QB2000N

Fixed Module Sensor Gas Detector

Operation
Manual

Henan Chicheng Electric Co.,Ltd


ISO9001 & Quality Assured Company
Safety information:
⇒ Any operation inside the detector must be carried by
professional personnel. Before operating and repairing. Please
read carefully and understand clearly the operation manual.
⇒ It is suggested calibrate the sensor once every 180
days(6months).
⇒ It is suggested calibrate the sensor with the known
concentration standard gas if the detector for combustible gas
is exposed in any Catalytic pollutants or toxicant(such as
sulphide, Silicon vapor. halogen compounds, etc)
⇒If the read exceeds the range, the detected gas may reach
explosive or dangerous concentration.
⇒ If the read rises and reduces or the read does not keep
steady, it means there is a gas exceeding the detecting upper
limit and danger existing.
⇒Please don’t expose the detector to the environment which
has electric shock, strong magnetic field or serious continuous
mechanic shocking, Or it will influence the accuracy and
shorten the sensor life.
⇒ The maintenance and repair item will be shown on this
manual.
⇒If you have suggestion or comments about our products and
service, you can contact any time, and your comments is
valuable treasure for us.
Content

1. Presentation-----------------------------------------------------P1
2. Main Function and Technical Index-----------------------P1-3
2.1 Main function------------------------------------------P1-2
2.2 Technical index-----------------------------------------P2-3
3. Construction Illustration and Function--------------------P3-5
3.1 Construction illustration -------------------------------P3-4
3.2 Button function---------------------------------------------P5
3.3 Menu and remote controller------------------------------P5
4. The Operations------------------------------------------------P6-11
4.1 Turn on---------------------------------------------------P6
4.2 Turn off---------------------------------------------------P6-
4.3 Menu instruction--------------------------------------P6-11
5. Installation-------------------------------------------------P17-19
5.1 Installation position----------------------------------P17-18
5.2 Wire connection-------------------------------------P18-19
6. Sensor Module Replacement-------------------------------P20
7. Normal failure and solving----------------------------------P20
8. The spare parts------------------------------------------------P21
9. Attentions-------------------------------------------------- P21
1. Presentation-
The module gas detector( detector as below), it is a fixed
detector continuously monitoring the combustible gas,
toxic gas as well as oxygen. The detector works by
natural diffusion, adopts the imported electro-chemical
sensor for toxic gas and oxygen, catalytic sensor for
combustible gas, IR sensor and PID sensor, too. It has
good reproducibility and sensitivity, disturbing-proof
against temperature and humidity, long life-span and easy
operation.
The detector is with LED display screen showing the real
gas leakage concentration and once the gas leakage
concentration exceeds the preset alarm point (threshold) it will
start the acoustic-optical alarm on the central unit and drive the
external equipment like exhaust fans.
The signal output is standard 4-20mA or RS485. It is widely
used in refineries, petrol, chemistry, metallurgy, artifice, gas
transportation, biological medicine and water procession etc.

2. Main Function and Technical Index


2.1Main Function
 With the advanced inserted 16 digit low-power MCU
control.
 LED display screen(LCD display screen optional)
 User-selectable alarm setpoint(s).
 The sensor module can be replaced by the same type
sensor & other type sensor of different detecting range.
 The detector distinguishes the sensor module automatically,
no need to calibrate.
 Automatical calibration to decrease the error.
 Password verification for repeat operation, avoid fault
operations.
 4-20mA analog output(3+ channel) for direct
communication to DCS system, RS485 ModBus output
for central unit(optional)
2.2 Technical index
 Sensor type: original imported electro-chemical sensor or
catalytic combustion sensor.
 Gas sampling: Natural diffusion.
 Range: see the attached chart
 Resolution: 1% LEL,0.1%VOL, 1ppm or 0.1ppm
 Accuracy:<= + 5% F.S
 Response time:T90<30s.
 Condition display: LED display screen(LCD display
screen optional)
 Alarm tip: Super-bright alert indication.
 Alarm setpoint: The first alert point Can be set by user
The second alert point Can be set by user
 Operation: Infrared remote control.
 Power supply: DC24V+ - 15% (16~30V DC and
recommended voltage is DC24V. The voltage exceeding
DC 30V will damage the detector).
 Ambient Parameter: Temperature:-20℃~+60℃
High Temperature:10℃~180℃
 Humidity: < 90%(without condensating)
 Type of cable: 3 or 4 active wires screened between
detector and centralized unit. 3×1.5mm2 for 4-20mA
signal OR 4*1.5mm2 for RS485 signal, external
diameter ¢>=10mm
 Transmission Distance:<=1000meter
 Mounting Screw thread: G1/2, M20*1.5
 Weight: 1200g.
 Anti-explosion Class: Ex d IICT6Gb
 Protection Class:IP66.

Note: User can choose different function and spare parts.

3. Construction Illustration & Function


3.1 Construction Illustration
1.LCD display screen(optional)
2.LED display screen(optional)
3.Sensor module
4.remote controller
5.visual-audible alarm(optional)
6. Calibration cover
7.Protection cover
The detector consists of cast aluminum housing, stainless steel
sensor breathing device,, sensor module block, main control
module, digital communication module, protection cover and
calibration cover.
3.2 Button Function
Up button
Increasing button for number
Down button
Move button for number inputting
Confirmation button
In detecting state, press the confirmation button for
3s and then input the password “1111” to the menu
display.
The detector returns to normal detecting state automatically
when no operation for 10s.
3.3 The contract of remote controller operation and
detector menu
In the normal detecting mode, press confirm button “ ”3
seconds to menu. The menu items are 1-9 as below:
1. = escape
2. = Low alarm set
3. = Hysteresis error of low alarm
4. = High alarm set
5. = Hysteresis error of high alarm
6. =Zero calibration
7. = Range calibration
8. =Address code
9. =Baud rate setting
10.IO Zero: = the proofread of output signal
4mA
11.IO Range: the proofread of output signal
20mA.

4. The operation instruction

4.1 Turn on
The detector enters into normal detecting mode after it
is electrified and the 10s self-test countdown
finishes.When the read keeps steady, the read on the main
display window is the detected gas concentration.(It takes
different time for different gases to keep the read steady,
normal period is 2-5 minutes).
The detector is set with the standard value and quality
checked OK when it is ex-factory. If there is no special
requirement of the setting value, the detector can work
directly without any operation on the settings. Range
calibration is forbidden without the standard calibration
gas.
4.2 Turn off
In detecting mode, The detector turns off by powering
off.
4.3 Menu Instruction
In normal detecting mode, press confirmation button
“ ”3seconds or press the “menu”on the remote controller,
the display screen will show “ ”. Input the password
“1111” and then press confirmation button “ ”.The menu
items showing as below:
1. escape
2. baud rate 600 1200 2400 4800 9600
3. address code 001~127
4. Range calibration
5. Zero calibration
6. Hysteresis error of high alarm
7. High Alarm
8. Hysteresis error of low alarm
9. --Low alarm
In normal detecting mode, press UP button “ ”3seconds
or press the “F1”on the remote controller, the display
screen will show “ ”. Input the password “3088” and
then press confirmation button “ ”.The menu items
showing as below::
10. -escape
11. --reset (recover the ex-factory setting.)
12. The proofread of DA output 20mA.
13. The proofread of DA output 4mA.
4.3.1 Baud rate Set
Upon the menu instruction and choose “ ”baud rate set
menu, then press confirmation button “ ”to baud rate
value “e.g 9600”. Change the baud rate value by UP
and Down button, and confirmation button “ ”to
confirm. When the baud rate value is set successfully,
back to the baud rate menu. Press Up and Down
button till menu appears, finally exit by
confirmation button“ ”.
4.3.2 The Communication Address Set
Choose address set menu and press confirmation
button till the screen display address “e.g 0001”. Change the
communication address by UP and Down button,
and confirmation button “ ”to confirm.
4.3.3 Range Calibration
First, connect the calibration cover and sensor breathi ng
device. Put the standard calibration gas with known
concentration into the device, the calibration gas flux of
350ml---400ml is suggested. Second, press confirmation
button 3seconds or “menu” on the remote controller. It
displays“ ”, input the password “1111”and then press
Confirmation button to menu: choose calibration menu
by Up and Down button, and then press
confirmation button It displays calibration value e.g
“0200”. Revise the calibration value as the standard calibration
gas value by UP and Down button. Press “Confirmation
” button to remember this figure and calibrate it. 15s
countdown displays and the detector returns to normal status.
Note: 1. Please don’t carry the calibration when the detector is
working or there is no calibration gas.
2. The calibration can be repeated till the value steady.
4.3.4 Zero Calibration
Upon the menu instruction, choose Zero calibration menu
“ ” by Up and Down button. Press the
confirmation button and it displays “0000”, again press
the confirmation button , when the 10s countdown on
the screen finishes, the detector returns to the normal
status.
Notes: 1) Zero calibration must be done in the clean air. It
is forbidden to do zero calibration when the target gas
exists in the working place.
2) For O2 or N2 gas detector, the detector should be put
into pure N2 gas environment).
4.3.5 Hysteresis error of high alarm
Upon the menu instruction to choose “ ” Hysteresis
error of high alarm menu by Up and Down button.
Press the confirmation button and it displays
Hysteresis error value of high alarm “e.g 0003”. To revise
the value by Up and Down button. Then press
confirmation button to remember this figure and press
confirmation button to normal status.
4.3.6 High alarm setting
Upon the menu instruction, choose High alarm menu
“ ” by Up and Down button. Press the
confirmation button and it displays high alarm value,
“e.g 0150”. To revise the value by , Up and Down
button. press confirmation button to save this figure and
press confirmation button to normal status.
4.3.7 Hysteresis error of Low alarm
Upon the menu instruction, choose Hysteresis error of low
alarm menu “ ” by Up and Down button. Press
the confirmation button and it displays Hysteresis error
value of low alarm “e.g 0003”. To revise the value by
pressing Up and Down button. press confirmation
button to remember this figure and press confirmation
button to normal status.
4.3.8 Low alarm setting
Upon the menu instruction, choose Low alarm menu “ ”
by Up and Down button. Press the confirmation
button and it displays low alarm value, “e.g 0050”. To
revise the value by Up and Down button. press
confirmation button to save this figure and press
confirmation button to normal status.
4.3.9 Display Adjust
In the normal status, press Up button or “Display” button on
the remote controller, the screen displays the detector
parameter in sequence as below: low alarm value, Hysteresis
error value of low alarm, high alarm value, Hysteresis
error value of high alarm, calibration value, address code,
baud rate value, gas type, range.

4.3.10 Reset and 4-20mA calibration


In the normal status, press Up button or “F1” button on the
remote controller, the screen displays “ ”, input the
password “3088”. Then choose reset menu by Up
and Down button and confirmation button to
confirm. Back to menu by pressing Up and Down
button and press confirmation button to exit.
In the normal status, enter into the menu and choose
menu and press confirmation button to menu. To
calibrate the output 20mA by pressing Up and Down button
, confirmation button to confirm the calibration. Press
Up and Down button , till press confirmation
button to exit.
In the normal status, enter into the menu and choose
menu and press confirmation button to menu. To
calibrate the output 4mA by pressing Up and Down button
, confirmation button to confirm the calibration. Press
Up and Down button , till press confirmation
button to exit.
6. Installation & Wire Connection
6.1 Installation position
6.1.1The position should be within 1m around the possible gas
leakage area, such as valve, pipe connection point, gas outlet
place. Please try to install it nearer to the above places, but
avoid influencing the working of other equipments. Please
avoid the environment of high temperature and humidity. Also
please keep it from water swashing, oil and mechanical damage.
Please take the maintenance and calibration of the detector into
consideration.
6.1.2 For the gas, e.g CH4 etc which is lighter than the air, the
position is 2m~3.5m higher than the gas source. For the gas,
which is heavier than the air, the position is 0.36~0.6m higher
than the ground.
Note: Gas density more than 0.97kg/CBM, then it is heavier.
Gas density less than 0.97kg/CBM, then it is lighter.
6.1.3 Fix the detector with sensor head downwards. Screw
thread nut, bulge bolts and fix it tightly, and connect with cover
tightly to ensure the anti-explosion requirement.
6.1.4. For large scale detection, we suggest install 1pcs every
30-40 square meters, so as to get the best detection result.
6.2 Wire connection
Notes:1) Wire connection should be carried when power off.
2)The diameter of the wire between the controller and
detector should be no less than 1.5 square millimeter and the
distance should be no more than 1000m, RVVP wire is
required.
6.2.1 Screw off the cover in counter-clockwise. Then use a
screw to screw off the bolts and take off the display PCB.
6.2.2 Screw off the connector and take out the explosion-proof
pad, Then put 3-line wire to the internal of the enclosure
through the connector, compaction circle, air-proof closing
plug and the wire connection hole. For anti-explosion
requirement, please do not take out the explosion-proof closing
plug from the unused wire connection holes and do not throw
away any part inside the enclosure or the PCB.
Connect the wires to the terminals as the following picture
shows.
6.2.3 After the correct wire connection, take out the useless
wire from the enclosure. Then tighten the screw nut, tighten
rubber air-proof circle and wire. Anti-explosion soft tube can
also be connected with the device directly (Please check if the
screw of the soft tube and detector is the same).
6.2.4 After checking all the connection well, install the display
PCB and the front cover. Make sure O-type circle is put on and
connected with cover tightly.
The wire connection between controller and detector
figure:
7.Sensor maintenance and replacement

The detector adopts sensor module design, the life of


catalytic sensor is 3~5 years and electrochemical sensor
for oxygen is 1~2 years, other electrochemical sensor is
2~3 years. When the sensor life is overdue, the detection
result may be not accurate. Please contact the seller for
replacing the sensor. It is suggested to calibrate the
sensor once every 6 months to keep the accuracy.

8. Normal problem and solution


Fault Possible Reason Solution
Contact the seller or factory
Electric circuit fault
No for repair
response to the
Warm up is too short Prolong the warm-up period
gas
Sensor overdue Replace it with a new one
strong magnetic Clear or keep away from
Zero
disturb the strong magnetic
calibration can
Calibrate in time or replace
not work Sensor swift too much
the sensor
Lack or unconnected Check the sensor module
Err1
with sensor and connect it tightly

Senor Zero swift Carry the zero


Err2
too much calibration in the clean air.
9. The spare parts
There are a gas detector,1pc calibration cover, 1 instruction
manual, 1 certificate of quality and 1 maintenance card.

10. Attentions
1. Avoid being fallen from high places and vibrated mightily.
2. Keep the detector away from the place where is rapid air
flow. Otherwise it will influence the testing result.
3. Before using this product, please read the following
instruction carefully and adhere to related requirement strictly.
4. It is forbidden to use the detector in the places where is
corrosive gas and other severe conditions with exorbitant or
over-low temperate, high humidity, electromagnetism
environment and strong sunshine.
Please clean the detector with soft cloth in case there is dirt on
the appearance for long usage. Don’t clean with corrosive
solvent or hard materials, which may hurt and break the
appearance of the detector.
Please re-calibrate the sensor once every 6 months. It’s
suggested to test or inspect the detector frequently, so as to
avoid any dust or unexpected painting on the sensor.
Any application and failure not mentioned in this instruction,
please contact us for solving.
The reference chart for gas detector choice

For the gas not covered here, please don’t hesitate to contact
us.