SECOND FLOOR BEAM DESIGN CALCULATION

Group : G3
Beam No : B5
Analysis Reference (Member) 3.9m : 30
Beam Length : 3500 mm
Breadth (B) : 250 mm
Depth (D) : 350 mm
Effective Depth (d) : 280 mm
Design Code : ACI 318M - 2011
Beam Type : Ductile Beam (Special Frame)
Grade Of Concrete (f'c) : C21 N/sqmm
Grade Of Steel : Fy230 N/sqmm
Clear Cover (Cmin) : 40 mm
Es : 2x10^5 N/sqmm
Mubal : 104.24 kNm
As,min (flex) (B) : 426.09 sqmm
As,nominal (Bn) : 91 sqmm
As,min(user input)(B') : 91 sqmm

For Longitudinal Reinf


Beam Bottom Beam Top
Left Mid Right Left Mid Right
Critical L/C - Analysis 15 7 17 9 17 7
Critical L/C - RCDC 11 3 13 5 13 3
Mu (kNm) 25 19.05 20.76 45.58 14.94 47.3
As (flex) (sqmm) (C) 449.92 339.18 370.87 853.35 264.29 888.77
Asc (flex) (sqmm) (A) - - - - - -
Tu (kNm) - - - - - -
Tcr/4 (kNm) - - - - - -
Al, min(sqmm)(Tor.) - - - - - -
Al (sqmm) (Tor.) (E) - - - - - -
Al (Dist) (sqmm) (D) - - - - - -
Ast (sqmm) 449.92 426.09 603.18 853.35 351.5 888.77
AstPrv (sqmm) 603.18 603.18 603.18 942.48 402.12 1206.36
3-#16 3-#16 3-#16 3-#16 2-#16 3-#16
Reinforcement
3-#12 3-#16

Note: Calculation of Ast

Ast = Max {B, C+D, A+D} (for Mu > 0 and C x 1.33 > B)
Ast = Max{B', C x 1.33 + D, A+D} (for Mu > 0 and C x 1.33 < B)
Ast = Bn (for Mu = 0)
Where,
Compression reinforcement required for
A = Asc (flex) =
bending moment
B = As,min (flex) = Min area of flexural reinforcement
Bn = As,nominal = Nominal area of reinforcement
Total area of longitudinal reinforcement
C = As (flex) =
calculated at a given section
D = Al (Dist) = reinforcement at section considered
Max(Al,min (Tor), Al (Tor)) x ((2B) / (2B +
Ast (Dist) (sqmm) =
2D))

For Transverse Reinf


Left Mid Right
Critical L/C - RCDC 1 1 1
PtPrv (%) 1.346 0.862 1.723
Vu (kN) 19.9 14.94 22.09
Mu-Sect (kNm) 12.49 0.6 16.32
VD+L (kN) 20.68 0 20.48
Mh (kNm) 67.64 0 83.63
Ms (kNm) 45.19 0 45.19
Sway-Right (kN) 20.21 0 61.38
Sway-Left (kN) 56.5 0 15.34
Vu-Sway (kN) 56.5 0 61.38
Vud (kN) 56.5 0 61.38
Φ Vc (kN) 35.08 36.95 35.46
Vs (kN) - - -
Av (sqmm/m) 380.43 380.43 380.43
Tu (kNm) 0 0 0
Aoh (sqmm) - - -
At (sqmm/m) - - -
Legs 2 2 2
Stirrup Rebar 10 10 10
At Torsion (sqmm/m) - - -
Av Total Reqd (sqmm/m) 380.43 380.43 380.43
Asv Reqd (sqmm/m) 416.48 380.44 473
SCalc (mm) 100 140 100
SPrv (mm) 100 140 100
Av Total Prv (sqmm/m) 1570.8 1122 1570.8

Maximum Spacing Criteria

Basic
Spc1 =d/2 = 140 mm
Spc2 = 300 mm

For Ductility (Special Frames)


Left Section, Right Section
=
Spc3 = 6 x Small Longitudinal Dia 72 mm
Spc4 = d / 4 = 70 mm
Spc5 = 150 mm
Provided Spacing = 100 mm

Mid Section
Provided Spacing = 140 mm

Skin reinforcement

Beam Width = 250 mm


Beam Depth = 350 mm
Depth = 350 <= 900, Hence Skin Reinforcement is not required.