Professional Documents
Culture Documents
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
REGULATIONS : ATEX
G.Martina
A H.Tuytelaars M. KRAUS RELEASED
NOTE : Note. 11-01-2011
H.Tuytelaars
B M. Kleijn M. Kleijn As-Built
14-09-2011
G.Martina
C 8974 M. Kleijn M. Kleijn As-Built
Total number of pages : 269 16-09-2011
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = GEN + - 1
0 1 2 3 4 5 6 7 8 9
=PWRP Powerpack +ECP2 ECP2 = CAB 2X115V 125A SM IFM F&G ATX 8501036545/1
+EJB9 EJB 220x220x120 SS ATX ASSY PWRP SUP. - ..../1 EJB9 PWRP shore connection
+EJB10 EJB 500x160x100 SS ATX ASSY INSIDE 8501036547/1 EJB10 Cabin RIG SIGNALS
+EJB11 EJB 500x160x100 SS ATX ASSY OUTSIDE 8501036547/1 EJB11 Cabin RIG SIGNALS
+EJB14 EJB 110x75x55 POLY ATX ASSY A1070273 EJB14 = Door switch
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Higher level assignment- / location designation overview = GEN + - 2
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.a
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.b
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.a
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.a PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.c
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.b
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.b PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.d
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.c
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.c PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.e
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.d
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.d PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.f
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.e
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.e PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.g
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.f
0 1 2 3 4 5 6 7 8 9
Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.f PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE =CAB/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Page overview = GEN + - 3.g
0 1 2 3 4 5 6 7 8 9
Energieweg 26, 2964 LE, Groot-Ammers, The Netherlands, (t) +31 184 608 700, (f) +31 184 608 790
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
=GEN/3.g PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 20
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 14.Jan.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + - 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
+ECP2
X21 X22 X21 X21 X21 X22 X22 X22 X22 X22 X22 X22 X28 X28 X22
W50 W51 W52 W53 W69 W70 W71 W72 W73 W136 W135 W100 W101 W102 W103 W105 W106 W107 W108 W109 W110 W111
RADOX RADOX RADOX Radox RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX RADOX
4x25 mm² 5x2,5 mm² 18x1,5 mm² 5x25 mm² 3x1,5 mm² 5x2,5 mm² 5x2,5 mm² 3x2,5 mm² 7x2,5 mm² 4x10 mm² 5x1,5 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 25x1,5 mm²
+ECP2/100.0 +ECP2/101.2 +ECP2/101.3 +ECP6/100.0 +ECP2/101.0 +ECP2/102.0 +ECP2/102.1 +ECP2/102.2 +ECP2/102.3 +ECP6/103.0 +ECP2/200.7 +ECP2/301.1 +ECP2/301.2 +ECP2/301.4 +ECP2/301.8 +ECP2/302.0 +ECP2/302.1 +ECP2/302.2 +ECP2/302.6 +ECP2/302.7 +ECP2/305.5 +ECP2/101.5
+ECP2/102.8 +ECP2/200.0
+ECP2/300.5 +ECP2/200.6
+EJB14 +ECP2/200.8
X142 X142 X142 +ECP2/300.6
Blue Blue Blue Blue
W104 W137 Marking Marking Marking Marking
Molded-b4 Molded-b4
4x1,5 mm² 4x1,5 mm²
+ECP2/301.8 +ECP2/301.9
M P
G
2+PE
+ECP4/305.1
G +ECP2/301.2
+ECP2/301.8 +ECP2/301.9
P P +ECP2/302.6
-102H3
-101M0 Dashboard Light
Pressurising +ECP2/102.3 -301S1 -301S4 -302B0 -302B2 -302S7
Fan Gas Smoke Low Air Flow
+ECP2/101.0 Emergency
Sensor Sensor Pressure +ECP2/302.2
Stop W99
-102H2 Cabin +ECP2/301.4 +ECP2/302.0
Cabin RADOX
+ECP2/301.1
Cabin light +ECP2/302.7
+ECP2/102.2
8 meter
3x1 mm²
+ECP4/305.1
+ECP6 +ECP4
X61 X61
X42 X44 X42
Cabin Juctionbox ECP4
Cabin Juctionbox ECP6 (Non Zone)
X42 X44
X61 X61 X61 X61 X61 X61 X61 X61 X61 X61 X61
W54 W55 W56 W57 W58 W59 W60 W61 W74 W76 W78 W80 W62 W63 W64 W65 W66 W67 W68 W82 W83 W84 W36 W85 W86 W87 W88 W89 W90 W91 W92 W93 W94 W95 W96 W97 W98
CC600 CC600 CC600 CC600 CC600 CC600 CC600 CC600 RADOX RADOX RADOX RADOX CC600 CC600 CC600 CC600 CC600 CC600 CC600 CC600 CC600 SCB628 Molded-b4 RADOX RADOX Molded-b4 Molded-b4 Molded-b4 Molded-b4 Molded-b4 Molded-b4 Molded-b4 Molded-b4 Molded-b4 Molded-b4 RADOX RADOX
3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² 3x2,5 mm² +ECP6/103.6 3x2,5 mm² 7 meter 7 meter 7 meter 7 meter 7 meter 7 meter 7 meter 7 meter 7 meter 2x2x0,25 mm² 4x1,5 mm² 3x1 mm² 7x1 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 4x1,5 mm² 7x1 mm² 7x1 mm²
+ECP6/100.7 +ECP6/101.1 +ECP6/101.2 +ECP6/101.3 +ECP6/101.4 +ECP6/101.5 +ECP6/101.6 +ECP6/101.7 +ECP6/103.2 +ECP6/103.4 +ECP6/103.6 Thermostat +ECP6/103.8 3x6 mm² 3x6 mm² 3x6 mm² 3x10 mm² 3x6 mm² 3x6 mm² 3x6 mm² 3x2,5 mm² 3x2,5 mm² +ECP4/300.5 +ECP4/200.8 +ECP4/301.5 +ECP4/301.6 +ECP4/302.1 +ECP4/302.2 +ECP4/302.3 +ECP4/302.6 +ECP4/302.7 +ECP4/302.8 +ECP4/303.5 +ECP4/303.7 +ECP4/304.1 +ECP4/304.3 +ECP4/304.5 +ECP4/304.7
-103U6.1 +ECP6/102.2 +ECP6/102.3 +ECP6/102.4 +ECP6/102.5 +ECP6/102.6 +ECP6/102.7 +ECP6/102.8 +ECP2/200.2 +ECP2/200.4 +ECP4/300.5 +ECP4/303.6 +ECP4/303.8 +ECP4/304.4
+ECP2/100.0
PLG1
-SKT1
+ECP2/100.0
WR
RADOX
4x25 mm²
+ECP2/100.0
-100U0
+ECP2/100.0
+ECP2/101.2 +ECP2/300.5
-SKT6 -PLG2
1 THIS DRAWING IS OUR PROPERTY AND IS CONFIDENTIAL. IT IS NOT ALLOWED TO COPY OR TO SHOW TO THIRD PARTIES WITHOUT OUR WRITTEN PERMISSION. 21
Scale 1: 1 Electric Hydraulic HIGHER LEVEL LOCATION PAGE:
TYPE OF UNIT : DATASPLIT C ZONE2 AIRSTART Block Diagram ASSIGNMENT: DESIGNATION:
ENGINEER CABIN EXTRA L ES6931033757
AS-BUILT
+ECP2
CABIN
+EJB10
W112 W113 W114 W115 W116
RADOX RADOX RADOX RADOX RADOX +CPRK /214.3
25x1,5 mm²
+ECP2/201.0
Cabin Juctionbox EJB10 5x2,5 mm²
+ECP2/102.5
12x1,5 mm²
+ECP2/101.7
6 meter
5x2,5 mm²
8 meter
3x2,5 mm²
214U3
+ECP2/200.9 +ECP2/101.7 +ECP2/101.9
X102 X102 X102 X102 X102 X102 +ECP2/300.9
SP
/214.3
WRL
RADOX
+DSHB/210.8 +DSHB/210.0
Kerr Backup OPERATOR 3x1 mm²
+DSHB/210.7
Display PANEL
-210U8 -210U0
-PE1 -PE1
/214.1 PE /214.1 PE
P33 J2 J3 J5 J4
+DSHB/210.9 +DSHB/210.5 +DSHB/210.0 +DSHB/210.2
+CPRK
W233 W208 W206 W207 W209 /60.1
RADOX RADOX RADOX RADOX RADOX Computer Rack W181 W183 W186 W188
/250.6
7x1 mm² 7x1 mm² 6x0,5 mm² 6x0,5 mm² 3.2 meter -60U1 GEXOL GEXOL GEXOL GEXOL
+DSHB/210.9 +DSHB/210.4 +DSHB/210.0 +DSHB/210.2 10x0,5 mm² -250A6 1x8 AWG 1x8 AWG 1x8 AWG 1x8 AWG
/214.1 /214.3 /214.5 /214.6
+DSHB/210.5
250U3
POTENTIAL
MONITOR
/250.2 W180 W182 W184 W187 W189
RADOX GEXOL GEXOL GEXOL GEXOL
3x1 mm² 75 meter 75 meter 75 meter 75 meter
+DSHB/210.7 1x8 AWG 1x8 AWG 1x8 AWG 1x8 AWG
W825 W826 W827 /214.1 /214.3 /214.5 /214.6
RADOX RADOX Coax
8 meter 8 meter 8 meter
5x1,5 mm² 3x1,5 mm² 1x0,5 mm²
/250.2 /250.4 /250.6
/60.1
20 THIS DRAWING IS OUR PROPERTY AND IS CONFIDENTIAL. IT IS NOT ALLOWED TO COPY OR TO SHOW TO THIRD PARTIES WITHOUT OUR WRITTEN PERMISSION. 31
Scale 1: 1 Electric Hydraulic HIGHER LEVEL LOCATION PAGE:
TYPE OF UNIT : DATASPLIT C ZONE2 AIRSTART Block Diagram ASSIGNMENT: DESIGNATION:
ENGINEER CABIN EXTRA L ES6931033757
AS-BUILT
CONNECTORS
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
21 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 32
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors = CAB + - 31
0 1 2 3 4 5 6 7 8 9
+ -
TERMINAL PROXIMITY SWITCH VALVE
M
SAFETY FUSE MOTOR
1~
CIRCUITBREAKER LIGHT
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
31 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 60
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 14.Jan.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electric symbol overview = CAB + - 32
0 1 2 3 4 5 6 7 8 9
+CPRK
-60U1
/21.4
COMPUTER RACK
W118 1 2 3 4 5 6 ye/gn
/21.4
/21.4
/60.1
A1101335
=CAB 1 2 3 4 5 6 7 8 9 ... 19
SKT71
Connections to:
WNCH page 60
Slipring
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
32 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 61
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Slipring = CAB + - 60
0 1 2 3 4 5 6 7 8 9
+EJB10
10xM25 & 6xM20
A1060082
X102 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
10
11
12
10
11
12
W40 1 2 3 4 5 W41 1 2 3 4 5 6 W42 1 2 3 4 5 6 7 8 W43 1 2 3 4 5 W44 1 2 3 4 5 6 7 8 9 10 11 12 W45 -
7
9
/21.4 /21.4 /21.5 /21.5 /21.6 /21.6
X112 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
+EJB11
10xM25 & 6xM20
A1060082
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
60 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 214
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 12.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connection Layout EJB10 & 11 = CAB + - 61
0 1 2 3 4 5 6 7 8 9
+CPRK
Computerrack
/21.12
214U3
SP
W119 1 2 GN/YE
/21.12
/21.12
/214.3
A1058159
A1102238
=CAB
A B C
SKT59
+BLKH/200.2
+BLKH /21.12
+BLKH/200.2
SP/DLL
SKT59a A B C
PLG59 B C PLG60 B C
=CAB A =CAB A
A1058172 A1058172
A1082717 A1082717
/214.3
/214.6
PE1 PE1
PE PE PE
-SP
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
61 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 250
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Reels = CAB + - 214
0 1 2 3 4 5 6 7 8 9
+CPRK
Computerrack
Cabin
-250U3
=CAB+ Alarm 12VDC POTENTIAL
MONITOR
/250.2
- +
/21.9
A1082718 /21.9
A1068683 A1082717
Wellhead A1068682
Monitor A B C D E Green Light A B C
SKT62 SKT61
+BLKH/200.0
+BLKH/200.2
+BLKH/200.0
Wellhead +BLKH/200.2
Monitor Green Light
SKT62a A B C D E SKT61a A B C
-250A6
Connections to: Connections to: Antenna
A1041099
WNCH+ECP20 WNCH+ECP20 /21.10
page 250 page 250 Note: Coax cable maximum lenght is 18 ft
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
214 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : WHM System = CAB + - 250
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W825
CABLE NAME
CABLE NAME
=CAB+
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
3 =CAB+-SKT62 C =CAB/250.2
4 =CAB+-SKT62 D =CAB/250.2
5 =CAB+-SKT62 E =CAB/250.3
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
250 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1400
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+# = CAB + - 1100
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP4-X42 =CAB+DSHB-200S8
=CAB-W36 Molded-b4 4x1,5 mm² A1040277
TERMINAL STRIP X42 JUNCTION BOX ECP4 Windscreen Wiper
=CAB+ECP4-X44
=CAB+EJB10-X102 =CAB+EJB11-X112
=CAB-W40 RADOX 5x1,5 mm² 6 meter A1049158
TERMINAL STRIP X102 JUNCTION BOX EJB10 TERMINAL STRIP X112 JUNCTION BOX EJB11
=CAB+EJB10-X102 =CAB+EJB11-X112
=CAB-W41 RADOX 12x1,5 mm² 6 meter A1064044
TERMINAL STRIP X102 JUNCTION BOX EJB10 TERMINAL STRIP X112 JUNCTION BOX EJB11
=CAB+EJB10-X102 =CAB+EJB11-X112
=CAB-W42 RADOX 12x1,5 mm² 6 meter A1064044
TERMINAL STRIP X102 JUNCTION BOX EJB10 TERMINAL STRIP X112 JUNCTION BOX EJB11
=CAB+EJB10-X102 =CAB+EJB11-X112
=CAB-W43 RADOX 5x1,5 mm² 6 meter A1049158
TERMINAL STRIP X102 JUNCTION BOX EJB10 TERMINAL STRIP X112 JUNCTION BOX EJB11
=CAB+EJB10-X102 =CAB+EJB11-X112
=CAB-W44 RADOX 12x1,5 mm² 6 meter A1064044
TERMINAL STRIP X102 JUNCTION BOX EJB10 TERMINAL STRIP X112 JUNCTION BOX EJB11
=CAB+EJB10-X102
=CAB-W45 COAX 1x1,5 mm² 6 meter A0018386
TERMINAL STRIP X102 JUNCTION BOX EJB10
=CAB+EJB11-X112
=CAB+ECP2-X21 =CAB+-PLG1
=CAB-W50 RADOX 4x25 mm² A1055972
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) PLUG
=CAB+ECP2-X22 =CAB+-SKT6
=CAB-W51 RADOX 5x2,5 mm² A1055970
Pressurising Fan Pressurising Fan
=CAB+-PLG2 =CAB+ECP2-X22
=CAB-W52 RADOX 18x1,5 mm² A1049120
0VDC GROUND ANALOGUE OUTPUTS TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
=CAB+ECP2-X21
Dashboard Light
=CAB+ECP2-X21 =CAB+ECP6-X61
=CAB-W53 Radox 5x25 mm² A1055972
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-X61 =CAB+-100X7
=CAB-W54 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-X61 =CAB+-101X1
=CAB-W55 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 (101F1)
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W36 < = > =CAB#-W55 = CAB + - 1400
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP6-X61 =CAB+-101X2
=CAB-W56 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 (101F1)
=CAB+ECP6-X61 =CAB+-101X3
=CAB-W57 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 (101F1)
=CAB+ECP6-X61 =CAB+-101X4
=CAB-W58 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 (101F4)
=CAB+ECP6-X61 =CAB+-101X5
=CAB-W59 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 (101F4)
=CAB+ECP6-X61 =CAB+-101X6
=CAB-W60 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 (101F4)
=CAB+ECP6-X61 =CAB+-101X7
=CAB-W61 CC600 3x2,5 mm² A1037830
TERMINAL STRIP X61 JUNCTION BOX ECP6 Depth Panel (101F4)
=CAB+ECP6-X61 =CAB+CPRK-102U2
=CAB-W62 CC600 3x6 mm² 7 meter A1040099
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F2
=CAB+ECP6-X61 =CAB+CPRK-102U3
=CAB-W63 CC600 3x6 mm² 7 meter A1040099
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F3
=CAB+ECP6-X61 =CAB+CPRK-102U4
=CAB-W64 CC600 3x6 mm² 7 meter A1040099
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F4
=CAB+ECP6-X61 =CAB+CPRK-102U5
=CAB-W65 CC600 3x10 mm² 7 meter A1038348
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F5
=CAB+ECP6-X61 =CAB+CPRK-102U6
=CAB-W66 CC600 3x6 mm² 7 meter A1040099
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F6
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W56 < = > =CAB#-W66 = CAB + - 1401
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP6-X61 =CAB+CPRK-102U7
=CAB-W67 CC600 3x6 mm² 7 meter A1040099
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F7
=CAB+ECP6-X61 =CAB+CPRK-102U8
=CAB-W68 CC600 3x6 mm² 7 meter A1040099
TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+ECP6-102F8
=CAB+ECP2-X21 =CAB+-101M0
=CAB-W69 RADOX 3x1,5 mm² A1082865
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) Pressurising Fan
=CAB+ECP2-X21 =CAB+-102S0
=CAB-W70 RADOX 5x2,5 mm² A1055970
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) Cabin light Switch 1
=CAB+ECP2-X21 =CAB+-102S1
=CAB-W71 RADOX 5x2,5 mm² A1055970
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) Cabin light Switch 2
=CAB+ECP2-X21 =CAB+-102H2
=CAB-W72 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) Cabin light
=CAB+ECP2-X21 =CAB+-102H3
=CAB-W73 RADOX 7x2,5 mm² A1073579
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) Dashboard Light
=CAB+ECP6-X61 =CAB+-103U2
=CAB-W74 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X61 JUNCTION BOX ECP6 Cabin airco 1
=CAB+-103U2 =CAB+-103U4
=CAB-W75 RADOX 5x2,5 mm² A1055970
Cabin airco 1 Cabin airco 2
=CAB+ECP6-X61 =CAB+-103U4
=CAB-W76 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X61 JUNCTION BOX ECP6 Cabin airco 2
=CAB+ECP6-X61 =CAB+-103U6
=CAB-W78 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X61 JUNCTION BOX ECP6 Cabin airco 3
=CAB+-103U6.1 =CAB+-103U6
=CAB-W78.1 RADOX 5x2,5 mm² A1055970
Thermostat Cabin airco 3
=CAB+-103U6 =CAB+-103U8
=CAB-W79 RADOX 5x2,5 mm² A1055970
Cabin airco 3 Cabin airco 4
=CAB+ECP6-X61 =CAB+-103U8
=CAB-W80 RADOX 3x2,5 mm² A1049117
TERMINAL STRIP X61 JUNCTION BOX ECP6 Cabin airco 4
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W67 < = > =CAB#-W80 = CAB + - 1402
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP2-X22 =CAB+CPRK-200U2
=CAB-W82 CC600 3x2,5 mm² 7 meter A1037830
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) 12VDC Supply Shooting Panel
=CAB+ECP2-X26
=CAB+ECP2-X22 =CAB+CPRK-200U4
=CAB-W83 CC600 3x2,5 mm² 7 meter A1037830
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) 12VDC Supply WHM
=CAB+ECP2-X26
=CAB+ECP4-X42 =CAB+DSHB-PLGA
=CAB-W84 SCB628 2x2x0,25 mm² A1037839
0VDC GROUND ANALOGUE OUTPUTS 0VDC GROUND ANALOGUE OUTPUTS
=CAB+ECP4-X44 =CAB+DSHB-300P4
=CAB+ECP4-X42 =CAB+DSHB-301R5
=CAB-W85 RADOX 3x1 mm² A1049118
Line Tension Line Tension
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-301J6
=CAB-W86 RADOX 7x1 mm² A1049155
Winch Speed Winch Speed
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-302S1
=CAB-W87 Molded-b4 4x1,5 mm² A1040277
Autospooling Off / On Autospooling Off / On
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-302S2
=CAB-W88 Molded-b4 4x1,5 mm² A1040277
Wirespray Off / On Wirespray Off / On
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-302S3
=CAB-W89 Molded-b4 4x1,5 mm² A1040277
Horn Horn
=CAB+ECP4-X44
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W82 < = > =CAB#-W89 = CAB + - 1403
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP4-X42 =CAB+DSHB-302S6
=CAB-W90 Molded-b4 4x1,5 mm² A1040277
Stop Engine Stop Engine
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-302S7
=CAB-W91 Molded-b4 4x1,5 mm² A1040277
Emergency Stop Dashboard Emergency Stop Dashboard
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-302S8
=CAB-W92 Molded-b4 4x1,5 mm² A1040277
Winch Stop
=CAB+ECP4-X44
=CAB+ECP4-200K3
Winch Stop
=CAB+ECP4-X42 =CAB+DSHB-303S4
=CAB-W93 Molded-b4 4x1,5 mm² A1040277
Start Generator
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-303S7
=CAB-W94 Molded-b4 4x1,5 mm² A1040277
Stop Generator SPEED Low / Medium / High
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-304S1
=CAB-W95 Molded-b4 4x1,5 mm² A1040277
Brake Control Brake Control
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-304S2
=CAB-W96 Molded-b4 4x1,5 mm² A1040277
Throttle Up Throttle Up
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-304J5
=CAB-W97 RADOX 7x1 mm² A1049155
Levelwind Levelwind
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W90 < = > =CAB#-W97 = CAB + - 1404
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+DSHB-304J5
=CAB-W98 RADOX 7x1 mm² A1049155
Levelwind Down Levelwind
=CAB+ECP4-X44
=CAB+ECP4-X42 =CAB+-305Z1
=CAB-W99 RADOX 3x1 mm² 8 meter A1049118
TERMINAL STRIP X42 JUNCTION BOX ECP4 Horn
=CAB+ECP2-X22 =CAB+-301S1
=CAB-W100 RADOX 3x1 mm² A1049118
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) Gas Sensor Cabin
=CAB+ECP2-X22 =CAB+-301S2
=CAB-W101 RADOX 3x1 mm² A1049118
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) Gas Sensor Air Inlet
=CAB+ECP2-X22 =CAB+-301S4
=CAB-W102 RADOX 3x1 mm² A1049118
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) Smoke Sensor
=CAB+ECP2-X28
=CAB+ECP2-X22 =CAB+EJB14-X142
=CAB-W103 RADOX 3x1 mm² A1049118
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) TERMINAL STRIP X142 JUNCTION BOX EJB14
=CAB+EJB14-X142 =CAB+-301S8
=CAB-W104 Molded-b4 4x1,5 mm² A1040277
TERMINAL STRIP X142 JUNCTION BOX EJB14 Door Switch Left
=CAB+ECP2-X22 =CAB+-302B0
=CAB-W105 RADOX 3x1 mm² A1049118
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) Low Pressure
=CAB+ECP2-X28
Low Pressure
=CAB+ECP2-X28 =CAB+-302B1
=CAB-W106 RADOX 3x1 mm² A1049118
TERMINAL STRIP X28 CONTROL PANEL JB2 (IS) Low Pressure
=CAB+ECP2-X28 =CAB+-302B2
=CAB-W107 RADOX 3x1 mm² A1049118
TERMINAL STRIP X28 CONTROL PANEL JB2 (IS) Air Flow
=CAB+ECP2-X22 =CAB+-302S6
=CAB-W108 RADOX 3x1 mm² A1049118
PRESSURIZING FAN OVERHEATED Manual Call Point
=CAB+ECP2-X28
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W97 < = > =CAB#-W108 = CAB + - 1405
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+ECP2-X22 =CAB+-302S7
=CAB-W109 RADOX 3x1 mm² A1049118
Manual Call Alarm Emergency Stop Cabin
=CAB+ECP2-X28
=CAB+ECP2-X28 =CAB+-305Z5
=CAB-W110 RADOX 3x1 mm² A1049118
TERMINAL STRIP X28 CONTROL PANEL JB2 (IS) SOUNDER
=CAB+ECP2-X22 =CAB+ECP4-X42
=CAB-W111 RADOX 25x1,5 mm² A1094360
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) TERMINAL STRIP X42 JUNCTION BOX ECP4
=CAB+ECP2-X26 =CAB+ECP4-X44
TERMINAL STRIP X26 CONTROL PANEL JB2 TERMINAL STRIP X44 JUNCTION BOX ECP4
=CAB+ECP2-X22 =CAB+EJB11-X112
=CAB-W112 RADOX 25x1,5 mm² A1094360
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) TERMINAL STRIP X112 JUNCTION BOX EJB11
=CAB+-SKT4 =CAB+ECP2-X21
=CAB-W113 RADOX 5x2,5 mm² A1055970
Dashboard Light TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC)
=CAB+-SKT3 =CAB+ECP2-X22
=CAB-W114 RADOX 12x1,5 mm² A1064044
CANBUS TO DASHBOARD TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
=CAB+ECP2-X22 =CAB+-101A8
=CAB-W115 RADOX 5x2,5 mm² 6 meter A1055970
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) Intercom
=CAB+-SKT57 =CAB+ECP2-X22
=CAB-W116 RADOX 3x2,5 mm² 8 meter A1049117
Intercom 1 TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
=CAB+-SKT71 =CAB+CPRK-60U1
=CAB-W118 SABIX-SLPRNG 7x1 mm² A1111587
Connector Bulkhead SKT52 Loadpin
=CAB+-SKT59 =CAB+CPRK-214U3-SP
=CAB-W119 CC600 3x2,5 mm² A1037830
Connector Bulkhead SKT57 SP SP/DLL
=CAB+ECP4-X42 =CAB+DSHB-J1
=CAB-W120 RADOX 2x1,5 mm² A1064704
TERMINAL STRIP X42 JUNCTION BOX ECP4
=CAB+ECP2-X22 =CAB+-104M2
=CAB-W135 RADOX 5x1,5 mm² A1049158
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC) SCREEN WIPER
=CAB+ECP2-X21 =CAB+ECP6-X61
=CAB-W136 RADOX 4x10 mm² A1055971
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC) TERMINAL STRIP X61 JUNCTION BOX ECP6
=CAB+EJB14-X142 =CAB+-301S9
=CAB-W137 Molded-b4 4x1,5 mm² A1040277
TERMINAL STRIP X142 JUNCTION BOX EJB14 Door Switch Right
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W109 < = > =CAB#-W137 = CAB + - 1406
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+-210W7 =CAB+-210Z7
=CAB-W180 RADOX 3x1 mm² A1049118
Intercom Speaker
=CAB+-214W1 =CAB+-PE1
=CAB-W181 GEXOL 1x8 AWG A1024932
reel empty
=CAB+-214U0-PE =CAB+-214W1
=CAB-W182 GEXOL 1x8 AWG 75 meter A1024932
reel empty
=CAB+-PLG59 =CAB+-214W3
=CAB-W183 GEXOL 1x8 AWG A1024932
Connector Bulkhead SKT52 SP reel empty
=CAB+-214U3.1 =CAB+-214W3
=CAB-W184 GEXOL 1x8 AWG 75 meter A1024932
SP/DLL reel empty
=CAB+-214U3.1-SP
=CAB+-214W5 =CAB+-PE1
=CAB-W186 GEXOL 1x8 AWG A1024932
reel empty
=CAB+-214U5-PE =CAB+-214W5
=CAB-W187 GEXOL 1x8 AWG 75 meter A1024932
reel empty
=CAB+-PLG59 =CAB+-214W6
=CAB-W188 GEXOL 1x8 AWG A1024932
SP/DLL reel empty
=CAB+-PLG60
=CAB+-214U6 =CAB+-214W6
=CAB-W189 GEXOL 1x8 AWG 75 meter A1024932
SP/DLL reel empty
=CAB+-214U6-PE
=CAB+-SKT51 =CAB+DSHB-J3
=CAB-W206 RADOX 6x0,5 mm² A1064046
Encoder 1
=CAB+DSHB-J5
Encoder 1
=CAB+-SKT52 =CAB+DSHB-J5
=CAB-W207 RADOX 6x0,5 mm² A1064046
Encoder 2 Encoder 1
=CAB+DSHB-J4
Loadpin
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W180 < = > =CAB#-W207 = CAB + - 1407
0 1 2 3 4 5 6 7 8 9
Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=CAB+-SKT50 =CAB+DSHB-J2
=CAB-W208 RADOX 7x1 mm² A1049155
Loadpin Loadpin
=CAB+DSHB-J9
Encoder 2
=CAB+-SKT56 =CAB+DSHB-J4
=CAB-W209 RADOX 10x0,5 mm² 3.2 meter A1064047
MMD Loadpin
=CAB+DSHB-J2
Loadpin
=CAB+ECP4-X42 =CAB+DSHB-210U8
=CAB-W232 Molded-a3 3x1,5 mm² A1040277
TERMINAL STRIP X42 JUNCTION BOX ECP4 Kerr Backup Display
=CAB+-SKT53 =CAB+DSHB-P33
=CAB-W233 RADOX 7x1 mm² A1049155
Encoder 3 Encoder 3
=CAB+-SKT62 =CAB+CPRK-250U3
=CAB-W825 RADOX 5x1,5 mm² 8 meter A1049158
Wellhead Monitor POTENTIAL MONITOR
=CAB+
=CAB+-SKT61 =CAB+CPRK-250U3
=CAB-W826 RADOX 3x1,5 mm² 8 meter A1082865
Green Light POTENTIAL MONITOR
=CAB+CPRK-250U3 =CAB+-250A6
=CAB-W827 Coax 1x0,5 mm² 8 meter A0018386
POTENTIAL MONITOR Antenna
=CAB+-100U0 =CAB+-SKT1
=CAB-WR RADOX 4x25 mm² A1055972
=CAB+-PLG57 =CAB+-210W7
=CAB-WRL RADOX 3x1 mm² A1049118
Intercom 1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cable overview : =CAB#-W208 < = > =CAB#-WRL = CAB + - 1408
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1408 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + - 1500
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1502
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + - 1501
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + - 1502
0 1 2 3 4 5 6 7 8 9
Apollo II 1G Ex ia IIC T4
=CAB+-301S4 Smoke Detector & Base A1062158
C03345 Baseefa06ATEX0007X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1502 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + - 2500
0 1 2 3 4 5 6 7 8 9
Ex II 3 (1)G Ex de nA nC nL (ia) II B T
=CAB+-ECP2 ECP2 CAB 2X115V 125A SM IFM F&G ATX > 8501036545-1
8501036545-1 A
Amphenol Ex II 3G Ex nA T3
=CAB+-PLG2 Mil PLUG 23P SIZE 32 STRAIGHT ADG ASSY ATX A1068665
Ex Assembly ADG Serie ATEX 2240X A
Amphenol Ex II 3G Ex nA T3
=CAB+-SKT3 Mil SOCKET 23P SIZE 32 WALL F.ADG ASSY ATX A1068666
ADG-00A-32-6S-621 [Ex nA] ATEX 2240X A
Amphenol Ex II 3G Ex nA T3
=CAB+-SKT4 Mil SOCKET 8P SIZE 32 WALL F.ADG ASSY ATX A1089486
Ex Assembly ADG Serie EPSILON 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+-SKT50 EX Straight Socket, 10S, Shell size 12 A1068686
PT06SE12-10S-SR (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. II 3 G Ex nA II T3
=CAB+-SKT52 EX Straight Socket, 8S, Shell size 12 A1068685
PT06SE12-8S-SR (Ex nA) EPSILON 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+-SKT56 EX Straight Socket, 10S, Shell size 12 A1068686
PT06SE12-10S-SR (Ex nA) Epsilon 07 ATEX 2240X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2502
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + - 2501
0 1 2 3 4 5 6 7 8 9
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+-SKT61 EX Straight Socket, 3S, Shell size 12 A1068682
PT06SE12-3S-SR (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+-SKT62 EX Straight Socket, 5S, Shell size 14 A1068683
PT06SE14-5S-SR (Ex nA) Epsilon 07 ATEX 2240X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP2/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + - 2502
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+/2502 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 30
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + ECP2 - 1
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 31
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminal Strips & Connectors = CAB + ECP2 - 30
0 1 2 3 4 5 6 7 8 9
CONNECTORS
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
30 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 40
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors = CAB + ECP2 - 31
0 1 2 3 4 5 6 7 8 9
EEx d EEx d
EEx e EEx e
EEx e EEx e
EEx d EEx d
EEx e EEx e
EEx e EEx e
EEx d EEx d
EEx e EEx e
EEx e EEx e
EEx d EEx d
EEx e EEx e
EEx e EEx e
EEx d EEx d
EEx e EEx e
EEx e EEx e
EEx d F 26 27 28 29 30 31 32 EEx d
EEx e EEx e
SPARE sp sp sp sp sp sp sp
EEx e EEx e
EEx d G 6 7 EEx d
EEx e EEx e
SPARE sp sp
EEx e EEx e
EEx d H 3 4 5 6 PE EEx d
EEx e EEx e
SPARE sp sp sp sp sp
EEx e EEx e
EEx d EEx d
EEx e EEx e
EEx e EEx e
EEx d EEx d
EEx e EEx e
EEx e EEx e
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
31 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Line Bushings = CAB + ECP2 - 40
0 1 2 3 4 5 6 7 8 9
110VAC 60Hz
+-ECP2
8501036545-1
110VAC 60Hz
1 3 5 7
-100K4
/100.4
2 4 6 8
-100F1A
Under/overvoltage
relay
1A
A0000934
A0020441
A0020442
11
1 2
-100K2
/100.2 12 14
-100F1B
Under/overvoltage A1
relay
-100K2
17-275VAC/DC M
1A
Set 121V-140V A1
A0000934 A2
On = 0,1sec
A0020441
A0020442 Off = 5sec
A1112821 A2
1 2
-100K4 1 3 5 7 1 1 -100F8
125A -100F7 3 3
14 11 /100.3 Main Main
1 3 5 7
12
A1073948 -303K2 Supply
A1042598 /303.2 Supply
2 4 6 8 2 4 2 4 L2
Non Zone L1
16A D-kar 16A D-kar
2 4 6 8 8501040868 8501040868
-100F0
Main Main Power ECP2 EX
L1-SPL / 101.0
Supply
Switch N1-SPL / 101.0
100A L2-SPL / 101.0
8501040862
8501040839 N2-SPL / 101.0
A1048931
8501040869 LED 230V
PE
RD
EEx-d
Voltage
Error
EEx d A 1 2 B 1 2 E PE F 19
-100H3 20 C 1 2 D 1 2 EEx d
EEx e EEx e
PE PE
PE
X21 1 2 3 X21 4 4 5 5 6 6 7 7
EEx e EEx e
+#
W50 1 2 3 4
+/20.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
40 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Main Supply ECP2 = CAB + ECP2 - 100
0 1 2 3 4 5 6 7 8 9
115VAC 60Hz
100.9 / L1-SPL L1-SPL / 102.0
100.9 / N1-SPL N1-SPL / 102.0
115VAC 60Hz
100.9 / L2-SPL L2-SPL / 102.0
100.9 / N2-SPL N2-SPL / 102.0
24VDC-D 0VDC-D
-101Q0 1 3 5 13 21 1 3 -101F2
Pressurising PSU
Fan supply
4,0-6,3A 14 22 101G2
2 4
4A D-kar
/302.5
8501040873
A1085742
I> I> I> 8501040866
L1
2 4 6
1
-101G2 -303K3
24V 20A /303.3
1 3 A1108614 2
-305K4
/305.4 24V
2 4 PE
EEx d H 1 2 G 1 2 3 G 4 5 F 23 24 EEx d
EEx e EEx e
24VDC-E 0VDC-E
PE X1
X2
-101H5
POWER
ON
LED 24V
GN
-101D3 2 4 -101D4 2 4 EEx-d 24VDC-E 24VDC-E
2x 60A 45V 2x 60A 45V A1026947
EEx nA EEx nA
A1066383 1 3 A1066383 1 3 0VDC-E 0VDC-E 0VDC-E
-101F4
-101F2.1 1 2 PP-24VDC -101F5 1 -101F7 1 -101F8 2
24VDC Supply to Dashboard Winch Intercom
Supply Cabin 24VDC 24VDC 2A
20A 25A Supply Supply EEx de
2 1 2 2 1
A1085718 EEx de 20A 20A A1085707
A1079006 A1085719 EEx de EEx de A1079006
A1079006 A1085718 A1085718
24VDC-E
A1 A1079006 A1079006
-101K3
A1029768
PE 24VDC PE IS PE
A2
EEx nC
A1029768
14 11 /300.4
X21 8 9 X22 3 3 4 4 SP X22 1 1 1 1 2 2 2 SP SP X22 5 5 6 6 X22 7 7 8 8 X22 9 10 11 12
12
EEx e EEx e
Cabin Cabin
+/21.11
A1082716
A1068684
L N +/20.4 +/20.4 Intercom 1 A B C D E F
+/21.8
A1100432 /300.5 /300.9 SKT57
M -SKT6 1 2 3 4 SP PLG2 C R P Y K T SKT3 R P
1~
+ECP4/300.0 / +24VDC-ECP2/ECP4
+ECP4/300.0 / 0VDC-ECP2/ECP4
+ECP4/300.1 / PE-ECP2/ECP4
=PWRP+EJB9
-101M0 -101A8
EEx d Intercom
Connections to: Connections to: Connections to: A1085470
120V 0.37kW
A1032701 +/21.8
PWRP+ECP3 PWRP+ECP3 WNCH+ECP5
+/20.3
page 200 page 200 page 300
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 102
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Main 24VDC Supply Control Circuit = CAB + ECP2 - 101
0 1 2 3 4 5 6 7 8 9
115VAC 60Hz
101.9 / L1-SPL L1-SPL / 200.0
101.9 / N1-SPL N1-SPL / 200.0
115VAC 60Hz
101.9 / L2-SPL L2-SPL / 200.0
101.9 / N2-SPL N2-SPL / 200.0
WNL-SPL1 / 200.0
1 N WNL-SPL2 / 200.0
-102F0
Cabin & Winch
Lighting
6A 30mA
C-kar
A1113057
2 N.
EEx d F 15 16 F 17 18 EEx d
EEx e EEx e
-102F0.1 1 -102F5 1
Cabine Winch
Lights Lights
2A 4A
2 2
A1085707 A1085712
A1079006 A1079006
1 3 1 3 1 3
-102S3 -102S5 -102S8
WINCH FLOOD
DASHBOARD
2 4 LIGHT 2 4 LIGHT 2 4
LIGHT
A0021204 A0021204
A0021204
A1026946 A1026946
A1026946
PE PE PE
X21 10 11 12 13 14 15 X21 16 17 18 19 20 X21 21 22 X21 23 24 SP SP SP SP SP SP
EEx e EEx e
11 11 L1 N 2 3 L PE
12 14 12 14
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 200
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Cabin & Winch Lights = CAB + ECP2 - 102
0 1 2 3 4 5 6 7 8 9
115VAC 60Hz
102.9 / L1-SPL L1-ECP2
102.9 / N1-SPL N1-ECP2
115VAC 60Hz
102.9 / L2-SPL L2-ECP2
102.9 / N2-SPL N2-ECP2
-200F0 1 N
PSU
Supply 24VDC-E +12VDC 0VDC-D
200G0
6A 30mA 2 N.
C-kar
102.9 /A1113057
WNL-SPL1
53 83 3 86 87a 87
102.9 / WNL-SPL2 -200K6
L1 -303K3 -303K3 -303K3 24VDC/40A
-200G0 /303.3
54 /303.3
84 /303.3
4 85 A1026872
-200K6
30 /200.6
110/230V
87
12VDC 15A
A1069451
87a 30 /200.7
12V
EEx d F 13 14 21 22 F 8 9 10 11 12 EEx d
EEx e EEx e
-200F5 2
Screen
Wiper
6A
1
EEx de
A1085713
A1079006
24VDC-E
12VDC-E
0VDC-E 0VDC-E
+/21.8
/300.9
SKT3 C E
+ECP4/200.0 / -12VDC
+ECP4/200.1 / -0VDC(12V)
+ECP4/200.1 / -B-EARTH
+ECP4/200.6 / -Wwstch1
+ECP4/200.6 / -GRNL-P
+ECP4/200.4 / -SWCHD-24V
+ECP4/200.4 / -JB4-SP
+ECP4/200.4 / -0VDC
WH BK BK/WH YE GY
+ECP4/200.7 / -Wwstch2
+ECP4/301.1 / Wnch-ctd
SKT20 - - - SKT21 - - -
M
SKT20 + + + SKT21 + + +
-104M2
-200U2 -200U4 SCREEN
12VDC WIPER
12VDC
Supply 24VDC 3A
Supply
Shooting Panel A1103750 Green
WHM
A0019438 +/20.8
A0019437
A0019438 Light
A0019437
A0020257
A0020257
+/20.11
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 201
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 20.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Junctionbox Supply Computer system Control = CAB + ECP2 - 200
0 1 2 3 4 5 6 7 8 9
EEx d EEx d
EEx e EEx e
11 11 11 11 11
12 14 12 14 12 14 12 14 12 14
-EM2
302.7
-EM1
302.7
PE
X22 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 sp 37 38 sp sp sp sp sp
EEx e EEx e
W112 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
+/21.3
X112 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 sp sp sp sp sp PE
+EJB11
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
200 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 300
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 10.Feb.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connection Layout EJB11 = CAB + ECP2 - 201
0 1 2 3 4 5 6 7 8 9
-300U0
EX IFM CR7020
A1066396
A1056781
/300.0 CAN 1 CAN 1 CAN 2 CAN 2
/301.0 VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST
/302.0
/303.0
H L H L
/304.0
/305.0
VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST CAN 1 H CAN 1 L CAN 2 H CAN 2 L
SKTC1 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
/300.0
X24 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
11
-300K4
/300.3 12 14
24V / 300.4
+24Vdc-IFM TEST INPUT :
- NORMAL TO GROUND
- FOR SOFTWARE TO +12/24VDC
-300F0 2 -300F1 2 -300F2 2
IFM IFM IFM
VBB s VBB o CIRCUIT
2A 16A 10A
1 1 1 300.0 / 24V
EEx de EEx de EEx de
A1085712 A1085715 A1085714
A1079006 A1079006 A1079006 PLGA 1 2 4 4 5 6
-300P4 A
EEx nAnL
A1066395 1 2 3 4 5 6
A1061630
24VDC-E
A1061631
7 8 9 10 11 12
A
/300.5
PLGA 7 8
12 14
-101K3
A2 -300K4 /101.3 11
24VDC
EEx nC -300R4
0VDC-E A1 A1029768
120 Ohm
14 11 /300.5 EEx nA
12 A1065791
/31.0
A1043677
A1083957 X22 39 40 X22 41 42 X22 43 44
SKTC2 A B C D E
Ex e Ex e
CANH
+ECP4/300.5
CANL
+ECP4/300.5
Connections to: Connections to:
PWRP+ECP3 WNCH+ECP5
Interface page 300 page 300
Programming
(RS232)
CANBUS CANBUS CANBUS
TO TO TO
POWERPACK DASHBOARD WINCHFRAME
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
201 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 301
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 23.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller EX = CAB + ECP2 - 300
0 1 2 3 4 5 6 7 8 9
EEx d EEx d
EEx e EEx e
IX0.00 IW03 DI / AI IX0.01 IW04 DI / AI IX0.02 IW05 DI / AI IX0.03 IW06 DI / AI IX0.04 IW07 DI / AI IX0.05 IW08 DI / AI IX0.06 IW09 DI / AI IX0.07 IW10 DI / AI
SKTC1 08 27 09 28 10 29 11 30
/300.0
X24 08 27 09 28 10 29 11 30
1 2
-301U4
9167/11-11-00K
A1059897
10 11
+EJB14
EJB 110x75x55
A1070273 X142 1 2 3 4
-301R4
G G 2,2 kOhm
0,25W
L2 out
A1041982
-301S1 -301S2 -301S8 -301S9
Gas Gas -301S4 Door Door
Sensor Sensor Smoke Switch Switch
Cabin Air Inlet Sensor Left Right
A1108467 A1108467 A1062158 A1100133 A1100133
+/20.12 A1112992 +/20.14 +/20.14 +/20.15
+/20.13 GAS AIR Spare Spare
SENSOR EEx ia circuit FLOW
SPARE
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
300 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 302
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 23.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Fire & gas = CAB + ECP2 - 301
0 1 2 3 4 5 6 7 8 9
+24VDC-IFM
21
-101Q0
/101.0
22
EEx d F 1 F 25 EEx d
EEx e EEx e
X24 20
SKTC1 20
QX0.00 DO/AO QX0.01 DO/AO QX0.02 DO/AO QX0.03 DO/AO IX0.13 DI IX0.14 DI IX0.15 DI
INPUT
SKTC1 44 45 46 47 02 21 38
/300.0
X24 44 45 +24VDC-IFM 46 47 02 21 38
+24VDC-IFM
0VDC-E
EM1 / 201.4
EM2 / 201.4
+ - 1 2 4 6
24V -302U0
9170/20-10-11K
10+ 11- A1080113 14+ 15-
+24VDC-IFM +24VDC-IFM
1/2 BK
c nc no c nc no c nc no
P P P 3/4 GY
-302S6 -302S7
Manual Emergency
-302B0 -302B1 -302B2 Call Stop
50 Pa 50 Pa 50 Pa Point Cabin
A1035388 A1035388 Air Flow A1018115 A0021161
+/20.15 +/20.16 A1035388 +/20.17 +/20.17
+/20.16
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
301 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 303
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Fire & gas = CAB + ECP2 - 302
0 1 2 3 4 5 6 7 8 9
GND GND
-303K2 -303K3
A2 24VDC A2 24VDC 9A 53
8501040875 A1082318 -100K4
A1042598 /100.4
A1 A1 54
1 2 /101.7
3 4 /200.5
1 2 /100.5 5 6
3 4 /100.5 13 14
5 6 /100.5 53 54 /200.1
7 8 /100.5 61 62
71 72
83 84 /200.3
EEx d F 2 3 4 5 6 EEx d
EEx e EEx e
X24 19
PA
+24VDC-IFM
303.2 SKTC1 19
QX0.04 DO/AO QX0.05 DO/AO QX0.06 DO/AO QX0.07 DO/AO IX1.05 DI IX1.06 DI IX1.07 DI
INPUT
SKTC1 36 54 17 53 55 18 37
/300.0
X24 36 X24 54 17 53 55 18 37
303.2
PA
-303H1 -303H2
A1 X1 X1
POWER
-303K1 General
Fault ACTIVATED
24VDC
LED 24V LED 24V
EEx nC A2 X2 X2
RD GN
A1029768
EEx-d EEx-d
A1048931 A1026947
-303S7 13 14
NORMAL
PURGE OVRR.
MAINTENANCE
EEx-d
A1101128
X22 50 51
EEx e EEx e
14
12 11 /201.3
SAFETY SWITCH GENERAL POWER SHUTDOWN Spare VOLTAGE NORMAL PURGE MAINTENANCE
(PERFORATION ARMING) FAULT ACTIVATED ZONE 2 ERROR/OK OVERRIDE
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
302 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 304
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Fire & gas = CAB + ECP2 - 303
0 1 2 3 4 5 6 7 8 9
EEx d EEx d
EEx e EEx e
VOLTAGE LOSS
START STOP RESET
SEQUENCE SPARE SPARE SPARE OF
PRESSURIZING PRESSURIZING ALARM
ERROR PRESSURE
SKTC1 39 03 40 22 41 42 43 04
/300.0
X24 39 03 40 22 41 42 43 04
13 21 13 -304K8 A1
24VDC
EEx nC
-304S1 14 -304S2 22 -304S3 14
A1029768 A2
START STOP RESET
PRESSURIZING PRESSURIZING ALARM 14
EEx-d EEx-d EEx-d
GN RD BK 12 11 /201.2
A1059770 A1059770 A1059770
A0021202 A0021202 A0021202
EEx e EEx e
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
303 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 305
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 09.Jun.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Fire & gas = CAB + ECP2 - 304
0 1 2 3 4 5 6 7 8 9
0VDC-D
1 2 /101.0
-305K4 A2 3 4 /101.0
24VDC 17A
A1042092 5 6
A1
EEx d F 7 EEx d
EEx e EEx e
X24 50
SKTC1 50
QX1.00 DO/AO QX1.01 DO QX1.02 DO QX1.04 DO/AO QX1.05 DO QX1.06 DO QX1.07 DO/AO
OUTPUT
SKTC1 48 49 31 51 52 16 35
/300.0
X24 48 49 31 51 52 16 35
11 12
14 14 14 -305U5
MTL 5525
12 11 /201.1 12 11 /201.1 12 11 /201.2 A1094323
2 1
X28 9 10
0VDC-E 0VDC-E 0VDC-E
EEx e EEx e
W110 1 2
+/20.18
-305Z5 x1
24Vdc
A0005267
+/20.18 x2
LOW HIGH SMOKE OVER/ FIRE & GAS Spare Spare Spare
GAS GAS ALARM PRESSURE ALARMS
ALARM ALARM FAN EEx ia circuit
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
304 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 25.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Fire & gas = CAB + ECP2 - 305
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-A
LINE BUSHING A JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
Main Power Supply Shore 2x 110v 60Hz 125A =CAB+ECP2-X21 1 1 =CAB+ECP2-100F0 2 =CAB+ECP2/100.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
305 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-A LINE BUSHING A JUNCTION BOX JB2 = CAB + ECP2 - 1100
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-B
LINE BUSHING B JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
Main Power Supply Shore 2x 110v 60Hz 125A =CAB+ECP2-X21 3 1 =CAB+ECP2-100F0 6 =CAB+ECP2/100.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-B LINE BUSHING B JUNCTION BOX JB2 = CAB + ECP2 - 1101
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-C
LINE BUSHING C JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1103
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-C LINE BUSHING C JUNCTION BOX JB2 = CAB + ECP2 - 1102
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-D
LINE BUSHING D JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1104
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-D LINE BUSHING D JUNCTION BOX JB2 = CAB + ECP2 - 1103
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-E
LINE BUSHING H JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1103 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1105
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-E LINE BUSHING H JUNCTION BOX JB2 = CAB + ECP2 - 1104
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-F
LINE BUSHING F JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= =CAB+ECP2-X22 51 3 =CAB+ECP2/303.0
=CAB+ECP2-SPARE sp 26 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 27 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 28 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 29 =CAB+ECP2/40.1
=CAB+ECP2-SPARE sp 30 =CAB+ECP2/40.1
=CAB+ECP2-SPARE sp 31 =CAB+ECP2/40.1
=CAB+ECP2-SPARE sp 32 =CAB+ECP2/40.1
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1104 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1106
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-F LINE BUSHING F JUNCTION BOX JB2 = CAB + ECP2 - 1105
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-G
LINE BUSHING G JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= =CAB+ECP2-X22 PE 3 =CAB+ECP2/101.2
=CAB+ECP2-SPARE sp 6 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 7 =CAB+ECP2/40.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1105 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1107
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-G LINE BUSHING G JUNCTION BOX JB2 = CAB + ECP2 - 1106
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-H
LINE BUSHING H JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
=CAB+ECP2-SPARE sp 3 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 4 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 5 =CAB+ECP2/40.0
=CAB+ECP2-SPARE sp 6 =CAB+ECP2/40.1
=CAB+ECP2-SPARE sp PE =CAB+ECP2/40.1
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1106 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1108
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-H LINE BUSHING H JUNCTION BOX JB2 = CAB + ECP2 - 1107
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-I
LINE BUSHING I JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1107 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1109
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-I LINE BUSHING I JUNCTION BOX JB2 = CAB + ECP2 - 1108
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-SPARE
TERMINAL STRIP SPARE JUNCTION BOX JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
sp =CAB+ECP2-F 26 =CAB+ECP2/40.0
sp =CAB+ECP2-G 6 =CAB+ECP2/40.0
sp =CAB+ECP2-H 3 =CAB+ECP2/40.0
sp =CAB+ECP2-F 27 =CAB+ECP2/40.0
sp =CAB+ECP2-G 7 =CAB+ECP2/40.0
sp =CAB+ECP2-H 4 =CAB+ECP2/40.0
sp =CAB+ECP2-F 28 =CAB+ECP2/40.0
sp =CAB+ECP2-H 5 =CAB+ECP2/40.0
sp =CAB+ECP2-F 29 =CAB+ECP2/40.1
sp =CAB+ECP2-H 6 =CAB+ECP2/40.1
sp =CAB+ECP2-F 30 =CAB+ECP2/40.1
sp =CAB+ECP2-H PE =CAB+ECP2/40.1
sp =CAB+ECP2-F 31 =CAB+ECP2/40.1
sp =CAB+ECP2-F 32 =CAB+ECP2/40.1
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1108 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1110
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-SPARE TERMINAL STRIP SPARE JUNCTION = CAB + ECP2 - 1109
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W73
=CAB-W72
=CAB-W71
=CAB-W70
=CAB-W69
=CAB-W136
=CAB-W53
=CAB-W50
CABLE NAME
CABLE NAME
=CAB-W71
=CAB+ECP2-X21
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
Main Power Supply Shore 2x 110v 60Hz 125A 1 =CAB+-PLG1 1 1 =CAB+ECP2-A 1 =CAB+ECP2/100.0
= 1 =CAB+ECP6-X61 21 4 =CAB+ECP2/100.5
= 3 =CAB+ECP6-X61 23 6 =CAB+ECP2/100.5
= 4 =CAB+ECP6-X61 24 7 =CAB+ECP2/100.5
= SH =CAB+ECP6-X61 PE PE =CAB+ECP2/100.5
= SH =CAB+ECP6-X61 PE PE =CAB+ECP2/100.6
= 3 =CAB+-101M0 PE PE =CAB+ECP2/101.1
= 1 =CAB+-102H2 14 =CAB+ECP2/102.2
= 7 =CAB+-102H3 PE PE =CAB+ECP2/102.4
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1109 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1111
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X21 TERMINAL STRIP X21 CONTROL = CAB + ECP2 - 1110
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W52
=CAB-W113
CABLE NAME
CABLE NAME
=CAB+ECP2-X21
TERMINAL STRIP X21 CONTROL PANEL JB2 (230VAC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 5 =CAB+-SKT4 F 25 =CAB+ECP2/102.5
= 11 =CAB+-PLG2 E SP =CAB+ECP2/102.9
= 12 =CAB+-PLG2 F SP =CAB+ECP2/102.9
= 13 =CAB+-PLG2 G SP =CAB+ECP2/102.9
= 14 =CAB+-PLG2 H SP =CAB+ECP2/102.9
= 15 =CAB+-PLG2 J SP =CAB+ECP2/102.9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1110 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1112
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X21 TERMINAL STRIP X21 CONTROL = CAB + ECP2 - 1111
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W114
=CAB-W111
=CAB-W51
=CAB-W52
CABLE NAME
CABLE NAME
=CAB+ECP2-X22
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 2 =CAB+-PLG2 R 1 =CAB+ECP2/101.4
= 3 =CAB+-PLG2 R 1 =CAB+ECP2/101.4
= - =CAB+ECP2/101.4
= - =CAB+ECP2/101.4
= - =CAB+ECP2-101H5 X2 =CAB+ECP2/101.4
= - =CAB+ECP2-G 5 =CAB+ECP2/101.4
= - =CAB+ECP2-G 5 =CAB+ECP2/101.4
= - =CAB+ECP2/101.4
= - =CAB+ECP2-X22 2 =CAB+ECP2/101.4
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= 2 =CAB+-SKT6 2 3 =CAB+ECP2/101.2
= 4 =CAB+-SKT6 4 4 =CAB+ECP2/101.2
= PE =CAB+ECP2-101G2 0V =CAB+ECP2/101.2
= PE =CAB+ECP2-G 3 =CAB+ECP2/101.2
= 3 =CAB+ECP4-X42 - 6 =CAB+ECP2/101.6
= 4 =CAB+ECP4-X42 - 6 =CAB+ECP2/101.6
= PE =CAB+ECP2/101.6
= =CAB+ECP2-101F7 1 + =CAB+ECP2/101.7
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1111 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1113
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X22 TERMINAL STRIP X22 CONTROL = CAB + ECP2 - 1112
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W112
=CAB-W135
=CAB-W111
=CAB-W115
=CAB-W114
CABLE NAME
CABLE NAME
=CAB-W116
=CAB-W114
=CAB+ECP2-X22
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
= 3 =CAB+-SKT3 P 8 =CAB+ECP2/101.7
= 4 =CAB+-SKT3 P 8 =CAB+ECP2/101.7
= - =CAB+ECP2/101.8
= 2 =CAB+-101A8 10 =CAB+ECP2/101.8
=CAB+ECP2-200K6 86 - =CAB+ECP2/200.6
2 =CAB+-104M2 BK - =CAB+ECP2/200.7
5 =CAB+-104M2 GY PE =CAB+ECP2/200.7
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1112 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1114
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X22 TERMINAL STRIP X22 CONTROL = CAB + ECP2 - 1113
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W100
=CAB-W114
=CAB-W111
=CAB-W52
=CAB-W112
CABLE NAME
CABLE NAME
=CAB+ECP2-X22
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 17 =CAB+EJB11-X112 65 sp =CAB+ECP2/201.4
= 20 =CAB+EJB11-X112 sp sp =CAB+ECP2/201.5
= 21 =CAB+EJB11-X112 sp sp =CAB+ECP2/201.5
= 22 =CAB+EJB11-X112 sp sp =CAB+ECP2/201.5
= 24 =CAB+EJB11-X112 sp sp =CAB+ECP2/201.5
= 25 =CAB+EJB11-X112 PE PE =CAB+ECP2/201.5
= - =CAB+ECP2/300.2
= - =CAB+ECP2-X24 15 =CAB+ECP2/300.2
= - =CAB+ECP2/300.2
= - =CAB+ECP2-X24 12 =CAB+ECP2/300.2
= - =CAB+ECP2/300.2
= - =CAB+ECP2-X24 33 =CAB+ECP2/300.2
= - =CAB+ECP2/300.2
= - =CAB+ECP2-300K4 12 =CAB+ECP2/300.2
= - =CAB+ECP2/300.2
= - =CAB+ECP2/300.2
= - =CAB+ECP2-300K4 A2 =CAB+ECP2/300.2
= - =CAB+ECP2/300.2
= - =CAB+ECP2-SKTC2 C =CAB+ECP2/300.2
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1113 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1115
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X22 TERMINAL STRIP X22 CONTROL = CAB + ECP2 - 1114
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W109
=CAB-W108
=CAB-W103
=CAB-W101
=CAB-W100
CABLE NAME
CABLE NAME
=CAB+ECP2-X22
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 3 =CAB+EJB14-X142 3 - =CAB+ECP2/301.8
= =CAB+ECP2-302U0 - - =CAB+ECP2/302.1
=CAB+ECP2-F
= 1 =CAB+-302S7 BK + =CAB+ECP2/302.7
= 51 =CAB+ECP2-F 3 =CAB+ECP2/303.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1114 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1116
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X22 TERMINAL STRIP X22 CONTROL = CAB + ECP2 - 1115
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W111
=CAB-W52
CABLE NAME
CABLE NAME
=CAB+ECP2-X22
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
- =CAB+ECP2/200.0
- =CAB+ECP2-X26 2 =CAB+ECP2/200.1
- =CAB+ECP2-F 14 =CAB+ECP2/200.1
=CAB+ECP2-303K3 53 + =CAB+ECP2/200.1
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2-G 4 =CAB+ECP2/101.3
= + =CAB+ECP2-G 4 =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2-101D3 2 =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2/101.3
= + =CAB+ECP2-101D4 2 =CAB+ECP2/101.3
= 16 =CAB+-PLG2 Y SP =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= - =CAB+ECP2/101.5
= 17 =CAB+-PLG2 K SP =CAB+ECP2/101.5
= 18 =CAB+-PLG2 T PE =CAB+ECP2/101.5
= IS =CAB+ECP2/101.5
= =CAB+ECP2-101F5 1 + =CAB+ECP2/101.6
9 =CAB+ECP4-X42 SP SP =CAB+ECP2/200.2
10 =CAB+ECP4-X42 - - =CAB+ECP2/200.2
+ =CAB+ECP2-200F5 1 =CAB+ECP2/200.5
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1115 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1117
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X22 TERMINAL STRIP X22 CONTROL = CAB + ECP2 - 1116
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-X22
TERMINAL STRIP X22 CONTROL PANEL JB2 (24VDC)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1116 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1118
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X22 TERMINAL STRIP X22 CONTROL = CAB + ECP2 - 1117
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-X24
TERMINAL STRIP X24 CONTROL PANEL JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
=CAB+ECP2-X24
=CAB+ECP2-X24
=CAB+ECP2-X22
=CAB+ECP2-X22
=CAB+ECP2-301R5
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1117 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1119
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X24 TERMINAL STRIP X24 CONTROL = CAB + ECP2 - 1118
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP2-X24
TERMINAL STRIP X24 CONTROL PANEL JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
=CAB+ECP2-X24
= 42 =CAB+ECP2-SKTC1 42 =CAB+ECP2/304.6
= 43 =CAB+ECP2-SKTC1 43 =CAB+ECP2/304.7
= 53 =CAB+ECP2-SKTC1 53 =CAB+ECP2/303.4
= + =CAB+ECP2-300K4 14 =CAB+ECP2/300.2
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1118 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1120
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X24 TERMINAL STRIP X24 CONTROL = CAB + ECP2 - 1119
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W83
=CAB-W82
=CAB-W111
CABLE NAME
CABLE NAME
=CAB+ECP2-X26
TERMINAL STRIP X26 CONTROL PANEL JB2
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
+ =CAB+ECP2-F 13 =CAB+ECP2/200.0
25 =CAB+ECP4-X42 PE PE =CAB+ECP2/200.1
=CAB+ECP2-303K3 83 + =CAB+ECP2/200.3
- =CAB+ECP2/200.3
+ =CAB+ECP2/200.0
+ =CAB+ECP2-200F1.1 1 =CAB+ECP2/200.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1119 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1121
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X26 TERMINAL STRIP X26 CONTROL = CAB + ECP2 - 1120
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W110
=CAB-W107
=CAB-W106
=CAB-W105
=CAB-W102
CABLE NAME
CABLE NAME
=CAB+ECP2-X28
TERMINAL STRIP X28 CONTROL PANEL JB2 (IS)
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 2 =CAB+-302B0 no 4 =CAB+ECP2/302.0
= 1 =CAB+-302B1 c 5 =CAB+ECP2/302.1
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1120 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP2#-X28 TERMINAL STRIP X28 CONTROL = CAB + ECP2 - 1121
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1121 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + ECP2 - 1500
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1502
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + ECP2 - 1501
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + ECP2 - 1502
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1502 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + ECP2 - 2500
0 1 2 3 4 5 6 7 8 9
ASEP B.V. II 3 G Ex nA nC II T 3
[EX] Epsilon Certified Safety controller IFM and Connector EX II 3
=CAB+ECP2-300U0 A1066396
G n II T3
[EX] ECOMAT100 CR7020 EX II 3 G n II T3 EPSILON07ATEX2224X A
Stahl Ex II 3G EEx nA II T4
=CAB+ECP2-301U4 Isolating Repeater Loop powered 0/4-20mA EEx nAC II T4 A1059897
9167/11-11-00K 04 ATEX E 082 X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2502
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + ECP2 - 2501
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2503
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + ECP2 - 2502
0 1 2 3 4 5 6 7 8 9
ASEP B.V. II 3G Ex nA II T3
=CAB+ECP2-SKTC2 Mil Receptacle 10P Shell size 12 EEx nA (II 3G Ex nA II T3) A1083957
[EX] 62LC-12E12-10SN(771)-Amphenol EPSILON07ATEX2240X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2502 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP4/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + ECP2 - 2503
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP2/2503 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 30
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + ECP4 - 1
0 1 2 3 4 5 6 7 8 9
=CAB+ECP4-X42 = TERMINAL STRIP X42 JUNCTION BOX ECP4 =CAB+ECP4#-SKTC2 = SKTC2 Interface Programming (RS232)
=CAB+ECP4-X44 = TERMINAL STRIP X44 JUNCTION BOX ECP4
=CAB+ECP4-X46 = TERMINAL STRIP X46 JUNCTION BOX ECP4
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 200
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminal Strips & Connectors = CAB + ECP4 - 30
0 1 2 3 4 5 6 7 8 9
+-ECP4
8501036015-3
0VDC-E 0VDC-E
-200K3 A2 -200K4 A2
24VDC 24VDC
EEx nC EEx nC
A1029768 A1 A1029768 A1
12 14
11
/302.8
12VDC-E 24VDC-E 24VDC-E
24VDC-E
0VDC-E
0VDC-E
-200F0 -200F2 PE
-200F3
Operator Smart Power
Panel Monitor 24Vdc
4A 4A 2A 11
A1085712 A1085712 EEx de
A1079006 A1079006 A1085707
-200K4
A1079006 /200.4 12 14
PE PE 0VDC-E
W36 BK GY
+/20.13
+DSHB
+ECP2/200.1 +DSHB/210.0 +DSHB/210.8 +DSHB/210.8 +ECP2/200.2
-200S8
WIPER BK
-12VDC -0VDC(12V) -OP-0VDC -BP-0VDC -SWCHD-24V -0VDC OFF/ON
+ECP2/200.8 / -GRNL-P
+ECP2/200.6 / -Wwstch2
+ECP2/200.0 +ECP2/200.1 +DSHB/210.0 +DSHB/210.8 +ECP2/200.1 +ECP2/200.2 A1030262
GY
A1016540
+/20.14
+ECP2/200.6 / -Wwstch1
12V Supply Winch Green Green
Supply Operator Shutdown Light Light
Panel By OP By
....
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
30 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 300
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 30.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Junctionbox HES Supply = CAB + ECP4 - 200
0 1 2 3 4 5 6 7 8 9
-300U0
EX IFM CR7020
A1066396
A1056781
/300.0 CAN 1 CAN 1 CAN 2 CAN 2
/301.0 VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST
/302.0
/303.0
H L H L
/304.0
/305.0
VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST CAN 1 H CAN 1 L CAN 2 H CAN 2 L
SKTC1 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
/300.0
X44 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
11
-300K4
/300.3 12 14
24V / 300.4
+24Vdc-IFM TEST INPUT :
- NORMAL TO GROUND
- FOR SOFTWARE TO +12/24VDC
-300F0 -300F1 -300F2
IFM IFM IFM
VBB s VBB o CIRCUIT
2A 16A 10A
EEx de EEx de EEx de 300.0 / 24V
A1085712 A1085715 A1085714
A1079006 A1079006 A1079006 X42 18 19
W84 WH BN
+/20.13
24VDC-E
+DSHB
PLGA 1 2 4 4 5 6
0VDC-E
-300P4 A
EEx nAnL
A1066395 1 2 3 4 5 6
A1061630
A1061631
7 8 9 10 11 12
A 12 14
/300.5
-301K1
PLGA 7 8
A1 -300K4 /301.1
11
24VDC
EEx nC -300R9
0VDC-E A2 A1029768 W84 GN YE
120 Ohm
+/20.13
14 11 /300.5 EEx nA
12 A1065791
PE
/30.6
A1043677
A1083957 X42 16 17
SKTC2 A B C D E
Ex e Ex e
+ECP2/101.6 / +24VDC-ECP2/ECP4
+ECP2/101.6 / 0VDC-ECP2/ECP4
+ECP2/101.6 / PE-ECP2/ECP4
=DSHB-CANH
+ECP2/300.6
=DSHB-CANL
+ECP2/300.6
Interface
Programming
(RS232)
Supply
ECP4
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
200 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 301
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller EX = CAB + ECP4 - 300
0 1 2 3 4 5 6 7 8 9
IX0.00 IW03 DI / AI IX0.01 IW04 DI / AI IX0.02 IW05 DI / AI IX0.03 IW06 DI / AI IX0.04 IW07 DI / AI IX0.05 IW08 DI / AI IX0.06 IW09 DI / AI IX0.07 IW10 DI / AI
SKTC1 08 27 09 28 10 29 11 30
/300.0
X44 08 27 09 28 10 29 11 30
A1
14 11 /300.9
-301K1
12
24VDC A2
EEx nC
A1029768
0VDC-E
24VDC-IFM 24VDC-IFM
0VDC-E 0VDC-E
X42 20
Ex e Ex e
W85 1 2 3 W86 1 2 3 4 5
+/20.14 +/20.14
+DSHB
VS GND SIGN VS GND SIGN
A B
Wnch-ctd
+ECP2/200.9
-301R5 -301J6
EEx nA EEx nA
A1065966 A1065967
+/20.14 +/20.14
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
300 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 302
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Dashboard = CAB + ECP4 - 301
0 1 2 3 4 5 6 7 8 9
Spooling Emergency
Autospooling Wirespray Start Stop Winch
Horn or Stop
Off / On Off / On Engine Engine Stop
Slewing Dashboard
IX0.11 DI
QX0.00 DO/AO QX0.01 DO/AO QX0.02 DO/AO QX0.03 DO/AO IX0.12 DI IX0.13 DI IX0.14 DI IX0.15 DI
SKTC1 44 45 46 47 20 02 21 38
/300.0
X44 44 45 46 47 20 02 21 38
12 14
-200K3
/200.3
11
SP SP SP SP SP SP SP SP SP SP SP SP
Ex e Ex e
+DSHB BN
BU
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
301 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 303
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 30.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Dashboard = CAB + ECP4 - 302
0 1 2 3 4 5 6 7 8 9
INPUT / OUTPUT -300U0 OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT
/300.0
QX0.04 DO/AO QX0.05 DO/AO QX0.06 DO/AO QX0.07 DO/AO IX1.04 DI IX1.05 DI IX1.06 DI IX1.07 DI
SKTC1 36 54 17 53 19 55 18 37
/300.0
X44 36 54 17 53 19 55 18 37
Ex e Ex e
+DSHB
BK BU
GY BN
-303S4 -303S7
Start/Stop SPEED
Generator Low / Medium / High
A1030262 A0021395
A1040349 A0021205
+/20.17 +/20.18
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
302 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 304
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 15.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Dashboard = CAB + ECP4 - 303
0 1 2 3 4 5 6 7 8 9
INPUT / OUTPUT -300U0 INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT
/300.0
SKTC1 39 03 40 22 41 42 43 04
/300.0
X44 39 03 40 22 41 42 43 04
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
303 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 305
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Dashboard = CAB + ECP4 - 304
0 1 2 3 4 5 6 7 8 9
QX1.00 DO/AO QX1.01 DO QX1.02 DO QX1.03 DO/AO QX1.04 DO/AO QX1.05 DO QX1.06 DO QX1.07 DO/AO
SKTC1 48 49 31 50 51 52 16 35
/300.0
X44 48 49 31 50 51 52 16 35
+24VDC-IFM +24VDC-IFM
-305K0 A1 12 14
24VDC
-305K0
EEx nC /305.0
A1029768 A2 11
14 11 /305.1
12
-305D1 1 3
2x 60A 45V
EEx nA
A1066383 2 4
0VDC-E
0VDC-E
X42 21 22 X42 23
Ex e Ex e
W99 1 2
+/20.20
x1
x2
-305Z1
EEx nR
24Vdc 0,3A
A1104537
+/20.20
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
304 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Feb.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Safety controller Dashboard = CAB + ECP4 - 305
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W232
=CAB-W120
=CAB-W111
CABLE NAME
CABLE NAME
=CAB+ECP4-X42
TERMINAL STRIP X42 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
- =CAB+ECP4/200.0
- =CAB+ECP4/200.0
- =CAB+ECP4-X42 2 =CAB+ECP4/200.1
- =CAB+ECP4/200.1
- =CAB+ECP4-X42 4 =CAB+ECP4/200.1
- =CAB+ECP4/200.1
- =CAB+ECP4/200.1
25 =CAB+ECP2-X26 PE PE =CAB+ECP4/200.1
- =CAB+ECP4/200.1
- =CAB+ECP4/200.1
=CAB+ECP4-200F2 + =CAB+ECP4/200.2
- =CAB+ECP4/200.3
+ =CAB+ECP4/200.3
+ =CAB+ECP4/200.3
=CAB+ECP4-200K3 A2 - =CAB+ECP4/200.3
+ =CAB+ECP4-X42 8 =CAB+ECP4/200.3
+ =CAB+ECP4/200.3
+ =CAB+ECP4-200F3 =CAB+ECP4/200.4
+ =CAB+ECP4/200.4
+ =CAB+ECP4/200.4
+ =CAB+ECP4/200.4
9 =CAB+ECP2-X22 SP SP =CAB+ECP4/200.4
10 =CAB+ECP2-X22 - - =CAB+ECP4/200.4
=CAB+ECP4-200K4 A2 - =CAB+ECP4/200.4
8 =CAB+ECP4-X42 + =CAB+ECP4/200.5
9 =CAB+ECP4-200K3 A1 =CAB+ECP4/200.5
10 =CAB+ECP4-X42 8 =CAB+ECP4/200.5
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
305 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X42 TERMINAL STRIP X42 JUNCTION BOX = CAB + ECP4 - 1100
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W90
=CAB-W89
=CAB-W88
=CAB-W87
=CAB-W86
=CAB-W85
=CAB-W84
=CAB-W111
CABLE NAME
CABLE NAME
=CAB-W36
=CAB-W84
=CAB+ECP4-X42
TERMINAL STRIP X42 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
11 =CAB+ECP4-200K4 A1 =CAB+ECP4/200.6
=CAB+ECP4-200K4 11 + =CAB+ECP4/200.6
12 =CAB+ECP4-200K4 12 =CAB+ECP4/200.6
SP =CAB+ECP4/200.8
SP =CAB+ECP4/200.8
SP =CAB+ECP4/200.9
SP =CAB+ECP4/200.9
= - =CAB+ECP4/301.5
= - =CAB+ECP4/301.6
= BU =CAB+DSHB-302S1 SP =CAB+ECP4/302.1
= BN =CAB+DSHB-302S1 SP =CAB+ECP4/302.1
= BU =CAB+DSHB-302S2 SP =CAB+ECP4/302.2
= BN =CAB+DSHB-302S2 SP =CAB+ECP4/302.2
= BU =CAB+DSHB-302S3 SP =CAB+ECP4/302.3
= BN =CAB+DSHB-302S3 SP =CAB+ECP4/302.3
= BK =CAB+DSHB-302S6 SP =CAB+ECP4/302.6
= GY =CAB+DSHB-302S6 SP =CAB+ECP4/302.6
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X42 TERMINAL STRIP X42 JUNCTION BOX = CAB + ECP4 - 1101
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W99
=CAB-W97
=CAB-W96
=CAB-W95
=CAB-W94
=CAB-W93
=CAB-W92
=CAB-W91
CABLE NAME
CABLE NAME
=CAB+ECP4-X42
TERMINAL STRIP X42 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= BK =CAB+DSHB-302S7 SP =CAB+ECP4/302.7
= GY =CAB+DSHB-302S7 SP =CAB+ECP4/302.7
= BK =CAB+DSHB-302S8 SP =CAB+ECP4/302.8
= GY =CAB+DSHB-302S8 SP =CAB+ECP4/302.9
= BK =CAB+DSHB-303S7 + =CAB+ECP4/303.7
BN =CAB+DSHB-303S7
= BU =CAB+DSHB-304S1 SP =CAB+ECP4/304.1
= BN =CAB+DSHB-304S1 SP =CAB+ECP4/304.1
= - =CAB+ECP4/304.5
= - =CAB+ECP4/305.0
= 22 =CAB+ECP4/305.0
= 1 =CAB+-305Z1 x2 - =CAB+ECP4/305.1
= =CAB+ECP4-305K0 14 + =CAB+ECP4/305.1
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1103
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X42 TERMINAL STRIP X42 JUNCTION BOX = CAB + ECP4 - 1102
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W98
=CAB-W97
=CAB-W111
CABLE NAME
CABLE NAME
=CAB+ECP4-X42
TERMINAL STRIP X42 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
1 =CAB+ECP2-X22 5 + =CAB+ECP4/300.0
2 =CAB+ECP2-X22
4 =CAB+ECP2-X22
= - =CAB+ECP4/300.2
= - =CAB+ECP4-X44 15 =CAB+ECP4/300.2
= - =CAB+ECP4/300.2
= - =CAB+ECP4-X44 12 =CAB+ECP4/300.2
= - =CAB+ECP4/300.2
= - =CAB+ECP4-X44 33 =CAB+ECP4/300.2
= - =CAB+ECP4/300.2
= - =CAB+ECP4-300K4 12 =CAB+ECP4/300.2
= - =CAB+ECP4/300.2
= - =CAB+ECP4/300.2
= - =CAB+ECP4-300K4 A1 =CAB+ECP4/300.2
= - =CAB+ECP4/300.2
= - =CAB+ECP4-SKTC2 C =CAB+ECP4/300.2
= 6 =CAB+DSHB-304J5 SP =CAB+ECP4/304.6
= 7 =CAB+DSHB-304J5 SP =CAB+ECP4/304.6
= - =CAB+ECP4/304.7
= 6 =CAB+DSHB-304J5 SP =CAB+ECP4/304.8
= 7 =CAB+DSHB-304J5 SP =CAB+ECP4/304.8
=CAB+ECP4/200.4
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1104
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X42 TERMINAL STRIP X42 JUNCTION BOX = CAB + ECP4 - 1103
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W96
=CAB-W91
=CAB-W93
=CAB-W94
=CAB-W86
=CAB-W85
=CAB-W98
=CAB-W90
CABLE NAME
CABLE NAME
=CAB+ECP4-X44
TERMINAL STRIP X44 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
=CAB+ECP4-X44
=CAB+ECP4-301K1
=CAB+ECP4-X44
= 17 =CAB+ECP4-SKTC1 17 =CAB+ECP4/303.3
=CAB+ECP4-300R9
=CAB+ECP4-301K1
= 28 =CAB+ECP4-SKTC1 28 =CAB+ECP4/301.4
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1103 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1105
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X44 TERMINAL STRIP X44 JUNCTION BOX = CAB + ECP4 - 1104
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W89
=CAB-W88
=CAB-W87
=CAB-W98
=CAB-W97
=CAB-W96
=CAB-W95
=CAB-W94
CABLE NAME
CABLE NAME
=CAB+ECP4-X44
TERMINAL STRIP X44 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
=CAB+ECP4-X44
= 36 =CAB+ECP4-SKTC1 36 =CAB+ECP4/303.1
= 50 =CAB+ECP4-SKTC1 50 =CAB+ECP4/305.4
= 51 =CAB+ECP4-SKTC1 51 =CAB+ECP4/305.5
= 52 =CAB+ECP4-SKTC1 52 =CAB+ECP4/305.6
= 53 =CAB+ECP4-SKTC1 53 =CAB+ECP4/303.4
= 54 =CAB+ECP4-SKTC1 54 =CAB+ECP4/303.2
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1104 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1106
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X44 TERMINAL STRIP X44 JUNCTION BOX = CAB + ECP4 - 1105
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W93
CABLE NAME
CABLE NAME
=CAB+ECP4-X44
TERMINAL STRIP X44 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= + =CAB+ECP4-300K4 14 =CAB+ECP4/300.2
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1105 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1107
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X44 TERMINAL STRIP X44 JUNCTION BOX = CAB + ECP4 - 1106
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB+ECP4-X46
TERMINAL STRIP X46 JUNCTION BOX ECP4
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
+ =CAB+ECP4/200.0
+ =CAB+ECP4/200.0
+ =CAB+ECP4-200F0 =CAB+ECP4/200.0
+ =CAB+ECP4/200.0
+ =CAB+ECP4-X42 3 =CAB+ECP4/200.0
+ =CAB+ECP4/200.0
+ =CAB+ECP4/200.0
+ =CAB+ECP4/200.0
=CAB+ECP4/200.0
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1106 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP4#-X46 TERMINAL STRIP X46 JUNCTION BOX = CAB + ECP4 - 1107
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1107 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + ECP4 - 1500
0 1 2 3 4 5 6 7 8 9
ASEP B.V. II 3 G Ex nA nC II T 3
[EX] Epsilon Certified Safety controller IFM and Connector EX II 3
=CAB+ECP4-300U0 A1066396
G n II T3
[EX] ECOMAT100 CR7020 EX II 3 G n II T3 EPSILON07ATEX2224X A
ASEP B.V. II 3G Ex nA II T3
=CAB+ECP4-SKTC2 Mil Receptacle 10P Shell size 12 EEx nA (II 3G Ex nA II T3) A1083957
[EX] 62LC-12E12-10SN(771)-Amphenol EPSILON07ATEX2240X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP6/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + ECP4 - 2500
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP4/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 30
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 24.Feb.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + ECP6 - 1
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 28.Jan.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminal Strips & Connectors = CAB + ECP6 - 30
0 1 2 3 4 5 6 7 8 9
1 N
-100F0 1 3 1 3 -100F1 -100F7
Main Main Dehumidifier
Supply Supply 16A 30mA
L1 2 4 2 4 L2 C-kar
80A C-kar 80A C-kar A1109273
8501040894 8501040894
2 N.
-100F5A -100F5B
Frequency Frequency
1A 1A
A0000934 A0000934
A0020441 A0020441
A0020442 A0020442
-100F4A -100F4B
Voltage Voltage
Line B Line B
-100T1 1A 1A
150/5A A0000934 A0000934
A1081424 A0020441 A0020441
A0020442 A0020442
-100F3A -100F3B
Voltage Voltage AC AC.
-100T0
Line A Line A
150/5A
A1081424
1A 1A -100U5
A0000934 A0000934
A0020441 + -
A0020441
A0020442 A0020442
-100X7 L N PE
A1016387
+/20.2
+ECP2/100.9 / -L1-JB6-1
+ECP2/100.9 / -N1-JB6-1
+ECP2/100.9 / -L2-JB6-1
+ECP2/100.9 / -N2-JB6-1
+ECP2/100.9 / -PE-JB6-1
L1 L2 PE
-100A7
115V/60Hz
A1093830
Dehumidifier
+/20.2
Supply Switch Off
By Gas or Fire Alarm
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
30 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 15.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : 230V Supply's = CAB + ECP6 - 100
0 1 2 3 4 5 6 7 8 9
1 N 1 N
-101F1 -101F4
Wall Wall
Sockets 1-3 Sockets 4-7
16A 30mA 16A 30mA
C-kar C-kar
A1109273 A1109273
2 N. 2 N.
PE PE PE PE PE PE PE
X61 7 8 9 10 11 12 X61 13 14 15 16 17 18 19 20
W55 1 2 GN/YE W56 1 2 GN/YE W57 1 2 GN/YE W58 1 2 GN/YE W59 1 2 GN/YE W60 1 2 GN/YE W61 1 2 GN/YE
+/20.2 +/20.3 +/20.3 +/20.3 +/20.4 +/20.4 +/20.5
L N PE L N PE L N PE L N PE L N PE L N PE L N PE
Wall socket 1 Wall socket 2 Wall socket 3 Wall socket 4 Wall socket 5 Wall socket 6 Wall socket 7
(230VAC) (230VAC) (230VAC) (115VAC) (115VAC) (115VAC) (115VAC)
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 102
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 14.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : 115/230V Supply Wallsockets = CAB + ECP6 - 101
0 1 2 3 4 5 6 7 8 9
PE PE PE PE PE PE PE
W62 1 2 GN/YE W63 1 2 GN/YE W64 1 2 GN/YE W65 1 2 GN/YE W66 1 2 GN/YE W67 1 2 GN/YE W68 1 2 GN/YE
+/20.8 +/20.9 +/20.9 +/20.10 +/20.10 +/20.10 +/20.11
+CPRK
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 103
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 14.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : 115/230V Supply Computer System = CAB + ECP6 - 102
0 1 2 3 4 5 6 7 8 9
115VAC 60Hz
L1-JB6
N1-JB6
115VAC 60Hz
L2-JB6
N2-JB6
1 3 1 3 1 3 1 3
-103F2 -103F4 -103F6 -103F8
Airco 1 Airco 2 Airco 3 Airco 4
25A C-kar 20A C-kar 25A C-kar 20A C-kar
2 4 2 4 2 4 2 4
8501040074 8501040075 8501040074 8501040075
PE PE PE PE PE
X61 21 22 23 24 X61 25 26 X61 27 28 X61 29 30 X61 31 32
EEx e EEx e
W136 1 2 3 4 SH -103U6.1
+/20.5 Thermostat
+/20.7
1 2 3
1 2 3 W78.1
+/20.7
+ECP2/100.9 / -L1-JB6-2
+ECP2/100.9 / -N1-JB6-2
+ECP2/100.9 / -L2-JB6-2
+ECP2/100.9 / -N2-JB6-2
+ECP2/100.9 / -PE-JB6-2
1 2 PE 1 4 5 3 4 5 7 PE 1 2 PE 3 4 5 6 PE 1 2 PE 1 4 5 3 4 5 7 PE 1 2 PE 3 4 5 6 PE
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
Cabin airco
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 14.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Airco Supply = CAB + ECP6 - 103
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W60
=CAB-W59
=CAB-W58
=CAB-W57
=CAB-W56
=CAB-W55
=CAB-W54
=CAB-W53
CABLE NAME
CABLE NAME
=CAB+ECP6-X61
TERMINAL STRIP X61 JUNCTION BOX ECP6
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
SH =CAB+ECP2-X21 PE PE =CAB+ECP6/100.1
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
103 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP6#-X61 TERMINAL STRIP X61 JUNCTION BOX = CAB + ECP6 - 1100
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W68
=CAB-W67
=CAB-W66
=CAB-W65
=CAB-W64
=CAB-W63
=CAB-W62
=CAB-W61
CABLE NAME
CABLE NAME
=CAB+ECP6-X61
TERMINAL STRIP X61 JUNCTION BOX ECP6
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP6#-X61 TERMINAL STRIP X61 JUNCTION BOX = CAB + ECP6 - 1101
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W80
=CAB-W78
=CAB-W76
=CAB-W74
=CAB-W136
CABLE NAME
CABLE NAME
=CAB+ECP6-X61
TERMINAL STRIP X61 JUNCTION BOX ECP6
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
SH =CAB+ECP2-X21 PE PE =CAB+ECP6/103.1
= 3 =CAB+-103U2 PE PE =CAB+ECP6/103.2
= 3 =CAB+-103U4 PE PE =CAB+ECP6/103.4
= 3 =CAB+-103U6 PE PE =CAB+ECP6/103.6
= 3 =CAB+-103U8 PE PE =CAB+ECP6/103.8
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+ECP6#-X61 TERMINAL STRIP X61 JUNCTION BOX = CAB + ECP6 - 1102
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + ECP6 - 1500
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB10/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + ECP6 - 1501
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP6/1501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + EJB10 - 1
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W44
=CAB-W43
=CAB-W42
=CAB-W41
=CAB-W40
CABLE NAME
CABLE NAME
=CAB+EJB10-X102
TERMINAL STRIP X102 JUNCTION BOX EJB10
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 2 =CAB+EJB11-X112 2 2 =CAB/61.0
= 3 =CAB+EJB11-X112 3 3 =CAB/61.0
= 4 =CAB+EJB11-X112 4 4 =CAB/61.0
= 5 =CAB+EJB11-X112 5 5 =CAB/61.0
= 2 =CAB+EJB11-X112 7 7 =CAB/61.1
= 3 =CAB+EJB11-X112 8 8 =CAB/61.1
= 4 =CAB+EJB11-X112 9 9 =CAB/61.1
= 5 =CAB+EJB11-X112 10 10 =CAB/61.1
= 6 =CAB+EJB11-X112 11 11 =CAB/61.2
= 7 =CAB+EJB11-X112 12 12 =CAB/61.2
= 8 =CAB+EJB11-X112 13 13 =CAB/61.2
= 9 =CAB+EJB11-X112 14 14 =CAB/61.2
= 10 =CAB+EJB11-X112 15 15 =CAB/61.2
= 11 =CAB+EJB11-X112 16 16 =CAB/61.2
= 12 =CAB+EJB11-X112 17 17 =CAB/61.2
= 2 =CAB+EJB11-X112 19 19 =CAB/61.3
= 3 =CAB+EJB11-X112 20 20 =CAB/61.3
= 4 =CAB+EJB11-X112 21 21 =CAB/61.3
= 5 =CAB+EJB11-X112 22 22 =CAB/61.3
= 6 =CAB+EJB11-X112 23 23 =CAB/61.4
= 7 =CAB+EJB11-X112 24 24 =CAB/61.4
= 8 =CAB+EJB11-X112 25 25 =CAB/61.4
= 9 =CAB+EJB11-X112 26 26 =CAB/61.4
= 10 =CAB+EJB11-X112 27 27 =CAB/61.4
= 11 =CAB+EJB11-X112 28 28 =CAB/61.4
= 12 =CAB+EJB11-X112 29 29 =CAB/61.5
= 2 =CAB+EJB11-X112 31 31 =CAB/61.5
= 3 =CAB+EJB11-X112 32 32 =CAB/61.5
= 4 =CAB+EJB11-X112 33 33 =CAB/61.5
= 5 =CAB+EJB11-X112 34 34 =CAB/61.6
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+EJB10#-X102 TERMINAL STRIP X102 JUNCTION = CAB + EJB10 - 1100
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W45
=CAB-W44
CABLE NAME
CABLE NAME
=CAB+EJB10-X102
TERMINAL STRIP X102 JUNCTION BOX EJB10
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
= 3 =CAB+EJB11-X112 37 37 =CAB/61.6
= 4 =CAB+EJB11-X112 38 38 =CAB/61.6
= 5 =CAB+EJB11-X112 39 39 =CAB/61.7
= 6 =CAB+EJB11-X112 40 40 =CAB/61.7
= 7 =CAB+EJB11-X112 41 41 =CAB/61.7
= 8 =CAB+EJB11-X112 42 42 =CAB/61.7
= 9 =CAB+EJB11-X112 43 43 =CAB/61.7
= 10 =CAB+EJB11-X112 44 44 =CAB/61.7
= 11 =CAB+EJB11-X112 45 45 =CAB/61.8
= 12 =CAB+EJB11-X112 46 46 =CAB/61.8
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+EJB10#-X102 TERMINAL STRIP X102 JUNCTION = CAB + EJB10 - 1101
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + EJB10 - 1500
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB11/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + EJB10 - 2500
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+EJB10/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + EJB11 - 1
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB-W40
=CAB-W41
=CAB-W42
=CAB-W43
=CAB+EJB11-X112
TERMINAL STRIP X112 JUNCTION BOX EJB11
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
= 2 =CAB+EJB10-X102 2 2 =CAB/61.0
= 3 =CAB+EJB10-X102 3 3 =CAB/61.0
= 4 =CAB+EJB10-X102 4 4 =CAB/61.0
= 5 =CAB+EJB10-X102 5 5 =CAB/61.0
= 7 =CAB+EJB10-X102 7 2 =CAB/61.1
= 8 =CAB+EJB10-X102 8 3 =CAB/61.1
= 9 =CAB+EJB10-X102 9 4 =CAB/61.1
= 10 =CAB+EJB10-X102 10 5 =CAB/61.1
= 11 =CAB+EJB10-X102 11 6 =CAB/61.2
= 12 =CAB+EJB10-X102 12 7 =CAB/61.2
= 13 =CAB+EJB10-X102 13 8 =CAB/61.2
= 14 =CAB+EJB10-X102 14 9 =CAB/61.2
= 15 =CAB+EJB10-X102 15 10 =CAB/61.2
= 16 =CAB+EJB10-X102 16 11 =CAB/61.2
= 17 =CAB+EJB10-X102 17 12 =CAB/61.2
= 19 =CAB+EJB10-X102 19 2 =CAB/61.3
= 20 =CAB+EJB10-X102 20 3 =CAB/61.3
= 21 =CAB+EJB10-X102 21 4 =CAB/61.3
= 22 =CAB+EJB10-X102 22 5 =CAB/61.3
= 23 =CAB+EJB10-X102 23 6 =CAB/61.4
= 24 =CAB+EJB10-X102 24 7 =CAB/61.4
= 25 =CAB+EJB10-X102 25 8 =CAB/61.4
= 26 =CAB+EJB10-X102 26 9 =CAB/61.4
= 27 =CAB+EJB10-X102 27 10 =CAB/61.4
= 28 =CAB+EJB10-X102 28 11 =CAB/61.4
= 29 =CAB+EJB10-X102 29 12 =CAB/61.5
= 31 =CAB+EJB10-X102 31 2 =CAB/61.5
= 32 =CAB+EJB10-X102 32 3 =CAB/61.5
= 33 =CAB+EJB10-X102 33 4 =CAB/61.5
= 34 =CAB+EJB10-X102 34 5 =CAB/61.6
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+EJB11#-X112 TERMINAL STRIP X112 JUNCTION = CAB + EJB11 - 1100
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W112
CABLE NAME
CABLE NAME
=CAB-W44
=CAB-W45
=CAB-W112
=CAB+EJB11-X112
TERMINAL STRIP X112 JUNCTION BOX EJB11
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
= 36 =CAB+EJB10-X102 36 2 =CAB/61.6
= 37 =CAB+EJB10-X102 37 3 =CAB/61.6
= 38 =CAB+EJB10-X102 38 4 =CAB/61.6
= 39 =CAB+EJB10-X102 39 5 =CAB/61.7
= 40 =CAB+EJB10-X102 40 6 =CAB/61.7
= 41 =CAB+EJB10-X102 41 7 =CAB/61.7
= 42 =CAB+EJB10-X102 42 8 =CAB/61.7
= 43 =CAB+EJB10-X102 43 9 =CAB/61.7
= 44 =CAB+EJB10-X102 44 10 =CAB/61.7
= 45 =CAB+EJB10-X102 45 11 =CAB/61.8
= 46 =CAB+EJB10-X102 46 12 =CAB/61.8
= 50 =CAB+ECP2-X22 22 2 =CAB+ECP2/201.1
= 51 =CAB+ECP2-X22 23 3 =CAB+ECP2/201.1
= 53 =CAB+ECP2-X22 25 5 =CAB+ECP2/201.1
= 54 =CAB+ECP2-X22 26 6 =CAB+ECP2/201.1
= 56 =CAB+ECP2-X22 28 8 =CAB+ECP2/201.2
= 57 =CAB+ECP2-X22 29 9 =CAB+ECP2/201.2
= 59 =CAB+ECP2-X22 31 11 =CAB+ECP2/201.2
= 60 =CAB+ECP2-X22 32 12 =CAB+ECP2/201.3
= 62 =CAB+ECP2-X22 34 14 =CAB+ECP2/201.3
= 63 =CAB+ECP2-X22 35 15 =CAB+ECP2/201.3
= 65 =CAB+ECP2-X22 sp 17 =CAB+ECP2/201.4
= 19 =CAB+ECP2-X22 38 67 =CAB+ECP2/201.4
= sp =CAB+ECP2-X22 sp 20 =CAB+ECP2/201.5
= sp =CAB+ECP2-X22 sp 21 =CAB+ECP2/201.5
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+EJB11#-X112 TERMINAL STRIP X112 JUNCTION = CAB + EJB11 - 1101
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
CABLE NAME
CABLE NAME
=CAB-W112
=CAB+EJB11-X112
TERMINAL STRIP X112 JUNCTION BOX EJB11
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
= sp =CAB+ECP2-X22 sp 24 =CAB+ECP2/201.5
= PE =CAB+ECP2-X22 PE 25 =CAB+ECP2/201.5
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+EJB11#-X112 TERMINAL STRIP X112 JUNCTION = CAB + EJB11 - 1102
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + EJB11 - 1500
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB14/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + EJB11 - 2500
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+EJB11/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + EJB14 - 1
0 1 2 3 4 5 6 7 8 9
Terminal connectionlist
=CAB-W137
=CAB-W103
=CAB-W104
CABLE NAME
CABLE NAME
=CAB+EJB14-X142
TERMINAL STRIP X142 JUNCTION BOX EJB14
CABLETYPE
CONNECTION
TERMINAL
CONNECTION
CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN
1 =CAB+ECP2-X22
= 3 =CAB+ECP2-X22 - 3 =CAB+ECP2/301.8
= 2 =CAB+ECP2-X22 47 4 =CAB+ECP2/301.9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Terminalconnectionlist : =CAB+EJB14#-X142 TERMINAL STRIP X142 JUNCTION = CAB + EJB14 - 1100
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + EJB14 - 1500
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +DSHB/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + EJB14 - 2500
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
Dashboard
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+EJB14/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 31
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + DSHB - 1
0 1 2 3 4 5 6 7 8 9
CONNECTORS
=CAB+DSHB-300P4-A = A Cantrak
=CAB+DSHB-PLGA = PLGA Cantrak
=CAB+DSHB-210U0 = Operator Panel
=CAB+DSHB-210U8 = Kerr Backup Display
=CAB+DSHB-J1 = J1 Power Supply 12-24V
=CAB+DSHB-J2 = J2 Loadcell
=CAB+DSHB-J3 = J3 Encoder 1
=CAB+DSHB-J4 = J4 MMD
=CAB+DSHB-J5 = J5 Encoder 2
=CAB+DSHB-J9 = J9 Tension Contact
=CAB+DSHB-P33 = P33 Encoder 3
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 210
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 15.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors = CAB + DSHB - 31
0 1 2 3 4 5 6 7 8 9
+DSHB
Kerr Backup
Encoder 3
-210U0 -210U8
OPERATOR Kerr Backup
PANEL Display
AMS4A043 AM5KP112
A1058684 A1050574
J1 1 2 J5 J4 J9 J9 D E C J2 A B C D E F G H P33 C D E F
J L C E A B F J L C E A B F /210.5
A B C E G J A
+ECP4/200.1 / -OP-0VDC
+ECP4/200.1 / -BP-12VDC
+ECP4/200.2 / -BP-0VDC
+ECP4/200.2 / -BP-EARTH
+
+BLKH/200.4
+BLKH/200.2
+BLKH/200.0
+BLKH/200.2
+BLKH/200.0
+/21.1 +/21.2 +/21.1 +/21.3 +/21.11 +/21.0
+BLKH/200.4 +BLKH/200.2 +BLKH/200.4 +BLKH/200.0 +BLKH/200.2 +BLKH/200.0
Encoder 1 Encoder 2 Loadpin MMD Intercom 1 Encoder 3
SKT51a A B C D E G F SKT52a A B C D E G F SKT50a A B C D E F G H J K SKT56a A B C D E F G H J K SKT57a A B C D E F SKT53a A B C D E F
PLG57
Intercom 1 A B C D E F
A1068678
A1082716
WRL 1 2
+/21.11
-210W7
+/21.11
W180 1 2
+/21.11
Connections to: Connections to: Connections to: Connections to: Connections to:
WNCH page 210 WNCH page 210 WNCH page 210 WNCH page 210 x1 WNCH page 210
x2
-210Z7
A1070818
+/21.11
Encoder 1
Loadpin Encoder 2
Loadpin Loadpin Loadpin
MMD Encoder 3
Loadpin
Intercom Speaker
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
31 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 13.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Operator Panel = CAB + DSHB - 210
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
210 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + DSHB - 1500
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + DSHB - 1501
0 1 2 3 4 5 6 7 8 9
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2501
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + DSHB - 2500
0 1 2 3 4 5 6 7 8 9
Amphenol Ex II 3 G nA II T3
=CAB+DSHB-J1 EX Straight socket, 3S, Shell size 12 (KPSE series) A1068695
83302170 EPSILON 07 ATEX 2240X A
Amphenol Ex II 3 G Ex nA II T3
=CAB+DSHB-J4 EX Straight plug, 12P, Shell size 14 (KPSE series) A1068692
83302167 EPSILON 07 ATEX 2240X A
Amphenol Ex II 3 G Ex nA II T3
=CAB+DSHB-J5 EX Straight plug, 12P, Shell size 14 (KPSE series) A1068692
83302167 EPSILON 07 ATEX 2240X A
Amphenol Ex II 3 G Ex nA II T3
=CAB+DSHB-P33 EX Straight plug, 12P, Shell size 14 (KPSE series) A1068692
83302167 EPSILON 07 ATEX 2240X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +CPRK/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + DSHB - 2501
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
Computer Rack
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+DSHB/2501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 31
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + CPRK - 1
0 1 2 3 4 5 6 7 8 9
CONNECTORS
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 24.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors = CAB + CPRK - 31
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
31 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +BLKH/1
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + CPRK - 1500
0 1 2 3 4 5 6 7 8 9
National Oilwell Varco Corporate Headquarters 7909 Parkwood Circle Dr. Houston, TX 77036 Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
Cabin
Bulkhead
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+CPRK/1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 31
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 11.Aug.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Frontpage = CAB + BLKH - 1
0 1 2 3 4 5 6 7 8 9
WELLHEAD
MONITOR GREEN LIGHT RF ANTENNA =CAB+BLKH-PLG50a = PLG50a Bulkhead Loadcell
=CAB+BLKH-SKT50a =
=CAB+BLKH-PLG51a = PLG51a Bulkhead Encoder 2
=CAB+BLKH-SKT51a =
62 61 63 =CAB+BLKH-PLG52a = PLG52a Bulkhead Encoder 3
=CAB+BLKH-SKT52a =
=CAB+BLKH-PLG53a = PLG53a Bulkhead Encoder 1
=CAB+BLKH-SKT53a =
=CAB+BLKH-PLG54a = PLG54a Bulkhead Rig Display
=CAB+BLKH-SKT54a =
MARK =CAB+BLKH-PLG55a = PLG54a Bulkhead Mark Intensifier
INTENSIFIER SP/ DLL RIG DISPLAY =CAB+BLKH-SKT55a =
=CAB+BLKH-PLG56a = PLG56a Bulkhead Mark Detector
=CAB+BLKH-SKT56a =
=CAB+BLKH-PLG57a = PLG57a Bulkhead Intercom 1
55 59 54 =CAB+BLKH-SKT57a =
MARK
DETECTOR INTERCOM LOAD CELL
56 57 50
MMD
A1097290
FRONT
(Winch side)
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 200
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 20.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors = CAB + BLKH - 31
0 1 2 3 4 5 6 7 8 9
+BLKH
+/250.2
A1061220 +/250.4
A1068671 A1058159
Wellhead A1068670 /200.4
Monitor Green light RF Antenna WELLHEAD
SKT62a SKT61a SKT63a MONITOR GREEN LIGHT RF ANTENNA
+/250.3 +/250.4 62 61 63
+/21.12 MARK
A1061220 +/214.3 INTENSIFIER SP/ DLL RIG DISPLAY
A1068671 A1058159 A1058159
Mark A1068670 A1068673
Intensifier SP/DLL Rig Display
SKT55a SKT59a SKT54a
MARK
DETECTOR INTERCOM LOAD CELL
A1097290
FRONT
(Winch side)
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
31 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 20.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Connectors Bulkhead = CAB + BLKH - 200
0 1 2 3 4 5 6 7 8 9
Bill of materials
CODE Σ SPECIFICATIONS SUPPLIER PART NUMBER PAGE COLUMN
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
200 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Bill of materials electric = CAB + BLKH - 1500
0 1 2 3 4 5 6 7 8 9
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT50a EX Thru Bulkhead Receptacle 10PS, Shell size 12 A1068674
PTB12-10PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT51a EX Thru Bulkhead receptacle 8PS, Shell size 12 A1068673
PTB12-8PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT52a EX Thru Bulkhead receptacle 8PS, Shell size 12 A1068673
PTB12-8PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT54a EX Thru Bulkhead receptacle 8PS, Shell size 12 A1068673
PTB12-8PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT55a EX Thru bulkhead Receptacle 5PS, Shell size 14 A1068671
PTB14-5PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT56a EX Thru Bulkhead Receptacle 10PS, Shell size 12 A1068674
PTB12-10PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT59a EX Thru Bulkhead Receptacle 3PS, Shell size 12 A1068670
PTB12-3PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT61a EX Thru Bulkhead Receptacle 3PS, Shell size 12 A1068670
PTB12-3PS (Ex nA) Epsilon 07 ATEX 2240X A
ASEP B.V. Ex ll 3G Ex nA ll T3
=CAB+BLKH-SKT62a EX Thru bulkhead Receptacle 5PS, Shell size 14 A1068671
PTB14-5PS (Ex nA) Epsilon 07 ATEX 2240X A
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE =INF+/2600
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Hazardous area schedule = CAB + BLKH - 2500
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
=CAB+BLKH/2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2601
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2600
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2600 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2602
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2601
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2601 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2603
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2602
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2602 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2604
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2603
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2603 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2605
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2604
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2604 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2606
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2605
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2605 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2607
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2606
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2606 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2608
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2607
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2607 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2609
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2608
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2608 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2610
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2609
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2609 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2611
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2610
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2610 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2612
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2611
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2611 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2613
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2612
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2612 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2614
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2613
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2613 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2615
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2614
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2614 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2616
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2615
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2615 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2617
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2616
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2616 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2618
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2617
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2617 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2619
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2618
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2618 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2620
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2619
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2619 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2621
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2620
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2620 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2622
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2621
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2621 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2623
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2622
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2622 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2624
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2623
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2623 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2625
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2624
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2624 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2626
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2625
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2625 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2627
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2626
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2626 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2628
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2627
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2627 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2629
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2628
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2628 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2630
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2629
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2629 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2631
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2630
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2630 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2632
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2631
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2631 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2633
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2632
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2632 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2634
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2633
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2633 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2635
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2634
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2634 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2636
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2635
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2635 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2637
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2636
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2636 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2638
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2637
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2637 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2639
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2638
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2638 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2640
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2639
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2639 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2641
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2640
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2640 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2642
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2641
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2641 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2643
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2642
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2642 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2644
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2643
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2643 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2645
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2644
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2644 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2646
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2645
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2645 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2647
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2646
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2646 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2648
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2647
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2647 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2649
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2648
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2648 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2650
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2649
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2649 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2651
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2650
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2650 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2652
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2651
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2651 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2653
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2652
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2652 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2654
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2653
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2653 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2655
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2654
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2654 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2656
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2655
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2655 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2657
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2656
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2656 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2658
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2657
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2657 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2659
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2658
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2658 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2660
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2659
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2659 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2661
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2660
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2660 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2662
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2661
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2661 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2663
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2662
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2662 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2664
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2663
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2663 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2665
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2664
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2664 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2666
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2665
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2665 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2667
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2666
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2666 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2668
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2667
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2667 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2669
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2668
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2668 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2670
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2669
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2669 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2671
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2670
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2670 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2672
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2671
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2671 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2673
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2672
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2672 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2674
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2673
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2673 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2675
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2674
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2674 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2676
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2675
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2675 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2677
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2676
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2676 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2678
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2677
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2677 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2679
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2678
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2678 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2680
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2679
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2679 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2681
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2680
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2680 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2682
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2681
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2681 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2683
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2682
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2682 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2684
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2683
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2683 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2685
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2684
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2684 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2686
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2685
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2685 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2687
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2686
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2686 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2688
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2687
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2687 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2689
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2688
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2688 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2690
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2689
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2689 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2691
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2690
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2690 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2692
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2691
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2691 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2693
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2692
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2692 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2694
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2693
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2693 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2695
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2694
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2694 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2696
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2695
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2695 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2697
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2696
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2696 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2698
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2697
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2697 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2699
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2698
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2698 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2700
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2699
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2699 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2701
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2700
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2700 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2702
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2701
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2701 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2703
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2702
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2702 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2704
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2703
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2703 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2705
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2704
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2704 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2706
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2705
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2705 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2707
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2706
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2706 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2708
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2707
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2707 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2709
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2708
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2708 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2710
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2709
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2709 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2711
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2710
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2710 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2712
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2711
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2711 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2713
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2712
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2712 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2714
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2713
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2713 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2715
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2714
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2714 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2716
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2715
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2715 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2717
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2716
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2716 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2718
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2717
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2717 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2719
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2718
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2718 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2720
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2719
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2719 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2721
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2720
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2720 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2722
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2721
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2721 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2723
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2722
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2722 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2724
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2723
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2723 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2725
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2724
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2724 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2726
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2725
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2725 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2727
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2726
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2726 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2728
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2727
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2727 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2729
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2728
0 1 2 3 4 5 6 7 8 9
Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X
Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are
X X X
Apparatus
Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X
Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X
Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for
X X X
example connections are tight and conductors are of sufficient cross-section)
Installation
Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X
THIS DRAWING IS THE PROPERTY OF ELMAR NOV. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2728 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE
C 8974
G.Martina
M. Kleijn M. Kleijn RELEASED TITLE : CABIN EXTRA LONG DATASPLIT C HIGHER LEVEL LOCATION PAGE:
16-09-2011 ASSIGNMENT: DESIGNATION:
REV. ECO DRAWN CHECKED APPROVED PRINT STATUS National Oilwell Varco Corporate Headquarters
DRAWING No. : ES6931033757
Format: A4 PAGE MOD 16.Sep.2011
7909 Parkwood Circle Dr. Houston, TX 77036
Phone: 1 888 262 8645 www.NOV.com/ASEPElmar
PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2729