0316

Refer to ASHRAE - 1992 Systems and Equipment handbook 31.7


Gas density 0.706 kg/m³
Gas temperature 237.0 °C
Ambient pressure 101.2 kPa
Ambient temperature 25.0 °C
Altitude 8 m
Air density 0.859 kg/m³

Gas pressure drop losses...


__________________________________________________
Gas velocity Estimated pressure drop
[m/s] [Pa]
__________________________________________________
6.0 83.4
6.5 97.9
7.0 113.5
7.5 130.3
8.0 148.3
8.5 167.4
9.0 187.7
9.5 209.1
10.0 231.7
10.5 255.4
11.0 280.3
11.5 306.4
12.0 333.6
12.5 362.0
13.0 391.5
13.5 422.2
14.0 454.1
14.5 487.1
15.0 521.3
__________________________________________________

Chimney pressure drop at actual design flow of 15.0 m³/s


Cone exit velocity 23.6 m/s
Inlet velocity 11.6 m/s
__________________________________________________
Gas velocity Section pressure drop
[m/s] [Pa]
__________________________________________________
9.1 0.0
9.1 43.1
9.1 1.6
12.2 5.8
17.3 8.0
17.3 8.0
17.3 8.0
17.3 8.0
17.3 8.0
17.3 8.0
17.3 8.0
0585 - 25TPH CFWTB - Clover Queensburg Prepared By Leonine International Inc Page 1, Next page 2
0316
17.8 21.1
18.3 9.2
19.5 50.4
__________________________________________________
Top cone pressure loss 26.7 Pa
Inlet pressure loss 43.1 Pa
Natural draft 0.0 Pa
Chimney friction loss 117.4 Pa
Stack Total DP 187.2 Pa

Top exit velocity pressure 196.2 Pa

Notes
[1] The effect of gas cooling on the pressure drop has been ignored.
[2] It is correct that the kinetic energy of of the flue gas at
the exit is lost, the pressure caused by the acceleration up
to the outlet velocity is generated in the system
upstream of the chimney.

0585 - 25TPH CFWTB - Clover Queensburg Prepared By Leonine International Inc Page 2, Report end.