Air only pressure drop

DO NOT USE THIS METHOD FOR DETAIL DESIGN – ALWAYS CONSULT A REPUTABLE SUPPLIER FOR DETAIL DES

WARNING domain of applicability : This model is o


Design data
Transport by Pressure
Material Test
Line capacity kg/h 30000
Assumed pressure drop mbar 750
Minimum air conveying velocity m/s 14.2
Recommended pick-up velocity m/s 17.04
Gas nature Air
Molecular mass M g/mol 2.90E+01
Air viscosity mu_g Pa.s 1.80E-05
Temperature at compressor discharge Ta °c 2.70E+01
Pressure at compressor discharge p bar g 0.75
Specific weight of gas at compressor discharge r_g1 kg/m3 2.0
Pressure at reception p2 bar g 0
Specific weight of gas at compressor discharge r_g1 kg/m3 1.2
Required volumetric throughput at pick-up m3/h 1927.2
Compressor air mass flowrate ma kg/h 3949.0
kg/s 1.10
7.59688878
265.2582385
Pipe layout - please fill other spreadsheet
Pipe diameter d m 0.2
Pipe roughness e mm 0.1
Pipe horizontal length 110
Pipe vertical length 25
Number of bends 5
Pipe length L m 185

Copyright www.PowderProcess.net

The content of PowderProcess.net is copyrighted but no warranty nor liability is ensured. The content of this site is to be seen as a help and important information and calcula
user must always respect all applicable regulation. The use of the information is at the u

Page 1
Air only pressure drop

Pressure
Vacuum

Page 2
Air only pressure drop
PPLIER FOR DETAIL DESIGN

pplicability : This model is only valid in LEAN PHASE


Air velocity
Air velocity at compressor discharge C1 m/s 17.16901714
Air velocity at end of pipe C2 m/s 30.04578
Mean air velocity C m/s 23.60739857

Friction coefficient
Friction coefficient lambda - 0.004484234
Reynolds number Re - 4.21E+05
f (Moody) 0.017936934 1.90E-05 1.613982E-32
A 1.56579E+21 1.66E-05 0.000135
B 1.58099E-17
0.004484234

Psi 16.591664256

Pressure Conveying
Dpa bar 0.08453995 (air only pressure drop corrected with ave
p bar 1.74360143 (abs pressure at blower discharge)
DPcApproximate method, DO NOT USE
bar 0.73 (actual pressure with product)
FOR DETAIL DESIGN. ALWAYS
CONSULT A REPUTABLEVacuum Conveying
DpaCOMPANY bar 0.02917695 (air only pressure drop)
DPc bar 0.41 (actual pressure with product)

help and important information and calculation must always be double checked by the user through the quality procedure of his organization or by checking another source. The
ation. The use of the information is at the user and its organization own risk and own cost.

1740630330

Page 3
Air only pressure drop
P2^2 10266755625
109578.21843
31090505625
171318.05303
Pressure drop Pipe only DP Pa 8253
DP bar 0.08

1740630330
Pressure drop actual pipe Pa 8253
bar 0.08

Page 4
Air only pressure drop

FANNING

ir only pressure drop corrected with average air velocity)


bs pressure at blower discharge)
ctual pressure with product)

ir only pressure drop)


ctual pressure with product)

Page 5
Air only pressure drop

8464.882269
0.084648823

Page 6