You are on page 1of 2

PROJECT: PROPOSED APARTMENT COMPLEX FOR MS.CLEARPOINT RESIDENCIES(PVT) LTD.

DATE: 2016-April-29
REVISION: 0

COLD WATER BOOSTER PUMP SIZING (WITHOUT FLUSHING)

Loading units per apartment

Appliance Loading units Nos Total

Wash basin 1 4 4
Shower-1 6 2 12
Shower -2 4 1 4
Bidet shower 1 4 4
Sink(Kitchen) 2 1 2
Total loading units per apartment 26

Total loading units per apartnet 26


Number of apartments to be boostered 10
Total loading units per floor 260 …………..(1)

Loading units for Pool toilet

Appliance Loading units Nos Total

Wash basin 1 1 1
Shower-1 6 2 12
Bidet shower 1 2 2
Total loading units for pool toilet 15

Total loading units for pooltoilet 15 …………..(2)

Total loading units for booster pump

Total loading units per floor 260


Total loading units for pooltoilet 15
Total loading units 275

Booster pump flowrate calculation

Desigh loading units 275


Flowrate 2.1 l/s
Design pump flowrate 2.1 l/s

Pumping line 50 mm at 1.2 m/s

Booster pump head calculation

End point pressure 20 m

Friction loss for longest path


50 mm pipe length 15 m
Friction loss 0.1 m/m
Head loss due to friction 1.5 m

Page 1 of 2
Component loss Qty
Strainer 1 0.073 m
Isolation valve 2 0.066 m
Non return valve 1 0.440 m

Design pump head 22.08 m


Design factor 5%

Differential pressure(1bar) 10 m
Pump head 33.18 m
Head gain due to gravity 13.8
Pump head 20 m

Booster pump-Summary

Q 2.1 l/s
H 20 m
PV 300 l

Page 2 of 2