No. Description of Material / Layer Name of Tests Minimum frequency of test No. of Tests conducted Total Pass
Name during month Test
4280 1000 1000 144 CONCRETE - M40 WORKABILITY OF FRESH CONCRETE (SLUMP TEST) EACH LOAD
640 640
4280 1000 1000 145 CONCRETE - M40 CUBE STRENGTH OF CONCRETE - 7 DAYS AS PER TABLE 1700-9 OF MORTH
573 573
4280 1000 1000 146 CONCRETE - M40 CUBE STRENGTH OF CONCRETE - 28 DAYS AS PER TABLE 1700-9 OF MORTH
351 351
4280 1000 1000 147 CONCRETE - M40 PEMLIABILITY TEST - (THIRD PARTY TEST) AS PER REQUIREMENT
0 0
4280 1000 1000 148 CONCRETE - M45 WORKABILITY OF FRESH CONCRETE (SLUMP TEST) EACH LOAD
0 0
4280 1000 1000 149 CONCRETE - M45 CUBE STRENGTH OF CONCRETE - 7 DAYS AS PER TABLE 1700-9 OF MORTH
0 0
4280 1000 1000 150 CONCRETE - M45 CUBE STRENGTH OF CONCRETE - 28 DAYS AS PER TABLE 1700-9 OF MORTH
0 0
4280 1000 1000 151 CONCRETE - M45 PEMLIABILITY TEST - (THIRD PARTY TEST) AS PER REQUIREMENT
0 0
4280 1000 1000 152 CONCRETE - M50 WORKABILITY OF FRESH CONCRETE (SLUMP TEST) EACH LOAD
0 0
4280 1000 1000 153 CONCRETE - M50 CUBE STRENGTH OF CONCRETE - 7 DAYS AS PER TABLE 1700-9 OF MORTH
0 0
4280 1000 1000 154 CONCRETE - M50 CUBE STRENGTH OF CONCRETE - 28 DAYS AS PER TABLE 1700-9 OF MORTH
0 0
4280 1000 1000 155 CONCRETE - M50 PEMLIABILITY TEST - (THIRD PARTY TEST) AS PER REQUIREMENT
0 0
4280 1000 1000 156 DRY LEAN CEMENT CONCRETE (DLC) GRADATION / SIEVE ANALYSIS DAILY WHEN EVER CONCRETE PRODUCTION
6 6
4280 1000 1000 157 DRY LEAN CEMENT CONCRETE (DLC) SILT CONTENT BY WEIGHT ONE PER SOURCE, WEEKLY
14 14
4280 1000 1000 158 DRY LEAN CEMENT CONCRETE (DLC) SILT CONTENT BY VOLUME DAILY WHEN EVER CONCRETE PRODUCTION
8 8
4280 1000 1000 159 DRY LEAN CEMENT CONCRETE (DLC) WATER ABSORPTION & SPECIFIC GRAVITY DAILY WHEN EVER CONCRETE PRODUCTION
0 0
4280 1000 1000 160 DRY LEAN CEMENT CONCRETE (DLC) AGGREGATE IMPACT VALUE (AIV) ONE PER SOURCE & MONTHLY SUBSEQUENTLY
4 4
4280 1000 1000 161 DRY LEAN CEMENT CONCRETE (DLC) COMBINED FLAKINESS & ELONGATION INDEX ONE PER SOURCE & MONTHLY SUBSEQUENTLY
5 5
4280 1000 1000 162 DRY LEAN CEMENT CONCRETE (DLC) COMPRESSIVE STRENGTH 5 CUBES WHEN EVER CONCRETE PRODUCTION
45 45
4280 1000 1000 163 DRY LEAN CEMENT CONCRETE (DLC) DENSITY OF COMPACTED LAYER WHEN EVER DLC DONE AT SITE
15 15
4280 1000 1000 164 DRY LEAN CEMENT CONCRETE (DLC) MOISTURE CONTENT WHILE LAYING WHEN EVER DLC DONE AT SITE
15 15
4280 1000 1000 165 DRY LEAN CEMENT CONCRETE (DLC) DELETERIOUS CONTENT - (THIRD PARTY TEST) ONE PER SOURCE
0 0
4280 1000 1000 166 DRY LEAN CEMENT CONCRETE (DLC) SAND EQUIVALENT VALUE - (THIRD PARTY TEST) ONE TEST PER SOURCE AND WHENEVER CHANGE IN THE QUALITY OF AGGREGATE
0 0
4280 1000 1000 167 DRY LEAN CEMENT CONCRETE (DLC) SOUNDNESS TEST - (THIRD PARTY TEST) INITIALLY FOR SOURCE APPROVAL & MONTHLY SUBSEQUENTLY
0 0
4280 1000 1000 168 DRY LEAN CEMENT CONCRETE (DLC) ALKALI-AGGREGATE REACTIVITY - (THIRD PARTY TEST) INITIALLY FOR SOURCE APPROVAL & MONTHLY SUBSEQUENTLY
0 0
4280 1000 1000 169 DRY LEAN CEMENT CONCRETE (DLC) DLC MATERIAL - (THIRD PARTY TEST) AS PER REQUIREMENT
0 0
4280 1000 1000 170 PAVEMENT QUALITY CONCRETE (PQC) GRADATION / SIEVE ANALYSIS DAILY WHEN EVER CONCRETE PRODUCTION
8 8
4280 1000 1000 171 PAVEMENT QUALITY CONCRETE (PQC) SILT CONTENT BY WEIGHT ONE PER SOURCE, WEEKLY
14 14
4280 1000 1000 172 PAVEMENT QUALITY CONCRETE (PQC) SILT CONTENT BY VOLUME DAILY WHEN EVER CONCRETE PRODUCTION
8 8
4280 1000 1000 173 PAVEMENT QUALITY CONCRETE (PQC) WATER ABSORPTION & SPECIFIC GRAVITY DAILY WHEN EVER CONCRETE PRODUCTION
0 0
4280 1000 1000 174 PAVEMENT QUALITY CONCRETE (PQC) AGGREGATE IMPACT VALUE (AIV) ONE PER SOURCE & MONTHLY SUBSEQUENTLY
4 4
4280 1000 1000 175 PAVEMENT QUALITY CONCRETE (PQC) COMBINED FLAKINESS & ELONGATION INDEX ONE PER SOURCE & MONTHLY SUBSEQUENTLY
5 5
4280 1000 1000 176 PAVEMENT QUALITY CONCRETE (PQC) COMPRESSIVE STRENGTH 2 CUBES PER 150 CUM OR PART THREOF OR MINIMUIM 6 CUBES PER DAY'S WORK
393 393
4280 1000 1000 177 PAVEMENT QUALITY CONCRETE (PQC) FLEXURAL STRENGTH 2 BEAMS PER 150 CUM OR PART THREOF OR MINIMUIM 6 BEAMS PER DAY'S WORK
393 393
4280 1000 1000 178 PAVEMENT QUALITY CONCRETE (PQC) CORE STRENGTH OF HARDENED CONCRETE AS PER REQUIREMENT OF THE ENGINEER
18 18
4280 1000 1000 179 PAVEMENT QUALITY CONCRETE (PQC) WORKABILITY OF FRESH CONCRETE (SLUMP TEST) EACH LOAD
310 310
4280 1000 1000 180 PAVEMENT QUALITY CONCRETE (PQC) DELETERIOUS CONTENT - (THIRD PARTY TEST) ONE PER SOURCE
0 0
4280 1000 1000 181 PAVEMENT QUALITY CONCRETE (PQC) SAND EQUIVALENT VALUE - (THIRD PARTY TEST) ONE TEST PER SOURCE AND WHENEVER CHANGE IN THE QUALITY OF AGGREGATE
0 0
4280 1000 1000 182 PAVEMENT QUALITY CONCRETE (PQC) SOUNDNESS TEST - (THIRD PARTY TEST) INITIALLY FOR SOURCE APPROVAL & MONTHLY SUBSEQUENTLY
0 0
4280 1000 1000 183 PAVEMENT QUALITY CONCRETE (PQC) ALKALI-AGGREGATE REACTIVITY - (THIRD PARTY TEST) INITIALLY FOR SOURCE APPROVAL & MONTHLY SUBSEQUENTLY
0 0
4280 1000 1000 184 PAVEMENT QUALITY CONCRETE (PQC) PQC MATERIAL - (THIRD PARTY TEST) AS PER REQUIREMENT
0 0
4280 1000 1000 185 REINFORCEMENT STEEL - 6 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 186 REINFORCEMENT STEEL - 6 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 187 REINFORCEMENT STEEL - 6 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 188 REINFORCEMENT STEEL - 8 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 189 REINFORCEMENT STEEL - 8 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 190 REINFORCEMENT STEEL - 8 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 191 REINFORCEMENT STEEL - 10 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 192 REINFORCEMENT STEEL - 10 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 193 REINFORCEMENT STEEL - 10 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 194 REINFORCEMENT STEEL - 12 MM UNIT WEIGHT PER METRE EACH LOT
3 3
4280 1000 1000 195 REINFORCEMENT STEEL - 12 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 196 REINFORCEMENT STEEL - 12 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 197 REINFORCEMENT STEEL - 16 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 198 REINFORCEMENT STEEL - 16 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 199 REINFORCEMENT STEEL - 16 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 200 REINFORCEMENT STEEL - 20 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 201 REINFORCEMENT STEEL - 20 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 202 REINFORCEMENT STEEL - 20 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 203 REINFORCEMENT STEEL - 25 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 204 REINFORCEMENT STEEL - 25 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 205 REINFORCEMENT STEEL - 25 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 206 REINFORCEMENT STEEL - 28 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 207 REINFORCEMENT STEEL - 28 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 208 REINFORCEMENT STEEL - 28 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 209 REINFORCEMENT STEEL - 32 MM UNIT WEIGHT PER METRE EACH LOT
4280 1000 1000 210 REINFORCEMENT STEEL - 32 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 211 REINFORCEMENT STEEL - 32 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 212 REINFORCEMENT STEEL - 36 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 213 REINFORCEMENT STEEL - 36 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 214 REINFORCEMENT STEEL - 36 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 215 REINFORCEMENT STEEL - 40 MM UNIT WEIGHT PER METRE EACH LOT
0 0
4280 1000 1000 216 REINFORCEMENT STEEL - 40 MM PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 217 REINFORCEMENT STEEL - 40 MM CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 218 COUPLER PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 219 COUPLER CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 220 STRUCTURAL STEEL PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 221 STRUCTURAL STEEL CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 222 HOT APPLIED THERMOPLASTIC ROAD MARKITHERMOPLAST MATERIAL - (THIRD PARTY TEST) ONE PER SOURCE
0 0
4280 1000 1000 223 GROUTING COMPRESSIVE STRENGTH AS REQUIRED
0 0
4280 1000 1000 224 HUME PIPES PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 225 DOWEL BARS PHYSICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 226 DOWEL BARS CHEMICAL TEST - (THIRD PARTY TEST) EACH LOT
0 0
4280 1000 1000 227 CURING COMPUND THIRD PARTY TEST EACH SOURCE
0 0
4280 1000 1000 228 INHIBITOR SOLUTION THIRD PARTY TEST EACH SOURCE
0 0
4280 1000 1000 229 HT STRANDS THIRD PARTY TEST EACH LOT
0 0
4280 1000 1000 230 ELASTOMERIC BEARING THIRD PARTY TEST EACH LOT
0 0
4280 1000 1000 231 PTFE POT BEARING THIRD PARTY TEST EACH LOT
0 0
4280 1000 1000 232 HDPE SHEATHING DUCT (RAW MATERIAL PRO
THIRD PARTY TEST EACH LOT
0 0
4280 1000 1000 233 STRIP SEAL EXPANSION JOINT THIRD PARTY TEST EACH LOT
0 0
4280 1000 1000 234 EPOXY BONDING AGENT THIRD PARTY TEST EACH LOT 0 0