PERFORMANCE RESULTS

Minimum

Case - 2

Case - 3

Case - 5

Case - 6
Design
Part Load % of MCR 25 100
Blow down (intermittent) % steam 5 5
Excess air % 99.54 40
Ambient air relative humidity % 61.4 61.4
Flue gas recirculation % 25 25
FLOW RATES
Steam, boiler outlet kg/hour 6,250 25,000
Blow down- intermittent kg/hour 313 1,250
Deaerator steam kg/hour 439 1,758
Feed water kg/hour 34,125 34,125
Makeup water kg/hour 1,649 6,595
Condensate return total kg/hour 4,474 17,897
Combustion air (wet) kg/hour 13,457 40,648
Ash kg/hour 171 737
Products of combustion kg/hour 13,731 42,509
Fuel kg/hour 793 3,414
Steam leaving superheater
PRESSURES
MSSNRV output kPag 2,300 2,300
Boiler side pressure drop

TEMPERATURES
Feed water supply °C 104 104
Ambient dry bulb °C 29 29
Flue gas exit °C 1,186 1,829
Economizer exit feed °C 131 146
Stack exhaust, flue gas recirculation

HEAT DUTY
Heat input kWth 5,307 22,848
Heat ouput (steam) kWth 4,309 17,236

THERMAL EFFICIENCY
Efficiency- gross % 81.19 75.44
Efficiency- net % 84.37 78.39
-dry flue gas loss % 5.94 13.91
-fuel water vapor loss % 4.3 4.69
-air water vapor loss % 0.18 0.43
-winter ice loss % 0.14 0.13
-unburned gas loss % 0 0
-bottom ash loss % 4.89 4.55
-fly ash loss % 0.12 0.11
-Radiation & unaccounted loss % 3.24 0.75
-manufacturers margin % 0 0
-total losses % 18.81 24.56

PRODUCTS OF COMBUSTION
Argon % v/v 0.88 0.87
Carbon monoxide % v/v 0 0
Carbon dioxide % v/v 8.88 12.52
Moisture % v/v 5.96 7.36
Nitrogen % v/v 74.31 73.59
Oxygen % v/v 9.93 5.63
Sulfur dioxide % v/v 0.02 0.03

PRESSURE LOSS
Furnace Pa 150 150.1
Screen tubes Pa 0 0
Evaporator bank- 1 Pa 30.2 337.2
Evaporator bank- 2 Pa 22.6 244.3
Evaporator bank- 3 Pa 6.6 67.7
Economizer Pa 14.5 142.5
Duct Pa 19.4 5.3
Damper Pa 42 42
Chimney Stack Pa 14.6 194.1