You are on page 1of 89

0 1 2 3 4 5 6 7 8 9

TITLE : POWERPACK DATASPLIT C

DRAWING No. : ES6931033721

REGULATIONS : ATEX

RISK CATEGORY : Cat 3G, IIA, T3

AREA CODE : Zone 2

DESIGN TEMPERATURE : -20°C / +40°C

MAIN SUPPLY : 2x115V 60Hz

NOTE : --

H.Tuytelaars
E1 P. Muilwijk A. Korevaar Controller Overview Added
Total number of pages : 89 12 Feb. 2015

REV. ECO DRAWN CHECKED APPROVED REMARK

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Frontpage = GEN + - 1
0 1 2 3 4 5 6 7 8 9

Higher Level Assignment- / Location Designation overview


CODE Higher Level Assignment DESCRIPTION Higher Level Assignment CODE Location Designation DESCRIPTION Location Designation

=GEN General +24V

=PWRP Powerpack +ECP1 ECP1 = PWRP 2x115V 125A GEN 30kW ATX 8501036539

=INF Information +ECP3 ECP3 = PWRP 24V CAT6.6 IFM ATX 8501035867

+EJB8 EJB 160X160X90 POLY ATX ASSY BATTERY - A1054425 EJB8 PWRP Battery connection box

+EJB9 EJB 220x220x120 SS ATX ASSY PWRP SUP. - 8501036543 EJB9 PWRP shore connection

+EJB17 EJB 110x75x55 POLY ATX ASSY - A1070273 EJB17 PWRP Speed sensor box

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Higher level assignment- / location designation overview = GEN + - 2
0 1 2 3 4 5 6 7 8 9

Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR

=GEN/1 Frontpage 06.Feb.2015 TuytelaarsH

=GEN/2 Higher level assignment- / location designation overview 06.Feb.2015 TuytelaarsH

=GEN/3 Page overview 11.Feb.2015 tuytelaarsh

=GEN/3.a Page overview 11.Feb.2015 tuytelaarsh

=GEN/3.b Page overview 06.Feb.2015 TuytelaarsH

=PWRP/1 Frontpage 01.Jul.2014 tuytelaarsh

=PWRP/20 Block Diagram 15.Jan.2015 bosr

=PWRP/24 Single Line Power Distribution PWRP 02.Jul.2014 tuytelaarsh

=PWRP/32 Electric symbol overview 06.Oct.2011 MartinaG2

=PWRP+ECP1/1 Frontpage 11.Aug.2011 tuytelaarsh

=PWRP+ECP1/100 Generator Control 10.Feb.2015 tuytelaarsh

=PWRP+ECP1/1100 Terminalconnectionlist : =PWRP+ECP1#-X11 06.Feb.2015 TuytelaarsH

=PWRP+ECP1/1101 Terminalconnectionlist : =PWRP+ECP1#-X12 06.Feb.2015 TuytelaarsH

=PWRP+ECP1/1102 Terminalconnectionlist : =PWRP+ECP1#-X14 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1a Frontpage 09.Jul.2014 tuytelaarsh

=PWRP+ECP3/200 Control Circuit Generator Control 15.Jan.2015 bosr

=PWRP+ECP3/201 Control Circuit Generator Control 15.Jan.2015 bosr

=PWRP+ECP3/300 Safety controller EX 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/301 Safety controller 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/302 Safety controller 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/303 Safety controller 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/304 Safety controller 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/305 Safety controller 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/306 Controller Overview 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/1100 Terminalconnectionlist : =PWRP+ECP3#-0VDC-E 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/1101 Terminalconnectionlist : =PWRP+ECP3#-0VDC-E 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1102 Terminalconnectionlist : =PWRP+ECP3#-X32 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1103 Terminalconnectionlist : =PWRP+ECP3#-X32 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1104 Terminalconnectionlist : =PWRP+ECP3#-X32 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/1105 Terminalconnectionlist : =PWRP+ECP3#-X34 11.Feb.2015 tuytelaarsh

=PWRP+ECP3/1106 Terminalconnectionlist : =PWRP+ECP3#-X34 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1107 Terminalconnectionlist : =PWRP+ECP3#-X34 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1108 Terminalconnectionlist : =PWRP+ECP3#-X38 06.Feb.2015 TuytelaarsH

=PWRP+ECP3/1109 Terminalconnectionlist : =PWRP+ECP3#-X200F0 06.Feb.2015 TuytelaarsH

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.a

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Page overview = GEN + - 3
0 1 2 3 4 5 6 7 8 9

Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR

=PWRP+ECP3/1110 Terminalconnectionlist : =PWRP+ECP3#-X300F2 11.Feb.2015 tuytelaarsh

=PWRP+EJB8/1 Frontpage 11.Aug.2011 tuytelaarsh

=PWRP+EJB8/1100 Terminalconnectionlist : =PWRP+EJB8#-X82 06.Feb.2015 TuytelaarsH

=PWRP+EJB9/1 Frontpage 11.Aug.2011 tuytelaarsh

=PWRP+EJB9/1100 Terminalconnectionlist : =PWRP+EJB9#-XB 06.Feb.2015 TuytelaarsH

=PWRP+EJB17/1 Frontpage 11.Aug.2011 tuytelaarsh

=PWRP+EJB17/1100 Terminalconnectionlist : =PWRP+EJB17#-X172 11.Feb.2015 tuytelaarsh

=INF/1400 Cable overview : 06.Feb.2015 TuytelaarsH

=INF/1401 Cable overview : 11.Feb.2015 tuytelaarsh

=INF/1402 Cable overview : 11.Feb.2015 tuytelaarsh

=INF/1403 Cable overview : 06.Feb.2015 TuytelaarsH

=INF/1500 Bill of materials electric 06.Feb.2015 TuytelaarsH

=INF/1501 Bill of materials electric 06.Feb.2015 TuytelaarsH

=INF/1502 Bill of materials electric 06.Feb.2015 TuytelaarsH

=INF/1503 Bill of materials electric 06.Feb.2015 TuytelaarsH

=INF/1504 Bill of materials electric 06.Feb.2015 TuytelaarsH

=INF/1505 Bill of materials electric 06.Feb.2015 TuytelaarsH

=INF/2500 Hazardous area schedule 06.Feb.2015 TuytelaarsH

=INF/2501 Hazardous area schedule 06.Feb.2015 TuytelaarsH

=INF/2502 Hazardous area schedule 06.Feb.2015 TuytelaarsH

=INF/2600 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2601 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2602 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2603 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2604 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2605 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2606 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2607 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2608 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2609 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2610 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2611 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2612 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2613 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 3.b

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Page overview = GEN + - 3.a
0 1 2 3 4 5 6 7 8 9

Page overview
PAGE DESIGNATION REMARKS MOD.DATE REVISOR

=INF/2614 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2615 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2616 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2617 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2618 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2619 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2620 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2621 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2622 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2623 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2624 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2625 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2626 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2627 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2628 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2629 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2630 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2631 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2632 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2633 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

=INF/2634 Electrical inspection sheet 06.Feb.2015 TuytelaarsH

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
3.a PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE =PWRP/1

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Page overview = GEN + - 3.b
0 1 2 3 4 5 6 7 8 9

Powerpack

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
=GEN/3.b PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 20

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 01.Jul.2014 PAGE DESCRIPTION : Frontpage = PWRP + - 1
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

-SKT1A +EJB9 -PLG6 -SKT2


+ECP1/100.9 +ECP3/200.3 +ECP3/200.4 +ECP3/300.9

XB

W1 W10 W11
RADOX RADOX SABIX-Multi
5.5 meter 3 meter 3 meter
4x25 mm² 4x6 mm² 25xSpcl mm²
+ECP3/200.6
+ECP1/100.9 +ECP3/200.3
+ECP3/300.9
+ECP1/100.9 +ECP3/200.4
+ECP3/304.5
+ECP3/200.4
+ECP3/200.7
+ECP3/200.7
+ECP3/200.7
+ECP1 +ECP3 +ECP3/200.7
+ECP3/200.8
+ECP1/100.0 +ECP3/200.0 +ECP3/200.8
+ECP3/300.9
+ECP3/300.9
+ECP3/304.5
X11 X32
PWRP Juctionbox ECP1 +ECP3/304.5

X32
PWRP Juctionbox ECP3

301U3 301U3
X11 X14 X11 X12 X32 X34 X32 X32 X32 X38 X32 X32 X34 X34 X34 X34 X34 X32 X32 X32 X32 X32 X38 X38 X38 X34 X34 X34

W2 W3 W4 W5 W6 W7 IS-ECP3 W12 W13 W14 W15 W16 W17 W18 W19 W20 W21 W22 W24 W25 W26 W27 W28 W29a W30 W31 W32 W33
RADOX RADOX RADOX RADOX RADOX GEXOL SABIX RADOX RADOX RADOX RADOX RADOX IS CON. IS CON. RADOX RADOX Molded-a3 RADOX RADOX RADOX RADOX RADOX IS CON. IS CON. IS CON. RADOX RADOX Molded-a3
3 meter 3 meter 5.5 meter 3 meter 4 meter 3.5 meter 3.5 meter 2.5 meter 2 meter 3 meter 3 meter 3 meter 2 meter 4 meter 3 meter 6 meter 3x1,5 mm² 3 meter 3 meter 3.5 meter 3 meter 3 meter 3 meter 2 meter 3 meter 3.5 meter 4 meter 3 meter
4x25 mm² 3x2,5 mm² 3x4 mm² 7x1 mm² 5x2,5 mm² 1x8 AWG 18x1 mm² 2x1,5 mm² 3x1 mm² 3x1 mm² 3x1 mm² 2x0,75 mm² 2x0,75 mm² 3x1 mm² 2x1,5 mm² +ECP3/302.3 6x0,5 mm² 3x1 mm² 3x1 mm² 3x1 mm² 3x1 mm² 2x0,75 mm² 2x0,75 mm² 2x0,75 mm² 2x1,5 mm² 2x1,5 mm² 3x1,5 mm²
1x6 mm² +ECP3/302.4
+ECP1/100.0 +ECP1/100.1 +ECP1/100.7 +ECP1/100.5 +ECP3/200.0 +ECP3/200.1 +ECP3/201.0 +ECP3/201.4 +ECP3/301.1 +ECP3/301.2 +ECP3/301.3 +ECP3/301.6 +ECP3/302.2 +ECP3/302.7 +ECP3/303.1 +ECP3/303.2 +ECP3/303.3 +ECP3/303.4 +ECP3/304.1 +ECP3/304.6 +ECP3/305.1
+ECP1/100.0 +ECP1/100.1 +ECP1/100.7 +ECP1/100.6 +ECP3/200.1 Blue +ECP3/201.4 +ECP3/201.5 +ECP3/301.1 +ECP3/301.2 +ECP3/301.3
Blue Blue +ECP3/301.6 +ECP3/302.2 +ECP3/302.4 +ECP3/302.8 +ECP3/303.1 +ECP3/303.2 +ECP3/303.3 +ECP3/303.4
Blue Blue Blue +ECP3/304.1 +ECP3/304.6 +ECP3/305.1
+ECP1/100.0 +ECP1/100.1 +ECP1/100.7 +ECP3/200.1 -200S1 Marking +ECP3/201.4 +ECP3/201.5 +ECP3/301.1 +ECP3/301.2 +ECP3/301.3 Marking Marking +ECP3/301.6 +ECP3/302.2 +ECP3/302.8 +ECP3/303.1 +ECP3/303.2 +ECP3/303.3 +ECP3/303.4 Marking Marking Marking +ECP3/304.1 +ECP3/304.6 +ECP3/305.1
+ECP3/200.1 +ECP3/301.4 +ECP3/301.5 +ECP3/303.8 +ECP3/303.8 +ECP3/303.9
+ECP3/200.2
2 +ECP3/301.4 +ECP3/301.5 +ECP3/303.8 +ECP3/303.8 +ECP3/303.9
+ECP3/301.4 +ECP3/301.5 +ECP3/303.8 +ECP3/303.8 +ECP3/303.9
+EJB17 X172
G +ECP3/302.7 +ECP3/303.8
SKT11
-PLG11
+ECP3/303.8

-200G0 W8 W9 P + -
P
Alternator GEXOL GEXOL W29
+ECP3/200.0 IS +ECP3/201.4 -301B2 -301B6 W23 IS CON.
2.5 meter 2 meter
MASSA -SKT9 Control Air Molded-SP5 0.5 meter
2 1x8 AWG 1x8 AWG -303S9 -304S6
+ECP3/200.1 +ECP3/200.2 +ECP3/200.2 Pressure -301B4 Pressure -302Y3 0.5 m -303Y1 -303Y3 2x0,75 mm²
1/N/PE -PLG9 4-20mA 4-20mA Air-inlet Valve 5x0.35 mm² Generator Winchpump Coolant Low
P1 +ECP3/201.4
Exhaust Blue
G +ECP3/201.0
+ECP3/301.2 Temperature +ECP3/301.6 +ECP3/302.3 +ECP3/302.7 pump Out Hole
Marking
Temp.
+ECP3/303.9
Coolant
Level
4-20mA +ECP3/303.1 +ECP3/303.3
-100X7 +ECP3/303.8 +ECP3/304.6
+ECP3/301.4
Auxiliary +ECP3/303.8
Power P P + -
+ECP3/303.8
-304S1 -305Y1
Socket
Low Hydr. Start
-100G0
+ECP1/100.7
+EJB8 X82 -201U0 -301B1 -301B3 -302S8 -303Y2 -303Y4 Oil Level Engine
Generator +ECP3/200.1 P1 Main Main -302Y2 Speedsensor Relief Valve Winchpump +ECP3/304.1 +ECP3/305.1

2x115V 60Hz Engine ECU Pressure Generator -301B5 +ECP3/302.2 Generator Drum In Hole P
30Kw +ECP3/201.0 4-20mA Pressure Hydraulic Oil +ECP3/302.7
+ECP3/303.2 +ECP3/303.4
+ECP1/100.0 +ECP3/301.1 4-20mA Temperature
+ECP3/301.3 4-20mA -303B8 -303S8
WB1 WB2 C2 -201H4 +ECP3/301.5 Oil Exhaust
WB3 Portable Pressure Temp.
Molded-BK Molded-BK RADOX P1 Light +ECP3/303.7 +ECP3/303.8
1x35 mm² 1x35 mm² 3.5 meter +ECP3/201.4
+ECP3/200.1 +ECP3/200.2 1x35 mm²
+ECP3/200.2
-201U3
+ECP3/201.3

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
-200B1 PE 1 PREVIOUS PAGE AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
2x115V 60Hz NEXT PAGE 24
+ECP3/200.1

+ECP1/100.2 E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

POWERPACK REV.

Format: A1
ECO DRAWN CHECKED

Ronald Bos
APPROVED

15.Jan.2015
PRINT STATUS
DRAWING No. :

PAGE DESCRIPTION :
ES6931033721
Block Diagram = PWRP + - 20
PAGE MOD
0 1 2 3 4 5 6 7 8 9

=PWRP+ECP1

2PH x 115VAC 60Hz (ECP1)


X11 X11

100K2
Contactor
+ECP1/100.2

-100Q0 3
100F1 1 100F2 1 100F3 1 100F0A 1 100F0B 1 100F5 1 -100F7 2
Main Power Voltage Voltage Voltage Under/overvoltage Under/overvoltage Voltage Auxilliary
2x 115Vac Regulator Regulator Regulator relay relay Converter Supply
125A 5A 5A 5A 1A 1A 1A 32A
+ECP1/100.0 +ECP1/100.1 +ECP1/100.2 +ECP1/100.2 +ECP1/100.1 +ECP1/100.1 +ECP1/100.5 +ECP1/100.7

100K1
Contactor
+ECP1/100.1

-100B0 -100B5
Voltage
-100K1 -100K2 Voltage
M M
+ECP1/100.1 +ECP1/100.2
Regulator Converter
+ECP1/100.1 +ECP1/100.5
=PWRP+

1/N/PE 3/N/PE

-100G0 -100X7 -SKT1A


Generator Auxiliary Main Power
2x115V 60Hz Power Supply
30Kw Socket To Cabin
+ECP1/100.0 +ECP1/100.7 +ECP1/100.9

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
20 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 32

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 02.Jul.2014 PAGE DESCRIPTION : Single Line Power Distribution PWRP = PWRP + - 24
0 1 2 3 4 5 6 7 8 9

ELECTRIC SYMBOL OVERVIEW


SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION

+ -
TERMINAL PROXIMITY SWITCH VALVE

CONNECTOR BATTERY CAPACITOR

SOCKET G GENERATOR INDUCTIVITY

PLUG TRANSFORMER RESISTOR

COIL (FOR CONTACTOR) CONVERTER / RECTIFIER DIODE (SEMICONDUCTOR)

NORMALY OPEN CONTACT SIGNAL LAMP EARTH / GROUND

NORMALY CLOSED CONTACT ACOUSTIC SIGNAL DEVICE (HORN)

CHANGE-OVER CONTACT MEASURING INSTRUMENT

M
SAFETY FUSE MOTOR
1~

CIRCUITBREAKER LIGHT

MOTOR-OVERLOAD SWITCH HEATING


I> I> I>

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
24 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP1/1

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD G. Martina 06.Oct.2011 PAGE DESCRIPTION : Electric symbol overview = PWRP + - 32
0 1 2 3 4 5 6 7 8 9

Powerpack

ECP1 = PWRP 2x115V 125A GEN 30kW ATX


8501036539

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+/32 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 100

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Aug.2011 PAGE DESCRIPTION : Frontpage = PWRP + ECP1 - 1
0 1 2 3 4 5 6 7 8 9

+-ECP1 2x115VAC 60Hz L1


8501036539 N
L2
-100T4
1 3 5 300A/4-20mA
8501058572 -100F5 -100F7 1 3
-100K2 Voltage Auxilliary
/100.2 Converter Supply
2 4 6 1A 2 4
3UG4633-1AL30 32A D-kar
Ia+ Ia- UH+ UH- A0000934
1-OFF delay on alarm 8501040832

2-OFF nor.energized
-100F0A
Under/overvoltage 3-ON 6s +/- 0,5s
relay 4-OFF inhibit fun.an.
1A
A0010259 5-ON 230V
6-OFF 230V
-100B5
11 Voltage 5 7
1 2 Converter
-100K1 A1059744
+/24.3 12 14 8501040842 3 2 1 9 10
-100H2/100.1 -100H3 8501040843
-100K1 A1
Voltage Voltage
DP1
1 2 3 4 5 6 7 8
17-275VAC/DC M Error OK on
Set 207V-253V RD GN off
On = 0,1sec A2
LED 230V A1 LED 230V
Off = 5sec A1035286 A1105420 DP2
A1112821 A1105420 A1035290 1 2 3 4
on
A2 off
1 2
14 11 /100.2 -100K2 1 2 /100.0 JP1
-100F0B 12 80A 37kW 3 4 /100.0
Under/overvoltage A1086670
relay 5 6 /100.0 1 2 3
1A 8501056374 13 14
A0010259 For settings check EWI 21 22
Voltage
Regulator
-100B0

-100Q0 AVC63-4A
2 50/60Hz
Main Power
2x 115Vac F- F+ V1 V2 3 4 E3 E1 HZ1 HZ2 6 7
125A C-kar 1
MAIN
-100F1 2 2 2
FUSE -100F3
SWITCH Voltage Voltage
8501040837 Regulator Regulator
8501040839 5A 1 1 1 5A
8501040840 A0015575 A0015575
-100F2
Voltage
Regulator
5A
A0015575

PE PE
PE PE PE
X11 1 2 3 X14 1 2 X12 1 2 3 4 5 6 X11 7 8 X11 sp sp sp X11 4 5 6

Ex d Ex d

W2 4 1 2 3 W3 1 2 3 W5 1 2 3 4 5 6 7 W4 1 2 3 W1 1 2 3 4
+/20.0 +/20.1 +/20.3 +/20.1 +/20.2

115V 0V 115V
-100G0 1 PE N R1 N(S2) T3 N PE
A1059353

-SIGN1
+ECP3/301.8

SIGN2
+ECP3/301.8

-SIGN3
+ECP3/301.7

SIGN4
+ECP3/301.7

-SP1
+ECP3/200.9

-SP2
+ECP3/200.9

-PE
+ECP3/200.9
PE.. L1 N L2 F- F+ PE. +/20.0

T1 T4 F-
SKT1A
H1 H2 F -100X7 *125A EX-d
PE. A0019870 A1059801
T2 T3 F+ A0019869 A1059800
A0019871 +/24.6

PE A0019872
A0019873 Connections to:
PE CAB+ECP2
GENERATOR
page 100
Serial number:
2x 115V 60Hz
125A 30Kw Type:
Voltage Voltage / Current Auxiliary Main Power
regulation signals Power Supply
Socket To Cabin

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 10.Feb.2015 PAGE DESCRIPTION : Generator Control = PWRP + ECP1 - 100
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W5

=PWRP-W3

=PWRP-W4

=PWRP-W1

=PWRP-W2

CABLE NAME

CABLE NAME
=PWRP+ECP1-X11
TERMINAL STRIP X11 CONTROL PANEL ECP1

RADOX 7x1 mm²

RADOX 3x2,5 mm²

RADOX 3x4 mm²

RADOX 4x25 mm²

RADOX 4x25 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Generator 2x115V 60Hz 30Kw 1 =PWRP+-100G0 L1 1 =PWRP+ECP1-100Q0 1 =PWRP+ECP1/100.0

= 2 =PWRP+-100G0 N 2 =PWRP+ECP1-100Q0 3 =PWRP+ECP1/100.0

= 3 =PWRP+-100G0 L2 3 =PWRP+ECP1-100Q0 5 =PWRP+ECP1/100.0

Main Power Supply To Cabin 1 =PWRP+-SKT1A R1 4 =PWRP+ECP1-100F7 1 =PWRP+ECP1/100.9

= 2 =PWRP+-SKT1A N(S2) 5 =PWRP+ECP1-100B5 7 =PWRP+ECP1/100.9

= 3 =PWRP+-SKT1A T3 6 =PWRP+ECP1-100F7 3 =PWRP+ECP1/100.9

= 4 =PWRP+-SKT1A PE PE =PWRP+ECP1/100.9

SH =PWRP-W1

Auxiliary Power Socket 1 =PWRP+-100X7 1 7 =PWRP+ECP1-100F7 2 =PWRP+ECP1/100.7

= 2 =PWRP+-100X7 PE 8 =PWRP+ECP1-100F7 4 =PWRP+ECP1/100.7

= 3 =PWRP+-100X7 N PE =PWRP+ECP1/100.7

SH =PWRP-W4

Auxiliary Power Socket sp =PWRP+ECP1/100.8

= sp =PWRP+ECP1/100.8

= sp =PWRP+ECP1/100.8

Generator 2x115V 60Hz 30Kw 4 =PWRP+-100G0 PE.. PE =PWRP+ECP1/100.0

SH =PWRP+-100G0

Voltage regulation 3 =PWRP+-100G0 PE. PE =PWRP+ECP1/100.1

SH =PWRP+-100G0

Voltage / Current signals 7 =PWRP+ECP3-X32 PE PE =PWRP+ECP1/100.6

SH =PWRP-W5

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP1#-X11 TERMINAL STRIP X11 CONTROL PANEL = PWRP + ECP1 - 1100
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W5

CABLE NAME

CABLE NAME
=PWRP+ECP1-X12
TERMINAL STRIP X12 CONTROL PANEL ECP1

RADOX 7x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Voltage / Current signals 1 =PWRP+ECP3-X34 30 1 =PWRP+ECP1/100.5

= 2 =PWRP+ECP3-0VDC-E 14 2 =PWRP+ECP1-100T4 =PWRP+ECP1/100.5

= 3 =PWRP+ECP3-X34 11 3 =PWRP+ECP1-100B5 3 =PWRP+ECP1/100.5

= 4 =PWRP+ECP1-100B5 1 =PWRP+ECP1/100.6

= 5 =PWRP+ECP3-X32 19 5 =PWRP+ECP1-100B5 9 =PWRP+ECP1/100.6

= 6 =PWRP+ECP3-X32 20 6 =PWRP+ECP1-100B5 10 =PWRP+ECP1/100.6

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP1#-X12 TERMINAL STRIP X12 CONTROL PANEL = PWRP + ECP1 - 1101
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W3

CABLE NAME

CABLE NAME
=PWRP+ECP1-X14
TERMINAL STRIP X14 CONTROL PANEL ECP1

RADOX 3x2,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Voltage regulation 1 =PWRP+-100G0 F- 1 =PWRP+ECP1-100B0 =PWRP+ECP1/100.1

= 2 =PWRP+-100G0 F+ 2 =PWRP+ECP1-100B0 =PWRP+ECP1/100.1

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +ECP3/1a

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP1#-X14 TERMINAL STRIP X14 CONTROL PANEL = PWRP + ECP1 - 1102
0 1 2 3 4 5 6 7 8 9

Powerpack

ECP3 = PWRP 24V CAT6.6 IFM ATX


8501035867

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP1/1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 200

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 09.Jul.2014 PAGE DESCRIPTION : Frontpage = PWRP + ECP3 - 1a
0 1 2 3 4 5 6 7 8 9

+24VDC
+-ECP3 X200F0
PP+24V / 201.0
8501035867 1 2 3 2
PP-0V / 201.0
1 0VDC 3
E

-200F0 1 1+ -200F8 1 -200F9 1


24VDC 24VDC 24VDC ECP1
Alternator
200D2 -200K5 Safety Powerpack
32A 1N5408 2 /200.4 Valve 4A
Ex nA 2- 2 2
Ex de 8A Ex de
A1085720 A1080309 Ex de A1085712
A1079006 A1085716 A1079006
A1079006

-200F6 1
-200R1 -200H2

302.3 / 24V+
13 12 14
200 Ohm DYNAMO -302S5 -200K6 24VDC ECP2
Ex nA LIGHT /302.5 /200.5 Cabin
A1065792 24/230V 14 11 25A
2
Ex d Ex de
A1048931 A1085719
A0011041 A1079006

12 14 22 24
-305K3
/305.3
11 21

3 4 1 3 3 4 1 3
-200D0 -200D1 -200D3 -200D3.1
2x 60A 45V 2x 60A 45V 2x 60A 45V 2x 60A 45V
Ex nA 1 2 2 4 Ex nA Ex nA 1 2 2 4 Ex nA
A1066383 A1066383 A1066383 A1066383

ALT / 303.7 3 A1
-200K5 -200K6
Ex nA 4 24V 6A A2
A1080373 Ex nC
A1060263

14 11 /200.5
1+ 2- /200.6 12
24 21
PE PE PE PE 22 PE PE

IS-Earth
53 54 55 56 PE 57 58 59 60 PE SP SP SP SP SP SP SP PE
X32 1 2 3 4 52 X32 5 6 7 8 X32 9 9 10 10 11 12 X32 13 14 15 16 17 18 X32 19 20 21
Ex e Ex e
W7 BK W9 BK IS-ECP3 bk/ye W10 1 2 3 4

WH-C2

GN/YE
BN-C2

GY-C3

PK-C3

WH-E
OG-E

BU-E
YE-E
+/20.5 +/20.5 +/20.6 +/20.4
10 W11 M1 M2 M3 M4 M5 M6 S2 S3 S4 S5 S6 S7 S8
1 3 +/20.4
W6 1 2 3 4 5
+/20.4
+-EJB9
-200S1 2
9 4 8501036543

Main Switch
(Battery)
A1061325 earth XB + - +/20.4 + + - - PE
/200.4 /300.9
+/20.5 A1100399 1 2 3 4
W8 BK IS PLG6 SKT2 R P H G M L I F D N S J E K O U W X X V T
+/20.5 +/20.6

+-EJB8

+-SP1
+ECP1/100.6

+-SP2
+ECP1/100.6

+-PE
+ECP1/100.6
A1054425
B+ 0V D+ W SP X82 1+ 2-
35 mm²

35 mm²

WB1 BK BK WB2 gn/ye WB3


-200G0 +/20.5 +/20.5 +/20.5 Connections to: Connections to:
24VDC 25A CAB+ECP2 CAB+ECP2
EX + - page 101 page 101
A1033192
+/20.4 PE

-200B1
24V 65Ah
Alternator A1044994 Auxileary Enable 24VDC
Battery Dynamo Cabin 24VDC /
Light Supply Start Engine

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1a PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 201

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD Ronald Bos 15.Jan.2015 PAGE DESCRIPTION : Control Circuit Generator Control = PWRP + ECP3 - 200
0 1 2 3 4 5 6 7 8 9

200.9 / PP+24V PP+24V / 300.0


200.9 / PP-0V PP-0V / 300.0

-201F1 1 -201F4 1 -201F5 1


Engine Portable Mastdrive
ECU Light 2A
32A 24VDC Ex de
2 2 2
Ex de 2A A1085707
A1085720 A1085707 A1079006
A1079006 A1079006

-201S5 13
CANH Activate
300.4 Mastdrive
CANL A0021204 14
300.4 A1059770

-201U3
10nF EMC
FILTER
ATX

56 Ohm

56 Ohm
6501062625

1 2 pe

PE
ENBL.ENGINE / 305.2

TRTL / 302.1

5V / 302.1

A1+ A1 A1+

PE -201K5 -201K6 -201K7


24VDC A2- 24V 6A A2 24VDC A2-
PE
Ex nC Ex nC Ex nC
A1029768 A1060263 A1029768
X32 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 61 62 X32 37 38 X32 39 40 41 42
Ex e Ex e
14 11 /303.3 14 11 /303.4 14 11 /305.7
12 12 12
W12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 W13 24 21
+/20.6
+/20.6 +/20.7
+/20.7 22
/201.0 /201.4
/201.0 A1026144
A1084107 A0020281
Engine ECU 7 8 15 16 1 2 3 9 10 40 20 21 22 53 41 33 1 2
SKT9
P1 sp sp
PLG9
A0019513
+/20.6 A0019134 1 2
C1 8501034376 A1026145
/201.0 7 8 15 16 1 2 3 9 10 40 20 21 22 53 41 33 +/20.7
-201U3 /201.4

C2
PWM Throttle
IGN. Switch

18 20 21 23 24 45
Battery (+)

Battery (+)

Battery (+)

Battery (+)

Sens.Supp.

Sens.Supp.
Battery (-)

Battery (-)

Battery (-)

- Battery

- Battery

Can (+)

Can (-)

Can (-)

W RD OR BK GN YE BU

A E D F G B -201H4
P2 Portable
Light
EX TL 8W
-201U0 24V AC/DC
P1 A1014454
Engine ECU
+/20.6

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
200 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 300

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD Ronald Bos 15.Jan.2015 PAGE DESCRIPTION : Control Circuit Generator Control = PWRP + ECP3 - 201
0 1 2 3 4 5 6 7 8 9

300U0
IFM CR7021
6501052994
A1056781
/301.0 CAN 1 CAN 1 CAN 2 CAN 2
/302.0
VBB s VBB o VBB r GND s GND o GND a GND RxD TxD ERROR TEST H L H L
/303.0
/304.0
/305.0
VBB s 23 VBB o 05 VBB r 34 GND s 01 GND o 15 GND a 12 GND 33 RxD 06 TxD 07 ERROR 13 TEST 24 CAN 1-H 14 CAN 1-L 32 CAN 2-H 26 CAN 2-L 25

SKTC1 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
/300.0
X34 23 05 34 01 15 12 33 06 07 13 24 14 32 26 25
11

-300K4
/300.3 12 14
24V / 300.4 +24VDC
X300F2
TEST INPUT :
1 2 - NORMAL TO GROUND
- FOR SOFTWARE TO +12/24VDC
-300F0 2 -300F1 2 -300F2 2
IFM IFM IFM
VBB s VBB o Circuit
4A 16A 10A
1 1 1 300.0 / 24V
Ex de Ex de Ex de
/300.5
A1085712 A1085715 A1085714 /300.5
A1079006 A1079006 A1079006 Cantrak
1 2 4 4 5 6
PLGA
201.9 / PP+24V
-300P4 A
Ex nAnL
6501052598 1 2 3 4 5 6
A1061630
A1061631

7 8 9 10 11 12

12 14 22 24
PLGA 7 8 -304K6
/304.5
11 21

A2- -300K4 PE
24VDC
201.9 / PP-0V Ex nC -300U8 1 2 pe
4 5 6 7 8 9 29 10 11 A1+ A1029768 EMC

56 Ohm

56 Ohm
0VDC-E 14 11 /300.5 FILTER
12 ATX
6501062625
10nF

201.3 / CANH
201.3 / CANL

PE
A1082717 X32 43 44
A1083957
Interface A B C D E
SKTC2
Ex e Ex e
W11 GN-C1 YE-C1
+/20.4

+EJB9 +/20.4
/304.5
/200.3 /200.6
A1082447
A1068666
A1061894 A B
SKT2

Connections to:
CAN +ECP2 Page 300
Interface
Programming
(RS232) CANBUS
TO
CABIN
THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
201 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 301

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Safety controller EX = PWRP + ECP3 - 300
0 1 2 3 4 5 6 7 8 9

-300U0 INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT


/300.0
Main
Main Control Exhaust Hydraulic Oil Air
Generator Generator Generator
Pressure Pressure Temperature Temperature Pressure
Pressure Voltage Current
4-20mA 4-20mA 4-20mA 4-20mA 4-20mA
4-20mA
IX0.00/IW03 IX0.01/IW04 IX0.02/IW05 IX0.03/IW06 IX0.04/IW07 IX0.05/IW08 IX0.06/IW09 IX0.07/IW10
-AI (4-20mA) 08 -AI (4-20mA) 27 -AI (4-20mA) 09 -AI (4-20mA) 28 -AI (4-20mA) 10 -AI (4-20mA) 29 -AI (0-20mA) 11 -AI (4-20mA) 30

SKTC1 08 27 09 28 10 29 11 30
/300.0
X34 08 27 09 28 10 29 11 30

+24VDC
X300F2

6
0VDC
E
12

Off/On

7+ 9- 1+ 2- 5+ 6- LF1
ADJ1
24V
LF2
10+ 12- 14+ 13- ADJ2

-301U3
9182
Ex nAC
A1065727
+/20.9
+/20.9

PE PE PE IS-Earth IS-Earth PE
+24VDC +24VDC +24VDC +24VDC 0VDC 0VDC
X300F2 X300F2 X300F2 X300F2 E E
3 4 5 7 13 14
Ex e Ex e
W14 1 2 3 W15 1 2 3 W16 1 2 3 1 2 W17 W18 1 2 W19 1 2 3
+/20.7 +/20.8 +/20.8 +/20.9 +/20.9 +/20.10

pe
2
P
1 2
P 1 pe 2
P 1 pe 2
T 3 2
T 3 2
P 1 pe

SIGN3
+ECP1/100.5

SIGN4
+ECP1/100.6

SIGN2
+ECP1/100.5

SIGN1
+ECP1/100.5
-301B1 -301B2 -301B3 -301B4 -301B5 -301B6
EX Zone 2 EX Zone 2 EX Zone 2 PT100 -50..+250ºC PT100 -50..+250ºC EX Zone 2
0-600BAR 60BAR 0-600BAR 4-20mA [6A12.1] [10A2.1] 60BAR 4-20MA
4-20mA 4-20MA A1067640 A1059899 A1059899 A1066387
A1067640 A1066387 A1099135 A1060300 A1060300 A1099135
A1099135 A1099135 +/20.8 +/20.9 +/20.9 +/20.10
+/20.7 +/20.8

Ex ia circuit
Main Control Main Exhaust Hydraulic Oil Air
Pressure Pressure Generator Temperature Temperature Pressure
4-20mA 4-20mA Pressure 4-20mA 4-20mA 4-20mA
4-20mA

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
300 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 302

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Safety controller = PWRP + ECP3 - 301
0 1 2 3 4 5 6 7 8 9

-300U0 OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT


/300.0

Throttle Fan Pull Hold Start Stop Emergency Generator


Control Speed Safety Safety Engine Engine Stop Frequency
Valve Valve
IX0.08/QX0.00 IX0.09/QX0.01 IX0.10/QX0.02 IX0.11/QX0.03 IX0.12 IX0.13 IX0.14 IX0.15
-PWM 44 -PWM 45 -DO 46 -DO 47 -DI 20 -DI 02 -DI 21 -FI 38

SKTC1 44 45 46 47 20 02 21 38
/300.0
X34 44 45 46 47 20 02 21 38

0VDC +24VDC +24VDC +24VDC +24VDC


E X300F2 X300F2 X300F2 X300F2

15 8 9 10 12

1+
-302U1 -302K3 +3 13 21 21
-302U8
-A2 1 +A1 3
Ex n
Ex nA -302S5 -302S6 -302S7 Ex n
A1064771 2- Start Stop E.M. Stop A1064771
+A1 3 A1080373 -A2 1
Engine Engine A1059770

/302.3
-4 14 22 22
A1026946 A1059770 A0021203
A0021202 A0021202
17 /200.4 19

E E
0VDC 0VDC
5V
201.3

201.3 / TRTL

200.8
24V+

1+
-302K3
/302.3 2-

0VDC
E +24VDC
X300F2
16
PE PE 0VDC PE
11 E
0VDC
E 20
X32 45 X32 46 47 63
18
Ex e Ex e
W20 1 2 W21 BU GN/YE BN W22 1 2 3 4 5 6
+/20.10 +/20.11 +/20.12

+ -
+-EJB17 X172 1 2 3 4 5 PE
A1070273
-Y1 -Y2
W23 RD BK BN BU GN
Valve Pull Valve Hold
+/20.12
-302Y2 Solenoid 25A Solenoid 0.5A
19CC
A1099133 +V GND D SIGN sp
+/20.10 -302Y3
ATEX EEx e I
Air-inlet Valve
A1033195 -302S8
+/20.11 5-32Vdc
Speedsensor
Generator
6501048420
+/20.11
Pull
Safety Generator
Valve Frequency

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
301 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 303

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Safety controller = PWRP + ECP3 - 302
0 1 2 3 4 5 6 7 8 9

300U0 OUTPUT OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT INPUT


/300.0

Pumpmotor Relief Valve Winchpump Winchpump Start Stop Alternator Shutdown


Generator Drum Out Hole In Hole Generator Generator Signal
Displacment
QX0.04 QX0.05 QX0.06 QX0.07 IX1.04 IX1.05 IX1.06 IX1.07
-PWM 36 -PWM 54 -PWM 17 -PWM 53 -DI 19 -DI 55 -FI 18 -DI 37

SKTC1 36 54 17 53 19 55 18 37
/300.0
X34 36 54 17 53 19 55 18 37

+24VDC +24VDC +24VDC


ALT
X300F2 X300F2 X300F2
200.2
13 14 15

Off/On

13 21
LF1 2 3 1 -303U8
12 14 12 14 INV1 9170/20-10-11K
-303S5 -303S6 A1080113
-201K5 -201K6 Start Stop LF2
/201.5 /201.6 Generator 14 Generator 22 INV2 + - 10+ 11-
11 11
A1059770 A1059770
A0021202 A0021202
25

E
0VDC

0VDC 0VDC 0VDC 0VDC


E PE E PE E PE E PE IS-Earth IS-Earth IS-Earth

21 22 23 24
X38 1 2
X32 48 X32 49
Ex e Ex e
SH SH SH SH W29a
+/20.15
W28 1 2 /303.8 1+/20.15 2 W30 1 2
W24 2 1 3 W25 2 1 3 W26 2 1 3 W27 2 1 3 +/20.14 A1055546 +/20.15
+/20.12 +/20.13 +/20.13 +/20.14 A1056235
A1056238
SKT11 1 2

PLG11
- + PE - + PE - + PE - + PE A1056235 1 2
2 1 pe 2 1 pe 2 1 pe 2 1 pe A1058936
A1055544

W29 1 2
+/20.15

-303Y1 -303Y2 -303Y3 -303Y4 1


1
3
11 11
-10P2.1 -10M9.1 -10P3 -10P3
56cc/15cc 24VDC 24VDC (EP2) 24VDC (EP2) P
24 VDC A1099133 A0020417 A0020417 3 12 12
SAE-C/- +/20.13 A1099133 A1099133
A1072900 +/20.13 +/20.14
-303B8 -303S8 -303S9
A1099133 Exhaust Coolant
+/20.12
Oil
Pressure Temp. Temp.
2 bar 200°C 100°C
A1109848 6A13 6A13.1
Generator Relief Valve Winchpump Winchpump +/20.14 6501065098 6501063072
+/20.15 +/20.15
pump Drum Out Hole In Hole
Ex ia circuit
THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
302 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 304

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Safety controller = PWRP + ECP3 - 303
0 1 2 3 4 5 6 7 8 9

300U0 INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT


/300.0

Low Low Low


Throttle Throttle Cabin
Hydraulic Oil Fuel Level Coolant Spare Spare
Up Down Connected
Level Too Low Spare Level
IX1.08/QX0.08 IX1.09/QX0.09 IX1.10/QX0.10 IX1.11/QX0.11 IX1.12/QX0.12 IX1.13/QX0.13 IX1.14/QX0.14 IX1.15/QX0.15
-DI 39 -DI 03 -DI 40 -DI 22 -DI 41 -DI 42 -DI/DO 43 -DI/DO 04

SKTC1 39 03 40 22 41 42 43 04
/300.0
X34 39 03 40 22 41 42 43 04

A1
-304K6
24V 6A
A2 Ex nC
26
A1060263

E
0VDC
-304S3
Throttle 14 11 /300.8
BK BU
Up/Down 12
A1026946 S1 S1 24 21 /300.8
A1040349 GY BN 22

17 18 19

+24VDC +24VDC +24VDC


X300F2 X300F2 X300F2

PE PE
+24VDC +24VDC
X300F2 X300F2
X32 50
16 20
Ex e Ex e
W31 1 2 W11 S1 W32 1 2
+/20.16 +/20.4 +/20.16

11 11 12 11 11 12

12 12

-304S1 -304S6
Low Hydr. Low
Oil Level +EJB9 /300.9 Coolant
A1066393 /200.3 SKT2 C Level
+/20.16 A1066393
+/20.16

Low Low Low


Hydraulic Oil Fuel Level Coolant
Level Too Low Spare Level

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
303 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 305

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Safety controller = PWRP + ECP3 - 304
0 1 2 3 4 5 6 7 8 9

300U0 OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT


/300.0

Hydraulic Fan
Start Enable Undervoltage Enable
Off/On Spare Spare Spare
Engine Engine Shutoff Manifold
Spare
QX1.00 QX1.01 QX1.02 QX1.03 QX1.04 QX1.05 QX1.06 QX1.07
-DO 48 -DO 49 -DO 31 -DO/AO 50 -DO/AO 51 -DO 52 -DO 16 -DO/AO 35

SKTC1 48 49 31 50 51 52 16 35
/300.0
X34 48 49 31 50 51 52 16 35

14 11 /200.4
-305K3 A1
12
24V 6A 24 21 /200.5
Ex nC 22
A2
A1060263

28

E
0VDC

12 14
-201K7
/201.7
Activate 11

201.2 / ENBL.ENGINE
Breaker

0VDC
E
27
PE

X32 51
Ex e Ex e
W33 BN BU GN/YE
+/20.17

+ - PE

-305Y1
10V12
1/8"
A0001942
A0011352

Start Enable Undervoltage Hydraulic Fan Enable Servo 2 4/2 Valve Winch shutdown
Engine Engine Shutoff Off/On Manifold Relief (shutdown valve)
Spare

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
304 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 306

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Safety controller = PWRP + ECP3 - 305
0 1 2 3 4 5 6 7 8 9

SAFETY CONTROLLER
=PWRP+ECP3-300U0 =PWRP+ECP3-300U0
23
-VBB s /300.0 VBB s
05
-VBB o /300.1 VBB o
34
-VBB r /300.1 VBB r
01
-GND s /300.2 GND s
15
-GND o /300.2 GND o
12
-GND a /300.3 GND a
33
-GND /300.3 GND
06
-R x D /300.4 RxD
07 36
-T x D /300.4 TxD -QX0.04-PWM /303.1 Pumpmotor Generator Displacment
13 54
-ERROR /300.5 ERROR -QX0.05-PWM /303.2 Relief Valve Drum
24 17
-TEST /300.5 TEST -QX0.06-PWM /303.3 Winchpump Out Hole
53
14 -QX0.07-PWM /303.4 Winchpump In Hole
-CAN1-H /300.7 CAN 1 H 19
32 -IX1.04-DI /303.5 Start Generator
-CAN1-L /300.7 CAN 1 L 55
26 -IX1.05-DI /303.6 Stop Generator
-CAN2-H /300.8 CAN 2 H 18
25 -IX1.06-FI /303.7 Alternator Signal
-CAN2-L /300.8 CAN 2 L 37
-IX1.07-DI /303.8 Shutdown

08 39
-IX0.00/IW03-AI(4-20mA) /301.1 Main Pressure 4-20mA -IX1.08/QX0.08-DI /304.1 Low Hydraulic Oil Level Too Low
27 03
-IX0.01/IW04-AI(4-20mA) /301.2 Control Pressure 4-20mA -IX1.09/QX0.09-DI /304.2 Low Fuel Level Spare
09 40
-IX0.02/IW05-AI(4-20mA) /301.3 Main Generator Pressure 4-20mA -IX1.10/QX0.10-DI /304.3 Throttle Up
28 22
-IX0.03/IW06-AI(4-20mA) /301.4 Exhaust Temperature 4-20mA -IX1.11/QX0.11-DI /304.4 Throttle Down
10 41
-IX0.04/IW07-AI(4-20mA) /301.5 Hydraulic Oil Temperature 4-20mA -IX1.12/QX0.12-DI /304.5 Cabin Connected
29 42
-IX0.05/IW08-AI(4-20mA) /301.6 Air Pressure 4-20mA -IX1.13/QX0.13-DI /304.6 Low Coolant Level
11 43
-IX0.06/IW09-AI(0-20mA) /301.7 Generator Voltage -IX1.14/QX0.14-DI/DO /304.7 Spare
30 04
-IX0.07/IW10-AI(4-20mA) /301.8 Generator Current -IX1.15/QX0.15-DI/DO /304.8 Spare

44 48
-IX0.08/QX0.00-PWM /302.1 Throttle Control -QX1.00-DO /305.1 Start Engine
45 49
-IX0.09/QX0.01-PWM /302.2 Fan Speed -QX1.01-DO /305.2 Enable Engine
46 31
-IX0.10/QX0.02-DO /302.3 Pull Safety Valve -QX1.02-DO /305.3 Undervoltage Shutoff
47 50
-IX0.11/QX0.03-DO /302.4 Hold Safety Valve -QX1.03-DO/AO /305.4 Hydraulic Fan Off/On Spare
20 51
-IX0.12-DI /302.5 Start Engine -QX1.04-DO/AO /305.5 Spare
02 52
-IX0.13-DI /302.6 Stop Engine -QX1.05-DO /305.6 Spare
21 16
-IX0.14-DI /302.7 Emergency Stop -QX1.06-DO /305.7 Enable Manifold
38 35
-IX0.15-FI /302.8 Generator Frequency -QX1.07-DO/AO /305.8 Spare

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
305 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Controller Overview = PWRP + ECP3 - 306
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W27

=PWRP-W26

=PWRP-W25

=PWRP-W24

=PWRP-W22

=PWRP-W21

=PWRP-W20

=PWRP-W5

CABLE NAME

CABLE NAME
=PWRP+ECP3-0VDC-E
TERMINAL STRIP 0VDC-E CONTROL PANEL ECP3 (0VDC)

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 6x0,5 mm²

Molded-a3 3x1,5 mm²

RADOX 2x1,5 mm²

RADOX 7x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Enable 24VDC / Start Engine 1 =PWRP+ECP3-200D3.1 1 =PWRP+ECP3/200.5

= 2 =PWRP+ECP3-200K6 A2 =PWRP+ECP3/200.5

= 3 =PWRP+ECP3-X32 16 =PWRP+ECP3/200.6

VBB r 4 =PWRP+ECP3-X32 40 =PWRP+ECP3/300.2

GND s 5 =PWRP+ECP3-X34 01 =PWRP+ECP3/300.2

= 6 =PWRP+ECP3-X34 15 =PWRP+ECP3/300.2

= 7 =PWRP+ECP3-X34 12 =PWRP+ECP3/300.2

= 8 =PWRP+ECP3-X34 33 =PWRP+ECP3/300.2

= 9 =PWRP+ECP3-300K4 12 =PWRP+ECP3/300.2

GND o 29 =PWRP+ECP3-PLGA 1 =PWRP+ECP3/300.2

= 10 =PWRP+ECP3-300K4 A2- =PWRP+ECP3/300.2

= 11 =PWRP+ECP3-SKTC2 C =PWRP+ECP3/300.2

Exhaust Temperature 4-20mA 12 =PWRP+ECP3-301U3 9- =PWRP+ECP3/301.4

Generator Voltage 13 =PWRP+ECP3/301.7

= 2 =PWRP+ECP1-X12 2 14 =PWRP+ECP3/301.8

15 =PWRP+ECP3-302U1 -A2 =PWRP+ECP3/302.1

Fan Speed 2 =PWRP+-302Y2 - 16 =PWRP+ECP3/302.2

Pull Safety Valve 17 =PWRP+ECP3-302K3 -4 =PWRP+ECP3/302.3

= BU =PWRP+-302Y3 18 =PWRP+ECP3/302.3

Emergency Stop 19 =PWRP+ECP3-302U8 -A2 =PWRP+ECP3/302.8

= 2 =PWRP+EJB17-X172 2 20 =PWRP+ECP3/302.8

Generator pump 2 =PWRP+-303Y1 - 21 =PWRP+ECP3/303.1

Relief Valve Drum 2 =PWRP+-303Y2 - 22 =PWRP+ECP3/303.2

Winchpump Out Hole 2 =PWRP+-303Y3 - 23 =PWRP+ECP3/303.3

Winchpump In Hole 2 =PWRP+-303Y4 - 24 =PWRP+ECP3/303.4

Alternator Signal 25 =PWRP+ECP3-303U8 - =PWRP+ECP3/303.8

Cabin Connected 26 =PWRP+ECP3-304K6 A2 =PWRP+ECP3/304.5

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
306 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1101

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-0VDC-E TERMINAL STRIP 0VDC-E CONTROL = PWRP + ECP3 - 1100
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W33

CABLE NAME

CABLE NAME
=PWRP+ECP3-0VDC-E
TERMINAL STRIP 0VDC-E CONTROL PANEL ECP3 (0VDC)

Molded-a3 3x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Start Engine BU =PWRP+-305Y1 - 27 =PWRP+ECP3/305.1

Undervoltage Shutoff 28 =PWRP+ECP3-305K3 A2 =PWRP+ECP3/305.3

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1102

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-0VDC-E TERMINAL STRIP 0VDC-E CONTROL = PWRP + ECP3 - 1101
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W11

=PWRP-W10

=PWRP-W9

=PWRP-W7

=PWRP-W6

CABLE NAME

CABLE NAME
=PWRP+ECP3-X32
TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

SABIX-Multi 25xSpcl mm²

RADOX 4x6 mm²

GEXOL 1x8 AWG

GEXOL 1x8 AWG

RADOX 5x2,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Alternator 1 =PWRP+-200G0 B+ 1 =PWRP+ECP3-200D0 1 =PWRP+ECP3/200.0

= 2 =PWRP+-200G0 0V 2 =PWRP+ECP3-200D1 2 =PWRP+ECP3/200.0

= 3 =PWRP+-200G0 D+ 3 =PWRP+ECP3-200R1 =PWRP+ECP3/200.0

= 4 =PWRP+-200G0 W 4 =PWRP+ECP3-X34 18 =PWRP+ECP3/200.1

= 5 =PWRP+-200G0 SP 52 =PWRP+ECP3/200.1

= SH =PWRP-W6 SH PE =PWRP+ECP3/200.1

Battery BK =PWRP+-200S1 1 5 =PWRP+ECP3-X32 1 =PWRP+ECP3/200.1

= BK =PWRP+EJB8-X82 2- 6 =PWRP+ECP3-X32 2 =PWRP+ECP3/200.2

Dynamo Light 7 =PWRP+ECP3/200.2

= PE =PWRP+ECP3/200.2

= 8 =PWRP+ECP3/200.2

Auxileary Cabin 24VDC Supply 1 =PWRP+EJB9-XB + 9 =PWRP+ECP3-200D3 1 =PWRP+ECP3/200.3

= 2 =PWRP+EJB9-XB + 9 =PWRP+ECP3/200.3

= 3 =PWRP+EJB9-XB - 10 =PWRP+ECP3-200D3.1 2 =PWRP+ECP3/200.3

= 4 =PWRP+EJB9-XB - 10 =PWRP+ECP3/200.4

= SH =PWRP+EJB9-XB PE PE =PWRP+ECP3/200.4

= 11 =PWRP+ECP3/200.4

= PE =PWRP+ECP3/200.4

= 12 =PWRP+ECP3/200.4

Enable 24VDC / Start Engine M1 =PWRP+EJB9-SKT2 13 =PWRP+ECP3/200.6

= M2 =PWRP+EJB9-SKT2 14 =PWRP+ECP3/200.6

= M3 =PWRP+EJB9-SKT2 15 =PWRP+ECP3-200F6 2 =PWRP+ECP3/200.6

= M4 =PWRP+EJB9-SKT2 P 16 =PWRP+ECP3-0VDC-E 3 =PWRP+ECP3/200.6

= M5 =PWRP+EJB9-SKT2 P 17 =PWRP+ECP3/200.6

= M6 =PWRP+EJB9-SKT2 P 18 =PWRP+ECP3/200.6

= BN-C2 =PWRP+EJB9-SKT2 H 53 =PWRP+ECP3/200.7

= WH-C2 =PWRP+EJB9-SKT2 G 54 =PWRP+ECP3/200.7

= GY-C3 =PWRP+EJB9-SKT2 M 55 =PWRP+ECP3/200.7

= PK-C3 =PWRP+EJB9-SKT2 L 56 =PWRP+ECP3/200.7

= PE =PWRP+ECP3/200.7

= YE-E =PWRP+EJB9-SKT2 F 57 =PWRP+ECP3/200.7

= OG-E =PWRP+EJB9-SKT2 D 58 =PWRP+ECP3/200.7

= WH-E =PWRP+EJB9-SKT2 N 59 =PWRP+ECP3/200.7

= BU-E =PWRP+EJB9-SKT2 S 60 =PWRP+ECP3/200.7

= SH =PWRP+EJB9-SKT2 I PE =PWRP+ECP3/200.7

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1101 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1103

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X32 TERMINAL STRIP X22 CONTROL PANEL = PWRP + ECP3 - 1102
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W13

=PWRP-W12

=PWRP-W5

=PWRP-W11

CABLE NAME

CABLE NAME
=PWRP+ECP3-X32
TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

RADOX 2x1,5 mm²

RADOX 18x1 mm²

RADOX 7x1 mm²

SABIX-Multi 25xSpcl mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Enable 24VDC / Start Engine S2 =PWRP+EJB9-SKT2 E SP =PWRP+ECP3/200.8

= S3 =PWRP+EJB9-SKT2 K SP =PWRP+ECP3/200.8

= S4 =PWRP+EJB9-SKT2 O SP =PWRP+ECP3/200.8

= S5 =PWRP+EJB9-SKT2 U SP =PWRP+ECP3/200.8

= S6 =PWRP+EJB9-SKT2 W SP =PWRP+ECP3/200.8

= S7 =PWRP+EJB9-SKT2 X SP =PWRP+ECP3/200.8

= S8 =PWRP+EJB9-SKT2 X SP =PWRP+ECP3/200.8

= PE =PWRP+ECP3-X32 PE =PWRP+ECP3/200.8

= GN/YE =PWRP+EJB9-SKT2 T PE =PWRP+ECP3/200.8

=PWRP+ECP3-X32

Enable 24VDC / Start Engine 5 =PWRP+ECP1-X12 5 19 =PWRP+ECP3-200F9 2 =PWRP+ECP3/200.9

= 6 =PWRP+ECP1-X12 6 20 =PWRP+ECP3-X32 16 =PWRP+ECP3/200.9

= 7 =PWRP+ECP1-X11 PE PE =PWRP+ECP3/200.9

= 21 =PWRP+ECP3/200.9

1 =PWRP+-P1 7 22 =PWRP+ECP3/201.0

2 =PWRP+-P1 8 23 =PWRP+ECP3/201.0

3 =PWRP+-P1 15 24 =PWRP+ECP3/201.1

4 =PWRP+-P1 16 25 =PWRP+ECP3-201F1 2 =PWRP+ECP3/201.1

5 =PWRP+-P1 1 26 =PWRP+ECP3-X32 20 =PWRP+ECP3/201.1

6 =PWRP+-P1 2 27 =PWRP+ECP3/201.1

7 =PWRP+-P1 3 28 =PWRP+ECP3/201.1

8 =PWRP+-P1 9 29 =PWRP+ECP3/201.2

9 =PWRP+-P1 10 30 =PWRP+ECP3/201.2

16 =PWRP+-P1

10 =PWRP+-P1 40 31 =PWRP+ECP3-X34 49 =PWRP+ECP3/201.2

11 =PWRP+-P1 20 32 =PWRP+ECP3-PLGA 8 =PWRP+ECP3/201.2

12 =PWRP+-P1 21 33 =PWRP+ECP3-PLGA 7 =PWRP+ECP3/201.2

13 =PWRP+-P1 22 34 =PWRP+ECP3/201.3

14 =PWRP+-P1 53 35 =PWRP+ECP3-302U1 3 =PWRP+ECP3/201.3

15 =PWRP+-P1 41 36 =PWRP+ECP3-302U1 +A1 =PWRP+ECP3/201.3

17 =PWRP+-P1 sp 61 =PWRP+ECP3/201.3

18 =PWRP+-P1 sp 62 =PWRP+ECP3/201.3

SH =PWRP-W12 SH PE =PWRP+ECP3/201.4

1 =PWRP+-SKT9 1 37 =PWRP+ECP3-201F4 2 =PWRP+ECP3/201.4

2 =PWRP+-SKT9 2 38 =PWRP+ECP3-201K7 A2- =PWRP+ECP3/201.5

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1102 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1104

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X32 TERMINAL STRIP X22 CONTROL PANEL = PWRP + ECP3 - 1103
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W27

=PWRP-W26

=PWRP-W22

=PWRP-W21

=PWRP-W11

=PWRP-W13

CABLE NAME

CABLE NAME
=PWRP+ECP3-X32
TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 6x0,5 mm²

Molded-a3 3x1,5 mm²

SABIX-Multi 25xSpcl mm²

RADOX 2x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

SH =PWRP-W13 SH PE =PWRP+ECP3/201.5

CANBUS TO CABIN PE =PWRP+ECP3/300.9

39 =PWRP+ECP3-201K5 A1+ =PWRP+ECP3/201.8

40 =PWRP+ECP3-201K7 A2- =PWRP+ECP3/201.8

41 =PWRP+ECP3-X32 39 =PWRP+ECP3/201.9

42 =PWRP+ECP3-X32 40 =PWRP+ECP3/201.9

CAN 2 L GN-C1 =PWRP+EJB9-SKT2 A 43 =PWRP+ECP3-X34 26 =PWRP+ECP3/300.9

CANBUS TO CABIN YE-C1 =PWRP+EJB9-SKT2 B 44 =PWRP+ECP3-X34 25 =PWRP+ECP3/300.9

Pull Safety Valve GN/YE =PWRP+-302Y3 45 =PWRP+ECP3-302K3 2- =PWRP+ECP3/302.3

Hold Safety Valve SH =PWRP-W21 SH PE =PWRP+ECP3/302.4

Generator Frequency 3 =PWRP+EJB17-X172 3 46 =PWRP+ECP3/302.8

= 4 =PWRP+EJB17-X172 4 47 =PWRP+ECP3-302U8 1 =PWRP+ECP3/302.8

= 5 =PWRP+EJB17-X172 5 63 =PWRP+ECP3/302.8

Winchpump Out Hole 1 =PWRP+-303Y3 + 48 =PWRP+ECP3-201K5 11 =PWRP+ECP3/303.3

= 3 =PWRP+-303Y3 PE PE =PWRP+ECP3/303.3

SH =PWRP-W26

Winchpump In Hole 1 =PWRP+-303Y4 + 49 =PWRP+ECP3-201K6 11 =PWRP+ECP3/303.4

= 3 =PWRP+-303Y4 PE PE =PWRP+ECP3/303.4

SH =PWRP-W27

Cabin Connected S1 =PWRP+EJB9-SKT2 C 50 =PWRP+ECP3-X34 41 =PWRP+ECP3/304.5

4/2 Valve Relief 51 =PWRP+ECP3-201K7 11 =PWRP+ECP3/305.7

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1103 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1105

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X32 TERMINAL STRIP X22 CONTROL PANEL = PWRP + ECP3 - 1104
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W5

=PWRP-W19

=PWRP-W16

=PWRP-W15

=PWRP-W14

CABLE NAME

CABLE NAME
=PWRP+ECP3-X34
TERMINAL STRIP X34 CONTROL PANEL ECP3

RADOX 7x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

VBB s =PWRP+ECP3-300F0 2 23 =PWRP+ECP3-SKTC1 23 =PWRP+ECP3/300.0

VBB o =PWRP+ECP3-300F1 2 05 =PWRP+ECP3-SKTC1 05 =PWRP+ECP3/300.1

VBB r 34 =PWRP+ECP3-SKTC1 34 =PWRP+ECP3/300.1

GND s =PWRP+ECP3-0VDC-E 5 01 =PWRP+ECP3-SKTC1 01 =PWRP+ECP3/300.2

GND o =PWRP+ECP3-0VDC-E 6 15 =PWRP+ECP3-SKTC1 15 =PWRP+ECP3/300.2

GND a =PWRP+ECP3-0VDC-E 7 12 =PWRP+ECP3-SKTC1 12 =PWRP+ECP3/300.3

GND =PWRP+ECP3-0VDC-E 8 33 =PWRP+ECP3-SKTC1 33 =PWRP+ECP3/300.3

RxD =PWRP+ECP3-SKTC2 A 06 =PWRP+ECP3-SKTC1 06 =PWRP+ECP3/300.4

TxD =PWRP+ECP3-SKTC2 B 07 =PWRP+ECP3-SKTC1 07 =PWRP+ECP3/300.4

ERROR 13 =PWRP+ECP3-SKTC1 13 =PWRP+ECP3/300.5

TEST =PWRP+ECP3-300K4 11 24 =PWRP+ECP3-SKTC1 24 =PWRP+ECP3/300.5

CAN 1 H =PWRP+ECP3-PLGA 8 14 =PWRP+ECP3-SKTC1 14 =PWRP+ECP3/300.7

=PWRP+ECP3-X34

CAN 1 L =PWRP+ECP3-PLGA 7 32 =PWRP+ECP3-SKTC1 32 =PWRP+ECP3/300.7

=PWRP+ECP3-X34

CAN 2 H =PWRP+ECP3-X32 43 26 =PWRP+ECP3-SKTC1 26 =PWRP+ECP3/300.8

=PWRP+ECP3-X34

CAN 2 L =PWRP+ECP3-X32 44 25 =PWRP+ECP3-SKTC1 25 =PWRP+ECP3/300.8

=PWRP+ECP3-X34

Main Pressure 4-20mA 2 =PWRP+-301B1 1 08 =PWRP+ECP3-SKTC1 08 =PWRP+ECP3/301.1

= 3 =PWRP+-301B1 pe PE =PWRP+ECP3/301.1

SH =PWRP-W14

Control Pressure 4-20mA 2 =PWRP+-301B2 1 27 =PWRP+ECP3-SKTC1 27 =PWRP+ECP3/301.2

= 3 =PWRP+-301B2 pe PE =PWRP+ECP3/301.2

SH =PWRP-W15

Main Generator Pressure 4-20mA 2 =PWRP+-301B3 1 09 =PWRP+ECP3-SKTC1 09 =PWRP+ECP3/301.3

= 3 =PWRP+-301B3 pe PE =PWRP+ECP3/301.3

SH =PWRP-W16

Exhaust Temperature 4-20mA =PWRP+ECP3-301U3 1+ 28 =PWRP+ECP3-SKTC1 28 =PWRP+ECP3/301.4

Hydraulic Oil Temperature 4-20mA =PWRP+ECP3-301U3 5+ 10 =PWRP+ECP3-SKTC1 10 =PWRP+ECP3/301.5

Air Pressure 4-20mA 2 =PWRP+-301B6 1 29 =PWRP+ECP3-SKTC1 29 =PWRP+ECP3/301.6

= 3 =PWRP+-301B6 pe PE =PWRP+ECP3/301.6

SH =PWRP-W19

Generator Voltage 3 =PWRP+ECP1-X12 3 11 =PWRP+ECP3-SKTC1 11 =PWRP+ECP3/301.7

Generator Current 1 =PWRP+ECP1-X12 1 30 =PWRP+ECP3-SKTC1 30 =PWRP+ECP3/301.8

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1104 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1106

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X34 TERMINAL STRIP X34 CONTROL PANEL = PWRP + ECP3 - 1105
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W33

=PWRP-W32

=PWRP-W31

=PWRP-W25

=PWRP-W24

=PWRP-W22

=PWRP-W21

=PWRP-W20

CABLE NAME

CABLE NAME
=PWRP+ECP3-X34
TERMINAL STRIP X34 CONTROL PANEL ECP3

Molded-a3 3x1,5 mm²

RADOX 2x1,5 mm²

RADOX 2x1,5 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 6x0,5 mm²

Molded-a3 3x1,5 mm²

RADOX 2x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Throttle Control =PWRP+ECP3-302U1 1 44 =PWRP+ECP3-SKTC1 44 =PWRP+ECP3/302.1

Fan Speed 1 =PWRP+-302Y2 + 45 =PWRP+ECP3-SKTC1 45 =PWRP+ECP3/302.2

= SH =PWRP-W20 SH PE =PWRP+ECP3/302.2

Pull Safety Valve =PWRP+ECP3-302K3 +3 46 =PWRP+ECP3-SKTC1 46 =PWRP+ECP3/302.3

Hold Safety Valve BN =PWRP+-302Y3 47 =PWRP+ECP3-SKTC1 47 =PWRP+ECP3/302.4

Start Engine =PWRP+ECP3-302S5 14 20 =PWRP+ECP3-SKTC1 20 =PWRP+ECP3/302.5

Stop Engine =PWRP+ECP3-302S6 22 02 =PWRP+ECP3-SKTC1 02 =PWRP+ECP3/302.6

Emergency Stop =PWRP+ECP3-302S7 22 21 =PWRP+ECP3-SKTC1 21 =PWRP+ECP3/302.7

Generator Frequency =PWRP+ECP3-302U8 3 38 =PWRP+ECP3-SKTC1 38 =PWRP+ECP3/302.8

= 6 =PWRP+EJB17-X172 PE PE =PWRP+ECP3/302.8

SH =PWRP-W22

Pumpmotor Generator Displacment 1 =PWRP+-303Y1 + 36 =PWRP+ECP3-SKTC1 36 =PWRP+ECP3/303.1

= 3 =PWRP+-303Y1 PE PE =PWRP+ECP3/303.1

SH =PWRP-W24

Relief Valve Drum 1 =PWRP+-303Y2 + 54 =PWRP+ECP3-SKTC1 54 =PWRP+ECP3/303.2

= 3 =PWRP+-303Y2 PE PE =PWRP+ECP3/303.2

SH =PWRP-W25

Winchpump Out Hole =PWRP+ECP3-201K5 12 17 =PWRP+ECP3-SKTC1 17 =PWRP+ECP3/303.3

Winchpump In Hole =PWRP+ECP3-201K6 12 53 =PWRP+ECP3-SKTC1 53 =PWRP+ECP3/303.4

Start Generator =PWRP+ECP3-303S5 14 19 =PWRP+ECP3-SKTC1 19 =PWRP+ECP3/303.5

Stop Generator =PWRP+ECP3-303S6 22 55 =PWRP+ECP3-SKTC1 55 =PWRP+ECP3/303.6

Alternator Signal =PWRP+ECP3-X32 4 18 =PWRP+ECP3-SKTC1 18 =PWRP+ECP3/303.7

Shutdown =PWRP+ECP3-303U8 3 37 =PWRP+ECP3-SKTC1 37 =PWRP+ECP3/303.8

Low Hydraulic Oil Level Too Low 2 =PWRP+-304S1 12 39 =PWRP+ECP3-SKTC1 39 =PWRP+ECP3/304.1

= SH =PWRP-W31 SH PE =PWRP+ECP3/304.1

Low Fuel Level Spare =PWRP+ECP3-X300F2 17 03 =PWRP+ECP3-SKTC1 03 =PWRP+ECP3/304.2

Throttle Up =PWRP+ECP3-304S3 40 =PWRP+ECP3-SKTC1 40 =PWRP+ECP3/304.3

Throttle Down =PWRP+ECP3-304S3 22 =PWRP+ECP3-SKTC1 22 =PWRP+ECP3/304.4

Cabin Connected =PWRP+ECP3-X32 50 41 =PWRP+ECP3-SKTC1 41 =PWRP+ECP3/304.5

=PWRP+ECP3-304K6

Low Coolant Level 2 =PWRP+-304S6 12 42 =PWRP+ECP3-SKTC1 42 =PWRP+ECP3/304.6

= SH =PWRP-W32 SH PE =PWRP+ECP3/304.6

Spare 43 =PWRP+ECP3-SKTC1 43 =PWRP+ECP3/304.7

= 04 =PWRP+ECP3-SKTC1 04 =PWRP+ECP3/304.8

Start Engine BN =PWRP+-305Y1 + 48 =PWRP+ECP3-SKTC1 48 =PWRP+ECP3/305.1

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1105 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1107

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X34 TERMINAL STRIP X34 CONTROL PANEL = PWRP + ECP3 - 1106
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W33

CABLE NAME

CABLE NAME
=PWRP+ECP3-X34
TERMINAL STRIP X34 CONTROL PANEL ECP3

Molded-a3 3x1,5 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Start Engine GN/YE =PWRP+-305Y1 PE PE =PWRP+ECP3/305.1

SH =PWRP-W33

Enable Engine =PWRP+ECP3-X32 31 49 =PWRP+ECP3-SKTC1 49 =PWRP+ECP3/305.2

Undervoltage Shutoff =PWRP+ECP3-305K3 A1 31 =PWRP+ECP3-SKTC1 31 =PWRP+ECP3/305.3

Hydraulic Fan Off/On Spare 50 =PWRP+ECP3-SKTC1 50 =PWRP+ECP3/305.4

Spare 51 =PWRP+ECP3-SKTC1 51 =PWRP+ECP3/305.5

= 52 =PWRP+ECP3-SKTC1 52 =PWRP+ECP3/305.6

Enable Manifold =PWRP+ECP3-201K7 12 16 =PWRP+ECP3-SKTC1 16 =PWRP+ECP3/305.7

Spare 35 =PWRP+ECP3-SKTC1 35 =PWRP+ECP3/305.8

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1106 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1108

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X34 TERMINAL STRIP X34 CONTROL PANEL = PWRP + ECP3 - 1107
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W30

=PWRP-W29a

=PWRP-W28

=PWRP-W18

=PWRP-W17

=PWRP-IS-ECP3

CABLE NAME

CABLE NAME
=PWRP+ECP3-X38
TERMINAL STRIP X38 CONTROL PANEL ECP3 (IS)

IS CON. 2x0,75 mm²

IS CON. 2x0,75 mm²

IS CON. 2x0,75 mm²

IS CON. 2x0,75 mm²

IS CON. 2x0,75 mm²

SABIX 1x6 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Dynamo Light bk/ye =PWRP+-IS earth IS-Earth =PWRP+ECP3/200.2

Exhaust Temperature 4-20mA SH =PWRP-W17 SH IS-Earth =PWRP+ECP3/301.4

= SH =PWRP-W18 SH IS-Earth =PWRP+ECP3/301.4

Alternator Signal SH =PWRP-W28 SH IS-Earth =PWRP+ECP3/303.7

Shutdown 2 =PWRP+-303B8 3 1 =PWRP+ECP3/303.8

1 =PWRP+-SKT11

Shutdown IS-Earth =PWRP+ECP3/303.8

= 2 =PWRP+-SKT11 2 2 =PWRP+ECP3/303.9

1 =PWRP+-303S9

Shutdown SH =PWRP-W30 SH IS-Earth =PWRP+ECP3/303.9

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1107 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1109

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X38 TERMINAL STRIP X38 CONTROL PANEL = PWRP + ECP3 - 1108
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

CABLE NAME

CABLE NAME
=PWRP+ECP3-X200F0
TERMINAL STRIP X200F0 CONTROL PANEL ECP3 (24VDC)

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Auxileary Cabin 24VDC Supply 1 =PWRP+ECP3-200D3 3 =PWRP+ECP3/200.4

= 2 =PWRP+ECP3-302S5 13 =PWRP+ECP3/200.4

Enable 24VDC / Start Engine 3 =PWRP+ECP3-200K5 1+ =PWRP+ECP3/200.5

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1108 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1110

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X200F0 TERMINAL STRIP X200F0 CONTROL = PWRP + ECP3 - 1109
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W32

=PWRP-W31

=PWRP-W22

=PWRP-W19

=PWRP-W16

=PWRP-W15

=PWRP-W14

CABLE NAME

CABLE NAME
=PWRP+ECP3-X300F2
TERMINAL STRIP X300F2 CONTROL PANEL ECP3 (24VDC IFM)

RADOX 2x1,5 mm²

RADOX 2x1,5 mm²

RADOX 6x0,5 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

RADOX 3x1 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

VBB r 1 =PWRP+ECP3-300F2 2 =PWRP+ECP3/300.1

= 2 =PWRP+ECP3-300K4 14 =PWRP+ECP3/300.2

Main Pressure 4-20mA 1 =PWRP+-301B1 2 3 =PWRP+ECP3/301.1

Control Pressure 4-20mA 1 =PWRP+-301B2 2 4 =PWRP+ECP3/301.2

Main Generator Pressure 4-20mA 1 =PWRP+-301B3 2 5 =PWRP+ECP3/301.3

= 6 =PWRP+ECP3-301U3 7+ =PWRP+ECP3/301.3

Air Pressure 4-20mA 1 =PWRP+-301B6 2 7 =PWRP+ECP3/301.6

Hold Safety Valve 8 =PWRP+ECP3-302S5 13 =PWRP+ECP3/302.5

Start Engine 9 =PWRP+ECP3-302S6 21 =PWRP+ECP3/302.6

Stop Engine 10 =PWRP+ECP3-302S7 21 =PWRP+ECP3/302.7

Emergency Stop 1 =PWRP+EJB17-X172 1 11 =PWRP+ECP3/302.7

= 12 =PWRP+ECP3-302U8 +A1 =PWRP+ECP3/302.8

Winchpump In Hole 13 =PWRP+ECP3-303S5 13 =PWRP+ECP3/303.5

Start Generator 14 =PWRP+ECP3-303S6 21 =PWRP+ECP3/303.6

Alternator Signal 15 =PWRP+ECP3-303U8 2 =PWRP+ECP3/303.8

Low Hydraulic Oil Level Too Low 1 =PWRP+-304S1 11 16 =PWRP+ECP3/304.1

Low Fuel Level Spare 17 =PWRP+ECP3-X34 03 =PWRP+ECP3/304.2

Throttle Up 18 =PWRP+ECP3-304S3 =PWRP+ECP3/304.3

Throttle Down 19 =PWRP+ECP3-304S3 =PWRP+ECP3/304.4

Low Coolant Level 1 =PWRP+-304S6 11 20 =PWRP+ECP3/304.6

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1109 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB8/1

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+ECP3#-X300F2 TERMINAL STRIP X300F2 CONTROL = PWRP + ECP3 - 1110
0 1 2 3 4 5 6 7 8 9

Powerpack

EJB 160X160X90 POLY ATX ASSY BATTERY


- A1054425
EJB8 PWRP Battery connection box

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+ECP3/1110 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Aug.2011 PAGE DESCRIPTION : Frontpage = PWRP + EJB8 - 1
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-WB2

=PWRP-WB1

CABLE NAME

CABLE NAME

=PWRP-W8

=PWRP-W9

=PWRP-WB3
=PWRP+EJB8-X82
TERMINAL STRIP X82 JUNCTION BOX EJB8

Molded-BK 1x35 mm²

Molded-BK 1x35 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE

GEXOL 1x8 AWG

GEXOL 1x8 AWG

RADOX 1x35 mm²


FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Battery BK =PWRP+-200B1 + 1+ =PWRP+-200S1 4 BK =PWRP+ECP3/200.1

= BK =PWRP+-200B1 - 2- =PWRP+ECP3-X32 6 BK gn/ye =PWRP+ECP3/200.2

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB9/1

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+EJB8#-X82 TERMINAL STRIP X82 JUNCTION BOX = PWRP + EJB8 - 1100
0 1 2 3 4 5 6 7 8 9

Powerpack

EJB 220x220x120 SS ATX ASSY PWRP SUP.


- 8501036543
EJB9 PWRP shore connection

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+EJB8/1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Aug.2011 PAGE DESCRIPTION : Frontpage = PWRP + EJB9 - 1
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W10

CABLE NAME

CABLE NAME
=PWRP+EJB9-XB
TERMINAL STRIP XB JUNCTION BOX EJB9

RADOX 4x6 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Auxileary Cabin 24VDC Supply 1 =PWRP+ECP3-X32 9 + =PWRP+ECP3/200.3

2 =PWRP+ECP3-X32

Auxileary Cabin 24VDC Supply =PWRP+EJB9-PLG6 1 + =PWRP+ECP3/200.4

= =PWRP+EJB9-PLG6 2 + =PWRP+ECP3/200.4

= 3 =PWRP+ECP3-X32 10 - =PWRP+ECP3/200.3

4 =PWRP+ECP3-X32

Auxileary Cabin 24VDC Supply =PWRP+EJB9-PLG6 3 - =PWRP+ECP3/200.4

= =PWRP+EJB9-PLG6 4 - =PWRP+ECP3/200.4

Enable 24VDC / Start Engine SH =PWRP+ECP3-X32 PE PE =PWRP+ECP3/200.5

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE +EJB17/1

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+EJB9#-XB TERMINAL STRIP XB JUNCTION BOX EJB9 = PWRP + EJB9 - 1100
0 1 2 3 4 5 6 7 8 9

Powerpack

EJB 110x75x55 POLY ATX ASSY


- A1070273
EJB17 PWRP Speed sensor box

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
+EJB9/1100 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1100

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Aug.2011 PAGE DESCRIPTION : Frontpage = PWRP + EJB17 - 1
0 1 2 3 4 5 6 7 8 9

Terminal connectionlist

=PWRP-W22

=PWRP-W23

CABLE NAME

CABLE NAME
=PWRP+EJB17-X172
TERMINAL STRIP X172 EJB17

RADOX 6x0,5 mm²

Molded-SP5 5x0.35 mm²

CABLETYPE

CONNECTION

TERMINAL

CONNECTION

CABLETYPE
FUNCTION CODE EXTERN CODE INTERN PAGE / COLOMN

Emergency Stop RD =PWRP+-302S8 +V 1 =PWRP+ECP3/302.7

1 =PWRP+ECP3-X300F2

Emergency Stop BK =PWRP+-302S8 GND 2 =PWRP+ECP3/302.8

2 =PWRP+ECP3-0VDC-E

Generator Frequency BN =PWRP+-302S8 D 3 =PWRP+ECP3/302.8

3 =PWRP+ECP3-X32

Generator Frequency BU =PWRP+-302S8 SIGN 4 =PWRP+ECP3/302.8

4 =PWRP+ECP3-X32

Generator Frequency GN =PWRP+-302S8 sp 5 =PWRP+ECP3/302.8

5 =PWRP+ECP3-X32

Generator Frequency 6 =PWRP+ECP3-X34 PE PE =PWRP+ECP3/302.8

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE =INF+/1400

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Terminalconnectionlist : =PWRP+EJB17#-X172 TERMINAL STRIP X172 EJB17 = PWRP + EJB17 - 1100
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=PWRP+ECP3-X38 =PWRP+-IS
=PWRP-IS-ECP3 SABIX 1x6 mm² 3.5 meter 8501056836
TERMINAL STRIP X38 CONTROL PANEL ECP3 (IS)

=PWRP+ECP1-X11 =PWRP+-SKT1A
=PWRP-W1 RADOX 4x25 mm² 5.5 meter A1055972
TERMINAL STRIP X11 CONTROL PANEL ECP1 Main Power Supply To Cabin

=PWRP+ECP1-X11 =PWRP+-100G0
=PWRP-W2 RADOX 4x25 mm² 3 meter A1055972
= Generator 2x115V 60Hz 30Kw

=PWRP+ECP1-X11 =PWRP+-100G0
=PWRP-W3 RADOX 3x2,5 mm² 3 meter A1049117
Voltage regulation =

=PWRP+ECP1-X14

TERMINAL STRIP X14 CONTROL PANEL ECP1

=PWRP+ECP1-X11 =PWRP+-100X7
=PWRP-W4 RADOX 3x4 mm² 5.5 meter A1055968
TERMINAL STRIP X11 CONTROL PANEL ECP1 Auxiliary Power Socket

=PWRP+ECP1-X11 =PWRP+ECP3-X32
=PWRP-W5 RADOX 7x1 mm² 3 meter A1049155
Voltage / Current signals Enable 24VDC / Start Engine

=PWRP+ECP1-X12 =PWRP+ECP3-X34

TERMINAL STRIP X12 CONTROL PANEL ECP1 TERMINAL STRIP X34 CONTROL PANEL ECP3

=PWRP+ECP3-0VDC-E

Generator Voltage

=PWRP+ECP3-X32 =PWRP+-200G0
=PWRP-W6 RADOX 5x2,5 mm² 4 meter A1055970
TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC) Alternator

=PWRP+ECP3-X32 =PWRP+-200S1
=PWRP-W7 GEXOL 1x8 AWG 3.5 meter A1024932
=

=PWRP+EJB8-X82 =PWRP+-200S1
=PWRP-W8 GEXOL 1x8 AWG 2.5 meter A1024932
TERMINAL STRIP X82 JUNCTION BOX EJB8

=PWRP+ECP3-X32 =PWRP+EJB8-X82
=PWRP-W9 GEXOL 1x8 AWG 2 meter A1024932
TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC) TERMINAL STRIP X82 JUNCTION BOX EJB8

=PWRP+ECP3-X32 =PWRP+EJB9-XB
=PWRP-W10 RADOX 4x6 mm² 3 meter A1055967
= TERMINAL STRIP XB JUNCTION BOX EJB9

=PWRP+ECP3-X32 =PWRP+EJB9-SKT2
=PWRP-W11 SABIX-Multi 25xSpcl mm² 3 meter A1109601
CAN 2 L CAN 2 L

=PWRP+-P1 =PWRP+ECP3-X32
=PWRP-W12 RADOX 18x1 mm² 2.5 meter 8501040372
Engine ECU TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

Unit serial no.


THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
=PWRP+EJB17/1100 PREVIOUS PAGE AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1401

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Cable overview : =PWRP#-IS-ECP3 < = > =PWRP#-W12 = INF + - 1400
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=PWRP+-SKT9 =PWRP+ECP3-X32
=PWRP-W13 RADOX 2x1,5 mm² 2 meter A1064704
TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

=PWRP+ECP3-X34 =PWRP+-301B1
=PWRP-W14 RADOX 3x1 mm² 3 meter A1049118
TERMINAL STRIP X34 CONTROL PANEL ECP3 Main Pressure 4-20mA

=PWRP+ECP3-X300F2

Main Pressure 4-20mA

=PWRP+ECP3-X34 =PWRP+-301B2
=PWRP-W15 RADOX 3x1 mm² 3 meter A1049118
TERMINAL STRIP X34 CONTROL PANEL ECP3 Control Pressure 4-20mA

=PWRP+ECP3-X300F2

Control Pressure 4-20mA

=PWRP+ECP3-X34 =PWRP+-301B3
=PWRP-W16 RADOX 3x1 mm² 3 meter A1049118
TERMINAL STRIP X34 CONTROL PANEL ECP3 Main Generator Pressure 4-20mA

=PWRP+ECP3-X300F2

Main Generator Pressure 4-20mA

=PWRP+ECP3-X38 =PWRP+ECP3-301U3
=PWRP-W17 IS CON. 2x0,75 mm² 2 meter 8501050927
Exhaust Temperature 4-20mA 9182

=PWRP+-301B4

=PWRP+ECP3-X38 =PWRP+ECP3-301U3
=PWRP-W18 IS CON. 2x0,75 mm² 4 meter 8501050927
= 9182

=PWRP+-301B5

Hydraulic Oil Temperature 4-20mA

=PWRP+ECP3-X34 =PWRP+-301B6
=PWRP-W19 RADOX 3x1 mm² 3 meter A1049118
TERMINAL STRIP X34 CONTROL PANEL ECP3 Air Pressure 4-20mA

=PWRP+ECP3-X300F2

Air Pressure 4-20mA

=PWRP+ECP3-0VDC-E =PWRP+-302Y2
=PWRP-W20 RADOX 2x1,5 mm² 6 meter A1064704
Fan Speed

=PWRP+ECP3-X34

TERMINAL STRIP X34 CONTROL PANEL ECP3

=PWRP+ECP3-0VDC-E =PWRP+-302Y3
=PWRP-W21 Molded-a3 3x1,5 mm² A1040277
Pull Safety Valve Air-inlet Valve

Unit serial no.


THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1400 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1402

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Cable overview : =PWRP#-W13 < = > =PWRP#-W21 = INF + - 1401
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=PWRP+ECP3-X32

Pull Safety Valve

=PWRP+ECP3-X34

TERMINAL STRIP X34 CONTROL PANEL ECP3

=PWRP+ECP3-0VDC-E =PWRP+EJB17-X172
=PWRP-W22 RADOX 6x0,5 mm² 3 meter A1064046
Emergency Stop Emergency Stop

=PWRP+ECP3-X32

TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

=PWRP+ECP3-X34

Generator Frequency

=PWRP+ECP3-X300F2

Emergency Stop

=PWRP+EJB17-X172 =PWRP+-302S8
=PWRP-W23 Molded-SP5 5x0.35 mm² 0.5 m A1040277
TERMINAL STRIP X172 EJB17 Speedsensor Generator

=PWRP+ECP3-0VDC-E =PWRP+-303Y1
=PWRP-W24 RADOX 3x1 mm² 3 meter A1049118
Generator pump Generator pump

=PWRP+ECP3-X32

TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

=PWRP+ECP3-X34

Pumpmotor Generator Displacment

=PWRP+ECP3-0VDC-E =PWRP+-303Y2
=PWRP-W25 RADOX 3x1 mm² 3.5 meter A1049118
Relief Valve Drum Relief Valve Drum

=PWRP+ECP3-X32

TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

=PWRP+ECP3-X34

Relief Valve Drum

=PWRP+ECP3-0VDC-E =PWRP+-303Y3
=PWRP-W26 RADOX 3x1 mm² 3 meter A1049118
Winchpump Out Hole Winchpump Out Hole

=PWRP+ECP3-X32

TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

=PWRP+ECP3-0VDC-E =PWRP+-303Y4
=PWRP-W27 RADOX 3x1 mm² 3 meter A1049118
Winchpump In Hole Winchpump In Hole

Unit serial no.


THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1401 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1403

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD 11.Feb.2015 PAGE DESCRIPTION : Cable overview : =PWRP#-W21 < = > =PWRP#-W27 = INF + - 1402
0 1 2 3 4 5 6 7 8 9

Cable overview
CORE TO CORE
CABLE CODE FROM TO CABLE TYPE CORES LENGTH A. NUMBER TEST VOLT. VALUE SIGN.
REEL #
=PWRP+ECP3-X32

TERMINAL STRIP X22 CONTROL PANEL ECP3 (24VDC)

=PWRP+-303B8 =PWRP+ECP3-X38
=PWRP-W28 IS CON. 2x0,75 mm² 3 meter 8501050927
Oil Pressure TERMINAL STRIP X38 CONTROL PANEL ECP3 (IS)

=PWRP+ECP3-303U8

Shutdown

=PWRP+-PLG11 =PWRP+-303S8
=PWRP-W29 IS CON. 2x0,75 mm² 0.5 meter 8501050927
Exhaust Temp.

=PWRP+-SKT11 =PWRP+ECP3-X38
=PWRP-W29a IS CON. 2x0,75 mm² 2 meter 8501050927
TERMINAL STRIP X38 CONTROL PANEL ECP3 (IS)

=PWRP+-303S9 =PWRP+ECP3-X38
=PWRP-W30 IS CON. 2x0,75 mm² 3 meter 8501050927
Coolant Temp. =

=PWRP+ECP3-303U8

9170/20-10-11K

=PWRP+ECP3-X34 =PWRP+-304S1
=PWRP-W31 RADOX 2x1,5 mm² 3.5 meter A1064704
TERMINAL STRIP X34 CONTROL PANEL ECP3 Low Hydr. Oil Level

=PWRP+ECP3-X300F2

Low Hydraulic Oil Level Too Low

=PWRP+ECP3-X34 =PWRP+-304S6
=PWRP-W32 RADOX 2x1,5 mm² 4 meter A1064704
TERMINAL STRIP X34 CONTROL PANEL ECP3 Low Coolant Level

=PWRP+ECP3-X300F2

Low Coolant Level

=PWRP+ECP3-0VDC-E =PWRP+-305Y1
=PWRP-W33 Molded-a3 3x1,5 mm² 3 meter A1040277
Start Engine Start Engine

=PWRP+ECP3-X34

TERMINAL STRIP X34 CONTROL PANEL ECP3

=PWRP+EJB8-X82 =PWRP+-200B1
=PWRP-WB1 Molded-BK 1x35 mm² A1040277
TERMINAL STRIP X82 JUNCTION BOX EJB8

=PWRP+EJB8-X82 =PWRP+-200B1
=PWRP-WB2 Molded-BK 1x35 mm² A1040277
=

=PWRP+EJB8-X82 =PWRP+-PE
=PWRP-WB3 RADOX 1x35 mm² 3.5 meter A1061778
=

Unit serial no.


THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1402 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1500

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Cable overview : =PWRP#-W27 < = > =PWRP#-WB3 = INF + - 1403
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS IP Rating Temperature ranges PART NUMBER PAGE COLUMN

=PWRP+-200B1 1 BATTERY 24V IP 21 -20°C to +40°C A1044994 =PWRP+ECP3/200 1

=PWRP+-301B1 1 PRESSURE TRANSMITTER IP 65 -40°C to +125°C A1067640 =PWRP+ECP3/301 1

=PWRP+-301B1 1 PLUG IP 65 -20°C to +40°C A1099135 =PWRP+ECP3/301 1

=PWRP+-301B2 1 PRESSURE TRANSMITTER IP 65 -40°C to +125°C A1066387 =PWRP+ECP3/301 2

=PWRP+-301B2 1 PLUG IP 65 -20°C to +40°C A1099135 =PWRP+ECP3/301 2

=PWRP+-301B3 1 PRESSURE TRANSMITTER IP 65 -40°C to +125°C A1067640 =PWRP+ECP3/301 3

=PWRP+-301B3 1 PLUG IP 65 -20°C to +40°C A1099135 =PWRP+ECP3/301 3

=PWRP+-301B4 1 TEMPERATURE SENSOR IP 67 -50°C to +200°C A1059899 =PWRP+ECP3/301 4

=PWRP+-301B4 1 PROTECTION TUBE -- -- A1060300 =PWRP+ECP3/301 4

=PWRP+-301B5 1 TEMPERATURE SENSOR IP 67 -50°C to +200°C A1059899 =PWRP+ECP3/301 5

=PWRP+-301B5 1 PROTECTION TUBE -- -- A1060300 =PWRP+ECP3/301 5

=PWRP+-301B6 1 PRESSURE TRANSMITTER IP 65 -40°C to +125°C A1066387 =PWRP+ECP3/301 6

=PWRP+-301B6 1 PLUG IP 65 -20°C to +40°C A1099135 =PWRP+ECP3/301 6

=PWRP+-303B8 1 PRESSURE SWITCH IP 65 -40°C to +80°C A1109848 =PWRP+ECP3/303 7

=PWRP+-ECP1 1 ECP1 IP 66 -20°C to +50°C 8501036539 =PWRP+ECP1/100 0

=PWRP+-ECP3 1 ECP3 IP .. -20°C to +40°C 8501035867 =PWRP+ECP3/200 0

=PWRP+-EJB8 1 BOX 160x160x90 IP 54 -20°C to +55°C A1054425 =PWRP+ECP3/200 1

=PWRP+-EJB9 1 EJB 220x220x100 IP 65 -20°C to +50°C 8501036543 =PWRP+ECP3/200 3

=PWRP+-EJB17 1 EJB 110x75x55 IP 65 -20°C to +55°C A1070273 =PWRP+ECP3/302 7

=PWRP+-100G0 1 GENERATOR IP 20 -20°C to +50°C A1059353 =PWRP+ECP1/100 0

=PWRP+-200G0 1 ALTERNATOR 24V 25A IP 66 -30°C to +50°C A1033192 =PWRP+ECP3/200 0

=PWRP+-201H4 1 HANDHELD LIGHT IP 68 -20°C to +50°C A1014454 =PWRP+ECP3/201 4

=PWRP+-P1 1 ENGINE ECU CONN C6.6 -- -- A1084107 =PWRP+ECP3/201 0

=PWRP+-PLG9 1 CAP INLET IP 66 -40°C to +60°C A0019513 =PWRP+ECP3/201 4

=PWRP+-PLG9 1 PLUG HOUSING IP 66 -40°C to +60°C A0019134 =PWRP+ECP3/201 4

=PWRP+-PLG9 1 PLUG IP 66 -40°C to +60°C A1026145 =PWRP+ECP3/201 4

=PWRP+-PLG11 1 RECEPTACLE IP 40 -55°C to +125°C A1056235 =PWRP+ECP3/303 8

=PWRP+-PLG11 1 WEDGE IP 40 -55°C to +125°C A1058936 =PWRP+ECP3/303 8

=PWRP+-PLG11 1 CONNECTORS 14AWG IP 56 -55°C to +125°C A1055544 =PWRP+ECP3/303 8

=PWRP+-200S1 1 SWITCH 32A IP 65 -50°C to +80°C A1061325 =PWRP+ECP3/200 1

=PWRP+-302S8 1 SPEED SENSOR IP 69K -40°C to +50°C 6501048420 =PWRP+ECP3/302 7

=PWRP+-303S8 1 TEMPERATURE SWITCH IP 65 -30°C to +70°C 6501065098 =PWRP+ECP3/303 8

=PWRP+-303S9 1 TEMPERATURE SWITCH IP 65 -30°C to +70°C 6501063072 =PWRP+ECP3/303 9

=PWRP+-304S1 1 SENSOR IP 54 -40°C to +120°C A1066393 =PWRP+ECP3/304 1

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1403 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1501

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Bill of materials electric = INF + - 1500
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS IP Rating Temperature ranges PART NUMBER PAGE COLUMN

=PWRP+-304S6 1 SENSOR IP 54 -40°C to +120°C A1066393 =PWRP+ECP3/304 6

=PWRP+-SKT1A 1 SOCKET 3P+N+E IP 65 -40°C to +60°C A1059801 =PWRP+ECP1/100 9

=PWRP+-SKT1A 1 WALLBOX IP 65 -40°C to +60°C A1059800 =PWRP+ECP1/100 9

=PWRP+-SKT9 1 WALL BOX IP 66 -40°C to +60°C A0020281 =PWRP+ECP3/201 4

=PWRP+-SKT9 1 SOCKET IP 66 -40°C to +60°C A1026144 =PWRP+ECP3/201 4

=PWRP+-SKT11 1 WEDGE IP 40 -55°C to +125°C A1056238 =PWRP+ECP3/303 8

=PWRP+-SKT11 1 RECEPTACLE IP 40 -55°C to +125°C A1056235 =PWRP+ECP3/303 8

=PWRP+-SKT11 1 CONNECTORS 14AWG IP 56 -55°C to +125°C A1055546 =PWRP+ECP3/303 8

=PWRP+-201U3 1 ENGINE PRO C6.6 -- -- 8501034376 =PWRP+ECP3/201 3

=PWRP+-100X7 1 SOCKET 1P+N IP 66 -40°C to +60°C A0019870 =PWRP+ECP1/100 7

=PWRP+-100X7 1 WALLBOX IP 66 -40°C to +60°C A0019869 =PWRP+ECP1/100 7

=PWRP+-100X7 1 PLUG HOUSING IP 66 -40°C to +60°C A0019871 =PWRP+ECP1/100 7

=PWRP+-100X7 1 PLUG 1P+N IP 66 -40°C to +60°C A0019872 =PWRP+ECP1/100 7

=PWRP+-100X7 1 PLUG COVER IP 66 -40°C to +60°C A0019873 =PWRP+ECP1/100 7

=PWRP+-302Y2 1 PLUG 2P+PE IP 65 -20°C to +40°C A1099133 =PWRP+ECP3/302 2

=PWRP+-302Y3 1 VALVE IP 66 -30°C to +50°C A1033195 =PWRP+ECP3/302 3

=PWRP+-303Y1 1 PUMP IP65 -25°C to +115°C A1072900 =PWRP+ECP3/303 1

=PWRP+-303Y1 1 PLUG 2P+PE IP 65 -20°C to +40°C A1099133 =PWRP+ECP3/303 1

=PWRP+-303Y2 1 PLUG 2P+PE IP 65 -20°C to +40°C A1099133 =PWRP+ECP3/303 2

=PWRP+-303Y3 1 SOLENOID IP 65 +50°C A0020417 =PWRP+ECP3/303 3

=PWRP+-303Y3 1 PLUG 2P+PE IP 65 -20°C to +40°C A1099133 =PWRP+ECP3/303 3

=PWRP+-303Y4 1 SOLENOID IP 65 +50°C A0020417 =PWRP+ECP3/303 4

=PWRP+-303Y4 1 PLUG 2P+PE IP 65 -20°C to +40°C A1099133 =PWRP+ECP3/303 4

=PWRP+-305Y1 1 3/2 VALVE -10...60 A0001942 =PWRP+ECP3/305 1

=PWRP+-305Y1 1 SOLENOID IP 65 -20°C to +50°C A0011352 =PWRP+ECP3/305 1

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1502

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Bill of materials electric = INF + - 1501
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS IP Rating Temperature ranges PART NUMBER PAGE COLUMN

=PWRP+ECP1-100B0 1 GENERATOR REGULATOR IP 20 -40°C to +60°C 8501056374 =PWRP+ECP1/100 1

=PWRP+ECP1-100B5 1 AC/DC TRANSMITTER IP 50 -20° to +60°C A1059744 =PWRP+ECP1/100 5

=PWRP+ECP1-100B5 1 RELAY SOCKET 11P -- -40°C to +60°C 8501040842 =PWRP+ECP1/100 5

=PWRP+ECP1-100B5 1 RETENTION CLIP -- -- 8501040843 =PWRP+ECP1/100 5

=PWRP+ECP1-100F0A 1 FUSE 6.3A 250VAC -- -30°C to +70°C A0010259 =PWRP+ECP1/100 1

=PWRP+ECP1-100F0B 1 FUSE 6.3A 250VAC -- -30°C to +70°C A0010259 =PWRP+ECP1/100 1

=PWRP+ECP1-100F1 1 FUSE 5A 250VAC -- -30°C to +70°C A0015575 =PWRP+ECP1/100 1

=PWRP+ECP1-100F2 1 FUSE 5A 250VAC -- -30°C to +70°C A0015575 =PWRP+ECP1/100 2

=PWRP+ECP1-100F3 1 FUSE 5A 250VAC -- -30°C to +70°C A0015575 =PWRP+ECP1/100 2

=PWRP+ECP1-100F5 1 FUSE 1A 250VAC -- -30°C to +70°C A0000934 =PWRP+ECP1/100 5

=PWRP+ECP1-100F7 1 MCB 2P D32A 20kA IP 20 -25°C to +55°C 8501040832 =PWRP+ECP1/100 7

=PWRP+ECP1-100H2 1 LIGHT SIGNAL IP 65 -20°C to +40°C A1035286 =PWRP+ECP1/100 2

=PWRP+ECP1-100H2 1 LIGHT SIGNAL IP 56 -20°C to +60°C A1105420 =PWRP+ECP1/100 2

=PWRP+ECP1-100H3 1 LIGHT SIGNAL IP 56 -20°C to +60°C A1105420 =PWRP+ECP1/100 3

=PWRP+ECP1-100H3 1 LIGHT SIGNAL GREEN IP 66 -20°C to +40°C A1035290 =PWRP+ECP1/100 3

=PWRP+ECP1-100K1 1 DIGITAL MONITORING IP 20 -25°C to +60°C A1112821 =PWRP+ECP1/100 1

=PWRP+ECP1-100K2 1 RELAIS IP2x -40°C to +70°C A1086670 =PWRP+ECP1/100 2

=PWRP+ECP1-100Q0 1 MCB 3P 125A VL160X N IP 20 -25°C to +70°C 8501040837 =PWRP+ECP1/100 0

=PWRP+ECP1-100Q0 1 DOOR COUPL IP 65 -25°C to +70°C 8501040839 =PWRP+ECP1/100 0

=PWRP+ECP1-100Q0 1 TERMINAL COVER IP 20 -25°C to +70°C 8501040840 =PWRP+ECP1/100 0

=PWRP+ECP1-100T4 1 TRAFO FOR AMPS IP 20 -10°C to +55°C 8501058572 =PWRP+ECP1/100 4

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1503

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Bill of materials electric = INF + - 1502
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS IP Rating Temperature ranges PART NUMBER PAGE COLUMN

=PWRP+ECP3-200D0 1 DIODE -- +150°C A1066383 =PWRP+ECP3/200 0

=PWRP+ECP3-200D1 1 DIODE -- +150°C A1066383 =PWRP+ECP3/200 0

=PWRP+ECP3-200D2 1 SINGLE DIODE -- +150C° A1080309 =PWRP+ECP3/200 1

=PWRP+ECP3-200D3 1 DIODE -- +150°C A1066383 =PWRP+ECP3/200 3

=PWRP+ECP3-200D3.1 1 DIODE -- +150°C A1066383 =PWRP+ECP3/200 3

=PWRP+ECP3-200F0 1 FUSE -- -20°C to +60°C A1085720 =PWRP+ECP3/200 0

=PWRP+ECP3-200F0 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/200 0

=PWRP+ECP3-200F6 1 FUSE -- -20°C to +60°C A1085719 =PWRP+ECP3/200 6

=PWRP+ECP3-200F6 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/200 6

=PWRP+ECP3-200F8 1 FUSE -- -20°C to +60°C A1085716 =PWRP+ECP3/200 8

=PWRP+ECP3-200F8 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/200 8

=PWRP+ECP3-200F9 1 FUSE -- -20°C to +60°C A1085712 =PWRP+ECP3/200 9

=PWRP+ECP3-200F9 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/200 9

=PWRP+ECP3-201F1 1 FUSE -- -20°C to +60°C A1085720 =PWRP+ECP3/201 1

=PWRP+ECP3-201F1 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/201 1

=PWRP+ECP3-201F4 1 FUSE -- -20°C to +60°C A1085707 =PWRP+ECP3/201 4

=PWRP+ECP3-201F4 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/201 4

=PWRP+ECP3-201F5 1 FUSE -- -20°C to +60°C A1085707 =PWRP+ECP3/201 5

=PWRP+ECP3-201F5 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/201 5

=PWRP+ECP3-300F0 1 FUSE -- -20°C to +60°C A1085712 =PWRP+ECP3/300 0

=PWRP+ECP3-300F0 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/300 0

=PWRP+ECP3-300F1 1 FUSE -- -20°C to +60°C A1085715 =PWRP+ECP3/300 1

=PWRP+ECP3-300F1 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/300 1

=PWRP+ECP3-300F2 1 FUSE -- -20°C to +60°C A1085714 =PWRP+ECP3/300 1

=PWRP+ECP3-300F2 1 FUSE HOLDER -- -20°C to +40°C A1079006 =PWRP+ECP3/300 1

=PWRP+ECP3-200H2 1 LED MODULE RED IP 20 -55°C to + 50°C A1048931 =PWRP+ECP3/200 2

=PWRP+ECP3-200H2 1 COVER LEDMODULE IP 54 -55°C to +70°C A0011041 =PWRP+ECP3/200 2

=PWRP+ECP3-200K5 1 SOLID STATE RELAY IP 20 -25°C to +90°C A1080373 =PWRP+ECP3/200 4

=PWRP+ECP3-200K6 1 RELAY IP 20 -20°C to +60°C A1060263 =PWRP+ECP3/200 5

=PWRP+ECP3-201K5 1 RELAY 24Vdc IP 20 -25°C to +40°C A1029768 =PWRP+ECP3/201 5

=PWRP+ECP3-201K6 1 RELAY IP 20 -20°C to +60°C A1060263 =PWRP+ECP3/201 6

=PWRP+ECP3-201K7 1 RELAY 24Vdc IP 20 -25°C to +40°C A1029768 =PWRP+ECP3/201 7

=PWRP+ECP3-300K4 1 RELAY 24Vdc IP 20 -25°C to +40°C A1029768 =PWRP+ECP3/300 3

=PWRP+ECP3-302K3 1 SOLID STATE RELAY IP 20 -25°C to +90°C A1080373 =PWRP+ECP3/302 3

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1502 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1504

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Bill of materials electric = INF + - 1503
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS IP Rating Temperature ranges PART NUMBER PAGE COLUMN

=PWRP+ECP3-304K6 1 RELAY IP 20 -20°C to +60°C A1060263 =PWRP+ECP3/304 5

=PWRP+ECP3-305K3 1 RELAY IP 20 -20°C to +60°C A1060263 =PWRP+ECP3/305 3

=PWRP+ECP3-300P4 1 KANTRAK DISPLAY IP67 -40°C to +40°C 6501052598 =PWRP+ECP3/300 4

=PWRP+ECP3-300P4 1 PLUG IP 40 -55°C to +125°C A1061630 =PWRP+ECP3/300 4

=PWRP+ECP3-300P4 1 WEDGE IP 40 -55°C to +125°C A1061631 =PWRP+ECP3/300 4

=PWRP+ECP3-200R1 1 RESISTOR 200 Ohm -- -40°C to +50°C A1065792 =PWRP+ECP3/200 1

=PWRP+ECP3-201S5 1 POSITION SELECTOR IP 54 -55°C to +70°C A0021204 =PWRP+ECP3/201 5

=PWRP+ECP3-201S5 1 SWITCH MODULE IP 20 -55°C to +60°C A1059770 =PWRP+ECP3/201 5

=PWRP+ECP3-302S5 1 SWITCH MODULE IP 20 -55°C to +60°C A1026946 =PWRP+ECP3/302 5

=PWRP+ECP3-302S5 1 PUSH BUTTON IP 54 -55°C to +70°C A0021202 =PWRP+ECP3/302 5

=PWRP+ECP3-302S6 1 SWITCH MODULE IP 20 -55°C to +60°C A1059770 =PWRP+ECP3/302 6

=PWRP+ECP3-302S6 1 PUSH BUTTON IP 54 -55°C to +70°C A0021202 =PWRP+ECP3/302 6

=PWRP+ECP3-302S7 1 SWITCH MODULE IP 20 -55°C to +60°C A1059770 =PWRP+ECP3/302 7

=PWRP+ECP3-302S7 1 EMERGENCY STOP IP 66 -20°C / +70°C A0021203 =PWRP+ECP3/302 7

=PWRP+ECP3-303S5 1 SWITCH MODULE IP 20 -55°C to +60°C A1059770 =PWRP+ECP3/303 5

=PWRP+ECP3-303S5 1 PUSH BUTTON IP 54 -55°C to +70°C A0021202 =PWRP+ECP3/303 5

=PWRP+ECP3-303S6 1 SWITCH MODULE IP 20 -55°C to +60°C A1059770 =PWRP+ECP3/303 6

=PWRP+ECP3-303S6 1 PUSH BUTTON IP 54 -55°C to +70°C A0021202 =PWRP+ECP3/303 6

=PWRP+ECP3-304S3 1 SWITCH MODULE IP 20 -55°C to +60°C A1026946 =PWRP+ECP3/304 3

=PWRP+ECP3-304S3 1 DOUBLE PUSHBUTTON IP 54 -55°C to +70°C A1040349 =PWRP+ECP3/304 3

=PWRP+ECP3-SKTC2 1 RECEPTACLE 10S IP 56 -40°C to +80°C A1083957 =PWRP+ECP3/300 3

=PWRP+ECP3-SKTC2 1 DUST CAP+CHAIN (PS) IP 68 -65°C to +200°C A1082717 =PWRP+ECP3/300 3

=PWRP+ECP3-201U3 1 EMC FILTER -- -20°C to +50°C 6501062625 =PWRP+ECP3/201 3

=PWRP+ECP3-300U0 1 SAFETY CONTROLLER IP 67 -40°C to +75°C 6501052994 =PWRP+ECP3/300 0

=PWRP+ECP3-300U0 1 CONNECTOR FOR IFM IP 54 -40°C to +80°C A1056781 =PWRP+ECP3/300 0

=PWRP+ECP3-300U8 1 EMC FILTER -- -20°C to +50°C 6501062625 =PWRP+ECP3/300 8

=PWRP+ECP3-301U3 1 ISOLATOR IP 20 -20°C to +60°C A1065727 =PWRP+ECP3/301 3

=PWRP+ECP3-302U1 1 SIGNAL CONVERTER IP 20 -40°C to +80°C A1064771 =PWRP+ECP3/302 1

=PWRP+ECP3-302U8 1 SIGNAL CONVERTER IP 20 -40°C to +80°C A1064771 =PWRP+ECP3/302 8

=PWRP+ECP3-303U8 1 ISOLATOR IP20 -20°C to +60°C A1080113 =PWRP+ECP3/303 8

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1503 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 1505

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Bill of materials electric = INF + - 1504
0 1 2 3 4 5 6 7 8 9

Bill of materials
CODE Σ SPECIFICATIONS IP Rating Temperature ranges PART NUMBER PAGE COLUMN

=PWRP+EJB9-PLG6 1 RECEPTACLE IP68-8 -20ºC to +40°C A1100399 =PWRP+ECP3/200 4

=PWRP+EJB9-SKT2 1 CAP SHELL SIZE 32 IP 68 -55°C to +125°C A1061894 =PWRP+ECP3/300 9

=PWRP+EJB9-SKT2 1 RECEPTACLE 23S IP 56 -40°C to +80°C A1068666 =PWRP+ECP3/300 9

=PWRP+EJB9-SKT2 1 FIXED ADAPTOR IP 67 -65°C to +200°C A1082447 =PWRP+ECP3/300 9

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1504 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2500

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Bill of materials electric = INF + - 1505
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


Prot. Type ATEX Prot. Type IECEx VOLTAGE POWER IP Rating
TYPE NUMBER Part Number
CODE SERIAL SPECIFICATIONS Certificate ATEX Certificate IECEx CURRENT Temp. Ranges

II 3 G Ex nA II T3 IP 20
=PWRP+-100G0 30Kw GENERATOR 115/230V 50/60HZ ATX A1059353 A1059353
Epsilon07ATEX2233X A -20°C to +50°C

Ex II 2 G Ex d e IIC T6 230 VAC IP 66


=PWRP+-100X7 DXN6 insert 1P+N 230V F 2564015 844 A0019870
LCIE05ATEX6150 63 A -40°C to +60°C

Ex II 2 G Ex d e IIC T6 IP 66
=PWRP+-100X7 DXN6 Wall box 30° M25 256AB53 A0019869
LCIE05ATEX6150 A -40°C to +60°C

Ex II 2 G Ex d e IIC T6 IP 66
=PWRP+-100X7 DXN6 plug housing M32 256A 2540P A0019871
LCIE05ATEX6150 A -40°C to +60°C

Ex II 2 G Ex d e IIC T6 230 VAC IP 66


=PWRP+-100X7 DXN6 insert 1P+N 230V M 2568015 A0019872
LCIE05ATEX6150 63 A -40°C to +60°C

Ex II 2 G Ex d e IIC T6 IP 66
=PWRP+-100X7 DXN6 plug cover 256A126 A0019873
LCIE05ATEX6150 A -40°C to +60°C

II 3G EExe -20°C..+40°C IP 21
=PWRP+-200B1 Battery 24V 65Ah ATEX II 3G Zone 2 -20+40°C BATTERY 24V 65AH ATEX -20 A1044994
Serial A -20°C to +40°C

II 2GD Ex IIB T4 Gb Ex d IIB T4 GbEx tb IIIC 24 VDC IP 66


=PWRP+-200G0 ALTERNATOR 24V 25A ATX ASX-300 A1033192
SIRA99ATEX1127X IECExSIR120132X 25 A -30°C to +50°C

II 2G Ex d IIB T6 690 VAC -- IP 65


=PWRP+-200S1 SWITCH 32A 4 POLE ATX > EFS4 32A/C A1061325
BVI07ATEX0028 32 A -50°C to +80°C

Ex II 2 GD Ex mb e II CT5 Gb 24 V IP 68
=PWRP+-201H4 Handheld 24V DC AC 50/60Hz 8W EX TL Light KE EX 4008/24-10 (139003) A1014454
ISSeP08ATEX046 A -20°C to +50°C

Ex II 3 G Ex nA nC II T3 --
=PWRP+-201U3 ENGINE PRO C6.6 CONN COMPLETE WITH CAB 8501034376 ASSY 8501034376
EPSILON07ATEX2229X A --

Ex II 3 G Ex nA II T3 IP 65
=PWRP+-301B1 PRESSURE TRANSMITTER 600 BAR ATX 8298.86.25.17.04.19.43.58 A1067640
EPSILON07ATEX2230X A -40°C to +125°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-301B1 Plug 3p+PE ATEX Ex nA IIB T4 X (connector) C18309W21ATXE A1099135
CE-10003782 - A -20°C to +40°C

Ex II 3 G Ex nA II T3 IP 65
=PWRP+-301B2 PRESSURE TRANSMITTER 60 BAR ATX PTX 1400 60 BAR SEALED GAUGE A1066387
EPSILON07ATEX2230X 50 A -40°C to +125°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-301B2 Plug 3p+PE ATEX Ex nA IIB T4 X (connector) C18309W21ATXE A1099135
CE-10003782 - A -20°C to +40°C

Ex II 3 G Ex nA II T3 IP 65
=PWRP+-301B3 PRESSURE TRANSMITTER 600 BAR ATX 8298.86.25.17.04.19.43.58 A1067640
EPSILON07ATEX2230X A -40°C to +125°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-301B3 Plug 3p+PE ATEX Ex nA IIB T4 X (connector) C18309W21ATXE A1099135
CE-10003782 - A -20°C to +40°C

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
1505 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2501

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Hazardous area schedule = INF + - 2500
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


Prot. Type ATEX Prot. Type IECEx VOLTAGE POWER IP Rating
TYPE NUMBER Part Number
CODE SERIAL SPECIFICATIONS Certificate ATEX Certificate IECEx CURRENT Temp. Ranges

Simple Apparatus IP 67
=PWRP+-301B4 TEMPERATURE SENSOR PT100 WITH DIN CAP, 1/2"BSP, MK.0.1.0.0.2.C.-XXX A1059899
Simple Apparatus A -50°C to +200°C

Simple Apparatus IP 67
=PWRP+-301B5 TEMPERATURE SENSOR PT100 WITH DIN CAP, 1/2"BSP, MK.0.1.0.0.2.C.-XXX A1059899
Simple Apparatus A -50°C to +200°C

Ex II 3 G Ex nA II T3 IP 65
=PWRP+-301B6 PRESSURE TRANSMITTER 60 BAR ATX PTX 1400 60 BAR SEALED GAUGE A1066387
EPSILON07ATEX2230X 50 A -40°C to +125°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-301B6 Plug 3p+PE ATEX Ex nA IIB T4 X (connector) C18309W21ATXE A1099135
CE-10003782 - A -20°C to +40°C

II 3G Ex nA II T5 IP 69K
=PWRP+-302S8 SPEED SENSOR HYDRO LEDUC ATX 6501048420 6501048420
DOC-CE-1048420 A -40°C to +50°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-302Y2 Plug 2p+PE ATEX Ex nA IIB T4 X (connector) [EX] C18209W21A-Pneutec A1099133
CE-10003780 - A -20°C to +40°C

II 2 GD EEx e II T4 IP 66
=PWRP+-302Y3 Diesel engine inlet safety shut down valve 24V NC ATEX EEx e I SVX-330 A1033195
SIRA99ATEX3186X A -30°C to +50°C

Simple Apparatus Simple Apparatus IP 65


=PWRP+-303B8 PRESSURE SWITCH 2 BAR FALLING PS71-10-4MGZ-C-H-FS2BARF A1109848
Simple Apparatus Simple Apparatus A -40°C to +80°C

Simple Apparatus Simple Apparatus IP 65


=PWRP+-303S8 TEMPERATURE SWITCH 200°C TYPE 471 6501065098 6501065098
Simple Apparatus Simple Apparatus A -30°C to +70°C

Simple Apparatus Simple Apparatus IP 65


=PWRP+-303S9 TEMPERATURE SWITCH 100°C TYPE 474 6501063072 6501063072
Simple Apparatus Simple Apparatus A -30°C to +70°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-303Y1 Plug 2p+PE ATEX Ex nA IIB T4 X (connector) [EX] C18209W21A-Pneutec A1099133
CE-10003780 - A -20°C to +40°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-303Y2 Plug 2p+PE ATEX Ex nA IIB T4 X (connector) [EX] C18209W21A-Pneutec A1099133
CE-10003780 - A -20°C to +40°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-303Y3 Plug 2p+PE ATEX Ex nA IIB T4 X (connector) [EX] C18209W21A-Pneutec A1099133
CE-10003780 - A -20°C to +40°C

II 3 G Ex nA IIB T4 X Safe area IP 65


=PWRP+-303Y4 Plug 2p+PE ATEX Ex nA IIB T4 X (connector) [EX] C18209W21A-Pneutec A1099133
CE-10003780 - A -20°C to +40°C

II 3G Ex nA nC II T3 IP 54
[EX] Epsilon Certified Liquid level sensor SSF212XP EX II 3 G n
=PWRP+-304S1 A1066393 A1066393
II T3
Epsilon07ATEX2236X A -40°C to +120°C

II 3G Ex nA nC II T3 IP 54
[EX] Epsilon Certified Liquid level sensor SSF212XP EX II 3 G n
=PWRP+-304S6 A1066393 A1066393
II T3
Epsilon07ATEX2236X A -40°C to +120°C

=PWRP+-305Y1 3/2 valve G1/8 elec. without control A1E130 A0001942


A -10...60

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2500 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2502

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Hazardous area schedule = INF + - 2501
0 1 2 3 4 5 6 7 8 9

Hazardous area schedule


Prot. Type ATEX Prot. Type IECEx VOLTAGE POWER IP Rating
TYPE NUMBER Part Number
CODE SERIAL SPECIFICATIONS Certificate ATEX Certificate IECEx CURRENT Temp. Ranges

Ex II 2 G EEx m II T4 IP 65
Solenoid 24VDC II 2G Ex m II T4 c/w 10mtr cable without ODU
=PWRP+-305Y1 System 8 1213 T4 24VDC 10m A0011352
plug
PTB00ATEX2001X A -20°C to +50°C

Ex II 2G Ex d II B T5 IP 66
=PWRP+-ECP1 ECP1 PWRP 2x115V 125A GEN 30kW ATX> BARTEC-B-COR-45B 8501036539
KEMA08ATEX0123 A -20°C to +50°C

Ex II 3 (1) G Ex de nA nC nL IP ..
=PWRP+-ECP3 ECP3 PWRP 24V CAT6.6 IFM ATX > 8501035867 8501035867
Serial A -20°C to +40°C

Ex II 2G EEx e ia/ib IIA IIB II IP 54


=PWRP+-EJB8 Box 160x160x90 EEx-e polyester black + 4x M25 07-5195-1601/6090 A1054425
PTB01ATEX1104 A -20°C to +55°C

Ex II 3G Ex de nA IIC T3 X IP 65
=PWRP+-EJB9 EJB 220x220x100 PWRP SGNL. CON. AND SUPPLY 24V ATX BARTEC-A-STD-S2210 8501036543
Serial A -20°C to +50°C

Ex II 2G EXe II T5 IP 65
=PWRP+-EJB17 EJB 110x75x55 POLY ATX ATX 07-5103-1100/7555 2xM16-B A1070273
PTB 08 ATEX 1064 A -20°C to +55°C

Ex II 3 G Ex nA nC II T3 --
=PWRP+-P1 ENGINE ECU CONN C6.6 COMPLETE WITH CABL A1084107 ASSY A1084107
EPSILON07ATEX2229X A --

Ex II 2 GD Ex de IIC T* Ex d e IIC T* IP 66
=PWRP+-PLG9 DXN1 inlet cap (plug cover) DXN1 25 1A 126 A0019513
LCIE99ATEX6027X IECEx LCI 09.0005X A -40°C to +60°C

Ex II 2 GD Ex de IIC T* Ex d e IIC T* IP 66
=PWRP+-PLG9 DXN1 plug housing Straight handle for connector PG M25 251A 25325P A0019134
LCIE99ATEX6027X IECEx LCI 09.0005X A -40°C to +60°C

Ex II 2 GD Ex de IIC T* Ex d e IIC T* 24 V IP 66
=PWRP+-PLG9 DXN1 2P+- 24V M 251808A A1026145
LCIE99ATEX6027X IECEx LCI 09.0005X 20 A -40°C to +60°C

Ex II2 G/D - Ex de IIC T* Ex d e IIC T* IP 65


=PWRP+-SKT1A DX9 insert 3P+N+E 380-440V 60Hz Female 2694017 A1059801
LCIE04ATEX6038 IECEx LCI 09.0015X 63 A -40°C to +60°C

Ex II2 G/D - Ex de IIC T* Ex d e IIC T* IP 65


=PWRP+-SKT1A DX9 Wall box 269AB53 A1059800
LCIE04ATEX6038 IECEx LCI 09.0015X 63 A -40°C to +60°C

Ex II 2 GD Ex de IIC T* Ex d e IIC T* IP 66
=PWRP+-SKT9 DXN1 poly wall box 30deg M20 251AB53 A0020281
LCIE99ATEX6027X IECEx LCI 09.0005X A -40°C to +60°C

Ex II 2 GD Ex de IIC T* Ex d e IIC T* 24 V IP 66
=PWRP+-SKT9 DXN1 2P+- 24V F 251808A 844 A1026144
LCIE99ATEX6027X IECEx LCI 09.0005X 20 A -40°C to +60°C

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2501 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2600

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Hazardous area schedule = INF + - 2502
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-100G0


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2502 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2601

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2600
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-100X7


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2600 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2602

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2601
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-200B1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2601 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2603

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2602
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-200G0


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2602 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2604

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2603
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-200S1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2603 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2605

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2604
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-201H4


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2604 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2606

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2605
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-201U3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2605 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2607

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2606
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-301B1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2606 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2608

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2607
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-301B2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2607 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2609

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2608
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-301B3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2608 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2610

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2609
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-301B4


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2609 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2611

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2610
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-301B5


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2610 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2612

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2611
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-301B6


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2611 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2613

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2612
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-302S8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2612 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2614

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2613
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-302Y2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2613 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2615

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2614
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-302Y3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2614 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2616

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2615
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303B8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2615 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2617

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2616
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303S8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2616 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2618

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2617
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303S9


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2617 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2619

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2618
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303Y1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2618 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2620

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2619
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303Y2


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2619 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2621

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2620
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303Y3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2620 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2622

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2621
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-303Y4


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2621 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2623

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2622
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-304S1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2622 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2624

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2623
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-304S6


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2623 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2625

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2624
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-305Y1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2624 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2626

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2625
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-ECP1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2625 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2627

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2626
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-ECP3


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2626 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2628

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2627
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-EJB8


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2627 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2629

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2628
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-EJB9


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2628 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2630

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2629
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-EJB17


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2629 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2631

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2630
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-P1


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2630 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2632

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2631
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-PLG9


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2631 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2633

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2632
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-SKT1A


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2632 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE 2634

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2633
0 1 2 3 4 5 6 7 8 9

Electrical inspection sheet =PWRP+-SKT9


The following checklist can be used for complete Junction boxes or for single apparatus only. Ex D Ex E Ex n Satisfactory Faulty Repaired N/A Replaced or repaired components

Apparatus is appropriate to area classification (JB / SA) X X X

Apparatus group is correct (JB / SA) X X X

Apparatus temperature class is correct (JB / SA) X X X

Apparatus circuit identification is correct (JB / SA) X X X

Apparatus circuit identification is available (JB / SA) X X X

Enclosure, glass parts and glass-to-metal sealing gaskets and/or compounds are satisfactory (JB) X X X

There are no unauthorized modifications (JB / SA) X X X

Physically check whether bolts, cable entry devices (direct and indirect) and blanking elements are of the correct type and are complete
X X X
Apparatus

and tight (JB)

Flange faces are clean and undamaged and gaskets, if any, are satisfactory (JB) X

Flange gap dimensions are within maximal values permitted (JB) X

Lamp rating, type and position are correct (SA) X X X

Electrical connections are tight (JB / SA) X X

Condition of enclosure gaskets is satisfactory X X

Enclosed-break and hermetically sealed devices are undamaged (SA) X

Restricted breathing enclosure is satisfactory (SA) X

Motor fans have sufficient clearance to enclosure and/or covers (JB / SA) X X X

Breathing and draining devices are satisfactory (JB / SA) X X X

Type of cable is appropriate X X X

There is no obvious damage to cables X X X

Sealing of trunking, ducts, pipes and/or conduits is satisfactory X X X

Stopping boxes and cable boxes are correctly filled X

Integrity of conduit system and interface with mixed system is maintained X X X

Physically check whether earthing connections, including any supplementary earthing bonding connections are satisfactory (for example
X X X
connections are tight and conductors are of sufficient cross-section)
Installation

Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactory X X X

Insulation resistance is satisfactory X X X

Automatic electrical protective devices operate within permitted limits X X X


Inspected by :
Automatic electrical protective devices are set correctly (auto-reset not possible) X X X

Special conditions of use (if applicable) are complied with X X X

Cables not in use are correctly terminated X X X Signature :


Obstructions adjacent to flameproof flanged joints are in accordance with IEC 60079-14 X

Variable voltage/frequency installation in accordance with documentation X X X


Date :
Apparatus is adequately protected against corrosion, weather, vibration and other adverse factors X X X
Enviroment

No undue accumulation of dust and dirt X X X


Unit serial no. :
Electrical insulation is clean and dry X X X

THIS DRAWING IS THE PROPERTY OF NOV ELMAR. IT MUST NOT BE ALTERED, COPIED IN ANY MEDIUM OR SHOWN TO PERMISSION
2633 PREVIOUS PAGE
AND IS SUBMITTED WITHOUT PREJUDICE TO ANY PATENTS OR DESIGNS PENDING OR TO BE APPLIED FOR BY THE COMPANY
NEXT PAGE

E1
H.Tuytelaars
P. Muilwijk A. Korevaar RELEASED TITLE : POWERPACK DATASPLIT C HIGHER LEVEL LOCATION PAGE:
12 Feb. 2015 ASSIGNMENT: DESIGNATION:

REV. ECO DRAWN CHECKED APPROVED PRINT STATUS


DRAWING No. : ES6931033721
Format: A4 PAGE MOD HTU 06.Feb.2015 PAGE DESCRIPTION : Electrical inspection sheet = INF + - 2634