DESIGN SUMMARY

TANK GEOMETRY DETAILS


TANK DIAMETER 80 ft
TANK HEIGHT 50.75 ft TANK SHELL PLATE DATA
DESIGN BASIS SHELL THICKNESS WIDTH MATERIAL WEIGHT
(in) (in) (lbs)
CODES/STANDARDS API 650 12TH ED. ADD. 3
RING 1 0.39 119 A36 39670
APPENDIX/ANNEX E
RING 2 Š 119 A36 31803
CUSTOMER SPEC
RING 3 Š 95 A36 25389
PRODUCT ETHANOL STAIRWAY
RING 4 ‚ 95 A36 20311 PLATFORM
MAXIMUM CAPACITY 42675 bbl ‚ THK
RING 5 ‚ 95 A36 20311
(FROM BOTTOM TO DESIGN LIQUID LEVEL ROOF ROOF PL

2'-6Š
RING 6 ‚ 83 A36 17746
SPIRAL TOP ANGLE (TOE OUT)
NET WORKING CAPACITY 40362 bbl STAIRWAY HANDRAIL 12 3 X 3 X…
(FROM LOW OPERATING LEVEL TO HIGH OPERATING LEVEL)
ƒ
DESIGN LIQUID LEVEL Hd = 47.667 ft
HIGH OPERATING LEVEL 47.667 ft
LOW OPERATING LEVEL 2.5833 ft
BOTTOM SLOPE CONE-UP 0.1 in/ft DLL= HLL= 47'-8 ROOF RAFTERS
ROOF TYPE COLUMN-SUPPORTED CONE ROOF (36) W8X18 ‚ THK RING NO. 6
ROOF SLOPE 3.576 deg

16'-5‡
MAX. DESIGN TEMP 120 F
DESIGN MET. TEMP 50 F
DESIGN SPECIFIC GRAVITY Gd= 0.8 ‚ THK RING NO. 5
TEST SPECIFIC GRAVITY Gt= 1.0
DESIGN PRESSURE Pd= ATMOSPHERIC
TOTAL SHELL WEIGHT = 155230
DESIGN VACUUM Pv= 0.036 psi

SHELL HEIGHT = 50'-9


WORKING CAPACITY
OPERATING PRESSURE ATMOSPHERIC psi
TEST PRESSURE Pt= ATMOSPHERIC psi
TANK ROOF AND BOTTOM PLATE DATA ‚ THK RING NO. 4
L6X6X…
OPERATING VACUUM 0.014 psi ITEM THICKNESS WIDTH JOINT TYPE MATERIAL WEIGHT

40362 bbl
WIND CODE ASCE 7-05 (in) (in) (lbs) CENTER COLUMN
WIND PARAMETERS 135 mph, Exp C, I: 1.0 BOTTOM ‚ 96 SLW A36 52805 16 DIA SCH 10
ROOF LIVE LOAD LL= 20 psf ROOF PLATE ‚ 96 SLW A36 52448 Š THK RING NO. 3
SNOW LOAD CODE API 650

NET
ROOF SNOW LOAD SN= 0 psf
SEISMIC CODE API 650 ANNEX E TANK STRUCTURAL DATA
SEISMIC PARAMETERS MAPPED ASCE 7 METHOD
ITEM DESCRIPTION MATERIAL WEIGHT
SUG: I, SITE CLASS: D, Av: 0.193 Š THK RING NO. 2
(lbs)
Ss:0.42, S1:0.20, TL:4.00
TOP ANGLE L 3 X 3 X… A36 1809
% SNOW LOAD USED IN SEISMIC 10 %
SHELL STIFFENERS L 6 X 6 X… A36 3753
SHELL JOINT EFF. e= 1.0
COLUMN 16 SCH 10 A53-B 2095
RADIOGRAPHY PER API 650 12TH EDITION ALUMINUM INTERNAL
ROOF RAFTER (36) W8X18 A992 23513
PWHT NONE FLOATING ROOF
0.390 THK RING NO. 1
PUMP IN RATE 4000 bph
LLL= 2'-7
PUMP OUT RATE 4000 bph TOP OF BOTTOM
INSULATION-SHELL NONE PLATE
INSULATION-ROOF NONE 1
CORROSION ALLOWANCE
4 ‚ THK
120 BOTTOM CROWN
SHELL 0 in
BOTTOM PL
AT CENTER
ROOF ˆ in
BOTTOM 0 in
TANK VENTING DATA
NOZZLES 0 in VENT TYPE QTY. SIZE MODEL MANUF. SET PRESS 80'-0 CENTERLINE DIAMETER
INTERNALS 0 in (in) NO. (in W.C.)
STRUCTURAL ˆ in, 1 SIDE OF WEB & FLG CIRCULATION VENT 8 20 G18 TBD N/A TANK SKETCH
COLUMN ˆ in, OUTSIDE MUSHROOM VENT 1 12 G2 CBI N/A

MISCELLANEOUS ITEMS
DESCRIPTION/SIZE
FLUSH COD NONE
TANK ACCESS SPIRAL STAIRWAY
FOAM SYSTEM YES - BY OTHERS
DELUGE SYSTEM NONE

LIQUID LEVEL ABBREVIATIONS:


DLL = DESIGN LIQUID LEVEL
HLL = HIGH LIQUID LEVEL (HIGH OPERATING LEVEL)

PRELIMINARY

REMARKS
ROOF
LLL = LOW LIQUID LEVEL (LOW OPERATING LEVEL)
TANK DESIGN SUMMARY

TO
ETHANOL TANK

ADDED
(1) 80'-0 DIA X 50'-9 HIGH CRT W/ AIFR

ISSUED
ADDITIONAL INFORMATION: WEST INDIES PETROLEUM

CA
IP IP PORT ESQUIVEL, JAMAICA

AJH

AJH
BY AJH CHKD DATE CONTRACT NO

REVISIONS
PHE/ R. LARRY MOFFATT 245987

A
ENGINEERING ASSIGNED
DWG NO SHT NO REV

DATE
DATE

CHKD

CHKD

DATE
CHKD
BY

BY
BY
DOC NO. 245987-000-PS-01-000100 1 0 B
THIS DOCUMENT IS THE PROPERTY OF CHICAGO BRIDGE & IRON COMPANY ("CB&I"). IT MAY CONTAIN INFORMATION DESCRIBING TECHNOLOGY OWNED BY