Quick Connectors Incorporated (QCI) is a leading provider of wellhead and

QCI - About Us
packer penetrator systems for use with electrical submersible pumps (ESP). QCI is proud of
delivering quality, on-time products that meet our customers' requirements. We have over 20 years of
oil field experience installing our systems worldwide with a track record of excellence and reliability.
QCI electrical penetrator systems eliminate the need for cable splicing, saving hours of costly rig time,
and increasing reliability by reducing exposure to reactive agents.
QCI offers various types of wellhead penetrator systems designed to work with a variety of
applications to meet customer requirements and needs. QCI wellhead penetrator systems can be
designed to fit new or existing wellheads (concentric or non-concentric applications), or to
accommodate wellhead applications that were not originally designed for use with ESP applications.
QCI wellhead penetrators can be easily retrofitted to replace existing competitor type mandrel
penetrator systems.
QCI also offers specialty penetrator systems for applications requiring the use of BOP Cans, ESP
Packers, dual or triple completions, and heater applications. These applications can also be retrofitted
to replace existing competitor systems.
All of the QCI penetrator systems are suitable for 375°F/ 190°C, and can be fitted to all ESP pump
cables and electrical requirements currently in use (up to 5000 Volts and 257Amps).
QCI operates under the ISO 9001-2000 requirements. All of the QCI wellhead penetrator
systems are third party approved by Factory Mutual (FM) and CSA. The QCI products are designed to
meet the highest classifications for safety compliance within the United States for operation of
electrical equipment in hazardous/explosive locations (Class I, Divisions 1 & 2).
We pride ourselves on quick delivery and excellent engineering support. QCI provides on-site
installation (domestic and international) and can provide technical support through highly trained
international representatives. Complete in-house training simulating wellhead and packer penetrator
installation can be provided for customers who wish to install QCI equipment. Training videos and
installation procedures are available upon request.

CI –Unique Adaptable Global

1
P3000-2

P3000-2 Mini Mandrel Cable Gland


P3000-2 Canned Pump Coupling (CPC) Surface Power Cable (CLX)
Wellhead Penetrator System Surface Conduit System
Breather Vent/Detonation
“Boll Weevil Type” Arrestor

Features/Benefits Specifications
 Eliminates cable splices in the wellbore.  FM & CSA Approved
 Designed to eliminate large mandrel type penetrators.  Voltage: Dependant on Max. Rating of ESP Cable
 Available as a P3000-2F for flat cable.  Amperage: Dependant on Max. Rating of ESP Cable
 ESP cable is stripped and the three cable wires are  Pressure: 5,000 psi API WP (13,500 psi Proof Test)
separated and sealed off with an elastomer sealing  Temp: 375° F, 190° C
element.
 Hazardous Area: Class I, Divisions 1 & 2 Group D
 Reusable surface conduit system suitable for hazardous
locations.
 UL listed surface cable (CLX) is terminated and sealed
in the conduit system for required length to reach the
power supply.
 Permits the use of shielded and non-shielded cable.

2
P3000-2F
Flat-to-Round Transition Collar Breather Vent/Detonation
P3000-2 Mini Mandrel Arrestor
P3000-2F Wellhead Penetrator Canned Pump Coupling (CPC) Cable Gland
System “Seal Sub” Type Surface Conduit System Surface Power Cable (CLX)

Features/Benefits Specifications
 Eliminates cable splices in the wellbore.  FM & CSA Approved
 Designed to eliminate large mandrel type penetrators.  Voltage: Dependant on Max. Rating of ESP Cable
 Available as a P3000-2 for round cable.  Amperage: Dependant on Max. Rating of ESP Cable
 ESP cable is stripped and the three cable wires are  Pressure: 5,000 psi API WP (13,500 psi Proof Test)
separated and sealed off with an elastomer sealing
 Temp: 375° F, 190° C
element.
 Hazardous Area: Class I, Divisions 1 & 2 Group D
 Reusable surface conduit system suitable for
hazardous locations.
 UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the power supply.
 Permits the use of shielded and non-shielded cable.

3
P3000-2DM

Upper Pigtail (Competitor) Canned Pump Coupling (CPC)


Mandrel (Competitor) Surface Conduit System
Lower Pigtail (Competitor) Breather Vent/Detonation
QCI Dummy Mandrel Arrestor
P3000-2DM (Replaces items 1-3) Cable Gland
Wellhead Penetrator System P3000-2 Mini Mandrel Surface Power Cable (CLX)

Features/Benefits Specifications
 Eliminates cable splices in the wellbore.  FM & CSA Approved
 Available as a P3000-2FDM for flat cable.  Voltage: Dependant on Max. Rating of ESP Cable
 ESP cable is stripped and the three cable wires are  Amperage: Dependant on Max. Rating of ESP Cable
separated and sealed off with an elastomer sealing  Pressure: 5,000 psi API WP (13,500 psi Proof Test)
element.
 Temp: 375° F, 190° C
 A QCI dummy mandrel is provided to fit the existing
wellhead, replacing the competitor’s mandrel.  Hazardous Area: Class I, Divisions 1 & 2 Group D
 Reusable surface conduit system suitable for hazardous
locations.
 UL listed surface cable (CLX) is terminated and sealed
in the conduit system for required length to reach the
power supply.
 Permits the use of shielded and non-shielded cable.

4
P3000-1
P3000-1FR
Flat-to-Round Transition
) Collar Surface Splice Boot
Feed-thru Assembly Ground Wire Connector
Bottom Seal Fittings Breather Vent/Detonation
Canned Pump Coupling (CPC) Arrestor
P3000-1 Bracket Assembly Cable Gland
Wellhead Penetrator System Surface Conduit System Surface Power Cable (CLX)

Features/Benefits Specifications
 Eliminates cable splices in the wellbore.  FM & CSA Approved
 Adaptable with either concentric or eccentric  Voltage: Dependant on Max. Rating of ESP Cable
wellhead completions, and can be run in small  Amperage: Dependant on Max. Rating of ESP Cable
annular spaced wells.
 Pressure: 3,000 psi API WP (6,000 psi Proof Test)
 Three flexible fittings with Swagelok connections
seal off the penetrator above and below the tubing  Temp: 375° F, 190° C
hanger.  Hazardous Area: Class I, Divisions 1 & 2 Group D
 ESP cable is stripped and the three cable wires are
separated and sealed off with an elastomer sealing
element.
 Reusable surface conduit system suitable for
hazardous locations.
 UL listed surface cable (CLX) is terminated and
sealed in the conduit system for a required length
to reach the power supply.
 Permits the use of shielded and non-shielded cable.
5
P5000 Model 1

Triskelion Surface Conduit System


Male & Female Connectors Breather Vent/Detonation
Bottom Seal Fittings Arrestor
P5000 - Model 1 Bracket Assembly Cable Gland
Wellhead Penetrator System Canned Pump Coupling (CPC) Surface Power Cable (CLX)

Features/Benefits Specifications
 Eliminates cable splices in the wellbore.  FM & CSA Approved
 Adaptable for concentric wellhead completions,  Voltage: 5000 VAC, 3 Phase
and can be installed in small annular spaced wells.  Amperage: 150 Amp and 190 Amp versions available
 Three flexible fittings with Swagelok connections  Pressure: 5,000 psi API WP (13,500 psi Proof Test)
seal off the penetrator above and below the tubing
hanger.  Temp: 375° F, 190° C
 Reusable surface conduit system suitable for  Hazardous Area: Class I, Divisions 1 & 2 Group D
hazardous locations.
 UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the motor control panel.
 Permits the use of shielded and non-shielded cable.

6
P5000-Dual ESP
Triskelion Breather Vent/Detonation
Male & Female Connectors Arrestor
Bottom Seal Fittings Cable Gland
Bracket Assembly Surface Power Cable (CLX)
P5000 Dual ESP Canned Pump Coupling (CPC)
Wellhead Penetrator System Surface Conduit System

Features/Benefits Specifications
 Eliminates cable splices in the wellbore.  FM & CSA Approved
 Adaptable for concentric wellhead completions,  Voltage: 5000 VAC, 3 Phase
and can be installed in small annular spaced wells.  Amperage: 150 Amp and 190 Amp versions available
 Three flexible fittings with Swagelok connections  Pressure: 5,000 psi API WP (13,500 psi Proof Test)
seal off the penetrator above and below the tubing
hanger.  Temp: 375° F, 190° C
 Reusable surface conduit system suitable for  Hazardous Area: Class I, Divisions 1 & 2 Group D
hazardous locations.
 UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the motor control panel.
 Permits the use of shielded and non-shielded
cables.

7
Packer Penetrator Systems Manifold Bushing Examples

Standard 3-Hole

Multiple Ports for


Additional Control Lines

Multiple Port Type Dual String Type


Packer Packer

ESP cable Manifold Bushing


Triskelion Lower Male & Female Connectors
Male & Female Connectors Triskelion Upper
Seal Fittings

Features/Specifications
 No splices above and below the packer.
 A mainfold bushing is provided for dual string packers, and
can accommodate extra ports for control lines, if necessary.
 For small diameter and multiple port packers, the
penetrators pass through 3 individual ports through the
packer.

 Voltage: 5000 VAC, 3 Phase

8 Multiple Port Dual String





Amperage: 150 Amp and 257 Amp versions available
Pressure: 5,000 psi API WP (10,000 psi Proof Test)
Type Packer Type Packer  Temp: 375° F, 190° C