BBU3910 Commissioning Guide

Figure 1. BBU3910 G*U Base Station

Download the last Java version:

Connect to the usb port of the UMPT board using a RJ45-USB converter:
The BBU IP default is 192.168.0.49. Put the laptop in the same IP segment with mask 24:

Verify ping between BBU and Laptop:


Before to access to the BBU, must put the BBU’s IP in the exception site list from Java:

Add the BBU IP using ‘http://’ and ‘https://’.

For access to the BBU, use internet explorer and to put BBU's IP 192.168.0.49, click on ‘Continue to this
website (not recommended)’:
Log in to the BBU, put the next information:

User name: admin


Password: hwbs@com

Access to the MML, can select MML tab or the MML icon:
Check the site version, write the ‘LST VER’ command and click on “assit” and then “Exec” :

The version should be set like this:


Uploading the site’s script

Download the FTP server from ‘FTP Tool’ tab:

Click on the option 1 and then on the option 2

The FTP folder is allocated automatically in ‘C:’


Save the site’s script in the FTP folder:

Start the SFTP Server:

Check the SFTP is turn on:


Double click on the FTP icon:

Password is the same used for to log in to the BBU: hwbs@com

Put in ‘Working directory:’ the path where is saved the script just copy from ‘C:’ and click on ‘OK’:

Change the password the FTP.

Go back to the site interface, select “Device Maintenance” tab:

Click on ‘BTS Maintenance’ tab:


Choose the ‘Data Configuration Data File’ and double click on it:

Fill up ‘Parameter Settings’, put the next information:

FTP Server IP: the laptop’s IP was configured it:

User Name: the same used for log in to the BBU:

Destination File Name: Select ‘Browse’ and select the path where the script is saved:

Password: set the password for the FTP:


Verify if the site has correctly upload, write ‘LST NODEBFUNCTION’ command: