CE certification to meet job requirements while not having to learn a
• Emissions:EN55011(Class B) complicated control system. Remote devices are wired
Discharge
• Immunity:EN61000(Industrial) from the control panel to provide auxiliary control
• 7” diagonal to a building automation system. Inputs and outputs
Measurement conditions:
• 800x480 pixels can be communicated via a typical 4–20 mA electrical
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
• TFT LCD @ 600 nits brightness signal, an equivalent 2–10 V dc signal, or by utilizing
long) fixed to its discharge opening.
• 16 bit color graphic display contact closures. This setup has the same features as a
• Display features:Fan stand-alone water chiller, with the possibilityOverall
Power level in dB(A), per Hz frequency band
of having
power
Unit• Alarms speed 125 250 500 additional
1000 optional
2000 features:
4000 8000 dB(A)
• Reports 1 55 50 42 37making control.
• Ice 37 31 30 46
FWD• 08Chiller settings 2 57 54 47 40 30 38 40 50
3 58 57 50 • External
42 chilled
32 water setpoint,
40 external
43 demand53limit
• Display settings 1 57 51 45 setpoint.
42 34 33 28 48
FWD• 10Graphing 2 58 54 48 45
• Chilled water38 39 reset.
temperature 35 51
• Support for 15 languages
3 60 58 50 48 40 42 39 54
• Programmable relays - available outputs are: alarm-
1 57 51 45 42 34 33 28 48
FWDFigure
12 4 – Picture TD7
2 58 54 48 latching,
45 alarm-auto
38 reset,
39 general alarm-warning,
35 51
3 60 58 50 chiller
48 limit mode,
40 compressor
42 running,
39 and Tracer
54
1 56 62 50 48
control. 39 38 36 56
FWD 14 2 61 66 55 53 47 46 45 60
3 63 69 58 BACnet
56 Interface
50 50 49 63
1 57 63 51 49 40 39 37 57
FWD 20 2 61 66 55 • Tracer
53 TD7 control
47 can be46configured45for BACnet60
3 63 69 58 communications
56 50 at the factory
50 or in 49
the field. This
63
enables the chiller controller to communicate on a
Intake BACnet MS/TP network. Chiller setpoints, operating
modes, alarms, and status can be monitored and
Measurement conditions: controlled through BACnet. Tracer TD7 controls
Measurements taken at the horizontal air intake. conforms to the BACnet B-ASC profile as defined by
ASHRAE 135-2004.
Fan Power level in dB(A), per• HzLfrequency
on Talk Communications
band Interface (LCI-C) Overall power
Unit speed 125 250 500
• T1000
he optional2000Lon Talk® Communications
4000 8000 dB(A)
Interface for
1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 Chillers
60 (LCI-C)
53 is available
53 factory or53field installed.
64
3 66 65 63 It 62
is an integrated
56 communication
55 board
57 that enables
67
1 62 58 55 the58 chiller controller
51 to 48
communicate 44over a LonTalk
61
FWDSystem
10 Integration
2 66 63 60 62 56 55 52 66
3 70 67 63
network.
65
The 59
LCI-C is capable
59
of controlling
57
and69
Stand-Alone Controls 1 62 58 55 monitoring
58 chiller
51 setpoints,
48 operating
44 modes, alarms,
61
FWDSingle
12 2 66 63
chillers installed in applications without a building 60 and62 status. The
56 Trane LCI-C
55 provides additional points
52 66
3 70 67 63 65
beyond 59
the standard 59
LONMARK ® defined
57 69
chiller
management system 1 are simple 66 to install65and control: 65 65 57 50 46 68
FWDonly
14 a remote auto/stop
2 for scheduling
73 is 72
required for69 profile
71 to extend
64 interoperability
59 and57support a broader
74
3 78 76
unit operation. Signals from the chilled-water pump 73 range
75 of system
69 applications.
64 These added
63 points
78 are
1 68 72 64 64
referred to as56open extensions.
52 50
The LCI-C 69
is certified
contactor
FWD 20
auxiliary,2
or a flow switch,
76
are wired
76
to the 68 71 65 61 61 75
chilled-water flow interlock.
3 Signals
78 from 79a time clock71or to74the LONMARK 69
Chiller 66
Controller Functional
66
Profile
78
some other remote device are wired to the external auto/ 8040 version 1.0, and follows LonTalk FTT-10A free
stop input. topology communications.
• A uto/Stop-A job-site provided contact closure turns the Modbus Interface Tracer TD7 control can be configured
unit on and off. for Modbus communications at the factory or in the field.
• External Interlock-A job-site provided contact opening This enables the chiller controller to communicate as
wired to this input turns the unit off and requires a a slave device on a Modbus network. Chiller setpoints,
manual reset of the unit microcomputer. This closure is operating modes, alarms, and status can be monitored
typically triggered by a job-site provided system such and controlled by a Modbus master device.
as a fire alarm.

UNT-PRC002-GB
RLC-PRC045B-GB 11
37
Mechanical Specifications
Technical Data
Tracer Summit Adaptive Frequency Drive (RTHD HSE)
The chiller plant control capabilities of the Trane Tracer RTHD HSE will fit an Adaptive Frequency Drive, factory
Summit™ building automation system are unequaled in mounted, tested and wired. Frequency converter will be
the industry. Trane’s depth of experience in chillers and chosen by the manufacturer basis on the present motor
controls
FWD makes us a well-qualified choice for automation
08 current at maximum
12 loading 20
of the unit, and
30 will drive45
Power
of supply
chiller plants using air-cooled RTAF(V/Ph/Hz)
chillers. Our chiller 230/1/50
the chiller start and ramp up, as long as the partial load
Capacities
plant automation software is fully pre-engineered
Cooling capacity on water (1) (kW)
and5,2 operation. 8,3 15 18,8 30,1
tested.
Heating capacity on water (2) (kW) 6,3 AFD enclosure will be IP54 as
11,9 standard, with
18,9 20,9 integrated
38,2
Fan motor (type) 2 x direct drive centrifugal
Required features: air cooling system, consisting in a fan below the AFD
Fan power input (3) (kW) 0,23 0,46 0,65 1,04 1,51
• Current
LonTalk/Tracer
amps (3) Summit Interface
(selectable
(A) option 1,1 frame, without2,2no obstacle to3,1 the air circulation
4,7 5,5
Start-up
with chiller) amps (A) 3,2 5,5 9,3 14,1 16,5
Air flow Harmonic Filter (optional)
• minimum
Building Control Unit (external device required)
(m /h) 490 AFD could be 980equipped with1400 an Harmonic1800 Filter, sized2700
3

• nominal
Sequences starting of chillers to optimize 3
(m /h) the overall
820 1650 2300 3000 4500
by the manufacturer in accordance with the compressor
maximumchiller plant energy efficiency 3
(m /h) 980 1970 2600 3600 5400
Main coil size, with a minimum capability of 5% THiD (Total
−− Individual chillers operate as base, peak, or
Water entering/leaving connections (type) harmonic Distortion).ISO Filter frame female
R7 rotating will have a minimum
swing based on capacity and efficiency (Dia) 3/4" 3/4" 1 1/2"
protection rate of IP23, and could built-in 1on
1/2"
the AFD1 1/2"
Electric −− Aheater
utomatically
(accessoryrotates individual
for blower only) chiller
Electricoperation power supply (V/Ph/Hz) 230/1/50 frame. 230/1/50 or 400/3/50 400/3/50 400/3/50 400/3/50
to equalize runtime and wear between
Heating capacity (kW) 2/4 8
Filter must be compliance 10 EMC standards
with 12 12
chillers
Hot water coil (accessory for blower only)
Heating −− Ecapacity
valuates (4) and selects the lowest (kW)
energy 6,3 EN 55011-1A. 12 17,4 22,4 34,5
G2 filter consumption alternative from an overall system
(filter box accessory) The purpose of harmonic filter will be to avoid
Quantity 2 2 2 2 2
perspective.
Dimensions ( LxWxth) (mm) 386x221x8
incremental heat losses in586x321x8
486x271x8
the installation (transformers,
586*421*8 586*621*8
• G4Rfilter egulatory
(filter boxCompliance
accessory) Documentation cables), keeping harmonic currents at low level so as to
• Quantity
Gathers information and generates the reports - avoid transformer
2 overload and2 high cable 2temperature. 2
Dimensions
mandated ( LxWxth)
in ASHRAE Guideline 3. (mm) - 486x264x48 586x314x48 586*414*48 586*614*48
Condensate pump (accessory)
• Water Easyflow Operation
(type) Options Centrifugal
- lift heightand Maintenance (l/h - mm) 24 - 500
• Not Remote
availablemonitoring
for FWD30 and and control
FWD45 Disconnect switch
• Sound Displays both speed)
level (L/M/H current operation conditions and Optional starter features include
Sound pressure level (5) (dB(A)) 36/40/43 38/41/44 46/50/53circuit breaker,
47/52/57 fused
47/52/58
scheduled automated control actions
Sound power level (5) (dB(A)) 46/50/53 disconnect switch,
48/51/54 non fused disconnect57/62/67
56/60/63 switch. 57/62/68
• Unit Concise
dimensions reports assist in planning for preventative
Width maintenance
x Depth and verifying performance (mm) The disconnect
890 x 600 1090 xswitch
710 is also
1290 mechanically
x 820 1290 xinterlocked
970 1290 xto
1090
Height (mm) 250 disconnect line 300power from the 350 starter before
450 the starter
650
Alarm notification
Shipped unit dimensions and diagnostic messages aid in quick door is open.
and
Widthaccurate
x Depth troubleshooting (mm) 933 x 644 1133 x 754 1333 x 864 1333 x 1008 1333*1133
Height (mm) 260 Nitrogen Charge 310 360 460 660
Unit-Mounted
Weight Start-Delta Starter (RTHD SE,(kg) HE, XE) 32 46 61 76 118
Colour Unit is shipped with a nitrogen
galvanisedholding
steel charge in lieu of
The starter is available
Recommended fuse size
in a Star-Delta configuration refrigerant (No oil charge).
closed transition,
Unit alone (aM/gI) factory-mounted and fully (A) pre-wired8/16 8/16 8/16 8/25 8/25
to the
Unit compressor
with electric heatermotor
(gI) and control panel.
(A) Starter
16 (2kW),25 Holding
will (4kW) 40 charge
(230V),3*16 (400V) 3*20 3*25 3*25
reduce 33% the RLA inrush current.
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°CUnit
DB/WBis shipped
- Nominal with a holding R134a charge and full oil
air flow
A(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB
factory-installed, factory-wired 600VA control charge.
- Nominal air flow
(3) At high speed with nominal air flow.
power
(4) Water transformer provides
entering/leaving temperature all°C,
90/70 unit control
air inlet power
temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement isInsulation
taken in the room containing the blower unit.
(120 VAC secondary) and UC800 module power (24 VAC
secondary). Optional
Heat exchanger operating starter features include circuit
limits:
All low temperature surfaces are covered with 19 mm of
FWD:
breaker, fused disconnect switch, non-fused disconnect armaflex (K=0.28), including the evaporator and water
*water temperature: max 100° C
switch. All the starter elements will
*absolute service pressure: min 1 bar/max 11 bars be enclosed in a IP54 boxes, suction line and motor housing .
panel, with hinged door to allow customer power input
Accessories - Hot water coil: Cupronickel condenser tubes
connection
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars Cupronickel condenser tubes are available for special
applications. 90/10 cupronickel tubes are ¾” diameter
and 0.035” wall thickness.
Programmable Relays (Alarm and Status)
Tracer UC800 provides a flexible alarm or chiller
status indication to a remote location through a hard
wired interface to a dry contact closure. Four relays
are available for this function, and they are provided
(generally with a Quad Relay Output LLID) as part of the
Alarm Relay Output Option. The events/states that can
be assigned to the programmable relays are listed in the
installation manual RLC-SVX018.

4
38 UNT-PRC002-GB
RLC-PRC045B-GB
Mechanical Specifications

External Base Loading External Current Limit Setpoint


Primarily for process control requirements, base loading Tracer UC800 will accept either a 2-10VDC or a 4-20mA
provides for immediate start and loading of a chiller input signal to adjust the current limit setpoint from a
up to an externally or remotely adjustable current limit remote location.
setpoint without
Sound power levels regard to differential to start or stop,
Percent Condenser Pressure Output
or to leaving water temperature control. This allows the
flexibility to prestart or preload a chiller in anticipation Tracer UC800 provides a 2-10 VDC analog output to
Discharge indicate percent High Pressure Cutout (HPC) condenser
of a large load application. It also allows you to keep a
chiller on line between processes when leaving water pressure.
Measurement conditions:
temperature control would normally cycle the unit. Percent HPC = (Condenser Pressure/High Pressure
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
Cutout Setpoint)*100
Summit
long) fixed toInterface
its discharge opening.
Tracer UC800 provides an optional interface between Compressor Percent RLA Output
Fan Power level in dB(A), per Hz frequency band Overall power
Unit
the chiller and a Trane
speed
Summit BAS.
125
A Communications
250 500
Tracer
1000
UC800 provides
2000
a 0-10
4000
Vdc analog
8000
outputdB(A)
to
interface LLID shall1be used to55provide «gateway»
50 42 indicate
37 %RLA of 37 compressor
31 starter average
30 phase
46
FWDfunctionality
08 between2 the Chiller
57 and Summit.
54 47 current.
40 2 to 10 30
Vdc corresponds
38 to 0 to
40120%RLA.50
3 58 57 50 42 32 40 43 53
LonTalk Communication
1 Interface
57 51 45 42 34 33 28 48
FWD 10 2 58 54 48 45 38 39 35 51
Tracer UC800 provides
3 an optional
60 LonTalk58 50 48 40 42 39 54
Communication Interface
1 (LCI-C)
57 between51the chiller 45
and 42 34 33 28 48
FWDa12
Building Automation
2 System58(BAS). An 54LCI‑C LLID shall
48 45 38 39 35 51
be used to provide 13«gateway»5660 58
functionality
62
50
between 50
the 48
48
40
39
42
38
39
36
54
56
FWDLonTalk
14 protocol and
2 the Chiller.
61 66 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Modbus Communication
1 Interface
57 63 51 49 40 39 37 57
FWDUC800
20 provides an2optional Modbus
61 66
Communication 55 53 47 46 45 60
3 63 69 58 56 50 50 49 63
Interface, fully integrated that shall be used to provide
“gateway” functionality between the Modbus protocol
Intake
and the Chiller.
Measurement conditions: Interface
BACnet Communication
Measurements takenan
UC800 provides atoptional
the horizontal
Modbus airCommunication
intake.
Interface , fully integrated that shall be used to provide
Fan Power level in dB(A), per Hz frequency band Overall power
Unit“gateway” functionality
speed between
125 the BACnet
250 protocol 500 1000 2000 4000 8000 dB(A)
and the Chiller. 1 56 55 55 53 46 45 42 57
FWD 08 2 63 62 60 60 53 53 53 64
Ice Making Control3 66 65 63 62 56 55 57 67
1 62 58 55 58 51 48 44 61
Tracer UC800 accepts
FWD 10 2
a contact66
closure input
63
to 60 62 56 55 52 66
initiate Ice Building.3 When in the70 ice building
67 mode, 63 65 59 59 57 69
the compressor will1 be fully loaded
62 (not given
58 a low 55 58 51 48 44 61
FWDsetpoint)
12 2
and will continue to 66
operate until 63 the ice 60 62 56 55 52 66
3 70 67 63 65 59 59 57 69
contacts open or the 1 return water
66 temperature
65 reaches
65 65 57 50 46 68
FWDthe
14 Ice Termination2Setpoint. If73terminated72on return 69 71 64 59 57 74
setpoint, Tracer UC8003 will not78allow the chiller
76 to restart
73 75 69 64 63 78
1 68 72 64 64 56 52 50 69
until
FWD 20
the ice making 2
contact is opened.
76 76 68 71 65 61 61 75
3 78 79 71 74 69 66 66 78
Ice Machine Contact
Tracer UC800 provides an output contact closure that
can be used as a signal to the system that ice building
is in operation. This relay will be closed when ice
building is in progress and open when ice building has
been terminated by either Tracer UC800 or the remote
interlock. It is used to signal the system changes required
to convert to and from ice making.
External Chilled Water Setpoint
Tracer UC800 will accept either a 2-10 VDC or a 4-20mA
input signal, to adjust the chilled water setpoint from a
remote location.

UNT-PRC002-GB
RLC-PRC045B-GB 11
39
Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader
in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of
advanced controls and HVAC systems, comprehensive building services and parts. For more information visit
www.Trane.com
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.

© 2018 Trane All rights reserved We are committed to using environmentally


conscious print practices that reduce waste.
RLC-PRC045B-GB March 2018