Anchor Bolt Design, Is Code LSD
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
P
Mx
t
Bpb
Y1/3 100 mm
Y1
con
T
C
Calculation of bolt along Z- axis
Node No. 964 Load Case 112
B
Axial force,AP 1150 kN
Moment about X-axis, Mx 380 kNm
Moment about Z-axis, Mz 15 kNm
Horizontal Force along X- axis , Fx 15.6 kN
Horizontal Force along Z- axis , Fz 85 kN
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 2.12 N/mm2
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -0.52 N/mm2
Dia of bolt 40 mm
Gross area provided 1257 mm2
Net area provided 1006 mm2
Tensile capacity of each bolt based on tensile strength 337105 N
Tensile capacity of each bolt based on concrete break out failure 10872949 N
So, Effective Tensile capacity 337105 N
No. of bolt per side 1.00 nos
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
P
Mz
t
Bpb
Y1/3 100 mm
Y1
con
T
A B
C
Calculation of bolt along Z- axis
Node No. 990 Load Case 129
Axial force, P 4503 kN
Moment about X-axis, Mx 514 kNm
Moment about Z-axis, Mz 2430 kNm
Horizontal Force along X- axis , Fx 600 kN
Horizontal Force along Z- axis , Fz 724 kN
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 11.54 N/mm2
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -5.28 N/mm2
Dia of bolt 40 mm
Gross area provided 1257 mm2
Net area provided 1006 mm2
Tensile capacity of each bolt based on tensile strength 337105 N
Tensile capacity of each bolt based on concrete break out failure 10872949 N
So, Effective Tensile capacity 337105 N
No. of bolt per side 4.00 nos
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
P
Mz
t
Bpb
Y1/3 100 mm
Y1
con
T
A B
C
Calculation of bolt along X- axis
Node No. 983 Load Case 129
Axial force, P 4076 kN
Moment about X-axis, Mx 1657 kNm
Moment about Z-axis, Mz 12 kNm
Horizontal Force along X- axis , Fx 10 kN
Horizontal Force along Z- axis , Fz 412 kN
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 8.57 N/mm2
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -2.91 N/mm2
Dia of bolt 40 mm
Gross area provided 1257 mm2
Net area provided 1006 mm2
Tensile capacity of each bolt based on tensile strength 337105 N
Tensile capacity of each bolt based on concrete break out failure 3632593 N
So, Effective Tensile capacity 337105 N
No. of bolt per side 2.00 nos
Portion
Considered for
plate design
X (+)
Mx (-)
Mz (-)
Z (+)
Dia of bolt 40 mm
Gross area provided 1257 mm2
Net area provided 1006 mm2
Tensile capacity of each bolt based on tensile strength 337105 N
Tensile capacity of each bolt based on concrete break out failure 9687500 N
So, Effective Tensile capacity of each bolt 337105 N
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
P
Mz
t
Bpb
Y1/3 100 mm
Y1
con
T
A B
C
Calculation of bolt along Z- axis
Node No. 990 Load Case 128
Axial force, P 1491.1
Moment about X-axis, Mx -2.4
Moment about Z-axis, Mz 1196.3
Horizontal Force along X- axis , Fx 260.5
Horizontal Force along Z- axis , Fz 0.8
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 5.24
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -2.88
Dia of bolt 40
Gross area provided 1257
Net area provided 1006
Tensile capacity of each bolt based on tensile strength 337105
Tensile capacity of each bolt based on concrete break out failure 4059698
So, Effective Tensile capacity 337105
No. of bolt per side 2.00
mm
mm
mm
mm
mm
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
N/mm2
Size is O.K.
B
128
kN
kNm
kNm
kN
kN
N/mm2
N/mm2
mm
mm
mm
kN
mm
mm2
mm2
N
N
N
nos
B
mm
OK
OK
OK
B
OK
B
3.4 Design of Base Plate
3.4.1 Design of Base Plate C1
Portion
Considered for
plate design
X (+)
Mx (-)
(+)Mz (-)
Z
P
Mx
t
Bpb
Y1/3 100 mm
Y1
con
T
A B
C
Calculation of bolt along Z- axis
Node No. 990 Load Case 128
Axial force, P 1150.0 kN
Moment about X-axis, Mx 380.0 kNm
Moment about Z-axis, Mz 15.0 kNm
Horizontal Force along X- axis , Fx 15.0 kN
Horizontal Force along Z- axis , Fz -85.0 kN
Max Bearing Pressure, smax =P/A+6xMx/(Lbp x Bbp2 ) 2.21 N/mm2
Min Bearing Pressure, smin =P/A-6xMx/(Lbp x Bbp2 ) -0.39 N/mm2
Dia of bolt 40 mm
Gross area provided 1257 mm2
Net area provided 1006 mm2
Tensile capacity of each bolt based on tensile strength 337105 N
Tensile capacity of each bolt based on concrete break out failure 4059698 N
So, Effective Tensile capacity 337105 N
No. of bolt per side 1.00 nos