You are on page 1of 3

Connection Deisgn between Rafter & Rafter

Main Frame at Grid-5,Column-Rafter Junction Node-324(Ref: SAAD) Code: IS:800-2007)


Design of Moment connection Tensile stess area= 0.78*3.14/4*d^2
Nominal Dia of anchor bolt,db= 20 mm 244.92
Gross Area of the bolt, Asb= 314 mm2
Net Area of the bolt, Anb= 244.92 mm2
Fillet weld size,W= 5 mm
Throat size = 3.54 mm
Number of bolt, n= 4
Depth of the connected beam, d= 750 mm
Width of the beam flange, bf= 225 mm
Thickness of the beam flange, tf= 10 mm
Thickness of the beam web, tw= 8 mm
Shear force, V= 116 KN
Bending moment, M= 312 KN-m
Tensile Axial Force, T= 53 KN
Stiffener Condition, = With Three veritical+one horizontal
Yield stress of materials,Fy= 330 mpa
Grade of bolt, = 8.8
Ultimate tensile strength of bolt, fub= 800 mpa
Yield stress of the bolt, fvb= 640 mpa

Bolt Design:

Shear Check

Factored shear force in bolt, 'Vsb' ≤ Shear design strength of the bolt, 'Vdsb' s

Factored shear forec per bolt, 'Vsb'= Shear force/2n 14.5 KN

Shear design strength of the bolt, Vdsb= Vnsb/Ymb nn= 1


where, Vnsb= fub/3^2(nn Anb+ns Asb)= 113123.70234 N ns= 0 Cl: 10.3.3 : IS-800:2007
113.12370234 kN Ymb= 1.25
hence, Vdsb= 90.498961875 kN

Tensile Check
Flange force, Ff= M/d+T/2= 442.5 KN-m
Tension per bolt, Tb=Flange Force/n= 110.625 KN-m
Factored Tensile force in bolt, 'Tb' ≤ Tensile strength of the bolt, 'Tdb'
Factored tensile forec in bolt, 'Tb'= 110.625 kN
Tensile strength of the bolt, 'Tdb'= Tnb/Ymb
where, Tnb= 0.9*fub*An < fyb*Asb*(Ymb/Ymo)

Now, 0.9*fub*An = 176342.4 N


176.3424 kN
fyb*Asb*(Ymb/Ymo)= 228363.63636 N Ymb= 1.25
228.36363636 kN Ymo= 1.1
considering minimum of two, so adopt, Tnb= 176.3424
therfore, Tdb= 141.07392

Combined Shear and Tension Check: (Also known as unity check)

(Vsb/Vdb)^2+(Tb/Tdb)^2 = 0.640583541 ≤ 1 Hence ok


Summary:
Provide, 8 nos 20 dia bolt
Beam L/C Node Axial Force kN Shear-Y kN Shear-Z kN Torsion kN-m
324 -122.161 -41.992 0 0
11 324 53.42 116.09 0 0
Moment-Y kN-m Moment-Z kN-m
0 312.617
0 312.617