Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Specifications, designs and other content appearing in this brochure are current as of August 2020 but subject to change without notice.
Designed for use in cafe and restaurants,
retail shops and small offices.
1 2
New Inverters launched Benefits of Inverter
Cooling only
Why is inverter technology economical?
Inverter system consumes less
Total cost =
the difference in initial cost.
Energy Saving This results in lower total cost. Inverters save more
energy over time
Compared with previous non-inverter series, the new RZFC-D series uses about 35% less power consumption its cooling capacity according to
for quick and effective cooling that reduces electricity bills.
the cooling load. This results in Non inverter cooling capacity
Capacity
Comparison of cooling seasonal power consumption less power consumption.
Load
On/Off operation
35%
based on average CSPF values In response to fluctuating cooling load, Non inverter air Lower efficiency Inverter cooling capacity
conditioners repeatedly perform ON (full-power)/OFF
(zero-power) operation. Inverter air conditioners, however,
100 reduction! operate at optimal cooling capacity according to the Cooling load Partial load area
power consumption
CSPF values by capacity for cassette models New inverter RZFC-D series R32 <cassette type>
CSPF 6
Previous non-inverter series R22 <cassette type>
*CSPF (cooling seasonal performance factor) is a new international
Why is inverter technology more comfortable?
Value energy-efficiency criterion calculated by methods stipulated in ISO
5 16358-1.
When temperature does not
5.13 4.90 4.90 Non inverter Inverter
4 4.67 4.67 4.67
4.29
fluctuate much, the set
4.10
3 temperature is maintained.
3.10 2.79 2.79 Inverter control responds to load changes
2 2.77 2.69 2.63 2.71 2.73
and causes minor temperature adjustments.
Non-inverter control frequently turns ON and Room
1 OFF in response to load fluctuations or load temperature Too hot
3 4
Durability Design Flexibility
Microchannel heat exchanger Coated printed circuit boards Possible to forced OFF and ON/OFF operation using external command
Microchannel technology utilises superior heat transfer (outdoor unit) *Field setting with remote controller
benefits of aluminium to create a more efficient air Coated circuit boards Round flow cassette type Duct connection middle static pressure type
conditioner. prevent problems Lighting
With a new resistance corrosion aluminium alloy, the caused by humidity
Daikin microchannel heat exchanger becomes highly and airborne dust. Interlock
durable. It also protects
A salt spray test has been conducted to demonstrate against salt contained
the corrosion-resistant capability of our products in in sea breezes.
corrosive environments for a certain period of time. Both sides of the PCB Interlock
in outdoor units are
coated.
Test of durability
- Testing organization MTEC Thailand
- Testing standard
- Result
ASTM B117
Automatic protection against
low voltage
Before testing After testing In AM and PM peak electricity consumption periods,
supply may fluctuate. Built-in low-voltage protection will
automatically cut operations. When normal voltage is Indoor units (FCFC-D, FHFC100-140D, and FBFC-D) comply with
restored, operation will resume as before. D -Net standards *FHFC40-85D requires optional adaptor to connect DIII-Net.
Normal Under
observation telescope New indoor unit
No evidence of corrosion was observed
Outdoor unit installation is
possible even with limited space
After undergoing an intensive test, the Daikin microchannel
VRV
heat exchanger is able to maintain its shape without
corrosion, which strongly confirms its durability in a highly
corrosive environment.
Adaptor not
required
Please see a video of the 100
QR m or
Micro Channel Heat space mo m or
re momre Easy connection to DIII-NET and long piping length makes
0
Exchanger test in Pattaya. 100
m 10 m or this solution suitable for projects including and SkyAir.
mo m or me
re 0 m r
50 mo
5 6
Product Lineup
Cooling only
Indoor unit FCFC40DVM4 FCFC50DVM4 FCFC60DVM4 FCFC71DVM4 FCFC85DVM4 FCFC100DVM4 FCFC125DVM4 FCFC140DVM4
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14
Indoor unit FHFC40DV14 FHFC50DV14 FHFC60DV14 FHFC71DV14 FHFC85DV14 FHFC100DV14 FHFC125DV14 FHFC140DV14
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14
DUCT CONNECTION
LOW STATIC PRESSURE
WIDTH COMPACT TYPE
NEW
DUCT CONNECTION
LOW STATIC PRESSURE
HEIGHT COMPACT TYPE
NEW
DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE
NEW
Indoor unit FBFC40DVM4 FBFC50DVM4 FBFC60DVM4 FBFC71DVM4 FBFC85DVM4 FBFC100DVM4 FBFC125DVM4 FBFC140DVM4
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14
OUTDOOR UNIT
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14
1 phase, 1 phase, 1 phase, 1 phase, 3 phase, 1 phase, 3 phase, 1 phase, 3 phase, 3 phase, 3 phase,
Power supply 220-240 / 220-230V, 220-240 / 220-230V, 220-240 / 220-230V, 220-240 / 220-230V, 380-415V, 220-240 / 220-230V, 380-415V, 220-240 / 220-230V, 380-415V, 380-415V, 380-415V,
50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz 50Hz 50 / 60Hz 50Hz 50 / 60Hz 50Hz 50Hz 50Hz
7 8
CEILING MOUNTED CASSETTE TYPE Round Flow
Outdoor unit
Power supply Outdoor unit
Cooling Capacity 1,2
FCFC40DVM4
RZFC40DVM4
4.0
FCFC50DVM4
RZFC50DVM4
5.0
FCFC60DVM4
RZFC60DVM4
6.0
FCFC71DVM4
RZFC71DVM4
1 Phase, 220–240 / 220-230V, 50 / 60Hz
7.1
FCFC85DVM4
RZFC85DVM4
8.5
FCFC100DVM4
RZFC100DVM4
10.0
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2)
FCFC40/50/60/71/85/100/125/140DVM4 Btu/h
13,600
(6,100-15,400)
17,100
(7,800-19,100)
20,500
(8,900-21,500)
24,200
(10,900-27,300)
29,000
(14,300-34,100)
34,100
(17,100-38,200)
Power consumption Cooling 1 kW 1.26 1.57 1.89 2.38 2.85 3.35
COP kW/kW 3.18 2.98
CSPF Wh/Wh 5.13 4.90 4.67
Indoor unit Colour Unit White
Decoration panel Fresh white
Airflow rate m /min 3
19 / 14 / 11 23 / 18 / 13 34 / 27 / 20
(H / M / L) cfm 671 / 494 / 388 812 / 635 / 459 1,200 / 953 / 706
Sound pressure level (H / M / L) dB(A)
3
37 / 32 / 28 37 / 34 / 28 38 / 34 / 29 45 / 38 / 33
Dimensions Unit mm 256X840X840 298X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 19 22 24
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level 3 Cooling dB(A) 48 49 50 51 52
Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
Max. installation level difference m 15 30
Option Wireless remote controller Heat insulation Both liquid and gas piping
A signal receiver must be added to the indoor unit.
Accessory required for indoor unit.
Cooling only
Simplified Remote Controller SPECIFICATION ( 3 Phase )
(Wired Remote Controller) BRC7F635F 71 85 100 125 140
NEW Indoor unit FCFC71DVM4 FCFC85DVM4 FCFC100DVM4 FCFC125DVM4 FCFC140DVM4
Model
BRC2E61 Signal receiver unit
Name Outdoor unit RZFC71DY14 RZFC85DY14 RZFC100DY14 RZFC125DY14 RZFC140DY14
(Installed type) Power supply Outdoor unit 3 Phase, 380-415V, 50Hz
Note: Remote controller cable is not included Cooling Capacity 1,2 7.1 8.5 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
and must be obtained locally.
Wireless remote controller is supplied
in a set with a signal receiver. 24,200 29,000 34,100 42,700 47,800
Btu/h (10,900-27,300) (14,300-34,100) (17,100-38,200) (19,500-47,800) (21,200-52,900 )
Power consumption Cooling 1
kW 2.38 2.85 3.35 4.70 5.88
COP kW/kW 2.98 2.66 2.38
(Including filter chamber) (Colorimetric method 90%) KAF557D80 KAF557D160 Dimensions (HXWXD) mm 695X930X350 990X940X320
Machine weight kg 46 62
(Colorimetric method 65%) KAF552D80 KAF552D160
6 Replacement high-efficiency filter 5 Certified Operation range °CDB 21 to 46
(Colorimetric method 90%) KAF553D80 KAF553D160 Piping Liquid (Flare) mm 9.5
7 Filter chamber KDDFP55C160 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
8 Replacement long-life filter KAF5511D160
Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
9 Ultra long-life filter unit (Including filter chamber) KAF555D160 Max. interunit piping length m 50 (Equivalent length 70)
10 Replacement ultra long-life filter 5 KAF550D160 Max. installation level difference m 30
Heat insulation Both liquid and gas piping
11 Branch duct chamber KDJP55C80 KDJP55C160
12 Insulation kit for high humidity 6 KDTP55K80A KDTP55K160A Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
Note: When installing a fresh air intake kit (chamber type), two air outlet corners are closed.
1 3
The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. 2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
2
It is recommended that the volume of outdoor air introduced through the kit is limited to 10% The chamber type is recommended when more fresh air is necessary. 3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the 4
Please order using the names of both components instead of set name.
operating sound and may also influence temperature sensing. 5
Filter chamber is required.
6
Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.
9 10
CEILING SUSPENDED TYPE
BRC2E61 Btu/h
24,200
(10,900-27,300)
29,000
(14,300-34,100)
34,100
(17,100-38,200)
42,700
(19,500-47,800)
47,800
(21,200-52,900 )
Power consumption Cooling 1 kW 2.50 2.99 3.52 4.88 6.07
Note: Remote controller cable is not COP kW/kW 2.84 2.56 2.31
included and must be obtained CSPF Wh/Wh 4.09 3.82 3.71
locally. Signal receiver unit (Installed type) Signal receiver unit (Installed type) Colour Unit White
Indoor unit
Wireless remote controller is supplied in a Wireless remote controller is supplied in a Airflow rate m3/min 24 / --- / 20 30 / --- / 25 28 / 24 / 20 31 / 27 / 23 34 / 29 / 24
set with a signal receiver. set with a signal receiver. (H / M / L) cfm 847/ --- / 706 1,059 / --- / 883 988 / 847 / 706 1,094 / 953 / 812 1,200 / 1,024 / 847
Sound pressure level 3 (H / M / L) dB(A) 42 / --- / 37 44 / --- / 39 42 / 38/ 34 44 / 41 / 37 46 / 42 / 38
Dimensions (HXWXD) Unit mm 195X1,400X680 195X1,590X680 235X1,590X690
Option List Machine weight Unit kg 32 35 38
Kit name Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
FHFC100DV14
No. Name of option Remark FHFC40DV14 unit Coil Type Micro channel
FHFC60DV14 FHFC71DV14 FHFC85DV14 FHFC125DV14
FHFC50DV14 Compressor Type Hermetically sealed swing type
FHFC140DV14
Motor output kW 1.60 2.40
1 Replacement long-life filter Resin net KAFJ501D56 KAFJ501D80 KAFJ501D112 KAFJ501D160 KAF501B160 Refrigerant charge (R32) kg 1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
2 Fresh air intake kit -------- KDDQ50A140 Sound pressure level 3 Cooling dB(A) 50 51 52 54 56
Dimensions (HXWXD) mm 695X930X350 990X940X320
3 Drain pump kit KDU50N60VE KDU50N125VE KDU50R160
Machine weight kg 46 62
4 L-type piping kit (for upward direction) KHFP5M63 KHFP5M160 KHFP5N160 Certified Operation range °CDB 21 to 46
5 Remote controller Wireless type Cooling only BRC7EA66 BRC7GA56 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
6 Simplified remote controller Wired type 1 BRC2E61
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
7 Central remote controller DCS302CA61 2 DCS302CA61 3 Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
8 Unified ON/OFF controller DCS301BA61 2 DCS301BA61 3 Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
9 Schedule timer DST301BA61 2 DST301BA61 3
Heat insulation Both liquid and gas piping
10 intelligent Touch Controller DCS601C51 2 DCS601C51 3
Note :
11 Adaptor for wiring BRP11B61 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
12 Wiring adaptor for electrical appendices 4 KRP4AA52 3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
13 Installation box for adaptor PCB KRP1CA93 KRP1D93A
14 Interface adaptor for SkyAir series DTA112BA51 --------
15 Remote sensor (for indoor temperature) BRCS01A-1 BRCS01A-4
16 Electrical box with earth terminal (3 blocks) KJB311AA
17 Electrical box with earth terminal (2 blocks) KJB212AA
Note: 1Wiring for wired remote controller should be obtained locally.
2
This optional accessory requires DTA112BA51.
3
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
4
Installation box for adaptor PCB (KRP1CA93, KRP1D93A) is necessary.
11 12
DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
Model
Indoor unit
40
FDBF40DV14
50
FDBF50DV14
60
FDBF60DV14
71
FDBF71DV14
85
FDBF85DV14
Name Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC85DVM4
Power supply Indoor unit ----------
Outdoor unit 1 Phase, 220-240V, 50Hz
NEW Cooling Capacity 1,2
kW
4.0 5.0 6.0 7.1 8.5
Rated (Min. - Max.) (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0)
FDBF40/50/60/71/85DV14 Btu/h
13,600
(6,100-15,400)
17,100
(7,800-19,100)
20,500
(8,900-21,500)
24,200
(10,900-27,300)
29,000
(14,300-34,100)
Power consumption Cooling 1
kW 1.19 1.56 2.07 2.37 2.98
COP W/W 3.35 3.20 2.90 3.00 2.85
CSPF Wh/Wh 4.38 4.13 4.13 3.93 3.93
Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 15 / 12 / 9.5 22.5 / 20 / 17.5
cfm 530 / 424 / 335 794 / 706 / 618
External static pressure 3 Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 37 / 33 / 25 39 / 35 / 33
Air filter5 ----------
Dimensions (HXWXD) mm 245X700X800 245X1,000X800
Machine weight kg 26 36
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level Cooling
4
dB(A) 48 49 50 51
Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9
Option Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
kW
(10,900-27,300)
2.37
(14,300-34,100)
2.98
COP W/W 3.00 2.85
CSPF Wh/Wh 3.93 3.93
Enables selection of right or left piping at installation site Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 22.5 / 20 / 17.5
cfm 794 / 706 / 618
External static pressure 3 Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 39 / 35 / 33
Air filter 5 ----------
Dimensions (HXWXD) mm 245X1,000X800
Machine weight kg 36
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
Can unit Coil Type Micro channel
select! Compressor Type Hermetically sealed swing type
Motor output kW 1.60 1.60 2.40
For left side For right side
Refrigerant charge (R32) kg 1.0 (Charged for 15 m)
connection connection
Sound pressure level 4 Cooling dB(A) 50 51
Dimensions (HXWXD) mm 695X930X350
Machine weight kg 46
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
Option List connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Kit name
Outdoor unit mm 18.0 (Hole)
No. Name of option Remark FDBF40DV14 FDBF71DV14 Max. interunit piping length m 50 (Equivalent length 70)
FDBF50DV14 FDBF85DV14
FDBF60DV14 Max. installation level difference m 30
Heat insulation Both liquid and gas piping
1 Remote controller Wireless type Cooling BRC4C66
Note :
2 Simplified Remote Controller Wired type 1 BRC2E61 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3 Remote sensor (for indoor temperature) BRCS01A-1
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
Note: 1Wiring for wired remote controller should be obtained locally. 4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.
13 14
DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE
15 16
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
greater flexibility
Model
Name Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC85DVM4 RZFC100DVM4
Power supply Indoor unit ----------
Outdoor unit 1 Phase, 220–240 / 220-230V, 50 / 60Hz
Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5 10.0
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2)
13,600 17,000 20,500 24,200 29,000 34,100
NEW Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100) (17,100-38,200)
Power consumption Cooling 1 kW 1.19 1.56 2.07 2.37 2.74 3.17
FBFC40/50/60/71/85/ COP W/W 3.35 3.20 2.90 3.00 3.10 3.15
100/125/140DVM4 CSPF
Indoor unit Colour
Wh/Wh 4.38 4.18 4.18
----------
3.98 3.98 3.98
17 18
OUTDOOR UNIT REMOTE CONTROLLER Optional accessory
Operation mode
RZFC40DVM4
RZFC85DVM4
RZFC100DVM4 Simple operation selection Temperature
RZFC50DVM4 RZFC71DY14 Using only six buttons, users have direct access to basic setting (+/-)
RZFC60DVM4 RZFC85DY14 RZFC125DY14 functions. Airflow rate
RZFC71DVM4 RZFC100DY14 RZFC140DY14 This enables them to easily set comfort to their preference. (Fan speed)
Facilitates pump down (Refrigerant recovery function) Low gas pressure detection function Overseas guests at hotels to understand functions Children and elderly users at home to operate without
A pump-down switch is provided to make it easier to collect Effective gas monitoring reduces the labor required for without having to know a foreign language. having to read difficult and hard-to-see commands.
refrigerant if the unit is to be moved or layout modified. operation, maintenance, and repairs.
*Pump-down function is available for pre-charged refrigerant amount. Compact
*Although pumping-down operation allows most of the refrigerant to be
recovered in a short period of time, some refrigerant will remain inside Measuring only 85 x 85 mm, the new remote controller is
the indoor unit and refrigerant piping. extremely compact and complements any interior design.
Using a refrigerant recovery machine, recover remaining refrigerant from
the stop valve service port until the pressure falls to 0.09 MPa. (gauge
pressure:-0.011MPa) or less. 35
Reduced size mm
1 Swing compressor
High efficiency during partial load operation. 120 mm 85 mm 70 mm
3
Conventional BRC2E61 Conventional simplified
remote controller remote controller
Energy savings is realised, Swing bushing
Refrigerant gas
eliminating the friction and the 2
leakage of refrigerant gas.
Piston by incorporated 4
Wireless remote controller
blade and roller.
1 BRC7F635F BRC7GA56 The wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit of installed type is contained inside decoration panel or indoor unit.
2 Refrigerant cooling (RZFC71-140DY14) Shape of signal receiver unit differs according to the indoor unit.
Daikin’s unique refrigerant cooling system exhibits Signal receiver unit Signal receiver unit
Wireless remote controller for each indoor unit type
(Installed type) (Installed type)
high cooling capacity even during high outdoor Cooling only
temperatures. Refrigerant cooling helps protect
the printed circuit board and BRC7EA66 BRC4C66 CEILING MOUNTED CASSETTE TYPE
40-85
BRC7F635F
BRC7EA66
maintains high cooling capacity CEILING SUSPENDED TYPE
100-140 BRC7GA56
even during high outdoor DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
temperatures. Signal receiver unit DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE BRC4C66
Signal receiver unit
(Installed type) (Separate type) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
4 Fan LCD panel shows operating status in letters, numbers, and motion.
V-cut Propeller Fan (RZFC40-100DVM4/Y14) Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Through use of a V-cut propeller fan that imitates the Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
efficiency of the swan, a migratory bird, airflow becomes Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
V-cut propeller fan Imitating the performance Programming time display
smooth and loss is reduced. when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
of the swan
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.
19 20
REMOTE CONTROLLER Optional accessory
For simultaneous
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Centralised control of
Centralised remote up to 64 indoor groups
control from remote location
up to 1 km away.
Interface adapter for SkyAir series (option) is Interface adapter for SkyAir series (option) is
*Except for FDBF and FDLF required (See note 3) required (See note 3)
Note: 1BRC2E61 can connect to BRC2E61 only. 2When a wireless remote controller is used, it is not possible to use 2 wireless remote controllers. Combination of BRC2E61
(main) and wireless remote controller (sub) is available. 3FHFC40-85D requires interface adaptor for SkyAir series.
Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.
Interface adaptor for SkyAir series Enables centralised control via connection to a The interface adaptor for SkyAir series is required for
high-speed, DIII-NET communication system, Ceiling suspended type 40-85 class.
DTA112BA51 (Option) adopted for the Daikin system.
Necessary for interface adaptor for SkyAir series with the central remote control
units shown at above.
21 22
FUNCTIONS
overview
Cooling only Indoor unit FCFC40-140DVM4 FHFC40-85DV14 FHFC100-140DV14 FDBF40-85DV14 FDLF40-85DV14 FBFC40-140DVM4
Remote Wired BRC2E61 ------- BRC2E61 ------- BRC2E61 ------- BRC2E61 ------- BRC2E61 ------- BRC2E61 -------
controller
Wireless ------- BRC7F635F ------- BRC7EA66 ------- BRC7GA56 ------- BRC4C66 ------- BRC4C66 ------- BRC4C66
1 ON / OFF timer 1
2 Auto swing 2
4 DC fan motor 4
Comfort
5 Switchable fan speed 5 3 step 3 step 3 step 3 step 3 step 3 step
3 step 3 step 2 step 2 step 3 step 3 step
*3 *3 *3
12 Drain pump mechanism 12
13 Pre-charged for up to 10 / 15 m *1 13
14 Long-life filter 14 *3
Work &
Servicing 15 Filter sign 15
17 Emergency operation *4 *4 *4 17 *4 *4 *4
18 Self-diagnosis function 18
19 Auto-restart 19
27 High-efficiency filter 27
Note:
*1: For outdoor units. *2: Wiring adaptor for electrical appendices (and installation box) is necessary. *3: Option is requied. *4: For outdoor unit RZFC-DY14 only. *5: It is not possible to use 2 wireless remote controllers. Combination of BRC2E61 (main) and wireless remote controller (sub) is available.
23 24
Product Lineup
Series 25 35 50 60 71 100 125 140
CEILING MOUNTED
CASSETTE TYPE
Round Flow
DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE
OUTDOOR UNIT
Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14
OUTDOOR UNIT
25 26
CEILING MOUNTED CASSETTE TYPE Round Flow
SPECIFICATION (3 Phase)
FCQ50/6071/100/125/140KA COP W/W 3.40 2.85 3.40 2.85 3.40 2.85 3.40 2.85
Indoor Airflow rate (H/M/L) m3/min 33/28/22.5 21/17.5/13.5 33/28/22.5 21/17.5/13.5
unit cfm 1,165/988/794 741/618/477 1,165/988/794 741/618/477
Sound pressure level 3 (H/M/L) dB(A) 44/39/34 44/40/36 35/31.5/28 44/39/34 44/40/36 35/31.5/28
Dimensions Unit mm 298X840X840 256X840X840 298X840X840 256X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 24 21 24 21
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Coil Type Cross fin coil
unit Compressor Type Hermetically sealed scroll type
Motor output kW 2.4 3.1 2.4 3.1 2.4 3.1 2.4 3.1
Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7 (Charged for 30 m)
Sound pressure Cooling dB(A) 50
level3 Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Dimensions (HXWXD) mm 1,170X900X320
Machine weight kg 97
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP25 (I.DØ25XO.D Ø32)
Outdoor unit mm Ø26.0 (Hole)
Accessory required for indoor unit. Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Navigation Remote Controller Wired LCD Remote Controller Wireless LCD remote controller Note :
(Wired Remote Controller) A signal receiver must be added to the indoor unit. 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
BRC7F635F
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
27 28
CEILING MOUNTED
COMPACT MULTI FLOW CASSETTE TYPE
RKS25AVMG4
35
FFQ35BV1B4
RKS35AVMG4
50
FFQ50BV1B4
RKS50AVMG4
60
FFQ60BV1B4
RKS60AVMG4
BRC7E531W
Signal receiver unit
(Installed type)
Wireless remote
controller is supplied
in a set with a signal
receiver.
FEATURES
SIZED TO FIT INSIDE 600mm WIDE CEILING GRIDS QUIET, SMALL-DIAMETER FAN CONSISTENT COMFORT THROUGHOUT
29 30
CEILING SUSPENDED TYPE
BRC7GA56
BRC1E63 BRC1C61
Note: Remote controller cable is not Note: Remote controller cable is not
included and must be included and must be
obtained locally. obtained locally. Signal receiver unit (Installed type)
Wireless remote controller is supplied
Option List
in a set with a signal receiver. Kit name
Name of option Remark
FHQ50DAVM4 FHQ60DAVM4 FHQ71DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4
Replacement long-life filter Resin net KAFP501A56 KAFP501A80 KAFP501A160
FEATURES Fresh air intake kit KDDQ50A140
Drain pump kit KDU50P140VE
SOPHISCATED DESIGN AUTO SWING & LOUVERS SUITABLE FOR HIGH CEILINGS L-type piping kit (for upward direction) KHFP5N160
Remote controller Wireless type Cooling only BRC7GA56
Wired type1 BRC1C61
FLEXIBLE INSTALLATION NON FLOCKING FLAP QUIET OPERATION Navigation Remote Controller Wired type1 BRC1E62
Central remote controller DCS302CA61
Unified ON/OFF controller DCS301BA61
Schedule timer DST301BA61
SPECIFICATION (1 Phase) intelligent Touch Controller2 DCS601C51
50 60 71 100 125 140 100 125 140 Wiring adaptor for electrical appendices KRP1BA54
FHQ50DAVM4 FHQ60DAVM4 FHQ71DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4 Wiring adaptor for electrical appendices3 KRP4AA52
Model Indoor unit
Installation box for adaptor PCB KRP1D93A
Name Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MVM4 RZR125MVM4 RZR140MVM4 RZR100MYM4 RZR125MYM4 RZR140MYM4 Adaptor box mounting plate KKSAP50A56 ----------
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Remote sensor (for indoor temperature) KRCS01-4B
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0 Electrical box with earth terminal (3 blocks) KJB311AA
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0)
Rated (Min. - Max.) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) Electrical box with earth terminal (2 blocks) KJB212AA
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 Note: 1Wiring for wired remote controller to be procured locally.
Btu/h (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800)
(21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) 2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Cooling1 kW 1.24 1.58 2.37 3.03 4.42 Installation box for adaptor PCB(KRP1D93A) is necessary.
Power consumption 5.55 3.03 4.42 5.55
COP W/W 4.03 3.80 3.00 3.30 2.83 2.52 3.30 2.83 2.52
Airflow rate (H/M/L) m3/min 15/12/10 20.5/17/14 28/24/20 31/27/23 34/29/24 28/24/20 31/27/23 34/29/24
Indoor
cfm 530/424/353 724/600/494 988/847/706 1,094/953/812 1,200/1,024/847 988/847/706 1,094/953/812 1,200/1,024/847
unit 3
Sound pressure level (H/M/L) dB(A) 37/35/32 38/36/34 42/38/34 44/41/37 46/42/38 42/38/34 44/41/37 46/42/38
Dimensions (HXWXD) mm 235X960X690 235X1,270X690 235X1,590X690
Machine weight kg 25 32 38
Certified operation range °CWB 14 to 25
Coil Type Cross fin coil Micro channel
Outdoor
unit Compressor Type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9(Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
level3 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight kg 43 65 73
Certified operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP20 (I.D Ø20XO.D Ø26)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
31 32
WALL MOUNTED TYPE
BRC1E63
Note: Remote controller cable is not
included and must be obtained
locally.
Option List
Kit name
Name of option Remark
FAQ100CVEA4
Drain-up kit K-KDU572EVE
Remote controller Wireless type Cooling only BRC7EB519
Wired type1 BRC1C61
Wired LCD Remote Controller Navigation Remote Controller
Remote sensor (for Indoor temperature)
Wired type1 BRC1E62
KRCS01-4B
Central remote controller2 DCS302CA61
Unified ON/OFF controller2 DCS301BA61
Schedule timer2 DST301BA61
BRC1C61 intelligent Touch Controller2 DCS601C51
Note: Remote controller cable is not
Wiring adaptor for electrical appendices3 KRP4AA51
included and must be obtained Installation box for adaptor PCB KRP4AA93
locally. Electrical box with earth terminal (3 blocks) KJB311AA
Electrical box with earth terminal (2 blocks) KJB212AA
Noise filter ( For electromagnetic interface use only) KEK26-1A
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA93) is necessary.
BRC7EB519
FEATURES
COMPACT & SOPHISCATED DESIGN AUTO SWING & WIDE-ANGEL LOUVERS COMFORT EVEN ON THE FAR SIDE OF THE ROOM
33 34
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE
installation flexibility
Name Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MVM4 RZR125MVM4 RZR140MVM4 RZR100MYM4 RZR125MYM4 RZR140MYM4
Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz
Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4)
Rated (Min. - Max.)
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800
Btu/h
FBQ50/60/71/100/125/140E Power consumption Cooling1 kW
(7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600)
1.39 1.69 2.22 2.82 4.58 5.85 2.82 4.58 5.85
COP W/W 3.60 3.56 3.20 3.55 2.73 2.39 3.55 2.73 2.39
CSPF Wh/Wh 5.40 5.20 5.04 4.73 4.61 4.38 4.73 4.61 4.38
Indoor Colour ----------
unit Fan Airflow rate (H/M/L) m3/min 18/15/12.5 23/19.5/16 32/27/22.5 36/30.5/25 32/27/22.5 36/30.5/25
cfm 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 1,130/953/794 1,271/1,077/883
External static pressure3 Pa Rated 50 (50-150)
Sound pressure level4 (H/M/L) dB(A) 35/33/31 38/35/33 38/35.5/33 40/37.5/35 38/35.5/33 40/37.5/35
Air filter5 ----------
Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800
Machine weight kg 37 47
Certified Operation range °CWB 14 to 25
Colour Ivory white
Outdoor
unit Coil Type Cross fin coil Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9(Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
level4 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight kg 43 65 73
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP25 (I.DØ25XO.D Ø32)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Accessory required for indoor unit. Both liquid and gas piping
Heat insulation
Navigation Remote Controller Wired LCD Remote Controller Wireless LCD remote controller
(Wired Remote Controller) A signal receiver must be added to the indoor unit.
35 36
FLOOR STANDING TYPE
SPECIFICATION (1 Phase)
BRC1E63
can be SPECIFICATION (3 Phase)
incorporated 125 140 125 140 125 140 125 140
into the Model Indoor unit FVQ125CVEB4 FVQ140CVEB4 FVQ60CVE4x2 FVQ71CVEB4x2 FVQ125CVEB4 FVQ140CVEB4 FVQ60CVE4x2 FVQ71CVEB4x2
indoor unit. Name Outdoor unit RZR125LVVM4 RZR140LVVM4 RZR125LVVM4 RZR140LVVM4 RZR125LUY14 RZR140LUY14 RZR125LUY14 RZR140LUY14
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 12.5 13.5 12.5 13.5 12.5 13.5 12.5 13.5
kW
Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
42,700 46,100 42,700 46,100 42,700 46,100 42,700 46,100
Btu/h
(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
Power consumption Cooling1 kW 4.39 5.40 4.39 5.40 4.39 5.40 4.39 5.40
COP W/W 2.85 2.50 2.85 2.50 2.85 2.50 2.85 2.50
Indoor Fan Airflow rate (H/M/L) m3/min 28/26/24 30/28/26 18/16/14 28/26/24 30/28/26 18/16/14
unit cfm 988/918/847 1,059/988/918 635/565/494 988/918/847 1,059/988/918 635/565/494
3
Sound pressure level (H/M/L) dB(A) 51/48/46 53/51/48 43/41/38 51/48/46 53/51/48 43/41/38
Dimensions (HXWXD) mm 1,850X600X350 1,850X600X270 1,850X600X350 1,850X600X270
Machine weight kg 47 39 47 39
Certified Operation range °CWB 14 to 25
Accessory required for indoor unit. Coil Type Cross fin coil
Outdoor
unit Compressor Type Hermetically sealed scroll type
Motor output kW 2.4 3.1 2.4 3.1 2.8 3.4 2.8 3.4
Navigation Remote Controller Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7 (Charged for 30 m)
(Wired Remote Controller) Sound pressure Cooling dB(A) 50
level3
Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Dimensions (HXWXD) mm 1,170X900X320
BRC1E63 Machine weight kg 97
Note: Remote controller cable is not Certified Operation range °CDB 21 to 46
included and must be procured Piping Liquid (Flare) mm Ø9.5
locally. connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP20 (I.DØ20XO.D Ø26)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
37 38