DIDSI2009

Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the user's manual carefully before using this product. The user's manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

AIR CONDITIONING SYSTEM


Cautions on product corrosion COOLING ONLY [50Hz]
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.

• SERVICE AND SPARE PARTS : Jakarta Selatan, Telp. : 021-2782 5545


Cirebon, Telp. : 0231-880 2760 | Samarinda, Telp. : 0541-252 2889 | Banjarmasin, Tlp. : 0511-326 8168
• TRAINING CENTER : Sunter, Telp. : 021-650 5028 • BRANCH : Bekasi, Telp. :021-2945 0585
Tangerang, Telp. : 021-5314 1195 | Bandung, Telp. : 022-522 5150 | Semarang, Telp. : 024-7660 3221
Yogyakarta, Telp. : 0274-551 321 | Surabaya, Telp. : 031-503 1138 | Denpasar, Telp. : 0361-900 5514
Makassar, Telp. : 0411-805 2691 | Palembang, Telp. : 0711-573 2282 | Pekanbaru, Telp. : 0761-561 139
Medan, Telp. : 061-4200 8866 | Manado, Telp. : 0341-719 1199

Specifications, designs and other content appearing in this brochure are current as of August 2020 but subject to change without notice.
Designed for use in cafe and restaurants,
retail shops and small offices.

Daikin’s SkyAir series delivers superior comfort


and energy performance
for both occupants and building owners.

1 2
New Inverters launched Benefits of Inverter
Cooling only
Why is inverter technology economical?
Inverter system consumes less

unit price + cost of electricity


electricity, and soon recovers Non inverter Inverter

Total cost =
the difference in initial cost.
Energy Saving This results in lower total cost. Inverters save more
energy over time

Recovery point Time

Throughout the cooling season,


Daikin’s new inverter models reduce energy consumption Inverter air conditioner can adjust Rated condition

Compared with previous non-inverter series, the new RZFC-D series uses about 35% less power consumption its cooling capacity according to
for quick and effective cooling that reduces electricity bills.
the cooling load. This results in Non inverter cooling capacity

Capacity
Comparison of cooling seasonal power consumption less power consumption.

Load
On/Off operation

35%
based on average CSPF values In response to fluctuating cooling load, Non inverter air Lower efficiency Inverter cooling capacity
conditioners repeatedly perform ON (full-power)/OFF
(zero-power) operation. Inverter air conditioners, however,
100 reduction! operate at optimal cooling capacity according to the Cooling load Partial load area
power consumption

cooling load. Since inverter air conditioners provide required


Cooling seasonal

minimum cooling capacity with minimum electrical power, 0


total power consumption can be reduced during cooling period. 35
Outdoor ambient temperature (°C)
65
Inverters operate without repeated ON/OFF operation.
Inverter Highway driving Non inverter City driving
Note: Value 100 represents the amount of electricity used by a
non-inverter model during a similar annual cooling period. Continuous driving Stop, go, stop ... Constantly stopping
without stopping and starting
Previous non-inverter series New inverter RZFC-D series and starting is consumes energy and
(average) (average) more fuel efficient. is less fuel efficient.
(cassette type) (cassette type)

CSPF values by capacity for cassette models New inverter RZFC-D series R32 <cassette type>

CSPF 6
Previous non-inverter series R22 <cassette type>
*CSPF (cooling seasonal performance factor) is a new international
Why is inverter technology more comfortable?
Value energy-efficiency criterion calculated by methods stipulated in ISO
5 16358-1.
When temperature does not
5.13 4.90 4.90 Non inverter Inverter
4 4.67 4.67 4.67
4.29
fluctuate much, the set
4.10
3 temperature is maintained.
3.10 2.79 2.79 Inverter control responds to load changes
2 2.77 2.69 2.63 2.71 2.73
and causes minor temperature adjustments.
Non-inverter control frequently turns ON and Room
1 OFF in response to load fluctuations or load temperature Too hot

mismatch and causes large temperature Large


0 swings.
temperature
fluctuation
RZFC40 RZFC50 RZFC60 RZFC71 RZFC85 RZFC100 RZFC125 RZFC140
Inverter Set
DVM4 DVM4 DVM4 DVM4 / Y14 DVM4 / Y14 DVM4 / Y14 DY14 DY14 temperature
Non inverter
Comfortable
Non Inverter R35GV1 R18NUV1 R21NUV1 R26NUV1 / Y1 R30NUV1 / Y1 R36NUV1 / Y1 R42NUY1 R48NUY1
Small
temperature
fluctuation
Inverter
What is CSPF? Non inverter
Too cold Too cold
CSPF is the value for the annual total cooling load divided by the annual total power consumption at outdoor
air conditions specified by ISO standard. Time

3 4
Durability Design Flexibility
Microchannel heat exchanger Coated printed circuit boards Possible to forced OFF and ON/OFF operation using external command
Microchannel technology utilises superior heat transfer (outdoor unit) *Field setting with remote controller

benefits of aluminium to create a more efficient air Coated circuit boards Round flow cassette type Duct connection middle static pressure type
conditioner. prevent problems Lighting
With a new resistance corrosion aluminium alloy, the caused by humidity
Daikin microchannel heat exchanger becomes highly and airborne dust. Interlock
durable. It also protects
A salt spray test has been conducted to demonstrate against salt contained
the corrosion-resistant capability of our products in in sea breezes.
corrosive environments for a certain period of time. Both sides of the PCB Interlock
in outdoor units are
coated.
Test of durability
- Testing organization MTEC Thailand
- Testing standard
- Result
ASTM B117
Automatic protection against
low voltage
Before testing After testing In AM and PM peak electricity consumption periods,
supply may fluctuate. Built-in low-voltage protection will
automatically cut operations. When normal voltage is Indoor units (FCFC-D, FHFC100-140D, and FBFC-D) comply with
restored, operation will resume as before. D -Net standards *FHFC40-85D requires optional adaptor to connect DIII-Net.

Normal Under
observation telescope New indoor unit
No evidence of corrosion was observed
Outdoor unit installation is
possible even with limited space
After undergoing an intensive test, the Daikin microchannel
VRV
heat exchanger is able to maintain its shape without
corrosion, which strongly confirms its durability in a highly
corrosive environment.

Adaptor not
required
Please see a video of the 100
QR m or
Micro Channel Heat space mo m or
re momre Easy connection to DIII-NET and long piping length makes
0
Exchanger test in Pattaya. 100
m 10 m or this solution suitable for projects including and SkyAir.
mo m or me
re 0 m r
50 mo

5 6
Product Lineup
Cooling only

40 50 60 71 85 100 125 140


CEILING MOUNTED
CASSETTE TYPE
Round Flow

Indoor unit FCFC40DVM4 FCFC50DVM4 FCFC60DVM4 FCFC71DVM4 FCFC85DVM4 FCFC100DVM4 FCFC125DVM4 FCFC140DVM4
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14

CEILING SUSPENDED TYPE

Indoor unit FHFC40DV14 FHFC50DV14 FHFC60DV14 FHFC71DV14 FHFC85DV14 FHFC100DV14 FHFC125DV14 FHFC140DV14
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14

DUCT CONNECTION
LOW STATIC PRESSURE
WIDTH COMPACT TYPE
NEW

Indoor unit FDBF40DV14 FDBF50DV14 FDBF60DV14 FDBF71DV14 FDBF85DV14


Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14

DUCT CONNECTION
LOW STATIC PRESSURE
HEIGHT COMPACT TYPE
NEW

Indoor unit FDLF40DV14 FDLF50DV14 FDLF60DV14 FDLF71DV14 FDLF85DV14


Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14

DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE
NEW

Indoor unit FBFC40DVM4 FBFC50DVM4 FBFC60DVM4 FBFC71DVM4 FBFC85DVM4 FBFC100DVM4 FBFC125DVM4 FBFC140DVM4
Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14

OUTDOOR UNIT

Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC71DY14 RZFC85DVM4 RZFC85DY14 RZFC100DVM4 RZFC100DY14 RZFC125DY14 RZFC140DY14
1 phase, 1 phase, 1 phase, 1 phase, 3 phase, 1 phase, 3 phase, 1 phase, 3 phase, 3 phase, 3 phase,
Power supply 220-240 / 220-230V, 220-240 / 220-230V, 220-240 / 220-230V, 220-240 / 220-230V, 380-415V, 220-240 / 220-230V, 380-415V, 220-240 / 220-230V, 380-415V, 380-415V, 380-415V,
50 / 60Hz 50 / 60Hz 50 / 60Hz 50 / 60Hz 50Hz 50 / 60Hz 50Hz 50 / 60Hz 50Hz 50Hz 50Hz

7 8
CEILING MOUNTED CASSETTE TYPE Round Flow

Cassette air conditioner with 360° SPECIFICATION ( 1 Phase )


40 50 60 71 85 100

uniform airflow sets the standard Model


Name
Indoor unit

Outdoor unit
Power supply Outdoor unit
Cooling Capacity 1,2
FCFC40DVM4
RZFC40DVM4

4.0
FCFC50DVM4
RZFC50DVM4

5.0
FCFC60DVM4
RZFC60DVM4

6.0
FCFC71DVM4
RZFC71DVM4
1 Phase, 220–240 / 220-230V, 50 / 60Hz
7.1
FCFC85DVM4
RZFC85DVM4

8.5
FCFC100DVM4
RZFC100DVM4

10.0
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2)

FCFC40/50/60/71/85/100/125/140DVM4 Btu/h
13,600
(6,100-15,400)
17,100
(7,800-19,100)
20,500
(8,900-21,500)
24,200
(10,900-27,300)
29,000
(14,300-34,100)
34,100
(17,100-38,200)
Power consumption Cooling 1 kW 1.26 1.57 1.89 2.38 2.85 3.35
COP kW/kW 3.18 2.98
CSPF Wh/Wh 5.13 4.90 4.67
Indoor unit Colour Unit White
Decoration panel Fresh white
Airflow rate m /min 3
19 / 14 / 11 23 / 18 / 13 34 / 27 / 20
(H / M / L) cfm 671 / 494 / 388 812 / 635 / 459 1,200 / 953 / 706
Sound pressure level (H / M / L) dB(A)
3
37 / 32 / 28 37 / 34 / 28 38 / 34 / 29 45 / 38 / 33
Dimensions Unit mm 256X840X840 298X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 19 22 24
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level 3 Cooling dB(A) 48 49 50 51 52
Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
Max. installation level difference m 15 30
Option Wireless remote controller Heat insulation Both liquid and gas piping
A signal receiver must be added to the indoor unit.
Accessory required for indoor unit.
Cooling only
Simplified Remote Controller SPECIFICATION ( 3 Phase )
(Wired Remote Controller) BRC7F635F 71 85 100 125 140
NEW Indoor unit FCFC71DVM4 FCFC85DVM4 FCFC100DVM4 FCFC125DVM4 FCFC140DVM4
Model
BRC2E61 Signal receiver unit
Name Outdoor unit RZFC71DY14 RZFC85DY14 RZFC100DY14 RZFC125DY14 RZFC140DY14
(Installed type) Power supply Outdoor unit 3 Phase, 380-415V, 50Hz
Note: Remote controller cable is not included Cooling Capacity 1,2 7.1 8.5 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
and must be obtained locally.
Wireless remote controller is supplied
in a set with a signal receiver. 24,200 29,000 34,100 42,700 47,800
Btu/h (10,900-27,300) (14,300-34,100) (17,100-38,200) (19,500-47,800) (21,200-52,900 )
Power consumption Cooling 1
kW 2.38 2.85 3.35 4.70 5.88
COP kW/kW 2.98 2.66 2.38

Option List CSPF


Indoor unit Colour Unit
Wh/Wh 4.67
White
4.29 4.10

Kit name Decoration panel Fresh white


FCFC40DVM4 FCFC100DVM4 Airflow rate m3/min 23 / 18 / 13 34 / 27 / 20 36 / 29 / 21
No. Name of option Remark FCFC71DVM4
FCFC50DVM4 FCFC125DVM4 (H / M / L) cfm 812 / 635 / 459 1,200 / 953 / 706 1,271 / 1,024 / 741
FCFC85DVM4
FCFC60DVM4 FCFC140DVM4 Sound pressure level 3 (H / M/ L) dB(A) 37 / 34 / 28 38 / 34 / 29 45 / 38 / 33 46 / 40 / 33
BYCQ125EAF Dimensions Unit mm 256X840X840 298X840X840
1 Decoration panel Standard panel Fresh white
(HXWXD) Decoration panel mm 50X950X950
For usage of 3-, 4-way flow KDBH551C160
Machine Unit kg 22 24
2 Sealing material of air discharge outlet weight
For usage of 2-way flow KDBH552C160 Decoration panel kg 5.5
KDB55J160F Certified Operation range °CWB 14 to 25
3 Panel spacer
Outdoor Colour Ivory white
4
Chamber Without T-duct joint KDDP55B160 (KDDP55C160-1, KDDP55B160-2) unit Coil Type Micro channel
4 Fresh air intake kit type 1,2 With T-duct joint KDDP55B160K (KDDP55C160-1, KDDP55B160K2) 4
Hermetically sealed swing type
Compressor Type
KDDP55X160A Motor output kW 1.60 2.40
Direct installation type 3
Refrigerant charge (R32) kg 1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
(Colorimetric method 65%) KAF556D80 KAF556D160
5 High-efficiency filter unit Sound pressure level Cooling dB(A) 50 51 52 54 56
3

(Including filter chamber) (Colorimetric method 90%) KAF557D80 KAF557D160 Dimensions (HXWXD) mm 695X930X350 990X940X320
Machine weight kg 46 62
(Colorimetric method 65%) KAF552D80 KAF552D160
6 Replacement high-efficiency filter 5 Certified Operation range °CDB 21 to 46
(Colorimetric method 90%) KAF553D80 KAF553D160 Piping Liquid (Flare) mm 9.5
7 Filter chamber KDDFP55C160 connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
8 Replacement long-life filter KAF5511D160
Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
9 Ultra long-life filter unit (Including filter chamber) KAF555D160 Max. interunit piping length m 50 (Equivalent length 70)
10 Replacement ultra long-life filter 5 KAF550D160 Max. installation level difference m 30
Heat insulation Both liquid and gas piping
11 Branch duct chamber KDJP55C80 KDJP55C160
12 Insulation kit for high humidity 6 KDTP55K80A KDTP55K160A Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
Note: When installing a fresh air intake kit (chamber type), two air outlet corners are closed.
1 3
The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. 2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
2
It is recommended that the volume of outdoor air introduced through the kit is limited to 10% The chamber type is recommended when more fresh air is necessary. 3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the 4
Please order using the names of both components instead of set name.
operating sound and may also influence temperature sensing. 5
Filter chamber is required.
6
Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.

9 10
CEILING SUSPENDED TYPE

Comfortable airflow travels SPECIFICATION ( 1 Phase )


40 50 60 71 85 100

throughout the room


Indoor unit FHFC40DV14 FHFC50DV14 FHFC60DV14 FHFC71DV14 FHFC85DV14 FHFC100DV14
Model
Name Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC85DVM4 RZFC100DVM4
Power supply Outdoor unit 1 Phase, 220–240 / 220-230V, 50 / 60Hz
Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5 10.0
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2)
13,600 17,100 20,500 24,200 29,000 34,100
Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100) (17,100-38,200)
Power consumption Cooling 1 kW 1.33 1.67 2.00 2.50 2.99 3.52
FHFC40/50/60/71/85DV14 COP kW/kW 3.00 2.84
CSPF Wh/Wh 4.51 4.30 4.09
Indoor unit Colour Unit White
Airflow rate m3/min 13 / --- / 10 17 / --- / 14 24 / --- / 20 30 / --- / 25 28 / 24 / 20
(H / M / L) cfm 459 / --- / 353 600 / --- / 494 847 / --- / 706 1,059 / --- / 883 988 / 847 / 706
Sound pressure level 3 (H / M / L) dB(A) 38 / --- / 33 39 / --- / 35 42 / --- / 37 44 / --- / 39 42 / 38 / 34
Dimensions (HXWXD) Unit mm 195X960X680 195X1,160X680 195X1,400X680 195X1,590X680 235X1,590X690
Machine weight Unit kg 25 27 32 35 38
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
FHFC100/125/140DV14 unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level 3 Cooling dB(A) 48 49 50 51 52
Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
Outdoor unit mm 18.0 (Hole)
Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
Max. installation level difference m 15 30
Heat insulation Both liquid and gas piping

Option Wireless remote controller SPECIFICATION ( 3 Phase )


A signal receiver must be added to the indoor unit. 71 85 100 125 140
Accessory required for indoor unit.
Indoor unit FHFC71DV14 FHFC85DV14 FHFC100DV14 FHFC125DV14 FHFC140DV14
FHFC40-85D FHFC100-140D Model
Name
Simplified Remote Controller Cooling only Cooling only Outdoor unit RZFC71DY14 RZFC85DY14 RZFC100DY14 RZFC125DY14 RZFC140DY14
(Wired Remote Controller) BRC7EA66 BRC7GA56 Power supply Outdoor unit
Cooling Capacity 1,2 7.1 8.5
3 Phase, 380-415V, 50Hz
10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
NEW

BRC2E61 Btu/h
24,200
(10,900-27,300)
29,000
(14,300-34,100)
34,100
(17,100-38,200)
42,700
(19,500-47,800)
47,800
(21,200-52,900 )
Power consumption Cooling 1 kW 2.50 2.99 3.52 4.88 6.07
Note: Remote controller cable is not COP kW/kW 2.84 2.56 2.31
included and must be obtained CSPF Wh/Wh 4.09 3.82 3.71
locally. Signal receiver unit (Installed type) Signal receiver unit (Installed type) Colour Unit White
Indoor unit
Wireless remote controller is supplied in a Wireless remote controller is supplied in a Airflow rate m3/min 24 / --- / 20 30 / --- / 25 28 / 24 / 20 31 / 27 / 23 34 / 29 / 24
set with a signal receiver. set with a signal receiver. (H / M / L) cfm 847/ --- / 706 1,059 / --- / 883 988 / 847 / 706 1,094 / 953 / 812 1,200 / 1,024 / 847
Sound pressure level 3 (H / M / L) dB(A) 42 / --- / 37 44 / --- / 39 42 / 38/ 34 44 / 41 / 37 46 / 42 / 38
Dimensions (HXWXD) Unit mm 195X1,400X680 195X1,590X680 235X1,590X690
Option List Machine weight Unit kg 32 35 38
Kit name Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
FHFC100DV14
No. Name of option Remark FHFC40DV14 unit Coil Type Micro channel
FHFC60DV14 FHFC71DV14 FHFC85DV14 FHFC125DV14
FHFC50DV14 Compressor Type Hermetically sealed swing type
FHFC140DV14
Motor output kW 1.60 2.40
1 Replacement long-life filter Resin net KAFJ501D56 KAFJ501D80 KAFJ501D112 KAFJ501D160 KAF501B160 Refrigerant charge (R32) kg 1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
2 Fresh air intake kit -------- KDDQ50A140 Sound pressure level 3 Cooling dB(A) 50 51 52 54 56
Dimensions (HXWXD) mm 695X930X350 990X940X320
3 Drain pump kit KDU50N60VE KDU50N125VE KDU50R160
Machine weight kg 46 62
4 L-type piping kit (for upward direction) KHFP5M63 KHFP5M160 KHFP5N160 Certified Operation range °CDB 21 to 46
5 Remote controller Wireless type Cooling only BRC7EA66 BRC7GA56 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
6 Simplified remote controller Wired type 1 BRC2E61
Drain Indoor unit mm VP20 (I.D. 20XO.D. 26)
7 Central remote controller DCS302CA61 2 DCS302CA61 3 Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
8 Unified ON/OFF controller DCS301BA61 2 DCS301BA61 3 Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
9 Schedule timer DST301BA61 2 DST301BA61 3
Heat insulation Both liquid and gas piping
10 intelligent Touch Controller DCS601C51 2 DCS601C51 3
Note :
11 Adaptor for wiring BRP11B61 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
12 Wiring adaptor for electrical appendices 4 KRP4AA52 3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
13 Installation box for adaptor PCB KRP1CA93 KRP1D93A
14 Interface adaptor for SkyAir series DTA112BA51 --------
15 Remote sensor (for indoor temperature) BRCS01A-1 BRCS01A-4
16 Electrical box with earth terminal (3 blocks) KJB311AA
17 Electrical box with earth terminal (2 blocks) KJB212AA
Note: 1Wiring for wired remote controller should be obtained locally.
2
This optional accessory requires DTA112BA51.
3
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
4
Installation box for adaptor PCB (KRP1CA93, KRP1D93A) is necessary.
11 12
DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE

Perfect for narrow entranceways SPECIFICATION ( 1 Phase )

Model
Indoor unit
40
FDBF40DV14
50
FDBF50DV14
60
FDBF60DV14
71
FDBF71DV14
85
FDBF85DV14
Name Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC85DVM4
Power supply Indoor unit ----------
Outdoor unit 1 Phase, 220-240V, 50Hz
NEW Cooling Capacity 1,2
kW
4.0 5.0 6.0 7.1 8.5
Rated (Min. - Max.) (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0)

FDBF40/50/60/71/85DV14 Btu/h
13,600
(6,100-15,400)
17,100
(7,800-19,100)
20,500
(8,900-21,500)
24,200
(10,900-27,300)
29,000
(14,300-34,100)
Power consumption Cooling 1
kW 1.19 1.56 2.07 2.37 2.98
COP W/W 3.35 3.20 2.90 3.00 2.85
CSPF Wh/Wh 4.38 4.13 4.13 3.93 3.93
Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 15 / 12 / 9.5 22.5 / 20 / 17.5
cfm 530 / 424 / 335 794 / 706 / 618
External static pressure 3 Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 37 / 33 / 25 39 / 35 / 33
Air filter5 ----------
Dimensions (HXWXD) mm 245X700X800 245X1,000X800
Machine weight kg 26 36
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level Cooling
4
dB(A) 48 49 50 51
Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9
Option Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)

Accessory required for indoor unit.


Wireless remote controller Outdoor unit mm 18.0 (Hole)
A signal receiver must be added to the indoor unit. Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
Max. installation level difference m 15 30
Simplified Remote Controller
Cooling only BRC4C66 Heat insulation Both liquid and gas piping

(Wired Remote Controller)

NEW Signal receiver unit


(Separate type) SPECIFICATION ( 3 Phase )
BRC2E61 71 85
Wireless remote controller is supplied in Indoor unit FDBF71DV14 FDBF85DV14
Note: Remote controller cable is not Model
a set with a signal receiver. Name
included and must be obtained Outdoor unit RZFC71DY14 RZFC85DY14
locally.
Power supply Indoor unit ----------
Outdoor unit 3 Phase, 380-415V, 50Hz
Cooling Capacity 1,2 7.1 8.5
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0)
24,200 29,000
Mirror Pipe *New features for both FDBF and FDLF series.

Power consumption Cooling 1


Btu/h

kW
(10,900-27,300)
2.37
(14,300-34,100)
2.98
COP W/W 3.00 2.85
CSPF Wh/Wh 3.93 3.93
Enables selection of right or left piping at installation site Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 22.5 / 20 / 17.5
cfm 794 / 706 / 618
External static pressure 3 Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 39 / 35 / 33
Air filter 5 ----------
Dimensions (HXWXD) mm 245X1,000X800
Machine weight kg 36
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
Can unit Coil Type Micro channel
select! Compressor Type Hermetically sealed swing type
Motor output kW 1.60 1.60 2.40
For left side For right side
Refrigerant charge (R32) kg 1.0 (Charged for 15 m)
connection connection
Sound pressure level 4 Cooling dB(A) 50 51
Dimensions (HXWXD) mm 695X930X350
Machine weight kg 46
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 9.5
Option List connections Gas (Flare) mm 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Kit name
Outdoor unit mm 18.0 (Hole)
No. Name of option Remark FDBF40DV14 FDBF71DV14 Max. interunit piping length m 50 (Equivalent length 70)
FDBF50DV14 FDBF85DV14
FDBF60DV14 Max. installation level difference m 30
Heat insulation Both liquid and gas piping
1 Remote controller Wireless type Cooling BRC4C66
Note :
2 Simplified Remote Controller Wired type 1 BRC2E61 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3 Remote sensor (for indoor temperature) BRCS01A-1
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
Note: 1Wiring for wired remote controller should be obtained locally. 4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.

13 14
DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE

Enables high-ceiling design SPECIFICATION ( 1 Phase )


40 50 60 71 85
Indoor unit FDLF40DV14 FDLF50DV14 FDLF60DV14 FDLF71DV14 FDLF85DV14
Model
Name Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC85DVM4
Power supply Indoor unit ----------
NEW Outdoor unit 1 Phase, 220-240V, 50Hz
Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5
FDLF40/50/60/71/85DV14 Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0)
13,600 17,100 20,500 24,200 29,000
Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100)
Power consumption Cooling 1 kW 1.19 1.56 2.07 2.37 2.98
COP W/W 3.35 3.20 2.90 3.00 2.85
CSPF Wh/Wh 4.33 4.13 4.13 3.93 3.93
Indoor unit Colour ----------
Fan Airflow rate (H/M/L) m3/min 16 / 14 / 12 20 / 18 / 16.5
cfm 565 / 494 / 424 706 / 635 / 582
External static pressure 3 Pa Rated 15 (15-38)
Sound pressure level 4 (H/M/L) dB(A) 37 / 33 / 30 40 / 37 / 34
Air filter Removable / Washable / Mildew proof
Dimensions (HXWXD) mm 200X900X620 200X1,100X620
Machine weight kg 28 31
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level 4 Cooling dB(A) 48 49 50 51
Dimensions (HXWXD) mm 595X845X300 695X930X350
Option Machine weight kg 34 37 44

Accessory required for indoor unit.


Wireless remote controller Piping
Certified Operation range
Liquid (Flare)
°CDB
mm 6.4
21 to 46
9.5
A signal receiver must be added to the indoor unit. connections Gas (Flare) mm 12.7 15.9

Simplified Remote Controller


Cooling only BRC4C66 Drain Indoor unit
Outdoor unit
mm
mm
VP25 (I.D. 25XO.D. 32)
18.0 (Hole)
Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
(Wired Remote Controller) Max. installation level difference m 15 30
Heat insulation Both liquid and gas piping
NEW Signal receiver unit
(Separate type)
BRC2E61
Wireless remote controller is supplied in
Note: Remote controller cable is not
included and must be obtained
a set with a signal receiver. SPECIFICATION ( 3 Phase )
locally. 71 85
Indoor unit FDLF71DV14 FDLF85DV14
Model
Name Outdoor unit RZFC71DY14 RZFC85DY14
Power supply Indoor unit ----------
Outdoor unit 3 Phase, 380-415V, 50Hz
Easy Maintenance *New features for both FDBF and FDLF series.
Cooling Capacity 1,2
Rated (Min. - Max.) kW
7.1
(3.2-8.0)
8.5
(4.2-10.0)
24,200 29,000
Btu/h
Easier and faster cleaning Easy access to Control box Power consumption Cooling 1
kW
(10,900-27,300)
2.37
(14,300-34,100)
2.98
from bottom side COP
CSPF
W/W
Wh/Wh
3.00
3.93
2.85
3.93
Indoor unit Colour ----------
Current New Current New Fan Airflow rate (H/M/L) m3/min 20 / 18 / 16.5
cfm 706 / 635 / 582
Need to be removed The integrated fan motor Need space area inside for All wiring and maintenance
External static pressure 3 Pa Rated 15 (15-38)
by orderly can be removed and maintenance Control box can be done from bottom side Sound pressure level 4 (H/M/L) dB(A) 40 / 37 / 34
reinstalled in one time Air filter Removable / Washable / Mildew proof
Dimensions (HXWXD) mm 200X1,100X620
Machine weight kg 31
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.60 1.60 2.40
Refrigerant charge (R32) kg 1.0 (Charged for 15 m)
Sound pressure level Cooling
4
dB(A) 50 51
Dimensions (HXWXD) mm 695X930X350
Machine weight kg 46
Certified Operation range °CDB 21 to 46
Option List Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
Kit name
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
No. Name of option Remark FDLF40DV14 FDLF71DV14 Outdoor unit mm 18.0 (Hole)
FDLF50DV14 FDLF85DV14
FDLF60DV14 Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
1 Remote controller Wireless type Cooling BRC4C66
Heat insulation Both liquid and gas piping
2 Simplified Remote Controller Wired type 1 BRC2E61
Note :
3 Remote sensor (for indoor temperature) BRCS01A-1 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
Note: 1Wiring for wired remote controller should be obtained locally. 3
External static pressure is changeable in 11 stages by remote controller.
4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

15 16
DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Middle static type allows SPECIFICATION ( 1 Phase )


Indoor unit
40
FBFC40DVM4
50
FBFC50DVM4
60
FBFC60DVM4
71
FBFC71DVM4
85
FBFC85DVM4
100
FBFC100DVM4

greater flexibility
Model
Name Outdoor unit RZFC40DVM4 RZFC50DVM4 RZFC60DVM4 RZFC71DVM4 RZFC85DVM4 RZFC100DVM4
Power supply Indoor unit ----------
Outdoor unit 1 Phase, 220–240 / 220-230V, 50 / 60Hz
Cooling Capacity 1,2 4.0 5.0 6.0 7.1 8.5 10.0
Rated (Min. - Max.) kW (1.8-4.5) (2.3-5.6) (2.6-6.3) (3.2-8.0) (4.2-10.0) (5.0-11.2)
13,600 17,000 20,500 24,200 29,000 34,100
NEW Btu/h (6,100-15,400) (7,800-19,100) (8,900-21,500) (10,900-27,300) (14,300-34,100) (17,100-38,200)
Power consumption Cooling 1 kW 1.19 1.56 2.07 2.37 2.74 3.17
FBFC40/50/60/71/85/ COP W/W 3.35 3.20 2.90 3.00 3.10 3.15

100/125/140DVM4 CSPF
Indoor unit Colour
Wh/Wh 4.38 4.18 4.18
----------
3.98 3.98 3.98

Fan Airflow rate (H/M/L) m3/min 15.5 / 12 / 9 25 / 20 / 16.5 36 / 30.5 / 25


cfm 547 / 424 / 318 883 / 706 / 582 1,271 / 1,077 / 883
External static pressure 3
Pa Rated 30 (30-130) Rated 40 (40-140) Rated 50 (50-150)
Sound pressure level 4 (H/M/L) dB(A) 37 / 35 / 30 39 / 37 / 34 40 / 37.5 / 35
Air filter 5 ----------
Dimensions (HXWXD) mm 245X700X800 245X1,000X800 245X1,400X800
Machine weight kg 26 36 46
Certified Operation range °CWB 14 to 25
Outdoor Colour Ivory white
unit Coil Type Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.20 1.30 1.60
Refrigerant charge (R32) kg 0.7 (Charged for 10 m) 0.8 (Charged for 10 m) 1.0 (Charged for 15 m)
Sound pressure level 4 Cooling dB(A) 48 49 50 51 52
Dimensions (HXWXD) mm 595X845X300 695X930X350
Machine weight kg 34 37 44
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm 6.4 9.5
connections Gas (Flare) mm 12.7 15.9
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
Option Outdoor unit mm 18.0 (Hole)

Accessory required for indoor unit.


Wireless remote controller Max. interunit piping length m 30 (Equivalent length 40) 50 (Equivalent length 70)
A signal receiver must be added to the indoor unit. Max. installation level difference m 15 30
Heat insulation Both liquid and gas piping

Simplified Remote Controller


Cooling only BRC4C66
(Wired Remote Controller)

NEW Signal receiver unit SPECIFICATION ( 3 Phase )


(Separate type) 71 85 100 125 140
BRC2E61 Indoor unit FBFC71DVM4 FBFC85DVM4 FBFC100DVM4 FBFC125DVM4 FBFC140DVM4
Model
Wireless remote controller is supplied in Name Outdoor unit
Note: Remote controller cable is not RZFC71DY14 RZFC85DY14 RZFC100DY14 RZFC125DY14 RZFC140DY14
a set with a signal receiver.
included and must be obtained Power supply Indoor unit ----------
locally. Outdoor unit 3 Phase, 380-415V, 50Hz
Cooling Capacity 1,2 7.1 8.5 10.0 12.5 14.0
Rated (Min. - Max.) kW (3.2-8.0) (4.2-10.0) (5.0-11.2) (5.7-14.0) (6.2-15.5)
24,200 29,000 34,100 42,700 47,800
Btu/h (10,900-27,300) (14,300-34,100) (17,100-38,200) (19,500-47,800) (21,200-52,900)
Option List Power consumption Cooling 1
kW 2.37 2.74 3.17 5.21 6.22
Kit name COP W/W 3.00 3.10 3.15 2.40 2.25
FBFC40DVM4 FBFC100DVM4 CSPF Wh/Wh 3.98 3.98 3.98 3.71 3.60
No. Name of option Remark FBFC71DVM4
FBFC50DVM4 FBFC125DVM4 Indoor unit Colour ----------
FBFC60DVM4 FBFC85DVM4 FBFC140DVM4 Fan Airflow rate (H/M/L) m3/min 25 / 20 / 16.5 36 / 30.5 / 25
1 Long-life filter 1 KAF631C56 KAF631C80 KAF631C160 cfm 883 / 706 / 582 1,271 / 1,077 / 883
External static pressure 3 Pa Rated 40 (40-140) Rated 50 (50-150)
65% KAF632C56 KAF632C80 KAF632C160
2 High-efficiency filter 1 Sound pressure level 4 (H/M/L) dB(A) 39 / 37 / 34 40 / 37.5 / 35
90% KAF633C56 KAF633C80 KAF633C160 Air filter 5 ----------
3 Filter chamber(for rear suction)1 KDDFP63B56 KDDFP63B80 KDDFP63B160 Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800
Machine weight kg 36 46
White KTBJ25K56W KTBJ25K80W KTBJ25K160W
Certified Operation range °CWB 14 to 25
4 Service panel Fresh white KTBJ25K56F KTBJ25K80F KTBJ25K160F Ivory white
Outdoor Colour
Brown KTBJ25K56T KTBJ25K80T KTBJ25K160T unit Coil Type Micro channel
5 Air discharge adaptor Compressor Type Hermetically sealed swing type
KDAP25A56A KDAP25A71A KDAP25A140A
Motor output kW 1.60 2.40
6 Shield plate for side plate KDBD63A160 Refrigerant charge (R32) kg 1.0 (Charged for 15 m) 1.35 (Charged for 15 m)
7 Remote controller Wireless type Cooling BRC4C66 Sound pressure level Cooling
4
dB(A) 50 51 52 54 56
Dimensions (HXWXD) mm 50 695X930X350 990X940X320
8 Simplified Remote Controller Wired type 2 BRC2E61
Machine weight kg 46 62
9 Remote sensor (for indoor temperature) BRCS01A-4 Certified Operation range °CDB 21 to 46
10 Adaptor for wiring 3 BRP11B62 Piping Liquid (Flare) mm 9.5
connections Gas (Flare) mm 15.9
11 Wiring adaptor for electrical appendices(2) 3 KRP4AA51
Drain Indoor unit mm VP25 (I.D. 25XO.D. 32)
12 Mounting plate for adaptor PCB.3,4,5 KRP4A98 Outdoor unit mm 18.0 (Hole) 26.0 (Hole)
13 Central remote controller 6
DCS302CA61 Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
14 Unified ON/OFF controller 6 DCS301BA61
Heat insulation Both liquid and gas piping
15 Schedule timer 6 DST301BA61
Note :
16 intelligent Touch Controller 6 DCS601C51 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
17 Drain pump kit BDU24AMD2
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
External static pressure is changeable in 11 stages by remote controller.
Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required. 4
Up to 2 adaptors can be fixed for each mounting plate. 4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
2
Wiring for wired remote controller should be obtained locally. 5
Only one mounting plate can be installed for each indoor unit. 5
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency (gravity method) 50% or more.
3
Mounting plate is necessary for each adaptor marked . 6
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

17 18
OUTDOOR UNIT REMOTE CONTROLLER Optional accessory

Compact Outdoor Unit Simplified Remote Controller (wired)

NEW BRC2E61 ON/OFF button

Operation mode
RZFC40DVM4
RZFC85DVM4
RZFC100DVM4 Simple operation selection Temperature
RZFC50DVM4 RZFC71DY14 Using only six buttons, users have direct access to basic setting (+/-)
RZFC60DVM4 RZFC85DY14 RZFC125DY14 functions. Airflow rate
RZFC71DVM4 RZFC100DY14 RZFC140DY14 This enables them to easily set comfort to their preference. (Fan speed)

Intuitive design Airflow direction


Easy Installation and Maintenance By using pictograms, the user-friendly interface enables:

Facilitates pump down (Refrigerant recovery function) Low gas pressure detection function Overseas guests at hotels to understand functions Children and elderly users at home to operate without
A pump-down switch is provided to make it easier to collect Effective gas monitoring reduces the labor required for without having to know a foreign language. having to read difficult and hard-to-see commands.
refrigerant if the unit is to be moved or layout modified. operation, maintenance, and repairs.
*Pump-down function is available for pre-charged refrigerant amount. Compact
*Although pumping-down operation allows most of the refrigerant to be
recovered in a short period of time, some refrigerant will remain inside Measuring only 85 x 85 mm, the new remote controller is
the indoor unit and refrigerant piping. extremely compact and complements any interior design.
Using a refrigerant recovery machine, recover remaining refrigerant from
the stop valve service port until the pressure falls to 0.09 MPa. (gauge
pressure:-0.011MPa) or less. 35
Reduced size mm

Technology for energy efficiency 120 mm 120 mm


35 85 mm
mm

1 Swing compressor
High efficiency during partial load operation. 120 mm 85 mm 70 mm
3
Conventional BRC2E61 Conventional simplified
remote controller remote controller
Energy savings is realised, Swing bushing
Refrigerant gas
eliminating the friction and the 2
leakage of refrigerant gas.

Piston by incorporated 4
Wireless remote controller
blade and roller.

1 BRC7F635F BRC7GA56 The wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit of installed type is contained inside decoration panel or indoor unit.
2 Refrigerant cooling (RZFC71-140DY14) Shape of signal receiver unit differs according to the indoor unit.
Daikin’s unique refrigerant cooling system exhibits Signal receiver unit Signal receiver unit
Wireless remote controller for each indoor unit type
(Installed type) (Installed type)
high cooling capacity even during high outdoor Cooling only
temperatures. Refrigerant cooling helps protect
the printed circuit board and BRC7EA66 BRC4C66 CEILING MOUNTED CASSETTE TYPE
40-85
BRC7F635F
BRC7EA66
maintains high cooling capacity CEILING SUSPENDED TYPE
100-140 BRC7GA56
even during high outdoor DUCT CONNECTION LOW STATIC PRESSURE WIDTH COMPACT TYPE
temperatures. Signal receiver unit DUCT CONNECTION LOW STATIC PRESSURE HEIGHT COMPACT TYPE BRC4C66
Signal receiver unit
(Installed type) (Separate type) DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

3 High efficiency by micro channel heat exchanger Reduced wind resistance


The flattening of the heat exchanger tubes improves the Wired remote controller has built-in temperature-sensor
flow of air and increases heat exchange efficiency. Enables temperature sensing closer to target area for improved comfort. (When using a remote control from another room, temperature-sensor
of the indoor unit air inlet must be selected.)
Conventional tube and fin coil Micro channel coil Conventional heat Micro channel
exchanger heat exchanger
Facilitates maintenance and repair
The diameter of the
refrigerant channel
The diameter of the
refrigerant channel
All initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set
(holes where Flat, multi-hole (holes where refrigerant without having to use a stepladder to access for manual setting.
refrigerant flows) is aluminium
approx. 7 mm heat exchanger
flows) is approx.1 mm. Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).
tubes
Remote controller is equipped with error code display function. This facilitates service in the unlikely event of a malfunction.
Approx. Approx. SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying
7 mm 1 mm
Utilizing flat, multi-hole heat exchanger tubes increases interlocking operations.
the heat exchange area and realizes energy savings. Easily adaptable to large-scale, high-function, centralised remote control systems.
Flow of refrigerant Flow of refrigerant
Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.

4 Fan LCD panel shows operating status in letters, numbers, and motion.
V-cut Propeller Fan (RZFC40-100DVM4/Y14) Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Through use of a V-cut propeller fan that imitates the Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).
efficiency of the swan, a migratory bird, airflow becomes Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows
V-cut propeller fan Imitating the performance Programming time display
smooth and loss is reduced. when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
of the swan
Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

19 20
REMOTE CONTROLLER Optional accessory

System variation to control multiple indoor units


Whatever your space, give it the comfort
Control pattern Wired remote controller
LCD REMOTE CONTROLLER
Wireless remote controller it deserves
Control by 1 (Basic system)
remote controller
Non-polar, double-core Signal receiver unit installed
(max. wiring length 500 m) on indoor unit

Control by 1 wireless remote


For control from 2 controller and 1 wired remote
Control by 2 locations such as in controller (See note 2)
remote controllers room and control room, Signal receiver unit installed
Connects 2 wired remote
exits, etc. on indoor unit
controllers (See note 1)

For simultaneous
Group control control of up to 16
indoor units. Automatic address setting function Automatic address setting function
Signal receiver unit installed
on 1 indoor unit

Operation and monitoring


Control by is carried out using the (Command from outside) (Command from outside)
contact signal from the
external command operation control box in
the monitoring room. Optional wiring adaptor for Optional wiring adaptor for
*Except for FDBF and FDLF electrical appendices is necessary electrical appendices is necessary

Central remote controller (option) Central remote controller (option)

Centralised control of
Centralised remote up to 64 indoor groups
control from remote location
up to 1 km away.

Interface adapter for SkyAir series (option) is Interface adapter for SkyAir series (option) is
*Except for FDBF and FDLF required (See note 3) required (See note 3)

Heat Reclaim Heat Reclaim


Ventilator Ventilator
Link by remote
controller group control.
Can be operated simultaneously Can be operated simultaneously
or independently by remote controller by remote controller
(set by ventilation mode)
Central remote controller (option) Central remote controller (option)
Interlock control
with Heat Reclaim
Ventilator
Zone link control by Heat Reclaim Heat Reclaim
Ventilator Ventilator
centralised control.
Heat Reclaim Ventilator for indoor units within
a zone is operated by interlocking. Heat Reclaim Ventilator for indoor units within a
Can also be operated independently by zone is operated by interlocking.
*Except for FDBF and FDLF remote controller.

Note: 1BRC2E61 can connect to BRC2E61 only. 2When a wireless remote controller is used, it is not possible to use 2 wireless remote controllers. Combination of BRC2E61
(main) and wireless remote controller (sub) is available. 3FHFC40-85D requires interface adaptor for SkyAir series.

Easily adaptable to large-scale, high-function, centralised remote control system.


Central remote controller Unified on/off controller Schedule timer
DCS601C51 (Option)
DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option)

Centralised control, with setting as Centralised control of on/off by Unified control of weekly schedule With its high functionality, the full
simple as it is with a standard group or all at once for up to 256 for up to 1,024 indoor units. colour “all-in-one” graphic controller
remote controller, of up to 64 groups indoor units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
(1,024 indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.

Interface adaptor for SkyAir series Enables centralised control via connection to a The interface adaptor for SkyAir series is required for
high-speed, DIII-NET communication system, Ceiling suspended type 40-85 class.
DTA112BA51 (Option) adopted for the Daikin   system.
Necessary for interface adaptor for SkyAir series with the central remote control
units shown at above.

21 22
FUNCTIONS

Functions CEILING MOUNTED


CASSETTE TYPE
( Round Flow )
CEILING SUSPENDED TYPE
DUCT CONNECTION LOW STATIC
PRESSURE WIDTH COMPACT TYPE
DUCT CONNECTION LOW STATIC
PRESSURE HEIGHT COMPACT TYPE
DUCT CONNECTION MIDDLE STATIC
PRESSURE TYPE

overview
Cooling only Indoor unit FCFC40-140DVM4 FHFC40-85DV14 FHFC100-140DV14 FDBF40-85DV14 FDLF40-85DV14 FBFC40-140DVM4

Outdoor unit RZFC40-100DVM4 RZFC40-85DVM4 RZFC100DVM4 RZFC40-85DVM4 RZFC40-85DVM4 RZFC40-100DVM4


RZFC71-140DY14 RZFC71/85DY14 RZFC100-140DY14 RZFC71/85DY14 RZFC71/85DY14 RZFC71-140DY14

Remote Wired BRC2E61 ------- BRC2E61 ------- BRC2E61 ------- BRC2E61 ------- BRC2E61 ------- BRC2E61 -------
controller
Wireless ------- BRC7F635F ------- BRC7EA66 ------- BRC7GA56 ------- BRC4C66 ------- BRC4C66 ------- BRC4C66

1 ON / OFF timer 1

2 Auto swing 2

3 Swing pattern selection 3

4 DC fan motor 4
Comfort
5 Switchable fan speed 5 3 step 3 step 3 step 3 step 3 step 3 step
3 step 3 step 2 step 2 step 3 step 3 step

6 Auto airflow rate 6


Two selectable 7
7 temperature-sensors
8 High ceiling application 3.5m / 4.2m 3.5m 4.3 m
8

9 Anti-bacterial air filter 9 *3

Cleanliness 10 Mould-proof air filter 10

11 Silver ion anti-bacterial drain pan 11

*3 *3 *3
12 Drain pump mechanism 12

13 Pre-charged for up to 10 / 15 m *1 13

14 Long-life filter 14 *3

Work &
Servicing 15 Filter sign 15

16 Low gas pressure detection *1 16

17 Emergency operation *4 *4 *4 17 *4 *4 *4

18 Self-diagnosis function 18

19 Auto-restart 19

20 Control by 2 remote controllers *5 *5 *5 20 *5 *5 *5

21 Group control by 1 remote controller 21

22 External signal forced OFF and 22


ON/OFF operation
Control
23 External command control *2 23

24 Central remote control *3 24


Interlock control with
25 Heat Reclaim Ventilator 25

26 DIII-NET communication standard *3 26

27 High-efficiency filter 27

Options 28 Ultra long-life filter 28

29 Fresh air intake kit 29

Note:
*1: For outdoor units. *2: Wiring adaptor for electrical appendices (and installation box) is necessary. *3: Option is requied. *4: For outdoor unit RZFC-DY14 only. *5: It is not possible to use 2 wireless remote controllers. Combination of BRC2E61 (main) and wireless remote controller (sub) is available.

23 24
Product Lineup
Series 25 35 50 60 71 100 125 140
CEILING MOUNTED
CASSETTE TYPE
Round Flow

Indoor unit FCQ50CKAVE4 FCQ60KAVE4 FCQ71KAVE4 FCQ100KAVE4 FCQ125KAVE4 FCQ140KAVE4


Outdoor unit RZR50MVM4 RZR50MVM4 RZR50MVM4 RZR50MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14

COMPACT MULTI FLOW


CEILING MOUNTED
CASSETTE TYPE

Indoor unit FFQ25BV1B4 FFQ35BV1B4 FFQ50BV1B4 FFQ60BV1B4


Outdoor unit RKS25AVMG4 RKS35AVMG4 RKS50AVMG4 RKS60AVMG4

CEILING SUSPENDED TYPE

Indoor unit FHQ50DAVM4 FHQ60DAVM4 FHQ71DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4


Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14

WALL MOUNTED TYPE

Indoor unit FAQ100CVEA4


Outdoor unit RZR100MYM4

DUCT CONNECTION
MIDDLE STATIC
PRESSURE TYPE

Indoor unit FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ125EVE4 FBQ125EVE4 FBQ140EVE4


Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14

FLOOR STANDING TYPE

Indoor unit FVQ50CVEB4 FVQ60CVEB4 FVQ71CVEB4 FVQ100CVEB4 FVQ125CVEB4 FVQ140CVEB4


Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14

OUTDOOR UNIT

Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MYM4 RZR125MYM4 RZR125LUY14 RZR140MYM4 RZR140LUY14

OUTDOOR UNIT

Outdoor unit RKS25AVMG4 RKS35AVMG4 RKS50AVMG4 RKS60AVMG4

25 26
CEILING MOUNTED CASSETTE TYPE Round Flow

SPECIFICATION (3 Phase)

Cassette air conditioner with 360° Model


Name
Indoor unit
Outdoor unit
125
FCQ125KAVE4
140
FCQ140KAVE4
125
FCQ60KAVE4x2
140
FCQ71KAVE4x2
125
FCQ125KAVE4
140
FCQ140KAVE4
RZR125LVVM4 RZR140LVVM4 RZR125LVVM4 RZR140LVVM4 RZR125LUY14 RZR140LUY14 RZR125LUY14 RZR140LUY14
125
FCQ60KAVE4x2
140
FCQ71KAVE4x2

uniform airflow sets the standard


Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 12.5 14.0 12.5 14.0 12.5 14.0 12.5 14.0
kW
Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)

Btu/h 42,700 47,800 42,700 47,800 42,700 47,800 42,700 47,800


(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
Power consumption Cooling1 kW 3.68 4.91 3.68 4.91 3.68 4.91 3.68 4.91

FCQ50/6071/100/125/140KA COP W/W 3.40 2.85 3.40 2.85 3.40 2.85 3.40 2.85
Indoor Airflow rate (H/M/L) m3/min 33/28/22.5 21/17.5/13.5 33/28/22.5 21/17.5/13.5
unit cfm 1,165/988/794 741/618/477 1,165/988/794 741/618/477
Sound pressure level 3 (H/M/L) dB(A) 44/39/34 44/40/36 35/31.5/28 44/39/34 44/40/36 35/31.5/28
Dimensions Unit mm 298X840X840 256X840X840 298X840X840 256X840X840
(HXWXD) Decoration panel mm 50X950X950
Machine Unit kg 24 21 24 21
weight Decoration panel kg 5.5
Certified Operation range °CWB 14 to 25
Outdoor Coil Type Cross fin coil
unit Compressor Type Hermetically sealed scroll type
Motor output kW 2.4 3.1 2.4 3.1 2.4 3.1 2.4 3.1
Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7 (Charged for 30 m)
Sound pressure Cooling dB(A) 50
level3 Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Dimensions (HXWXD) mm 1,170X900X320
Machine weight kg 97
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP25 (I.DØ25XO.D Ø32)
Outdoor unit mm Ø26.0 (Hole)
Accessory required for indoor unit. Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Navigation Remote Controller Wired LCD Remote Controller Wireless LCD remote controller Note :
(Wired Remote Controller) A signal receiver must be added to the indoor unit. 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
BRC7F635F
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

BRC1E63 BRC1C61 Signal receiver unit


Note: Remote controller cable is not Note: Remote controller cable is not (Installed type)
included and must be included and must be Wireless remote
obtained locally. obtained locally.
Option List
controller is supplied
in a set with a signal
receiver.
Kit name
Name of option Remark
FCQ50KAVE4 FCQ60KAVE4 FCQ71KAVE4 FCQ100KAVE4 FCQ125KAVE4 FCQ140KAVE4
Decoration panel BYCP125K-W1
FEATURES Sealing material of air discharge outlet KDBH55K160F
Panel spacer KDBP55H160FA
36O° AIRFLOW SILVER ION ANTI-BACTERIAL DRAIN PAN SUITABLE FOR HIGH CEILINGS Fresh air Chamber Without T-duct joint KDDP55B160
intake kit1 type With T-duct joint KDDP55B160K
GENTLE AIR MOVEMENT WITH ROUND FLOW ANTI-MOULD & ANTI-BACTERIAL TREATMENT QUICK & EASY TO INSTALL Direct installation type KDDP55X160
FILTER High-efficiency filter unit (Colorimetric method 65%) KAFP556B80 KAFP556B160
(including filter chamber) (Colorimetric method 90%) KAFP557B80 KAFP557B160
Replacement (Colorimetric method 65%) KAFP552B80 KAFP552B160
SPECIFICATION (1 Phase) high-efficiency filter (Colorimetric method 90%) KAFP553B80 KAFP553B160
50 60 71 100 125 140 100 125 140 Filter chamber KDDFP55B160
Replacement long-life filter KAFP551K160
Model Indoor unit FCQ50KAVE4 FCQ60KAVE4 FCQ71KAVE4 FCQ100KAVE4 FCQ125KAVE4 FCQ140KAVE4 FCQ100KAVE4 FCQ125KAVE4 FCQ140KAVE4
Ultra long-life filter unit (including filter chamber) KAFP55B160
Name Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MVM4 RZR125MVM4 RZR140MVM4 RZR100MYM4 RZR125MYM4 RZR140MYM4 Replacement ultra long-life filter KAFP55H160H
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Branch duct chamber KDJP55B80 KDJP55B160
5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0 Chamber connection kit2 KKSJ55KA160
Cooling capacity1,2
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) Insulation kit for high humidity KDTP55K80 KDTP55K160
Rated (Min. - Max.)
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 Remote controller Wireless type Cooling only BRC7F635F
Btu/h (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) Wired type3 BRC1C61
Power consumption Cooling1 kW 1.24 1.58 1.99 2.78 4.31 5.62 2.78 4.31 5.62 Navigation Remote Controller Wired type3 BRC1E62
COP W/W 4.03 3.80 3.57 3.60 2.90 2.49 3.60 2.90 2.49 Central remote controller4 DCS302CA61
Indoor Airflow rate (H/M/L) m3/min 21/17.5/13.5 32/26/20 33/28/22.5 32/26/20 33/28/22.5 Unified ON/OFF controller4 DCS301BA61
unit cfm 741/618/477 1,130/918/706 1,165/988/794 1,130/918/706 1,165/988/794 Schedule timer4 DST301BA61
Sound pressure level 3 (H/M/L) dB(A) 35/31.5/28 43/37.5/32 44/39/34 44/40/36 43/37.5/32 44/39/34 44/40/36 intelligent Touch Controller4 DCS601C51
Dimensions Unit mm 256X840X840 298X840X840 Adaptor for wiring5 KRP1C63
(HXWXD) Decoration panel mm 50X950X950 Wiring adaptor for electrical appendices(2)5 KRP4AA53
Machine Unit kg 21 24 Installation box for adaptor PCB KRP1H98
weight Decoration panel kg 5.5 Remote sensor (for indoor temperature) KRCS01-4B
Certified Operation range °CWB 14 to 25 Note: 1Refer to page 20 for the details.
2
Coil Type Cross fin coil Micro channel Required for installing high-efficiency filter unit and ultra long-life filter unit.
Outdoor 3
Wiring for wired remote controller to be procured locally.
unit Compressor Type Hermetically sealed swing type 4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Motor output kW 1.12 1.35 1.76 2.03 1.92 5
Installation box for adaptor PCB (KRP1H98) is necessary.
Refrigerant charge (R-410A) kg 1.6(Charged for 30 m) 1.9(Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
level3 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight kg 43 65 73
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP25 (I.D Ø25XO.D Ø32)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30

27 28
CEILING MOUNTED
COMPACT MULTI FLOW CASSETTE TYPE

COMPACT MULTI FLOW CEILING MOUNTED CASSETTE TYPE

Quiet decor-blending form and easy Model


Name
Indoor unit
Outdoor unit
25
FFQ25BV1B4

RKS25AVMG4
35
FFQ35BV1B4

RKS35AVMG4
50
FFQ50BV1B4

RKS50AVMG4
60
FFQ60BV1B4

RKS60AVMG4

installation in new or old building


Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz
Cooling capacity1 2.5 3.4 4.7 5.8
Rated (Min. - Max.)
kW (1.2-3.0) (1.2-3.7) (1.7-5.6) (1.7-6.0)
8,500 11,600 16,000 19,800
Btu/h (4,100-10,250) (4,100-12,600) (5,800-19,100) (5,800-20,500)
Power consumption Cooling1 kW 0.73 1.10 1.62 2.07
COP W/W 3.42 3.09 2.90 2.80
FFQ25/35/50/60B Indoor
Airflow rate (H/L) m3/min 9/6.5 10/6.5 12/8 15/10
cfm 317/229 353/229 423/282 529/353
unit
Sound pressure level2 (H/L) dB(A) 29.5/24.5 32/25 36/27 41/32
Dimensions Unit mm 286X575X575
(HXWXD) Decoration panel mm 55X700X700
Machine weight Unit kg 17.5
Decoration panel kg 2.7
Certified operation range °CWB 14 to 23
Coil Type Cross fin coil
Outdoor
unit Compressor Type Hermetically sealed swing type
Motor output kW 0.6 1.1
Refrigerant charge (R-410A) 1.0 1.5
kg
(Charged for 10 m) (Charged for 10 m)
Sound pressure level2 dB(A) 46 47 49
Dimensions (HXWXD) mm 550X765X285 735X825X300
Machine weight kg 34 47
Certified operation range °CDB 10 to 46
Piping Liquid (Flare) mm Ø6.4
connections Gas (Flare) mm o/ 9.5 o/ 12.7
Drain Indoor unit mm VP20 (I.D Ø20XO.D Ø26)
Outdoor unit mm Ø18.0 (Hole)
Max. interunit piping length m 20 30
Accessory required for indoor unit.
Max. installation level difference m 15 20

Navigation Remote Controller Note :


1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
(Wired Remote Controller) 2
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

BRC1E63 Option List


Note: Remote controller cable is not Kit name
included and must be obtained Name of option Remark
locally.
FFQ25BV1B4 FFQ35BV1B4 FFQ50BV1B4 FFQ60BV1B4
Decoration panel BYFQ60B3W1
Remote controller Wireless type Cooling only BRC7E531W
Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
Adaptor for wiring2 KRP1BA57
Wiring adaptor for electrical appendices2 KRP4AA53
Wired LCD Remote Controller Remote sensor (for indoor temperature) KRCS01-1B
Installation box for adaptor PCB KRP1BA101
Central remote controller3 DCS302CA61
Unified ON/OFF controller3 DCS301BA61
Schedule timer3 DST301BA61
BRC1C61 intelligent Touch Controller3 DCS601C51
Note: Remote controller cable is not Interface adaptor for SkyAir series DTA112BA51
included and must be obtained Replacement long-life filter KAFQ441BA60
locally. Fresh air intake kit Direct installation type KDDQ44XA60
Sealing material of air discharge outlet KDBH44BA60
Panel spacer KDBQ44BA60A
Note: 1Wiring for wired remote controller to be procured locally.
2
Installation box for adaptor PCB (KRP1BA101) is necessary.
3
This optional accessory requires DTA112BA51.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7E531W
Signal receiver unit
(Installed type)
Wireless remote
controller is supplied
in a set with a signal
receiver.

FEATURES
SIZED TO FIT INSIDE 600mm WIDE CEILING GRIDS QUIET, SMALL-DIAMETER FAN CONSISTENT COMFORT THROUGHOUT

MULTI-FLOW SYSTEM AIR DIRECTION CAN BE SELECTED TWO SELECTABLE TEMPERATURE-SENSORS


ACCORDING TO INSTALLATION

29 30
CEILING SUSPENDED TYPE

Comfortable airflow travels SPECIFICATION (3 Phase)


Model Indoor unit
125 140 125 140 125 140
FHQ125DAVM4 FHQ140DAVM4 FHQ60DAVM4x2 FHQ71DAVM4x2 FHQ125DAVM4 FHQ140DAVM4 FHQ60DAVM4x2 FHQ71DAVM4x2
125 140

throughout the room


Name Outdoor unit RZR125LVVM4 RZR140LVVM4 RZR125LVVM4 RZR140LVVM4 RZR125LUY14 RZR140LUY14 RZR125LUY14 RZR140LUY14
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 12.5 13.3 12.5 13.3 12.5 13.3 12.5 13.3
kW
Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
42,700 45,000 42,700 45,000 42,700 45,000 42,700 45,000
Btu/h
(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)

FHQ50/60/71/100/125/140DA Power consumption


COP
Cooling1 kW
W/W
2.83
4.00
3.12
2.52
4.68
2.84
2.83
4.00
3.12
2.52
4.68
2.84
2.83
4.00
3.12
2.52
4.68
2.84
2.83
4.00
3.12
2.52
4.68
2.84
Airflow rate (H/M/L) m3/min 31/27/23 34/29/24 15/12/10 20.5/17/14 31/27/23 34/29/24 15/12/10 20.5/17/14
Indoor
unit cfm 1,094/953/812 1,200/1,024/847 530/424/353 724/600/494 1,094/953/812 1,200/1,024/847 530/424/353 724/600/494
Sound pressure level3 (H/M/L) dB(A) 44/41/37 46/42/38 37/35/32 38/36/34 44/41/37 46/42/38 37/35/32 38/36/34
Dimensions (HXWXD) mm 235X1590X690 235X960X690 235X1,270X690 235X1590X690 235X960X690 235X1,270X690
Machine weight kg 38 25 32 38 25 32
Certified operation range °CWB 14 to 25
Coil Type Cross fin coil
Outdoor
unit Compressor Type Hermetically sealed scroll type
Motor output kW 2.4 3.1 2.4 3.1 2.4
2.6 3.1
2.9 2.4 3.1
2.9
Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7(Charged for 30 m)
Sound pressure Cooling dB(A) 50
level3 Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Dimensions (HXWXD) mm 1,170X900X320
Machine weight kg 97
Certified operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP20 (I.DØ20XO.D Ø26)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Accessory required for indoor unit.
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
Navigation Remote Controller Wired LCD Remote Controller Wireless LCD remote controller 2
3
Capacities are net, including a deduction for cooling for indoor fan motor heat.
(Wired Remote Controller) A signal receiver must be added to the indoor unit. The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

BRC7GA56
BRC1E63 BRC1C61
Note: Remote controller cable is not Note: Remote controller cable is not
included and must be included and must be
obtained locally. obtained locally. Signal receiver unit (Installed type)
Wireless remote controller is supplied
Option List
in a set with a signal receiver. Kit name
Name of option Remark
FHQ50DAVM4 FHQ60DAVM4 FHQ71DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4
Replacement long-life filter Resin net KAFP501A56 KAFP501A80 KAFP501A160
FEATURES Fresh air intake kit KDDQ50A140
Drain pump kit KDU50P140VE
SOPHISCATED DESIGN AUTO SWING & LOUVERS SUITABLE FOR HIGH CEILINGS L-type piping kit (for upward direction) KHFP5N160
Remote controller Wireless type Cooling only BRC7GA56
Wired type1 BRC1C61
FLEXIBLE INSTALLATION NON FLOCKING FLAP QUIET OPERATION Navigation Remote Controller Wired type1 BRC1E62
Central remote controller DCS302CA61
Unified ON/OFF controller DCS301BA61
Schedule timer DST301BA61
SPECIFICATION (1 Phase) intelligent Touch Controller2 DCS601C51
50 60 71 100 125 140 100 125 140 Wiring adaptor for electrical appendices KRP1BA54
FHQ50DAVM4 FHQ60DAVM4 FHQ71DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4 FHQ100DAVM4 FHQ125DAVM4 FHQ140DAVM4 Wiring adaptor for electrical appendices3 KRP4AA52
Model Indoor unit
Installation box for adaptor PCB KRP1D93A
Name Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MVM4 RZR125MVM4 RZR140MVM4 RZR100MYM4 RZR125MYM4 RZR140MYM4 Adaptor box mounting plate KKSAP50A56 ----------
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz Remote sensor (for indoor temperature) KRCS01-4B
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0 Electrical box with earth terminal (3 blocks) KJB311AA
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0)
Rated (Min. - Max.) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) Electrical box with earth terminal (2 blocks) KJB212AA
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 Note: 1Wiring for wired remote controller to be procured locally.
Btu/h (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800)
(21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) 2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Cooling1 kW 1.24 1.58 2.37 3.03 4.42 Installation box for adaptor PCB(KRP1D93A) is necessary.
Power consumption 5.55 3.03 4.42 5.55
COP W/W 4.03 3.80 3.00 3.30 2.83 2.52 3.30 2.83 2.52
Airflow rate (H/M/L) m3/min 15/12/10 20.5/17/14 28/24/20 31/27/23 34/29/24 28/24/20 31/27/23 34/29/24
Indoor
cfm 530/424/353 724/600/494 988/847/706 1,094/953/812 1,200/1,024/847 988/847/706 1,094/953/812 1,200/1,024/847
unit 3
Sound pressure level (H/M/L) dB(A) 37/35/32 38/36/34 42/38/34 44/41/37 46/42/38 42/38/34 44/41/37 46/42/38
Dimensions (HXWXD) mm 235X960X690 235X1,270X690 235X1,590X690
Machine weight kg 25 32 38
Certified operation range °CWB 14 to 25
Coil Type Cross fin coil Micro channel
Outdoor
unit Compressor Type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9(Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
level3 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight kg 43 65 73
Certified operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP20 (I.D Ø20XO.D Ø26)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30

31 32
WALL MOUNTED TYPE

Compact design SPECIFICATION ( 1 Phase, 3 Phase )


Model Indoor unit
100
FAQ100CVEA4
100
FAQ100CVEA4

and easy installation


Name
Outdoor unit RZR100MVM4 RZR100MYM4
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 10.0
kW (5.0-11.2)
Rated (Min. - Max.)
34,100
Btu/h (17,100-38,200)

FAQ100C Power consumption


COP
Cooling1 kW
W/W
3.37
2.97
Airflow rate (H/M/L) m3/min 26/23/19
Indoor
cfm 918/812/671
unit
Sound pressure level3 (H/M/L) dB(A) 49/45/41
Dimensions (HXWXD) mm 340X1,200X240
Machine weight kg 17
Certified Operation range °CWB 14 to 25
Coil Type Micro channel
Outdoor
Compressor Type Hermetically sealed swing type
unit
Motor output kW 2.03 1.92
Refrigerant charge (R-410A) kg 1.9 (Charged for 30 m)
Sound pressure Cooling dB(A) 49
level 3 Night quiet mode dB(A) 45
Dimensions (HXWXD) mm 990X940X320
Machine weight kg 65 73
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP13 (O.DØ18 X I.D Ø13)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70m)
Accessory required for indoor unit. Max. installation level difference m 30
Note :
Navigation Remote Controller
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
(Wired Remote Controller) 3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

BRC1E63
Note: Remote controller cable is not
included and must be obtained
locally.
Option List
Kit name
Name of option Remark
FAQ100CVEA4
Drain-up kit K-KDU572EVE
Remote controller Wireless type Cooling only BRC7EB519
Wired type1 BRC1C61
Wired LCD Remote Controller Navigation Remote Controller
Remote sensor (for Indoor temperature)
Wired type1 BRC1E62
KRCS01-4B
Central remote controller2 DCS302CA61
Unified ON/OFF controller2 DCS301BA61
Schedule timer2 DST301BA61
BRC1C61 intelligent Touch Controller2 DCS601C51
Note: Remote controller cable is not
Wiring adaptor for electrical appendices3 KRP4AA51
included and must be obtained Installation box for adaptor PCB KRP4AA93
locally. Electrical box with earth terminal (3 blocks) KJB311AA
Electrical box with earth terminal (2 blocks) KJB212AA
Noise filter ( For electromagnetic interface use only) KEK26-1A
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA93) is necessary.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7EB519

Signal receiver unit (Installed type)


Wireless remote controller is supplied in
a set with a signal receiver.

FEATURES
COMPACT & SOPHISCATED DESIGN AUTO SWING & WIDE-ANGEL LOUVERS COMFORT EVEN ON THE FAR SIDE OF THE ROOM

6-DIRECTION REFRIGERANT PIPING FLEXIBILITY INTERLOCK CONTROL EASY CLEANING

33 34
DUCT CONNECTION MIDDLE and HIGH STATIC PRESSURE TYPE

Thinner design allows greater SPECIFICATION (1 Phase)


Model Indoor unit
50 60 71 100 125 140
FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4
100 125 140

installation flexibility
Name Outdoor unit RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MVM4 RZR125MVM4 RZR140MVM4 RZR100MYM4 RZR125MYM4 RZR140MYM4
Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz
Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0
kW (2.3-5.6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4)
Rated (Min. - Max.)
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800
Btu/h
FBQ50/60/71/100/125/140E Power consumption Cooling1 kW
(7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600)
1.39 1.69 2.22 2.82 4.58 5.85 2.82 4.58 5.85
COP W/W 3.60 3.56 3.20 3.55 2.73 2.39 3.55 2.73 2.39
CSPF Wh/Wh 5.40 5.20 5.04 4.73 4.61 4.38 4.73 4.61 4.38
Indoor Colour ----------
unit Fan Airflow rate (H/M/L) m3/min 18/15/12.5 23/19.5/16 32/27/22.5 36/30.5/25 32/27/22.5 36/30.5/25
cfm 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 1,130/953/794 1,271/1,077/883
External static pressure3 Pa Rated 50 (50-150)
Sound pressure level4 (H/M/L) dB(A) 35/33/31 38/35/33 38/35.5/33 40/37.5/35 38/35.5/33 40/37.5/35
Air filter5 ----------
Dimensions (HXWXD) mm 245X1,000X800 245X1,400X800
Machine weight kg 37 47
Certified Operation range °CWB 14 to 25
Colour Ivory white
Outdoor
unit Coil Type Cross fin coil Micro channel
Compressor Type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9(Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
level4 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight kg 43 65 73
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP25 (I.DØ25XO.D Ø32)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30
Accessory required for indoor unit. Both liquid and gas piping
Heat insulation

Navigation Remote Controller Wired LCD Remote Controller Wireless LCD remote controller
(Wired Remote Controller) A signal receiver must be added to the indoor unit.

BRC4C66 SPECIFICATION (3 Phase)


BRC1E63 BRC1C61 125 140 125 140 125 140 125 140
Signal receiver unit
Note: Remote controller cable is not Note: Remote controller cable is not (Installed type) Model Indoor unit FBQ125EVE4 FBQ140EVE4 FBQ60EVE4x2 FBQ71EVE4x2 FBQ125EVE4 FBQ140EVE4 FBQ60EVE4x2 FBQ71EVE4x2
included and must be included and must be Wireless remote Name Outdoor unit
obtained locally. obtained locally. controller is supplied RZR125LVVM4 RZR140LVVM4 RZR125LVVM4 RZR140LVVM4 RZR125LUY14 RZR140LUY14 RZR125LUY14 RZR140LUY14
in a set with a signal
receiver. Power supply Indoor unit 1 Phase, 220–240 V, 50 Hz
Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 12.5 14.0 12.5 14.0 12.5 14.0 12.5 14.0
kW (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
Rated (Min. - Max.)
FEATURES Btu/h
42,700 47,800 42,700 47,800 42,700 47,800 42,700 47,800
(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
DESIGN & INSTALLATION FLEXIBILITY SILVER ION ANTI-BACTERIAL DRAIN PAN SWITCHABLE FAN SPEED Power consumption Cooling1 kW 3.73 4.71 3.73 4.71 3.73 4.71 3.73 4.71
COP W/W 3.35 2.97 3.35 2.97 3.35 2.97 3.35 2.97
Indoor Colour ----------
ADJUSTABLE EXTERNAL STATIC PRESSURE INTERLOCK CONTROL EASY MAINTENANCE Fan Airflow rate (H/M/L) m3/min 36/30.5/25 18/15/12.5
23/19.5/16 36/30.5/25 18/15/12.5 23/19.5/16
unit
cfm 1,271/1,077/883 635/530/441
812/688/565 1,271/1,077/883 635/530/441 812/688/565
External static pressure3 Pa Rated 50 (50-150)
Sound pressure level4 (H/M/L) dB(A) 40/37.5/35 35/33/31 38/35/33 40/37.5/35 35/33/31 38/35/33
Option List Air filter5 ----------
Kit name Dimensions (HXWXD) mm 245X1,400X800 245X1,000X800 245X1,400X800 245X1,000X800
Name of option Remark kg
FBQ50EVE4 FBQ60EVE4 FBQ71EVE4 FBQ100EVE4 FBQ125EVE4 FBQ140EVE4 Machine weight 47 37 47 37
High-efficiency filter1 65% KAFP632B80 KAFP632B160 Certified Operation range °CWB 14 to 25
90% KAFP633B80 KAFP633B160 Colour Ivory white
Outdoor
Filter chamber(for rear suction)1 KDDFP63B80 KDDFP63B160 unit Coil Type Cross fin coil
Long-life filter1 KAFP631B80 KAFP631B160 Compressor Type Hermetically sealed scroll type
Service panel White KTBJ25K80W KTBJ25K160W Motor output kW 2.4 2.9 2.4 2.9 2.4 2.9 2.4 2.9
Fresh white KTBJ25K80F KTBJ25K160F Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7(Charged for 30 m)
Brown KTBJ25K80T KTBJ25K160T Sound pressure Cooling dB(A) 50
Air discharge adaptor KDAP25A71A KDAP25A140A level4 Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Shield plate for side plate KDBD63A160 Dimensions (HXWXD) mm 1,170X900X320
Remote controller Wireless type Cooling only BRC4C66 Machine weight kg 97
Wired type2 BRC1C61 Certified Operation range °CDB 21 to 46
Navigation Remote Controller Wired type2 BRC1E62 Piping Liquid (Flare) mm Ø9.5
Adaptor for wiring KRP1C64 connections Gas (Flare) mm Ø15.9
Wiring adaptor for electrical appendices(2) KRP4AA51 Drain Indoor unit mm VP25 (I.DØ25XO.D Ø32)
Remote sensor KRCS01-4B Outdoor unit mm Ø26.0 (Hole)
Mounting plate for adaptor PCB.3,4,5 KRP4A98 Max. interunit piping length m 50 (Equivalent length 70)
Central remote controller6 DCS302CA61 Max. installation level difference m 30
Unified ON/OFF controller6 DCS301BA61 Heat insulation Both liquid and gas piping
Schedule timer6 DST301BA61 Note :
intelligent Touch Controller6 DCS601C51 1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required. 4
Up to 2 adaptors can be fixed for each mounting plate. 3
External static pressure is changeable in 11 stages by remote controller.
2 5
Wiring for wired remote controller to be procured locally. Only one mounting plate can be installed for each indoor unit. 4
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
3 6 5
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.

35 36
FLOOR STANDING TYPE
SPECIFICATION (1 Phase)

New airflow control Model


Name
Indoor unit
Outdoor unit
50 60 71 100 125 140
FVQ50CVE4 FVQ60CVE4 FVQ71CVEB4 FVQ100CVEB4 FVQ125CVEB4 FVQ140CVEB4 FVQ100CVEB4 FVQ125CVEB4 FVQ140CVEB4

RZR50MVM4 RZR60MVM4 RZR71MVM4 RZR100MVM4 RZR125MVM4 RZR140MVM4 RZR100MYM4 RZR125MYM4 RZR140MYM4


100 125 140

for more comfort


Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 5.0 6.0 7.1 10.0 12.5 14.0 10.0 12.5 14.0
kW
Rated (Min. - Max.) (2.3-5,6) (2.6-6.3) (3.2-8.0) (5.0-11.2) (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4)
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800
Btu/h
(7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600)
Power consumption Cooling1 kW 1.27 1.84 2.58 3.28 4.62 5.89 3.28 4.62 5.89
COP W/W 3.94 3.26 2.75 3.05 2.71 2.38 3.05 2.71 2.38
Indoor Fan Airflow rate (H/M/L) m3/min 18/16/14 28/25/22 28/26/24 30/28/26 28/25/22 28/26/24 30/28/26
unit cfm 635/565/494 988/883/777 988/918/847 1,059/988/918 988/883/777 988/918/847 1,059/988/918
Sound pressure level3 (H/M/L) dB(A) 43/41/38 50/47/44 51/48/46 53/51/48 50/47/44 51/48/46 53/51/48
FVQ50/60/71/100/125/140C Dimensions (HXWXD) mm
kg
1,850X600X270 1,850X600X350
Machine weight 39 47
Certified Operation range °CWB 14 to 25
Outdoor Coil Type Cross fin coil Micro channel
unit Compressor Type Hermetically sealed swing type
Motor output kW 1.12 1.35 1.76 2.03 1.92
Refrigerant charge (R-410A) kg 1.6 (Charged for 30 m) 1.9 (Charged for 30 m)
Sound pressure Cooling dB(A) 48 49 52 54 49 52 54
level3 Night quiet mode dB(A) 44 45
Dimensions (HXWXD) mm 595X845X300 990X940X320
Machine weight kg 43 65 73
Certified Operation range °CDB 21 to 46
Piping Liquid (Flare) mm Ø9.5
connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP20 (I.DØ20XO.D Ø26)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30

BRC1E63
can be SPECIFICATION (3 Phase)
incorporated 125 140 125 140 125 140 125 140
into the Model Indoor unit FVQ125CVEB4 FVQ140CVEB4 FVQ60CVE4x2 FVQ71CVEB4x2 FVQ125CVEB4 FVQ140CVEB4 FVQ60CVE4x2 FVQ71CVEB4x2
indoor unit. Name Outdoor unit RZR125LVVM4 RZR140LVVM4 RZR125LVVM4 RZR140LVVM4 RZR125LUY14 RZR140LUY14 RZR125LUY14 RZR140LUY14
Power supply Outdoor unit 1 Phase, 220–240 V, 50 Hz 3 Phase, 380–415 V, 50 Hz
Cooling capacity1,2 12.5 13.5 12.5 13.5 12.5 13.5 12.5 13.5
kW
Rated (Min. - Max.) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4) (5.7-14.0) (6.2-15.4)
42,700 46,100 42,700 46,100 42,700 46,100 42,700 46,100
Btu/h
(19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600) (19,500-47,800) (21,200-52,600)
Power consumption Cooling1 kW 4.39 5.40 4.39 5.40 4.39 5.40 4.39 5.40
COP W/W 2.85 2.50 2.85 2.50 2.85 2.50 2.85 2.50
Indoor Fan Airflow rate (H/M/L) m3/min 28/26/24 30/28/26 18/16/14 28/26/24 30/28/26 18/16/14
unit cfm 988/918/847 1,059/988/918 635/565/494 988/918/847 1,059/988/918 635/565/494
3
Sound pressure level (H/M/L) dB(A) 51/48/46 53/51/48 43/41/38 51/48/46 53/51/48 43/41/38
Dimensions (HXWXD) mm 1,850X600X350 1,850X600X270 1,850X600X350 1,850X600X270
Machine weight kg 47 39 47 39
Certified Operation range °CWB 14 to 25
Accessory required for indoor unit. Coil Type Cross fin coil
Outdoor
unit Compressor Type Hermetically sealed scroll type
Motor output kW 2.4 3.1 2.4 3.1 2.8 3.4 2.8 3.4
Navigation Remote Controller Refrigerant charge (R-410A) kg 3.15 (Charged for 30 m) 3.7 (Charged for 30 m)
(Wired Remote Controller) Sound pressure Cooling dB(A) 50
level3
Night quiet mode dB(A) 45 46 45 46 45 46 45 46
Dimensions (HXWXD) mm 1,170X900X320
BRC1E63 Machine weight kg 97
Note: Remote controller cable is not Certified Operation range °CDB 21 to 46
included and must be procured Piping Liquid (Flare) mm Ø9.5
locally. connections Gas (Flare) mm Ø15.9
Drain Indoor unit mm VP20 (I.DØ20XO.D Ø26)
Outdoor unit mm Ø26.0 (Hole)
Max. interunit piping length m 50 (Equivalent length 70)
Max. installation level difference m 30

Wired LCD remote controller Note :


1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
2
Capacities are net, including a deduction for cooling for indoor fan motor heat.
3
The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.
BRC1C61
Note: Remote controller cable is not Option List
included and must be procured
locally. Kit name
Name of option Remark
FVQ50CVE4 FVQ60CVE4 FVQ71CVEB4 FVQ100CVEB4 FVQ125CVEB4 FVQ140CVEB4
Replacement long-life filter KAFJ95L160
Remote controller Wired type1 BRC1C61
Navigation Remote Controller Wired type1 BRC1E62
Central remote controller2 DCS302CA61
Unified ON/OFF controller2 DCS301BA61
FEATURES Schedule timer2 DST301BA61
intelligent Touch Controller2 DCS601C51
NEW COMFORTABLE AIRFLOW CONTROL SWITCHABLE FAN SPEED QUIET OPERATION Adaptor for wiring3 KRP1BA57
Wiring adaptor for electrical appendices KRP4AA52
LONG-LIFE FILTER SAFETY LOCK FUNCTION OF SUCTION GRILLE QUICK & EASY TO INSTALL & MAINTENANCE Installation box for adaptor PCB KRP4AA95
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA95) is necessary.

37 38