You are on page 1of 2

iBreeze Series

25S/25A/25ST/25STA/30ST
BPAP

‧ Unique 5 inches touching technology supported with


knob navigation eliminate all barriers between seeing
and using.

‧ With the help of timely waveform display function, more


respiratory specifics of patient can be presented to the
clinicians.

‧ Advanced ventilation algorithm in synchronization gives


patient a real brilliant experience of free breath.

‧ CSS (Cluster scheme setting) represents abundant


representative pre-setting parameters. Caregiver can
easily select the right option for particular patient and
make the necessary changes at any time while required.
iBreeze Series
BPAP
Basic information Circuit compensation

Model 25S/25A/25ST/25STA/ Value-added functions


30ST
Auto screen luminance adjustable
Intended use
OSA, respiratory Energy saving mode
insufficiency Time and alarm clock
Unit setting
Use type weight above 30 kg
Multi-language setting
Physical characteristics Performance self-examination
Patient report on main screen
Weight 1.6 kg
Size Sp02,PR
23.8 x 17.8 x 12.8 cm
Screen 5 inches, color,
touch screen
Humidity function
Noise level (ISO80601-2-70) ≤28dB Integrated humidifier
Auto humidity
Treatment parameters Preheating
Mode Heated tube
25S 25A 25ST 25STA 30ST Anti-leakage in inclined water tank position
CPAP, CPAP, CPAP, CPAP, CPAP, Water level detection
S S, S, S, S, Intelligent tube drying
auto S S/T auto S auto S
T auto S/T S/T Data management
T T
Data storage in main unit(1 year statisticaldata,1 Week
E-COMP* 4-20 cmH20
high resolution data)
CPAP pressure range 4-25 cmH20
SD card high-resolution data storage (10 years)
IPAP pressure range 4-30 cmH20
Wireless transmission (WIFI, GPRS)
EPAP pressure range 4-25 cmH20
Multi platform synchronous data sharing for patients
EVAPS
and clinicians (Android, iOS, Web)
Static pressure accuracy 0.5cmH20
Dynamic pressure accuracy 1cmH20
Others
Respiratory rate 5-30 bpm
(Backup frequency) IP Level
Rise Time 150-900 ms
Inspiratory trigger sensitivity Auto, 1-5 Accessories
Expiratory trigger sensitivity Auto, 1-5
SD card Standard
CSS (Cluster scheme setting) Mask pillow Opitonal
Nasal mask Standard
Comfort parameters Pull face mask Opitonal
Respiratory event detection Heated tube Opitonal
Ramp Tube(15 mm diameter) Standard
Auto ramp Tube(19 mm diameter) Opitonal
IPR (Intelligent pressure release) Heated tube(19 mm diameter) Opitonal
Auto altitude adjustable SpO2 Opitonal
Leakage compensation Communication module Opitonal
Auto on/off RollingStand Opitonal
Mask Fit ResAssist intelligent cloud system Opitonal

* E-COMP can help new patients gradually adapt the prescribed pressure during first month by using innovative pressure accumulation algorithm.
** R-Care allows patients to start from 95% of the therapeutic level yesterday in APAP mode to reduce the incidence of predormitium respiratory events.

Resvent Medical Technology Co., Ltd.


ADD: Room-602, Building B&C Gaoxinqi Industrial Park, Liuxian No.1, Road XingDong community, Bao'an Shenzhen, PEOPLE'S REPUBLIC OF CHINA
Fax: 0086-755-23027370 Tel: 0086-755-23027370-808
Mail: Web: www.resvent.com