You are on page 1of 1

Technical Specification for Klippon Galvalume Steel Profile Sheets

# Particulars Parameter Technical Details


1 Base Cold rolled steel Cold rolled steel confirming to IS:513-2008
Material
Yield Stress Min. 275 Mpa (Testing as per IS:1608-2005)
Base Metal Thickness 0.50 mm (Testing as per ASTM/SRTL/SOP/MECH-11)
2 Coating / Hot dip metallic Steel surface shall have hot dip metallic coating of Al-Zinc alloy
Painting on Coating comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as
Base Metal per the ASTM-A792M. The steel have organic coating with
Silicon Modified Polyester (SMP) paint on continues coil coating
line.
Coating Mass Total mass of the coating on both sides shall be 150 gms / sqm.
(Total on both sides as determined by triple spot tests).
Top Side painting 20-25 Microns
thickness i.e. 15-18 microns Silicon Modified Polyester (SMP) paint, over
5-7 microns epoxy primer
Back side painting 8-10 Microns
thickness i.e. Silicon Modified Polyester (SMP) paint, over epoxy primer
3 Total Coated Total Coated 0.58 MM
Thickness Thickness (TCT) (As per IS : 15965)
(TCT)
4 Protective Thickness Min. 25 Micron
guard film

Other Details:

# Parameter Details
5 Size of sheet / 6000 mm Long x 475 mm wide overall. (Cover width 406 mm to 550 mm)
Profile
6 Roofing dimensions Roofing shall be approx. 6.20 Kgs/sqmtr.
Recommended span for wind load as per IS-875-1993
Roofing sheets according to the site requirement. The overall profile width of the
sheet is 400 to 550 mm
7 Method of Laying of The sheets are to be fastened to roof purlins with the help of special type of fixing
sheets clips and self drilling Zinc coating fasteners of 12x25 mm size. These sheets do
not required any fastening holes through the sheets. The two fasteners are
inserted only through the two punched holes. Four dimples are also provided in
clip but there are not for auxiliary fasteners but for provided strength to the clip
only. The clip has a short return leg & a long return leg. The clip must be
positioned with the short leg engaging over the female rib of under lapping sheet.
The supply of sheets shall be factory cut in required length as per the site
requirement.

8 Ridge Capping / Ridges / Flashing will be supplied in required width of the similar roof material up
Flashing to a length of 2500 mm and will be fixed with the help of self drilling. Zinc coated
fasteners of size 12x25mm at a max of 500 mm centre to centre gap in length.